Product Data Document 225DS-25h / D301300X012 April 2011 - Page 1 Website: www.EmersonProcess.com/Remote Remote Automation Solutions Bristol ® 3808 MVT Multivariable Transmitter Model 3808-30A With DP/P/T Variables Featuring: Now featuring 4000 psi pressure range Excellent measurement performance over the full range of operating pressure and temperature conditions Extremely low power consumption—perfect for remote sites with battery and solar power systems “Bilingual” Networking via BSAP and Modbus protocols with RS 485 interface Two versions: RS485 with RS232 port for configuration or Analog Output with FSK signal Intrinsically safe and explosion proof for operation in Class I Division 1 hazardous areas Bidirectional DP measurement DP/P “wet end” sensor assembly is independent of the “top end” assembly Introduction The Bristol® 3808 MVT is Emerson Process Man- agement’s answer to industry demands for a trans- mitter with high reliability, high performance over real world pressure and temperature conditions, ease in use, “networkability” and very low power consumption. The 3808 MVT has been designed to provide the highest value in terms of all user consid- erations, including purchasing, installation, opera- tion and maintenance. To maximize measurement accuracy, the 3808 com- bines a wet end with a low reference uncertainty of 0.075% URL, with a design that minimizes effects of pressure and temperature over the full range of operating conditions. For remote sites such as those in the energy and The Bristol® 3808 MVT Multivariable Trans- mitter features accurate measurement of DP, gauge pressure and temperature. water industries, power consumption has been a key consideration. Costs of batteries and solar panels are proportional to current draw and many users are surprised at the capital expenses associ- ated with electronics, which have not been designed to conserve power. The sophisticated design employed by the 3808 MVT keeps current draw well below 2 mA and with a power source as low as 5 Vdc. For remote sites, power budgeting is often very tight. Since the power consumption is so low, the 3808 MVT can even be added to existing sites, which were designed with no extra capacity for power. While the Bristol Synchronous and Asynchronous (BSAP) protocol ensures compatibility with Emerson measurement and SCADA systems, Modbus pro- vides compatibility with a wide variety of controllers, flow computers, RTU devices and SCADA systems from numerous suppliers.

description

Manual para configuracion de RTU

Transcript of Manual de Bristol

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 1

    Website: www.EmersonProcess.com/Remote

    Remote Automation Solutions

    Bristol 3808 MVT Multivariable TransmitterModel 3808-30A With DP/P/T Variables

    Featuring:Now featuring 4000 psi pressure range

    Excellent measurement performance over the full range of operating pressure and temperature conditions

    Extremely low power consumptionperfect for remote sites with battery and solar power systems

    Bilingual Networking via BSAP and Modbus protocols with RS 485 interface

    Two versions: RS485 with RS232 port for configurationorAnalogOutputwithFSKsignal

    Intrinsically safe and explosion proof for operation in Class I Division 1 hazardous areas

    Bidirectional DP measurement

    DP/P wet end sensor assembly is independent of the top end assembly

    Introduction

    The Bristol 3808 MVT is Emerson Process Man-agements answer to industry demands for a trans-mitter with high reliability, high performance over real world pressure and temperature conditions, ease in use, networkability and very low power consumption. The 3808 MVT has been designed to provide the highest value in terms of all user consid-erations, including purchasing, installation, opera-tion and maintenance.

    To maximize measurement accuracy, the 3808 com-bines a wet end with a low reference uncertainty of 0.075% URL, with a design that minimizes effects of pressure and temperature over the full range of operating conditions.

    Forremotesitessuchasthoseintheenergyand

    The Bristol 3808 MVT Multivariable Trans-mitter features accurate measurement of

    DP, gauge pressure and temperature.

    water industries, power consumption has been a key consideration. Costs of batteries and solar panels are proportional to current draw and many users are surprised at the capital expenses associ-ated with electronics, which have not been designed to conserve power. The sophisticated design employed by the 3808 MVT keeps current draw well below 2 mA and with a power source as low as 5 Vdc.

