Luigi Papetti
Hydropower plantsLessons learnt, rehabilitation, failure analysis, repair
STUDIO FROSIO
Via P. F. Calvi, 9 - 25123 Brescia - I
![Page 2: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/2.jpg)
Why hydro and small hydro?
43%
31%
55%
13%
Source: GSE
![Page 3: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/3.jpg)
Why hydro and small hydro?
Hydroelectric output
[% total Italian hydro]
Hydroelectric production
[% total Italian hydro]
Source: GSE
![Page 4: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/4.jpg)
Plan of the lecture
1. High head – low head: short overview of the different main problems
2. Lesson learnt and field of action in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about failure
4. Failure analysis: what can go wrong in a plant.
5. Technical lesson learnt
6. Operational lesson learnt
![Page 5: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/5.jpg)
Output = k · head · flow rate
High head – low head: short overview of the different main problems
QHP ⋅⋅⋅= γη
![Page 6: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/6.jpg)
6
High head ⇒ small flow rate
High head – low head: short overview of the different main problems
Hg=466 m – Q=0,780 m3/s – P =2,8 MW Waterways
![Page 7: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/7.jpg)
7
Low head ⇒ large flow rate
High head –low head: short overview of the different main problems
Hg=6,5 m – Q=60 m3/s – P =3,0 MW Waterways
![Page 8: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/8.jpg)
8
Low head ⇒ large flow rate
High head – low head: short overview of the different main problems
Forebay and powerhouse
![Page 9: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/9.jpg)
9
High head ⇒ small flow rate
High head – low head: short overview of the different main problems
Powerhouse
![Page 10: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/10.jpg)
10
High head ⇒ small flow rate
High head – low head: short overview of the different main problems
Machinery
![Page 11: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/11.jpg)
11
Low head ⇒ large flow rate
High head – low head: short overview of the different main problems
Machinery
![Page 12: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/12.jpg)
12
High head
☺ Economically more favourable
�Far from cities and towns (access roads needed)
� Far from consumption points (electric lines needed)
Low head
☺ Wide spread all over the world
☺More suited to multi-purpose schemes
� Economically less favourable
High head – low head: short overview of the different main problems
![Page 13: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/13.jpg)
13
1. High head – low head: short overview of the different main problems
2. Lesson learnt and field of action in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about failure
4. Failure analysis: what can go wrong in a plant.
5. Technical lesson learnt
6. Operational lesson learnt
![Page 14: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/14.jpg)
14
Lesson learnt and field of action
![Page 15: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/15.jpg)
15
1. High head – low head: short overview of the different main problems
2. Lesson learnt in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about a failure
4. Failure analysis: what can go wrong in a plant.
5. Technical lesson learnt
6. Operational lesson learnt
7. Project management of a refurbishment: control of time, costs and final results: what’s more important?
8. Guide on how to refurbish a low head small hydroelectric plant
![Page 16: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/16.jpg)
16
Difficulty in collecting information about failure
![Page 17: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/17.jpg)
17
SCADA: Old models
Modern tools: SCADA (Supervisory Control And Data Acquisition)
Difficulty in collecting information about failure
![Page 18: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/18.jpg)
18
SCADA: new models
Difficulty in collecting information about failure
![Page 19: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/19.jpg)
19
1. High head – low head: short overview of the different main problems
2. Lesson learnt in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about failure
4. Failure analysis: what can go wrong in a plant
5. Technical lesson learnt
6. Operational lesson learnt
7. Project management of a refurbishment: control of time, costs and final results: what’s more important?
8. Guide on how to refurbish a low head small hydroelectric plant
![Page 20: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/20.jpg)
20
•original design or construction sins
•degradation of the performances due to age
•incorrect operation
Failure analysis: what can go wrong in a plant
![Page 21: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/21.jpg)
21
Typical problem:
STUDIO FROSIO
Sand/gravel deposition problems
Failure analysis: what can go wrong in a plant
![Page 22: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/22.jpg)
22
Cause - original sin - intake in the inner side of a river bendFailure analysis: what can go wrong in a plant
![Page 23: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/23.jpg)
23
Typical problem:
Runner blades erosion
Failure analysis: what can go wrong in a plant
![Page 24: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/24.jpg)
24
Cause - Degradation due to age – unit in operation since 1922
Failure analysis: what can go wrong in a plant
![Page 25: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/25.jpg)
25
Cause – incorrect operation and maintenance of the air vent at the inlet of the penstock
Typical problem:
Penstock failure due to internal depression
Failure analysis: what can go wrong in a plant
![Page 26: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/26.jpg)
26
Incorrect operation
Degradation due to age
Original sin
THE REALITY IS:
Failure analysis: what can go wrong in a plant
![Page 27: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/27.jpg)
