LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247...

100
Installation Materials Division ...the name behind the brands PRODUCT CATALOGUE LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices PROTEUS SWITCHGEAR

Transcript of LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247...

Page 1: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Installation Materials Division...the name behind the brands

PR

OD

UC

TC

ATA

LOG

UE

LV Switchgear

Distribution Boards

Consumer Units

Circuit Protection Devices

PR

OT

EU

S S

WIT

CH

GE

AR

Page 2: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

2

Welcome to......

Proteus Switchgear

Page 3: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Introduction

ProteusIndustrial ProteusConsumer

01952 292 001

[email protected]

www.proteusswitchgear.co.uk

01527 517 117

[email protected]

www.proteusswitchgear.co.uk

With over 30 years manufacturing experience, Proteus Switchgear continues to expand and broaden its portfolio of electrical products and services. From Power Distribution to LV Switchgear, Metalclad Consumer Units to Circuit Protection, our focus is to offer a complete solution for the domestic, commercial, retail and industrial market sectors.

With two manufacturing facilities based in the heart of the UK, we are ideally placed to service over 800 distributors worldwide. Continual investment enables the company to remain in step with our customers’ expectations, maintain quality, develop new products and respond to market and regulatory requirements. The ongoing development of our manufacturing processes ensures Proteus Switchgear continually supply quality products for today's customer.

C E L E B R A T I N G 3 0 Y E A R S O F B R I T I S H M A N U F A C T U R I N G

Y R S

1988 – 2018

FS 667394

Page 4: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

2

Content

LV Switchboards......................................4Custom Built LV Systems..........................5Special MCCB Panelboards.....................6Specials................................................7MC Range MCCB Panelboards................8Moulded Case Circuit Breakers..............20MCX 3-Phase Distribution Boards...........24CBX 3-Phase Distribution Boards...........25XL 3-Phase Distribution Boards.............26BX 3-Phase Distribution Boards.............28ABX 3-Phase Distribution Boards...........32AX Single Phase Distribution Boards......33IP65 Power Distribution Boards............. 34Fuse Gear & Isolators.............................35Changeover Switches............................42Busbar Chambers..................................44ABS Enclosures.....................................46Contactors & Emergency Stops.............47Earth Bars..............................................48MCBs, RCBOs & RCDs...........................49 SPD - Surge Protection...........................52MCB Boards with Surge Protection.........53

400V SwitchgearMetalclad Consumer Units....................58Insulated Consumer Units.....................66Enclosures/Multi-Purpose Units.............70Meter Isolator Products..........................72Switch Fuses/Fire Alarm Switches..........73Three Phase Consumer Units................74MCBs, RCBOs & RCDs...........................49Timers..................................................76Contactors & Isolators...........................77Accessories.........................................78Specials...............................................80Mantel Units...........................................81Technical Information.............................82

230V Switchgear

Page 5: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

3

IndustrialSwitchgearDivision

Proteus are committed to bringing our customers solutions for power distribution and energy efficiency, whilst focusing on the manufacture of switchgear products specifically designed to offer reliability from ‘plant room to plug top’.With many years of experience in Power & Distribution, we can help you make your energy use and distribution systems safer in order to protect your people, assets and business. Our comprehensive array of electrical distribution products, technologies and services, allows architects and facility owners a flexible approach to their electrical distribution needs.With considerable stock within our UK based factory and 800 distributors worldwide, we are ready and able to satisfy all of your power distribution needs.

Page 6: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 2920014

LV SwitchboardsLV

Sw

itchb

oard

s

- Form 2, Form 3 and Form 4 level of segregation. - Multi-function, analogue/digital tariff and non tariff

metering. - Restricted earth fault protection utilising Class X CTs

providing protection of transformer LV windings. - Cableways positioned to left or right hand of

switchgear or with high/low level pre-connected terminals for front access applications.

- All switchgear has the option of 3 or 4 pole switching.

General construction to BSEN 61439-1&2Specifiable options:

- Manual and automatic changeover systems. - Fully integrated automatic PFC including multi-

stage ‘switching’ hand/off/auto selection, automatic control relays, contactors, fuse protection (25KVAr, 50KVAr stages as standard, other sizes available).

- Sealable supply authority CT chambers. - Surge suppression. - Modular design to customer requirements. - Main incomer options up to 2500 amps.

Page 7: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 5

PR

OTE

US

Custom Built LV Systems

Cus

tom

Bui

lt LV

Sys

tem

sWith increasing emphasis on energy conservation, Proteus Switchgear offers the complete range of intrinsic energy management, varying from timeswitch and relay logic to electronic microprocessor control* of lighting, heating and ventilation and fire/security systems.

To meet these changing requirements in retail, commercial and industrial applications, Proteus Switchgear manufactures custom-designed energy management panels, typically incorporating the following options:

- Main incoming isolation/protection up to 800 amps. - 24 hour essential services distribution. - Point of entry/exit key switch controlled services. - Fire alarm interlocking. - Signage control/extended hours manual override. - Emergency lighting test/battery discharge facility.

Energy Management PanelsGeneral construction to BSEN 61439-1&2

- Panels built to specification or in conjunction with our technical departments.

*Microprocessor specification to be confirmed by client and system supplier, i.e. unit free issued to Proteus for inclusion within panel.

Page 8: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 2920016

Custom Built MCCB BoardsS

peci

al M

CC

B P

anel

boar

ds

Additional facilities that can be included in custom built panels:

- Option of lockable doors for all MCCBs and MCB housings.

- Segregated cableways to suit specific cable sizes and types. Width and depth to suit.

- Feeder MCCB busbar section accepts MCCBs rated up to 250 amps as standard. Larger rated outgoing MCCBs can be factory fitted to busbar systems (upto 800A).

- Distribution busbars up to 800 amps. - Standard enclosures to IP3X. - IP65 enclosures are also available. - Options of main incomer as 3 or 4 pole switching. - Options of MCB or multi-function distribution

boards. - Busbar ratings from 200A to 800A.

General construction to BSEN 61439-1&2

- Changeover systems - Sealable Supply Authority Chambers - Tariff and non-tariff kWH metering - Multi-function metering - Surge suppression

Page 9: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 7

PR

OTE

US

Specials

Spe

cial

s

Fitted DevicesMCBs and RCBOs can be fitted and cabled to terminals and contactors / 3 or 5 pin sockets

Surge ArrestorsType 2 surge arrestor cabled in parallel with supply.

Din rail mounted.

Cabling AssistanceDevices can be cabled to panel mounted terminals to aid cabling

Supply Authority C.T. ChamberSupply authority C.T. chamber with C.T. support plates.

Built to specific supply authority requirements

- Custom built assemblies to customer requirements

Page 10: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 2920018

MC Panel Boards Features & Benefits - 250A, 400A and 800A busbar MCCB Panelboards. - Available from 3 to 18 triple pole outgoing ways as

standard. - Factory fitted incoming MCCB/Isolator up to 800A

(3 & 4pole).

Door fitted over outgoing MCCBs as standard using high quality, steel pin hinges. Removable for ease of fitting.

Modern design allows ultimate flexibility with SP & TP MCCBs which can be fitted in any position.

Outgoing MCCBs up to 250A TP and 200A SP.

Fully shrouded neutral terminal system with clear perspex covers.

3-Phase Panelboards

fully compliant to BS EN 61439-1&2

- Outgoing MCCBs can be factory fitted on request. - High fault level rating, 36kA Icc. - Removable end plates for easy glanding and ease

of installation. - Standard board width 900mm allowing easy cabling.

1

2

3

4

5

Main earth termination5

Main earthing termination point onto high conductivity copper plate and robust bonding throughout.

MC

Ran

ge M

CC

B P

anel

boar

ds

Page 11: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 9

PR

OTE

US

MC Panel Boards Features & Benefits - Construction gives type 2 and type 3 group

mounted segregation to BS EN 61439:Pt1 & 2:2011. - Constructed with 1.6mm thick steel with an epoxy

paint finish to RAL7035. - Other paint finishes available upon request.

- Key hole foot fixings for wall mounting. - Lift off door hinges.

2

34

1

MC

Ran

ge M

CC

B P

anel

boar

ds

Page 12: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200110

MC

Ran

ge M

CC

B P

anel

boar

dsMCCB Panelboards - 250A Busbar 36kA Icc

No. of O/G Ways Cat. No. - 3 pole H (mm) W (mm) D (mm)

3 MCP32/I200 (S) 500 900 170

5 MCP52/I200 (S) 700 900 170

7 MCP72/I200 (S) 700 900 170

11 MCP112/I200 (S) 950 900 170

15 MCP152/I200 (S) 1300 900 170

17 MCP172/I200 (S) 1300 900 170

MCP72/I250

MCP32/I200

No. of O/G Ways Cat. No. - 3 pole H (mm) W (mm) D (mm)

3 MCP32/I250 (S) 500 900 170

5 MCP52/I250 (S) 700 900 170

7 MCP72/I250 (S) 700 900 170

11 MCP112/I250 (S) 950 900 170

15 MCP152/I250 (S) 1300 900 170

17 MCP172/I250 (S) 1300 900 170

200A MCCB Incomer or Switch Disconnector Fitted Boards

250A MCCB Incomer or Switch Disconnector Fitted Boards

Outgoing switchgear supplied separately.

(S) - Add suffix ‘S’ for Switch Disconnector Incomer Fitted Boards e.g. MCP32/I200S

No. of O/G Ways Cat. No. - 4 pole H (mm) W (mm) D (mm)

4 MCP42/I200F 1000 900 170

6 MCP62/I200F 1200 900 170

8 MCP82/I200F 1200 900 170

12 MCP122/I200F 1450 900 170

16 MCP162/I200F 1800 900 170

18 MCP182/I200F 1800 900 170

200A MCCB Incomer Fitted Boards

(S) - Add suffix ‘S’ for Switch Disconnector Incomer Fitted Boards e.g. MCP72/I250S

No. of O/G Ways Cat. No. - 4 pole H (mm) W (mm) D (mm)

4 MCP42/I250F 1000 900 170

6 MCP62/I250F 1200 900 170

8 MCP82/I250F 1200 900 170

12 MCP122/I250F 1450 900 170

16 MCP162/I250F 1800 900 170

18 MCP182/I250F 1800 900 170

250A MCCB Incomer Fitted Boards

MCP42/I200F

MCP62/I250F

Outgoing MCCB’s upto 250A TP and 200A SP.

- Available 3 to 18 triple pole outgoing ways. - Factory fitted incoming MCCB/isolator up to 250A

3/4 pole. - These boards utilise the busbar ability to accept

250A MCCBs by using one way as the incoming position when a 3 pole incomer is acceptable.

- Reduced height where space is at a premium. - Any rating of MCCB up to 250A can be used as the

incomer. - The incoming device is fitted at the top right as

standard to allow cable spreading room, this can be moved to any position.

Page 13: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 11

PR

OTE

US

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPEB32L MCPEB32R 500 200 170

MCPEB52L MCPEB52R 700 200 170

MCPEB72L MCPEB72R 700 200 170

MCPEB112L MCPEB112R 950 200 170

MCPEB152L MCPEB152R 1300 200 170

MCPEB172L MCPEB172R 1300 200 170

MCPEB42FL* MCPEB42FR* 1000 200 170

MCPEB62FL* MCPEB62FR* 1200 200 170

MCPEB82FL* MCPEB82FR* 1200 200 170

MCPEB122FL* MCPEB122FR* 1450 200 170

MCPEB162FL* MCPEB162FR* 1800 200 170

MCPEB182FL* MCPEB182FR* 1800 200 170

MCPEB32L

Side Extension Box - 3 & 4 Pole Incomer

No. of Meter Positions

Cat. No.(Left side)

Cat. No.(Right side)

H (mm) W (mm) D (mm)

2 MCPMB32L MCPMB32R 500 400 170

3 MCPMB52L MCPMB52R 700 400 170

4 MCPMB72L MCPMB72R 700 400 170

6 MCPMB112L MCPMB112R 950 400 170

8 MCPMB152L MCPMB152R 1300 400 170

9 MCPMB172L MCPMB172R 1300 400 170

2 MCPMB42FL* MCPMB42FR* 1000 400 170

3 MCPMB62FL* MCPMB62FR* 1200 400 170

4 MCPMB82FL* MCPMB82FR* 1200 400 170

6 MCPMB122FL* MCPMB122FR* 1450 400 170

8 MCPMB162FL* MCPMB162FR* 1800 400 170

9 MCPMB182FL* MCPMB182FR* 1800 400 170

Side Meter Extension Box - 3 & 4 Pole Incomer

MCPMB52R

Cat. No. H (mm) W (mm) D (mm)

MCPBEB200 200 900 170

MCPBEB300 300 900 170

Bottom Extension Box

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPCB22L MCPCB22R 200 200 170

MCPCB32L MCPCB32R 300 200 170

MCPCB24L MCPCB24R 200 400 170

MCPCB34L MCPCB34R 300 400 170

Corner Extension Box

MCPCB34L MC

Ran

ge M

CC

B P

anel

boar

ds

* - To suit four pole boards.

* - To suit four pole boards.

MCPBEB200

MCCB Panelboards - 250A Busbar 36kA Icc - Range of side extension boxes, side meter boxes,

bottom extension boxes and corner boxes to suit 250A range of MC panels.

- Bottom extension boxes are available in 200 or 300 mm height as standard.

- Side extension and meter boxes are available in left/

right hand and 3/4pole versions sized to suit all. 250A range MC panels

- Corner boxes available when using side and bottom boxes to give a clean look.

- Meters, SPD and EFR for meter boxes available on pages 12 and 13.

Can also be fitted to top of panel if required.

Page 14: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200112

MCCB Panelboards - 400A Busbar 36kA Icc

MCP124/I400

MCP44/I315

MCP44/I400

Outgoing switchgear supplied separately.

MC

Ran

ge M

CC

B P

anel

boar

ds

MCP84/I400S

315A MCCB Incomer Fitted BoardsNo. of O/G Ways

Cat. No. 3 pole

Cat. No. 4 pole

H (mm) W (mm) D (mm)

4 MCP44/I315 MCP44/I315F 1300 900 170

6 MCP64/I315 MCP64/I315F 1500 900 170

8 MCP84/I315 MCP84/I315F 1500 900 170

12 MCP124/I315 MCP124/I315F 1750 900 170

16 MCP164/I315 MCP164/I315F 2100 900 170

18 MCP184/I315 MCP184/I315F 2100 900 170

(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP84/I400S. Triple pole only

400A MCCB Incomer or Switch Disconnector Fitted BoardsNo. of O/G Ways

Cat. No. 3 pole

Cat. No. 4 pole

H (mm) W (mm) D (mm)

4 MCP44/I400 (S) MCP44/I400F 1300 900 170

6 MCP64/I400 (S) MCP64/I400F 1500 900 170

8 MCP84/I400 (S) MCP84/I400F 1500 900 170

12 MCP124/I400 (S) MCP124/I400F 1750 900 170

16 MCP164/I400 (S) MCP164/I400F 2100 900 170

18 MCP184/I400 (S) MCP184/I400F 2100 900 170

Outgoing MCCB’s upto 250A TP and 200A SP.

- Available 4 to 18 triple pole outgoing ways. - Factory fitted incoming MCCB/isolator up to 400A

3/4 pole. - Ample cabling space for incoming cables. - Space next to incomer for metering, earth leakage

protection and surge protection to monitor and protect whole board.

Page 15: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 13

PR

OTE

US

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPEB44L MCPEB44R 1300 200 170

MCPEB64L MCPEB64R 1500 200 170

MCPEB84L MCPEB84R 1500 200 170

MCPEB124L MCPEB124R 1750 200 170

MCPEB164L MCPEB164R 2100 200 170

MCPEB184L MCPEB184R 2100 200 170

MCPEB64L

Side Extension Box

Side Meter Extension Box

MCPMB124L

Cat. No. H (mm) W (mm) D (mm)

MCPBEB200 200 900 170

MCPBEB300 300 900 170

Bottom Extension Box

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPCB22L MCPCB22R 200 200 170

MCPCB32L MCPCB32R 300 200 170

MCPCB24L MCPCB24R 200 400 170

MCPCB34L MCPCB34R 300 400 170

Corner Extension Box

MCPCB34L

No. of Meter Positions

Cat. No.(Left side)

Cat. No.(Right side)

H (mm) W (mm) D (mm)

2 MCPMB44L MCPMB44R 1300 400 170

3 MCPMB64L MCPMB64R 1500 400 170

4 MCPMB84L MCPMB84R 1500 400 170

6 MCPMB124L MCPMB124R 1750 400 170

8 MCPMB164L MCPMB164R 2100 400 170

9 MCPMB184L MCPMB184R 2100 400 170

MC

Ran

ge M

CC

B P

anel

boar

dsMCPBEB200

MCCB Panelboards - 400A Busbar 36kA Icc - Range of side extension boxes, side metering

boxes, bottom extension boxes and corner boxes to suit 400A range of MC panels.

- Bottom extension boxes are available in 200 or 300 mm heights as standard.

- Side extension and meter extension boxes are

available in left/right hand versions sized to suit all 400A range MC panels.

- Corner boxes available when using side and bottom extension boxes to give a clean look.

- Meters, SPD, EFR for meter boxes available on pages 12 and 13.

Can also be fitted to the top of the panel if required.

Page 16: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200114

MCCB Panelboards - 800A Busbar 36kA IccM

C R

ange

MC

CB

Pan

elbo

ards

Outgoing switchgear supplied separately.

MCP48/I500

500A MCCB Incomer Fitted BoardsNo. of O/G Ways

Cat. No. 3 pole

Cat. No. 4 pole

H (mm) W (mm) D (mm)

4 MCP48/I500 MCP48/I500F 1450 900 170

6 MCP68/I500 MCP68/I500F 1650 900 170

8 MCP88/I500 MCP88/I500F 1650 900 170

12 MCP128/I500 MCP128/I500F 1900 900 170

16 MCP168/I500 MCP168/I500F 2250 900 170

18 MCP188/I500 MCP188/I500F 2250 900 170

(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP88/I630S. Triple pole only

630A MCCB Incomer or Switch Disconnector Fitted BoardsNo. of O/G Ways

Cat. No. 3 pole

Cat. No. 4 pole

H (mm) W (mm) D (mm)

4 MCP48/I630 (S) MCP48/I630F 1450 900 170

6 MCP68/I630 (S) MCP68/I630F 1650 900 170

8 MCP88/I630 (S) MCP88/I630F 1650 900 170

12 MCP128/I630 (S) MCP128/I630F 1900 900 170

16 MCP168/I630 (S) MCP168/I630F 2250 900 170

18 MCP188/I630 (S) MCP188/I630F 2250 900 170

(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP88/I800S. Triple pole only

800A MCCB Incomer or Switch Disconnector Fitted BoardsNo. of O/G Ways

Cat. No. 3 pole

Cat. No. 4 pole

H (mm) W (mm) D (mm)

4 MCP48/I800 (S) MCP48/I800F 1450 900 170

6 MCP68/I800 (S) MCP68/I800F 1650 900 170

8 MCP88/I800 (S) MCP88/I800F 1650 900 170

12 MCP128/I800 (S) MCP128/I800F 1900 900 170

16 MCP168/I800 (S) MCP168/I800F 2250 900 170

18 MCP188/I800 (S) MCP188/I800F 2250 900 170

MCP48/I630S

MCP128/I800F

Outgoing MCCB’s upto 250A TP and 200A SP.

- Available 4 to 18 triple pole outgoing ways. - Factory fitted incoming MCCB/isolator up to 800A

3/4 pole. - Ample cabling space for incoming cables. - Space next to incomer for metering, earth leakage

protection and surge protection to monitor and protect whole board.

Page 17: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 15

PR

OTE

US

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPEB48L MCPEB48R 1450 200 170

MCPEB68L MCPEB68R 1650 200 170

MCPEB88L MCPEB88R 1650 200 170

MCPEB128L MCPEB128R 1900 200 170

MCPEB168L MCPEB168R 2250 200 170

MCPEB188L MCPEB188R 2250 200 170

Side Extension Box

Side Meter Extension Box

MCPMB128L

No. of Meter Positions

Cat. No.(Left side)

Cat. No.(Right side)

H (mm) W (mm) D (mm)

2 MCPMB48L MCPMB48R 1450 400 170

3 MCPMB68L MCPMB68R 1650 400 170

4 MCPMB88L MCPMB88R 1650 400 170

6 MCPMB128L MCPMB128R 1900 400 170

8 MCPMB168L MCPMB168R 2250 400 170

9 MCPMB188L MCPMB188R 2250 400 170

MC

Ran

ge M

CC

B P

anel

boar

ds

Bottom Extension Box

Cat. No. (Left side) Cat. No. (Right side) H (mm) W (mm) D (mm)

MCPCB22L MCPCB22R 200 200 170

MCPCB32L MCPCB32R 300 200 170

MCPCB24L MCPCB24R 200 400 170

MCPCB34L MCPCB34R 300 400 170

Corner Extension Box

Cat. No. H (mm) W (mm) D (mm)

MCPBEB200 200 900 170

MCPBEB300 300 900 170

MCPCB34L

MCPBEB200

MCCB Panelboards - 800A Busbar 36kA Icc

MCPEB68L

- Range of side extension boxes, side metering boxes, bottom extension boxes and corner boxes to suit 800A range of MC panels.

- Bottom extension boxes are available in 200 or 300 mm heights as standard.

- Side extension and meter extension boxes are

available in left/right hand versions sized to suit all 800A range MC panels.

- Corner boxes available when using side and bottom extension boxes to give a clean look.

- Meters, SPD, EFR for meter boxes available on Pages 12 and 13.

Can also be fitted to the top of the panel if required.

Page 18: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200116

Amperage Cat. No. (3 Ph) Cat. No. (1 Ph)

63A MCPMFM063T MCPMFM063S

100A MCPMFM100T MCPMFM100S

125A MCPMFM125T MCPMFM125S

160A MCPMFM160T MCPMFM160S

200A MCPMFM200T MCPMFM200S

250A MCPMFM250T -

Non-Tariff Multifunction Multimeters (1 & 3 Phase)

Fitted adjacent to main incomer to monitor total panelboard power usage.No meter extension box required.

Amperage Cat. No. (3 Ph) Cat. No. (1 Ph)

63A MCPMFM063TMID MCPMFM063SMID

100A MCPMFM100TMID MCPMFM100SMID

125A MCPMFM125TMID MCPMFM125SMID

160A MCPMFM160TMID MCPMFM160SMID

200A MCPMFM200TMID MCPMFM200SMID

250A MCPMFM250TMID -

MID/Tariff Multimeters (1 & 3 Phase)

To be fitted adjacent to main incomer to monitor total panelboard power usage. No meter extension box required.

MC

Ran

ge M

CC

B P

anel

boar

ds

MCPMFM063TMeter box supplied separately.

To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400).

Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 100A TP MCCBs (MC100T) and 5 x

Digital multimeters (MCPMFM100T).

Amperage Cat. No. (3 Ph)

315A MCPMFM315T

400A MCPMFM400T

500A MCPMFM500T

630A MCPMFM630T

800A MCPMFM800T

To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible

meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 125A TP MCCBs (MC125T) and 5 x kWH meters

(MCPMFM125TMID).

Amperage Cat. No. (3 Ph)

315A MCPMFM315TMID

400A MCPMFM400TMID

500A MCPMFM500TMID

630A MCPMFM630TMID

800A MCPMFM800TMID

MCPMFM063TMID

Metering - Tariff and non tariff multifunction meters. - Fitting into side meter boxes for outgoing devices or

250A incomers. - Fitted next to incomer on 400A and 800A panels.

Page 19: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 17

PR

OTE

US

Amperage Cat. No.

100A MCPEL100

125A MCPEL125

160A MCPEL160

200A MCPEL200

250A MCPEL250

Earth Leakage Units

To be fitted in meter extension boxes to monitor outgoing / incoming circuits earth leakage up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible

meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 100A TP MCCBs (MC100T) and 5 x Earth Leakage Units (MCPEL100).

