M60 My White LED Direct Tunable White [L60] selux
Transcript of M60 My White LED Direct Tunable White [L60] selux
Page 1 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Project:
Type: Qty:
Date: Customer:
M60 My WhiteLED Direct Tunable White
Order Code: - - - - - - - -
Dimming Options
Emergency Options
EC7 Emergency Circuit Wiring
DL3 Damp Location Rated
FS3 In-line Fuse
SS3,4 Separate Switching
Fixture Options
- -
WC5 Wall Controller Connections
7 See page 9 for full details and restrictions
LED WARRANTY
5YEAR ARRA
CompliantADA
CompliantBUY AMERICAN
DMX6 eldoLED POWERdrive DMX (Linear)
DMW6 eldoLED 1% DUALdrive DALI (Linear)
DTW6 eldoLED SOLOdrive 0-10V LightShape (linear)
DLL6 eldoLED DALI (Logarithmic) Dimming (Linear) CCT balance
DMT Lutron T-Series for Quantum Controls only (consult factory)
Series L60 M60 LED Direct
Nominal Fixture Length
02 2 ft.
04 4 ft.
03 3 ft.
05 5 ft.
06 6 ft.
08 8 ft.
07 7 ft.
XX Runs (over 12’), round up to the nearest foot and replace the “xx” with the # (i.e. 13=13’ nominal)
Finish WH White
SV Silver
Voltage
1Must be a minimum of 2 ft.
L60
L60
09 9 ft.
11 11 ft.
10 10 ft.
12 12 ft.
* Custom colors are available, Please consult factory
SP Specify Premium Color
BL Semi-Matte Black
120120V
277277V
UNV120V thru 277V 50/60hz capable
Light Engine
CCT
Shielding
Mounting F2 Surface Mount
C Cable
S Swivel Stem
RS Rigid Stem
W2 Wall Mount
2 Over 8’ supplied with 2 or more housings that are joined in the field.
1 Average values calculated from a 4’ fixture with CLL using LW Shielding and DMX driver. For additional information please see page 2.
Individual fixtures and Runs are supplied in nominal lengths to ensure full, even, illumination. See pages 2 through 6 for additional details.
6 See page 7-8 for full details
1A32 TW
1A32
TW TW Tunable White - 2700K through 6500K 90+ CRI
1A321 532lm/8.1W per foot
MI Clear Lens with Microprism
NB LMO Symmetric with Satine Lens
A2 LMO Asymmetric 20° Wall Washer with Satine Lens
BW LMO Batwing with Satine Lens
A5 LMO Asymmetric 5° Wall Grazer with Satine Lens
LW LED Optimized White Lens
3 For DMX, please consult factory. See page 9 for full details and restrictions
4 See page 9 for details5 For use with DMX only. See page 2 for details.
Page 2 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Construction:
Housing - Continuous, low copper 6063-T6 ex-truded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 12’) or Runs.
Geartray - Low copper 6063-T6 extruded aluminum profile.
Shielding - Extruded, impact resistant acrylic lens:- LED Optimized White Lens (LW)- Clear Lens with Microprism (MI)“LMO” refers to the Selux proprietary LED optical system - Light modulation optics. These lenses are offered in M60 behind a Satine Lens for even illumination and comfortable lit appearance.- “LMO” Symmetric Lens (NB) - “LMO” Asymmetric 20° Wall Washer (A2)- “LMO” Asymmetric 5° Wall Grazer (A5)- “LMO” Batwing (BW)
Mounting(s) - 1/16” Aircraft Cable, Ø5/8” Swivel or Rigid Steel Stem, Wall Bracket, Surface mounting (see pages 3 thru 6 for details).**Cable, Stem and Wall mountings may not be symmetrical for Runs due to the use of modular housing lengths. If symmetrical suspensions are required please consult the factory.
Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs are available in ap-proximately 1’ increments starting at the nominal 12’ fixture length. ** Individual luminaires are not joinable in the field.