    Forremotesites,powerbudgetingisoftenverytight. Since the power consumption is so low, the 3808 MVT can even be added to existing sites, which were designed with no extra capacity for power.

    While the Bristol Synchronous and Asynchronous (BSAP) protocol ensures compatibility with Emerson measurement and SCADA systems, Modbus pro-vides compatibility with a wide variety of controllers, flowcomputers,RTUdevicesandSCADAsystemsfrom numerous suppliers.

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 2 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Functionality OverviewEmersons Bristol 3808 MVT provides the following basic operations:

    Conversion of sensor readings from the wet end DP/P sensor assembly into accurate floatingpointpressurevaluesforDPandP.Conversion calculations utilize correction coefficientscontainedinthesensorassemblyand are performed once per second for each process variable

    Conversion of raw readings from an on-board A/DintoanaccuratefloatingpointRTDvalue.RTD conversions are performed once per second

    Up to 19200 baud, 2-wire RS-485 serial communicationsinterface,ora1200baud,FSKmodem interface via the 4-20ma current loop for Network communication

    Local RS-232 serial communications interface fixedat19200baud.(ConnectingtotheRS-232communications interface disables the RS-485 communications

    A subset of the Emerson BSAP RDB and Peer-to-Peer communications interface:

    CompletesetofUser/HostInterfacefunctionsforConfiguration,Calibration,and Data Collection

    Floatingpointvaluesreturnedindividually,orinpre-definedLists

    FloatingpointvaluesavailableforDP/GP,SP, T, Sensor Temperature, and Error Status

    Floatingpoint,Logical,orStringvaluesalso available for other ST3808 user configurationparameters

    Optional,4-to-20mAAnalogOutput:

    LinearorSquareRootMode

    ReversibleOutputAction

    MaybecontrolledexternallytoprovidearemoteAO

    Optional,on-boardLCDdisplaywithDP,PandT information

    Physical Overview

    Service:Flow,level,pressure,temperaturemea-surementsforliquidsandgases.

    DiaphragmMaterial:316SSorHastelloyC

    FlangeMaterial:316SSorHastelloyC

    FlangeBoltMaterial:316SS

    FillMedia:DC200SiliconeOil

    ProcessConnections:NPTonflanges1/2NPTwith connection blocks.

    Electrical Connections: NPT Conduit Connection

    Housing:LowCopperAluminumwithepoxypaintNEMA 4X explosion proof.

    Local indication: 4--Digit LCD display linear or squarerootinengineeringunits.

    RTD sensor: 3-wire platinum 100-ohm per DIN 43760 25 feet max.

    User connections: 10-terminal (2-rows) tri-barrier strip for + power, -power, RTD +, RTD-, RTD-, TXD, and RXD.

    Power Supply Information

    OperatingVoltageRange:542Vdc

    Current Draw:

    With RS 485: Less than 2 mA (typically 900 mA)

    WithFSK,butwith420mAoutputdisabled:Lessthan 3.2 mA

    Turn-on time:

    Measuredinputvariableswillbewithinspecifica-tions less than two seconds after power is applied to the 3808 MVT.

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 3 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Accuracy and Performance Specfications

    Allspecificationsareforthedigital,floating-pointsignal.

    Differential Pressure and Static Pressure

    Combined effects of nonlinearity, nonrepeatability and hysteresis at reference pressure and over the operating temperature range:

    DP and SP linear mode: 0.075% of Calibrated Span or 0.015% of URL, whichever is greater. 0.035% of span or 0.015% of URL for 1000 psi static pressure only, whichever is greater.

    Temperature effect on Static and Differential pres-sure:

    0.21%URL maximum combined shift of zero and span with an ambient temperature change of 60C (108F).0.17%URLmax.for1000psistaticpres-sure range.

    StaticPressureEffectsOnDifferentialPressure:

    Zero error: 0.1% URL, for a change in static pres-sure of 1000 psi

    Span error: 0.1% reading, for a change in static pressure of 1000 psi

    Long Term Stability at Constant Conditions:

    0.1% URL/Year typical

    Mountingpositioneffect:2inH2Omaximum,which can be calibrated out.

