LXe cryogenic system at KEK

2
LXe cryogenic system at KEK Xe cylind er Recovery Bottle(3.7 5L) SAES Ge tter Monotor 0.75m 3 Tank Circulation Pump (max:20L/min) P3 P2 P1 m TPC PTC Heat exchanger Liquid volume ~1.5L P4 V13 V14 V15 V10 V12 V3 V4 V11 needl e V8 V9 V6 V5 V7 V1 V2 V21 V22 V20 V17 V16 V18 V19 V23 V24 SV PT4 PT1 PT2 PT3 Tch Heater T1 T2 T3 17 June 2008 Purificat ion

description

LXe cryogenic system at KEK. 17 June 2008. Purification. P 2. PT 2. V7. P 3. Circulation Pump (max:20L/min). PT 3. V9. V6. V5. V8. m. SV. V12. P 1. V13. V1. V2. V23. V11 needle. PT 1. V10. P 4. V14. V3. V4. Heat exchanger. V22. V21. V18. V20. V15. PTC. V16. - PowerPoint PPT Presentation

Transcript of LXe cryogenic system at KEK

Page 1: LXe cryogenic system at KEK

LXe cryogenic system at KEK 

Xe cylinderRecoveryBottle(3.75L)

SAES GetterMonotor

0.75m3

Tank

Circulation Pump(max:20L/min)

P3

P2

P1

m

TPC

PTC

Heatexchanger

Liquid volume ~1.5L

P4

V13

V14

V15

V10

V12

V3 V4

V11needle

V8

V9 V6 V5

V7

V1 V2

V21 V22

V20

V17

V16

V18

V19

V23

V24

SV

PT4

PT1

PT2

PT3

Tch

Heater

T1

T2

T3

17 June 2008

Purification

Page 2: LXe cryogenic system at KEK

Gas handling panel

0.75m3 Tank

PT Cryocooler

Test chamber

700W compressor

LXe Cryogenic system at KEK