M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration...

39
M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study with Kaonic atoms study with SIDDHARTA SIDDHARTA

Transcript of M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration...

Page 1: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

M. IliescuLaboratori Nazionali di Frascati, Rome, Italy

on behalf of the SIDDHARTA collaborationFrom Phi to Psi Novosibirsk,

2011

Kaonic atoms study with Kaonic atoms study with SIDDHARTASIDDHARTA

Page 2: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

SIDDHARTA collaboration

LNF- INFN, Frascati, Italy

SMI - ÖAW, Vienna, Austria

IFIN – HH, Bucharest, Romania

Politecnico, Milano, Italy

MPE, Garching, Germany

PNSensors, Munich, Germany

RIKEN, Japan

Univ. Tokyo, Japan

Victoria Univ., Canada

SIlicon Drift Detector for Hadronic Atom Research

by Timing Applications

EU Fundings: JRA10 – FP6 - I3HP Network WP9 – LEANNIS – FP7- I3HP2

Page 3: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Hadronic atoms

__

Objects of type (K X), ( X) with X = p, d, 3He, 4He,.. or K Bound electromagnetically, binding well knownStrong interaction modify binding decay of object

in some cases: small perturbation energy shift and width can be related to T-matrix elements at threshold (Deser1 type formulas)

compare to results from low energy scattering experiments2

Low energy phenomena in strong interaction are hardly described in terms of quarks and gluons; instead, effective theories are used (they have some degrees of freedom to accomodate experimental data)

1 Deser relation in some cases not sufficient to compare to high precision experimental data 2 Problems: extrapolation to E=0 and quality of old experimental data

Page 4: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

QCD predictions  

Chiral perturbation theory was successful in describing systems like H, but encountered serius difficulties in KH. Main reason is the presence of the (1405) resonance only 25 MeV below threshold. scattering dataEffective field theory atomic X ray data energy, width of resonances

There are non-perturbative coupled channel techniques which are able to generate the (1405) dynamically as a Kbar N quasibound state and as a resonance in the channel

Page 5: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic hydrogen – Deser formula   __

With a0, a1 standing for the I=0,1 S-wave KN complex scattering lengths in the isospin limit (md = mu), being the reduced mass of the K-p system,and neglecting isospin-breaking corrections, the relation reads:

)(2

1

41222

2

10

123

aaa

aeVfmai

pK

pKpK

… a linear combination of the isospinscattering lengths a0 and a1

to disentangle them, also thekaonic deuterium scattering length is needed

2Meißner,Raha,Rusetsky, 2004

‘‘By using the non-relativistic effective Lagrangian approach a complete expressionfor the isospin-breaking corrections can be obtained; in leading order parameter-free modified Deser-type relations exist and can be used to extract scattering lenghts from kaonic atom data“2

Page 6: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic deuterium   For the determination of the isospin dependent scattering lengths a0 and a1 the hadronic shift and width of kaonic hydrogen and kaonic deuterium are necessary !

Elaborate procedures needed to connect the observables with the underlaying physics parameters.“To summarize, one may expect that the

combinedanalysis of the forthcoming high-precision data fromDEAR/SIDDHARTA collaboration on kaonic hydrogenand deuterium will enable one to perform a stringenttest of the framework used to describe low–energy kaon deuteron scattering, as well as to extract the values of a0 and a1 with a reasonable accuracy. However, in order to do so, much theoretical work related to the systematic calculation of higher-order corrections within the non-relativistic EFT is still to be carried out.” (from: Kaon-nucleon scattering lengths from kaonic deuterium, Meißner, Raha, Rusetsky, 2006, arXiv:nucl-th/0603029)

largerthan leadingterm

Page 7: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Summary of physics framework and motivation

