APPLIES TO INDOOR UNIT:□ SEZ-KD18NA4.TH□ SEZ-KD18NAR1.TH□ SEZ-KD18NA4R1.TH
APPLIES TO OUTDOOR UNIT:□ SUZ-KA18NA□ SUZ-KA18NAR1
INDOOR UNIT FEATURES• Concealed horizontal-ducted unit for applications with short duct runs• Quiet operation• Ultra-thin body: 7-7/8" high• Built-in condensate lift mechanism (lifts to 21-21/32")• Multiple control options available:
- kumo cloud® smart device app for remote access- Third-party interface options- Wired or wireless controllers
• Static capability up to 0.20 in. WG
OUTDOOR UNIT FEATURES• Variable speed INVERTER-driven compressor• Innovative Joint Lap DC Motor leads to high efficiency and reliability• Pulse Amplitude Modulation technology• High-performance grooved piping for increased heat exchange efficiency
SUBMITTAL DATA: SEZ-KD18NA4 & SUZ-KA18NA18,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEMS
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
M-SERIES
Cooling1
Maximum Capacity Btu/h 19,000
Rated Capacity Btu/h 17,200
Minimum Capacity Btu/h 3,800
Maximum Power Input W 1,460
Rated Power Input W 1,380
Moisture Removal Pints/h 3.4
Sensible Heat Factor 0.79
Power Factor % 97/97
Heating at 47°F2
Maximum Capacity Btu/h 24,900
Rated Capacity Btu/h 21,600
Minimum Capacity Btu/h 4,800
Maximum Power Input W 2,230
Rated Power Input W 1,700
Power Factor % 98/98
Heating at 17°F3
Maximum Capacity Btu/h 15,000
Rated Capacity Btu/h 13,100
Maximum Power Input W 1,830
Rated Power Input W 1,350
Heating at 5°F4Maximum Capacity Btu/h 11,600
Maximum Power Input W 1,400
Efficiency
SEER 17.5
EER1 12.5
HSPF (IV) 10.0
COP at 47°F2 3.72
COP at 17°F in Maximum Capacity3 2.40
COP at 5°F in Maximum Capacity4 2.43
ENERGY STAR® (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.)
YES
Electrical
Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz
Guaranteed Voltage Range V AC 187-253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Voltage: Indoor - Remote Controller V DC 12
Recommended Fuse/Breaker Size A 15
Recommended Wire Size (Indoor - Outdoor) AWG 14
Indoor Unit
MCA A 1
MOCP A 15
Blower Motor Full Load Amperage A 0.74
Blower Motor Output W 96
Airflow Rate at Cooling, Dry CFM 635-529-423
Airflow Rate at Cooling, Wet CFM 572-476-381
SPECIFICATIONS: SEZ-KD18NA4 & SUZ-KA18NA
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Airflow Rate at Heating, Dry CFM 635-529-423
Sound Pressure Level (Cooling) dB(A) 38-34-30
Sound Pressure Level (Heating) dB(A) 38-34-30
External Static Pressure in.WG 0.02-0.06-0.14-0.20
Drain Pipe Size In. (mm) 1 1/4 (32)
Condensate Lift Mechanism, Maximum Distance In. (mm) 21-21/32 (550)
Heat Exchanger Type Plate fin coil
External Finish Color Galvanized
Unit Dimensions
W: In. (mm) 46 7/8 (1,190)
D: In. (mm) 27 9/16 (700)
H: In. (mm) 7 7/8 (200)
Package Dimensions
W: In. (mm) 55 1/8 (1,400)
D: In. (mm) 35 7/16 (900)
H: In. (mm) 14 3/16 (360)
Unit Weight Lbs. (kg) 62 (28)
Package Weight Lbs. (kg) 90 (41)
Indoor Unit OperatingTemperature Range
Cooling Intake Air Temp (Maximum / Minimum)* °F 95 DB / 71 WB // 67 DB / 57 WB
Heating Intake Air Temp (Maximum / Minimum) °F 80 DB // 70 DB
Outdoor Unit
MCA A 14
MOCP A 15
Fan Motor Full Load Amperage A 0.93
Fan Motor Output W 77
Airflow Rate CFM 1,730 / 1,659
Refrigerant Control LEV
Defrost Method Reverse cycle
Heat Exchanger Type Plate fin coil
Sound Pressure Level, Cooling1 dB(A) 54
Sound Pressure Level, Heating2 dB(A) 56
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model SNB130FQBH
Compressor Rated Load Amps A 10.0
Compressor Locked Rotor Amps A 12.5
Compressor Oil Type // Charge oz. NEO22 // 15.2
External Finish Color Munsell 3Y 7.8/1/1
Base Pan Heater Optional (MAC-642BH-U1)
Unit Dimensions
W: In. (mm) 33-1/16 (840)
D: In. (mm) 13 (330)
H: In. (mm) 33-7/16 (850)
Package Dimensions
W: In. (mm) 40 (1,020)
D: In. (mm) 18-1/2 (470)
H: In. (mm) 39 (990)
SPECIFICATIONS: SEZ-KD18NA4 & SUZ-KA18NA
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Unit Weight Lbs. (kg) 119 (54)
