www.ltr-lifts.co.uk
BLTR-ES EscalatorBLTR-CS Passenger Conveyor
-
7/30/2019 Lt r Brochure
2/23
BLTR-ESESCALATOR
The BLTR-ES series of escalators is designed and
manufactured according to the European Standard
EN115 Safety Rules for the Construction and Installation
of Escalators and Passenger Conveyors. Widely used in
large malls, supermarkets, underground systems,
railway stations, business centres and other public
places, this is an ideal transportation system for
connecting different floors.
The P Series is designed for extensive use in public
places and is suitable for both stylish commercialbuildings and more functional public buildings.
The M Series is designed for stylish buildings
such as department stores, hotels and office buildings.
This slim escalator features a narrow handrail that
is easily held, improving the comfort of passengers.
Its compact style sits easily in its surroundings, with a
modern look and feel.
The G Series is designed for underground systems,
stations and arcades. It has the ability to run
continuously for long periods while dealing with heavy
passengers flow. The stainless steel balustrade option is
ideal for demanding environments.
We offer many optional functions to meet various
requirements.
Our escalators comprehensive specifications, flexible
layouts and stylish and ergonomic design combine in
products that are convenient to run and maintain.
Top quality materials, advance manufacturing methods
and equipment ensure that these products are safe,
solid, durable and stable.
-
7/30/2019 Lt r Brochure
3/23
InformationDisplayer
Displaying the running
condition or failure makes
maintenance faster
and more convenient,
as well as providing
basic information for
passengers.
AutomaticLubrication
The system lubricates
the motion components
to reduce maintenance
work.
Roller pressingbelt device
This ensures the smooth
running of the handrail
and gives customers
an increased sense of
security. It also reduces
the frequency of
maintenance work to a
minimum.
ESCALATOR BLTR-ES
Stainless Steel Step
The anti-slip design of the stainless steel step improves passenger safety.
The escalator benefits from the most advanced control technology and control
concept. This has the advantages of safety and reliability, stability, comfort and
energy and economic efficiency. Its flexibility means that it can meet the different
needs of different customers.
Many control systems adopts PLC, which has the advantages of strong anti-
interference ability, stability and reliable running.
The VVVF+PLC control, in which the starting current is reduced through an inverter,
significantly reduces energy consumption. It also ensures that the escalatorsoperation is stable and prolongs its service life.
Adopting inverter control means that when a passenger is detected, the escalator
will start slowly and then travel at normal speed.
It will stop or slow down if there are no passengers, reducing running time and
saving energy.
-
7/30/2019 Lt r Brochure
4/23
AUTOMATIC STARTING
The escalator is able to run automatically when it detects a passenger, which makes it particularly energy-efficient.
When the passenger enters the detection area, the escalator starts running or returns to a normal operating speed from
a lower speed. If there are no passengers at set intervals, the escalator returns to its original setting.
This function makes the escalator suitable both for hotel and office buildings with a light customer flow, and for
underground or station systems with heavy customer flow.
ESCALATOR BLTR-ES
There are a range of design options available to customers. These allow the escalator to co-ordinate with and
complement the surrounding environment.
ENTRANCE FLOOR
Stainless Steel (standard)
Belt Shape Aluminum (optional)
COLORS OF HANDRAIL
01 standard 02 optional 03 optional 04 optional
05 optional 06 optional 07 optional 08 optional
Working Condition
of Indicator
No-Entry Conditionof Indicator
-
7/30/2019 Lt r Brochure
5/23
ESCALATOR BLTR-ES
TECHNICAL EQUIPMENTIntegrated Track Welding Equipment for Trusses (above)
We have developed and designed our own integrated track welding
equipment for trusses for escalators and passenger conveyors. The
main benefits of this professional quality equipment are:
High manufacturing accuracy, quick and accurate positioning,
0-35 random adjustment of angle.
The escalator truss can be erected, welded and lifted to 2-8m inone operation.
The trimming system adopts imported bearings, straight-line
guide rails and micro-loading adjustment devices to ensure
higher manufacturing accuracy of the truss.
The sophisticated manufacturing processes used ensure equipment of the highest quality.
-
7/30/2019 Lt r Brochure
6/23
ESCALATOR BLTR-ES
FO-3015 digital control laser processing machine Digitally controlled bending machine
STEP RUNNING TRACK AND TRANSMISSION PARTS
The key parts for the running track are processed by Japanese laser cutting machines to ensure precision and quality.
