Make the Right Connection - Henry Schein

20
Make the Right Connection Electrosurgical & Smoke Evacuation Products

Transcript of Make the Right Connection - Henry Schein

Page 1: Make the Right Connection - Henry Schein

M a k e t h e R i g h t C o n n e c t i o n

Electrosurgical & Smoke Evacuation Products

Page 2: Make the Right Connection - Henry Schein

2

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

ELECTROSURGICAL PRODUCTSDeRoyal proudly presents the highest quality and broadest selection of cautery pencils, electrodes, grounding pads, and smoke evacuation products for the surgical market. All DeRoyal ElectrosurgicalProducts are indemnified for use with all ESU generators that are available.

ELECTROSURGICAL PENCILS PAGE

Hand-Activated Electrosurgical Pencils 3Breazeale Fine Touch™ Electrosurgical Pencil 4Suction Coagulators 5

ELECTRODES

Single-Use Electrodes 6 PTFE Coated Laprascopic Electrodes 7

SPECIALTY ELECTRODES

Micro Needles 8LLETZ Electrodes 8Bayonet Electrodes 9

ARTHROSCOPIC ELECTRODES

Arthroscopic Electrodes 9

DISPERSIVE ELECTRODES

Hydrogel & Adhesive Gel Dispersive Electrodes 10

ELECTROSURGICAL ESSENTIALS

Electrode Tip Cleaner 11Disposable Bipolar Cord 11

SMOKE EVACUATION PAGE SYSTEMS & PRODUCTS

Crystal Vision Smoke Evacuation Machine 12-14ExtendEVAC™ Smoke Evacuation Pencils and Attachments 15Smoke Evacuation Machine Filters and Adapters 16-17Universal Smoke Evacuation Attachments and Accessories 18Smoke Evacuation Tubing & Accessoriesfor Laparoscopic or Laser Procedures 19

ILLEGAL RESTRAINTS OF TRADE 20

DEROYAL CUSTOMERINDEMNIFICATION POLICY 20

DISCLAIMER 20

TABLE OF CONTENTS

All DeRoyal smoke evacuation products are available bulk non-sterile by deleting zeros after the dash and adding an NS to the end of any product number. DeRoyal products may be covered by one or more of the following U.S. or Foreign patents 5,693,044, 5,431,650, 5,318,516, 5,199,944, 5,108,389, EP 0538 6 41, 592 08 677.1-08, 6,099,525, 6,142,995, 6,458,125B1, and D501, 047S. Other U.S. and/or foreign patents may be pending.

Page 3: Make the Right Connection - Henry Schein

3

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Hand-Activated Electrosurgical Pencils • Reliability at your fingertips• Three-prong plug fits most electrosurgical generators• Flexible 10’ cord for easy set up and drapeability• Universal chuck accommodates C\cx” electrode• Yellow and blue color-coded switch with audible and tactile feedback to confirm

activation and identify cut/coag controls• Fluid-proof textured barrel prevents slipping or shock• New versions available with PTFE coated electrodes that reduce tissue adhesion• Single use only• Latex free

Product No. Description

OEM OEM Sterile Sterile Non-Sterile Non-Sterile Uncoated PTFE Coated Uncoated PTFE Coated

88-000031 88-000041 88-000003 88-000006 Rocker Switch Pencil88-000032 88-000042 88-000004 88-000007 Button Switch Pencil88-000001 88-000021 _________ _________ Rocker Switch Pencil w/Holster88-000002 88-000022 _________ _________ Button Switch Pencil w/Holster88-001501 88-001521 88-101501 88-101521 Rocker Switch Pencil w/15’ Cord, Holster88-001502 88-001522 88-101502 88-101522 Button Switch Pencil w/15’ Cord, Holster88-000051 _________ _________ _________ Rocker Switch Pencil w/Holster, Tip Cleaner88-000052 _________ _________ _________ Button Switch Pencil w/Holster, Tip Cleaner88-000008 _________ 88-000005 _________ Holster _________ 88-000223 _________ _________ Button Switch Pencil w/1” ENT Blade, Holster88-000222 _________ _________ _________ Button Switch Pencil w/1” Needle, HolsterAll packaged Sterile, 1/Pk, 25 Pks/Bx, 2 Bxs/Cs.All Non-Sterile pencils are 100/Cs, holster sold separately.Geo-Med catalog numbers for PTFE Pencil now available by adding a “G” to end of product number (i.e. 88-000021G).