Exotic (kaonic) atoms – probes for strong interaction hadronic shift ε1s and width Γ1s directly observable experimental study of low energy QCD. Testing chiral symmetry breaking in

strangeness systems

Kaonic hydrogen Kp simplest exotic atom with strangeness kaonic hydrogen‘‘puzzle“ solved – but: more precise experimental data

important kaonic deuterium never measured before

Information on (1405) sub-threshold resonance responsible for negative real part of scattering amplitude at threshold important for the search for the controversial ‘‘deeply bound kaonic

states” present / upcoming experiments (KEK,GSI,DAFNE,J-PARC)

Determination of the isospin dependent KN scattering lengths no extrapolation to zero energy

Page 8: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

AIMS OF SIDDHARTA

• Improve the previous measurements of the Kaonic hydrogen shift and width.

• First observation of the Kaonic deuterium K lines.

• Precise measurement of the Kaonic He4 L transition.

• First observation and precise measurement of the Kaonic He3 L transition.

Page 9: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Experimental data are available for:

• K- p cross section for elastic and inelastic processes.

• Branching ratios for K- p absorption at rest.

• πΣ invariant mass distribution below K- p threshold, wich exhibits the Λ(1405) resonance.

• 1s level shift and width of K- p atom determined through Xray measurements. (SIDDHARTA)

Kaon-nucleon interaction at low energies

Page 10: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Scattering data vs X-ray measurementsAnalyises on scattering data have been usually made by using a K-matrix formulation with the assumption that its elements are smooth functions of energy, allowing extrapolation down to threshold and below

Scattering data lead to a negative shift, wich means that strong interaction is repulsive and shifts the EM level to a less bound energy.

Scattering data -> ε<0 Old X-ray measurements -> ε>0“Kaonic Hydrogen puzzle”

Page 11: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic Hydrogen Puzzle

KpX at KEK results [6],

[6] M.Iwasaki et al., Phys. Rev. Lett. 78 (1997) 3067 T.M.Ito et al., Phys. Rev. A58 (1998) 2366.

Solved !!

KeK results

Page 12: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

DEAR results [2002-2005]

eVsyststat

eVsyststat

.)(39.)(111249

.)(6.)(37193

Confirming the results found at KeK.

No deuterium measurements due to the very high background

collision Non collision

(KeK)

Page 13: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Previous X-ray measurements summary

Iwasaki

et

al, 1

997

KpX

-500 5000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3

Constant Scattering LengthK-MatrixPotential ModelCloudy Bag ModelConsituent Quark Model

Iwasaki

et

al, 1

997

KpX

-500 5000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3-500 5000-500 5000

0

200

400

600

800

1000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3

Constant Scattering LengthK-MatrixPotential ModelCloudy Bag ModelConsituent Quark Model

Repulsive type

Attractive

DEARDEAR

Page 14: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Nucleus

n=25

n=2n=1

e-

Auger e-

K -

cascade

Kaonic atom formation

Page 15: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Nucleus

n=25

n=2n=1

Strong interaction

X-RAY

K -

Kaonic atom formation

Page 16: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Why it takes so long?

“A measurement of the energy-level shifts and widths for the atomic levels of kaonic hydrogen (and deuterium) would give

a valuable check on analyses of the NK amplitudes, since the energy of the K p atom lies roughly midway between those for

the two sets of data.” Dalitz 1981

-yield strongly reduced by the Stark mixing(monocromatic pure kaon beam, high density gaseous target)

-large area, fast, high resolution X-ray detectors are required

-X-ray background is huge, either on extracted beams, due to pion contaminationand on colliders, due to cm range placement of the target with respect to theinteraction point, in a region were large EM showers are induced by the particleslost from the beam.

Page 17: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

New X-ray detectors (SDD Silicon Drift Detectors) timing capability trigger for

background suppression excellent energy resolution (140 eV at

6.0 KeV) high efficiency, large solid angle. good performance in accelerator

environment

Scint

SD

Ds

Triple coincidence: SDDX * ScintK * ScintK

SIDDHARTA experimental method

e-

• Goal: measure the shift and broadeningof the X ray transition of light kaonic atoms.• The ground state is affected by the strong interaction of the kaon and the nucleus. • Delivers input for effectivetheories in low energy QCD.

