Magnolia Dam Lake Level Management
Sean Bothelio Project-Operations Manager Lake of the Pines Association January 29th, 2017
![Page 2: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/2.jpg)
Magnolia Dam
Jurisdiction of CA Division of Safety of Dams CA Dam # 1302 / National ID # CA00966
Application # 1300 approved September 8, 1966
‘Guidelines for the Design and Construction of Small Embankment Dams’
Key Elevations 1515’0” - Dam crest and top of second weir
1511’6” - Lowest permissible elevation of permitted building
1510’0” - Bottom of second weir / top of first weir (Flood)
1507’0” - ‘Normal Pool Elevation’ lake level / First spill
1465’0” - Low Level Outlet
![Page 3: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/3.jpg)
CA Division of Safety of Dams
Guidelines for the Design and Construction of Small Embankment Dams
Purpose and Scope: “The purpose of these guidelines is principally to provide those potential owners of small dams with a fairly complete description of the legal and engineering requirements that they must meet if they desire to construct and own a small dam in California”
Chapter V – Outlets: “A low level outlet is required for emptying or lowering the reservoir in case of emergency: for inspection and maintenance of the dam, reservoir, and appurtenances: and for releasing waters to meet downstream water rights”
![Page 4: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/4.jpg)
Lake Level Management
Spillway
Designed to manage lake level and flood control
Uncontrolled double weir ogee design
Low Level Outlet
To be used for emergency drawdown or for dam maintenance
24” Waterman Model SC-50(M) cast iron sluice gate (Modified for 55’ head) with spigot back and bronze seat (circa 1966)
![Page 5: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/5.jpg)
Magnolia Dam Spillway
Double weir ogee design (uncontrolled)
First weir – 3’ x 25’ (10% of overall capacity) Top @ flood stage (1510’)
Second weir – 5’ x 150’
Built for 1,000 yr storm
![Page 6: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/6.jpg)
Low Level Outlet (LLO)
Steel liner w/21.5” ID installed 1994 (24” originally)
0.28% cross-section of spillway (less than 1/3 of one per cent)
Reduced capacity ~30%
Approx 45’ under normal lake level
![Page 7: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/7.jpg)
Laminar Flow • Occurs when a fluid flows in parallel layers
• Desired outcome in most situations, especially when trying to move fluids
– Spillway/Weir
Turbulent Flow • Characterized by chaotic changes in pressure
and flow velocity
• Most applications turbulence is undesirable when trying to move fluids
– Valves
Types of Flow
By Gary Settles - Own work, CC BY-SA 3.0
Laminar Flow
Turbulent Flow
![Page 8: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/8.jpg)
Gate Valve (Sluice)
Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves should NOT be used for regulating flow, unless they are specifically designed for that purpose.
A partially open sluice gate tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing gate and seat wear and eventual leakage if used to regulate flow.
Designed for full open/closed applications
![Page 9: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/9.jpg)
Gate Valve (Sluice)
As the gate closes, the wedges pull the top and bottom seats into contact.
Gate out of turbulent flow when fully open
Extended partial openings lead to
excessive wear/damage due to vibrations from
turbulence
![Page 10: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/10.jpg)
Gate Valve (Sluice)
As the gate moves, the wedges pull the top and bottom seats into contact
This concern has been confirmed by every expert/professional we
have consulted with
Lake and Parks Committee Members Lake of the Pines Assoc
Principal Mechanical Engineer
Waterman USA
Dam Safety Engineer Nevada Irrigation District
Regional Engineer
CA Division of Safety of Dams
“We found leakage in-between the gate frame and the concrete as well as
on the sealing surfaces itself.”
Big Valley Divers 24” Sluice Gate Inspection Report
Very basics of fluid dynamics prove ‘Turbulent Flow’ introduced into
valve by the extended partial opening of valve resulting in
vibrations of gate in any position other than full open or full closed
![Page 11: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/11.jpg)
Using LLO considerations
Downstream Considerations
Flooding member’s properties
Downstream culverts capacities
Spillway vs LLO capacities
Spillway is designed for level management
Capacity is immensely greater than LLO
LLO very little impact on lake level during storm
![Page 12: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/12.jpg)
Downstream Considerations
Overflow onto Combie Rd, possible erosion of road.
Confluence of Magnolia Creek and spillway/8th fairway drainage
Overflow onto TPD & possible erosion of road.