The guide rails of the upper and lower step running track is made of high-quality steel. Produced using a digital control
bending machine, they combine high precision dimensions and durability.
The components of the upper and lower step running track parts and the driving device are made by precision
processing equipment and special technical equipments. These have reached a new level in stable running, with
reduced noise.
The step is oriented completely on the step running track, to ensure smoother running quality.
-
7/30/2019 Lt r Brochure
7/23
ESCALATOR BLTR-ES
1
2 3
4
5
6 7
8
9
10
11
12
13
Standard Safety Function
1 Emergency stop switchIn case of emergency, pushing this button
will stop the escalator.
2 Overload protectionWhen overloaded, the power will be cut,and the escalator will stop.
3 Phase loss and failure protectionThe escalator will stop running when power is lost orphase failure occurs.
4 Electromagnetic brake
This guarantees the appropriate braking distance forpassenger safety when the escalator stops.
5 Comb safety deviceTo ensure passenger safety and prevent damage, if anobject is stuck between the step and the comb plate,the escalator will stop.
6 Unintentional reversal of the direction of travel
The direction of travel cannot be changed while theescalator is moving.
7 Over speed governor
The escalator will stop if the unit overspeeds.8 Drive chain guard
The escalator will stop if the drive chain isexcessively pulled or broken.
9 Step safety deviceIn abnormal conditions, caused by deformation ordamage to the step, the escalator will stop.
10 Yellow demarcation line
The demarcation on the step indicates the safe areafor passengers to stand.
11 Skirt Panel Safety Switch
If an object is stuck between the step and skirt panel,the escalator will stop, ensuring passenger safety andpreventing damage.
12 Handrail entry safety deviceIf an object is stuck to the handrail, the escalator willstop, ensuring passenger safety and preventing damage.
13 Step entry safety device
The escalator will stop if the traction chain isexcessively pulled through or broken.
Optional Safety Function
Handrail speed monitoringThe escalator will stop if the handrail isbroken or running at low speed.
Auxillary brakeIf the drive chain is broken and/or the
escalator travels at 120% of normal speed,the brake stops the escalator.
Step number monitoringIf a step is missing, the escalator will stopbefore it enters the comb plate.
-
7/30/2019 Lt r Brochure
8/23
-
7/30/2019 Lt r Brochure
9/23
-
7/30/2019 Lt r Brochure
10/23
ESCALATOR BLTR-ES
P30 Series Escalator Construction Layout DrawingRise Height 1.2mH6m Number of Horizontal Steps: 2
Note: 1.The unit of measurement in the illustration is the millimetre. For enlarged drawing A, see page 14.
2. For outdoor escalators, the dimension marked # in the drawing is 1340mm.
Dimension
BLTR-P30/60
BLTR-P30/80
BLTR-P30/100
W1 (Step Width) 600 800 1000
W2 (Handrail Width) 910 1110 1310
W3 (Pit Width) 1340 1540 1740W4 (Escalator Width) 1200 1400 1600
W5 (Well Width) 1260 1460 1660
W6 (Well Width) 1910 2110 2310
Type Rise Height 3000 3500 4000 4500 5000 5500 6000
BLTR-P30/100
Net Weight G(KN) 66 70 74 78 86 90 94
Reaction ofSupport
R1(KN) 62 66 70 74 80 85 89
R2(KN) 54 58 62 66 72 77 81
Power P(KW) 5.5 8 11
BLTR-P30/80
Net Weight G(KN) 62 66 70 73 77 81 85
Reaction ofSupport
R1(KN) 55 58 62 66 69 73 77
R2(KN) 47 51 54 58 61 65 69
Power P(KW) 5.5 8 11
BLTR-P30/60
Net Weight G(KN) 59 62 66 69 73 77 80Reaction of
Support
R1(KN) 48 51 54 57 61 64 67
R2(KN) 40 43 47 50 53 56 59
Power P(KW) 5.5 8
-
7/30/2019 Lt r Brochure
11/23
ESCALATOR BLTR-ES
M35 Series Escalator Construction Layout DrawingRise Height 1.5mH6m Number of Horizontal Steps: 2
Note: 1.The unit of measurement in the illustration is the millimetre. For enlarged drawing A, see page 14.
