LV phase rotation tester
-
Upload
al-buraq-hardware-tools-llc -
Category
Technology
-
view
148 -
download
3
description
Transcript of LV phase rotation tester
![Page 1: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/1.jpg)
LV Phase rotation Indicator DR 706
![Page 2: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/2.jpg)
LV Phase rotation Indicator DR 706
Ergonomically shaped to fit comfortably in the palm
Replaceable leads with European colour codes and L1/L2/L3 marking (other markings or colours available).Probes with HPC fuses : Ø 4 mm – IP2X
Heavy duty waterproof housingIP65 housing protectionCircuit totally sealed with compound
Unique bright LED displayChasing GREEN LEDs for the clockwise rotation.Chasing RED LEDs for the counter-clockwise rotation.
![Page 3: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/3.jpg)
■ Functions of the LV Phase rotationTester
LV Phase rotation Indicator DR 706
3 phase indicators L1, L2 and L3
Clockwise rotation anti clockwise rotation
Unique display with bright Chasing LEDs
![Page 4: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/4.jpg)
■ Specification of the Phase rotation Indicator
LV Phase rotation Indicator DR 706
Voltage range : 80V to 400 V AC AC frequency range : 50 Hz & 60 Hz Maximum rated voltage : 440 V three
phase system Category of use : cat. IV (network) Class : N = - 10°C to + 55°C
■ Standard and Environment
Category of use : cat. IV (network) Probes with HPC fuses : Ø 4 mm –IP2X Protection : IP65 housing and circuit
totally sealed with compound
![Page 5: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/5.jpg)
All our products help utilities to face global challenges providing high safety level for electrical network improvement operations:Preparation / safetyEfficiency / Availability
THE NETWORK WILL CHANGE !
![Page 6: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/6.jpg)
THE NETWORK WILL CHANGE !
![Page 7: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/7.jpg)
THE NETWORK WILL CHANGE !
![Page 8: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/8.jpg)
Work in total confidence
with your powernetwork
![Page 9: LV phase rotation tester](https://reader036.fdocuments.in/reader036/viewer/2022062303/558e70521a28ab66638b4626/html5/thumbnails/9.jpg)
HISTORY & FIGURES
1949: creation of the company to supply earthing devices to “compagnie du Rhin”
1960: creation of the French LiveW competence Center (SERECT) in Mulhouse
1989: building of this building specialy designed around high voltage laboratory
1998: integration in Novarc Group 4800 m², 3500 references, TOP80% 1500 ref / 40 products 330 suppliers, 2M components, 200k end products ISO 9002 in 1996, ISO 9001 since 2002 Export rate > 65% in more than 100 countries