    Ripple and noise: Per ISA 50.1 Section 4.6

    Process Temperature - RTD Interface

    A three-wire platinum RTD per DIN 43760 is sup-ported. The temperature, T, in degrees Celsius is calculated using the Resistance vs. Temperature Tables according to the DIN EN 60751 standard for ClassA&BRTDs.TheDINEN60751equationis:

    R(t) = R0 * (1 + At +Bt2)

    Where:A = 3.9083 * 10-3 oC-1B = -5.775 * 10-7 oC-2Ro = 100ohms

    In addition, the user may enter the R0, A, and B coefficientsofacustomcalibratedRTD,anotherplatinum standard or a different material (Nickel, Balco or Copper). During the RTD calibration, the User will be able to set the R0,A,andBcoefficients,restorethefactorydefaultforthesecoefficients,andcalibrate the internal Reference resistor.

    Process Temperature Input Specifications (for the interface, only, not including the RTD probe or wiring)

    RTD Conversion Accuracy: 0.1C, or 0.1% of reading, whichever is greater

    Ambient temperature effect on RTD measurement:

    0.01C / C max

    Long Term Stability at Constant Conditions:

    0.25C / month max

    Analog Output Specifications

    Non-linearity: 0.1% max

    Temperatureeffects:+/-0.25%FullScaleover60degrees C.

    Environmental Specifications

    OverPressureLimit:Equaltothestaticpressureupper range limit (URL).

    Temperature limits:Wet End: -40 to +85CElectronics: -40 to +85CWith Display: -30 to +70CStorage Temperature: -40 to +100C

    Humiditylimits:Whencoversareproperlyinstalled,

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 4 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    unitwillwithstand0to100%RH(NEMA4Xenclo-sure)

    Vibration:0.1%URL/gmax10-500Hzinanyaxisper SAMA PMC-33-1C

    Electromagnetic compatibility:

    Conditions: Current output (only) twisted pair wires includes RTD. Covers installed and wiring run in groundedconduit.10V/M,20-500MHZperSAMAPMC-33-1C:

    DP and SP: 0.25%URLRTD Temperature: 1C

    Liquid Crystal Display (LCD)

    The LCD displays the measured variables for DP, P, and T. The display will continually cycle though all measured variables. The value and Engineer-ing Units for a particular variable will be displayed for three seconds. An annunciator indicates which pressure variable is being displayed.

    The LCD provides 4 1/2 digits of display precision with a decimal point. The following Engineering Units are included:

    C

    F

    BAR

    psi

    inH 2O@60F

    kg/cm 2

    kPa

    User Interface For The 3808 MVT

    Usingalap-toppersonalcomputer,fieldpersonnelcanquicklycalibrateandconfigurea3808MVTtransmitter. The personal computer interfaces to the RS 232 port. Meanwhile, the RS 485 port wiring need not be disconnected. RS 485 communication is disabled only while the PC cable is connected to the RS 232 terminals.

    Emersons LocalView Calibration Tool includes all calibrationandconfigurationoperations.Thistoolwill be familiar with users of Smartkit as well as all otherBristolflowcomputersandprovidesusersofall Bristol measurement products, from Emerson, a consistentandcompatibleHMI.

    A variety of User Interface features are provided by the 3808 MVT. These include:

    Set Communications Baud Rate

    Set BSAP Local Address

    SetBSAPGroupNumber

    Set Modbus Node Address

    Set Modbus Mode (ASCII/RTU)

    Enable/Disable Static Pressure Reading

    Enable/Disable RTD Temperature Reading

    ReadcurrentDP/GP,SP,T,SensorTemperature, and Status values

    ReadDP/GPandSPUpperRangeLimits

    CalibrateZero/SpanforDP/GPandSP

    Calibrate Zero for RTD

    ConfigureRTDCoefficients

    Configure4-20maAnalogOutput

    Enable/Disable

    SelectLinear/SquareRootMode

    SelectForward/ReverseActing

    SelectOutputVariable(DP/GP,SP,UserDefined,orNone)