2. For outdoor escalators, the dimension marked # in the drawing is 1340mm.
Dimension
BLTR-M35/60
BLTR-M35/80
BLTR-M35/100
W1 (Step Width) 600 800 1000
W2 (Handrail Width) 838 1038 1238
W3 (Pit Width) 1340 1540 1740W4 (Escalator Width) 1200 1400 1600
W5 (Well Width) 1260 1460 1660
W6 (Well Width) 1840 2040 2240
Type Rise Height 3000 3500 4000 4500 5000 5500 6000
BLTR-M35/100
Net Weight G(KN) 62 66 69 73 77 80 85
Reaction ofSupport
R1(KN) 58 62 65 69 72 76 81
R2(KN) 50 53 57 61 64 68 73
Power P(KW) 5.5 8 11
BLTR-M35/80
Net Weight G(KN) 59 62 65 69 72 75 79
Reaction ofSupport
R1(KN) 52 55 58 61 64 67 70
R2(KN) 43 47 50 53 56 59 62
Power P(KW) 5.5 8
BLTR-PM35/60
Net Weight G(KN) 56 59 62 65 68 71 75Reaction of
Support
R1(KN) 45 48 51 53 56 59 61
R2(KN) 38 40 43 46 48 51 53
Power P(KW) 5.5 8
-
7/30/2019 Lt r Brochure
12/23
-
7/30/2019 Lt r Brochure
13/23
ESCALATOR BLTR-ES
G35 Series Escalator Construction Layout DrawingRise Height 2.5mH6m Number of Horizontal Steps: 3
Note: 1. For enlarged drawing A, see page 14.
2. For outdoor escalators, the dimension marked # in the drawing is 1340mm.3. In the formula for the reaction of the bearing carrier, the unit of measurement for dimension L is metres.
The unit of measurement for other dimensions is the millimetre.
Dimension
BLTR-G35/80
BLTR-G35/100
W1 (Step Width) 800 1000
W2 (Handrail Width) 1110 1310
W3 (Pit Width) 1540 1740W4 (Escalator Width) 1400 1600
W5 (Well Width) 1460 1660
W6 (Well Width) 2110 2310
Reaction of Bearing Carrier (Unit: KN)Reaction R1 R2
Step Width800 4.63L+14.47 4.78L+4.71
1000 5.04L+15.20 5.21L+5.00
-
7/30/2019 Lt r Brochure
14/23
ESCALATOR BLTR-ES
G30 Series Escalator Construction Layout DrawingRise Height 2.5mH6m Number of Horizontal Steps: 3
Note: 1. For enlarged drawing A, see page 14.
2. For outdoor escalators, the dimension marked # in the drawing is 1340mm.
3. If the step width is 1000 and the rise height is 9000H10000, add 500 to the
dimension marked # in the drawing.
4. In the formula for the reaction of the bearing carrier, the unit of measurement for dimension L is metres.
The unit of measurement for other dimensions is the millimetre.
Dimension
BLTR-G30/80
BLTR-G30/100
W1 (Step Width) 800 1000
W2 (Handrail Width) 1110 1310
W3 (Pit Width) 1540 1740W4 (Escalator Width) 1400 1600
W5 (Well Width) 1460 1660
W6 (Well Width) 2110 2310
Reaction of Bearing Carrier (Unit: KN)
Rise Height 2500
H
6000 6000
H
10000Reaction R1 R2 R1 R2 R3
StepWidth
800 4.54L+14.52 4.55L+5.07 2.14L+13.57 2.24L+3.35 5.64L+4.08
1000 4.94L+15.27 5.22L+5.24 2.26L+17.65 2.67L+3.36 6.20L+5.44
-
7/30/2019 Lt r Brochure
15/23
-
7/30/2019 Lt r Brochure
16/23
TECHNICAL If the escalator is installed above the bottom floor, the pit is not required. The construction of both the downside and
upside of the escalator should be symmetrical.
At both top and bottom escalator landings, there must be sufficient unrestricted space to accommodate passengers.
The width of this area should at least correspond to the distance between the handrail centrelines. The depth must be
at least 2.5 metres, measured from the end of the balustrade. However, this can be reduced to two metres if the width
of the unrestricted area is increased to at least double the distance between the handrail centrelines.
The distance between the centreline of the handrail and any obstacle must be equal to or greater than 0.5m.
Power Supply: four wire three phase 415VAC 7%, 50HZ Lighting. Source: single phase 220VAC, 50HZ
The user must provide an earthing unit with less than 4 Ohm resistance.