Package Weight Lbs. (kg) 146 (66)
Outdoor Unit OperatingTemperature Range
Cooling Air Temp (Maximum / Minimum)* °F 115 / 14
Cooling Thermal Lock-out / Re-start Temperatures** °F -7 / -4
Heating Air Temp (Maximum / Minimum) °F 75 / 12
Heating Thermal Lock-out / Re-start Temperatures** °F -7 / -4
RefrigerantType R410A
Charge Lbs, oz 3, 16
Piping
Gas Pipe Size O.D. (Flared) In. (mm) 1/2 (12.7)
Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35)
Maximum Piping Length Ft. (m) 100 (30)
Maximum Height Difference Ft. (m) 50 (15)
Maximum Number of Bends 10
Notes
AHRI Rated Conditions(Rated data isdetermined at a fixedcompressor speed)
1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB
*Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
SPECIFICATIONS: SEZ-KD18NA4 & SUZ-KA18NA
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Filter Box with MERV 8 Filters □ FBL 1-3
Wireless Signal Receiver □ PAR-SA9CA-E
Wireless Signal Receiver □ PAR-FA32MA-W
Wireless Signal Receiver □ PAR-FA32MA-E
Wireless Remote Controller □ PAR-FL32MA-E
Backlit, Wall-mounted, Wireless Controller □ MHK1
Portable Central Controller □ MCCH1
Wired MA Controller □ PAR-33MAA
Simple MA Controller □ PAC-YT53CRAU
Touch MA Controller □ PAR-CT01MAU-SB
Wired Remote Sensor □ PAC-SE41TS-E
Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1
Outside Air Sensor for MHK1 □ MOS1
Flush Mount Remote Temperature Sensor □ PAC-USSEN001-FM-1
System Control Interface □ MAC-333IF-E
Wireless Interface □ PAC-USWHS002-WF-1
Thermostat Interface □ PAC-US444CN-1
kumo station® □ PAC-WHS01HC-E
USNAP Interface □ PAC-WHS01UP-E
IT Extender □ PAC-WHS01IE-E
BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1
External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3
Wire for Remote on/off with CN32 connector □ PAC-715AD
Connector and wire for Operation status/error using CN51 □ PAC-725AD
Connector cable for remote display □ PAC-SA88HA-EP
Connector for CN32 (remote on/off) □ PAC-SE55RA-E
Remote Operation Adapter1 □ PAC-SF40RM-E
Bottom Return Plate (Converts low-profile ducted indoor unit from rear return to bottom return) □ BRP-3
External Drain Pump □ PAC-KE07DM-E
Blue Diamond Sensor Extension Cable — 15 Ft. □ C13-103
Blue Diamond Alarm Extension Cable — 6.5 Ft. □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps □ C21-014
Blue Diamond Rubber Foot Pads □ F10-010
Mini Condensate Pump — 230 volt application □ SI30-230
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V
Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] □ X87-721 - 208/230V
Drain Pan Level Sensor □ DPLS2
(30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303
(30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W1 Unable to use with wireless remote controller
ACCESSORIES: SEZ-KD18NA4
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Air Outlet Guide □ MAC-886SG-E
Optional Defrost Heater □ MAC-641BH-U
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P
Condensing Unit Mounting Pad 16" x 36" x 3" □ ULTRILITE1
Outdoor Unit Stand — 12" High □ QSMS1201M
Outdoor Unit Stand — 18" High □ QSMS1801M
Outdoor Unit Stand — 24" High □ QSMS2401M
Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1
Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel □ QSWBSS
15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-15
30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-30
50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-50
65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-65
100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-100
ACCESSORIES: SUZ-KA18NA
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
(46-7/8)1190
(39)990
(31-1/8)790
N
(48-25/32)1239
(40-29/32)1039
(33-1/16)839
M
Drain pipe(O.D.ø32(1-1/4))
Terminal block (Remote controller transmission line)
Terminal block (Indoor/outdoor connecting line)
2 Refrigerant pipingflare connection (liquid)
ø12.7(1/2)
mm(in.)
