Manaen Srigiri James Abhilash DEMAND RESPONSE ___________________________ OUR RESPONSE TO CRITICAL...
-
Upload
walter-thompson -
Category
Documents
-
view
226 -
download
1
Transcript of Manaen Srigiri James Abhilash DEMAND RESPONSE ___________________________ OUR RESPONSE TO CRITICAL...
Manaen SrigiriJames Abhilash
DEMAND RESPONSE___________________________
OUR RESPONSE TO CRITICAL CHALLENGES
• The Company develops, and manufactures smart grid solutions for electricity, water and gas utilities.
• The Company’s Advanced Meter Infrastructure (AMI) portfolio includes a data management system housed at utilities data centres, smart meters and concentrators, intelligent consumer monitoring solutions, as well as load limitation devices.
• The Company also provides solutions for industrial users including sub-metering applications.
• The Company is certified worldwide by KEMA. Applied for BIS too.
• The Company is supported by a strong design group based in Israel as well as manufacturing facility in India & subsidiaries in South Africa, and Hong Kong.
COMPANYOverview
SYSTEM ELEMENTSOverview
• Under Frequency Load Management
• Demand Response Using Smart Meters
• Distribution Demand Automation
Key Elements
ENERGY SUPPLY PROTECTIONOverview
Central Office Software
UTILITY WAN
PLC/GPRS
Feeder/Distribution Transformer
Smart Meters
Concentrator
Din Rail APM
Smart Meter
PLC
PLC
GPRS/LAN
Built-in GPRS Communication
Unrestricted DemandNew Max. Demand
1000 Amps
100 Amp50 Amp
150 Amp75 Amp
150 Amp75 Amp
180 Amp90 Amp
230 Amp115 Amp
140 Amp70 Amp
Concentrator + CT
SYSTEM ELEMENTSOverview
95% of capacity
Overview
•Special circuitry installed within three phase/HT/MV meters.•Installed on feeders, and distribution transformers. •Continuously monitors frequencies and reacts with 70ms to frequency variations nearing full capacity by activating a digital output to connect or reconnect certain lines exceeding configurable value. •Automatic reconnection after a configurable period if power consumption is within limits defined. •Customizable limits on individual or groups of consumers. •Remote activation via communications of critical condition limits by automation or manual operation.
SYSTEM ELEMENTSUnder Frequency Meters
• Installed in industrial and commercial customers where significant non-critical power usage justifies the cost.
• Relay to isolate and disconnect non-critical machinery remotely. The machinery/appliances themselves do not need any smart nodes built–in.
• Optional din-rail devices which communicate with the Meter to disconnect specific lines.
SYSTEM ELEMENTSLoad Control Element
• Imax - predefined setting protects the circuit breakers belonging to the utility. i.e. automatic disconnection above 100 amps.
• Icritical – During critical status when transformer is supplying near maximum capacity, select customers are limited at varying power levels. i.e. automatic disconnection above 60 amps.
Certain category groups of customers may be defined as exempt from load limitations (frail/elderly and emergency services).
SYSTEM ELEMENTSPowerCom Smart Meters
LOAD MANAGEMENTBenefits
Protect Assets
Avoid massive energy pulses by staggering load shedding frequencies.
Prevent transformer overload. Protect dist. transformers.
Customer Satisfaction
Modifiable frequency disconnection levels - same consumers not always the first affected.
Personalized pricing.
Real-Time
AutomationGrouping of Customers.
User friendly software.
Peak shaving & load shifting. Reduce infrastructure invest.
Two-way reliable and low-cost communications.
Modify configuration values remotely.
JnJ Powercom Systems LtdJnJ House,
Plot.41, Phase-III, Cherlapally IA,Hyderabad-500051. IndiaMobile: +91-9849002180
Email: [email protected]
Thank you