ENGINEERING ARCHITECTUREwww.for-arch.com
EDIFICIO ALTOTERZIARIO
620 € / mq SLP
PALAZZO REGIONE FUKSAS
23 %
> 50.000 mq SLP
CLASSE AITACA
EDIFICIO TERZIARIO
242 € / mq SLP
EDIFICIO OROMILANO
FIERA
16 %
< 50.000 mq SLP
CLASSE A ALTA
EDIFICIO BASSOTERZIARIO
340 € / mq SLP
LAVAZZA HEADQUARTERS
TORINO
21 %
< 50.000 mq SLP
CLASSE ALEED
CONDOMINIORESIDENZA
420 € / mq SLP
BRESCIAEX COMPARTO
MILANO
32 %
< 5.000 mq SLP
CLASSE A
CASA UNIFAMILIARE
240 € / mq SLP
CASA FIGLIA SIGNORAPAUTASSO
24 %
< 200 mq SLP
CLASSE A
COSTO DELL'INVOLUCROIncidenza percentuale del costo sul totale per la costruzione (escluse coperure e solai contro terra)
* *
ENGINEERING ARCHITECTUREwww.for-arch.com
Canali impiantistici, analoghi ai canali proteici della cellula, di
collegamento tra ambiente esterno ed ambiente interno
London Imax (Fonte: fotografia dell’autore)
ANALOGIA (OVVIA) CON LA MEMBRANA CELLULAREPiù o meno parliamo della stessa cosa, più o meno le regole sono quelle
ENGINEERING ARCHITECTUREwww.for-arch.com
PELLE DECORATA E ISPIRAZIONEDa Paco Rabanne a Future System: la dimensione creativa e simbolica
ENGINEERING ARCHITECTUREwww.for-arch.com
LA DIMENSIONE PRESTAZIONALE: PER ORA TUTTO BENEMa questo è solo un aspetto della sostenibilità
ENGINEERING ARCHITECTUREwww.for-arch.com
SE ESALTSSIMO LE PRESTAZIONI ?Senza dimenticare il valore estetico
ENGINEERING ARCHITECTUREwww.for-arch.com
E SE INVECE TRASCURASSIMOIL VALORE ESTETICO ?Ecco una vera "integrazione" dei pannelli fotovoltaici nella casa spaziale
ENGINEERING ARCHITECTUREwww.for-arch.com
PITTURA DECORAZIONE PELLE PROTEZIONEAd un certo punto, qualcuno ci racconta che c'è un supporto strutturale ed un rivestimento 1860
ENGINEERING ARCHITECTUREwww.for-arch.com
DYNAMIC SOLAR SHADING & GLARE CONTROLIl Velarium dell'Amphitheatrum nei secoli passati
ENGINEERING ARCHITECTUREwww.for-arch.com
LUOGO DI TRANSIZIONECosa diverrebbe l'interno se non vi fosse un esterno ?
ENGINEERING ARCHITECTUREwww.for-arch.com
SILENT EX PLOSIONSNorvegian artist Espen Dietrichson levitates architecture
Non possiamo più pensarlo "staccato" e "vuoto"
ENGINEERING ARCHITECTUREwww.for-arch.com
STRUMENTI PER COMPRENDERE L'ESTERNO E L'INTERNOQuali competenze? Quante risorse?
ENGINEERING ARCHITECTUREwww.for-arch.com
STRUMENTI PER PRE-VALUTARENon abbiamo più scuse (e purtroppo non siamo Mies)
ENGINEERING ARCHITECTUREwww.for-arch.com
STRUMENTI PER CONVINCEREComunicazione e semplificazione del progetto
ENGINEERING ARCHITECTUREwww.for-arch.com
STRUMENTI PER SEMPLIFICARE COORDINAREbim bum bam? Hai 13.000 € da investire ?
ENGINEERING ARCHITECTUREwww.for-arch.com
PROGETTARE OGGI E' PIU FACILE DI IERIAlemno si è quasi sicuri di quello che si costruirà
ENGINEERING ARCHITECTUREwww.for-arch.com
PROGETTARE I DUE LATILa vivibilità degli spazi interni, la percezione del colore, la permeabilità ottica
ENGINEERING ARCHITECTUREwww.for-arch.com
1. The looming requirement for facade retrofit should be regarded as a fundamental infrastructure problem; energy efficiency and carbon reduction goals cannot be achieved without addressing this problem. 2. Meeting the demand will be costly and complex, with a high potential for the process being wasteful. 3. There is urgent need for defining appropriate retrofit strategies, evaluation criteria for their application, and the definition of means and methods for the implementation of the various strategies, possibly taking the form of best-practice guidelines for the various stakeholders. 4. Design practices for new facades that anticipate and accommodate the eventual need for retrofit could facilitate future retrofit requirements. Facade systems should be designed to facilitate the retrofitting of new materials and technology as developments occur. 5. Sustainable facade retrofit practices must be developed; a focus on material reuse is imperative to avoid filling landfills with discarded facade materials, particularly glass. 6. New architectural glass recycling (not down-cycling) technologies are needed. 7. Advanced facade solutions using raw float glass should be pursued because of the uncompromised material life and the potential for easy recycling. Double-skin strategies may accommodate this in certain applications. 8. Costing models that factor in the environmental cost of damaging construction practices and the true cost of energy are urgently needed to correct inaccurate perceptions of long payback periods for energy efficient technology.