- It is intended that the earth leakage units are under the supervision of instructed or skilled persons as defined by regulation 531.2.6 (ii) of the 17th Edition Wiring Regulations.

MC

Ran

ge M

CC

B P

anel

boar

ds

Accessories

Fitted adjacent to main incomer to monitor total panelboard earth leakage. No meter extension box required.

Amperage Cat. No.

400A MCPEL400

630A MCPEL630

MCPEL100

- Earth leakage relay has adjustable trip current and time settings.

- The MCCB is tripped via its integral shunt trip coil. - The full breaking capacity of the MCCB is retained.

Amperage Cat. No. Earthing

≤315A MCPT12/TNS TNS/TNC-S

>315A MCPT12/TNSIF TNS/TNC-S

≤315A MCPT12/TT TT

>315A MCPT12/TTIF TT

>125A MCPT2/TNSIF TNS/TNC-S

>125A MCPT2/TTIF TT

Surge Arrestors - 3 Phase + N (4 Pole)

To be fitted adjacent to main incoming device for boards rated with incomer from 315A - 800A.For 200A - 250A incomer boards, a bottom extension box must be used, e.g. MCPBEB200 if unfused or MCPBEB300 if fused. - TYPE 1: Protection against the effects of lightning. - TYPE 2: Protection against the effects of man made surges on the mains supply system.

Description Cat. No. Voltage Device

Shunt trip for MCCB up to 250A MCST3P250* 220V 3 + 4 pole

Shunt trip for MCCB 315A-630A MCST3P630 220V 3 pole

Shunt trip for MCCB up to 800A MCST3P800 220V 3 pole

Shunt trip for MCCB up to 100A MCST4P100 220V 4 pole

Shunt trip for MCCB 315A-400A MCST4P400** 220V 4 pole

Shunt trip for MCCB 500A-630A MCST4P630 220V 4 pole

Shunt trip for MCCB up to 800A MCST4P800 220V 4 pole

Shunt Trip Units

MCST4P400

* - For MC250TLF use S/T MCST3P630. ** - For MC250FLF use MCST4P400 MCA3P250 - Auxilary contact for MC016T to MC250T. Wire in series with shunt trip MCST3P250.

Page 20: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200118

Enclosures To Suit Individual MCCBs (3 & 4 Pole)

MCENC1

16A - 100A MCENC1F* 400 300 170

125A - 200A MCENC2F* 700 300 170

250A - 630A MCENC6F* 950 400 170

800A MCENC8F* 1300 500 300* - Four pole option.

3 pole units will accept 1 x SP or 1 x TP MCCB. 4 pole units will accept 1 x 4P MCCB only. When fitting a SP MCCB, 2 blanking modules (MCCBM1) will also need to be installed.

250A MCCB must be large frame size MCCB (MC250TLF, MC250FLF).

Amperage Cat. No. H (mm) W (mm) D (mm)

16A - 100A MCENC1 400 300 170

125A - 200A MCENC2 700 300 170

250A - 630A MCENC6 950 400 170

800A MCENC8 1300 500 300

MC

Ran

ge M

CC

B P

anel

boar

ds

Amperage Cat. No. 3 Pole + N Cat. No. 4 Pole H (mm) W (mm) D (mm)

100A MCEL100T MCEL100F 700 300 170

125A MCEL125T MCEL125F 700 300 170

160A MCEL160T MCEL160F 700 300 170

200A MCEL200T MCEL200F 700 300 170

250A MCEL250T MCEL250F 950 400 170

315A MCEL315T MCEL315F 950 400 170

400A MCEL400T MCEL400F 950 400 170

500A MCEL500T MCEL500F 950 400 170

630A MCEL630T MCEL630F 950 400 170

Stand Alone Earth Leakage Units

CT internal diameters of 70mm from 100A to 200A and 120mm for current ratings from 250A to 630A.

MCEL200T

Amperage Cat. No. 3 Pole Cat. No. 4 Pole H (mm) W (mm) D (mm)

63A enclosed MCCB MCE063T MCE063F 400 300 170

80A enclosed MCCB MCE080T MCE080F 400 300 170

100A enclosed MCCB MCE100T MCE100F 400 300 170

125A enclosed MCCB MCE125T MCE125F 700 300 170

160A enclosed MCCB MCE160T MCE160F 700 300 170

200A enclosed MCCB MCE200T MCE200F 700 300 170

250A enclosed MCCB MCE250T MCE250F 950 400 170

315A enclosed MCCB MCE315T MCE315F 950 400 170

400A enclosed MCCB MCE400T MCE400F 950 400 170

500A enclosed MCCB MCE500T MCE500F 950 400 170

630A enclosed MCCB MCE630T MCE630F 950 400 170

800A enclosed MCCB MCE800T MCE800F 1300 500 300

IP3X Enclosed MCCBs

MCE100T

MCCB Enclosures, Pre Assembled Units - It is intended that the earth leakage units are under

the supervision of instructed or skilled persons as defined by regulation 531.2.6 (ii) of the 17th Edition Wiring Regulations.

- Earth leakage relay has adjustable trip current and time settings.

- The MCCB is tripped via its integral shunt trip coil. - The full breaking capacity of the MCCB is retained.

Page 21: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 19

PR

OTE

US

Description Cat. No.

Padlocking device MCPD

SP MCCB blank MCCBM1

Incomer door MCPID

120mm2 lug connection kit for MC016T-MC250T MCLK120

150mm2 lug connection kit for MC016T-MC250T MCLK150

185mm2 lug connection kit for MC016T-MC250T MCLK185

MC063T-MC250T long terminal shield MCLTS

M8 nut insert and bolt for MC016T-MC250T MCNUTM8

900mm200mm 400mm

800m

m30

0mm

700m

m

MCPBEB300 MCPCB34RMCPCB32L

MCPEB64L MCPMB64R

MC400T

MCPT12/TNS1F

MCPEL400

Core Bal. CT

MCP64/I400

E

N

E

N

MCPMFM400T

MC250T

900mm200mm 400mm

700m

m20

0mm

MCPBEB200 MCPCB24RMCPCB22L

MCPEB52L MCPMB52R

MCP52/I250

E E

N N

Additional Accessories

MCCBM1

250A Busbar System

400A and 800A Busbar Systems

General Arrangements

MC

Ran

ge M

CC

B P

anel

boar

ds

*

* - Only up to 400A incomer. 950mm 500A - 800A. Depth 170mm/215mm over door.

MCNUTM8

Page 22: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200120

Mou

lded

Cas

e C

ircui

t Bre

aker

sMCCB Features & Benefits

1

2

3

4

5

- The moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength.

- High quality silver alloy contacts (with elements of

tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life.

- Positive contact indication is by means of the operating lever position.

Moulded Case Circuit Breakers BS EN 60947 1-2

Full technical detail, markings and adjustable parameters clearly identified.

Box clamp terminals for connection of cables upto 120mm2 (upto MC250T).

Fully shrouded terminals.

Phase barriers supplied with lug connected MCCBs.

Mid-trip position of MCCB dolly.

Page 23: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 21

PR

OTE

US

MCCB Features & Benefits

Mou

lded

Cas

e C

ircui

t Bre

aker

s

1

2

3

4

5

Page 24: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200122

MC016T

MC125S

Current Rating (A)

No. of Poles

kA Rating (kA)

Thermal Release

Magnetic Release

Terminal Capacity (mm2)

Cat. No.

16 SP 36 F 500A 120 MC016S

20 SP 36 F 500A 120 MC020S

25 SP 36 F 500A 120 MC025S

32 SP 36 F 500A 120 MC032S

40 SP 36 F 500A 120 MC040S

50 SP 36 F 500A 120 MC050S

63 SP 36 F 500A 120 MC063S

80 SP 36 F 800A 120 MC080S

100 SP 36 F 1000A 120 MC100S

125 SP 36 F 1250A 120 MC125S

160 SP 36 F 1600A 120 MC160S

200 SP 36 F 2000A 120 MC200S

16 TP 36 A (0.8-1xIn) 250A 120 MC016T

20 TP 36 A (0.8-1xIn) 250A 120 MC020T

25 TP 36 A (0.8-1xIn) 250A 120 MC025T

32 TP 36 A (0.8-1xIn) 320A 120 MC032T

40 TP 36 A (0.8-1xIn) 400A 120 MC040T

50 TP 36 A (0.8-1xIn) 500A 120 MC050T

63 TP 36 A (0.8-1xIn) 630A 120 MC063T

80 TP 36 A (0.8-1xIn) 800A 120 MC080T

100 TP 36 A (0.8-1xIn) 1000A 120 MC100T

125 TP 36 A (0.8-1xIn) 1250A 120 MC125T

160 TP 36 A (0.8-1xIn) 1600A 120 MC160T

200 TP 36 A (0.8-1xIn) A (5-10xIn) 120 MC200T

250 TP 36 A (0.8-1xIn) A (5-10xIn) 120 MC250T**

MCCB

Single Pole MCCBs

Triple Pole MCCBs

- The moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength.

- High quality silver alloy contacts (with elements

Mou

lded

Cas

e C

ircui

t Bre

aker

s

** - For panel boards only.

of tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life.

- Positive contact indication is by means of the operating lever position.

MC100TMR

Motor Rated MCCBsMotor Rating KW (approx.)

MCCBAmps

kA Rating (kA)

Thermal Release

Magnetic Release

Terminal Capacity(mm2)

Cat. No.

30 63A 36 0.7-1x In 15xIn 120 MC063TMR

37 80A 36 0.7-1x In 15xIn 120 MC080TMR

51 100A 36 0.7-1x In 15xIn 120 MC100TMR

63 125A 36 0.7-1x In 15xIn 120 MC125TMR

80 160A 36 0.7-1x In 15xIn 120 MC160TMR

90 200A 36 0.7-1x In 10-15xIn 120 MC200TMR

110 250A 36 0.7-1x In 10-15xIn 120 MC250TMR

Page 25: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 23

PR

OTE

US

Mou

lded

Cas

e C

ircui

t Bre

aker

s

MCCB

Current Rating (A)

No. of Poles

kA Rating (kA)

Thermal Release

Magnetic Release

Terminal Capacity (mm2)

Cat. No.

250 TP 36 A (0.8-1xIn) A (5-10xIn) Lugged(M12) MC250TLF

315 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC315T

400 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC400T

500 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC500T

630 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC630T

800 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC800T

1000 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1000T***

1250 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1250T***

1600 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1600T***

Large Frame Triple Pole MCCBs

Large Frame TP MCCBs can not be fitted as an outgoing device. F - Fixed | A - Adjustable | LF - Large frame.MC250TLF must be used when using as an individual cable in, cable out MCCB device.

*** - This MCCB does not fit in MCP panelboards.

MC250TLF

F - Fixed | A - Adjustable| LF - Large frame.

MC800F

Current Rating (A)

No. of Poles

kA Rating (kA)

Thermal Release

Magnetic Release

Terminal Capacity (mm2)

Cat. No.

63 FP 36 A 0-8-1 630 Tunnel-120mm2 MC063FA

100 FP 36 A 0-8-1 1000 Tunnel-120mm2 MC100FA

125 FP 36 A 0-8-1 1250 Tunnel-120mm2 MC125FA

160 FP 36 A 0-8-1 1600 Tunnel-120mm2 MC160FA

200 FP 36 A 0-8-1 5-10X Tunnel-120mm2 MC200FA

250 FP 36 A 0-8-1 5-10X Tunnel-120mm2 MC250FA

250 FP 50 A 0-8-1 5-10X Lugged(M12) MC250FALF

315 FP 50 A 0-8-1 5-10X Lugged(M12) MC315FA

400 FP 50 A 0-8-1 5-10X Lugged(M12) MC400FA

500 FP 50 A 0-8-1 5-10X Lugged(M12) MC500FA

630 FP 50 A 0-8-1 5-10X Lugged(M12) MC630FA

800 FP 36 F 800A A (8-10xIn) Lugged(M12) MC800F

Four Pole MCCBs

Current Rating (A)

No. of Poles

kA* Rating (kA)

Thermal Release

Magnetic Release

Terminal Capacity (mm2)

Cat. No.

200 TP 36 - - Tunnel-120mm2 MC200TNA

250 TP 36 - - Tunnel-120mm2 MC250TNA

400 TP 36 - - Lugged(M12) MC400TNA

630 TP 36 - - Lugged(M12) MC630TNA

800 TP 36 - - Lugged(M12) MC800TNA

Triple Pole Non-Auto MCCBs

F - Fixed | A - Adjustable.MC250FLF must be used when using as an individual cable in, cable out MCCB device.*Non-Auto MCCBs should be protected by a Proteus MC..T/F MCCB of the same rating.

Non-Auto MCCBs cannot be fitted as outgoing devices in MCP panelboards.

MC250TNA

MC250FALF must be used when using as an individual cable in, cable out MCCB device.4 Pole MCCBs cannot be fitted as outgoing devices in MCP panelboards.

Page 26: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200124

MC

X 3

-Pha

se D

istr

ibut

ion

Boa

rds

MCX 3-Phase Distribution Boards

200A MCB/MCCB Distribution Boards

Outgoing switchgear supplied separately.

MCX22/I200

250A MCB/MCCB Distribution Boards

MCX22/I250

Incomer(Factory fitted)

No. of O/G Ways

Cat. No. H (mm) W (mm) D (mm)

200A TP Isolator 2W-63A, 2W-160A MCX22/I200 950 600 170

200A TP Isolator 2W-63A, 4W-160A MCX24/I200 1100 600 170

200A TP Isolator 4W-63A, 2W-160A MCX42/I200 1000 600 170

200A TP Isolator 4W-63A, 4W-160A MCX44/I200 1100 600 170

200A TP Isolator 6W-63A, 2W-160A MCX62/I200 1100 600 170

200A TP Isolator 6W-63A, 4W-160A MCX64/I200 1200 600 170

200A TP Isolator 8W-63A, 2W-160A MCX82/I200 1100 600 170

200A TP Isolator 8W-63A, 4W-160A MCX84/I200 1200 600 170

200A TP Isolator 12W-63A, 2W-160A MCX122/I200 1200 600 170

200A TP Isolator 12W-63A, 4W-160A MCX124/I200 1300 600 170

Incomer(Factory fitted)

No. of O/G Ways

Cat. No. H (mm) W (mm) D (mm)

250A TP Isolator 2W-63A, 2W-160A MCX22/I250 950 600 170

250A TP Isolator 2W-63A, 4W-160A MCX24/I250 1100 600 170

250A TP Isolator 4W-63A, 2W-160A MCX42/I250 1000 600 170

250A TP Isolator 4W-63A, 4W-160A MCX44/I250 1100 600 170

250A TP Isolator 6W-63A, 2W-160A MCX62/I250 1100 600 170

250A TP Isolator 6W-63A, 4W-160A MCX64/I250 1200 600 170

250A TP Isolator 8W-63A, 2W-160A MCX82/I250 1100 600 170

250A TP Isolator 8W-63A, 4W-160A MCX84/I250 1200 600 170

250A TP Isolator 12W-63A, 2W-160A MCX122/I250 1200 600 170

250A TP Isolator 12W-63A, 4W-160A MCX124/I250 1300 600 170

- The MCX range ‘combination board’ brings together the standard TP&N MCB distribution board with typical 17.5mm module MCBs with the opportunity to fit larger amperage MCCBs upto 160A.

- Accepts MCBs up to 63A and RCBOs up to 45A

(17.5mm wide module). - Accepts MCCBs 16A to 160A - Isolator incomer fitted as standard. - Manufactured to BSEN 61439 - Part 1 & 3.

Outgoing switchgear supplied separately.Please refer to page 22 for MCCB circuit protection devices

Please refer to pages 49 & 50 for MCB & RCBO circuit protection devices

Page 27: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 25

PR

OTE

US

CBX 3-Phase Distribution Boards - The CBX range ‘combination board’ brings together

the standard TP&N MCB distribution board with typical 17.5mm module MCBs with the opportunity to fit larger amperage MCBs upto 125A rated.

- Accepts MCBs up to 63A and RCBOs up to 45A

200A MCB Distribution Boards

Outgoing switchgear supplied separately.

CBX22/I200

(17.5mm wide module). - Accepts MCBs 80A to 125A (26.3mm wide module). - Isolator incomer fitted as standard. - Manufactured to BSEN 61439 - Part 1 & 3.

250A MCB Distribution Boards

Outgoing switchgear supplied separately.

CBX24/I250

CB

X 3

-Pha

se D

istr

ibut

ion

Boa

rds

Description Cat. No.

80A SP type C MCB CB080S/C

80A TP type C MCB CB080T/C

100A SP type C MCB CB100S/C

100A TP type C MCB CB100T/C

125A SP type C MCB CB125S/C

125A TP type C MCB CB125T/C

Type C MCB

Description Cat. No. H (mm) W (mm) D (mm)

IP31 steel enclosures to 80-125 SP CBENCSP 385 205 112

IP31 steel enclosures to 80-125 TP CBENCTP 385 205 112

Enclosures

Incomer(Factory fitted)

No. of O/G Ways

Cat. No. H (mm) W (mm) D (mm)

200A TP Isolator 2W-63A, 2W-125A CBX22/I200 950 600 170

200A TP Isolator 2W-63A, 4W-125A CBX24/I200 1100 600 170

200A TP Isolator 4W-63A, 2W-125A CBX42/I200 1000 600 170

200A TP Isolator 4W-63A, 4W-125A CBX44/I200 1100 600 170

200A TP Isolator 6W-63A, 2W-125A CBX62/I200 1100 600 170

200A TP Isolator 6W-63A, 4W-125A CBX64/I200 1200 600 170

200A TP Isolator 8W-63A, 2W-125A CBX82/I200 1100 600 170

200A TP Isolator 8W-63A, 4W-125A CBX84/I200 1200 600 170

200A TP Isolator 12W-63A, 2W-125A CBX122/I200 1200 600 170

200A TP Isolator 12W-63A, 4W-125A CBX124/I200 1300 600 170

Incomer(Factory fitted)

No. of O/G Ways

Cat. No. H (mm) W (mm) D (mm)

250A TP Isolator 2W-63A, 2W-125A CBX22/I250 950 600 170

250A TP Isolator 2W-63A, 4W-125A CBX24/I250 1100 600 170

250A TP Isolator 4W-63A, 2W-125A CBX42/I250 1000 600 170

250A TP Isolator 4W-63A, 4W-125A CBX44/I250 1100 600 170

250A TP Isolator 6W-63A, 2W-125A CBX62/I250 1100 600 170

250A TP Isolator 6W-63A, 4W-125A CBX64/I250 1200 600 170

250A TP Isolator 8W-63A, 2W-125A CBX82/I250 1100 600 170

250A TP Isolator 8W-63A, 4W-125A CBX84/I250 1200 600 170

250A TP Isolator 12W-63A, 2W-125A CBX122/I250 1200 600 170

250A TP Isolator 12W-63A, 4W-125A CBX124/I250 1300 600 170

CB125T/C

CBENCTP Please refer to page 22 for MCCB and pages 49 & 50 for MCB & RCBO circuit protection devices

Page 28: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200126

XL 3-Phase Distribution Boards - 4 to 24 triple pole outgoing ways. - Accepts MCBs from 2A to 63A and RCBOs from 6A

to 45A (17.5mm wide module). - Key lock available for door (XLKL).

XL4S2

Incomer(Factory fitted)

No. of O/G Ways

Cat. No. H (mm) W (mm) D (mm)

125A TP Isolator 4 XL4S125 457 600 132

125A TP Isolator 6 XL6S125 512 600 132

125A TP Isolator 8 XL8S125 567 600 132

125A TP Isolator 12 XL12S125 732 600 132

125A TP Isolator 16 XL16S125 842 600 132

125A TP Isolator 20 XL20S125 942 600 132

125A TP Isolator 24 XL24S125 1217 600 132

200A TP Isolator 4 XL4S2 732 600 132

200A TP Isolator 6 XL6S2 732 600 132

200A TP Isolator 8 XL8S2 732 600 132

200A TP Isolator 12 XL12S2 842 600 132

200A TP Isolator 16 XL16S2 942 600 132

200A TP Isolator 20 XL20S2 1217 600 132

200A TP Isolator 24 XL24S2 1217 600 132

Incomer(Factory fitted)

No. ofTP Way(isolator)

No. ofTP Ways(RCD)

Cat. No.

H (mm) W (mm) D (mm)

100A TP Isolator 4 6 XL46SL 842 600 132

100A TP Isolator 4 8 XL48SL 842 600 132

100A TP Isolator 6 4 XL64SL 842 600 132

100A TP Isolator 6 6 XL66SL 842 600 132

100A TP Isolator 8 4 XL84SL 842 600 132

Three Phase Split Load Distribution Boards

Fitted with a 100A 4pole 30mA RCD as standard.XL84SL

Description Cat. No. W (mm) D (mm)

Key lock for XL range boards XLKL - -

Xl Range Key Lock

XLKL

125A Isolator Incomer Distribution Boards

200A Isolator Incomer Distribution BoardsXL

3-P

hase

Dis

trib

utio

n B

oard

s

XL8S125

- Dual Earth and Neutral terminal bars. - Removable gland plates top & bottom. - Manufactured to BSEN 61439 - Part 3.

Page 29: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 27

PR

OTE

US

Description kWh Meter

Cat. No. H (mm) W (mm) D (mm)

4 way TP&N MCB Board Analogue XL4S1MA 567 600 132

4 way TP&N MCB Board Digital XL4S1MD 567 600 132

6 way TP&N MCB Board Analogue XL6S1MA 732 600 132

6 way TP&N MCB Board Digital XL6S1MD 732 600 132

8 way TP&N MCB Board Analogue XL8S1MA 732 600 132

8 way TP&N MCB Board Digital XL8S1MD 732 600 132

12 way TP&N MCB Board Analogue XL12S1MA 842 600 132

12 way TP&N MCB Board Digital XL12S1MD 842 600 132

16 way TP&N MCB Board Analogue XL16S1MA 942 600 132

16 way TP&N MCB Board Digital XL16S1MD 942 600 132

The XL range of kWh metered boards and split load kWh metered boards, which can be used to meter lighting and power, have over 100% more cabling space than the

Metered Distribution Boards c/w Meter

XL8S1MD

Outgoing switchgear supplied separately.

All above units are supplied complete with a 100A 4pole incoming isolator as standard.

Split Load Metered Distribution Boards

XL68MD

TP meter Ways(lighting)

TP meter Ways(power)

kWh Meter

Cat. No. H (mm) W (mm) D (mm)

4 6 Analogue XL46MA 969 600 132

4 6 Digital XL46MD 969 600 132

6 8 Analogue XL68MA 1079 600 132

6 8 Digital XL68MD 1079 600 132

8 12 Analogue XL812MA 1299 600 132

8 12 Digital XL812MD 1299 600 132

Additional split load configuration available on request.

Split Load Metered Board Incoming Isolator KitsDescription Cat. No. H (mm) W (mm) D (mm)

125A 4 pole isolator incoming kit XLI125 400 600 132

200A 4 pole isolator incoming kit XLI200 400 600 132

Each individual XL distribution board unit with meter fitted must not exceed 100A full load current per phase. Select isolator incoming kit to satisfy the total load current demand.

Meters & Enclosures

KWH2D

Description kWh Meter

Cat. No. H (mm) W (mm) D (mm)

100A DP direct connect meter Analogue KWH2A 90 75 73

100A DP direct connect meter Digital KWH2D 90 75 73

100A 4P direct connect meter Analogue KWH4A 90 125 73

100A 4P direct connect meter Digital KWH4D 90 125 73

100A DP meter enclosure only - KWH2E 383 235 125

100A 4P meter enclosure only - KWH4E 383 235 125 XL

3-P

hase

Dis

trib

utio

n B

oard

s

XL 3-Phase Distribution Boardsstandard equivalent three phase board. kWh meters are factory fitted to monitor the number of ways chosen to suit the application.