Scint

e+

K-

K+

SD

Ds

X

17

E (2-1) (EM) = 6.480 keV

1s level shifted and broadened

144 cm2

Page 18: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

DADANE UPGRADE, NE UPGRADE, 20082008

Page 19: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

19

Φ production cross section ~ 3000 nb (loss-corrected)Integr. luminosity 2009 ~ 6 pb-1 per day 1) (~ 107 K± )(increased by crabbed waist scheme)Peak luminosity ~ 3 × 1032 cm-2 s-1 = 450 Hz K± 1) we can not use kaons produced duringinjections.

DANE

SIDDHARTA is set up here

electron-positron collider, energy at phi resonancephi produced nearly at rest. (boost: 55 mrad crossing angle → 28 MeV/c)charged kaons from phi decay: Ek = 16 MeVdegrade to < 4MeV to stop in gas target

during DEAR data taking (2002)currents ~ 1200/800 ~ 1 pb-1 per day, peak ~

3×1031 cm-2 s-1

Page 20: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

- Monochomatic Kaon beam from decay at rest => facilitates stopping the kaons in a small volume => allows to produce the exotic atoms before kaon decay and enhace the detection efficiency for rare events

-Minimum beam-related hadronic background ( decays in 49% back-to-back charged and 31% neutral kaons)

-High luminosity

-is polarized, so the kaon flux emitted mostly on transverse plane to machine beam pipe (sine 2 distribution)=> easy to capture a high fraction on a limited solid angle

Why at Why at DAΦNE?DAΦNE?

Page 21: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

DAFNE background

SYNCRONOUS: It’s associated to K production, or decays. It can be considered a hadronic background.

ASYNCRONOUS: It’s dued to final products of electromagnetic cascade produced in the accelerator and to other materials activated by electrons lost from the beam. Moreover it also contains Touschek effect (same bunch particles’ interactions)

The main contribute comes from the asyncronous background, wich can be reduced by shielding, trigger and use of fast detectors: SDD (Silicon Drift Detector)

Page 22: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

1 bar

Target

Low density gas• Hydrogen• Deuterium• Helium4, Helium3

Page 23: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

e-

e+

K-

K+

Page 24: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

SIDDHARTA SETUP

(used forcalibration)

(two scintillators timed by the DAFNE RF)

Page 25: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

---- MESON 2010 , 12/06/2010 , A. Romero

----25

Page 26: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaon trigger

Beam pipe

Page 27: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

---- MESON 2010 , 12/06/2010 , A. Romero

----27

Target(filled with Hydrogen,helium or deuterium)

SDD’s

Page 28: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

---- MESON 2010 , 12/06/2010 , A. Romero

----28

144 SDD’s 1cm x 1cm

Page 29: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Trigger

1 ns

2.8 ns

MIP’s

Kaons

Rejection factor >104

Self trigger

MIP’s

Drift time

Kaons are detected by TOF. Two scintillators in coincidense with the collission.

Page 30: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Resolution at 6.4 KeV (FWHM) ~ 140 eV

Calibration runs

Ti KTi K

Cu KCu K

Every 10 normal runs, a calibration run is done using a X-ray tube which activates the Ti and Cu foils, in order to check the setup stability.