FACADE RETROFITLine guides for beginners
ENGINEERING ARCHITECTUREwww.for-arch.com
VETROCAMERA ESTERNO
10 10 .4 + 16 + 10_ Stratificato Extrachiaro temprato (serigrafia in faccia lastra sud)_ Extrachiaro temprato StopRay Vision 60T_ 16 intercapedine aria_ 10 Monolitico extrachiaro temprato
CAMBIO GENERAZIONALE, CERTO, MA ANCHE COMPETENZAIl dialogo seve anche qui
ENGINEERING ARCHITECTUREwww.for-arch.com
"This section addresses the mitigation of explosion effects on the exterior envelope of a new building designed to meet federal anti-terrorist design requirements." ..........
SAFETY & SECURITYCi dobbiamo difendere dagli aerei e dai terroristi (stranieri)
ENGINEERING ARCHITECTUREwww.for-arch.com
NUOVI MATERIALI, RICERCA, DOMANI E' UN GIORNO NUOVOMa come possiamo essere aggiornati?
NESOCELL
ENGINEERING ARCHITECTUREwww.for-arch.com
Building Enclosure Commissioning (BECx) is a quality-oriented process to enhance the delivery of a new building or the retro-fit of an existing building in accordance with the Owner’s Project Requirements (OPR). The process includes tasks to achieve, verify, and document that the enclosure design and construction meets the expectations of the Owner and the performance criteria identified in the Construction Documents (CDs). The BECx process is comprised of numerous tasks and is performed during the standard phases of a project: Pre-Design, Design, Construction, and Occupancy. The primary tasks include:• Establishing a well-defined OPR and BECx Plan• Verifying that the details and specifications meet the OPR through careful design reviews of the CDs performed by a party knowledgeable in the detailing, performance, and construction practices/installation of building enclosures• Developing a building enclosure specification for inclusion in Division 1 of the Project Manual, inclusive of project specific field testing• Reviewing construction phase submittals and developing project-specific checklists• Laboratory or field mock-up of building enclosure and testing to validate performance• Periodic or ”milestone” observing, documenting and reporting of work during construction for compliance with CDs• Testing of assemblies throughout construction to validate performance• Report for the building enclosure “close-out”• Facility personnel training related to building enclosure operation and maintenance
LESSON NUMBER 1The Enclosure Commissioning (BECX)
ENGINEERING ARCHITECTUREwww.for-arch.com
GREENPIXUn esempio di metodo: Zero Energy Media Wall Beijing
ENGINEERING ARCHITECTUREwww.for-arch.com
BUDGET & TEMPIMa si risparmia davvero? A che prezzo?