Page 30: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200128

BX 3-Phase Distribution Boards - Available in 4, 6, 8, 12, 16, 20 to 24 triple pole

outgoing ways. - Wide selection of factory fitted incoming devices

to choose from to meet the demands of modern installations.

BX12S2

125A Isolator Incomer Distribution Boards

200A Isolator Incomer Distribution Boards

BX8S125

BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD).

BX

3-P

hase

Dis

trib

utio

n B

oard

s - Accepts MCBs from 2A to 63A and RCBOs from 6A to 45A (17.5mm wide module).

- Dual Earth and Neutral terminal bars. - Manufactured to BSEN 61439 parts 1 & 3. - Removable gland plates, top and bottom.

BX8S250

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

250A TP Isolator 8 BX8S250 950 500 170

250A TP Isolator 12 BX12S250 950 500 170

250A TP Isolator 16 BX16S250 1300 500 170

250A TP Isolator 20 BX20S250 1300 500 170

250A TP Isolator 24 BX24S250 1300 500 170

250A Isolator Incomer Distribution Boards

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

125A TP Isolator 4 BX4S125 390 410 110

125A TP Isolator 6 BX6S125 442 410 110

125A TP Isolator 8 BX8S125 495 410 110

125A TP Isolator 12 BX12S125 600 410 110

125A TP Isolator 16 BX16S125 810 410 110

125A TP Isolator 20 BX20S125 1000 410 110

125A TP Isolator 24 BX24S125 1180 410 110

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

200A TP Isolator 4 BX4S2 600 410 110

200A TP Isolator 6 BX6S2 600 410 110

200A TP Isolator 8 BX8S2 700 410 110

200A TP Isolator 12 BX12S2 810 410 110

200A TP Isolator 16 BX16S2 1000 410 110

200A TP Isolator 20 BX20S2 1180 410 110

200A TP Isolator 24 BX24S2 1180 410 110

Page 31: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 29

PR

OTE

US

Outgoing switchgear supplied separately.

BX6P30

BX6Q30

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

63A 4P 30mA RCD 4 BX4P30 495 410 110

63A 4P 30mA RCD 6 BX6P30 600 410 110

63A 4P 30mA RCD 8 BX8P30 600 410 110

63A 4P 30mA RCD 12 BX12P30 700 410 110

63A 4P 30mA RCD 16 BX16P30 810 410 110

63A 4P 30mA RCD 20 BX20P30 1000 410 110

63A 4P 30mA RCD 24 BX24P30 1180 410 110

63A Type A 4 Pole 30mA RCD Incomer Distribution Boards

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

80A 4P 30mA RCD 4 BX4Q30 495 410 110

80A 4P 30mA RCD 6 BX6Q30 600 410 110

80A 4P 30mA RCD 8 BX8Q30 600 410 110

80A 4P 30mA RCD 12 BX12Q30 700 410 110

80A 4P 30mA RCD 16 BX16Q30 810 410 110

80A 4P 30mA RCD 20 BX20Q30 1000 410 110

80A 4P 30mA RCD 24 BX24Q30 1180 410 110

80A Type A 4 Pole 30mA RCD Incomer Distribution Boards

BX

3-P

hase

Dis

trib

utio

n B

oard

s

BX 3-Phase Distribution Boards

BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD).

BX Multi Purpose UnitsCat. No. (Solid door) H (mm) W (mm) D (mm)

BXM14 265 410 110

BXM28 495 410 110

BXM14

Page 32: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200130

BX

3-P

hase

Dis

trib

utio

n B

oard

sBX 3-Phase Distribution Boards

100A Type A 4 Pole 100mA RCD Incomer Distribution Boards

BX6R100

100A Type A 4 Pole 300mA RCD Incomer Distribution Boards

BX6R300

Outgoing switchgear supplied separately.

BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD).

BX4R30

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A 4P 30mA RCD 4 BX4R30 495 410 110

100A 4P 30mA RCD 6 BX6R30 600 410 110

100A 4P 30mA RCD 8 BX8R30 600 410 110

100A 4P 30mA RCD 12 BX12R30 700 410 110

100A 4P 30mA RCD 16 BX16R30 810 410 110

100A 4P 30mA RCD 20 BX20R30 1000 410 110

100A 4P 30mA RCD 24 BX24R30 1180 410 110

100A Type A 4 Pole 30mA RCD Incomer Distribution Boards

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A 4P 100mA RCD 4 BX4R100 495 410 110

100A 4P 100mA RCD 6 BX6R100 600 410 110

100A 4P 100mA RCD 8 BX8R100 600 410 110

100A 4P 100mA RCD 12 BX12R100 700 410 110

100A 4P 100mA RCD 16 BX16R100 810 410 110

100A 4P 100mA RCD 20 BX20R100 1000 410 110

100A 4P 100mA RCD 24 BX24R100 1180 410 110

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A 4P 300mA RCD 4 BX4R300 495 410 110

100A 4P 300mA RCD 6 BX6R300 600 410 110

100A 4P 300mA RCD 8 BX8R300 600 410 110

100A 4P 300mA RCD 12 BX12R300 700 410 110

100A 4P 300mA RCD 16 BX16R300 810 410 110

100A 4P 300mA RCD 20 BX20R300 1000 410 110

100A 4P 300mA RCD 24 BX24R300 1180 410 110

BX AccessoriesDescription Cat. No. (Solid door) H (mm) W (mm) D (mm)

Spreader box BXSB1 265 410 110

Spreader box BXSB2 495 410 110

100/125A Single phase conv kit BXSCK1 - - -

200A Single phase conv kit BXSCK2 - - -

Key lock for door XLKL - - -BXSB2

100A 100mA boards available with Type S RCD on request.

100A 300mA boards available with Type S RCD on request.

Page 33: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Cas

e S

tudy

HALFORDSSpecial Distribution Boards

Halfords were previously purchasing pre-assembled, standard switch boards from an alternative overseas manufacturer, the design and lead

time of which was becoming an issue and Halfords realised they required a more bespoke, future proof solution.

Following contact with ‘Proteus Industrial Switchgear’ of Telford a site visit to an existing store was arranged where further design discussions were held with the installation electricians. The discussions resulted in the design of a distribution panel incorporating multiple mcb boards,

contactors, time switches and emergency lighting test equipment which were all designed to meet their future requirements

An initial trial installation was successfully completed at the new Halfords store in Beckton.

Bruce Birkmyre, Store Development Manager said, “ with Proteus being a UK based manufacturer it was easy to discuss our requirements and

make any changes as the design progressed. The end result was a more cost effective panel board with reduced supply and site installation time.”

Page 34: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200132

3-Phase ABX Board - Horizontal

ABX4S1

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A 4P Isolator 2 ABX2S1 269 326 110

100A 4P Isolator 4 ABX4S1 269 436 110

100A 4P Isolator 6 ABX6S1 269 562 110

100A 4P Isolator 8 ABX8S1 269 673 110

100A 4P Isolator 12 ABX12S1 269 900 110

- Busbars are 80A max with 100A intermittent rating and are one piece construction.

- Cleanline overall hinged door (key operated lockable door optional).

- Accepts RCBOs and MCBs, 17.5mm wide module.

- Isolators can be locked in ON and OFF position (using DL1 locking device).

- Robust IP3X steel construction. - ABX Manufactured to BSEN61439 parts 1 & 3.

Outgoing switchgear ordered separately.

3-Phase ABX Board - Vertical

ABX4S1V

ABX Boards

Incomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A 4P Isolator 2 ABX2S1V 326 269 110

100A 4P Isolator 4 ABX4S1V 436 269 110

100A 4P Isolator 6 ABX6S1V 562 269 110

100A 4P Isolator 8 ABX8S1V 673 269 110

100A 4P Isolator 12 ABX12S1V 900 269 110

AB

X 3

-Pha

se D

istr

ibut

ion

Boa

rds

No. of O/GTP Ways

Cat. No.100A 30mA RCD Incomer

Cat. No.100A 100mA RCD Incomer

Cat. No.100A 300mA RCD Incomer

H (mm) W (mm) D (mm)

2 ABX2R30 ABX2R100 ABX2R300 269 326 110

4 ABX4R30 ABX4R100 ABX4R300 269 436 110

6 ABX6R30 ABX6R100 ABX6R300 269 562 110

8 ABX8R30 ABX8R100 ABX8R300 269 673 110

12 ABX12R30 ABX12R100 ABX12R300 269 900 110

Horizontal ABX Type A RCD Boards

ABX2R30

ABX4R300V

No. of O/GTP Ways

Cat. No.100A 30mA RCD Incomer

Cat. No.100A 100mA RCD Incomer

Cat. No.100A 300mA RCD Incomer

H (mm)

W (mm)

D (mm)

2 ABX2R30V ABX2R100V ABX2R300V 326 269 110

4 ABX4R30V ABX4R100V ABX4R300V 436 269 110

6 ABX6R30V ABX6R100V ABX6R300V 562 269 110

8 ABX8R30V ABX8R100V ABX8R300V 673 269 110

12 ABX12R30V ABX12R100V ABX12R300V 900 269 110

Vertical ABX Type A RCD Boards

Page 35: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 33

PR

OTE

US

AX SP&N Type A Distribution BoardsIncomer(Factory fitted)

No. of O/GSP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A DP Isolator 4 AX4 269 326 110

100A DP Isolator 6 AX6 269 326 110

100A DP Isolator 8 AX8 269 326 110

100A DP Isolator 12 AX12 269 436 110

100A DP Isolator 16 AX16 269 436 110

100A DP Isolator 20 AX20 269 562 110

100A DP Isolator 26 AX26 269 673 110

AX SPN MCB Metered Distribution BoardsIncomer(Factory fitted)

No. of O/GSP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

100A DP Isolator 4 AX4MA 269 326 110

100A DP Isolator 4 AX4MD 269 326 110

100A DP Isolator 8 AX8MA 269 436 110

100A DP Isolator 8 AX8MD 269 436 110

100A DP Isolator 12 AX12MA 269 436 110

100A DP Isolator 12 AX12MD 269 436 110

All the above metered units are supplied complete with 100A 2 pole Isolators as standard and manufactured to BSEN61439-3. Add suffix ‘/CD’ for the clear door option.

AX4

AX12MA

AX Boards

AX

Sin

gle

Pha

se D

istr

ibut

ion

Boa

rds

- Busbars are 80A max with 100A intermittent rating and are one piece construction.

- Cleanline overall hinged door (key operated lockable door optional).

- Accepts RCBOs and MCBs, 17.5mm wide module.

- Isolator can be locked in ON or OFF position (using DL1 locking device).

- Robust IP3X steel construction. - AX Manufactured to BSEN61439 parts 1 & 3.

Page 36: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200134

IP65 Power Distribution Boards

125A TP Isolator - Steel EnclosureIncomer(Factory fitted)

No. of O/GTP ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

125A TP isolator 4 PDU4SS 500 400 200

125A TP isolator 6 PDU6SS 600 400 200

125A TP isolator 8 PDU8SS 600 400 200

125A TP isolator 12 PDU12SS 800 400 200

125A TP isolator 16 PDU16SS 800 400 200

200A TP Isolator - Steel EnclosureIncomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

200A TP isolator 4 PDU4S2S 600 400 200

200A TP isolator 6 PDU6S2S 600 400 200

200A TP isolator 8 PDU8S2S 800 400 200

200A TP isolator 12 PDU12S2S 1100 400 200

200A TP isolator 16 PDU16S2S 1300 400 200

125A TP Isolator - GRP EnclosureIncomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

125A TP isolator 4 PDU4S 500 400 200

125A TP isolator 6 PDU6S 600 500 250

125A TP isolator 8 PDU8S 600 500 250

125A TP isolator 12 PDU12S 800 600 300

125A TP isolator 16 PDU16S 800 600 300

200A TP Isolator - GRP EnclosureIncomer(Factory fitted)

No. of O/GTP Ways

Cat. No.(Solid door)

H (mm) W (mm) D (mm)

200A TP isolator 4 PDU4S2 600 500 250

200A TP isolator 6 PDU6S2 600 500 250

200A TP isolator 8 PDU8S2 800 600 300

IP65

Pow

er D

istr

ibut

ion

Boa

rds

4 pole Type A RCD incomer options available on request factory fitted.Key locks for GRP Power Distribution Boards also available - GRPKL.Key locks for Steel Power Distribution Boards also available - STLKL.

- All boards will accept RCBOs and MCBs 17.5mm wide modules.

- Isolators can be locked in ON and OFF position (using DL1 locking device).

- Manufactured to BSEN61439 parts 1 & 3.

PDU4S

PDU6S2S

PDU4SS

PDU4S2

Page 37: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 35

PR

OTE

US

Current Rating A AC21/AC23

No. of Poles

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

63 3P + N WFS63/IP65SS 500 400 200 70

100 3P + N WFS100/IP65SS 500 400 200 70

125 3P + N WFS125/IP65SS 600 400 200 70

160 3P + N WFS160/IP65SS 600 400 200 70

200 3P + N WFS200/IP65SS 700 500 300 70

WFS100/IP65

WSF63/IP65SS

IP65 Switch Disconnector Fuses

Additional ratings available upon request. Manufactured to BSEN60947.

H

W D1

D2

Fused Switches - Steel Enclosed

Current Rating A AC21/AC23

No. of Poles

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

63 3P + N WFS63/IP65 500 400 200 70

100 3P + N WFS100/IP65 500 400 200 70

125 3P + N WFS125/IP65 600 500 250 70

160 3P + N WFS160/IP65 600 500 250 70

200 3P + N WFS200/IP65 800 600 300 70

Fused Switches - GRP Enclosed

Current Rating A AC21/AC23

No. of Poles

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

20/11 3P + N WSF20/IP65SS 400 300 200 40

32/18 3P + N WSF32/IP65SS 400 300 200 40

63/35 3P + N WSF63/IP65SS 500 400 200 40

100/70 3P + N WSF100/IP65SS 500 400 200 40

Switch Disconnector Fuses - Steel Enclosed

Current Rating A AC21/AC23

No. of Poles

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

20/11 3P + N WSF20/IP65 400 300 200 40

32/18 3P + N WSF32/IP65 400 300 200 40

63/35 3P + N WSF63/IP65 500 400 200 40

100/70 3P + N WSF100/IP65 500 400 200 40

Switch Disconnector Fuses - GRP Enclosed

Fuse

Gea

r &

Isol

ator

s

Page 38: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200136

General DutyCurrent Rating A - AC23

CSA Max mm2

Bolt Size(metric)

Power Rating at 400V (kW)

Proteus BS88 pt2 Fuse fitted

Cat. No. H (mm) W (mm) D1 (mm)

D2 (mm)

63 95* M8 33 PBD U63FS 500 350 185 70

100 95* M8 55 PCD U100FS 500 350 185 70

125 95* M8 59 PDD U125FS 500 350 185 70

160 95* M8 75 PDD U160FS 500 350 185 70

200 150/185** M10 110 PDD U200FS 700 400 255 70

250 150/185** M10 132 PED U250FS 700 400 255 70

315 185** M10 185 PED U315FS 700 400 255 70

400 185/240# M10 220 PED U400FS 900 400 330 70

500 - M12 275 PFF U500FS 1300 500 300 70

630 - M12 300 PFF 630FS 1300 500 347 70

800 - M12 450 PGF 800FS*** 1625 654 600 70

Switch Disconnector FuseFu

se G

ear

& Is

olat

ors

U200FS

H

W D1

D2

- Switch mechanism rated at 65kA when fitted with appropriate BS88 fuses.

- Heavy duty interlocking handle. - Fully rated BS88 fuses fitted.

* - when using 95mm2 cable it is recommended that the UCB1 is fitted.** - when using 185mm2 cable it is recommended that the UCB2 is fitted.# - when using 240mm2 cable it is recommended that the UCB4 is fitted.

*** - Floor standing unit.

- 4 pole configuration available on request. - Built-in cable box suitable for most applications. - Manufactured to BSEN60947 parts 1 & 3.

Page 39: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 37

PR

OTE

US

Switch Disconnector

Fuse

Gea

r &

Isol

ator

s

H

W D1

D2

* - when using 95mm2 cable it is recommended that the UCB1 is fitted.** - when using 185mm2 cable it is recommended that the UCB2 is fitted.# - when using 240mm2 cable it is recommended that the UCB4 is fitted.

General DutyCurrent Rating A - AC23

CSA Max mm2

Bolt Size(metric)

Power Rating at 400V (kW)

Cat. No. H (mm) W (mm) D1 (mm)

D2 (mm)

63 95* M8 33 U63S 500 350 185 70

100 95* M8 55 U100S 500 350 185 70

125 95* M8 59 U125S 500 350 185 70

160 95* M8 75 U160S 500 350 185 70

200 150/185** M10 110 U200S 700 400 255 70

250 150/185** M10 132 U250S 700 400 255 70

315 185** M10 185 U315S 700 400 255 70

400 185/240# M10 220 U400S 900 400 330 70

500 - M12 275 U500S 1300 500 300 70

630 - M12 300 U630S 1300 500 300 70

AccessoriesDescription Cat. No. H (mm) W (mm) D (mm)

Cable spreader box to suit up to U160FS/U160S

UCB1 200 355 185

Cable spreader box to suit U200FS/U200S upto U315FS/U315S

UCB2 200 410 255

Cable spreader box to suit U400FS/U400S UCB4 200 410 330

Fuse barrier for U250FS/S - U400FS/S UFB200 - - -

Fuse barrier for U063FS/S - U160FS/S UFB63 - - -

Handle for UFS/S UFH - - -

Shaft for UFS/S UFS - - -

U200S

UCB2

Page 40: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200138

TS100T

TSF20T

Switch DisconnectorCurrent Rating A AC21A/AC22A

Current Rating A AC23A

Power at 400v (kW) AC23A

Max. Stranded Cable CSA mm2

Cable Termination Type

Cat. No. H (mm) W (mm) D1 (mm)

D2 (mm)

20 20 9 10 Tunnel TS20T 195 235 125 35

32 32 15 10 Tunnel TS32T 195 235 125 35

63 63 30 35 Tunnel TS63T 383 235 125 40

100 100 45 70 Tunnel TS100T 383 235 125 40

125 125 63 70 M8 Lug TS125T 500 350 185 70

160 160 80 70 M8 Lug TS160T 500 350 185 70

200 200 100 70 M8 Lug TS200T 500 350 185 70

Telford Switchgear Range - Epoxy powder coat finish. - Robust, heavy duty steel enclosure. - Folded construction for extra rigidity. - Flush fitting door. - Door removable for ease of installation.

- Fully insulated rotary operating handle. - Padlockable in off position for security. - Screened or finger protected terminals. - Manufactured to BSEN60947 parts 1 & 3.

Switch Disconnector FusesCurrent Rating A AC21A/AC22A

Current Rating A AC23A

Power at 400v (kW)

Max. Stranded Cable CSA mm2

Proteus BS88 pt.2 Fuse

Cable Termination Type

Cat. No.

H (mm)

W (mm)

D1 (mm)

D2 (mm)

20 20 9 25 PNITD Tunnel TSF20T 283 235 125 45

32 32 15 25 PNITD Tunnel TSF32T 283 235 125 45

63 63 30 25 PBAO Tunnel TSF63T 420 300 145 45

100 100 51 70 PCEO M8 Lug TSF100T 420 300 145 45

160 160 80 70 PDD M8 Lug TSF160T 500 350 185 70

H

W D1

D2

Fuse

Gea

r &

Isol

ator

s

Page 41: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 39

PR

OTE

US

Euro Switchgear Range

Fuse

Gea

r &

Isol

ator

s

- Fully insulated high visibility rotary operating handle. - Padlockable in off position for security. - Finger protected cable terminations. - Epoxy powder coat finish. - Robust, heavy duty steel enclosure.

- Folded steel construction for extra rigidity. - Flush fitting door. - Door removable for ease of installation. - Manufactured to BSEN60947 parts 1 & 3.

Switch DisconnectorsCurrent Rating A AC21A/AC22A

Current Rating A AC23A

Power at 400v (kW) AC23A

Max. Stranded Cable CSA mm2

Cable Termination Type

Cat. No.

20 11 6.5 16 Tunnel E20TN

32 28 15 16 Tunnel E32TN

63 63 37 35 Tunnel E63TN

100 100 50 35 Tunnel E100TN

160 80 75 70 Tunnel E160TN

200 125 75 70 Tunnel E200TN

E20TN

Key features - as above plus, Fully rated fuses fitted. Cable Termination Type - Tunnel. TIS and TCP are ‘Bolt in’ fuses to BS88 pt2. Accessory - MN10 is a screw fixed add-on switched 4th pole for 63/100A units

Switch Disconnector FusesCurrent Rating A AC21A/AC22A

No. of Poles

Current Rating A AC23A

Power at 400v (kW) AC23A

Max. Stranded Cable CSA mm2

Proteus Fuse to BS88 pt.2&6/ Spare Fuse Unit

Cat. No.

20 3 P+N 11 5.5 16 PNSD/TDH2 Part [6] EF20TN

20 1 P+N - - 16 PNSD/TDH2 Part [6] EF20S

20 2 P+N - - 16 PNSD/TDH2 Part [6] EF20D

32 3 P+N 18 9 16 PNSD/TDH3 Part [6] EF32TN

32 1 P+N - - 16 PNSD/TDH3 Part [6] EF32S

32 2 P+N - - 16 PNSD/TDH3 Part [6] EF32D

63 3 P+N 63 35 35 TIS/TDH6 Part [2] EF63TN

63 1 P+N - - 35 TIS/TDH6 Part [2] EF63S

63 2 P+N - - 35 TIS/TDH6 Part [2] EF63D

100 3 P+N 100 50 35 TCP/TDH10 Part [2] EF100TN

100 1 P+N - - 35 TCP/TDH10 Part [2] EF100S

100 2 P+N - - 35 TCP/TDH10 Part [2] EF100D

H

W D1

D2

EF20TN

SizesProduct H (mm) W (mm) D1 (mm) D2 (mm)

E20TN, E32TN 195 235 125 35

E63TN, E100TN 383 235 125 35

E160TN, E200TN 420 300 145 45

EF20TN, EF32TN, EF20S, EF32S, EF20D, EF32D

283 235 125 35

EF63TN, EF63S, EF63D 420 300 145 45

EF100S, EF100D, EF100TN 420 350 145 45

Page 42: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200140

Fuse

Gea

r &

Isol

ator

s

M32T

3 Pole IP65 Rotary IsolatorCurrent Rating A AC21A

Power at 400v (kW) AC23A

Power at 400v (kW) AC3

No. of Poles

Max. Cable

Cat. No.

20 6.5 4 3 6 M20T

25 12 11 3 6 M25T

32 15 13 3 6 M32T

63 37 30 3 16 M63T

100 50 37 3 35 M100T

160 55 - 3 70 M160T

200 75 - 3 70 M200T

Madeley Switchgear Range - Manufactured to BSEN 60947 Parts 1 & 3. - IP65 polycarbonate enclosure. - Cable knockouts provided. - Padlockable operating handle for security.

* - Fitted with 2 auxiliary contacts.

4 Pole IP65 Rotary IsolatorCurrent Rating A AC21A

Power at 400v (kW) AC23A

Power at 400v (kW) AC3

No. of Poles

Max. Cable

Cat. No.

20 6.5 4 4 6 M204

25 12 11 4 6 M254

32 15 13 4 6 M324

63 37 30 4 16 M634

100 50 37 4 35 M1004

160 55 - 4 70 M1604

200 75 - 4 70 M2004

6 Pole IP65 Rotary IsolatorCurrent Rating A AC21A

Power at 400v (kW) AC23A

Power at 400v (kW) AC3

No. of Poles

Max. Cable

Cat. No.