ELECTROSURGICAL PENCILS

Page 4: Make the Right Connection - Henry Schein

4

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Breazeale Fine Touch™ Electrosurgical Pencil• Revolutionary design moves rocker switch placement closer to the electrode for

much finer control when cutting or cauterizing tissue• Designed by a Plastic Surgeon specifically for plastic surgery for precise results• Pencil is weighted forward for greater control and accuracy• The ergonomic design allows for even greater tip control and comfort• Available pre-loaded with the most common electrodes used by plastic surgeons• Universal connection cord fits all generators• Single use only• Latex free

ELECTROSURGICAL PENCILS

Side view of ergonomic forward-weighted design of the Breazeale pencil (top) compared with a regular electrosurgical pencil (below).

A top view showing the forward switch placement of the Breazeale pencil (top) for precise control compared with the set-back switch placement of a regular pencil (below).

Product No. Description Sterile Sterile Sterile Uncoated PTFE Coated Uncoated*

88-FT31 88-FT41 ________ Rocker Switch Pencil88-FT01 88-FT21 88-FT0110 Rocker Switch Pencil w/Holster88-FT51 ________ ________ Rocker Switch Pencil w/Holster, Tip Cleaner88-FT12 88-FT12C ________ Rocker Switch Pencil w/1” Needle, Holster88-FT103 ________ 88-FT10310 Rocker Switch Pencil w/Micro Needle, Holster88-FTM13 88-FTM13C ________ Rocker Switch Pencil w/1” ENT Blade, Holster88-FTM12 88-FTM12C ________ Rocker Switch Pencil w/1” ENT Needle, HolsterAll packaged 1/Pk, 25 Pks/Bx, 2 Bxs/Cs unless otherwise noted.For Non-Sterile number, add NS to sterile part number, 100/Cs. Holster sold separately.* Packaged 1/Pk, 10 Pks/Bx, 1 Bx/Cs.

Page 5: Make the Right Connection - Henry Schein

5

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Suction Coagulators• Two functions, one instrument• Increased efficiency during procedures requiring controlled fluid evacuation • Facilitates precise electrosurgical coagulation• Suction and coagulation can be performed independently or simultaneously• Foot switching or hand switching “coag” activation to accommodate preferences• Vented handle for suction control • Handle ergonomically designed to provide a sure grip when wet and improve tactile sensitivity.• Flexible configuration allows clinician to match instruments to specific surgical need • Single use only• Latex free

Product No. Description

KW-30-5200 10FR Suction Coagulator w/Hand Switch Activation88-2505-10FR 10FR Suction Coagulator w/Foot Switch ActivationAll Packaged Sterile, 1/Pk, 10 Pks/Cs.

ELECTROSURGICAL PENCILS

Page 6: Make the Right Connection - Henry Schein

6

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Single-Use Electrodes• Convenience that is cost effective• PTFE coated electrodes reduce tissue adhesion• Product offering includes most widely used blades, needles, and ball electrodes available for specific applications• Available in regular and extended lengths to access deep cavities• ENT/Modified versions available in coated or stainless steel• Single use only• Latex free

Product No. Description

Uncoated PTFE Coated Uncoated ENT/Modified PTFE Coated ENT/Modifed

(E) 88-000013 (F) 88-000M13 (M) 88-000013C 88-000M13C 1” Blade Electrode(G) 88-000012 (H) 88-000M12 (L) 88-000012C (K) 88-000M12C 1” Needle Electrode(A) 88-000011 (B) 88-000M11 (P) 88-000011C 88-000M11C 6” Blade Electrode(C) 88-000010 (D) 88-000M10 (O) 88-000010C 88-000M10C 6” Needle Electrode _________ _________ (N) 88-000015C ___________ 4” Blade Electrode(I) 88-000014 _________ (J) 88-000014C ___________ 3 /16” Ball Electrode 88-000713 _________ 88-000713C ___________ 1” Blade for ExtendEVAC™ Pencil 88-000712 _________ 88-000712C ___________ 1” Needle for ExtendEVAC™ PencilAll Packaged Sterile, 1/Pk, 25 Pks/Cs.OEM Availability: For Non-Sterile number, replace the initial “0” after dash with “1”, i.e. 88-100013C, 100/Cs.Geo-Med PTFE coated electrodes now available by adding a “G” to end of product number (i.e. 88-000013CG).