(35-7/16)
(27-9/16)
(19-11/16)
(41-3/4)
(33-7/8)
(26)
(47-1/4)
(39-3/8)
(31-1/2)
(39-3/8)
(31-1/2)
(23-5/8)
(41-3/4)
(33-7/8)
(26)
(47-3/16)
(39-5/16)
(31-7/16)
(45-3/8)
(37-1/2)
(29-5/8)
(43-5/16)
(35-7/16)
(27-9/16)700
Drain pipe(O.D.ø32(1-1/4))(Emergency draining)
ø6.35(1/4)
ø9.52(3/8)
SEZ-KD15NA4
900 952 998 8609
800 1000 8607
70020
24
16
L
900
500
K
9
5
J
1060
660
H800600
7660798752
Knockout hole ø27(1-3/32) (Remote controller transmission line)
Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line)
G
1200
F
1000
E
11
D
1060
C
1100
B
1152
SEZ-KD09NA4
SEZ-KD12NA4
SEZ-KD18NA4
Model A
1198
Gas pipe Liquid pipe
L-ø2.9(1/8)
2×2-ø2.9(1/8)
2×E-ø2.9(1/8)
Control box
Air filter
Suspension bolt hole4-14×30(9/16×1-3/16) Slot
Refrigerant pipingflare connection (gas)
1
1 2
Drain pipe(O.D.ø32(1-1/4))(Spontaneous draining)
Airinlet
Airoutlet
N
M
175±5(6-29/32±7/32)
Less than 300
Le
ss t
ha
n 5
50
(11-13/16)
(21-2
1/3
2)
Mo
re t
ha
n 2
0
Mo
re t
ha
n 1
0
57(2
-1/4
)
57(2
-1/4
)
(1-31/32 ~ 5-29/32)
(30-1
9/32)
(17-23/32)
(11-1
3/16)
(17-2
3/32)
More than 300
(13/1
6)(1
3/3
2)
(3-9
/16)
(5-2
9/3
2)
(2-25/32)(4-19/32)
70
10(13/32)
(3-1
5/1
6)
(1-15/16) (24-5/8)
450
37(1-15/32)
20
0(7
-7/8
)
H
157.5(6-7/32)20(13/16)
100(3-15/16)
37(1-15/32)
12(1/2)
12(1
/2)
88(3
-15
/32
)
10
0(3
-15
/16
)XJ=
K
10
0(3
-15
/16
)
88(3
-15
/32
)
777
50(1-31/32)
50 ~ 150
50(1-31/32)G
450
10(13/32)
49
25(1
)
17
0(6
-23
/32
)
10
2(4
-1/3
2)
116
10
02
5(1
)
23(29/32)
C
B (
Su
sp
en
sio
n b
olt p
itch
)2
3(2
9/3
2)
A9
0
D (
Du
ct)
10
0(3
-15
/16
)X(E
-1)=
F
10
0(3
-15
/16
)
15(19/32)
Drain hose (I.D.ø32(1-1/4))<accessory>
(Actual length)
Note2
Access door
Required space for service and maintenance
Access doorCeiling surface
Make the access door at the appointed position properlyfor service maintenance.
Note1. Use M10 screw for the suspension bolt (field supply).
2. Keep the service space for the maintenance at the bottom.
3. This chart indicates for SEZ-KD15NA4 model, which has 3 fans.
SEZ-KD09,12NA4 models have 2 fans.
SEZ-KD18NA4 model has 4 fans.
4. When an inlet duct is used, remove the air filter (supply with the unit), then install the filter (field supply) at suction side.
15
9(6
-9/3
2)
345(13-19/32)
20
(13
/16
)
30
(1-3
/16
)
23
(29
/32
)
270(10-21/32)
20
(13
/16
)
625(Suspension bolt pitch)
700(27-9/16)
677(26-21/32)
15
0(D
uct)
Unit: mm (inch)
(46-7/8)1190
(39)990
(31-1/8)790
N
(48-25/32)1239
(40-29/32)1039
(33-1/16)839
M
Drain pipe(O.D.ø32(1-1/4))
Terminal block (Remote controller transmission line)
Terminal block (Indoor/outdoor connecting line)
2 Refrigerant pipingflare connection (liquid)
ø12.7(1/2)
mm (in.)