20 6.5 4 6 2 x 2.5 M206

32 12 11 6 6 M326

63 37 30 6 35 M636

32 12 11 6* 6 M3262

63 37 30 6* 35 M6362

H

W D1D2

SizesProduct H (mm) W (mm) D1 (mm) D2 (mm)

M20T, M25T, M32T, M204, M254, M324 125 100 70 35

M63T, M634 175 115 80 35

M100T, M1004 285 200 127 45

M160T, M1604 380 283 130 43

M200T, M2004 380 283 130 43

M206 135 80 95 35

M326, M3262 180 100 100 35

M636, M6362 245 160 160 45

M254

- Finger protected cable terminations. - Earth & Neutral terminals fitted. - Customer fitted auxiliary contacts (6 amp rated

1-N/O, 1-N/C) available on 3 pole units.

M206

Page 43: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 41

PR

OTE

US

Sw

itch

Dis

conn

ecto

r Fu

se U

nits

PX

3-P

hase

Dis

trib

utio

n B

oard

s

Cas

e S

tudy

DRAYTON MANOR THEME PARK - THOMAS LANDPRO2000 LV Switchboard

Proteus Switchgear PRO2000 LV switchboard was designed to tap off from an 11kV ring to supply the vast majority of the Thomas Land’s electrical

needs.The timescale for the project was tight from the onset and as quoted by

the contractor only Proteus Switchgear offered to meet the challenge. The goods were specified, quoted, designed and supplied within 8 weeks.

Keeping the progress of the project on schedule and supporting the contractor along the way with respect to technical support and advice were

key to customer satisfaction.Proteus Switchgear were also noted for their excellent co-operation and

team work when it came to accommodating a significant mid-project modification to the switchboard involving the upgrading of an outgoing switch fuse from 100A to 250A. With the assistance of Proteus staff the

work involved in changeover was completed in less than 1 hourThe contractor claims the high profile of the installation and overall

successful completion and handover of the project has also increased the profile of his company and led to further job opportunities for his team with

work on this scale.

Page 44: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200142

H

W D1

D2

Steel Enclosures to IP31

- Manufactured to BSEN 60947 Parts 1 & 3. - Robust enclosure powder coated to RAL7035. - Removable end plates.

CO204

Changeover SwitchesC

hang

eove

r S

witc

hes

Current Rating A(AC21)

No. of Poles

Cable Size (mm2)

Cat. No. H (mm)

W (mm)

D1 (mm)

D2 (mm)

20 2 2.5 TCO202 283 235 125 35

20 3 2.5 TCO203 283 235 125 35

20 4 2.5 TCO204 283 235 125 35

32 2 6 TCO322 283 235 125 35

32 3 6 TCO323 283 235 125 35

32 4 6 TCO324 283 235 125 35

63 2 35 TCO632 420 300 145 40

63 3 35 TCO633 420 300 145 40

63 4 35 TCO634 420 300 145 40

100 4 50 (M8) TCO1004 500 440 175 50

125 4 50 (M8) TCO1254 500 440 175 50

160 4 95 (M8) TCO1604 700 565 190 50

200 4 95 (M8) TCO2004 700 565 190 50

250 4 240 (M10) TCO2504 800 720 220 50

315 4 240 (M10) TCO3154 800 720 220 50

400 4 240 (M10) TCO4004 800 720 220 50

630 4 300 (M12) TCO6304 1300 1300 300 70

800 4 300 (M12) TCO8004 1300 1300 300 70

GRP Enclosures to IP65Current Rating A(AC21)

No. of Poles

Cable Size (mm2)

Cat. No. H (mm)

W (mm)

D1 (mm)

D2 (mm)

20 2 2.5 CO/202 126 101 96 25

20 3 2.5 CO/203 126 101 96 25

20 4 2.5 CO/204 126 101 96 25

32 2 6 CO/322 176 116 111 25

32 3 6 CO/323 176 116 111 25

32 4 6 CO/324 176 116 111 25

63 2 35 CO/632 240 160 169 25

63 3 35 CO/633 240 160 169 25

63 4 35 CO/634 246 160 169 25

100 2 35 CO/1002 240 160 169 25

100 3 35 CO/1003 240 160 169 25

100 4 35 CO/1004 240 160 169 25

TCO1004

Page 45: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Cas

e S

tudy

Innovia FilmsPRO2000 Switchboards

In March 2014, Innovia Films announced that they had signed a contract with the Bank of England for Innovia Security to supply Guardian®

polymer substrate for the next generation of UK sterling bank notes. Proteus Industrial has supplied Innovia Films since 2010 in an on-going

programme of replacing much of their old switchgear with the latest, and in some cases totally bespoke, control equipment. By working closely with Neville Cox, Electrical Engineering Manager - OPP and

his electrical team at Innovia, a new order has just been placed by City Electrical Factors (CEF) Carlisle branch, for two purpose built Pro2000

switchboards to distribute 400v power throughout the state of the art Innovia Security facility as part of the programme.

Designed and built in the Proteus factory in Telford, Neville was able to see his switch board being built to his unique specification. “As a British manufacturer ourselves it is great to be able to talk and actually see our own panel being built” said Neville, “I cannot think of another company

left in the UK that could offer this service”.

Page 46: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200144

- Manufactured to BSEN 61439-1 & 2. - 4 pole configuration. - 6 ratings from 100A to 800A. - 36kA Icc.

H

W D

Higher ratings available on request.

100A Busbar Chambers

Busbar ChambersB

usba

r C

ham

bers

Current Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

100 4 100BC2 400 610 190

100 4 100BC3 400 915 190

100 4 100BC4 400 1220 190

100 4 100BC6 400 1830 190

- Fully rated neutral. - Twin bar design from 100A up to 800A. - Set of 4 clamps supplied with each chamber.

200A Busbar ChambersCurrent Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

200 4 200BC2 400 610 190

200 4 200BC3 400 915 190

200 4 200BC4 400 1220 190

200 4 200BC6 400 1830 190

315A Busbar ChambersCurrent Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

315 4 300BC2 400 610 190

315 4 300BC3 400 915 190

315 4 300BC4 400 1220 190

315 4 300BC6 400 1830 190

400A Busbar ChambersCurrent Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

400 4 400BC2 400 610 190

400 4 400BC3 400 915 190

400 4 400BC4 400 1220 190

400 4 400BC6 400 1830 190

630A Busbar ChambersCurrent Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

630 4 600BC2 400 610 190

630 4 600BC3 400 915 190

630 4 600BC4 400 1220 190

630 4 600BC6 400 1830 190

800A Busbar ChambersCurrent Rating A

No. of Poles

Cat. No. H (mm) W (mm) D (mm)

800 4 800BC3 400 915 190

800 4 800BC4 400 1220 190

800 4 800BC6 400 1830 190

100BC2

200BC3

300BC3

400BC4

600BC6

Page 47: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 45

PR

OTE

US

Bus

bar

Cha

mbe

rs

Connection Bolts

M6 Bolt Size

BLC6/23

Bolts to Suit Busbar

Bolt Size (Metric)

Max. Cable Size mm2

Cat. No.

100-315A rated M6 70 BLC6/23

400-800A rated M6 70 BLC6/48

M8 Bolt SizeBolts to Suit Busbar

Bolt Size (Metric)

Max. Cable Size mm2

Cat. No.

100-315A rated M8 150 BLC8/23

400-800A rated M8 150 BLC8/48

M10 Bolt SizeBolts to Suit Busbar

Bolt Size (Metric)

Max. Cable Size mm2

Cat. No.

315A rated M10 150 BLC10/23

400-800A rated M10 150 BLC10/48

ClampBolts to Suit Busbar

Bolt Size (Metric)

Max. Cable Size mm2

Cat. No.

200-315A rated Clamp 185 BCC185/23

400-800A rated Clamp 185 BCC185/48

400-800A rated Clamp 240 BCC240/48

BLC10/48

BCC185/48

BLC8/23

BCC240/48

Page 48: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200146

ABS EnclosuresA

BS

Enc

losu

res

Description Cat. No. H (mm) W (mm) D (mm)

IP65 enclosure IP65E302013 300 200 130

IP65 enclosure IP65E352515 350 250 150

IP65 enclosure IP65E403022 400 300 220

IP65 enclosure IP65E504024 500 400 240

IP65 enclosure IP65E604020 600 400 200

IP65 enclosure IP65E705025 700 500 250IP65E504024

- Designed to meet protection and combustible standards IP65 and IK08.

- Available in 6 sizes. - Supplied in grey (RAL 7035) with solid door and

base unit (internal mounting plate).

Multipurpose IP65 Enclosures

H

WD

- Wall thickness on the range is 3 – 3.5mm. - Made from UL approved ABS-HB flame retardant

plastic. - Complying with BS EN 60529, BS EN 62208,

CEI23-48 & CEI23-49

Description Cat. No. H (mm) W (mm) D (mm)

IP65 enclosure IP65E302013/CD 300 200 130

IP65 enclosure IP65E352515/CD 350 250 150

IP65 enclosure IP65E403022/CD 400 300 220

IP65 enclosure IP65E504024/CD 500 400 240

IP65 enclosure IP65E604020/CD 600 400 200

IP65 enclosure IP65E705025/CD 700 500 250

Multipurpose IP65 Enclosures

IP65604020/CD

Page 49: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 47

PR

OTE

US

AC1 Rating A

AC3 Rating A

Aux. Contacts Fitted

Cat. No. H (mm) W (mm) D (mm)

25 12 1 NO HLC25 200 200 170

32 22 1 NO HLC32 200 200 170

63 50 1 NO/1 NC HLC63 200 200 170

100 85 1 NO/1 NC HLC100 300 300 170

200 150 1 NO/1 NC HLC200 700 400 300

Con

tact

ors

& E

mer

genc

y S

tops

Contactors & Emergency Stops

EM/STOP

- Compliant with BSEN 60947-4, CSA approved and UL Listing.

- Terminal marking to EN50005. - Climate rating tested to DIN50 016 and IEC68.

Auxilliary contact is rated at 3A/220V a.c.

- Standard 230V a.c. coil voltage. - Generous cabling connections. - Clear identification of contact position and function. - Full range of auxiliary components.

Power Rating (kW) at 400V

AC1 Rating A at 400V

AC3 Rating A at 400V

3 Pole Cat. No.

4 20 9 PC020230V

5.5 25 12 PC025230V

11 32 22 PC032230V

22 63 50 PC063230V

45 100 85 PC100230V

75 200 150 PC200230V

3 Pole Contactors

IP65 Emergency Stop Push ButtonsDescription Contact

ConfigurationCat. No. H (mm) W (mm) D (mm)

Emergency Stop Push Button - Twist release

1NC EM/STOP 72 70 63

N/C Contact Block To Suit EM/STOP - EMCB1NC - - -

N/O Contact Block To Suit EM/STOP - EMCB1NO - - -

IP65 Emergency Stop Push ButtonsDescription Contact

ConfigurationCat. No. H (mm) W (mm) D (mm)

Neon Ind./Twist release* 1NO/1NC MEMI 72 80 50

Key release* 1NO/1NC MEMK 72 80 50

Twist release* 1NO/1NC MEMT 72 80 50

Twist release* 1NO/1NC MEMSS 72 80 50

N/C Contact Block To Suit MEM.... - PCB1NC - - -

N/O Contact Block To Suit MEM... - PCB1NO - - -

Description Cat. No.Auxilliary contact, 1 NO & 1 NC, AC15 duty PCS-11

Auxilliary Contact

Enclosed Heating and Lighting Contactors

Conform to BSEN 60947-4.

MEMI

HLC100

PC063230V

Page 50: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200148

No. of Outgoing Connections

Integral Test Link

Cat. No. L (mm) W (mm) H (mm)

4 No PEB4 245 65 68

6 No PEB6 315 65 68

8 No PEB8 385 65 68

12 No PEB12 525 65 68

6 Yes PEBTL6 470 65 68

8 Yes PEBTL8 540 65 68

12 Yes PEBTL12 680 65 68

Main bolt M12. Outgoing bolts M8.

Earth BarsE

arth

Bar

s

PEB8

- Earth Bars are manufactured from HDHC copper supported on glass reinforced polyester insulators. The CSA of the bar is nominally 150mm² (25mmx6mm / 1”x1/4”) with a current rating of 400A and 300mm2 (30mm x 10mm) for 800A.

L W

H

15kA Is, 30kA peak. 400A Earth Bars

Up to 2000A ratings are available on request.

- The insulators are mounted on a steel ‘top hat’ section for fixing to the wall.

- Mounted on insulated supports (may be used as neutral bars).

No. of Outgoing Connections

Integral Test Link

Cat. No. L (mm) W (mm) H (mm)

6 No PEB6/800 315 65 68

8 No PEB8/800 385 65 68

12 No PEB12/800 525 65 68

6 Yes PEBTL6/800 470 65 68

8 Yes PEBTL8/800 540 65 68

12 Yes PEBTL12/800 680 65 68

Outgoing Connection size M8.

30kA Is, 63kA peak. 800A Earth Bars

Up to 2000A ratings are available on request.

PEBTL12/800

Page 51: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 49

PR

OTE

US

Current Rating (A)

6kA SP Cat No.

10kA SP Cat. No.

10kA DP Cat. No.

6kA TP Cat. No.

10kA TP Cat. No.

10kA 4P Cat. No.

1 601B - - - - -

2 602B 1002/2 - - - -

4 604B 1004/2 - - - -

6 606B 1006/2 - - 31006/2 -

10 610B 1010/2 - - 31010/2 -

16 616B 1016/2 - - 31016/2 -

20 620B 1020/2 - - 31020/2 -

25 625B - - - - -

32 632B 1032/2 - - 31032/2 -

40 640B 1040/2 - - 31040/2 -

45 645B - - - - -

50 650B 1050/2* - - 31050/2* -

63 663B 1063/2* - - 31063/2* -* - 6kA rated.

Miniature Circuit Breakers

601B

B-Type

Current Rating (A)

6kA SP Cat No.

10kA SP Cat. No.

10kA DP Cat. No.

6kA TP Cat. No.

10kA TP Cat. No.

10kA 4P Cat. No.

2 602C 1002/3 - 3602C 31002/3 -

4 604C 1004/3 - 3604C 31004/3 -

6 606C 1006/3 21006/3 3606C 31006/3 41006/3

10 610C 1010/3 21010/3 3610C 31010/3 41010/3

16 616C 1016/3 21016/3 3616C 31016/3 41016/3

20 620C 1020/3 21020/3 3620C 31020/3 41020/3

25 625C 1025/3 21025/3 3625C 31025/3 -

32 632C 1032/3 21032/3 3632C 31032/3 41032/3

40 640C 1040/3 21040/3 3640C 31040/3 41040/3

50 650C 1050/3* 21050/3* 3650C 31050/3* 41050/3*

63 663C 1063/3* 21063/3* 3663C 31063/3* 41063/3** - 6kA rated.

606C

C-Type

Current Rating (A) 6kA SP Cat No.

10kA SP Cat. No.

10kA DP Cat. No.

6kA TP Cat. No.

10kA TP Cat. No.

6 - 1006/4 - - 31006/4

10 - 1010/4 - - 31010/4

16 - 1016/4 - - 31016/4

20 - 1020/4 - - 31020/4

32 - 1032/4 - - 31032/4

40 - 1040/4 - - 31040/4

50 - 1050/4* - - 31050/4*

63 - 1063/4* - - 31063/4*

D-Type

1006/4

- Use the colour code to help identify the supplying Proteus Division for further technical data on circuit protection devices or visit:

www.proteusswitchgear.co.uk

Blue Box - Consumer

No Box - Industrial

* - 6kA rated. 4 Pole MCBs cannot be fitted in MCB boards. C

ircui

t Pro

tect

ion

Page 52: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200150

Circ

uit P

rote

ctio

n

Single Module RCBOs - 1Pole & Solid Neutral

Double Module RCBOs - 1Pole & Switched Neutral

** MRBE range are suitable for ‘cable in-cable out’ applications and with DP comb busbar.

Current Rating (A) 4.5kA Cat No.

6kA Com. Cat. No.

6kA Cat No.

10kA Cat No.

6 6MBRSP 6MBRSPK 66MBRSP XL6BR

10 10MBRSP 10MBRSPK 106MBRSP XL10BR

16 16MBRSP 16MBRSPK 166MBRSP XL16BR

20 20MBRSP 20MBRSPK 206MBRSP XL20BR

25 25MBRSP 25MBRSPK - -

32 32MBRSP 32MBRSPK 326MBRSP XL32BR

40 40MBRSP 40MBRSPK* 406MBRSP XL40BR

45 45MBRSP 45MBRSPK* - XL45BR

XL6BR

B - Type

Current Rating (A) 4.5kA Cat No.

6kA Com. Cat. No.

6kA Cat No.

10kA Cat No.

6 6MCRSP 6MCRSPK 66MCRSP XL6CR

10 10MCRSP 10MCRSPK 106MCRSP XL10CR

16 16MCRSP 16MCRSPK 166MCRSP XL16CR

20 20MCRSP 20MCRSPK 206MCRSP XL20CR

25 - 25MCRSPK - XL25CR

32 32MCRSP 32MCRSPK 326MCRSP XL32CR

40 40MCRSP 40MCRSPK* 406MCRSP XL40CR

45 45MCRSP 45MCRSPK* - XL45CR

C - Type

20MCRSPK

B - TypeCurrent Rating (A) 4.5kA

Cat No.6kA Com. Cat. No.

6kA Cat No.

10kA Cat No.

6 - - 6MRBE** -

10 - - 10MRBE** -

16 - - 16MRBE** -

20 - - 20MRBE** -

32 - - 32MRBE** -

40 - - 40MRBE** -

10MRBE

Residual Current Breaker With Overload - Use the colour code to help identify the supplying

Proteus Division for further technical data on circuit protection devices or visit:

www.proteusswitchgear.co.uk

Blue Box - Consumer

No Box - Industrial

All RCBOs and RCDs are fitted with a ‘Test-Button’ facility which will check the detection and mechanical tripping function of the device, this must be operated regularly.

* - 4.5kA rating.

* - 4.5kA rating.

Type AC Type A

Type AC Type A

Page 53: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 51

PR

OTE

US

Circ

uit P

rote

ctio

n

Current Rating (A)

Max. Cable Size (mm2)

30mA Sensitivity Cat. No.

100mA Sensitivity Cat. No.

300mA Sensitivity Cat. No.

500mA Sensitivity Cat. No.

25 35 25/2/30T 25/2/100T 25/2/300T 25/2/500T

40 35 40/2/30T 40/2/100T 40/2/300T 40/2/500T

63 35 63/2/30T 63/2/100T 63/2/300T 63/2/500T

80 35 80/2/30T 80/2/100T 80/2/300T 80/2/500T

100 50 100/2/30T 100/2/100T 100/2/300T 100/2/500T

Residual Current Device

25/2/30T

Directional Type AC 2 Pole RCDs

- Use the colour code to help identify the supplying Proteus Division for further technical data on circuit protection devices or visit:

www.proteusswitchgear.co.uk

Blue Box - Consumer

No Box - Industrial

25/2/30TA

When the load is connected to the supply through an RCD, the live and neutral conductors are connected through a primary winding on a toroidal transformer. In this arrangement the secondary winding is used as a sensing coil and is electrically connected to a relay or solid-state switching device, the activation of which triggers the mechanical tripping mechanism. When the live and neutral currents are balanced, as in healthy

Residual Current Device - Principles of Operation.circuit they produce equal and opposite magnetic fluxes in the transformer core with the result that there is no current generated in the sensing coil. When the live and neutral currents are not balanced they create an out-of-balance flux. This will induce a current in the secondary sensing winding which is used to operate the tripping mechanism of the RCD.

Current Rating (A) Max. Cable Size (mm2 )

30mA Sensitivity Cat. No.

100mA Sensitivity Cat. No.

300mA Sensitivity Cat. No.

25 35 25/4/30A - -

40 35 40/4/30A 40/4/100A -

63 35 63/4/30A 63/4/100A -

80 35 80/4/30A 80/4/100A -

100 35 100/4/30A 100/4/100A 100/4/300A

Bi-Directional Type A 4 Pole RCDs

Current Rating (A) Max. Cable Size (mm2 )

RCD Sensitivity (mA) Cat. No.

100 (1P+N) 50 100 100/2/100D*

100 (3P+N) 35 100 100/4/100TD

100 (3P+N) 35 300 100/4/300TD

Bi-Directional Time Delay RCDs

Type S - Time delay >150ms. * - Directional

25/4/30A

100/2/100D

Supply can be connected to top or bottom terminals.

Current Rating (A) Max. Cable Size (mm2) 30mA Sensitivity Cat. No.

25 35 25/2/30TA

40 35 40/2/30TA

63 35 63/2/30TA

80 35 80/2/30TA

100 50 100/2/30TA

Directional Type A 2 Pole RCDs

Page 54: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1952 29200152

Insulated IP Enclosures

SPD/T2/TNS4PE

SPD Type IP Rating Earthing Cat. No. H (mm) W (mm) D (mm)

1+2 IP55 TN-S , TN-C-S SPD/T1/TNE 135 75 95

1+2 IP55 TT SPD/T1/TTE 135 75 95

2 (1P+N) IP55 TN-S , TN-C-S SPD/T2/TNE 135 75 95

2 (1P+N) IP55 TT SPD/T2/TTE 135 75 95

2 (1P only) IP55 - SPD/T2/SPE 135 75 95

3 IP55 - SPD/T3/SCE 135 75 95

3 IP55 - SPD/T3/PCE 135 75 95

1+2 (3P+N) IP65 TN-S , TN-C-S SPD/T12/TNS4PE 201 202 120

1+2 (3P+N) IP65 TT SPD/T12/TT4PE 201 202 120

2 (3P+N) IP65 TN-S , TN-C-S SPD/T2/TNS4PE 160 120 95

2 (3P+N) IP65 TT SPD/T2/TT4PE 160 120 95

Type 1 + 2 arrestor is suitable for supplies upto and including 315A.Type 2 arrestor is suitable for supplies upto and including 125A.

SP

D -

Sur

ge P

rote

ctio

n

Surge ProtectionSPD Type Earthing Internal

FuseThree PhaseCat. No.

1 + 2 TN - S, TN - C - S N SPD/T12/TNS4P

1 + 2 TN - S, TN - C - S Y SPD/T12/TNS4PIF

1 + 2 TT N SPD/T12/TT4P

1 + 2 TT Y SPD/T12/TT4PIF

2 TN - S, TN - C - S N SPD/T2/TNS4P

2 TN - S, TN - C - S Y SPD/T2/TNS4PIF

2 TT N SPD/T2/TT4P

2 TT Y SPD/T2/TT4PIF

SPD Type Earthing Internal Fuse

Single PhaseCat. No.

1+2 TN-S , TN-C-S N SPD/T1/TN

1+2 TT N SPD/T1/TT

2 (1P+N) TN-S , TN-C-S N SPD/T2/TN

2 (1P+N) TT N SPD/T2/TT

2 (1P only) - N SPD/T2/SP

3 - N SPD/T3/SC

3 - N SPD/T3/PC

3 - N SPD/T3/LPC

SPD/T3/PC

SPD/T2/TNS4P

Surge ProtectionProteus Switchgear offers a comprehensive range of Lightning and Surge Protection Devices for single and three phase applications. Whether it’s a stand-alone

device or a pre-assembled SPD in a distribution board, Proteus can provide a coordinated system to meet your specific requirements.