Exact length luminaires - Individual luminaires and Runs are available in exact lengths to meet your project needs. Please consult factory with your requirements. **Lens luminance may soften at the very ends of the straight sections for exact length luminaires.
L60 Joiner(s) - Runs are supplied in multiple hous-ing that are joined together in the field using the supplied L60 Joiner System. This allows ease of installation and ensures a uniform appearance (see page 8 for detail).
Electrical/Performance:
Constant Lumen Level (CLL) Curve – Selux rec-ommends utilizing the Constant Lumen Level (CLL) curve for the My White product. This is achieved using an algorithm programmed into the controls for driving the two channels of the driver simulta-neously so that while adjusting the CCT, the lumen output remains the same. For recommended controls for CLL, please consult Selux.
Max Output – If the Constant Lumen Level (CLL) setting is not used, a higher light level may be achieved towards the center of the color tuning range. However, since this method is not pro-grammed, and due to the self-protection of the driver, the results may fluctuate and are uncertain. See chart on page 9 for details.
LED Light Engine – Brand-name mid-power LEDs create a high efficiency LED light engine with a re-ported luminous flux maintenance at 60,000 hours of 88% based on LM-80 test reports. The rated lumen maintenance life is L70 (10k) > 60,000 hours. Luminous flux values calculated in accordance to TM-21 procedures based on LM-80 compliant reported measurement data. For Title 24 compliant model numbers, please consult factory.
Photometrics – Consult website or factory for IES Files. Photometric lumen measurement complies with IES LM-79-08 testing procedures. Due to the LED manufacturer’s tolerances, the listed output has a ±5% tolerance.
Delivered Lumens - Due to LED manufacturer’s tolerances the listed output has a ±5% tolerance.
CCT - Tunable CCT from 2700K thru 6500K tolerance within a 3-step MacAdam Ellipse.
CRI - 90+.
Driver - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 7.
Wall Controller - Optional wall controller can be ordered for use with DMX fixtures. See DMX control-ler spec sheet for more details.
Thermal Performance:
Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of35°C (95°F). Minimum ambient temperature of -20°C (-4°F).
Luminaire Finish:
Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accor-dance with test specifications for coatings from ASTM and PCI.
All products undergo a five stage intensive pre-treatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humid-ity resistance as well as ultraviolet resistance for color retention.
Standard interior colors are White (WH), Semi-Matte Black (BL) and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.
Warranty:
5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original pur-chaser that the M60 MyWhite LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instruc-tions and operated within the Ambient Tempera-ture. For additional details and exclusions, see “Selux Terms and Condition of Sale.”
Certifications and Compliance: NRTL - For Dry and Damp location (I.E. cULus)ARRA CompliantRoHS Compliant
3 9/16” (91mm)
2 1/4” (56mm)
2 3/8” (60mm)
Page 3 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Cable Mounting (C)
1/4”- 20 Threaded Rod (supplied & installed in the field by others)
1. Ø 1/16” Aircraft Cable with chrome gripper for easy adjustment (48” max. from ceiling to luminaire).