User must provide lighting of at least 50Lx (testing value from the ground) at the entrance to an indoor or outdoor
escalator.
ESCALATOR BLTR-ES
ENLARGED DRAWING A
-
7/30/2019 Lt r Brochure
17/23
USER RESPONSIBILITIES
Calculations with regard to the building
Builders work, such as forming the well, pit and/or machine room, to interface with the escalator dimensions as
detailed on LTR general arrangement drawings
Cutting away and making good
Site painting after installation, other than bright parts or factory finished surfaces
Treatment of escalator area to inhibit the formation of dust
Suitable lifting and pulling points to suit LTRs requirements
Levels for sizing of escalators Any reinforcement necessary for load bearings, together with properly located supports of adequate strength for
truss at upper and lower landings, and intermediate supports
Any necessary drainage, tanking, lining or reinforcing of escalator area Guarding of openings and other measures necessary to ensure the safety and convenience of the occupants and
other personnel within the building
Scaffolding, load-bearing platforms, planks, ladders and temporary screening, to LTR requirements Storage of materials, tools and clothing in a suitably locked, dry, heated and illuminated storage space, protected
from theft and damage
Suitable temporary and permanent power supplies for tools and equipment, shutters and the operation of theescalators, in accordance with an agreed programme
Mess rooms, sanitary accommodation and welfare facilities
A roadway or equal immediately adjacent to the building entrance, where off-loading will take place. Thereinforcement of paving and floors, making suitable access
Provision of ramping, protection and all necessary access space for unloading, hoisting or lowering of the escalator,
in or outside the building or within the escalator well, and for the handling to its final position Suitable floor openings, properly framed and finished in accordance with LTRs drawings, all permanent
enclosures, shutters, railings, sprinklers and smoke baffles for the escalator area that may be required Proper covering of the escalator for protection against damage and contamination until acceptance. Cleaning down,
renewal or replacement of equipment damaged by dust produced from other contractors processes, such as drygrinding of mosaic and other builders work
As may be necessary for escalators installed in the open, working scaffolding of proper height and temporaryscreening around the passenger conveyor, consisting of working weatherproof cover, with heating if necessary,for the protection of the workmen concerned. The provision of drains connected to the lower outlet end of drip trayscapable of dealing with the most abnormal rainfall
Extra costs due to surveyors fees or special requirements of government departments, local authorities, insurance
companies, consultants, other bodies or officials Provision of safe and adequate access to the site and escalator area, to the satisfaction of the Health and Safety at
Work Act
Provision for taking on any of the roles specified in the CDM Regulations other than that of contractor
ESCALATOR BLTR-ES
-
7/30/2019 Lt r Brochure
18/23
BLTR-CS PASSENGER CONVEYOR The BLTR-CS passenger conveyor is designed and
manufactured according to the European Standard
EN115 Safety Rules for the Construction and Installation
of Escalators and Passenger Conveyors. It is widely
used in supermarkets, underground systems, airports
and other public places.
Advanced manufacturing and technical equipment
guarantee a high quality product.
The truss is made of high quality rectangle steel pipe.
The design and compact structure of the stainless steel
pallets make full use of the building space. The pallets
are designed with anti-slip grooves for passenger safety
and comfort.
Faults can be indicated in the display window, making
maintenance more convenient.
Various handrail colours are available to blend stylishly
with the conveyors surroundings.
-
7/30/2019 Lt r Brochure
19/23
Safety Standard Function
1 Electromagnetic brakeGuarantees the appropriate braking distance when the
passenger conveyor stops.
2 Main power switchThe main power switch for the passenger conveyor.
3 Overload protectionWhen the drive motor is overloaded, the power supplyis automatically cut off and the passenger conveyorstops.
4 Power phase failure and wrong phase protection
When a power failure phase or phase failure occurs, thepassenger conveyor stops.
5 Unintentional reversal of the direction of travelThe direction of travel cannot be changed while thepassenger conveyor is moving.
6 Overspeed governorThe passenger conveyor will stop if the unitoverspeeds.
7
Drive chain guardThe passenger conveyor will stop if the drive chain isexcessively pulled or broken.
8 Comb safety deviceTo ensure passenger safety and prevent damage, if anobject is stuck between the step and the comb plate,the passenger conveyor will stop.
9 Handrail entry/safety deviceIf an object is stuck to the handrail, the passenger
conveyor will stop, ensuring passenger safety andpreventing damage.