Page 55: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 53

PR

OTE

US

MC

B B

oard

s W

ith S

urge

Pro

tect

ion

Blue Box - Consumer

No Box - Industrial

SPD/T12/TNS4PEF

SPD/T2/TT4PES

Steel Enclosures - With Integral FuseSPD Type IP Rating Earthing Cat. No. H (mm) W (mm) D (mm)

1 + 2 - TN-S, TN-C-S SPD/T12/TNS4PEF 385 205 112

1 + 2 - TT SPD/T12/TT4PEF 385 205 112

2 - TN-S, TN-C-S SPD/T2/TNS4PEF 385 205 112

2 - TT SPD/T2/TT4PEF 385 205 112

Steel Enclosures - Without Integral FusesSPD Type IP Rating Earthing Cat. No. H (mm) W (mm) D (mm)

1 + 2 - TN-S, TN-C-S SPD/T12/TNS4PES 385 205 112

1 + 2 - TT SPD/T12/TT4PES 385 205 112

2 - TN-S, TN-C-S SPD/T2/TNS4PES 385 205 112

2 - TT SPD/T2/TT4PES 385 205 112

Surge Protection

BX12S1TNS

XL4S1TT

BXS2TTK

Suitable For Use in TN-C-S/TN-S Systems

MCB Distribution boards c/w Type 2 surge protection suitable for use in TN-C-S / TN-S Systems

Outgoing Ways BX Board 125A Incomer

XL Board 125A Incomer

3 BX4S125TNS XL4S125TNS

5 BX6S125TNS XL6S125TNS

7 BX8S125TNS XL8S125TNS

11 BX12S125TNS XL12S125TNS

15 BX16S125TNS XL16S125TNS

19 BX20S125TNS XL20S125TNS

23 BX24S125TNS XL24S125TNS

Outgoing Ways BX Board 125A Incomer

XL Board 125A Incomer

3 BX4S125TT XL4S125TT

5 BX6S125TT XL6S125TT

7 BX8S125TT XL8S125TT

11 BX12S125TT XL12S125TT

15 BX16S125TT XL16S125TT

19 BX20S125TT XL20S125TT

23 BX24S125TT XL24S125TT

Type of 3ph Board TN-C-STN-S-S

TT

BX BXS2TNSK BXS2TTK

XL XLS2TNSK XLS2TTK

A Type 2 SPD can be connected in parallel with the installation using one of our conversion kit / enclosures which incorporate the necessary Type 2, 3P+N SPD with backup fuse units rated at 125A.

Three phase distribution boards with incomer of 200A rating require a conversion kit to introduce type 2 SPD protection.

Type 1 + 2 arrestor with integral fuse is suitable for supplies over 315A.Type 2 arrestor with integral fuse is suitable for supplies over 125A.

Type 1 + 2 arrestor without integral fuse is suitable for supplies upto and including 315A.Type 2 arrestor without integral fuse is suitable for supplies upto and including 125A.

Page 56: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

54

Page 57: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

55

Circ

uit P

rote

ctio

n

Consumer UnitDivision

For over 30 years, Proteus Switchgear has been at the forefront of British manufacturing - specialising in the production of domestic consumer units and circuit protective devices, working proficiently to supply a full and varied product range. In addition to our standard product range, we have the ability to offer fully bespoke units, tailored to customer needs to suit any individual installation. At Proteus, we are entirely committed to the design and development of our products with the future in mind. Our values insist that we are continuously endeavouring to provide 100% tested products alongside features and benefits that allow us to excel within the Switchgear industry.

Page 58: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711756

Con

sum

er U

nits

Selection and Configurations

This guide to Consumer Units has been compiled in order to assist in understanding the new wiring regulations. However it is not intended to be a substitute for BS7671:2008 which should always be consulted in order to ensure that all installations are constructed in accordance with these regulations.

- Is the Consumer unit being installed in a domestic (household) premise.

(Reg. 421.1.201) i.e metalclad consumer unit.

- To avoid hazards and minimise inconvenience in the event of a fault. Take into account the

danger caused by failure of a single circuit such as a lighting circuit. Reduce the possibility of tripping of an RCD due to excessive protective conductor currents (Reg. 314.1).

- Socket outlets up to 20A must be protected by a residual-current device (Reg. 411.3.3).

- All circuits containing a bath or shower must be RCD-protected (Reg. 701.411.3.3).

- Unprotected cables buried less than 50mm deep in a wall must be RCD-protected.

(Reg. 522.6.202 & 522.6.203).

Isolator Controlled Board

RCD Controlled Board

DPISOLATOR

N

NLSupply

E

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

DPRCD

N

NLSupply

E

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

• Allows the use of single module RCBO devices for individual circuit protection at 30mA.

• Reduces risk of nuisance tripping.• An earth fault on one circuit would not adversely

affect other circuits in the installation.• Can be used as main domestic Consumer Unit.

• Suitable for Grouped Circuit Protection of small numbers of circuits, usually downstream of main consumer unit.

• Typical applications include garages, showers and small extensions.

• If fed from main Consumer Unit also with RCD protection then earth leakage discrimination must be considered.

• Can be used as sub-distribution board, but should not be used as main domestic Consumer Unit.

See page 60 for Metalclad boards (68 for insulated boards)

See page 61 for Metalclad boards (69 for insulated boards)

BS7671:2008 incorporating Amendment 3 is clear about the type of enclosure required for domestic (household) premises – non-combustible (or metal) – but the configuration can vary depending on the type of installation.

Proteus offers a full selection of consumer units to meet both the requirements of BS7671 and each individual application.

Page 59: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 57

PR

OTE

US

Con

sum

er U

nits

Selection and Configurations

DPISOLATOR

DPRCD

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

MCB

MCB

MCB

MCB

MCB

MCB

NL

MainsSupply

NL

N1N2

N2

E

Split Load Board

DPISOLATOR

DPRCD

DPRCD

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

NL

MainsSupply

NL NL

N1N2

N2 N1

E

DPISOLATOR

DPRCD

DPRCD

MCB

MCB

MCB

MCB

MCB

MCB

MCB

MCB

NL

MainsSupply

NL NL

N1N2N3

N3 N2

RCBO / M

CB

RCBO / M

CB

E

Dual RCD Board

High Integrity Dual RCD Board

• Offers both High Integrity ways of Isolator and Grouped Circuit Protection off RCD device.

• Unwanted tripping is limited / restricted.• Variable units allow for increased High Integrity

ways for dedicated circuit protection - e.g. Smoke Alarms.

• Can be used as main domestic Consumer Unit.

• High Integrity circuit ways off the isolator are available for dedicated circuit protection - i.e. Smoke Alarms.

• Dual 30mA RCD configuration offering Grouped Circuit Protection.

• Circuits can be segregated to reduce unwanted tripping.

• Can be used as main domestic Consumer Unit.

• Offers Grouped Circuit Protection using two 30mA RCDs

• Circuits can be segregated to reduce unwanted tripping, for example upstairs lights + downstairs ring main off RCD1 and downstairs lights + upstairs ring main off RCD2.

• Can be used as main domestic Consumer Unit.

See page 62 for Metalclad boards

See page 62 for Metalclad boards

See page 63 for Metalclad boards

NSupply

L2Supply

L1Supply

DPISOLATOR

NE

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

RCBO / M

CB

DPISOLATOR

NN

Dual Tariff Board• For segregation of On Peak and Off Peak

circuits.• Optional split load and isolator incomer options

available.• Additional configurations available upon request.• Can be used as main domestic Consumer Unit.

See page 63 for Metalclad boards

Page 60: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711758

Met

alcl

ad C

onsu

mer

Uni

tsMetalclad Features & BenefitsThis new range of Metalclad Consumer Units from Proteus Switchgear has been designed in conjunction with contractors and housing authorities specifically to meet the requirements of Regulation 421.1.201 of BS7671:2008 incorporating Amendment 3:2015.

With its linear design and matt white (RAL9010) finish, the consumer unit offers the home owner a discreet and contemporary product, whilst providing suitable protection to meet today’s need.

AYXLM Range

6

Full metal enclosure compliant to BS7671 Amendment 3:2015, Reg. 421.1.201.

7

BS EN 61439-3 Compliant.

1 Increased height for added cabling space.

8

Easy access for meter tail connections.

2 Large rear knockouts with radius corners.

3 Comb bus bar / Half Din Rail for quick fitting of devices.

4

Bespoke consumer units made to order.

5

Captive screws with cage nut fixings.

Page 61: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 59

PR

OTE

US

Met

alcl

ad C

onsu

mer

Uni

ts

Metalclad Features & BenefitsRegulation 421.1.201 calls for switchgear assemblies, including consumer units, to be housed in a non-combustible enclosure, incorporating the base, cover, door and any accessories.

The Proteus AYXLM range meets these requirements and offers additional features providing a more versatile product for the installing contractor.

4

12

3

Page 62: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711760

Met

alcl

ad C

onsu

mer

Uni

tsIsolator Incomer Consumer UnitsThe Proteus AYXLM range of metal consumer units are designed and manufactured to BSEN61439 pt 3 and meets the requirements of BS7671:2008, Amendment 3:2015, regulation 421.1.201 - effects against thermal influences specifically for domestic household dwellings.

Manufactured from steel and finished in a polyester powder coating to RAL9010, the AYXLM range provides a comprehensive selection of products to meet the customers requirements.

AYXLM8U Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

Cat. No. H (mm) W (mm) D (mm)

2 63A - - AYXLM2 232 149 110

4 100A - - AYXLM4U 256 201 110

6 100A - - AYXLM6U 256 273 110

8 100A - - AYXLM8U 256 273 110

10 100A - - AYXLM10U 256 309 110

12 100A - - AYXLM12U 256 381 110

14 100A - - AYXLM14U 256 381 110

16 100A - - AYXLM16U 256 417 110

18 100A - - AYXLM18U 256 489 110

20 100A - - AYXLM20U 256 489 110

26 100A - - AYXLM26U 256 597 110

30 100A - - AYXLM30* 500 381 110

Isolator Controlled Consumer Units

* - Double banked.Please refer to page 49 for circuit protection devices.

Page 63: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 61

PR

OTE

US

Met

alcl

ad C

onsu

mer

Uni

ts

RCD Consumer Units

Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

Cat. No. H (mm) W (mm) D (mm)

2 - 63A - AJBXM2U 232 150 110

4 - 63A - AJBXM4U 256 201 110

6 - 63A - AJBXM6U 256 273 110

8 - 63A - AJBXM8U 256 273 110

12 - 63A - AJBXM12U 256 381 110

2 - 80A - AKBXM2U 232 150 110

4 - 80A - AKBXM4U 256 201 110

6 - 80A - AKBXM6U 256 273 110

8 - 80A - AKBXM8U 256 273 110

12 - 80A - AKBXM12U 256 381 110

2 - 100A - ALBXM2U 232 150 110

4 - 100A - ALBXM4U 256 201 110

6 - 100A - ALBXM6U 256 273 110

8 - 100A - ALBXM8U 256 273 110

12 - 100A - ALBXM12U 256 381 110

* - 30mA trip rating.

RCD Incomer Consumer UnitsAJBXM8U

Please refer to page 49 for circuit protection devices.

The AYXLM range of RCD incomer metalclad consumer units are available with 63A, 80A and 100A RCD incomer ratings and 30mA earth leakage protection.

For higher earth leakage protection, 100mA to 500mA, please contact our sales office for further details.

Page 64: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711762

Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

Cat. No. H (mm) W (mm) D (mm)

6 100A 63A 63A AYXLMJB3JB3U 256 309 110

10 100A 63A 63A AYXLMJB5JB5U 256 381 110

10 100A 80A 80A AYXLMKB5KB5U 256 381 110

12 100A 63A 63A AYXLMJB6JB6U 256 417 110

12 100A 80A 80A AYXLMKB6KB6U 256 417 110

16 100A 63A 63A AYXLMJB8JB8U 256 489 110

16 100A 80A 80A AYXLMKB8KB8U 256 489 110

20 100A 63A 63A AYXLMJB10JB10U 256 597 110

20 100A 80A 80A AYXLMKB10KB10U 256 597 110

* - 30mA trip rating.

Dual RCD Consumer UnitsAYXLMJB5JB5U

Please refer to page 49 for circuit protection devices.

Split Load Consumer UnitsOutgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

Cat. No. H (mm) W (mm) D (mm)

6 100A 63A - AYXLMSLV6U 256 273 110

12 100A 63A - AYXLMSLV12U 256 381 110

* - 30mA trip rating.

AYXLMSLV12U

Please refer to page 49 for circuit protection devices.

Met

alcl

ad C

onsu

mer

Uni

tsDual RCD & Split Load Consumer UnitsThis selection of Consumer Units offer the facility to spread the load circuits across one or two 30mA RCDs. Standard configurations listed below supplied with DP

Isolator and RCD/s factory fitted , link leads for both Live and Neutral connections also pre-installed.

Page 65: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 63

PR

OTE

US

Met

alcl

ad C

onsu

mer

Uni

ts

High Integrity & Dual Tariff Consumer UnitsFor applications where ‘High Integrity’ circuit protection is required, for example smoke detectors, these units allow dedicated RCBO installation.

Our standard range of dual tariff consumer units provide dedicated segregation of on peak and off peak circuits.

High Integrity Dual RCD Consumer UnitsOutgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

Cat. No. H (mm) W (mm) D (mm)

6 100A 63A 63A AYXLM1JB2JB3U 256 309 110

10 100A 63A 63A AYXLM2JB4JB4U 256 381 110

12 100A 63A 63A AYXLM2JB5JB5U 256 417 110

14 100A 63A 63A AYXLM2JB6JB6U 256 489 110

16 100A 80A 80A AYXLM4KB8KB8U 256 446 110

20 100A 80A 80A AYXLM4KB8KB8U 256 597 110

6 100A 63A 63A AYXLMDSLV6U 256 309 110

10 100A 63A 63A AYXLMDSLV10U 256 381 110

12 100A 63A 63A AYXLMDSLV12U 256 489 110

16 100A 80A 80A AYXLMDSLV16U 256 489 110

22 100A 80A 80A AYXLMDSLV22U 256 597 110

* - 30mA trip rating.

AYXLM2JB4JB4U

Please refer to page 49 for circuit protection devices.

On Peak Off Peak Cat. No. H (mm) W (mm) D (mm)

100A isolator 6 ways 100A isolator 2 ways AYXLM6Y2U 256 309 110

100A isolator 8 ways 100A isolator 4 ways AYXLM8Y4U 256 381 110

100A isolator 8 ways 100A isolator 6 ways AYXLM8Y6U 256 417 110

100A isolator 10 ways 100A isolator 4 ways AYXLM10Y4U 256 417 110

100A isolator 12 ways 100A isolator 4 ways AYXLM12Y4U 256 446 110

100A isolator 12 ways 100A isolator 6 ways AYXLM12Y6U 256 489 110

100A isolator 10 ways 100A isolator 10 ways AYXLM10Y10U 500 309 110

3 & 3 Dual RCD 100A isolator 2 ways AYXLMJB3JB3Y2U 256 381 110

4 & 4 Dual RCD 100A isolator 4 ways AYXLMJB4JB4Y4U 256 446 110

5 & 5 Dual RCD 100A isolator 4 ways AYXLMJB5JB5Y4U 256 489 110

AYXLMJB5JB5Y4U Dual Tariff Consumer Units

Other configurations available upon request, please speak to our sales office.

Page 66: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711764

The AYXLM range offers a selection of din rail mount enclosures for building your own switchgear assembly. A range of Garage and Shower Units are also available

ensuring compliance with Regulation 421.1.201 of BS7671:2008 incorporating Amendment 3:2015.

Met

alcl

ad C

onsu

mer

Uni

tsEnclosures & Garage / Shower Units

Outgoing Ways

Isolator Rating

RCD 1 Rating*

MCB Rating*

Cat. No. H (mm) W (mm) D (mm)

2 - 40A 6A + 16A APGU2 232 150 110

4 - 40A 6A + 16A APGU4M 256 201 110

1 - 40A 40A APSU95 232 150 110

1 - 63A 50A APSU115 232 150 110

Garage & Shower Units

No. Of Modules

Banks Cat. No. H (mm) W (mm) D (mm)

6 1 APXLM6U 256 201 110

10 1 APXLM10U 256 273 110

12 1 APXLM12U 256 309 110

16 1 APXLM16U 256 381 110

18 1 APXLM18U 256 417 110

22 1 APXLM22U 256 489 110

28 1 APXLM28U 256 597 110

APXLM10UMetalclad Enclosures

Please refer to page 49 for circuit protection devices.

Please refer to page 49 for circuit protection devices.

APGU2

Page 67: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 65

PR

OTE

USTo compliment the AYXLM range of Metalclad consumer

units, a selection of spacer mounts are available for use where retrofitting to surface mount cables are necessary.

In addition, Meter Tail glands are available for providing Class II insulation protection for incoming supply cables.

Met

alcl

ad C

onsu

mer

Uni

ts

Metalclad Accessories

No. Of Modules

Banks Cat. No. H (mm) W (mm) D (mm)

6 1 ASM6 256 201 20

10 1 ASM10 256 273 20

12 1 ASM12 256 309 20

16 1 ASM16 256 381 20

18 1 ASM18 256 417 20

22 1 ASM22 256 489 20

28 1 ASM28 256 597 20

Consumer Unit Spacer Mounts

Description Cat. No. Key lock for A type metalclad consumer units AKL

Intumescent putty pad (210mm x 148mm x 3mm) IP21X15

Safety Accessories

AKL

ASM12

MTGP40B

Description Cat. No. Dia (mm)

Meter tail gland pack (2x25mm / 1x 16mm) M32 - brass MTGP32B 32

Meter tail gland pack (2x25mm / 1x 16mm) M40 - brass MTGP40B 40

Meter tail gland pack (2x25mm / 1x 16mm) M32 - plastic MTGP32P 32

Meter tail gland pack (2x25mm / 1x 16mm) M40 - plastic MTGP40P 40

Meter tail reducer 40-32mm MTGPR40/32 -

Meter Tail Gland Pack

Page 68: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711766

Insulated Features & BenefitsIn

sula

ted

Con

sum

er U

nits

1 Unique stacking system.

2 Removable endplates for maximum cable access.

6 Increased height for added cabling space.

8 Translucent front door.

3 Comb bus bar / Half Din Rail for quick fitting of devices.

4 Rear, side and top/bottom cable entries.

9 Manufactured from thermoplastic materials to BS 60695.

10 Bespoke consumer units made to order.

5 Captive four point 1/4 turn cover fixing screws.

7 BS EN 61439-3 Compliant.

The YXL range of Consumer Units has quickly become one of the most innovative insulated boards in the market. Developed through a keen interest in customer feedback, Proteus Switchgear created a Consumer Unit that was flexible to any imaginable on-site scenario. The

various options available include Dual RCD units and also Dual RCD units with High Integrity option - suitable for single module RCBO devices, offering complete peace of mind for those essential circuits requiring

YXL Range

Page 69: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 67

PR

OTE

US

Insulated Features & Benefits

Insu

late

d C

onsu

mer

Uni

ts

dedicated earth fault protection. In this range, Proteus Switchgear also offer the largest single bank insulated Consumer Unit on the market, the 25-module Consumer unit, with up to 23 outgoing circuit ways.

Page 70: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711768

For Isolator controlled Consumer Units with over 30 outgoing ways contact factory for availability.

* - Cannot be banked** - Double banked unit*** - Triple banked unit

YXL# units are supplied with translucent cover.Please refer to page 49 for circuit protection devices.

YXL6

Insu

late

d C

onsu

mer

Uni

tsIsolator Incomer Consumer Units

Isolator Controlled Consumer UnitsOutgoing Ways

Isolator Rating (A)

No. of Modules

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

1 45 4 YXL1* 230 116 110 220

2 63 4 YXL2* 230 116 110 220

3 63 6 YXL3* 230 152 110 220

4 100 6 YXL4* 230 152 110 220

6 100 10 YXL6 230 252 106 205

8 100 10 YXL8 230 252 106 205

12 100 16 YXL12 230 359 106 205

14 100 16 YXL14 230 359 106 205

16 100 18 YXL16* 230 390 110 220

18 100 20** YXL18 460 252 106 205

21 100 25 YXL21* 230 511 110 220

23 100 25 YXL23* 230 511 110 220

30 100 32** YXL30 460 359 106 205

Readily available from 1 to 30 usable ways, our Isolator Incomer Consumer Units allow the use of single module RCBO devices for individual circuit protection at 30mA, reducing the risk of nuisance tripping.

Our insulated enclosures are manufactured from light grey impact resistant and flame retardant thermoplastic.

Page 71: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 69

PR

OTE

US

RCD incomer units are available in higher earth leakage sensitivity options on request.* - Insulated boards which cannot be banked.

Please refer to page 49 for circuit protection devices.

RCD Incomer Consumer Units

Insu

late

d C

onsu

mer

Uni

ts

RCD Controlled Consumer UnitsOutgoing Ways

Isolator Rating (A)

No. of Modules

Cat. No. Standard Range

H (mm)

W (mm)

D1 (mm)

D2 (mm)

1 25A 4 GBX1* 230 116 110 220

2 25A 4 GBX2* 230 116 110 220

3 25A 6 GBX3* 230 152 110 220

4 25A 6 GBX4* 230 152 110 220

1 40A 4 HBX1* 230 116 110 220

2 40A 4 HBX2* 230 116 110 220

3 40A 6 HBX3* 230 152 110 220

4 40A 6 HBX4* 230 152 110 220

6 40A 10 HBX6 230 252 106 205

1 63A 4 JBX1* 230 116 110 220

2 63A 4 JBX2* 230 116 110 220

3 63A 6 JBX3* 230 152 110 220

4 63A 6 JBX4* 230 152 110 220

6 63A 10 JBX6 230 252 106 205

8 63A 10 JBX8 230 252 106 205

10 63A 14 JBX10 200 320 106 205

12 63A 14 JBX12 200 320 106 205

4 80A 6 KBX4* 230 152 110 220

6 80A 10 KBX6 230 252 106 205

8 80A 10 KBX8 230 252 106 205

10 80A 14 KBX10 200 320 106 205

12 80A 14 KBX12 200 320 106 205

6 100A 10 LBX6 230 252 106 205

8 100A 10 LBX8 230 252 106 205

10 100A 14 LBX10 200 320 106 205

12 100A 14 LBX12 200 320 106 205

GBX4

Readily available from 1 to 12 usable ways, our RCD Incomer Consumer Units are suitable for grouped circuit protection for a small number of circuits, typically installed in addition to a property’s main Consumer

Unit – applications such as garages, showers and small extensions. Our ranges of RCD Incomer Consumer Units are pre-fitted with a 30mA RCD Incomer, with ratings ranging from 25A – 100A.

Page 72: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711770

Enclosures/Multi-Purpose UnitsE

nclo

sure

s/M

ulti-

Pur

pose

Uni

ts Build your own consumer unit or multi-purpose board. Just clip on your required equipment to the DIN Rail and if necessary fit the Comb Busbar.Fitted with full DIN rail, Earth and Neutral terminal bars.

Multi-Purpose Units

* - Insulated enclosures which cannot be banked.** - Double banked unit.

No. Of Modules

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

4 PXL4* 230 116 110 220

6 PXL6* 230 152 110 220

10 PXL10 230 252 106 205

16 PXL16 230 359 106 205

18 PXL18* 230 390 110 220

20 PXL20** 460 252 106 205

25 PXL25* 230 511 110 220

32 PXL32** 460 359 106 205

PXL4

Please refer to page 49 for circuit protection devices.

Please refer to page 49 for circuit protection devices.

Surface mounting units suitable for use with Proteus modular isolation and protection devices to provide local or individual circuit control eg. Workshop.For extra wiring room order extended enclosures eg. ENC202ML or ENC204ML.

* - Enclosure supplied without transparent front cover.

Insulated IP Enclosures

No. of Modules

IP Rating Cat. No. H (mm) W (mm) D (mm)

1 or 2 20 ENC202* 135 40 65

4 20 ENC204* 135 75 65

4 40 ENC404 230 116 110

2 55 ENC542 135 75 95

4 55 ENC544 160 120 95

6 55 ENC546 160 200 95

10 55 ENC5410 196 250 110

16 55 ENC5416 270 340 140

4 65 ENC654 200 127 120

8 65 ENC658 200 200 120

12 65 ENC6512 258 318 142

24 65 ENC6524 383 318 142

36 65 ENC6536 507 318 142

ENC654

Page 73: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Sheffield City CouncilNew Build Homes

As part of a new build project, Sheffield City Council chose Proteus Switchgear to develop a range of Flush-Mounted Consumer Units to incorporate a dual RCD / high integrity configuration including a PV

monitoring and data-logging/transmission module.The units were designed to meet the requirements of Amendment 3:2015

of BS7671:2008 - Requirements for Electrical Installations. Cas

e S

tudy

Page 74: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711772

Metering Isolators & TerminalsM

eter

Isol

ator

Pro

duct

s

Description Cat. No. H (mm)

W (mm)

D (mm)

Terminal Capacity

100A 1P+N isolator EMIS 145 59 82 upto 35mm2

100A 1P+N isolator - LHS neutral EMISN 145 59 82 upto 35mm2

24Hr/Off peak insulated EMIS2 145 95 82 upto 35mm2

100A 3P+N isolator EMIS4P 145 95 82 upto 35mm2

EMIS

Single & 3 Phase Isolators

Single and three phase isolator switches specifically for metering applications.Facility to seal the enclosure cover and incoming ‘bottom’ connections, allowing the outgoing ‘top’ connections to be made at a later stage.