ELECTRODES

A B C D

E F G H I J K L MN

O P

Page 7: Make the Right Connection - Henry Schein

7

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

ELECTRODES

PTFE Coated Laparoscopic Electrodes• New PTFE coated electrodes for reduced tissue adhesion• Product offering that includes most widely used tips and lengths for specific

applications• Helps provide excellent dissection and coagulation• Fully insulated shaft prevents stray current and unwanted burns• Disposable, convenient, and cost-effective• Single use only• Latex free

Product No. Description Stem Qty.

88-0017 Standard Blade, 33 cm (14.2”) Pencil 6/Bx88-0018 Round Spatula, 33 cm (14.2”) Pencil 6/Bx88-0019 Curved Spatula, 33 cm (14.2”) Pencil 6/Bx88-0019S Curved Spatula, 33 cm (14.2”) Split 6/Bx88-0019L Curved Spatula, 45 cm (17.7”) Pencil 6/Bx88-0019LS Curved Spatula, 45 cm (17.7”) Split 6/Bx88-0020 L Hook, 33 cm (14.2”) Pencil 6/Bx88-0020S L Hook, 33 cm (14.2”) Split 6/Bx88-0020L L Hook, 45 cm (17.7”) Pencil 6/Bx88-0020LS L Hook, 45 cm (17.7”) Split 6/Bx88-0021 J Hook, 33 cm (14.2”) Pencil 6/Bx88-0021S J Hook, 33 cm (14.2”) Split 6/Bx88-0021L J Hook, 45 cm (17.7”) Pencil 6/Bx88-0021LS J Hook, 45 cm (17.7”) Split 6/Bx88-0022 Needle, 33 cm (14.2”) Pencil 6/Bx88-0022S Needle, 33 cm (14.2”) Split 6/Bx88-0024 Ball, 33 cm (14.2”) Pencil 6/Bx88-0100 L Wire, 33 cm (14.2”) Pencil 6/Bx88-0100S L Wire, 33 cm (14.2”) Split 6/Bx88-0100L L Wire, 45 cm (17.7”) Pencil 6/Bx88-0100LS L Wire, 45 cm (17.7”) Split 6/Bx88-0105 J Wire, 33 cm (14.2”) Pencil 6/Bx88-0105S J Wire, 33 cm (14.2”) Split 6/Bx

OEM Availability: Add “NS” to the end of the part number for Non-Sterile items, 100/Cs.

ELECTRODE TIP STYLES

STEMS

Round Spatula

Needle

L Hook

L Wire

Pencil Stem

Curved Spatula

J Hook

J Wire

Split Stem

Page 8: Make the Right Connection - Henry Schein

8

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

SPECIALTY ELECTRODES

DeRoyal’s line of premium electrodes offers cost effective and high quality for use during your specialty arthroscopic and plastics procedures.

Micro Needles• Precision in cutting and coagulation without the expense of a laser• Ultra-sharp tip allows use of extremely low wattage• Tungsten tip for heat resistance• Insulated within 3 mm of tip to allow deep tissue access without the risk of accidental burns• Single use only• Latex free

Product No. Description Quantity

88-103 3cm Micro Needle 10/Cs88-104A 4cm Micro Needle Electrode 10/Cs88-112A 2cm Micro Needle w/3 mm 45º Angle 10/Cs88-113A 3cm Micro Needle w/3 mm 45º Angle 10/Cs88-117 Micro Needle w/45º Angle 10/CsOEM Availability: Add “NS” to the end of the above product numbers for Non-Sterile items, 100/Cs.

• Wire loop tungsten electrodes• Greater precision and durability than stainless steel• Resists breakage at higher generator levels• Excellent stability against flexing or bending during surgical use• Quality loops that minimize thermal damage and present good histopathology specimens • Ideal for outpatient or office surgery• Available in a variety of loop sizes• Single use only• Latex free

LLETZ Electrodes

Product No. Description Quantity88-1559 10 mm x 10 mm LLETZ Loop Electrode 10/Cs88-1560 15 mm x 12 mm LLETZ Loop Electrode 10/Cs88-1561 20 mm x 12 mm LLETZ Loop Electrode 10/Cs88-1562 20 mm x 15 mm LLETZ Loop Electrode 10/Cs88-1563 3 mm Diameter LLETZ Ball Electrode 10/Cs88-1564 5 mm Diameter LLETZ Ball Electrode 10/Cs88-1565 5 mm x 5 mm LLETZ Square Loop Electrode 10/Cs88-1566 10 mm x 4 mm LLETZ Square Loop Electrode 10/Cs88-1567 10 mm x 8 mm LLETZ Square Loop Electrode 10/CsAdd NS to the end of the above products for Non-Sterile items, 100/Cs.