1/4”-20 Slip ring coupler
1/16” Aircraft cable
Chrome gripper
Luminaire
1/4” x 2” diameter Canopy (white)
Cable Mounting (C) - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.) End Suspensions
“C” Mid. Suspension
“D” Power Feed Location
“E” DMX In/Out
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2 ft.) 2' - 1/4" 616 0' - 2 1/8” 54 1' - 8" 508 0’ - 1 1/8” 29 0’ - 1 1/8” 29
03 (3 ft.) 3' - 5/16" 923 0' - 3 1/8" 79 2' - 6 1/8" 764 0' - 2 1/8" 54 0' - 2 1/8" 54
04 (4 ft.) 3' - 11 7/16" 1205 0' - 3 1/8" 79 3' - 5 3/16" 1047 0' - 2 1/8" 54 0' - 2 1/8" 54
05 (5 ft.) 4' - 11 7/16" 1510 0' - 3 1/8" 79 4' - 5 3/16" 1351 0' - 2 1/8" 54 0' - 2 1/8" 54
06 (6 ft.) 5' - 11 7/16" 1815 0' - 3 1/8" 79 5' - 5 3/16" 1656 0' - 2 1/8" 54 0' - 2 1/8" 54
07 (7 ft.) 6' - 11 7/16" 2119 0' - 3 1/8" 79 6' - 5 3/16" 1961 0' - 2 1/8" 54 0' - 2 1/8" 54
08 (8 ft.) 7' - 11 7/16" 2424 0' - 3 1/8" 79 7' - 5 3/16" 2266 0' - 2 1/8" 54 0' - 2 1/8" 54
09 (9 ft.) 8' - 11 7/16" 2729 0' - 3 1/8" 79 8' - 5 3/16" 2570 0' - 2 1/8" 54 0' - 2 1/8" 54
10 (10 ft.) 9' - 11 7/16" 3034 0' - 3 1/8" 79 9' - 5 3/16" 2875 0' - 2 1/8" 54 0' - 2 1/8" 54
11 (11 ft.) 10' - 11 7/16" 3339 0' - 3 1/8" 79 10' - 5 3/16" 3180 0' - 2 1/8" 54 0' - 2 1/8" 54
12 (12 ft.) 11' - 11 7/16" 3643 0' - 3 1/8" 79 11' - 5 3/16" 3485 0' - 2 1/8" 54 0' - 2 1/8" 54
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
Cable Mounting (C)
Power Feed DMX In/Out
Power Feed DMX In/Out
SideView
BottomView
CeilingOutlet box for feed only (by others)
Cross bar with 1/4”-20 rod and ground screw
1/4” x 5” diameter canopy (White)
2x White cable stay
Cord strain relief bushing
2x Outlet box screws (by others)
1/4”-20 Slip ring coupler
Feed cord (White)
1/16” Aircraft cable
Chrome gripper
Luminaire
Outlet box for feed only (by others)
Cross bar with 1/4-20 rod and ground screw
1/4” x 5” diameter canopy (White)
2x White cable stay
Cable Grommet
Chrome gripper
2x Outlet box screws (by others)
1/4-20 Slip ring coupler
1/16” Aircraft cable
Outlet box for feed only.(By Others)Cross bar w/ 1/4-20rod and ground screw
1/4" x 5" dia. canopy.(White)Cable Grommet1/4-20 Slipring couplerDMX Cables (White)1/16" Aircraft cable2x White cable stayChrome gripperLuminaire
2x Outlet box screws(by others)
Cable Grommet
DMX cables (White)
Cable Grommet
luminaire
L6DI Cable (C) Suspension Detail (Power Feed location(s) only)
L6DI Cable (C) Suspension Detail (Non-Feed location(s) only)
L60 Cable (C) Suspension Detail (DMX Feed location(s) only)
Min. 5/8” toMax. 3/4”
Page 4 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Stem Mounting (S & RS)
Outlet box (supplied & installed by others)
L60 Swivel Stem (S) Suspension Detail (feed wires through stem supplied by Selux)
L60 Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by Selux)
3/8”IP Cross bar with ground screws
Hemispherical assembly
1 7/16” x 5” diameter canopy (white)
1. Ø 5/8” Swivel Stem provides 30° swivel and can be cut in field (48” max. from ceiling to luminaire).
2. Ø 5/8” Rigid Stem is fixed and is not able to be cut/adjusted in field (48” max. from ceiling to luminaire).