Removable terminal cover can also be sealed if required.Entry holes will accommodate 25mm2 double insulated or 35mm2 single insulated cable.

Description Cat. No. No. of Modules45A Direct connect MID approved kWh meter KWH45AMID 1

100A Direct connect MID approved kWh meter KWH100AMID 2

Kilowatt Hour Meters

Description Cat. No. H (mm)

W (mm)

D (mm)

Terminal Capacity

100A 5 Way terminal block ETB5 64 50 40 upto 35mm2

100A 5 Way terminal block, blue ETB5BL 64 50 40 upto 35mm2

100A 5 Way terminal block, brown ETB5BR 64 50 40 upto 35mm2

Terminal Block

ETB5

KWH100A

Description Cat. No. H (mm)

W (mm)

D (mm)

Terminal Capacity

100 Amp heating contactor EHC1 110 90 84 upto 35mm2

100 Amp heating contactor, switched live version

EHC1L 110 90 84 upto 35mm2

100 Amp heating contactor,3 phase version

EHC3 146 195 84 upto 35mm2

Single & 3 Phase Heating Contactors

EHC1

Page 75: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 73

PR

OTE

US

Switch Fuse & Fire Alarm Switches

Sw

itch

Fuse

/Fire

Ala

rm S

witc

hes

Double Pole HRC Switch Fuses

DP Isolator can be locked in the ON or OFF position using DLPX1.

4 pole Isolator Switch AC21B

Fire Alarm Panel Switch

For use when connecting a fire alarm to a public or private power distribution supply. Key features:

Compliant with B5839 pt 1-2002 & BSEN54 pt4-1997Three module steel enclosure.

Powder coated red in colour.45A DP Isolator and 6A Type B SP MCB fitted

Both devices can be locked in the ‘ON’ position using locking accessories supplied.Metalclad surface mounting enclosure with both top and bottom knockouts.

Ingress protection: IP20.(NB: MCB will trip under fault conditions even when lock is fitted).

Surface mounting switch disconnector fuse unit in robust steel enclosure with an epoxy powder coated paint finish. Unit is designed to accommodate fuselinks to BS88: Part 1,2 & 6.All switches are lockable in ON and OFF position.

Surface mounting 4pole switch disconnectors compliant with IEC 60947-3 with AC21B utilisation category. This unit offers a high impact resistant metalclad enclosure with facility to lock the switch in ON

and OFF positions.

Current Rating Capacity In (mm2)

Capacity Out (mm2)

Cat No. H (mm) W (mm) D (mm)

20 50 25 SF20 225 114 90

32 50 25 SF32 225 114 90

40 50 25 SF40 225 114 90

50 50 25 SF50 225 114 90

63 50 25 SF63 225 114 90

80 50 50 SF100/80 307 192 93

100 50 50 SF100 307 192 93

Description Capacity In (mm2)

Capacity Out (mm2)

Cat No. H (mm) W (mm) D (mm)

Metalclad unit 50 25 FS1 175 110 85

Description Capacity In (mm2)

Capacity Out (mm2)

Cat No. H (mm) W (mm) D (mm)

32A 10 10 TPS30 140 81 60

SF20

FS1

TPS30

Page 76: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711774

Three Phase Consumer UnitsTh

ree

Pha

se C

onsu

mer

Uni

ts

Insulated Enclosures

When space is limited and the installation requires a three phase distribution board, the range of Proteus TPX consumer units is the solution.A choice of 1 to 4 outgoing TP ways fed via a 3-phase

* - Will accept metal gland plate MGP2.** - Will accept metal gland plate MGP3.

comb busbar arrangement are available in either insulated, metalclad or IP55 enclosures.All units are pre-fitted with 100A TP Isolator incomer and busbar to suit.

No. of Modules

Cat. No. H (mm) W (mm) D1 (mm) D2 (mm)

1 TPXIC1 230 250 105 220

2 TPXIC2 * 230 250 105 220

3 TPXIC3 ** 200 320 105 220

4 TPXIC4 ** 230 360 105 220

IP55 EnclosuresNo. of Modules

Cat. No. H (mm) W (mm) D (mm)

1 TPXIPC1 150 190 90

2 TPXIPC2 190 250 115

3 TPXIPC3 270 340 130

4 TPXIPC4 270 340 130

Metal EnclosuresNo. of Modules

Cat. No. H (mm) W (mm) D (mm)

1 TPXMC1 254 167 108

2 TPXMC2 254 237 108

3 TPXMC3 254 307 108

TPXMC2

TPXIPC1

TPXIC4

Please refer to page 49 for circuit protection devices.

Please refer to page 49 for circuit protection devices.

Please refer to page 49 for circuit protection devices.

Page 77: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 75

PR

OTE

US

Cas

e S

tudy

Gainsborough Hotel Finning UKFlush Mount Consumer Units

As part of a major refurbishment program by Finning UK, Proteus Flush Mount Consumer Units were selected for the prestigious 100 bedroom

Gainsborough Hotel in Bath.

The units were supplied pre-assembled with SCPDs and contactors already fitted, ready for immediate installation. In addition, provision was

made in the Consumer Units to mount a secondary heating controller supplied by the contractor.

Page 78: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711776

Digital, Mechanical & Staircase TimersTi

mer

s

Digital TimersNo. of Channels Current Rating (A)

Resistive LoadCat. No.

1 16 71ST

2 16 72ST

71ST

Mechanical Timers

* Pre-warn function ensures that the timed light circuit ‘flashes’ on and off several times before fully switching off.

Staircase Timers

No. of Channels Cat. No. Module Size1 Channel 24hr synchronous timer 16A rated 241S 1

2 Channel 24hr synchronous timer 16A rated 242S 3

1 Channel 24hr quartz timer 16A rated 241SQ 1

2 Channel 24hr quartz timer 16A rated 242SQ 3

No. of Channels Cat. No.Staircase timer switch 1 module 1SCT

Staircase timer switch 1 module c/w pre-warn function 1SCT/P*

65.549.5

44.060.0

17.5

45.090.0

3 4

21

65.549.5

17.9

45.085.0

LN 2

1

65.5

49.5

44.060.0

52.5

45.085.0

1 2 3 4 5

N

L

21M

3 4

LOAD

N

L

L

N 2

1

N

L

L

N 2

1

Wiring schematic and Dimensions/Terminal arrangement1 NO contact 24hr

Dimensions/Terminal arrangement

3-wire 4-wire

N

L2 3 4 51

M

LOAD

1 Changeover contact 24hr

65.749.1

44.060.0

17.5

45.090.0

N

L1

3 2

1 2 3 4

5 6 7 8

65.749.1

44.060.0

35.0

45.090.0

N

L

N

M

3 2L1

LOAD

CH1

Wiring schematic and Dimensions/Terminal arrangement1 channel digital timer 2 channel digital timer

N

L

M

6 7 85

LOAD

CH2

2 3 41

CH1

L

N

242S

1SCT

A range of digital, mechanical & staircase timers available in 24-hour or 7-day options, predetermining the scheduling of automated switching options.

Page 79: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 77

PR

OTE

US

Contactor & Isolators

Isolators

65.549.5

44.060.0

53.435.7

45.084.5

1 3 5

A1A1

A2A2

71 3 5 7

2 4 6 82 4 6 8

65.8

50.0

44.5

60.3

18.3

45.581.5

42

1 3

A1

A2

Dimensions/Terminal arrangement2 pole contactor 4 pole contactor

Proteus contactors are available from 20A up-to 63A in 2pole and 4pole options, suitable for din-rail mounting in consumer units fitted with full standard din-rail.Contactors offer method of remote switching of loads

66.049.8

43.572.5

70.017.5 35.0 52.5

45.085.0

Key features:Choice of current ratings from 45A up to 100A.

Operating dolly can be locked in ON or OFF state.Neutral pole designed to ‘make first / break last’.

Positive contact status indication therefore can be used as an isolating switch.Switch disconnector is designed to accept cable-in/cable-out and direct to

busbar connection.

and are suitable for AC1 switching - general heating and lighting loads.All contactors supplied with normally open (NO) contacts.Standard: EN61095.

Contactors - Normally OpenCurrent Rating (A)

Voltage Rating

(V)

Power at Rated Voltage AC 1 (kW)

Power at Rated Voltage AC 3 (kW)

No. of Poles

No. of Modules

Cat. No.

20 400 4 - 2 1 CT202

20 400 16 4 4 2 CT204

40 400 25 8 4 3 CT404

63 400 37 15 4 3 CT634

Current Rating (A)

DP Cat. No. TP Cat. No. 4P Cat. No.

45 45S2 45S3 -

63 63S2 63S3 63S4

100 100S2 100S3 100S4

Con

tact

ors

& Is

olat

ors

CT202

100S2

Contactors - Normally ClosedCurrent Rating (A)

Voltage Rating

(V)

Power at Rated Voltage AC 1 (kW)

Power at Rated Voltage AC 3 (kW)

No. of Poles

No. of Modules

Cat. No.

20 400 4 - 2 1 CT202NC

20 400 16 4 4 2 CT204NC

40 400 25 8 4 3 CT404NC

63 400 37 15 4 3 CT634NCCT202NC

Page 80: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711778

AccessoriesA

cces

sorie

s

Barriers & LockingDescription Cat. No.Blanking plate B1

Busbar terminal shroud BBS1

Blanking module BM1

MCB Dolly locking device DLPX1

MCB Dolly locking device c/w padlock DLPX1PBM1

* - 80A max. 100A intermittent rating.

Insulated Comb Busbars *Description Cat. No.Insulated comb busbar 19 SP ways CB19SP

Insulated comb busbar 28 SP ways CB28SP

Insulated comb busbar 8 DP ways CB8DP

Insulated comb busbar 12 DP ways CB12DP

Insulated comb busbar 7 TP ways CB7TP

Insulated comb busbar 12 TP ways CB12TP

End Cap For DP/TP Insulated comb busbar CBC3

Cable terminal for insulated comb busbar CBCT1

CB19SP

Page 81: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 79

PR

OTE

US

Accessories

Acc

esso

ries

BS88 Fuses (Offset Tag)

Brass Terminal BarsDescription Cat. No.5 Hole terminal bar TB5

8 Hole terminal bar TB8

10 Hole terminal bar TB10

12 Hole terminal bar TB12

14 Hole terminal bar TB14

16 Hole terminal bar TB16

Description Cat. No.20A BS88 HRC Fuse PES20

32A BS88 HRC Fuse PES32

40A BS88 HRC Fuse PES40

50A BS88 HRC Fuse PES50

63A BS88 HRC Fuse PES63

63A BS88 HRC Fuse (Fits SF100 & SF100/80) PXS63

80A BS88 HRC Fuse PXS80

100A BS88 HRC Fuse PXS100

TB8

PXS100

BS88 FusesDescription Cat. No.20A BS88 HRC Fuse PMS20

32A BS88 HRC Fuse PMS32

40A BS88 HRC Fuse PMS40

50A BS88 HRC Fuse PMS50

63A BS88 HRC Fuse PMS63

63A BS88 HRC Fuse (Fits SF100 & SF100/80) PMS63

80A BS88 HRC Fuse PMS80

100A BS88 HRC Fuse PMS100

PMS100

Page 82: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

+44 (0) 1527 51711780

Custom Built Consumer UnitsS

peci

als At Proteus, our custom build service ensure we

design and manufacture a diverse range of insulated and metalclad consumer units to meet your specific requirements.

Larger than average homes require larger than the average Consumer Units, building bulk quantities to specification is

made simple when specifying Proteus Switchgear.

Street Lighting ApplicationsSpecial locations often require special solutions. A street lighting application

demanded a compact unit incorporating Double Pole RCBO, a 2 pole contactor and a 7 day digital timer. Proteus Switchgear were able to offer a pre-cabled and configured

unit with electrical noise suppression component included to meet this customers specification.

Multiple Banked Units

Bespoke Units

- Insulated, IP rated or metalclad units.

- Multiple distribution options.

- Optional circuit control devices.

- Pre-wired short circuit protective devices.

- Fully tested assembly.

Page 83: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

www.proteusswitchgear.co.uk 81

PR

OTE

US

Mantel Consumer Units

Man

tel U

nits

Proteus offer a variety of Mantel Consumer Units (also known as skeleton or spine units) to meet and comply with the recent changes in the wiring regulations.Designed and developed with the needs of both the installer and installation conditions in mind these units offer

Dual RCD Spine Units

High Integrity & Dual RCD Spine Units

Split Load Spine Units

SKSLV6R4

SK3JB12

SKJB5JB5

Please refer to page 49 for circuit protection devices.

Key features:16 module units.Pre-wired switchgear where applicable.Clean cover plate / barrier of non-combustible material.

Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

RCD Type Cat. No. H (mm) W (mm) D (mm)

10 3 7 - 63A DP 30mA SK3JB7 250 333 92

10 4 6 - 63A DP 30mA SK4JB6 250 333 92

10 5 5 - 63A DP 30mA SK5JB5 250 333 92

10 6 4 - 63A DP 30mA SK6JB4 250 333 92

10 7 3 - 63A DP 30mA SK7JB3 250 333 92

10 up-to 7 up-to 7 - 63A DP 30mA SKSLV12 250 333 92

Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

RCD Type Cat. No. H (mm) W (mm) D (mm)

8 - 4 4 63A DP 30mA SKJB4JB4 250 333 92

10 - 5 5 63A DP 30mA SKJB5JB5 250 333 92

Outgoing Ways

Isolator Rating

RCD 1 Rating*

RCD 2 Rating*

RCD Type Cat. No. H (mm) W (mm) D (mm)

10 up-to 4 6 4 63A DP 30mA SKSLV6R4 250 333 92

10 2 4 4 63A DP 30mA SK2JB4JB4 250 333 92

Please refer to page 49 for circuit protection devices.

Please refer to page 49 for circuit protection devices.

Page 84: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

82

Technical InformationTe

chni

cal I

nfor

mat

ion

Type Instantaneous Tripping Range

Circuit Applications

B 3 - 5 Used in domestic situations where maximum sensitivity is required and very little equipment with high start-up current is connected.

C 5 - 10 Suitable for commercial / industrial situations where close protection is not required and start up currents of devices can run upto 5 times rated current for a short period. Where many low voltage lights are used in a domestic situation then, due to the inrush currents of the transformers, type C MCBs may be required to avoid nuisance tripping.

D 10 - 20 Suitable for industrial application where start-up currents may be up to 10 times rated current, for example protection for machines with electric motors fitted, welding units etc.

Miniature Circuit BreakersProteus MCBs are of thermo-magnetic, current limiting type and are available in a range of kA ratings (4.5kA up to 10kA) and operating characteristics (Type B, C and D). A selection of SP (single pole), DP (double pole) and TP (triple pole) options are offered. - All MCBs have a ‘trip free

mechanism’.

12060

20105

21

30

105

210.5

0.20.10.05

0.020.010.005

0.0020.0010.0005

Seco

nds

Min

utes

1 2 3 4 5 6 7 8 10 15 20 30 40 50I / In

B C D

2

3 4 5 6 7 8

1

MCB Tripping Curves - Positive contact status indication

in accordance with IEE wiring regulations.

- Tunnel design, touch proof and captive terminals.

- Can be used as isolating switches. - Lockable in both ON and OFF state

without affecting the ability of the trip mechanism to operate.

Standards:Operating voltage:Operating frequency:Ambient operating temp.:Maximum terminal torque:Enclosure material:Supply:IP rating:Dielectric voltage:Insulation voltage:

BSEN 60898230 / 400V a.c.50Hz-5C to +40C3Nm (2.5Nm advised) Urea or V0 rated Polyamide (self extinguishing at 960C)Can be supplied from top or bottom.IP4X (front face) IP20 (terminals)2500V a.c.500V a.c.

Terminal CapacitiesRange of MCBs Capacity (mm2)MCBs 25mm2 (In and Out)

RCBOs 25mm2 (In) ; 10mm2 (Out)

RCDs (<100A) 35mm2 (In and Out)

RCDs (100A) 50mm2 (In and Out)

Isolators 35/50mm2 (In and Out)

Earth and Neutral bars 25mm2 and 16mm2

General Specification

1

2

3

4

5

6

7

8

Steady current value 1.13xIn: t>1hrAll MCBs are capable of carrying full load current continuously (derating factors apply for ambient conditions and no. of circuits within an enclosure).

Steady current value 1.45xIn: t<1hrAs load current increases above current rating the thermal release mechanism will disconnect MCB. B

-Type

D-Type

C-Type

3xIn: 0.1sec<t<45sec (In<=32A)3xIn: 0.1sec<t<90sec (In>32A)MCB will trip within times specified.

5xIn: t<0.1secB-type MCB ensured to trip in less than 0.1sec via magnetic release.

5xIn: 0.1sec<t<15sec (In<=32A)5xIn: 0.1sec<t<30sec (In>32A)MCB will trip within times specified.

t = Tripping time

10xIn: 0.1sec<t<4sec (In<=32A)10xIn: 0.1sec<t<8sec (In>32A)MCB will trip within times specified.20xIn: t<0.1secD-type MCB ensured to trip in less than 0.1sec via magnetic release.

10xIn: t<0.1secC-type MCB ensured to trip in less than 0.1sec via magnetic release.

MCB Installation VoltagesType B & C 1 pole 230V-400V AC

Type B & C Multi-pole 400V AC

Page 85: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

83

PR

OTE

US

Technical Information

Tech

nica

l Inf

orm

atio

n

Switchgear DeratingAdjacent MCBs, RCBOs or MCB/RCD combinations should not be continuously loaded at, or approaching, their normal rated currents when mounted in enclosures. It is also good engineering practice to make provisions for adequate free air between devices.Under these circumstances and, in common with other

manufacturers, we recommend a diversity factor of 66% is applied to the MCB nominal rated current, especially if the MCB is expected to be loaded near to or at full rating for more than one hour.Thermal issues should also be taken into consideration when choosing conductor size for the protected circuits.

MCB Installation CurrentsGenerally the MCBs detailed are not intended to provide close overload protection for motors. However they can be employed in conjunction with the customary motor overload current device as an alternative to the isolator/fuse combination. In this condition the MCB will protect the cable to the motor and the motor will be protected by its own protective device.The tables A and B detailed below give recommendations on MCB selection for motor circuits, for C type only.Note: The values of full load current and starting current will approximately be 10% higher at 380/220V ac than the figures

stated for 400/230V motors. The figures given in table A for the starting current and its duration are intended to be used as a guide only. In practice the motor run up time will depend upon the type of drive and the loading of the motor when it is started. Consultation with the motor manufacturer should give an indication of the magnitude of the starting current and the duration.The selection of the most suitable circuit breaker can then be found from the time/current characteristics of the circuit breaker.

Table A: Recommended MCB current ratings for the protection of cables to single phase 230V a.c. motors.

Horse Power (HP)

Power (kW) FLC (A) Starting Current (A)

Duration of Starting Current (sec)

MCB Current Rating (A)

0.25 0.18 1.5 10.5 3.0 10

0.50 0.37 3.0 21.0 3.0 10

0.75 0.55 5.0 35.0 3.0 16

1.00 0.75 5.5 38.5 3.1 20

1.50 1.12 8.5 59.5 3.15 32

2.00 1.50 10.5 73.5 3.2 50

3.00 2.25 15.5 108.0 3.3 50

4.00 3.00 20.0 140.0 3.4 63

5.00 3.80 24.0 168.0 3.5 -

6.00 4.50 28.0 196.0 3.6 -

7.00 5.20 32.0 224.0 3.7 -

Maximum Earth fault loop impedance (ie Zs ohms) for circuits supplying socket outlets in accordance with BS7671 regulation 411.3.2 at @ 218.5V (230V x 0.95 Cmin)

At these levels of earth loop impedance, MCBs will provide disconnection times in accordance with BS7671 for circuits supplying socket outlets .

BS7671: 2008 requirements: Electrical installations (17th Edition of the IEE Wiring regulations) specifically identifies Type B and C. Lower earth fault loop impedance’s (Zs) are generally necessary for Type D to achieve the operating times required by regulation 413-02-08. (Maximum Zs is calculated using the formula in the regulations and the characteristics of the circuit breaker). Where the requirement can not be achieved, use of the circuit breakers

as overcurrent protective devices is not precluded, but the use of residual current circuit breakers (RCDs) to provide protection against indirect earth fault condition is implied. Establishment of the value of the earth fault loop impedance (Zs) at the design stage of installation will determine which type of circuit breaker should be used.

Device Standard 6A 10A 16A 20A 32A 40A 50A 63A 80A 100A 125AType B BSEN 60898 7.43 4.46 2.79 2.23 1.39 1.11 0.89 0.71 - - -

Type C BSEN 60898 3.83 2.30 1.44 1.15 0.72 0.58 0.46 0.37 0.30 0.24 0.19

Type D BSEN 60898 1.87 1.12 0.70 0.56 0.35 0.28 0.22 0.18 - - -

Page 86: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

84

Technical InformationTe

chni

cal I

nfor

mat

ion

Table B: Recommended MCB current ratings for the protection of cables to three phase 400V a.c. motors.

Horse Power (HP)

Power (kW)

FLC (A)

Starting Current (A)

Duration of Starting Current (sec)

MCB Current Rating (A)

Starting Current (A)

Duration of Starting Current (sec)

MCB Current Rating (A)

0.25 0.18 0.5 3.5 3.0 6 1.75 9.0 6

0.50 0.37 0.9 6.3 3.0 6 3.15 9.1 6

0.75 0.55 1.3 9.1 3.0 6 4.59 9.2 6

1.00 0.75 1.9 13.3 3.1 6 6.6 9.3 6

1.50 1.12 2.5 17.5 3.15 10 8.7 9.5 10

2.00 1.50 3.4 23.8 3.2 10 11.9 9.6 10

3.00 2.25 4.8 33.6 3.3 16 16.8 10.0 16

4.00 3.00 6.4 44.8 3.4 20 22.4 10.3 20

5.00 3.80 7.8 54.6 3.5 20 27.3 10.7 20

6.00 4.50 9.0 63.0 3.6 20 31.5 11.0 20

7.00 5.20 10.3 72.1 3.7 32 36.0 11.3 20

7.50 5.60 11.6 81.2 3.75 32 40.6 11.5 32

10.00 7.50 14.4 100.8 4.0 40 50.4 12.3 40

12.50 9.30 17.3 121.1 4.25 40 60.5 13.2 40

15.00 11.00 21.1 148.0 4.5 63 73.8 14.0 50

20.00 15.00 28.0 196.0 5.0 63 93.0 15.7 63

25.00 18.50 35.0 245.0 5.5 - 122.0 17.3 -

7.00 5.20 32.0 224.0 3.7 -

RCBOs Providing both overcurrent protection and earth leakage protection in a combined unit, Proteus offers a range of RCBOs which will fit all Proteus modular consumer units and B-type 3-phase distribution boards.RCBOs are available in a range of current ratings from 6A to 50A and with short circuit capacities (Ics) from 4.5kA up to 10kA. RCBOs are offered in both type B and C tripping characteristics.All single module RCBOs contain a switched live and solid neutral where as the double module unit offers both Live and Neutral switching.Similar to our MCB technology all devices have a ‘trip free

Standards:Operating voltage:Earth leakage sensitivity:Switching:

Operating frequency:Ambient operating temp.:Maxi. terminal torque:Enclosure material:Supply connections:IP rating:Dielectric voltage:Insulation voltage:

BSEN 61009230V a.c.30mASingle pole - L (switched) + N (solid) Double pole - L + N (switched)50Hz -5°C - +40°C2NmUrea or VO rated PBT (both self extinguishing at 960°C)Consult specific product data sheetIP4X (front face); IP20 (terminals)2500V a.c.500V a.c.

