Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1)...

16
Manifold Absolute Pressure MAP1 Revision#1.3, 5/11/2014 For firmware version 2.3 Flybox ®

Transcript of Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1)...

Page 1: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

Manifold Absolute PressureMAP1

Revision#1.3, 5/11/2014For firmware version 2.3

Flybox®

Page 2: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

Page intentionally left blank

Page 3: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MECHANICAL INSTALLATION

SECTIONS

DIMENSIONS

ELECTRICAL INSTALLATION

USE OF THE INSTRUMENT

TECHNICAL SPECIFICATIONS

Page 4: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

Page intentionally left blank

Page 5: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

Rev. 1.3

® Introduzione

Thank you for purchasing a Flybox® product. We hopeit fully satisfy you and makes your flights pleasant andsecure.Developing MAP1, our intent was to create a compactand lightweight manifold pressure indicator, easy toinstall and quick to consult.

SYMBOLS USED IN THE MANUAL

NOTE: Used to highlight important informations.

CAUTION: Used to warn the user and indicate a potentiallyhazardous situation or improper use of the product.

WARNING: Used to indicate a dangerous situation that cancause personal injury or death if the instruction isdisregarded.

Page 6: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

FLYBOX

MAP1 - User’s manualRev. 1.3

®

NOTE: Keep this manual in the aircraft.This document must accompany the instrument in the eventof change of ownership.

NOTE: This device is intended for installation onto non typecertified aircraft only, because it has no aviation certifications.Refer to your local aviation authorities to check if this devicemay be installed in your aircraft.

CAUTION: Read entirely this manual before installing theinstrument in your aircraft, and follow the installation andoperating instructions described here.

CAUTION: Using this instrument over the maximumallowable ranges can cause malfunction or wrong indications.

CAUTION: Microel s.r.l. reserves the right to change orimprove its products. Information in this document is subjectto changes without notice.

Page 7: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

Rev. 1.3

® Indice

2.1 9Dimensions SECTION 2

113.1 Electrical installation SECTION 3

SECTION 44.1 13Use of the instrument

5.1 14Technical specifications SECTION 5

81.1 SECTION 1

Mechanical installationConnect the manifold pressure line 8

Page 8: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

FLYBOX

MAP1 - User’s manual8Rev. 1.3

®Mechanical installation

SECTION 11.1 MECHANICAL INSTALLATION

The MAP1 fits in a standard 2 1/4” panel cutouts(57 mm).

1)

it's recommended to choose a position that permitsoptimal display visibility.

2)

Connect the pipe fitting on the back of the instrument tothe manifold pressure lines; the furnished pipe fitting issuitable for pipe with internal diameter of 5 mm.

WARNING: Take care to properly execute thisconnection because an eventual leakage cancause fuel vapour to enter in the cockpit.

- It's recommended to insert a restrictor valve to the pipeso that only little quantity of fuel vapour can exit in caseof leakage.

- With the MAP1 connected the pressure line mustnever exceed the pressure of 250kPa/74 InHg to avoiddamage to the instrument.

CONNECT THE MANIFOLD PRESSURE LINE:

Page 9: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

9Rev. 1.3

® Dimensions

SECTION 22.1 DIMENSIONS

Front view

Dimensions in millimeters

Page 10: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

FLYBOX

MAP1 - User’s manual10Rev. 1.3

®Dimensions

Side view

Dimensions in millimeters

Page 11: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

11Rev. 1.3

® Electrical installation

SECTION 33.1 ELECTRICAL CONNECTIONS

On the backpanel of the MAP1 there's a four-poleconnector, the connections are:

Page 12: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

FLYBOX

MAP1 - User’s manual12Rev. 1.3

®Electrical installation

+12 BATT: power lead, can be connected to an auxiliarybackup battery if present.

+12 V: power lead, connects to 12Volt main line.

GND: Ground lead.

NOTE: Insert a circuit breaker or fuse to the power lead.(+12V).

CAUTION: Voltage peaks on the supply line thatexceeds the operating limits can damage the device.

Connections details:

Page 13: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

13Rev. 1.3

® Use of the instrument

4.1 USE OF THE INSTRUMENT

SECTION 4

MAP1 measure and display in a large LCD the absolutemanifold pressure.

The measurement is executed by a solid-state sensorthat assures a high accuracy and a resolution of 0.1In.Hg.

The pressure is displayed in inches of mercury; thedisplay update rate is 3 time per second, whichguarantee a fast response time to pressure change.

Page 14: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

FLYBOX

MAP1 - User’s manual14Rev. 1.3

®Technical specifications

- Standard mounting 2 1/4” (57mm).

- Anodized aluminium case.

- Dimensions: 60 x 60 x 40.5 mm.

- Weight: 115 g.

- Supply voltage: 10~30 V=.

- Supply current: 20 mA.

- Range: 10~60 In.Hg.

- Resolution: 0.1 In.Hg.

- Accuracy: 1.5 %.

- Operating temperature range: -20~+70°C.

- Humidity: 10% ~ 90% without condensation.

5.1 TECHNICAL SPECIFICATIONS

SECTION 5

Page 15: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MAP1 - User’s manual

FLYBOX

15Rev. 1.3

®

WARRANTY:

This product is warranted to be free from defects for aperiod of 12 months from the user invoice date.

The warranty only covers manufacturer defects andshall not apply to a product that has been improperlyinstalled, misused or incorrect maintenance, repaired oraltered by non-qualified persons.

WARNING: All photos, data, drawings, instruments layouts, technical solutions anddata representation you find in this document or watching at FLYBOX® instrumentsworking and/or you can access by means of any other media, including web sites,are sole property of MICROEL s.r.l., cannot be copied or imitate without a writtenpermission of MICROEL s.r.l. itself and are protected by law, even by means ofextended international copyright and/or specific patents deposited. Any infringementof this statement and of MICROEL s.r.l. intellectual property will be prosecuted.

©2014 Microel s.r.l. – all rights reserved.

Date Version Description07/2007 1.2 First release10/2014 1.3 Layout update

Page 16: Manifold Absolute Pressure MAP1 · The MAP1 fits in a standard 2 1/4” panel cutouts (57 mm). 1) it's recommended to choose a position that permits optimal display visibility. 2)

MICROEL s.r.l.Via Mortara 192-194

27038 Robbio (PV) - ITALYTel +39-0384-670602 - Fax +39-0384-671830

www.flyboxavionics.it