    CalibrateZero/Span

    SelectEngineeringUnitsforDP/GP,SP,T

    SetFloatingPointDampingFactor

    Display Transmitter Information (Traceability information,RangeCodes,FirmwareRevision)

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 5 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Communication Interface

    BSAP Interface

    The 3808 MVT will act as an immediate response BSAP Slave device. The 3808 MVT will function as a terminal node only in a BSAP Network. BSAP Globalmessagesreceivedwiththe3808MVTsLocal Address will be processed by the 3808 MVT. Notethatpassthrough,orrouting,ofBSAPGlobalmessages, Expanded BSAP messages, and Time-Sync/Node Routing Table messages are not sup-ported.

    A subset of the RDB and Peer-to-peer messages are supported. This will provide the user both RDB and Peer-to-Peer List access to the 3808 MVT Pro-cess variables and parameters.

    MODBUS Interface

    The 3808 MVT will act as a Modbus compatible, slave device. The 3808 MVT provides support for both Modbus ASCII and Modbus Remote Terminal Unit (RTU) transmission modes, utilizing a subset of the Read/Write commands available via Modbus.

    To provide support for a variety of Modbus compat-ible host controllers, the 3808 MVT data available via Modbus are mapped into Modbus Coils/Regis-ters. To accommodate the different types of Modbus hostsavailable(i.e.standardModbus,ENRONModbus)floatingpointdataitemsaremappedtoseveral different Modbus Register address ranges. This provides both 16-bit and 32-bit register access using the appropriate register address and function code.

    Accessories

    EmersonsBristolOpenBSI/LocalViewCalibrationandconfigurationsoftwareforaPC

    CD part number: 395575-02-8

    PC-to-3808-MVTCableConnectstotheRS232 port on the 3808 MVT, 10 foot, part number: 396596-01-0

    TransmitterInterfaceUnit(TIU)Forcompatibilitywith the 3508, this module is used to connect a PC totheFSKsignalonthe3808MVT.

    Part Number 389959-01-4

    FortheTIU,pleasespecifythemodemcablelength:

    6footpartnumber390929-01-812footpartnumber390929-02-625footpartnumber390929-03-4

    Bendable RTD

    The user can select a bendable RTD that attaches to the transmitter via an armored cable of 6-foot, 15-foot or 25-foot length. The individual wires connect to terminations on the termination plate. The RTD assemblyalsoincludesafitting,whichisinstalledinthe conduit port.

    If ordered along with the transmitter, the bendable RTD assembly will be shipped in the same box as the transmitter.

    ThebendableRTDisaonesizefitsallsolutionthat is perfect for most applications and excellent for depot-level inventory situations in which the ultimate installation (and, therefore, thermowell depth) is not necessarily known.

    The12probecanquicklybeinsertedinathermowell, whereupon the user can tighten the in-cludedfittingtolockitinplaceandbendtheexcesslength out of the way.

    NotethatathermowellisrequiredforthisbendableRTD!

    Note also that the bendable RTD assembly is ap-proved only for use in Class I, Division 2 hazardous areas and is not explosion proof.

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 6 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Model Number: 3808-30A - A B C - D E F - G H J - K L M - N P Q R3808-30A X380830A

    DESCRIPTION CODEA B C Input Range Differential (inH2O) Static Pressure (PSI) A B C

    10 0-7.5 to 0-150 1000 1210-7.5 to 0-150 2000 1220-15 to 0-300 1000 1410-15 to 0-300 2000 1420-15 to 0-300 3000 1450-15 to 0-300 4000 1440-1.25 to 0-25 PSID 2000 2020-1.25 to 0-25 PSID 3000 2050-1.25 to 0-25 PSID 4000 204