General Specification

mechanism’ and positive contact status indication. Connection of load circuit cables is via tunnel design cable clamps with touch proof and captive terminal screws. Lockable in both ON and OFF position without affecting the ability of the trip mechanism to operate.RCBOs allow earth fault protection to be restricted to individual circuits, thus ensuring that only the circuit with the fault is interrupted. (When groups of circuits are protected by an RCD, all circuits would be interrupted under a fault condition, which may cause unnecessary inconvenience).

Page 87: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

85

PR

OTE

US

Type 1 SPDs are key to providing necessary protection of the installation against the effects of lightning strikes entering the building. Type 1 SPDs are designed to carry partial lightning currents and are defined as being tested with a high energy 10/350μs (Iimp) wave shape.

These Type 1 SPDs must be installed on incoming services (e.g. mains power and data) when an external Lightning Protection System (LPS) is installed on a building. Where partial lightning currents can also flow due to a direct lightning strike on overhead supplies or externally mounted equipment, Type 1 SPDs should also be used. Combined Type `1 + Type 2 SPDs are installed at the origin of the supply to the building, normally within the main switchboard. If the installation being protected is already fitted with an SCPD of 315A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected.In installations where it is not possible to fit a fuse or circuit breaker the ‘IF’ (Internal Fuse) version is available.

Type 2 SPDs in this modular form offer more general surge protection for equipment within the installation from sources of problematic electrical surges internal to the building (typically switching transients). If the installation being protected is already fitted with an SCPD of 125A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected. In installations where it is not possible

to fit a fuse or circuit breaker the ‘IF’ (Internal Fuse) version is available. Their protection is limited by distance with a general protection zone of <10m. Equipment further away necessitate the installation of an additional Type 2 units in sub-distribution boards.

Type 2 and Type 3 SPDs are designed to discharge the induced surges created by lightning electromagnetic fields and also other transient surge events such as switching surges, supply faults etc. These devices are defined as being tested with a specific energy wave shape of 8/20μs (In) for Type 2 SPDs or a combination wave shapes for Type 3 SPDs. For many applications where the requirement is to provide surge protection only, Type 2 and Type 3 SPDs play a critical role in protecting electronic equipment.

Type 3 SPDs provide the primary ‘fine protection’ from surges, giving high sensitive equipment that added level of security. As a rule they should be installed as close as possible to the equipment being protected.This class of product is available in both din-rail mounting version or remote/local installation. For example the SPD/T3/LPC can be wired into the back of a plug socket feeding a certain piece of equipment. The SPD/T3/LPC has also the benefit of an audible alarm, for when the unit requires replacing.

Technical Information

Tech

nica

l Inf

orm

atio

n

Standards:Operating voltage:Operating frequency:Ambient operating temp.:Maxi. terminal torque:Enclosure material:

Supply connections:IP rating:Dielectric voltage:Insulation voltage:

BSEN 61008 2P-230V a.c. 4P-230/400V a.c.50Hz-5°C - +40°C2.5Nm VO rated polyamide or PBT (both self extinguishing at 960°C)Consult specific product data sheetIP4X (front face); IP20 (terminals)2500V a.c.500V a.c.

General Specification

RCDs Proteus RCDs are available in a wide range of earth leakage sensitivities and current ratings to meet the majority of applications. Residual Current Devices (RCDs) come in both 2 pole and 4 pole options.

Proteus RCDs incorporate the latest in electronic earth leakage detection technology ensuring consistent reliable performance. With sufficient contact gap, switching of all Live and Neutral conductors and positive contact indication in accordance with the IEE wiring regulation these devices can be used for isolation purposes.

RCDs also incorporate ‘trip free mechanism’ technology and can be locked ON or OFF with suitable locking device (eg.DLPX1) without affecting the devices ability to offer protection under fault conditions.

General use RCDs for domestic single phase or light commercial three phase systems are required to be either Type AC or Type A. This type reference defines the nature of the earth leakage which the RCD is expected to detect and protect against.

Type AC: Tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Identified by the symbol:

Type A: Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.Identified by the symbol:

Surge Protection Devices

Page 88: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

86

Technical InformationTe

chni

cal I

nfor

mat

ion

MCCB Protection of Motor Circuits

MCCB Protection of Capacitor Circuits

Moulded case circuit breakers are not in themselves intended to afford close thermal protection on motor circuits. However, when used in tandem with any intrinsic motor overload device they provide an excellent alternative to the combined isolator and fuse arrangements. In this case the motor is protected by its own circuit breaker.In order to select the correct MCCB, consideration should be given to individual MCCB time/current characteristics (for full details please refer to works). This should only be undertaken in

Moulded Case Circuit Breakers

Moulded case circuit breakers are commonly applied to capacitor currents. However, due to high in-rush currents and harmonic content found in capacitor circuits, MCCBs should be rated > 1.5 times the current rating of the capacitor.

conjunction with information provided by the motor manufacturer as to starting current and duration. The motor protection table shown provides a guide to MCCB selection based on the start current and duration indicated and it must always be noted that the drive and motor loading will affect the motor run up time.(i) The figures shown are based on the assumption that the motor starting conditions are:Direct On-Line =7 x full load current for 5 seconds max.

It is recommended that the MCCB should be utilized as a main isolation/protection device to the capacitor bank. (i.e. occasional switching). Capacitors should be individually protected and switched by appropriately rated contactors.

Motor Rating (kW) Motor Rating (HP) Approx. FLC (A) at 400V Direct On Line MCCB Type/Current Rating

< 5.5 < 7.5 < 11.5 16A MC016T

< 11 < 15 < 22.5 25A MC025T

< 15 < 20 < 30 32A MC032T

< 18 < 25 < 36 40A MC040T

< 22 < 30 < 43 50A MC050T

< 30 < 40 < 58 63A MC063TMR

< 37 < 50 < 72 80A MC080TMR

< 45 < 60 < 83 100A MC100TMR

< 55 < 75 < 103 125A MC125TMR

< 80 < 110 < 147 160A MC160TMR

< 90 < 125 < 169 200A MC200TMR

< 110 < 150 < 205 250A MC250TMR

< 160 < 220 < 292 315A MC315T

< 200 < 270 < 368 400A MC400T

< 250 < 340 < 465 500A MC500T

< 315 < 430 < 580 630A MC630T

IEC Utilization Categories for Low Voltage Switchgear

The below table lists only categories applicable to BSEN60974-3 - Switches , Disconnectors, Switch-disconnectors and Fuse-combination units.

Current Category Typical Application

AC AC - 20 Connecting and disconnecting under no-load conditions

AC - 21 Switching of resistive loads including moderate overloads

AC - 22 Switching of mixed resistive and inductive loads, including moderate overloads

AC - 23 Switching of motor loads or other highly inductive loads

DC DC - 20 Connecting and disconnecting under no-load conditions

DC - 21 Switching of resistive loads including moderate overloads

DC - 22 Switching of mixed resistive and inductive loads, including moderate overloads

DC - 23 Switching of motor loads or other highly inductive loads

The letter A or B can be suffixed dependent on whether the intended application requires frequent (A) or infrequent (B) operation.[For full details consult the full chart in BSEN60947-1]

Page 89: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

87

PR

OTE

US

Tech

nica

l Inf

orm

atio

n

Ingress Protection (IP Rating)IEC/EN 60529 is an international set of test specification standards for classifying the degrees of protection provided by the enclosures of electrical equipment against the intrusion into the equipment of foreign bodies (i.e. tools, dust, fingers, etc) and moisture. This classification system utilizes the letters “IP” (“Ingress Protection”) followed by two or three digits. (A third digit is sometimes used. An “x” is used for one of the digits if there is only one class of protection; i.e. IPX4 which addresses moisture resistance only.)

Applicable StandardsThough not exhaustive the below table lists the British / European harmonised standards to which products in this catalogue comply (where applicable).

1st Digit Protection from solid objects 2nd Digit Protection from moisture1 Protected against solid object greater than

50mm1 Protection against vertically dripping water

2 Protected against solid object greater than 12.5mm

2 Protection against dripping water when tilted upto 15degrees

3 Protected against solid object greater than 2.5mm

3 Protection against spraying water

4 Protected against solid object greater than 1mm

4 Protection against splashing water

5 Dust protected 5 Protection against jetting water

6 Dust tight 6 Protection against powerfully jetting water

7 Protection against the temporary affects of immersion

8 Protection against continuous submersion

The first digit of the IP code indicates the degree that persons are protected against contact with moving parts (other than smooth rotating shafts, etc.) and the degree that equipment is protected against solid foreign bodies intruding into an enclosure.The second digit indicates the degree of protection of the equipment inside the enclosure against the harmful entry of various forms of moisture (e.g. dripping, spraying, submersion, etc.)[For full details consult IEC/EN60529]

Standard TitleBS88 Cartridge fuses for voltages up to and including 1000A a.c. and 1500V d.c.

BSEN60269 Low-voltage Fuses

BSEN61439 Low-voltage switchgear and controlgear assemblies

BSEN61439-2 Power switchgear and controlgear assemblies

BSEN61439-3 Distribution boards intended to be operated by ordinary persons (DBO)

BSEN60529 Specification for degree of protection provided by enclosures (IP code)

BSEN60898 Specification for circuit-breakers for overcurrent protection for household and similar installations

BSEN60947 Low-voltage switchgear and control gear

BSEN60947-2 Circuit-breakers

BSEN60947-3 Switches, disconnectors, switch-disconnectors and fuse-combination units

BSEN60947-4 Electromechanical contactors and motor starters

BSEN61008 Residual current operated circuit breakers without integral overcurrent protection for household and similar use (RCCBs / RCDs)

BSEN61009 Residual current operated circuit breakers with integral overcurrent protection for household and similar use (RCBOs)

BSEN61095 Specification for electromechanical contactors for household and similar purposes

Technical Information

Page 90: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

88

IndexIn

dex

1SCT .............................................761SCT/P .........................................766MBRSP .......................................506MBRSPK .....................................506MCRSP .......................................506MCRSPK .....................................506MRBE ..........................................5010MBRSP .....................................5010MBRSPK ...................................5010MCRSP .....................................5010MCRSPK ...................................5010MRBE ........................................5016MBRSP .....................................5016MBRSPK ...................................5016MCRSP .....................................5016MCRSPK ...................................5016MRBE ........................................5020MBRSP .....................................5020MBRSPK ...................................5020MCRSP .....................................5020MCRSPK ...................................5020MRBE ........................................5025/2/30T .......................................5125/2/100T .....................................5125/2/300T .....................................5125/2/500T .....................................5125/4/30* .......................................5125/4/100 .......................................5125/4/300 .......................................5125MBRSPK ...................................5025MCRSPK ...................................5032MBRSP .....................................5032MBRSPK ...................................5032MCRSP .....................................5032MCRSPK ...................................5032MRBE ........................................5040/2/30T .......................................5140/2/100T .....................................5140/2/300T .....................................5140/2/500T .....................................5140/4/30 .........................................5140/4/100 .......................................5140/4/300 .......................................5140MBRSP .....................................5040MCRSP .....................................5040MRBE ........................................5045MBRSP .....................................5045MBRSPK ...................................5045MCRSP .....................................5045MCRSPK ...................................5045S2 .............................................7745S3 .............................................7763/2/30T .......................................5163/2/100T .....................................51

63/2/300T .....................................5163/2/500T .....................................5163/4/30 .........................................5163/4/100 .......................................5163/4/300 .......................................5163S2 .............................................7763S3 .............................................7763S4 .............................................7766MBRSP .....................................5066MCRSP .....................................5071ST .............................................7672ST .............................................7680/2/30T .......................................5180/2/100T .....................................5180/2/300T .....................................5180/2/500T .....................................5180/4/30 .........................................5180/4/100 .......................................5180/4/300 .......................................51100/2/30T .....................................51100/2/100D ...................................51100/2/100T ...................................51100/2/300T ...................................51100/2/500T ...................................51100/4/30* .....................................51100/4/100 .....................................51100/4/300 .....................................51100BC2 ........................................44100BC3 ........................................44100BC4 ........................................44100BC6 ........................................44100S2 ...........................................77100S3 ...........................................77100S4 ...........................................77106MBRSP ...................................50106MCRSP ...................................50166MBRSP ...................................50166MCRSP ...................................50200BC2 ........................................44200BC3 ........................................44200BC4 ........................................44200BC6 ........................................44206MBRSP ...................................50206MCRSP ...................................50241S .............................................76241SQ ..........................................76242S .............................................76242SQ ..........................................76300BC2 ........................................44300BC3 ........................................44300BC4 ........................................44300BC6 ........................................44326MBRSP ...................................50326MCRSP ...................................50

400BC2 ........................................44400BC3 ........................................44400BC4 ........................................44400BC6 ........................................44406MBRSP ...................................50406MCRSP ...................................50600BC2 ........................................44600BC3 ........................................44600BC4 ........................................44600BC6 ........................................44601B .............................................49602B .............................................49604B .............................................49606B .............................................49606C .............................................49610B .............................................49610C .............................................49616B .............................................49616C .............................................49620B .............................................49620C .............................................49625B .............................................49625C .............................................49630FS ...........................................36632B .............................................49632C .............................................49640B .............................................49640C .............................................49645B .............................................49650B .............................................49650C .............................................49663B .............................................49663C .............................................49800BC3 ........................................44800BC4 ........................................44800BC6 ........................................44800FS ...........................................361002/2 ..........................................491002/3 ..........................................491004/3 ..........................................491006/2 ..........................................491006/4 ..........................................491010/2 ..........................................491010/4 ..........................................491016/2 ..........................................491016/4 ..........................................491020/2 ..........................................491020/4 ..........................................491032/2 ..........................................491032/4 ..........................................491040/2 ..........................................491040/4 ..........................................491050/2 ..........................................491050/4 ..........................................49

Page 91: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

89

PR

OTE

US

Inde

x

Index

1063/2 ..........................................491063/4 ..........................................493606C ...........................................493610C ...........................................493616C ...........................................493620C ...........................................493625C ...........................................493632C ...........................................493640C ...........................................493650C ...........................................493663C ...........................................4921006/3 ........................................4921010/3 ........................................4921016/3 ........................................4921020/3 ........................................4921032/3 ........................................4921040/3 ........................................4921050/3 ........................................4921063/3 ........................................4931002/3 ........................................4931004/3 ........................................4931006/2 ........................................4931006/3 ........................................4931006/4 ........................................4931010/2 ........................................4931010/3 ........................................4931010/4 ........................................4931016/2 ........................................4931016/3 ........................................4931016/4 ........................................4931020/2 ........................................4931020/3 ........................................4931020/4 ........................................4931025/3 ........................................4931032/2 ........................................4931032/3 ........................................4931032/4 ........................................4931040/2 ........................................4931040/3 ........................................4931040/4 ........................................4931050/2 ........................................4931050/3 ........................................4931050/4 ........................................4931063/2 ........................................4931063/3 ........................................4931063/4 ........................................4941006/3 ........................................4941010/3 ........................................4941016/3 ........................................4941020/3 ........................................4941032/3 ........................................4941040/3 ........................................4941050/3 ........................................4941063/3 ........................................49

AABX2R30V ....................................32ABX2R100V ..................................32ABX2R300V ..................................32ABX2S1 .........................................32ABX2S1V .......................................32ABX4R30V ....................................32ABX4R100V ..................................32ABX4R300V ..................................32ABX4S1 .........................................32ABX4S1V .......................................32ABX6R30V ....................................32ABX6R100V ..................................32ABX6R300V ..................................32ABX6S1 .........................................32ABX6S1V .......................................32ABX8R30V ....................................32ABX8R100V ..................................32ABX8R300V ..................................32ABX8S1 .........................................32ABX8S1V .......................................32ABX12R30V ..................................32ABX12R100V ................................32ABX12R300V ................................32ABX12S1 .......................................32ABX12S1V .....................................32AJBXM2U......................................61AJBXM4 ........................................61AJBXM4U......................................61AJBXM6 ........................................61AJBXM6U......................................61AJBXM8 ........................................61AJBXM8U......................................61AJBXM12 ......................................61AJBXM12U....................................61AKBXM2U .....................................61AKBXM4 ........................................61AKBXM4U .....................................61AKBXM6 ........................................61AKBXM6U .....................................61AKBXM8 ........................................61AKBXM8U .....................................61AKBXM12 ......................................61AKBXM12U ...................................61AKL ...............................................65ALBXM2U .....................................61ALBXM4 ........................................61ALBXM4U .....................................61ALBXM6 ........................................61ALBXM6U .....................................61ALBXM8 ........................................61ALBXM8U .....................................61ALBXM12 ......................................61ALBXM12U ...................................61

APGU2M .......................................64APGU4M .......................................64APGU4MU ....................................64APSU95M .....................................64APSU115M ...................................64APXLM6U ......................................64APXLM10U ....................................64APXLM12U ....................................64APXLM16U ....................................64APXLM18U ....................................64APXLM22U ....................................64APXLM28U ....................................64ASM10 ..........................................65ASM12 ..........................................65ASM16 ..........................................65ASM18 ..........................................65ASM22 ..........................................65ASM28 ..........................................65AX4 ...............................................33AX4MA ..........................................33AX4MD ..........................................33AX6 ...............................................33AX8 ...............................................33AX8MA ..........................................33AX8MD ..........................................33AX12 .............................................33AX12MA ........................................33AX12MD ........................................33AX16 .............................................33AX20 .............................................33AX26 .............................................33AYXLM1JB2JB3 ............................63AYXLM1JB2JB3U..........................63AYXLM2.........................................60AYXLM2JB4JB4 ............................63AYXLM2JB4JB4U..........................63AYXLM2JB5JB5 ............................63AYXLM2JB5JB5U..........................63AYXLM2JB6JB6 ............................63AYXLM2JB6JB6U..........................63AYXLM4.........................................60AYXLM4KB8KB8 ...........................63AYXLM4KB8KB8U .........................63AYXLM4U ......................................60AYXLM6.........................................60AYXLM6U ......................................60AYXLM6Y2U ..................................63AYXLM8.........................................60AYXLM8U ......................................60AYXLM8Y4U ..................................63AYXLM8Y6U ..................................63AYXLM10.......................................60AYXLM10U ....................................60AYXLM10Y4U ................................63

Page 92: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

90

IndexIn

dex

AYXLM10Y10U ..............................63AYXLM12.......................................60AYXLM12U ....................................60AYXLM12Y4U ................................63AYXLM12Y6U ................................63AYXLM14.......................................60AYXLM14U ....................................60AYXLM16.......................................60AYXLM16U ....................................60AYXLM18.......................................60AYXLM18U ....................................60AYXLM20.......................................60AYXLM20U ....................................60AYXLM26.......................................60AYXLM26U ....................................60AYXLM30* .....................................60AYXLMDSLV6 ................................63AYXLMDSLV6U .............................63AYXLMDSLV10 ..............................63AYXLMDSLV10U ...........................63AYXLMDSLV12 ..............................63AYXLMDSLV12U ...........................63AYXLMDSLV16 ..............................63AYXLMDSLV16U ...........................63AYXLMDSLV22 ..............................63AYXLMDSLV22U ...........................63AYXLME6 ......................................64AYXLME10 ....................................64AYXLME12 ....................................64AYXLME16 ....................................64AYXLME18 ....................................64AYXLME22 ....................................64AYXLME28 ....................................64AYXLMJB3JB3 ..............................62AYXLMJB3JB3U ............................62AYXLMJB3JB3Y2U........................63AYXLMJB4JB4Y4U........................63AYXLMJB5JB5 ..............................62AYXLMJB5JB5U ............................62AYXLMJB5JB5Y4U........................63AYXLMJB6JB6 ..............................62AYXLMJB6JB6U ............................62AYXLMJB8JB8 ..............................62AYXLMJB8JB8U ............................62AYXLMJB10JB10 ..........................62AYXLMJB10JB10U........................62AYXLMKB5KB5 .............................62AYXLMKB5KB5U ...........................62AYXLMKB6KB6 .............................62AYXLMKB6KB6U ...........................62AYXLMKB8KB8 .............................62AYXLMKB8KB8U ...........................62AYXLMKB10KB10 .........................62AYXLMKB10KB10U .......................62

AYXLMSLV6 ...................................62AYXLMSLV6U ................................62AYXLMSLV12 .................................62AYXLMSLV12U ..............................62

BB1 .................................................78BBS1 ............................................78BCC185/23 ...................................45BCC185/48 ...................................45BCC240/48 ...................................45BLC6/23 .......................................45BLC6/48 .......................................45BLC8/23 .......................................45BLC8/48 .......................................45BLC10/23 .....................................45BLC10/48 .....................................45BM1 ..............................................78BX4P30 .........................................29BX4Q30 ........................................29BX4R30 .........................................30BX4R100 .......................................30BX4R300 .................................29, 30BX4S2 ...........................................28BX4S125 .......................................28BX4S125TNS ................................53BX4S125TT ...................................53BX6P30 .........................................29BX6Q30 ........................................29BX6R30 .........................................30BX6R100 .......................................30BX6R300 .................................29, 30BX6S2 ...........................................28BX6S125 .......................................28BX6S125TNS ................................53BX6S125TT ...................................53BX8P30 .........................................29BX8Q30 ........................................29BX8R30 .........................................30BX8R100 .......................................30BX8R300 .......................................30BX8S2 ...........................................28BX8S125 .......................................28BX8S125TNS ................................53BX8S125TT ...................................53BX8S250 .......................................28BX12P30 .......................................29BX12Q30 ......................................29BX12R30 .......................................30BX12R100 .....................................30BX12R300 .....................................30BX12S2 .........................................28BX12S125 .....................................28BX12S125TNS ..............................53

BX12S125TT .................................53BX12S250 .....................................28BX16P30 .......................................29BX16Q30 ......................................29BX16R30 .......................................30BX16R100 .....................................30BX16R300 .....................................30BX16S2 .........................................28BX16S125 .....................................28BX16S125TNS ..............................53BX16S125TT .................................53BX16S250 .....................................28BX20P30 .......................................29BX20Q30 ......................................29BX20R30 .......................................30BX20R100 .....................................30BX20R300 .....................................30BX20S2 .........................................28BX20S125 .....................................28BX20S125TNS ..............................53BX20S125TT .................................53BX20S250 .....................................28BX24P30 .......................................29BX24Q30 ......................................29BX24R30 .......................................30BX24R100 .....................................30BX24R300 .....................................30BX24S2 .........................................28BX24S125 .....................................28BX24S125TNS ..............................53BX24S125TT .................................53BX24S250 .....................................28BXM14 ..........................................29BXM28 ..........................................29BXS2TNSK ....................................53BXS2TTK .......................................53BXSB1...........................................30BXSB2...........................................30BXSCK1 ........................................30BXSCK2 ........................................30

CCB7TP ..........................................78CB8DP ..........................................78CB12DP ........................................78CB12TP ........................................78CB19SP ........................................78CB28SP ........................................78CB080S/C .....................................25CB080T/C .....................................25CB100S/C .....................................25CB100T/C .....................................25CB125S/C .....................................25CB125T/C .....................................25