(data with Fe source)

Page 31: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Physics Letters B 681 (2009) 310-314

Kaonic He4. First results

Page 32: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

X ray energy (keV)

Counts

/ 4

0eV

KH

e (

3-

2)

Fit of Kaonic Helium 4. New data

KC

(6

-5)

KH

e (

4-

2)

transition e.m.energy events(3-2) 6.464 1047 ± 37(4-2) 8.722 154 ± 21(5-2) 9.767 91.8 ± 19(6-2) 10.333 82.4 ± 25higher < 11.63 131 ± 41

Ti K

KHe used forgas stop optimization+ physics interest1)

data from setup 2(no Fe55 source)

1) compare KEK E570KHe L lines in liquid He,consistent result,first measurement in gas

KH

e (

5-

2)

KN

(5

-4)

32

KH

e L

hig

h

KC

(5

-4)

KH

e (

6-

2)

KO

(6

-5)

KO

(7

-6)

Shift compatiblewith zero

Page 33: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

X ray energy (keV)

Counts

/ 4

0 e

V

KH

e (

3-

2)

Fit of Kaonic Helium 3

KC

(6

-5)

KH

e (

4-

2)

KC

(5

-4)

transition e.m.energy events(3-2) 6.224 1209 ± 40(4-2) 8.399 220 ± 22(5-2) 9.406 90.0 ± 18(6-2) 9.953 65.8 ± 24higher < 11.4 397 ± 40

Ti K

KHe3(never measured before)

Published inPLB 697(2011)199

KH

e (

5-

2)

33

KH

e L

hig

h

KH

e (

6-

2)

KO

(6

-5)

KN

(5

-4)

KO

(7

-6)

Page 34: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic hydrogen data

Page 35: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic hydrogen and kaonic deuterium

Page 36: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Kaonic hydrogen fit

energy (keV)

from the kaonic hydrogen spectrum the Kd specturm was subtracted to get rid of the kaonic background lines KO, KN. 290 pb-1 KH

For the signal 8 voigtians withgiven gauss resolution and free identicallorentz width are used for (2-1),.. (9-1)The position pattern is fixed by the QED values.The intensities of (2-1),(3-1) and (4-1)are free, those of the higher transitions are coupled according to theoretical expectatuions(cascade calculation, Koike‘s values)

KH (2-1) KH

(3-1)

KH (4-1),..(9-1)

Note: Khigh yield pattern

In the final analysis the backgoundis determined from fitting the KD dataand then include the pattren in the KH fit.

ε1s = -283 ± 36(stat) ± 6(syst) eVΓ1s = 541 ± 89(stat) ± 22(syst) eV

Physics Letters B 27935 (2011)

Page 37: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Iwasaki

et

al, 1

997

KpX

-500 5000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3

Constant Scattering LengthK-MatrixPotential ModelCloudy Bag ModelConsituent Quark Model

Iwasaki

et

al, 1

997

KpX

-500 5000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3-500 5000-500 5000

0

200

400

600

800

1000

0

200

400

600

800

1000

Shift (eV) [

Wid

th (

eV

) [

Davie

s

et

al, 1

979

Izycki

et

al, 1

980

Bir

d

et

al, 1

98

3

Constant Scattering LengthK-MatrixPotential ModelCloudy Bag ModelConsituent Quark Model

X-ray measurements summary

Repulsive type

Attractive

DEARDEAR

SIDDHARTASIDDHARTA

Page 38: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Future plans (SIDDHARTA 2)

• SIDDHARTA upgrade (from 2012) for :• Kaonic deuterium precision measurement• Other kaonic atoms (light and heavy) (Si,Pb …)• Charged kaon mass precision measurement.• Feasibility study for Sigmonium atoms.• Kaonic Helium transitions to the 1s level.

-larger target-better shielding and trigger system-new anticoincidence detectorsoverall further background reduction ~30x

Page 39: M. Iliescu Laboratori Nazionali di Frascati, Rome, Italy on behalf of the SIDDHARTA collaboration From Phi to Psi Novosibirsk, 2011 Kaonic atoms study.

Conclusions

• SIDDHARTA has performed accurate measurements of kaonic atoms.• K-p shift ~ -283 eV, width ~541 eV, best precision to date• SIDDHARTA2 plans solving kaonic atoms campaign (2012).• K-d exploratory measurement, small signal, 2• DAFNE represents an unique opportunity to study in a complete way the kaon-nucleon/nuclei physics at low energy.