    D Diaphragm Material D316 Stainless Steel 1

    20 HastelloyC 2 E Filling Media E30 DC 200 Silicone 1 F Flange Material X3808FLA F

    316 Stainless Steel Match D - diaphragm 140 HastelloyC material 2G Flange Vent Valve X3808VENT G

    None 050 With Vent Valve - 316 SS Note: Flange Material, F = 1 1

    WithVentValve-HastelloyC Note: Flange Material, F = 2 2H Manifold Adapter X3808MAN H

    None Match F - 0 60 Stainless Steel Flange 1

    HastelloyC Material 2J Comm / Output Options J 4-20mAcurrentoutput/FSK Note: Local calibration requires TIU. 1 70 RS 485 Note: Local calibration requires RS 232 cable. 2

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 7 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Model Number: 3808-30A - A B C - D E F - G H J - K L M - N P Q R3808-30A

    DESCRIPTION CODEK Local Indication X3808LIND K None 080 4 1/2 Digit LCD 1L Flange Orientation L

    Standard (faces away from front) 190 90 degrees (down) (Default) 2

    Note: Housing is very easy to rotate 180 degrees around in the field. M Mounting Bracket X3808MTG M

    None 0With"L"FlangedMounting Not avail. with 90 deg. (down) 1

    100 Bracket flange orientation (Option K=2)Neck Mounted Bracket With any Flange Orientation 2

    N Certification N110 UL/CULClassI,Division1,GroupsC&D;ClassI,Division2,GroupsA,B,C,D 1

    P Warning Plate PNone 0

    120 Russian 1Q RTD / Cable Assembly Q

    None Please refer to the notes, 0With RTD and 6-foot Cable below, concerning the RTD / 1

    125 With RTD and 15-foot Cable Cable Assemblies. 2With RTD and 25-foot Cable 3

    NOTES: RTD/CABLE ASSEMBLIESIf selected in "Q" above, the RTD/Cable assembly will be shipped in the same box as thetransmitter. Due to UL restrictions, they cannot be shipped "pre-connected."IMPORTANT:TheseparticularRTDassembliesarenotexplosion-proofbutareapprovedforClassI,Division2hazardousareas.Forexplosion-proofRTDcomponents,pleaserefer to "RTD Sensors and Related Accessories" in the Bristol price book.

    RFactory Configuration Options RUse the Standard, Defaults - Please DO NOT fill-in attachment 3800-A010 0

    130 SpecifyOtherConfigurationSettings-Please proceed to attachment 3800-A010. 1

    To specify a 3808 MVT that is approved by Industry Canada for custody transfer installations when used in conjunction with a ControlWaveEFMorControlWaveXFC,pleaseusethefollowingmodelnumberandattachmentnumber:

    3808-30A-142-111-102-020-1000 3808-B-1

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 8 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Attachment Number: 3800-A - AB - CD - E - F - GH - J - KL - M - N - P - R - T - U3800-A

    DESCRIPTION CODEA B DP Units for 3808-30A or GP units for 3808-10A A B

    InH2O(Default) Special Note for 25 PSI DP range: If you use 00PSI this attachment, "In H2O" become the default 01mmH2O units. If you want "PSI," you must specify 02ftH20 that, here. 03inHg 04mmHg 05

    90/160 KPa 06MPa 07BAR 08mBAR 09g/cm2 10kg/cm2 11

    C D SP Units for 3808-30A - Please note that this field is N/A for the 3808-10A CDInH2O 00PSI (Default) 01mmH2O 02ftH20 03inHg 04mmHg 05

    92/170 KPa 06MPa 07BAR 08mBAR 09g/cm2 10

    kg/cm2 11E Temperature Units for RTD Input E

    Degrees C (Default) 094/200 DegreesF 1

    F Communications Baud Rate F9600 (Default) 01200 1

    96/205 2400 24800 319,200 4

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 9 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Attachment Number: 3800-A - AB - CD - E - F - GH - J - KL - M - N - P - R - T - U3800-A

    DESCRIPTION CODEG H BSAP Local Address GH

    Using two digits, including a leading zero for 1 - 9, please specify the address in98/210 'GH,'ie."01"through"32."Forreference,thedefaultaddressis1.