Page 9: Make the Right Connection - Henry Schein

9

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Bayonet Electrodes• Tungsten steel electrodes • Does not bend or break under extreme power levels• Insulated shaft protects against accidental tissue burns• Ideal for neurological and orthopedic spinal procedures• Single use only• Latex free

Product No. Description Quantity88-11020 2 mm Loop Bayonet Electrode 10/Cs88-11040 4 mm Loop Bayonet Electrode 10/Cs88-11060 6 mm Loop Bayonet Electrode 10/Cs88-11080 8 mm Loop Bayonet Electrode 10/Cs88-11200 2.4 mm Ball Bayonet Electrode 10/Cs88-11300 5 mm Needle Bayonet Electrode 10/CsAdd NS to the end of the above products for Non-Sterile items, 100/Cs.

SPECIALTY ELECTRODES

Arthroscopic Electrodes• For use in arthroscopic procedures where irrigating solutions are used in conjunction with an

electrosurgical pencil• Insulation extending to the electrode tip for precise energy delivery• Transparent insulation improves surgeon’s tip visualization• Stabilizing electrode cap ensures a safe connection from electrode to pencil• Compatible with all pencils for ease of conversion• 6 Z\x” (16.51 cm) length• Single use only• Latex free

Product No. Description Quantity

88-1510 Insulated Arthroscopic Hook Electrode, 90 Degree Angle 10/Cs88-1511 Insulated Arthroscopic Hook Electrode, 45 Degree Angle 10/Cs88-1512 Insulated Arthroscopic Angled Blade Electrode, 90 Degree Angle 10/Cs88-1513 Arthroscopic Angled Blade Electrode, 90 Degree Angle 10/Cs88-2510 Rocker Pencil w/88-1510 Electrode 10/Cs88-2511 Rocker Pencil w/88-1511 Electrode 10/Cs88-2512 Rocker Pencil w/88-1512 Electrode 10/Cs88-2513 Rocker Pencil w/88-1513 Electrode 10/Cs88-2610 Push Button Pencil w/88-1510 Electrode 10/Cs88-2611 Push Button Pencil w/88-1511 Electrode 10/Cs88-2612 Push Button Pencil w/88-1512 Electrode 10/Cs88-2613 Push Button Pencil w/88-1513 Electrode 10/Cs

ARTHROSCOPIC ELECTRODES

Page 10: Make the Right Connection - Henry Schein

10

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Hydrogel and Adhesive Gel Dispersive Electrodes• Strong adhesion, yet gentle removal• Standard plugs work with most electrosurgical generators• Flexible 10’ cord for easy set up and drapeability• Impermeable foam backing and non-conductive adhesive border securely seal out fluids creating a moisture-safe barrier• Thin, flexible hydrogel, or adhesive gel pads conform to a variety of anatomical sites and allows easy removal without pulling hair or injury to skin• New FlexiPad™ has unique shape and advanced hydrogel to better conform and adhere to body contours• Single use only• Latex free

Product No. Description

FlexiPad™ Adhesive Gel Hydrogel______ 88-000201 88-000101 Adult Mono/Standard Pad88-104 88-000202 88-000102 Adult Dual Conductor Pad88-106 _________ 88-000103 Adult Dual Conductor Pad w/15’ Cord______ 88-000302 _________ Pediatric Dual Conductor PadAll packaged Non-Sterile, 1/Pk, 50 Pks/Bx, 1 Bx/Cs.