Plan of the lecture
1. High head – low head: short overview of the different main problems
2. Lesson learnt in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about failure
4. Failure analysis: what can go wrong in a plant.
5. Technical lessons learnt
6. Operational lesson learnt
![Page 28: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/28.jpg)
Weirs and dams: flood managementUrago d’Oglio PlantLocation: Northern ItalyOglio River BasinQmax= 32 m3/sHg = 6,35 mRated output = 1,5 MW
•Old weir12 sliding gates 3,10 m span each37,2 m total width with 11 intermediate steel piers
Low flow situation
Medium flow situation
![Page 29: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/29.jpg)
Flood situation
Weirs and dams: flood management
![Page 30: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/30.jpg)
Weirs and dams: flood management
Effects of the small span of each gate
and side effects…Hang washing in boots...
![Page 31: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/31.jpg)
Weirs and dams: flood management
Solution
Basic constraints: it must be guaranteed that:
1.Gates lower in any situation
a) flood
2.Gates raise in any situation
a) obligations connected to irrigation system upstream
3.Accurate upstream water level regulation
a) obligations connected to irrigation system upstream
b) optimisation of the plant energy production
c) compliance with the requirements of limiting the diverted water at the
maximum amount allowed by water concession rights
![Page 32: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/32.jpg)
Weirs and dams: flood management
Solution
3 flap gates 11,50 m width Hydraulically operated
![Page 33: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/33.jpg)
Weirs and dams: flood managementSolution
Backup diesel generator for emergency operation
Lowering guaranteed by a mechanical system even in case of complete blackout condition
![Page 34: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/34.jpg)
Weirs and dams: flood management
Solution
Heavy flood during construction – no inundation upstream
![Page 35: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/35.jpg)
Weirs and dams: flood management
� expensive solution
� works in the river subject to contingencies (provisional dykes
destroyed by floods three times)
� special foundations needed due to concentrated loads coming
from hydraulic cylinders
☺ high discharging efficiency during floods
☺ high safety of operation
☺ precision in water level regulation
Pros and cons
![Page 36: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/36.jpg)
36
High head - conventional Tyrolean vs. Coanda
Maroggia plant – Northern Italy – Adda River Basin
Qmax = 0,2 m3/s
Hg = 716 m
P = 1.300 kW
Altitude of intake ~ 1.300 m.a.s.l.
Intakes
![Page 37: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/37.jpg)
37
What’s wrong?
•Bars too wide•Diagonal layout•Void ratio too low•Screen not inclined enough
Intakes
![Page 38: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/38.jpg)
38
Typical design of a Tyrolean intake Intakes
ψµ ⋅⋅= 01848,1
eL
e0=specific energy of the incoming flowµ=discharge coefficient~ broad crested weir ~ 0,4
ψ= ratio of opening area to the total area of the screen
L=length of the screen
![Page 39: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/39.jpg)
Subcritical flow
Supercritical flow
39
Typical design of a Tyrolean intake Intakes
Why 1,1848?
u2= ratio of the flow rate per unit width at the end of the screen to the maximum flow rate per unit width with e0; u2= 0 in case of total withdrawal
u1= ratio of the flow rate per unit width at the beginning of the screen to the maximum flow rate per unit width with e0 ; u1= 1 in case of critical flow at the beginning of the screen
![Page 40: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/40.jpg)
40
Solution: Coanda effect screenIntakes
Coanda effect screen: the tendency of a fluid jet to remain attached to a solid flow boundary.
![Page 41: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/41.jpg)
41
Solution: Coanda effect screenIntakes
Screen geometry and control volume Velocity vector approaching tilte-wire screen
![Page 42: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/42.jpg)
42
Solution: Coanda effect screen
���� very expensive (6-10 times a conventional screen)���� low resistance to boulders (protection with a coarse screen)☺☺☺☺ high diversion efficiency☺☺☺☺ excellent fine sediment exclusion (up to 0,5 mm)☺☺☺☺ no maintenance or loss of water for flushing sediments���� loss of head (high inclination)
Intakes
![Page 43: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/43.jpg)
43
Coanda screen – hydraulic computation
Reference: http://www.usbr.gov/pmts/hydraulics_lab/twahl/index.cfm
Intakes
![Page 44: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/44.jpg)
44
Sand/gravel deposition problems
Megolo PlantLocation: Northern ItalyToce River BasinQmax= 75 m3/sHg = 12,87 mRated output = 8 MW
IntakesLow head: importance of position and shape for sediment management
Desilting gate too small
![Page 45: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/45.jpg)
45
What’s wrong
Original sin - intake in the inner side of a river bend
Desilting gate too small:6 m over a 110 m wide weir
Intakes
Too low slope of the river
![Page 46: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/46.jpg)
46
21 m wider desilting span
SolutionIntakes
![Page 47: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/47.jpg)
47
Submerged longitudinal wall to concentrate flow lines
SolutionIntakes
![Page 48: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/48.jpg)
48
Solution
Abstraction of sand and gravel deposited to reshape the intake
Before After
Intakes
![Page 49: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/49.jpg)
49
Low head: importance of position and shape for sediment management
Original sin - intake in the inner side of a river bend
Pontey 1 PlantLocation: Northern ItalyDora Baltea River BasinQmax= 34,7 m3/sHg = 3,70 mRated output = 870 kW
Intakes
![Page 50: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/50.jpg)
50
Problem (unsolved): sediments at intake
Possible solutions:•Modification of rules of operation increasing flushing frequency (?)•Groins?