Pin
3/8” IP steel stem (white)
Dress nut
Square nut
Luminaire
Outlet box (supplied & installed by others)
3/8 IP nipple (supplied & installed by others)
Suspension hickey
Canopy securing screw
1/4” x 5” diameter canopy (white)
Swivel (S) & Rigid Stem (RS) Mountings - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.) End Suspensions
“C” Mid. Suspension
“D” Power Feed Location
“E” DMX In/Out
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2 ft.) 2' - 1/4" 616 0' - 2 1/8" 54 1' - 8" 508 0' - 2 1/8" 54 0' - 2 1/8" 54
03 (3 ft.) 3' - 5/16" 923 0' - 3 1/8" 79 2' - 6 1/8" 764 0' - 3 1/8" 79 0' - 3 1/8" 79
04 (4 ft.) 3' - 11 7/16" 1205 0' - 3 1/8" 79 3' - 5 3/16" 1047 0' - 3 1/8" 79 0' - 3 1/8" 79
05 (5 ft.) 4' - 11 7/16" 1510 0' - 3 1/8" 79 4' - 5 3/16" 1351 0' - 3 1/8" 79 0' - 3 1/8" 79
06 (6 ft.) 5' - 11 7/16" 1815 0' - 3 1/8" 79 5' - 5 3/16" 1656 0' - 3 1/8" 79 0' - 3 1/8" 79
07 (7 ft.) 6' - 11 7/16" 2119 0' - 3 1/8" 79 6' - 5 3/16" 1961 0' - 3 1/8" 79 0' - 3 1/8" 79
08 (8 ft.) 7' - 11 7/16" 2424 0' - 3 1/8" 79 7' - 5 3/16" 2266 0' - 3 1/8" 79 0' - 3 1/8" 79
09 (9 ft.) 8' - 11 7/16" 2729 0' - 3 1/8" 79 8' - 5 3/16" 2570 0' - 3 1/8" 79 0' - 3 1/8" 79
10 (10 ft.) 9' - 11 7/16" 3034 0' - 3 1/8" 79 9' - 5 3/16" 2875 0' - 3 1/8" 79 0' - 3 1/8" 79
11 (11 ft.) 10' - 11 7/16" 3339 0' - 3 1/8" 79 10' - 5 3/16" 3180 0' - 3 1/8" 79 0' - 3 1/8" 79
12 (12 ft.) 11' - 11 7/16" 3643 0' - 3 1/8" 79 11' - 5 3/16" 3485 0' - 3 1/8" 79 0' - 3 1/8" 79
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
Stem Mounting (S & RS)
Luminaire
Dress nut
Square nut
Square nut
Square nut
3/8” IP steel stem (white)
Power Feed
SideView
BottomView
DMX In/Out
Power Feed DMX In/Out
Page 5 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Wall Mounting (W)
1. Aluminum wall bracket (by Selux).2. 4”x4” or 2”x4” J-box at feed location (supplied and
installed by others).3. 1/4”-20 Threaded rod, 1/4”-20 lock washer and 1/4”-20 nut required
to anchor the wall bracket. Mounting hardware supplied and installed to code by others.
Wall Mount (W) (Covers a 4x4 or 2x4 J-box)
Wall (W) Mount - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.) End Suspensions
“C” Mid. Suspension
“D” Power Feed Location
“E” DMX In/Out
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2 ft.) 2' - 1/4" 616 0' - 3 1/8" 79 1' - 6 1/16" 458 0' - 3 1/8" 79 0' - 3 1/8" 79
03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 2' - 1/8" 612 0' - 6 1/8" 156 0' - 6 1/8" 156
04 (4 ft.) 3' - 11 7/16" 1205 0' - 6 1/8" 156 2' - 11 3/16" 894 0' - 6 1/8" 156 0' - 6 1/8" 156
05 (5 ft.) 4' - 11 7/16" 1510 0' - 6 1/8" 156 3' - 11 3/16" 1199 0' - 6 1/8" 156 0' - 6 1/8" 156
06 (6 ft.) 5' - 11 7/16" 1815 0' - 6 1/8" 156 4' - 11 3/16" 1504 0' - 6 1/8" 156 0' - 6 1/8" 156
07 (7 ft.) 6' - 11 7/16" 2119 0' - 6 1/8" 156 5' - 11 3/16" 1808 0' - 6 1/8" 156 0' - 6 1/8" 156
08 (8 ft.) 7' - 11 7/16" 2424 0' - 6 1/8" 156 6' - 11 3/16" 2113 0' - 6 1/8" 156 0' - 6 1/8" 156
09 (9 ft.) 8' - 11 7/16" 2729 0' - 6 1/8" 156 7' - 11 3/16" 2418 0' - 6 1/8" 156 0' - 6 1/8" 156
10 (10 ft.) 9' - 11 7/16" 3034 0' - 6 1/8" 156 8' - 11 3/16" 2723 0' - 6 1/8" 156 0' - 6 1/8" 156
11 (11 ft.) 10' - 11 7/16" 3339 0' - 6 1/8" 156 9' - 11 3/16" 3028 0' - 6 1/8" 156 0' - 6 1/8" 156
12 (12 ft.) 11' - 11 7/16" 3643 0' - 6 1/8" 156 10' - 11 3/16" 3332 0' - 6 1/8" 156 0' - 6 1/8" 156
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
4” (102mm)
1” (25mm)
3 3/8”
(85mm)
4” (102mm)
SideView
BottomView
Power Feed DMX In/Out
Page 6 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Surface Mounting (F) - 1’ to 8’
1. Ø 5/16” Mounting hole drilled at the factory (mounting hardware to code by others).