Culvert at Torrey Pines and Magnolia Creek
Flooding
Properties on Acacia and Maple Courts
![Page 13: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/13.jpg)
Flooding – Acacia/Maple Cts
Magnolia Creek can reach maximum capacity with dam
release and rain runoff, additional groundwater pressure can lead to
flooding of properties
![Page 14: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/14.jpg)
Culvert at Torrey Pines
Once culvert is max’d out the creek begins to backup flooding properties, overflow TPD, and
possible erosion of road
Culvert under TPD can only handle so much dam release
and rain runoff
![Page 15: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/15.jpg)
Confluence @ Combie Rd
Confluence of Magnolia Creek and spillway/8th fairway drainage then
under Combie Rd
Once culvert is max’d out the creek begins to backup and
overflows onto Combie Rd and possible erosion of road
![Page 16: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/16.jpg)
Formulas for Modeling
![Page 17: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/17.jpg)
Spillway
• Weir structure (T shape) is 190’W x 12’H x 180’L
– Weir has cross-section of 118,800 sq in
– Promotes laminar flow = greater flow
1st weir has >32x the cross-section of LL0
2nd weir has cross section of 108,000 sq in
LLO has cross section of 330 sq in
1st weir has cross section of 10,800 sq in
12,900,000 GPH before reaching flood
![Page 18: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/18.jpg)
0
50000
100000
150000
200000
250000
1507' 00" 1507' 3.6" 1507' 7.2" 1507' 10.8" 1508' 2.4" 1508' 6.0" 1508' 9.6 1509' 1.2" 1509' 4.8" 1509' 8.4" 1510' 00"
Weir GPM
Valve GPM Max
Valve GPM@10"
Valve GPM@8"
Valve GPM@6"
Valve GPM@4"
1st weir reached 50% capacity Tues Jan 10th @ ~8pm
The equivalent volume of water between the spillway and 6” below
was discharged through the
spillway in just over 4 hours
Spillway(1st weir) vs LLO Efficiency
Highest lake level during storm, ~ 60% of
spillway capacity receded 12” < 12 hours
Gal
lon
Per
Min
ute
Lake Level
![Page 19: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/19.jpg)
Summary
• The Low Level Outlet is not intended to manage lake level, nor is the gate valve designed for that purpose – Although the new LLO being built is better designed for partial
openings, it still is not intended for lake level management,
• The longstanding belief the lake level can be effectively managed is unfounded, and it is NOT feasible to maintain the lake within +/- 6 inches – The LLO outlet discharge is not as effective as the spillway – Six inches below the spillway does NOT equal six inches lower
lake level after the lake level is above the spillway for a period of time
![Page 20: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/20.jpg)
Questions
If you would like more information regarding LOP Member Ross Tokmakian’s presentation of “LOP Lake Level Analysis,” please refer to the Pinesmen website
or by following the provided link.
![Page 21: Magnolia Dam Lake Level Management level management... · 2017-02-01 · Magnolia Dam Lake Level Management Sean Bothelio Project-Operations Manager ... The equivalent volume of water](https://reader033.fdocuments.in/reader033/viewer/2022052721/5f0b1d1b7e708231d42eea6f/html5/thumbnails/21.jpg)
References
• CA Division of Safety of Dams (DSOD) – Conversations with the Regional Engineers and Inspector – ‘Guidelines for the Design and Construction of Small Embankment Dams’ March 1977 and reprinted January 1993 – Western Lake Properties Application Number 1300 for Magnolia Dam to CA Division of Safety of Dams approved Sept 8, 1966 – CA Division of Safety of Dams approved plans for Magnolia Dam – ‘Inspection of Dam and Reservoir in Certified Status’ dated July 22, 2016
• Nevada Irrigation District – Ongoing communication with their Operations Manager and Dam Safety Engineer, – Onsite visit by their Operations Manager and Dam Safety Engineer
• Waterman USA – Original valve documentation – Conversations with their Principal Mechanical Engineer and Senior Project Manager
• County of Nevada – Board of Supervisors Ordinance # #2234 – Planning Department Zoning District Map 59
• Big Valley Divers Inc – Ongoing communication with their diver on-site – ‘24” Sluice Gate Inspection Report’ dated June 12, 2015
• FEMA National Dam Safety Program • U. S. Department of the Interior, Bureau of Reclamation, WATER MEASUREMENT MANUAL • San Diego State University http://ponce.sdsu.edu/ • United States Society on Dams (USSD)