    J BSAP Group Number J100/300 Pleasefill-inasingle-digitbetween1and8in'J.'Group1isthedefault.

    K L MODBUS Node Address KLUsing two digits, including a leading zero for 1 - 9, please specify the address in

    102/310 'GH,'e.g."01"through"32."Forreference,thedefaultaddressis1.M MODBUS Mode M

    ASCII (Default) 0104/320 RTU 1

    N ENABLE / DISABLE 4 - 20 mA Output NENABLE (Default) 0

    106/330 DISABLE 1P 4 - 20 mA LINEAR or SQUARE ROOT P

    LINEAR (Default) 0 108/340 SQUAREROOT 1

    R 4 - 20 mA FORWARD or REVERSE ACTING RFORWARD(Default) 0

    110/350 REVERSE 1 T 4 - 20 mA OUTPUT VARIABLE T

    DP(in3808-30A)orGP(in3808-10A)(Default) 0112/360 SP (3808-30A only) 1

    TEMPERATURE 2U RTS DELAY U

    10 ms Bristol Default 0

    115/365

    50 ms that is known to work best for Chesapeake CW LP using Modbus

    1

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 10 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    DIMENSIONED DRAWINGS

    3808 MVT with Manifold Adapters Shown

    2 11

    /16"

    2 1/

    8"

    1 5/

    8"

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 11 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    3808 MVT with L Flanged Mounting Bracket

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 12 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    3808 MVT with Neck Mounted Bracket

    2 1/

    4"

    3 5/

    8"

    1 7/

    8"

    2 7/

    8"

    13/1

    6"

    3 7/

    8"

    5 11

    /16"

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 13 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Simplified Diagram of 3808 MVT with 4 20 mA Signal

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 14 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    Simplified Diagram of 3808 MVT with RS 232 and RS 485 Interface

    COMPENSATIONELECTRONICS

    ELECTRONICS HOUSING

    SENSOR MODULEASSY.

    FLANGE(HI Side)

    LO PORTOVERPRESSUREMECHANISM And

    DIAPHRAGM

    FLANGE(LO Side)

    ISOLATIONDIAPHRAGM

    ISOLATIONDIAPHRAGM

    HI PORT

    HIGH SIDE FLUID SYSTEM

    LOW SIDE FLUID SYSTEM

    CPU BOARD

    5 to 42VdcPowerSupply

    RS-232Interface

    RS-485Interface

    RTD

    +

    SPIBUS

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 15 Bristol Multivariable Transmitter

    Remote Automation SolutionsWebsite: www.EmersonProcess.com/Remote

    3808 MVT Terminal Block Assignments

    3808 MVT Wire Routing

  • Product Data Document225DS-25h / D301300X012April 2011 - Page 16 Bristol Multivariable Transmitter

    Emerson Process ManagementRemote Automation Solutions

    Watertown, CT 06795 USA T 1 (860) 945-2200Mississauga,ON06795Canada T1(905)362-0880WorcesterWR38YBUK T44(1)905-856950

    Website: www.EmersonProcess.com/Remote

    2007-2011 Remote Automation Solutions, division of Emerson Process Management. All rights reserved.

    Bristol,Inc.,BristolCanada,BBISAdeCVandEmersonProcessManagementLtd,RemoteAutomationSolutionsdivision(UK),arewhollyownedsubsidiariesofEmersonElectricCo.doingbusinessasRemoteAutomationSolutions(RAS),adivisionofEmersonProcessManagement.FloBoss,ROCLINK,Bristol,BristolBabcock,ControlWave,TeleFlowandHelicoidare trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners.

    The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as war-ranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to modify or improve the designs or specificationsofsuchproductsatanytimewithoutnotice.AllsalesaregovernedbyRAStermsandconditionswhichareavailableuponrequest.RASdoesnotassumeresponsibilityforthe selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user.