Surface Mounting (F) - Over 9’ to 12’
Surface Mount (F)
* Please note: Fixture does not cover a 4x4 J-box
Surface Mount (F) - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.) End Suspensions
* “B1” End Suspensions
“C” Mid. Suspension
“C1” Mid. Suspension
“C2” Mid. Suspension
“D” Feed Location
“E” DMX In/Out
Feet/Inch MM Feet/Inch MM Feet/Inch
MM Feet/Inch MM Feet/Inch MM Feet/Inch
MM Feet/Inch MM Feet/Inch MM
02 (2 ft.) 2' - 1/4" 616 0' - 1 5/8" 41 N/A 1' - 9" 534 N/A N/A 0' - 4 1/8" 105 0' - 4 1/8" 105
03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 N/A 2' - 1/8" 612 N/A N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
04 (4 ft.) 3' - 11 7/16" 1205 0' - 6 1/8" 156 N/A 2' - 11 3/16" 894 N/A N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
05 (5 ft.) 4' - 11 /16" 1510 0' - 6 1/8" 156 N/A 3' - 11 3/16" 1199 N/A N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
06 (6 ft.) 5' - 11 7/16" 1815 0' - 6 1/8" 156 N/A 3 '- 0” 914 1' - 11 3/16" 590 N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
07 (7 ft.) 6' - 11 7/16" 2119 0' - 6 1/8" 156 N/A 3'’- 0” 914 2' - 11 3/16" 894 N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
08 (8 ft.) 7' - 11 7/16" 2424 0' - 6 1/8" 156 N/A 3'’- 0” 914 3' - 11 3/16" 1199 N/A 0' - 2 1/8" 54 0' - 2 1/8" 54
09 (9 ft.) 8' - 11 7/16" 2729 0' - 6 1/8" 156 0' - 6" 153 3' - 11 3/16" 1199 NA 3'’- 0” 914 0' - 2 1/8" 54 0' - 2 1/8" 54
10 (10 ft.) 9' - 11 7/16" 3034 0' - 6 1/8" 156 0' - 6" 153 3'’- 0” 914 1' - 11 3/16" 590 3' ‘- 0” 914 0' - 2 1/8" 54 0' - 2 1/8" 54
11 (11 ft.) 10' - 11 7/16" 3338 0' - 6 1/8" 156 0' - 6" 153 3'’- 0” 914 2' - 11 3/16" 894 3' ‘- 0” 914 0' - 2 1/8" 54 0' - 2 1/8" 54
12 (12 ft.) 11' - 11 7/16" 3643 0' - 6 1/8" 156 0' - 6" 153 3' ‘- 0” 914 3' - 11 3/16" 1199 3'’- 0” 914 0' - 2 1/8" 54 0' - 2 1/8" 54
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
"D" POWER FEED
"C"
"B" "B"
"A"
"C" "C1"
"E" DMX IN
"C"
"B" "B""C" "C1" "C2" "B"
"D" POWER FEED
"A"
"E" DMX
SIDEVIEW
BOTTOMVIEW
SIDEVIEW
BOTTOMVIEW
Side View
BottomView
Side View
BottomView
Page 7 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Driver Quantity (consult factory for SS option driver quantity)
2 ft. 3 ft. 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. RUN
DLL/DTW/DMW/DMX drivers 1 1 1 2 2 2 2 3 3 3 3Approximately 1 driver per 4 ft.