Intakes
![Page 51: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/51.jpg)
51
Typical problem:Leakages; hydraulic performance decrease
Channels
Headrace channels: reduction of sliding and stability problems
Prevalle-Chiese PlantLocation: Northern ItalyOglio River Basin (Chiese sub-basin)Qmax= 16 m3/sHg = 7,97mRated output = 1 MW
![Page 52: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/52.jpg)
52
Typical problem:Leakages; hydraulic performance decrease
Channels
![Page 53: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/53.jpg)
53
Typical problem:Leakages; hydraulic performance decrease
Channels
![Page 54: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/54.jpg)
54
Solution: total reconstruction
Channels
![Page 55: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/55.jpg)
55
Trapezoid cross section
Rectangular self-bearing cross section
Channels
65,1_0
_0 ≈trap
rect
Q
QIf b=h
40,1_0
_0 ≈trap
rect
Q
QIf b=2h
![Page 56: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/56.jpg)
56
Channels - Underpressure
![Page 57: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/57.jpg)
57
Channels - UnderpressureSolution: clapet valves
![Page 58: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/58.jpg)
58
Channels - UnderpressureSolution: clapet valves
![Page 59: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/59.jpg)
59
Penstocks: materials and layoutPenstocks
Allein PlantLocation: Northern ItalyDora Baltea River BasinQmax= 3,0 m3/sHg = 91 mRated output = 2,4 MW
Penstock replacement
Existing: asbestos
Interred?
Open air?
![Page 60: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/60.jpg)
60
Steel with spherical joints☺Commercial product; easy to assembly and weld; no inner pressure limitation
� Corrosion problems (it must be protected by an efficient coating system)
�Low resistance to external loads
☺ Easy to handle, no corrosion problem
☺ Excellent hydraulic behaviour (low head losses)
� Limits to inner pressure and external loads
� Bends more than 3-5° require special parts
☺ Good resistance to corrosion; high resistance to external loads
� Difficult to handle and to adapt to local conditions (every bend requires a special
part)
Cast iron
Plastics (GRP; HDPE; PVC)
Interred?
Penstocks
![Page 61: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/61.jpg)
61
Steel with chamfered edges☺ The whole pipe can be inssected, checked, maintained
☺ Well known technology world wide
� Corrosion problems (it must be protected by an efficient coating system)
� Visual impact
☺ Easy to handle, no corrosion problem
☺ Excellent hydraulic behaviour (low head losses)
� Expensive civil works (many saddle at small span)
� Joints critical
� Not usual
� Limitations to inner pressure because of the high thckness of the pipe wall for high
pressure
� Lower resilience at low temperatures if compared with steel
� Difficult to handle and to adapt to local conditions (every bend requires a special part)
Cast iron
Plastics (GRP)
Open air?