DISPERSIVE ELECTRODES

FlexiPad™

Page 11: Make the Right Connection - Henry Schein

11

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Electrode Tip Cleaner• A convenient debris removal system• Coated scratch pad eliminates disruptive scraping of electrodes or instruments for quick and easy

cleaning of instrument tips• Raypaque™ element ensures x-ray detectability• Adhesive backing securely holds on draped surface• Single use only• Latex free Product No. Description Quantity

32-200 2” x 2” Tip Cleaner 1/Pk, 25 Pks/Bx, 4 Bxs/Cs30-200 2” x 2” Tip Cleaner 1/Pk, 240 Pks/CsOEM Availability: For Non-Sterile number, add NS, 1000/Cs.

Disposable Bipolar Cord• For use in conjunction with ophthalmic/neurosurgical microsurgical bipolar forceps• Single use only• Latex free

Product No. Description Quantity

88-001000 12’ Bipolar Cord, Sterile 1/Pk, 10 Pks/CsOEM Availability: For Non-Sterile number, replace the initial “0” with “1”after dash, 100/Cs.

ELECTROSURGICAL ESSENTIALS

Page 12: Make the Right Connection - Henry Schein

12

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Hands free smoke evacuation

• With Crystal Vision, you can choose to use our ExtendEVAC™ pencil with integral telescoping tip or a regular electrocautery pencil snapped into our convenient smoke evacuator sheath for complete elimination of smoke from the O.R. Both can be conveniently held in one hand by the surgeon, with the evacuator conveniently located for ease of use.

ULPA filtration and sensors

• Crystal Vision’s built-in sensors prevent smoke particles from infiltrating the operating room by alerting the operator when ULPA filter is full and stopping the machine automatically if not changed within a few minutes.

Easy-to-read console

• The front panel of Crystal Vision illuminates automatically when room lights are lowered, with red light indicators for “high flow” and green for “low flow.”

ESU Sensor

• The unit automatically activates when the pencil is activated and stops when the pencil is deactivated for efficient, quiet operation.

Meet OSHA Guidelines

• OSHA has stated that all surgical smoke produced by lasers should be properly filtered by a smoke evacuation system as close to the surgical site as possible.

Laser Footswitch Sensor

• The footswitch sensor will automatically activate smoke evacuation once the laser is active.

Additional Procedures

• Speculum tubing allows the evacuation of smoke for GYN and ENT removal of nodes, growths and genital warts. Our laser tubing has a male barb that fits perfectly over the smoke evacuation port on most speculums.

Occlusion Light

• The Crystal Vision Machine will alert you for any obstructions within the speculum port or tubing during the procedure.

Across-The-Board Safety

• Using our smoke evacuation system will ultimately remove the toxic smoke to reduce the chance of viral airborne transfer.

ADVANTAGES FOR OPEN PROCEDURES

ADVANTAGES FOR LASER PROCEDURES

SMOKE EVACUATION SYSTEMS & PRODUCTSCrystal Vision Smoke Evacuation Machine

Page 13: Make the Right Connection - Henry Schein

13

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Clinically superior

• Crystal Vision automatically removes CO2 gas from abdomen post-procedure reducing post-operative pain by reducing the CO2 trapped inside patient at the end of the procedure. Patient’s body will absorb less CO2, producing better patient outcomes by reducing recovery time and medication required post-operatively.

• The laparoscopic smoke evacuation tubing set conveniently attaches directly to secondary trocar stopcock and is virtually invisible to the physician so it does not change current laparoscopic technique..

Constant monitoring of pneumoperitoneal pressure• With Crystal Vision, the amount of internal pneumoperitoneal pressure is constantly assessed and

automatically reduced when needed to lower potentially dangerous pressure levels.

Increases patient comfort

• By eliminating the CO2 gas, Crystal Vision can eliminate patient discomfort usually associated with remaining gas pockets post-operatively

Low flow range

• Unique to Crystal Vision is its low flow range that is easily adjusted to match the “in-flow” rate of the insufflator, helping maintain pneumoperitoneal pressure and freeing the surgeon to concentrate on the procedure.

Automatic tissue protection response

• The Crystal Vision pump stops automatically if tissue is accidentally suctioned to minimize potential trauma.

Eliminates smoke back-flow into patient

• With Crystal Vision, clean CO2 gas maintains internal pressure inside the patient, so that smoke is not allowed to infiltrate the surgical site.

Manual activation capability

• Crystal Vision can be manually activated to remove intra-abdominal gases at the end of procedures, eliminating the need to apply hand pressure to the patient’s abdomen. Shut-off is automatic when complete.