Edificio campione S7V 0 =,25 Zona D 1455 GG (Roma)Superficie Mq 100 netti
ENGINEERING ARCHITECTUREwww.for-arch.com
COMUNE DI MILANO
Riduzione degli oneri di urbanizzazione Commerciale
Zona climatica E
Gradi giorno (GG) 2404
Superficie riscaldata dell'involucro tipo [S] 1200
Volume lordo riscaldato tipo [V] 2400
Fattore di forma [S/V] 0,5000
Valore limite di fabbisogno annuo di energia 16,95
Classi energetiche EPh % sconto su
oneri di OOUU
classe A+ 0<Eph<3 kWh/m3a 2 30,00%
classe A 3≤Eph<6 kWh/m3a 3 30,00%
4 30,00%
5 30,00%
classe B 6≤Eph<11 kWh/m3a 6 30,00%
9 30,00%
10 27,15%
classe C 11≤Eph<27 kWh/m3a 11 22,94%
13 14,51%
16 5,94%
17 0,00%
COMUNE DI MILANO
Riduzione degli oneri di urbanizzazione Commerciale
Zona climatica E
Gradi giorno (GG) 2404
Superficie riscaldata dell'involucro tipo [S] 1200
Volume lordo riscaldato tipo [V] 2400
Fattore di forma [S/V] 0,5000
Valore limite di fabbisogno annuo di energia 16,95
Classi energetiche EPh % sconto su
oneri di OOUU
classe A+ 0<Eph<3 kWh/m3a 2 30,00%
classe A 3≤Eph<6 kWh/m3a 3 30,00%
4 30,00%
5 30,00%
classe B 6≤Eph<11 kWh/m3a 6 30,00%
9 30,00%
10 27,15%
classe C 11≤Eph<27 kWh/m3a 11 22,94%
13 14,51%
16 5,94%
17 0,00%
LE ANALISI DI OPPORTUNITA'Costi VS Risparmi
ENGINEERING ARCHITECTUREwww.for-arch.com
1- Vetrata per residenziale standard
PERFORMANCE
Ug = 1,4 W/(mq.k)
Acustic = 35 Db
Solar Factor = 60
Selettività =1,3
VOCE €/mq
VETRO ESTERNO 4
VETRO INTERNO 14
TAGLIO E MOLATURA 10
SIGILLATURA IN VETRATA 26
CANALINO 2
GAS – aria 100% 0
SFRIDO E altri costi 8
COSTO TOTALE 64
STRUTTURA
Vetro esterno 4mm
Camera 16mm Aria
Vetro interno Low-E di sicurezza
ENGINEERING ARCHITECTUREwww.for-arch.com
2- Vetrata per residenziale selettiva acustica
PERFORMANCE
Ug = 1,0 W/(mq.k)
Acustic = 50 Db
Solar Factor = 50
Selettività =1,6
VOCE €/mq
VETRO ESTERNO 18
VETRO INTERNO 8
TAGLIO E MOLATURA 10
SIGILLATURA IN VETRATA 26
CANALINO 2
GAS – argon 90% 3
SFRIDO E altri costi 10
COSTO TOTALE 77
STRUTTURA
Vetro esterno selettivo 66mm
Camera 20 mm Argon
Vetro interno 44 acustico
ENGINEERING ARCHITECTUREwww.for-arch.com
3- Vetrata ad alto protezione solare
PERFORMANCE
Ug = 1,0 W/(mq.k)
Acustic = 45 Db
Solar Factor = 20
Selettività =1,6
VOCE €/mq
VETRO ESTERNO 25
VETRO INTERNO 8
TAGLIO E MOLATURA 10
SIGILLATURA IN VETRATA 26
CANALINO 2
GAS – argon 90% 3
SFRIDO E altri costi 10
Tempra 8 mm 16
COSTO TOTALE 100
STRUTTURA
Vetro esterno 8mm selettivo temp
Camera 16mm Aria
Vetro interno di sicurezza
ENGINEERING ARCHITECTUREwww.for-arch.com
4- Vetrata super-selettiva (3Ag)
PERFORMANCE
Ug = 1,0 W/(mq.k)
Acustic = 45 Db
Solar Factor = 25
Selettività =2,1
VOCE €/mq
VETRO ESTERNO 40
VETRO INTERNO 8
TAGLIO E MOLATURA 10
SIGILLATURA IN VETRATA 26
CANALINO 2
GAS – argon 90% 3
SFRIDO E altri costi 15
COSTO TOTALE 104
STRUTTURA
Vetro esterno Ultra 44mm
Camera 16mm Argon 90%
Vetro interno di sicurezza
ENGINEERING ARCHITECTUREwww.for-arch.com
5- Vetrata Tripla
PERFORMANCE
Ug = 0,5 W/(mq.k)
Acustic = 42 Db
Solar Factor = 40
Selettività =1,7
VOCE €/mq
VETRO ESTERNO 16
VETRO INTERNO 16
TAGLIO E MOLATURA 15
SIGILL. IN doppia VETRATA 35
CANALINI 4
GAS – argon 5
SFRIDO E altri costi 15
Vetro centrale Temprato 10
COSTO TOTALE 116
STRUTTURA
Vetro esterno selettivo 55mm
Camera 16mm Argon90%
Vetro intermedio temprato 6mm
Camera 16mm Argon90%
Vetro interno Low-E di sicurezza
ENGINEERING ARCHITECTUREwww.for-arch.com
6- Vetrata con trasformazioni speciali
PERFORMANCE
Ug = 1,0 W/(mq.k)
Acustic = 42 Db
Solar Factor = 20
Selettività =1,8
VOCE €/mq
VETRO ESTERNO 30
VETRO INTERNO 10
TAGLIO E MOLATURA 10
SIGILLATURA IN VETRATA 26
CANALINO 2
GAS – argon 90% 3
SFRIDO E altri costi 8
Tempra 20
Serigrafia 15
COSTO TOTALE 124
STRUTTURA
Vetro esterno 10mm selettivo
temprato
Camera 16mm Aria
Vetro interno di sicurezza