Penstocks
![Page 62: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/62.jpg)
62
Reasons
☺ Uncertainties in the final profile (probably need for
adaptation on site during works)
☺ No visual impact
� Need for cathodic protection (interference with an oil
pipeline
The winner is…Interred steel penstock with spherical joints
Penstocks
![Page 63: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/63.jpg)
63
Final resultPenstocks
![Page 64: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/64.jpg)
64
When shifting from horizontal to vertical shaft is not only a matter of a 90° turning
Tombetta 1 Plant
Location: Northern Italy
Adige River
Hg = 10,5 m
Qmax = 4 x 15 m3/s
P = 4 x 1.450 kW
Past situation: 4 Francis open flume in operation since 1922
Turbine pit
Machines hall before replacement
Units replacement
![Page 65: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/65.jpg)
65
Units replacement
Francis open flume Kaplan conventional single regulated
Alternatives
![Page 66: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/66.jpg)
66
Final choice: Vertical EcoBulb® turbinesUnits replacement
Double regulated vertical bulb turbines
![Page 67: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/67.jpg)
67
Final choice: Vertical EcoBulb® turbines
Units replacement
☺ High efficiency even at partial loads (double regulated
turbine)
☺ Few civil works to fit the new units to the existing
powerhouse
� Expensive
� No vertical units already installed (prototype) – Only
horizontal units installed
� Draft tube replacement required (works below tailwater
level)
![Page 68: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/68.jpg)
68
Units replacement
Units during erection
Pressurised bulbPermanent Magnets Generator
Powerhouse now
HPUs and compressors only
![Page 69: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/69.jpg)
69
Units replacement
Rendement pales bloquées de 0° à 13,2°
0,800
0,850
0,900
0,950
1,000
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600
puissance (kW)
rend
emen
t
8,00
9,00
10,00
11,00
12,00
Rendement total chute nette m
Results of efficiency tests
![Page 70: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/70.jpg)
70
Units replacementLESSON LEARNT
1. Problems with shaft seals (partially solved)2. Problems with compressors (solved)3. Accurate hydraulic modelling required for flow in the pit with formation
of stationary vortexes (solved)
LESSON: even for primary manufacturers, shifting from horizontal to vertical shaft is not only a matter of a 90° turning . Mechanical and hydraulic problems must be expected, faced in advance (possibly) and, in any case, solved, at the end.
![Page 71: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/71.jpg)
71
Transient phenomena
Prato Mele Plant
Location: Northern Italy
Serio River (Adda RB)
Hg = 10,5 m
Qmax = 3 x 4,3 m3/s
Refurbishment:
1. Replacement of 3 old Francis open flume with 3 sub-vertical bulb turbines
2. Headrace channel repairs
3. Substitution of intake gates
4. New TRCM
![Page 72: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/72.jpg)
72
Units replacement
Alternative 1ηw = 82,1 %
Existing
![Page 73: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/73.jpg)
73
Units replacement
ηw = 85,55 %
Alternative 2
ηw = 78,2 %
Alternative 3
![Page 74: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/74.jpg)
74
Units replacement
Final choice: alternative 3
☺ Minimum impact on the existing building
☺Minimum works below tailwater level
☺Best fitting to actual powerhouse layout
☺ Minimum risk of contingencies
� Low efficiency of units
![Page 75: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/75.jpg)
75
Transient phenomena
Units trip at rated discharge!!
LESSON LEARNT
![Page 76: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/76.jpg)
76
Transient phenomena
QLzA
zLz
L
AgV m
m
m
∆=⋅⋅
⋅⋅+⋅+⋅−
0
20
0 22
3
∆Q = flow rate variation in the channel
A0 = wetted area before the wave
V0 = flow velocity before the wave
Lm = channel width
Height z of the wave surge
![Page 77: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/77.jpg)
77
Transient phenomena
( ) ( ) ( ) ( ) ( ) ( )
( ) ( ) ( )( )
( ) ( ) ( ) ( ) ( ) ( )0
2
11
4
3111
8
11
*28
1*2
2
18
11
8
11
4
311
2
2
222
=+⋅⋅+⋅+
−⋅+⋅−⋅++⋅−⋅++
⋅−++⋅⋅−+⋅+⋅⋅⋅−
−+⋅−⋅−+⋅−+
−⋅+⋅−⋅
ififiiffif
ififififm
sf
ffiiffiiif
yyyyAyyAyyAyy
cyyyycyyyyAL
L
yyyyyyyyyy
µ
Action to reduce the height of the wave: lateral spillway at theforebay in front of the turbines
yi = ratio of wave height (measured from the bottom of the channel) at the beginning of the spillway to the depth h0 before transient
yf = ratio of wave height (measured from the bottom of the channel) at the end of the spillway to the depth h0 before transient
c* = ratio of the spillway height to the depth h0 before transient
A = Fr-1
Lsf = length of the spillway
µ = discharge coefficient of the spillway = 0,4
( ) ( ) ( ) ( )
−+⋅−⋅+−
+−⋅+⋅= 1
4
3111
8
112
0 iiifffsf yyAyyyAyQQ
Flow spilled over the crest of the lateral spillway during transient
![Page 78: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/78.jpg)
78
Transient phenomena
Surge tanks in low head plants
Plant Gardone
Maximum flow rate 4,5 m3/s