eldoLED Dimming Driver:
Wiring Diagrams
Dimming - DMX eldoLED POWERdrive (DMX) (Individual fixtures)
Feed(Power) Driver
GreenWhiteBlack
DMX
DMX = supplied with a DMX in and DMX outcontrol cables. DMX out control cable is suppliedwith a removable end of run termination resistor*.
*When the DMX system is being commissioned the installer to remove the resistors as needed to group fixtures.
DMX inDMX out
DMX - Feed
Driver
GreenWhiteBlack
Driver
DMX inDMX out
DMX - Feed
Feed(Power)
Dimming - DMX eldoLED POWERdrive (DMX) (Runs)
Connection in field(by others)
GreenWhiteBlack
see DMX connector detail
Supplied connector (DMX in)(3 position connector, 28-12 ga. 300v 10A)
see DMX connector detail
Supplied termination resistor
DMX connector detail
Supplied connector (DMX out)(3 position connector, 28-12 ga. 300v 10A)
connectors suppliedand wired by Selux
DALI Linear (DMW) / DALI Log (DLL) / 0-10V Lin (DTW)
DMWDLLDTW
eldoLED DALI dimming (DMW) Luminaires supplied with DUALdrive DALI dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.
eldo DMX dimming (DMX) Luminaires supplied with POWERdrive DMX dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory. Selux recommends a maximum of 31 drivers in a DMX universe. DMX fixtures can be grouped together (remove the termination resistor at the end of the fixture and connect the DMX cable from the next fixture).
*By default, all drivers on a job will be set to the same address. For additional addressing options, please consult factory.
*For inrush and control current, please refer to the driver manufacturers’ spec sheets.
eldoLED DALI LightShape dimming (DLL) Luminaires supplied with DUALdrive DALI dimming driver for eldo Light-Shape tunable white technology. Tunable white allows dim to dark with the addition of adjustable color temperature to reduce nature’s auras.
eldoLED 0-10V LightShape dimming (DTW) Luminaires supplied with SOLOdrive 0-10V, single channel dim to dark dimming driver with LightShape Dim to Warm technology. Dim to Warm warms the color temperature as the luminaire dims.
*For control recommendations for eldoLED drivers, please contact eldoLED.
Page 8 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 My WhiteLED Direct
Wiring Diagrams
DMX CABLE
TERMINATION RESISTOR
HOUSING, MIDHOUSING, END
HOUSING, INDIVIDUAL/START
DMX FEED1
2POWER FEED
BLACK
WHITE
GREEN
TERMINATION RESISTOR
DMX FEEDPOWER FEED
WHEN DAISY CHANING FIXTURES, REMOVE TERMINATION RESISTOR AND CONNECT DMX
OUT CABLE
4BLACK
WHITE
GREEN
BARE - SHIELD
BLACK - DMX NEGATIVE
WHITE - DMX POSITIVE
BLACK
WHITE
BARE
3 POSITION MALE CONNECTOR
BARE
WHITE
BLACK
3 POSITION FEMALE CONNECTOR
BLACK WHITE BARE
4 POSITION MALE CONNECTOR
BARE WHITE BLACK
4 POSITION FEMALE CONNECTOR
21
DMX dimming (DMX)
3
43
2 1 12
4
4
3
3
34
21
When Daisy Chaining �xtures, remove termination resistor and connect DMX out cable.