10 Emergency stop switchIn case of emergency, pushing this button will stop thepassenger conveyor.
11 Skirt panel safety switchIf an object is stuck between the step and skirt panel,the passenger conveyor will stop, ensuring passengersafety and preventing damage.
12 Pallets safety deviceIn abnormal conditions caused by deformation or otherreasons, the passenger conveyor will stop.
13 Pallet chain guardIf the pallet chain is excessively pulled through orbroken down, the passenger conveyor will stop.
Optional safety function
Handrail speed monitoringIf the handrail breaks, or its working speed is low, thepassenger conveyor will stop.
Auxillary brakeIf the drive chain breaks, or the passenger conveyorexceeds the rated speed by 12%, the auxiliary brakestops the passenger conveyor. This is standard forpassenger conveyors with a rise height more than sixmetres.
Pallet monitoringIf a pallet drops, this ensures that the passengerconveyor stops before the pallet enters the comb plate.
PASSENGER CONVEYOR BLTR-CS
1 2
3
456
7
8911 10
1011
12
12
8
9
13
-
7/30/2019 Lt r Brochure
20/23
PASSENGER CONVEYOR BLTR-CS
1 Handrail 2 Handrail Bracket 3 Handrail Balustrade 4 Skirting 5 Pallet
6 Interior/exterior Decking 7 Comb Light 8 Comb 9 Entrance Floor
1
2
3
4
5
6
7
8
9
Pallet Width (mm) 1000 800
Theoretical Capacity (Person/h) 9000 6750
Rated Speed (m/s) 0.5
Angle of Inclination 0~6 11/12
Power Supply 50 Hz AC Three Phase 380V Single Phase 220V
Motor Three Phase AC motor
Operation TypeStandard Star-delta starting
Option Payable VVVF
Control Type PLC
Product All Series
HandrailStandard
Handrail Bracket Anode oxidic aluminum alloy Hairline Stainless steel
Handrail Balustrade Intensive safety glass with 10mm thick
Handrail Black composite rubber
Handrail Light Yes No
Interior/Exterior Decking Hairline Stainless steel
Skirting Hairline Stainless steel
Option Payable Handrail Many kinds of colour
EntranceFloor
Standard
Comb Aluminum alloy
Entrance Floor Stainless steel
Comb Light Groove aluminum profile
Option Payable Comb Light Yes
Pallet Stainless steel
SPECIFICATION DATA AND STANDARD ACCESSORIES
-
7/30/2019 Lt r Brochure
21/23
BLTR-CS 11 - 12 Series Passenger Conveyor Construction Layout Drawing
Note: 1. If L>E, one intermediate support shall be installed; If L>F, two intermediate supports shall be installed.
2. For outdoor conveyors, the dimension marked # in the drawing will be 1400mm.
3. All dimensions in millimetres except where marked.4. Please contact us if the angle of inclination does not conform to our standard.5. We have the right to modify data. Please confirm further before signing any contract.
If there is one support, use L/2 dimension, otherwise use L/3 dimension.
PASSENGER CONVEYOR BLTR-CS
TypeAngle of
Inclination ()Tread
Width AL1 L2 L3 L4 L
BLTR-Z11/100 111000
1900 1090 4420 195 5.1446xH+2990
BLTR-Z11/80 800
BLTR-Z12/100 12
10001955 1080 4120 204 4.7046xH+3035
BLTR-Z12/80 800
Tread Width A B C D E F
1000 1238 1600 1700 15000 30000
800 1038 1400 1500 16300 32600
-
7/30/2019 Lt r Brochure
22/23
TypeAngle of
Inclination ()Tread
Width AB C D
BLTR-Z6/1000-6
1000 1238 1600 1700
BLTR-Z6/80 800 1038 1400 1500
BLTR-CS 0-6 Series Passenger Conveyor Construction Layout Drawing
Note: 1. For outdoor conveyors, the dimension marked # in the drawing will be 1400mm.
2. All dimensions in millimetres except where marked.
3. Please contact us if the angle of inclination does not conform to our standard.4. We have the right to modify data. Please confirm further before signing any contract.
PASSENGER CONVEYOR BLTR-CS
-
7/30/2019 Lt r Brochure
23/23
LTR Lifts & Escalators Ltd Graphic House Druid StreetHinckley Leicestershire LE10 1QH
Tel: 01455 633760 Fax: 01455 636005e-mail: [email protected]
www.ltr-lifts.co.ukwww.ltr-lifts.co.uk