Minimum flow rate 1,2 m3/s
Average flow rate 3,0 m3/sGross head 27,30 mMaximum capacity (installed) 980 kW Annual hours of operation 8.000Annual production 4.000.000 kWhStart production 30/05/2002
![Page 79: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/79.jpg)
79
Transient phenomena
Surge tanks in low head plants
Section A: open channel (202,8 m)
Section A: siphoned channel (321,1 m)
Section A: cast iron penstock (254,5 m)
Section B,C,D1: GRP penstock (768,4 m)Section D2,E: steel & concrete penstock (357,1 m)Section E: tail race (358 m)
Surge tank
![Page 80: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/80.jpg)
80
Transient phenomena
Schematic profile of the plant
![Page 81: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/81.jpg)
81
Transient phenomena
Lesson learning: a brief history of THE PROBLEMS
Vacuum bubbles risk
Negative pressure stresses too
Positive pressure stresses
Action turbine
Action turbine
Notes
Sophisticated calculation model and field tests
Preliminary mathematical model implementation
First waterhammer evaluation
None
None
Consequences
DramaticSiphoned intakeConstruction project
Significant Kaplan turbine 750 rpm
Construction project
Not significantKaplan turbine 600 rpm
Second bid
NoneCross-flow turbine confirmed
First bid
NoneCross-flow turbine
Concept project
WATERHAMMER PROBLEMS
ITEMSPHASES
![Page 82: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/82.jpg)
82
Transient phenomena
Lesson learning: a brief history of THE SOLUTIONS
• Checking theoretical calculation
• Setting-up the hydraulic operating systems (wicket gates, blades and dissipation valve)
• Removing every plant limitation
Final field survey
• Dramatically cutting off the negative pressure waves
• Lowering the positive pressure waves
• Getting the plant full capacity
Surge tank erection
• Most dangerous operation situations taking into account the penstocks and the Kaplan unit together
• Best closing law of wicket gates and runner
• Geometric parameters of the surge tank
• Diaphragm optimum size to fulfil the boundary constrains
Sophisticate mathematical model
• Actual penstocks and Kaplan unit critical parameters (wave reflection time, flow rate gradient during the transients)
• Waterhammer effect on the penstock without the surge tank
• Set-up of the hydraulic system (wicket gates, runner blades, dissipation valve) to operate the plant in safe condition
First field survey
• Worst operating situations
• Maximum stresses in the penstock
• Plant operation limits to keep the stresses of the penstocks within safety range
Preliminary simulations
(without surge tank)
ISSUESITEMS
![Page 83: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/83.jpg)
83
Transient phenomena
![Page 84: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/84.jpg)
84
Transient phenomena
![Page 85: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/85.jpg)
85
Transient phenomena
Surge tank: assembly phase
![Page 86: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/86.jpg)
86
Transient phenomena
Surge tank
Tower net height 23,60 m
Diameter: 4,00 m
Material: steel S275JR
Thickness : 11 mm
![Page 87: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/87.jpg)
87
Transient phenomena
Waterhammer doesn’t mean only overpressure but negative pressure too, caused by the very quick increase of the flow rate during the shutoff transients, which could be more dangerous than positive pressure waves for the pipes
Transient phenomena must be duly investigated even for small low head plants where penstock have replaced conventional open-channel headrace channels
![Page 88: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/88.jpg)
88
Transient phenomena
![Page 89: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/89.jpg)
89
Transient phenomena
![Page 90: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/90.jpg)
90
Transient phenomena
Tr =0,45 s = 2*L/c < <Tc = 23 s
![Page 91: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/91.jpg)
91
Transient phenomena
![Page 92: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/92.jpg)
92
1. High head – low head: short overview of the different main problems
2. Lesson learnt in:
• New construction – high head / low head
• Rehabilitation - high head / low head
3. Difficulty in collecting information about failure
4. Failure analysis: what can go wrong in a plant.
5. Technical lesson learnt
6. Operational lesson learnt
![Page 93: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/93.jpg)
93
An automated and unattended plant doesn’t mean an abandoned plant!
![Page 94: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/94.jpg)
94
Don’t play with water!!! Maximum care in manual operation of hydraulic devices as valves, distributors….
0Vcp ⋅⋅=∆ ρ
Sayano-Sushenskaya accident2009-08-1775 people died
![Page 95: Luigi Papetti - unibs.ithydraulics.unibs.it/hydraulics/wp-content/uploads/2012/05/Papetti Hydro.pdf · Desilting gate too small. 45 What’s wrong Original sin - intake in the inner](https://reader033.fdocuments.in/reader033/viewer/2022042102/5e7f1f37e42771537d1288fc/html5/thumbnails/95.jpg)
95
g
VcHTT c
0⋅=∆⇒<
Penstock diameter 7 m