“During surgical procedures using laser or electrosurgical unit, the thermal destruction of tissue creates a smoke byproduct. Research studies have confirmed that this smoke plume can contain toxic gases and vapors such as benzene, hydrogen cyanide, and formaldehyde, bioaerosols, dead and live cellular material (including blood fragments), and viruses. At high concentrations, the smoke causes ocular and upper respiratory tract irritation in health care personnel, and creates visual problems for the surgeon. The smoke has unpleasant odors and has been shown to have mutagenic potential.” -- Center for Disease Control and Prevention, U.S. Department of Health and Human Services National Institute for Occupational Safety and Health. NIOSH Hazard Controls, “Control of Smoke From Laser/Electric Surgical Procedures,” September, 1996.

ADVANTAGES FOR LAPAROSCOPIC PROCEDURES

SMOKE EVACUATION SYSTEMS & PRODUCTS

Page 14: Make the Right Connection - Henry Schein

14

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Crystal Vision Smoke Evacuation Machine• For use with open and laparoscopic procedures• Advanced smoke evacuation unit with the quality, stamina and affordability • The clear choice for maximized smoke elimination in the O.R.• Non-sterile

Product No. Uncoated Description Quantity

88-350D Model 350D Crystal Vision Smoke Evacuation Unit w/ESU Sensor for Open & Laparoscopic Procedures 1/Cs88-360 Model 360 Crystal Vision Smoke Evacuation Unit w/ESU Sensor for Open Procedures Only 1/Cs

SPECIFICATIONS - MODEL 360, 350-D

Size: 7.25” H x 14.0” W x 15.0” D

Weight: Less than 17 pounds

Power Requirements: 100–240 V.A.C., single phase, 50-60 Hz, 2.5 amp

Flow Rate: High Flow Range: used in both 350-D and 360 25–100 Liters/Minute ± 10%

Low Flow Rate: 350-D only – used in laparoscopic and endoscopic procedures 3.5–18 Liters/Minute ± 10%

Activation: ESU Sensor, laser footswitch sensor, and manual switch

“The AORN recommended practices for electrosurgery states, ‘Exposure to smoke plume generated during electrosurgery should be reduced.’ This plume contains chemical by-products, and research suggests that there is little difference between laser and electrosurgical plume. Any smoke plume or noxious fumes are irritating to the respiratory tract. The potential for bacterial and viral contamination from surgical smoke is undefined; however it is known that mutagenicity of the gaseous by-products do exist. A wall suction device with an in-line filter is sufficient in keeping the air clear of smoke, a single - or triple-filter smoke evacuation unit should be used according to the need demonstrated. Regardless of the type of evacuation system used, the capture device should be placed as close as possible to the source of plume generation.” -- AORN Journal, Vol. 68, No. 5. “Clinical Issues: Smoke Plume,” November, 1998.

SMOKE EVACUATION SYSTEMS & PRODUCTS

Page 15: Make the Right Connection - Henry Schein

15

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Product No. Product No. Uncoated Coated Description Quantity

88-000702 88-000722 ExtendEVAC™ Button Switch Pencil w/Telescoping Smoke Evacuator Tip,10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs88-015702 88-015722 ExtendEVAC™ w/15’ Cord, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs88-00M702 88-00M722 ExtendEVAC™ w/ENT Electrode Assembly, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs _________ 88-000725 ExtendEVAC™ PTFE Blade, 10’ Tubing C\,” Diameter, Holster 1/Pk, 10 Pks/Bx, 1 Bx/Cs88-103702 _________ ExtendEVAC™ w/MicroNeedle, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-00M3 88-00M3C Replacement Telescoping ENT Blade Electrode Assembly for ExtendEVAC 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000704 88-000724 ExtendEVAC™ w/1” Needle, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000713 88-000713C 1” Blade for ExtendEVAC Pencil 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000712 88-000712C 1” Needle for ExtendEVAC Pencil 1/Pk, 25 Pks/Bx, 1 Bx/Cs88-00M706 88-00M726 ExtendEVAC™ w/Removable ENT Electrode, 10’ Tubing, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs88-000726 88-000727 ExtendEVAC™ w/45º Blade, 10’ Tubing, Holster 1/Pk, 25 Pks/Bx, 1 Bx/CsAll smoke evacuation products are available bulk Non-Sterile by adding “NS” to the end of any product number.