(35-7/16)
(27-9/16)
(19-11/16)
(41-3/4)
(33-7/8)
(26)
(47-1/4)
(39-3/8)
(31-1/2)
(39-3/8)
(31-1/2)
(23-5/8)
(41-3/4)
(33-7/8)
(26)
(47-3/16)
(39-5/16)
(31-7/16)
(45-3/8)
(37-1/2)
(29-5/8)
(43-5/16)
(35-7/16)
(27-9/16)700
Drain pipe(O.D.ø32(1-1/4))(Emergency draining)
ø6.35(1/4)
ø9.52(3/8)
15 kBtu/h900 952 998 860
9800 1000 860
7700
20
24
16
L
900
500
K
9
5
J
1060
660
H800600
7660798752
Knockout hole ø27(1-3/32) (Remote controller transmission line)
Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line)
G
1200
F
1000
E
11
D
1060
C
1100
B
1152
09 kBtu/h
12 kBtu/h
18 kBtu/h
Sizes A
1198
Gas pipe Liquid pipe
L-ø2.9(1/8)
2×2-ø2.9(1/8)
2×E-ø2.9(1/8)
Control box
Air filter
Suspension bolt hole4-14×30(9/16×1-3/16) Slot
Refrigerant pipingflare connection (gas)
1
1 2
Drain pipe(O.D.ø32(1-1/4))(Spontaneous draining)
Airinlet
Airoutlet
N
M
175±5(6-29/32±7/32)
Less than 300
Le
ss t
ha
n 5
50
(11-13/16)
(21-2
1/3
2)
Mo
re t
ha
n 2
0
Mo
re t
ha
n 1
0
57(2
-1/4
)
57(2
-1/4
)
(1-31/32 ~ 5-29/32)
(30-1
9/32)
(17-23/32)
(11-1
3/16)
(17-2
3/32)
More than 300
(13/1
6)(1
3/3
2)
(3-9
/16)
(5-2
9/3
2)
(2-25/32)(4-19/32)
70
10(13/32)
(3-1
5/1
6)
(1-15/16) (24-5/8)
450
37(1-15/32)
20
0(7
-7/8
)
H
157.5(6-7/32)20(13/16)
100(3-15/16)
37(1-15/32)
12(1/2)
12(1
/2)
88(3
-15
/32
)
10
0(3
-15
/16
)XJ=
K
10
0(3
-15
/16
)
88(3
-15
/32
)
777
50(1-31/32)
50 ~ 150
50(1-31/32)G
450
10(13/32)
49
25(1
)
17
0(6
-23
/32
)
10
2(4
-1/3
2)
116
10
02
5(1
)
23(29/32)
C
B (
Su
sp
en
sio
n b
olt p
itch
)2
3(2
9/3
2)
A9
0
D (
Du
ct)
10
0(3
-15
/16
)X(E
-1)=
F
10
0(3
-15
/16
)
15(19/32)
Drain hose (I.D.ø32(1-1/4))<accessory>
(Actual length)
Note2
Access door
Required space for service and maintenance
Access doorCeiling surface
Make the access door at the appointed position properlyfor service maintenance.
Note1. Use M10 screw for the suspension bolt (field supply).
2. Keep the service space for the maintenance at the bottom.
3. This chart indicates for size 15 kBtu/h model, which has 3 fans.
Sizes 09,12 kBtu/h models have 2 fans.
Sizes 08 kBtu/h model has 4 fans.
4. When an inlet duct is used, remove the air filter (supply with the unit), then install the filter (field supply) at suction side.
15
9(6
-9/3
2)
345(13-19/32)
20
(13
/16
)
30
(1-3
/16
)
23
(29
/32
)
270(10-21/32)
20
(13
/16
)
625(Suspension bolt pitch)
700(27-9/16)
677(26-21/32)
15
0(D
uct)
Unit: mm (inch)
DIMENSIONS: SEZ-KD18NA4
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA
Liquid pipe :1/4 (flared)Gas pipe :3/8 (flared) (KA09/12)
1/2 (flared) (KA15)
6-23/32
2
5-7/
8
2-23/32
1-3/
4
15-3/4
12 ~
12-
3/4
13-9
/16
11/1
6
1-9/16
7/8
21-5
/8
11-1
/32
13/3
2
31-1/2
19-11/165-15/16
11-29/32
17/3229/32 11-1/4
Air in
handle
Air in
Air out
2- 3/8 13/16 Oval hole
Drain hole 1-5/8
REQUIRED SPACE Basically open 4 in. or more without any obstruction in front and on both sides of the unit.
14 in. or more8 in. or more
4 in. or more
4 in. or more
Open two sides of left, right, or rear side.
20-9/32
14
-3/1
6
Air in11-25/32
2-19/32
Air in
Air out19-11/16
33-1/16
13
2
4-25/32
33
-7/1
6
16
-15
/16
3-3/16
4-3/8 × 13/16 slot
1-1
1/3
2
1-9/16Drain 3 holes (ø1-5/16)
30°
35°
2-9
/16
Liquid:1/4(flared)
Gas :1/2(flared)
3-9
/16
8-11/32
15
-9/1
6
Open as a rule 20 in. or more if the front and both sides are open
4 in. or more/ 8 in. or moreif there are obstaclesto both sides
Open as a rule 20 in. or more if the back,both sides and top are open
REQUIRED SPACE
14 in. or more
4 in. or more
Unit: inch
Unit: inch
FORM# SEZ-KD18NA4 / SUZ-KA18NA - 201902Ver3
1340 Satellite Boulevard, Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com
DIMENSIONS: SUZ-KA18NA
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.