Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr....

3
Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – www.lubricus.de Lubricus Lubrication System – LUB-B & LUB-V Settings

Transcript of Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr....

Page 1: Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – .

Lubricus – settings and changes

LUB-B-1LUB-B-2

LUB-V-1LUB-V-2

Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – www.lubricus.de

Lubricus Lubrication System – LUB-B & LUB-V Settings

Page 2: Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – .

1a) To switch on Lubricus or make changes you need the ‘activation magnet’. The ‘nose’ of the magnet is your operating /programming key.

1) Commissioning of the system (switch on/switch off )

Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – www.lubricus.de

1c) To switch on/off Lubricus put the head of the magnet to the front of the unit (small deepening below display)

2d) Display shows „On“ (blinking) for 3 sec., if no further action is done Lubricus goes into the operating mode and operates according to the settings of P1 and P2.Device starts a test run (Display shows „run“) ; afterwards the required counter pressure (e.g. max07) is shown on the display.

2) Activate Lubricus/switch on

.OFF03 A 01 1P12 2P01 ON ON RUN .Max 07 ON

3a) Hold the magnet key to the “action area” until the red LED on the display flashes 3 times !=> Lubricus turns off, Display shows „OFF“

. 3) Switch off LubricusON ON OFF

1b) The magnet can be found at the top of the housing/plastic cover.Open the ventilation lock (turn clockwise to OPEN) and remove the activation magnet.

2a) Open ventilation lock (turn clockwise to OPEN) and remove the activation magnet.

2b) To switch Lubricus on hold the magnet key to the “action area” in front of the drive unit until the red LED on the display flashes 3 times => remove activation magnet

2c) Display changes from „OFF“ to „On“basic settings are shown at the display:a) Display : 03 = 3.0 V battery operation (Type LUB-V shows 24V) b) Display :A01 = 1 outlets or A02 = 2 outlets (depending on model) c) Display :P₁ 12 operating time/cartridge (basic setting 12 months)d) Display :P₂ 01 delivery rate (= number of strokes, each 0, 15 cm³, basic setting 1)

Lubricus Lubrication System – LUB-B & LUB-V Settings

Page 3: Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – .

Lubricus Lubrication System – LUB-B & LUB-V Settings

Grützner GmbH – Kohlenhofstr. 60 – 90443 Nürnberg Lubricus Schmiersystem – www.lubricus.de

4a) Follow the procedure described in 2), in other words: Þ Switch on Lubricus with the activasion magnet (red LED flashes red 3 times ) Þ Wait until basic settings are shown on the display Þ While the display is flashing „On“ ,touch the programming magnet until the red LED flashes two times (at the display) , then remove the operating magnet quickly

4) Lubricus – make changes to settings

.OFF03 A 01 1P12 2P01 ON ON

=> Touch the programming magnet to the action area until the red LED flashes twice=> remove magnet quickly and the Lubricus operates as described in 4d)

. Lubricus – Quick Check ON ON

1P12 1P13 1P14 1P15 1P16 1P17 1P18 1P19 1P20 1P21 1P22 1P23 1P24 1P251P261P271P281P291P301P011P021P031P041P051P062P01 2P02 2P03 2P04 2P05 2P06 2P07 2P08 2P09 2P10 2P11 2P12 2P13 2P14 2P15 2P16 2P17 2P18 2P19 2P20 2P21 2P22 2P23 2P24 2P25 2P26 2P27 2P28 2P29 2P30 2P01 2P02 2P03 2P04 2P05 2P06 1P311P321P331P341P351P36RUN .Max 07 ON .

run .Max 01 Max 03 Max 06 Max 08 Max 10 Max 11 ON

4b) Setting P1 Þ Hold the magnet while "ON" flashes about 2 seconds , then Display shows P1 12 (basic setting) => Touching the pad with the button will change the display (1 to 36 is possible)Holding the button on the pad causes the display to “run”, short touches will cause the display to increase by 1. Enter the desired setting. When the pad is not touched for more than 2 sec. the display moves on with the next step P₂.

4c) Setting P2

=>Touching the pad with the button changes the display (1 to 30 is possible)Holding the button on the pad causes the display to “run”, short touches will cause the display to increase by 1. Enter the desired setting.When the pad is not touched for more than 2 sec., setting is finished and data will be saved.

4d) Lubricus is ready for operationÞAfter removal of the magnet Lubricus goes over into the operating mode and works according to the settings P1 and P2.

=> Device starts a test run (Display shows „run“) and afterwards the required counter pressure (e.g. max07) is shown on the display.