SMOKE EVACUATION SYSTEMS & PRODUCTS

ExtendEVAC™ Smoke Evacuation Pencils and Attachments• Integral to pencil for use with wall suction or any smoke evacuation machine • Clear visible tip allows visualization of entire electrode tip• Revolutionary low profile ExtendEVAC™ pencil with integral telescoping smoke evacuation tip• Adjusts electrode from 1” to 6” without changing electrode, saving time and money • Telescoping smoke evacuation remains close to cautery site for optimum performance• Soft tubing with swivel for ease of use• ENT version available with clear narrow telescoping tip for tight spaces• Single use only• Latex free

Page 16: Make the Right Connection - Henry Schein

16

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Smoke Evacuation Machine Filters and Adapters• Everything needed for use with both Crystal Vision machines and a variety of other smoke evacuation units• High quality, dependable • Competitively priced• Non-sterile• Single use only• Latex free

FILTERS

Product No.

Uncoated Description Quantity

88-000694 ULPA Water Trap Filter with C\,” Tubing Adapter for Crystal Vision Smoke Evacuation Units 1/Pkg, 10 Pkgs/Cs88-000697 Charcoal Output Filter for Crystal Vision Smoke Evacuation Units 1/Cs88-000698 Replacement ESU Sensor w/Cable for Crystal Vision Smoke Evacuation Units 1/Cs88-000699 Laser Foot Pedal Sensor w/Cable 1/Cs88-000691 ULPA Filter w/2’ Tubing for Wall Suction Evacuation of Smoke 1/Pkg, 10 Pkgs/Cs88-000447 Footswitch 1/Cs

88-000697 88-00069888-000691 88-000694

SMOKE EVACUATION SYSTEMS & PRODUCTS

Page 17: Make the Right Connection - Henry Schein

17

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

88-000692

88-000690

88-000689

71-1165

88-000693

88-000696

ADAPTERS

Product No.

Uncoated Description Quantity

88-000692 Suction Canister Adapter 30Fr Z\v” to C\,” 10/Cs88-000693 Tubing Adaptor C\,” for Crystal Vision Smoke Evacuation ULPA Water Trap filter 10/Cs88-000689 High Flow Smoke Evacuation Filter for Crystal Vision units 10/Cs88-000690 Filter Adaptor C\,” to M\,” for Smoke Evacuation Units from Buffalo Filter, Stackhouse, Class, Sorenson Labs, Nordex Medical, Conmed, and Neptune from Stryker 10/Cs88-000696 Prefilter Adapter for ValleyLab OptiMumm™ & Air Force™ Smoke Evacuation units 10/Cs71-1165 In-Line T Connector* 10/Cs* To split suction line from regulator between roll stand and smoke evacuation.All smoke evacuation products are available bulk Non-Sterile by adding “NS” to the end of any product number.

SMOKE EVACUATION SYSTEMS & PRODUCTS

Page 18: Make the Right Connection - Henry Schein

18

www.deroyal.com 800.251.9864

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

Universal Smoke Evacuation Attachments and Accessories• Universal snap-on sheath attachments convert standard pencil into a smoke evacuation pencil• Fits all electrosurgical pencils available on market• Also available pre-attached to DeRoyal Cautery Pencil• Single use only• Latex free

Product No. Product No. Uncoated Coated Description Quantity

88-000600 _________ Universal Smoke Evacuation Attachment w/10’ Tubing C\,” Diameter 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000601 88-000621 Rocker Switch Pencil w/Smoke Evacuation Attachment, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000602 88-000622 Button Switch Pencil w/Smoke Evacuation Attachment, 10’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-003590 _________ Universal Smoke Evacuation Attachment w/1’ Tubing C\,” Diameter 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-002515 88-002350 Rocker Switch Pencil w/Smoke Evacuation Attachment, 1’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-002516 88-002450 Button Switch Pencil w/Smoke Evacuation Attachment, 1’ Tubing C\,” Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-000611 _________ 5” Extension Tip for Smoke Evac Attachment 1/Pk, 25 Pks/Bx, 1 Bx/CsAll smoke evacuation products are available bulk Non-Sterile by removing initial zeros after the dash and adding “NS” to the end of any product number (Ex: 88-600NS).

