Manual Flo-tap Installation Instructions

22
Manual Flo-tap Installation Instructions Quick Installation Guides: 00825-0400-4809 rev. EA – 485 Flanged Flo-tap 00825-0500-4809 rev. DB – 485 Threaded Flo-tap

description

Manual Flo-tap Installation Instructions. Quick Installation Guides: 00825-0400-4809 rev. EA – 485 Flanged Flo-tap 00825-0500-4809 rev. DB – 485 Threaded Flo-tap. Nomenclature. Top Plate. Instrument Connections. Full Insertion Marking Nut. Support Plate. - PowerPoint PPT Presentation

Transcript of Manual Flo-tap Installation Instructions

Page 1: Manual Flo-tap Installation Instructions

Manual Flo-tap Installation InstructionsQuick Installation Guides:00825-0400-4809 rev. EA – 485 Flanged Flo-tap00825-0500-4809 rev. DB – 485 Threaded Flo-tap

Page 2: Manual Flo-tap Installation Instructions

Nomenclature

Support Plate

Top Plate

Head Plate Lock Nut (Retraction Drive Nuts)

Instrument Connections

Insertion Rods

Full Port Isolation Valve

Full Insertion Marking Nut

Insertion Drive Nuts

Page 3: Manual Flo-tap Installation Instructions

Weld the Mounting Hardware Onto the Pipe

Threaded Flo-tap Flanged Flo-tap

Page 4: Manual Flo-tap Installation Instructions

Tack Weld the Mounting Hardware with 4 Equal Length Tacks Tack weld anywhere on

the mounting hardware Then again directly across

from the first tack weld Then on the other 2 sides

2

1

3

Page 5: Manual Flo-tap Installation Instructions

Check to See that the Mounting Hardware is Level and Square If it’s not, use a

rubber mallet to lightly adjust the hardware and recheck

Page 6: Manual Flo-tap Installation Instructions

Verify that the ODF Dimension Matches What is Listed in the QIG The ODF is the dimension from outside pipe diameter to face of flange

485

Page 7: Manual Flo-tap Installation Instructions

Verify that the ODF Dimension Matches What is Listed in the QIG The ODF is the dimension from outside pipe diameter to face of flange

For Threaded Flo-tap the dimension from the pipe OD to the top of the threadolet is called LMH:485 Sensor Size 1: 1.38-in. (35 mm)485 Sensor Size 2: 1.56-in. (40 mm)485 Sensor Size 3: 2.06-in. (52 mm)

Page 8: Manual Flo-tap Installation Instructions

Complete a Continuous Weld Around the Perimeter of the Unit

Page 9: Manual Flo-tap Installation Instructions

Attached the Full Port Valve to the Mounting HardwareThreaded Flo-tapFirst, thread the guide nipple into the mounting then thread the valve

Flanged Flo-tap

The valve stem should be in-line with the pipe so it will not interfere with the insertion rods

The valve must be a full port valve to allow the Annubar to pass through the valve into the pipe

ODV

Page 10: Manual Flo-tap Installation Instructions

Verify the ODV DimensionThe ODV is the dimension from the outer diameter of the pipe to the top of the valveFlo-tap / Flange Rating 485 Sensor Size 585 Sensor Size ODV Dimension

Threaded1 --- 7.51-in. (190.9 mm)

2 --- 8.17-in. (207.5 mm)

ANSI 150 # 1 11 10.5-in. (266.7 mm)

ANSI 300 # 1 11 11.75-in. (298.5 mm)

ANSI 600# 1 11 14.06-in. (357.2 mm)

ANSI 150 # 2 22 11.25-in. (285.8 mm)

ANSI 300 # 2 22 13.00-in. (330.2 mm)

ANSI 600# 2 22 16.38-in. (416.0 mm)

ANSI 150 # 3 44 12.75-in. (323.9 mm)

ANSI 300 # 3 44 16.25-in. (412.8 mm)

ANSI 600# 3 44 19.50-in. (495.3 mm)

Page 11: Manual Flo-tap Installation Instructions

Drill the Hole by Using a Hot Tap Drilling Machine

Tag with correct drill hole size attached to the Annubar

Guide Ring in Rosemount Supplied Mounting Hardware

Page 12: Manual Flo-tap Installation Instructions

After the Hole is Drilled, Retract the Drill Past the Valve and Close the ValveVent drilling machine and remove the per manufacturers

and site proceduresThreaded Flo-tap Flanged Flo-tap

Remember that the hot tap drilling machine is under pressure and exposed to the process fluid

Page 13: Manual Flo-tap Installation Instructions

Attach the Fully Retracted Flo-tap Assembly to the Valve

Threaded Flo-tap

Page 14: Manual Flo-tap Installation Instructions

Attach the Fully Retracted Flo-tap Assembly to the Valve

Flanged Flo-tap – Use a hoist strap and crane if needed

Page 15: Manual Flo-tap Installation Instructions

Quickly Open and Close the Valve to Pressurize the Annubar, Check for Leaks

Page 16: Manual Flo-tap Installation Instructions

If Leaks are Present, Tighten the Packing Gland Nuts

Page 17: Manual Flo-tap Installation Instructions

Loosen the Insertion Limiting Nuts

Page 18: Manual Flo-tap Installation Instructions

Simultaneously Tighten the Insertion Drive Nuts to Insert the Annubar

Page 19: Manual Flo-tap Installation Instructions

Lower the Head Plate Lock and Full Insertion Marking Nuts to the Head Plate

Head Plate Lock Nut

Full Insertion Marking Nuts

Page 20: Manual Flo-tap Installation Instructions

To Retract the Annubar – Loosen the Retraction Limiting Nuts

Retraction Limiting Nuts (Same as Insertion Drive Nuts)

Page 21: Manual Flo-tap Installation Instructions

Loosen the Retraction Drive Nuts to Retract the Annubar

Page 22: Manual Flo-tap Installation Instructions

Other Installation Considerations During insertion, the rods can twist and the top

plate and support can come out of alignment.– Makes insertion difficult– Hit the top plate with a rubber to put them back in-line