CABLE
DMX CABLE
SINGLE SECTION LUMINAIRE
LED DRIVER
LED DRIVER LED DRIVER LED DRIVER
DMX OUT
DMX IN
DMX IN
DMX OUT
DMX OUT
DMX IN
DMX IN
DMX OUT
DMX OUT
DMX IN
CABLE
MULTI SECTION LUMINAIRE
DMX FEED CABLE
DO NOT GROUND SHIELD IN LUMINAIRE. ONLY CONNECT SHIELD AT CONTROLLER.
3 POSITION FEMALE CONNECTOR WITH TERMINATION CONNECTOR.
DO NOT USE120 V1/4 W
DMX SIGNAL CONNECTORS
CONNECTORS USED FOR CONTROLLER CONNECTION AND TERMINATION RESISTOR CONNECTION.
CONNECTORS USED BETWEEN LUMINAIRE SECTIONS.
Page 9 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse).
Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing.
Separate Switching (SS) - Luminaires available with separately switched 4’ (nominal) sections starting at 7’ and up. Luminaire is in-tended to be wired to the same panel/breaker (not intended for Emer-gency use).
* All separately switched (non-EM) circuits within an individual luminaire, linear run, or configuration must be connected to the same branch circuit on-site.
* To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order.
* If the project requires different separate switching than outlined abov-please consult the factory.
Emergency Circuit (EC) - Luminaires with EC option compliant to UL 924 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use.
- For 1’ to 6’ nominal luminaires, the entire fixture is wired for operation on emergency circuit.
- For 7’ and up nominal luminaires, the first 4’ nominal length is wired for operation by a separate EM circuit by default to meet the required “Life Safety Code” (NFPA 101).
*If a different configuration is needed please consult the factory.
Joiner System - standard for Runs
M60 My WhiteLED Direct
Page 10 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
LW - LED Optimized White Lens
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2127 532 8 66
MI - Clear Lens with Microprism Inlay
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2467 617 8 76
NB - LMO Symmetric
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2276 569 8 70
A2 - LMO Asymmetric 20° Wall Washer
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2297 574 8 71
A5 - LMO Asymmetric 5° Wall Grazer
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2340 585 8 72
BW - LMO Batwing
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1A32 2127 532 8 66
Lens multipliers supplied for per foot values listed on page 1 (light engine).
M60 My White Direct
Lens Multiplier
LW 1.00
MI 1.02
NB 1.22
A2 1.26
A5 1.26
BW 1.00
M60 My WhiteLED Direct
Page 11 of 11 (Rev. 01/2021)
L60_MW_SS_v2.2
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Photometry
M60 My WhiteLED Direct
This photometry can be used for all CCTs when utilizing the constant lumen level (CLL) curve for My White. For other outputs, please consult the factory.
My White and the Circadian Rhythm – Humans have an internal clock that affects everything from sleep patterns to productivity to health. This clock is called the circadian rhythm. As humans evolved in the days before electric lighting, they had natural exposure to various levels (both color temperature and intensity) from the sun. By adjusting electric lighting to mimic the natural hue and intensity of the sun, it can help restore the body to a natural state. Various studies have shown that this can help with alertness, behavioral issues, and productivity. The Selux proprietary My White technology allows you to adjust both the amount and color of your light, creating a comfortable environment for offices, educational facilities, hospitality, or any other installation where varying light could benefit the occupants. Set up the My White luminaires to a whole building solution, and you could create an automatic adjustment to the light to mimic daylight.
2700K 6500KCCT
CONSTANT LUMEN LEVEL
LUMEN OUTPUT BASED ON CONTROL SETTINGS
MAX OUTPUT LEVEL
RECOMMENDED AREA OF OPERATION (CONSTANT LUMEN LEVEL [CLL] SETTINGS)
ADDITIONAL LUMEN ADJUSTABILITY USING MAX OUTPUT CURVEResults may fluctuate when fixture is used outside of the Constant Lumen Level curve.
Driver may limit output above this line
Recommended area of operation (Constant Lumen Level [CCL] settings).