SMOKE EVACUATION SYSTEMS & PRODUCTS

“With the current recommendations for our health and safety, the DeRoyal smoke evacuator provides smoke evacuation as close to the surgical site as possible. This, coupled with its ease of use for staff and the minimally disruptive noise for surgeons, made it our hospital’s choice.” -- Teresa Cobleigh, RN, Unit Educator of Surgery, Antelope Valley Hospital, Antelope Valley, CA

Page 19: Make the Right Connection - Henry Schein

19

www.deroyal.com 800.251.9864

M a k e t h e R i g h t C o n n e c t i o n

Smoke Evacuation Tubing & Accessories for Laparoscopic or Laser Procedures• Laparoscopic tubing used in conjunction with Crystal Vision Machine for automatic smoke removal without loss of pneumoperitoneum• Hand-held wand ideal for evacuating smoke during laser procedures• Speculum smoke evac tubing fits on speculum port for hands-free smoke removal using wall suction or machine• Single use only• Latex free

Product No. Description

88-003540 10’ Smoke Evac Extension/Speculum Tubing C\,” Diameter w/Male Barb (Ideal for laser procedures) 88-000695 10’ Laparoscopic Smoke Evac Trocar Tubing for Crystal Vision Smoke Evacuation Units88-000700 Smoke Evacuation Wand, 10’ Tubing, High Flow Filter* 88-000800 Smoke Evacuation Wand, 10’ Tubing88-000801 Micromanipulator Smoke Nozzle 400 mm, w/o Tubing*Must be used only with Crystal Vision Machine. Packaged Sterile 1/Pk, 25 Pks/Bx, 1 Bx/Cs unless otherwise noted.

88-003540 88-00070088-000695

SMOKE EVACUATION SYSTEMS & PRODUCTS

Page 20: Make the Right Connection - Henry Schein

E l e c t r o s u r g i c a l & S m o k e E v a c P r o d u c t s

©2014 DeRoyalReprint # 0-1729Rev. 3/14

DeRoyal Industries, Inc.200 DeBusk LanePowell, TN 37849 USA800.251.9864865.938.7828 or 888.938.7828 www.deroyal.com

ILLEGAL RESTRAINTS OF TRADEDeRoyal electrosurgical products are compatible with any electrosurgical unit on the market, but to be certain and/or to answer any questions the customer

might have regarding compatibility, that customer should inquire with the original manufacturer of the electrosurgical unit being used at the customer’s

facility. Upon any inquiry, the customer may find that some suppliers require purchase of only their accessories as a condition of initial purchase. These

suppliers may also state that warranties and/or guarantees would be otherwise invalidated. Typically, according to the Supreme Court precedent and

federal law, arrangements (in which the sale or support of one product is conditioned upon the purchase or utilization of a separate product from the

same manufacturer/supplier) are often considered to be “tying arrangements” which may constitute an illegal restraint of trade. Clearly, the important

considerations for the customer are the technical and economic comparisons between competing products and DeRoyal electrosurgical products, which are

the finest available.

DEROYAL CUSTOMER INDEMNIFICATION POLICYDeRoyal electrosurgical products carry with them the company’s superior workmanship, materials and design, and the further assurance that reasonable care

was utilized in the manufacture of these products. DeRoyal will replace, at no charge, any electrosurgical products which fail to meet DeRoyal’s standards

of workmanship, materials, or design, although DeRoyal will not be responsible for damage after delivery, due to accident, improper use or abuse; or failure to follow instructions provided by DeRoyal. Included in this replacement policy are electrosurgical generators, if damaged, and such damage proven to

be solely caused by a defective DeRoyal electrosurgical product or the incompatibility of the DeRoyal product with the electrosurgical generator. Finally,

DeRoyal will indemnify the medical facility for any loss or claims for burns proven to be caused by defective DeRoyal electrosurgical products, subject to

the conditions that:

1) The medical facility and its associated personnel have, in all respects and at all times, adhered to the instructions provided by DeRoyal.

2) The medical facility has furnished prompt records of any and all claims of damage allegedly caused by defective DeRoyal electrosurgical products by certified mail to DeRoyal at 200 DeBusk Lane; Powell, TN 37849.

3) The medical facility cooperates fully with DeRoyal to solve the problem, and in the investigation and defense of any claim.

DISCLAIMERInformation provided by DeRoyal to customers and potential customers, treatment and product suggestions, and billing code designations, is provided for

the convenience of our customers and does not constitute medical device.