Page 93: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

91

PR

OTE

US

Inde

x

Index

CBC3 ............................................78CBCT1 ..........................................78CBENCSP .....................................25CBENCTP .....................................25CBX22I200 ..............................24, 25CBX22/I250 ...................................25CBX24I200 ..............................24, 25CBX24/I250 ...................................25CBX42I200 ..............................24, 25CBX42/I250 ...................................25CBX44I200 ..............................24, 25CBX44/I250 ...................................25CBX62I200 ..............................24, 25CBX62/I250 ...................................25CBX64I200 ..............................24, 25CBX64/I250 ...................................25CBX82I200 ..............................24, 25CBX82/I250 ...................................25CBX84I200 ..............................24, 25CBX84/I250 ...................................25CBX122I200 ............................24, 25CBX122/I250 .................................25CBX124I200 ............................24, 25CBX124/I250 .................................25CO/202 .........................................42CO/203 .........................................42CO/204 .........................................42CO/322 .........................................42CO/323 .........................................42CO/324 .........................................42CO/632 .........................................42CO/633 .........................................42CO/634 .........................................42CO/1002 .......................................42CO/1003 .......................................42CO/1004 .......................................42CT202 ...........................................77CT202NC ......................................77CT204 ...........................................77CT204NC ......................................77CT404 ...........................................77CT404NC ......................................77CT634 ...........................................77CT634NC ......................................77

DDLPX1 ...........................................78DLPX1P ........................................78

EE20TN ...........................................39E32TN ...........................................39E63TN ...........................................39

E100TN .........................................39E160TN .........................................39E200TN .........................................39EF20D ...........................................39EF20S ...........................................39EF20TN .........................................39EF32D ...........................................39EF32S ...........................................39EF32TN .........................................39EF63D ...........................................39EF63S ...........................................39EF63TN .........................................39EF100D .........................................39EF100S .........................................39EF100TN .......................................39EHC1 ............................................72EHC1L ..........................................72EHC3 ............................................72EMCB1NC ....................................47EMCB1NO ....................................47EMIS2 ECO ...................................72EMIS4 ECO ...................................72EMIS ECO .....................................72EMISN ...........................................72EM/STOP ......................................47ENC202 ........................................70ENC204 ........................................70ENC404 ........................................70ENC542 ........................................70ENC544 ........................................70ENC546 ........................................70ENC654 ........................................70ENC658 ........................................70ENC5410 ......................................70ENC5416 ......................................70ENC6512 ......................................70ENC6524 ......................................70ENC6536 ......................................70ETB5 .............................................72ETB5BL .........................................72ETB5BR ........................................72

FFS1 ...............................................73

GGBX1 ............................................69GBX2 ............................................69GBX3 ............................................69GBX4 ............................................69

HHBX1 ............................................69HBX2 ............................................69HBX3 ............................................69HBX4 ............................................69HBX6 ............................................69HLC25 ..........................................47HLC32 ..........................................47HLC63 ..........................................47HLC100 ........................................47HLC200 ........................................47

IIP65E302013 ................................46IP65E403022 ................................46IP65E504024 ................................46IP65E604020 ................................46IP65E705025 ................................46

JJBX1 .............................................69JBX2 .............................................69JBX3 .............................................69JBX4 .............................................69JBX6 .............................................69JBX8 .............................................69JBX10 ...........................................69JBX12 ...........................................69

KKBX4 .............................................69KBX6 .............................................69KBX8 .............................................69KBX10 ...........................................69KBX12 ...........................................69KWH2A .........................................27KWH2D .........................................27KWH2E .........................................27KWH4A .........................................27KWH4D .........................................27KWH4E .........................................27KWH45AMID .................................72KWH100AMID ...............................72

LLBX6 .............................................69LBX8 .............................................69LBX10 ...........................................69LBX12 ...........................................69

Page 94: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

92

IndexIn

dex

MM20T .............................................40M25T .............................................40M32T .............................................40M63T .............................................40M100T ...........................................40M160T ...........................................40M200T ...........................................40M204 .............................................40M206 .............................................40M254 .............................................40M324 .............................................40M326 .............................................40M634 .............................................40M636 .............................................40M1004 ...........................................40M1604 ...........................................40M2004 ...........................................40M3262 ...........................................40M6362 ...........................................40MC016S ........................................22MC016T ........................................22MC020S ........................................22MC020T ........................................22MC025S ........................................22MC025T ........................................22MC032S ........................................22MC032T ........................................22MC040S ........................................22MC040T ........................................22MC050S ........................................22MC050T ........................................22MC063FA ......................................23MC063S ........................................22MC063T ........................................22MC080S ........................................22MC080T ........................................22MC100F ........................................23MC100FA ......................................23MC100S ........................................22MC100T ........................................22MC125F ........................................23MC125FA ......................................23MC125S ........................................22MC125T ........................................22MC160F ........................................23MC160FA ......................................23MC160S ........................................22MC160T ........................................22MC200F ........................................23MC200FA ......................................23MC200S ........................................22MC200T ........................................22MC200TNA ...................................23

MC250F ........................................23MC250FA ......................................23MC250FALF ..................................23MC250FLF ....................................23MC250T ........................................22MC250TLF ....................................22MC250TNA ...................................23MC315F ........................................23MC315FA ......................................23MC315T ........................................22MC400F ........................................23MC400FA ......................................23MC400T ........................................22MC400TNA ...................................23MC500F ........................................23MC500FA ......................................23MC500T ........................................22MC630F ........................................23MC630FA ......................................23MC630T ........................................22MC630TNA ...................................23MC800F ........................................23MC800T ........................................22MC800TNA ...................................23MC1000T ......................................22MC1250T ......................................22MC1600T ......................................22MCCBM1 ......................................19MCE063F ......................................17MCE063T ......................................17MCE080F ......................................17MCE080T ......................................17MCE100F ......................................17MCE100T ......................................17MCE125F ......................................17MCE125T ......................................17MCE160F ......................................17MCE160T ......................................17MCE200F ......................................17MCE200T ......................................17MCE250F ......................................17MCE250T ......................................17MCE315F ......................................17MCE315T ......................................17MCE400F ......................................17MCE400T ......................................17MCE500F ......................................17MCE500T ......................................17MCE630F ......................................17MCE630T ......................................17MCE800F ......................................17MCE800T ......................................17MCEL100T ....................................17MCEL125T ....................................17

MCEL160T ....................................17MCEL200T ....................................17MCEL250T ....................................17MCEL315T ....................................17MCEL400T ....................................17MCEL500T ....................................17MCEL630T ....................................17MCENC1.......................................18MCENC1F ....................................18MCENC2.......................................18MCENC2F ....................................18MCENC6.......................................18MCENC6F ....................................18MCENC8.......................................18MCENC8F ....................................18MCLK120 ......................................19MCLK150 ......................................19MCLK185 ......................................19MCLTS ..........................................19MCNUTM8 ....................................19MCP32/I200 ..................................10MCP32/I250 ..................................10MCP42/I200F ................................10MCP42/I250F ................................10MCP44/I315 ..................................12MCP44/I315F ................................12MCP44/I400 ..................................12MCP44/I400F ................................12MCP48/I500 ..................................14MCP48/I500F ................................14MCP48/I630 ..................................14MCP48/I630F ................................14MCP48/I800 ..................................14MCP48/I800F ................................14MCP52/I200 ..................................10MCP52/I250 ..................................10MCP62/I200F ................................10MCP62/I250F ................................10MCP64/I315 ..................................12MCP64/I315F ................................12MCP64/I400 ..................................12MCP64/I400F ................................12MCP68/I500 ..................................14MCP68/I500F ................................14MCP68/I630 ..................................14MCP68/I630F ................................14MCP68/I800 ..................................14MCP68/I800F ................................14MCP72/I200 ..................................10MCP72/I250 ..................................10MCP82/I200F ................................10MCP82/I250F ................................10MCP84/I315 ..................................12MCP84/I315F ................................12

Page 95: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

93

PR

OTE

US

Inde

x

Index

MCP84/I400 ..................................12MCP84/I400F ................................12MCP88/I500 ..................................14MCP88/I500F ................................14MCP88/I630 ..................................14MCP88/I630F ................................14MCP88/I800 ..................................14MCP88/I800F ................................14MCP112/I200 ................................10MCP112/I250 ................................10MCP122/I200F ..............................10MCP122/I250F ..............................10MCP124/I315 ................................12MCP124/I315F ..............................12MCP124/I400 ................................12MCP124/I400F ..............................12MCP128/I500 ................................14MCP128/I500F ..............................14MCP128/I630 ................................14MCP128/I630F ..............................14MCP128/I800 ................................14MCP128/I800F ..............................14MCP152/I200 ................................10MCP152/I250 ................................10MCP162/I200F ..............................10MCP162/I250F ..............................10MCP164/I315 ................................12MCP164/I315F ..............................12MCP164/I400 ................................12MCP164/I400F ..............................12MCP168/I500 ................................14MCP168/I500F ..............................14MCP168/I630 ................................14MCP168/I630F ..............................14MCP168/I800 ................................14MCP168/I800F ..............................14MCP172/I200 ................................10MCP172/I250 ................................10MCP182/I200F ..............................10MCP182/I250F ..............................10MCP184/I315 ................................12MCP184/I315F ..............................12MCP184/I400 ................................12MCP184/I400F ..............................12MCP188/I500 ................................14MCP188/I500F ..............................14MCP188/I630 ................................14MCP188/I630F ..............................14MCP188/I800 ................................14MCP188/I800F ..............................14MCPBEB200 .....................11, 13, 15MCPBEB300 .....................11, 13, 15MCPCB22L .......................11, 13, 15MCPCB22R ......................11, 13, 15

MCPCB24L .......................11, 13, 15MCPCB24R ......................11, 13, 15MCPCB32L .......................11, 13, 15MCPCB32R ......................11, 13, 15MCPCB34L .......................11, 13, 15MCPCB34R ......................11, 13, 15MCPD ...........................................19MCPDMM063S .............................16MCPDMM063T .............................16MCPDMM100S .............................16MCPDMM100T .............................16MCPDMM125S .............................16MCPDMM125T .............................16MCPDMM160S .............................16MCPDMM160T .............................16MCPDMM200S .............................16MCPDMM200T .............................16MCPDMM250T .............................16MCPDMM315T .............................16MCPDMM400T .............................16MCPDMM500T .............................16MCPDMM630T .............................16MCPDMM800T .............................16MCPEB32L ...................................11MCPEB32R ...................................11MCPEB42FL .................................11MCPEB42FR .................................11MCPEB44L ...................................13MCPEB44R ...................................13MCPEB48R ...................................15MCPEB52L ...................................11MCPEB52R ...................................11MCPEB62FL .................................11MCPEB62FR .................................11MCPEB64L ...................................13MCPEB64R ...................................13MCPEB68R ...................................15MCPEB72L ...................................11MCPEB72R ...................................11MCPEB82FL .................................11MCPEB82FR .................................11MCPEB84L ...................................13MCPEB84R ...................................13MCPEB88R ...................................15MCPEB112L .................................11MCPEB112R .................................11MCPEB122FL ...............................11MCPEB122FR ...............................11MCPEB124L .................................13MCPEB124R .................................13MCPEB128R .................................15MCPEB152L .................................11MCPEB152R .................................11MCPEB162FL ...............................11

MCPEB162FR ...............................11MCPEB164L .................................13MCPEB164R .................................13MCPEB168R .................................15MCPEB172L .................................11MCPEB172R .................................11MCPEB182FL ...............................11MCPEB182FR ...............................11MCPEB184L .................................13MCPEB184R .................................13MCPEB188L .................................15MCPEB188R .................................15MCPEL100 ....................................17MCPEL125 ....................................17MCPEL160 ....................................17MCPEL200 ....................................17MCPEL250 ....................................17MCPEL400 ....................................17MCPEL630 ....................................17MCPID ..........................................19MCPKWH063S..............................16MCPKWH063SMID .......................16MCPKWH063T ..............................16MCPKWH063TMID .......................16MCPKWH100S..............................16MCPKWH100SMID .......................16MCPKWH100T ..............................16MCPKWH100TMID .......................16MCPKWH125S..............................16MCPKWH125SMID .......................16MCPKWH125T ..............................16MCPKWH125TMID .......................16MCPKWH160S..............................16MCPKWH160SMID .......................16MCPKWH160T ..............................16MCPKWH160TMID .......................16MCPKWH200S..............................16MCPKWH200SMID .......................16MCPKWH200T ..............................16MCPKWH200TMID .......................16MCPKWH250T ..............................16MCPKWH250TMID .......................16MCPKWH315TMID .......................16MCPKWH400TMID .......................16MCPKWH500TMID .......................16MCPKWH630TMID .......................16MCPKWH800TMID .......................16MCPMB32L ..................................11MCPMB32R ..................................11MCPMB42FL ................................11MCPMB42FR ................................11MCPMB44L ..................................13MCPMB44R ..................................13MCPMB48L ..................................15

Page 96: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

94

IndexIn

dex

MCPMB48R ..................................15MCPMB52L ..................................11MCPMB52R ..................................11MCPMB62FL ................................11MCPMB62FR ................................11MCPMB64L ..................................13MCPMB64R ..................................13MCPMB68L ..................................15MCPMB68R ..................................15MCPMB72L ..................................11MCPMB72R ..................................11MCPMB82FL ................................11MCPMB82FR ................................11MCPMB84L ..................................13MCPMB84R ..................................13MCPMB88L ..................................15MCPMB88R ..................................15MCPMB112L ................................11MCPMB112R ................................11MCPMB122FL ..............................11MCPMB122FR ..............................11MCPMB124L ................................13MCPMB124R ................................13MCPMB128L ................................15MCPMB128R ................................15MCPMB152L ................................11MCPMB152R ................................11MCPMB162FL ..............................11MCPMB162FR ..............................11MCPMB164L ................................13MCPMB164R ................................13MCPMB168L ................................15MCPMB168R ................................15MCPMB172L ................................11MCPMB172R ................................11MCPMB182FL ..............................11MCPMB182FR ..............................11MCPMB184L ................................13MCPMB184R ................................13MCPMB188L ................................15MCPMB188R ................................15MCPMFM315T ..............................16MCPMFM400T ..............................16MCPMFM500T ..............................16MCPMFM630T ..............................16MCPMFM800T ..............................16MCPT2/TNSIF ...............................18MCPT2/TTIF ..................................18MCPT12/TNS ................................18MCPT12/TNSIF .............................18MCPT12/TT ...................................18MCPT12/TTIF ................................18MCST3P250 .................................18MCST3P630 .................................18

MCST3P800 .................................18MCST4P100 .................................18MCST4P400 .................................18MCST4P630 .................................18MCST4P800 .................................18MCX22/I200 ..................................24MCX22/I250 ..................................24MCX24/I200 ..................................24MCX24/I250 ..................................24MCX42/I200 ..................................24MCX42/I250 ..................................24MCX44/I200 ..................................24MCX44/I250 ..................................24MCX62/I200 ..................................24MCX62/I250 ..................................24MCX64/I200 ..................................24MCX64/I250 ..................................24MCX82/I200 ..................................24MCX82/I250 ..................................24MCX84/I200 ..................................24MCX84/I250 ..................................24MCX122/I200 ................................24MCX122/I250 ................................24MCX124/I200 ................................24MCX124/I250 ................................24MEMI .............................................47MEMK ...........................................47MEMSS .........................................47MEMT ...........................................47MTGP32B .....................................65MTGP32P .....................................65MTGP40B .....................................65MTGP40P .....................................65MTGPR40/32 ................................65

PPC020230V ...................................47PC025230V ...................................47PC032230V ...................................47PC063230V ...................................47PC100230V ...................................47PC200230V ...................................47PCB1NC .......................................47PCB1NO .......................................47PCS-11 .........................................47PDU4S ..........................................34PDU4S2 ........................................34PDU4S2S ......................................34PDU4SS ........................................34PDU6S ..........................................34PDU6S2 ........................................34PDU6S2S ......................................34PDU6SS ........................................34PDU8S ..........................................34

PDU8S2 ........................................34PDU8S2S ......................................34PDU8SS ........................................34PDU12S ........................................34PDU12S2S ....................................34PDU12SS ......................................34PDU16S ........................................34PDU16S2S ....................................34PDU16SS ......................................34PEB4 .............................................48PEB4/800 ......................................48PEB6 .............................................48PEB6/800 ......................................48PEB8 .............................................48PEB8/800 ......................................48PEB12 ...........................................48PEB12/800 ....................................48PEBTL6 .........................................48PEBTL6/800 ..................................48PEBTL8 .........................................48PEBTL8/800 ..................................48PEBTL12 .......................................48PEBTL12/800 ................................48PES20 ...........................................79PES32 ...........................................79PES40 ...........................................79PES50 ...........................................79PES63 ...........................................79PMS20 ..........................................79PMS32 ..........................................79PMS40 ..........................................79PMS50 ..........................................79PMS63 ..........................................79PMS80 ..........................................79PMS100 ........................................79PXL4 .............................................70PXL6 .............................................70PXL10 ...........................................70PXL16 ...........................................70PXL18 ...........................................70PXL20 ...........................................70PXL25 ...........................................70PXL32 ...........................................70PXS63 ...........................................79PXS80 ...........................................79PXS100 .........................................79

SSF20 .............................................73SF32 .............................................73SF40 .............................................73SF50 .............................................73SF63 .............................................73SF100 ...........................................73

Page 97: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

95

PR

OTE

US

Inde

x

Index

SF100/80 ......................................73SK2JB4JB4 ...................................81SK3JB7 .........................................81SK4JB6 .........................................81SK5JB5 .........................................81SK6JB4 .........................................81SK7JB3 .........................................81SKJB4JB4 .....................................81SKJB5JB5 .....................................81SKSLV6R4 .....................................81SKSLV12 .......................................81SPD/T1/TN ....................................52SPD/T1/TNE .................................52SPD/T1/TT ....................................52SPD/T1/TTE ..................................52SPD/T2/SP ....................................52SPD/T2/SPE ..................................52SPD/T2/TN ....................................52SPD/T2/TNE .................................52SPD/T2/TNS4P .............................52SPD/T2/TNS4PE ...........................52SPD/T2/TNS4PEF .........................53SPD/T2/TNS4PES .........................53SPD/T2/TNS4PIF ..........................52SPD/T2/TT ....................................52SPD/T2/TT4P ................................52SPD/T2/TT4PE ..............................52SPD/T2/TT4PEF ............................53SPD/T2/TT4PES ............................53SPD/T2/TT4PIF .............................52SPD/T2/TTE ..................................52SPD/T3/LPC .................................52SPD/T3/PC ...................................52SPD/T3/PCE .................................52SPD/T3/SC ...................................52SPD/T3/SCE .................................52SPD/T12/TNS4P ...........................52SPD/T12/TNS4PE .........................52SPD/T12/TNS4PEF .......................53SPD/T12/TNS4PES .......................53SPD/T12/TNS4PIF ........................52SPD/T12/TT4P ..............................52SPD/T12/TT4PE ............................52SPD/T12/TT4PEF ..........................53SPD/T12/TT4PES ..........................53SPD/T12/TT4PIF ...........................52

TTB5 ...............................................79TB8 ...............................................79TB10 .............................................79TB12 .............................................79TB14 .............................................79TB16 .............................................79

TCO202 ........................................42TCO203 ........................................42TCO204 ........................................42TCO322 ........................................42TCO323 ........................................42TCO324 ........................................42TCO632 ........................................42TCO633 ........................................42TCO634 ........................................42TCO1004 ......................................42TCO1254 ......................................42TCO1604 ......................................42TCO2004 ......................................42TCO2504 ......................................42TCO3154 ......................................42TCO4004 ......................................42TCO6304 ......................................42TCO8004 ......................................42TPS30 ...........................................73TPXIC1 ..........................................74TPXIC2 .........................................74TPXIC3 .........................................74TPXIC4 .........................................74TPXIPC1 ........................................74TPXIPC2 ........................................74TPXIPC3 ........................................74TPXIPC4 ........................................74TPXMC1 ........................................74TPXMC2 ........................................74TPXMC3 ........................................74TS20T ...........................................38TS32T ...........................................38TS63T ...........................................38TS100T .........................................38TS125T .........................................38TS160T .........................................38TS200T .........................................38TSF20T .........................................38TSF32T .........................................38TSF63T .........................................38TSF100T .......................................38TSF160T .......................................38

UU63FS ...........................................36U63S .............................................37U100FS .........................................36U100S ...........................................37U125FS .........................................36U125S ...........................................37U160FS .........................................36U160S ...........................................37U200FS .........................................36U200S ...........................................37

U250FS .........................................36U250S ...........................................37U315FS .........................................36U315S ...........................................37U400FS .........................................36U400S ...........................................37U500FS .........................................36U500S ...........................................37U630S ...........................................37UCB1 ............................................37UCB2 ............................................37UCB4 ............................................37

WWFS63/IP65 ..................................35WFS63/IP65SS..............................35WFS100/IP65 ................................35WFS100/IP65SS............................35WFS125/IP65 ................................35WFS125/IP65SS............................35WFS160/IP65 ................................35WFS160/IP65SS............................35WFS200/IP65 ................................35WFS200/IP65SS............................35WSF20/IP65 ..................................35WSF20/IP65SS..............................35WSF32/IP65 ..................................35WSF32/IP65SS..............................35WSF63/IP65 ..................................35WSF63/IP65SS..............................35WSF100/IP65 ................................35WSF100/IP65SS............................35

XXL4S1MA ......................................27XL4S1MD ......................................27XL4S2 ...........................................26XL4S125 .......................................26XL4S125TNS.................................53XL4S125TT ...................................53XL6BR ...........................................50XL6CR...........................................50XL6S1MA ......................................27XL6S1MD ......................................27XL6S2 ...........................................26XL6S125 .......................................26XL6S125TNS.................................53XL6S125TT ...................................53XL8S1MA ......................................27XL8S1MD ......................................27XL8S2 ...........................................26XL8S125 .......................................26XL8S125TNS.................................53

Page 98: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

96

IndexIn

dex

XL8S125TT ...................................53XL10BR .........................................50XL10CR.........................................50XL12S1MA ....................................27XL12S1MD ....................................27XL12S2 .........................................26XL12S125 .....................................26XL12S125TNS...............................53XL12S125TT .................................53XL16BR .........................................50XL16CR.........................................50XL16S1MA ....................................27XL16S1MD ....................................27XL16S2 .........................................26XL16S125 .....................................26XL16S125TNS...............................53XL16S125TT .................................53XL20BR .........................................50XL20CR.........................................50XL20S2 .........................................26XL20S125 .....................................26XL20S125TNS...............................53XL20S125TT .................................53XL24S2 .........................................26XL24S125 .....................................26XL24S125TNS...............................53XL24S125TT .................................53XL25CR.........................................50XL32BR .........................................50XL32CR.........................................50XL40BR .........................................50XL40CR.........................................50XL45BR .........................................50XL45CR.........................................50XL46MA ........................................27XL46MD ........................................27XL46SL .........................................26XL48SL .........................................26XL64SL .........................................26XL66SL .........................................26XL68MA ........................................27XL68MD ........................................27XL84SL .........................................26XL812MA ......................................27XL812MD ......................................27XLI100 ...........................................27XLI125 ...........................................27XLI200 ...........................................27XLKL .......................................26, 30XLS2TNSK ....................................53XLS2TTK .......................................53

YYXL1 .............................................68YXL2 .............................................68YXL3 .............................................68YXL4 .............................................68YXL6 .............................................68YXL8 .............................................68YXL12 ...........................................68YXL14 ...........................................68YXL16 ...........................................68YXL18 ...........................................68YXL21 ...........................................68YXL23 ...........................................68YXL30 ...........................................68

Page 99: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

VISIT OUR WEBSITE

ACCESS TO ALL OUR PRODUCTS.

CATALOGUE & DATA SHEET DOWNLOADS.

FOLLOW US ON SOCIAL MEDIA.

WWW.PROTEUSSWITCHGEAR.CO.UK

Page 100: LV Switchgear Distribution Boards Consumer Unitsproteusswitchgear.com/media/wysiwyg/MP 247 Proteus... · Custom Built LV Systems With increasing emphasis on energy conservation, Custom

Issue 4.3

The content of this catalogue is for information only. The manufacturer reserves the right to alter design or

specification without prior notice.

Colours are reproduced as accurately as photographic and printing processes allow and may not exactly

match the actual products.

Proteus Industrial

01952 292 [email protected]

Stafford Park 12Telford

ShropshireTF3 3BJ

Proteus Consumer