LS SmartConnect
LS Control A/S
Control platforms
Ventilation Heat
pumpHeatexchange
Software
HeatSupply
Hotwater
AppInternetservice
Lowprice
Easyinstall
Comfort Combination
LS SmartConnect is our solution for connecting your product on the internet to give you the possibility of monitoring, servicing and controlling using an appand PC tools.
LS SmartConnect includes ard are for new and h wexisting product solutions. It also includes oftare s wfor programming the controller, for monitoring, servicing and adjusting the finished product solution event over the internet and by use of an p.ap
Content of Document2 Description of Solution Components
3 LS SmartConnect Log
4 LS SmartConnect App
5 LS SmartConnect Center
6 LS SmartConnect Config
7 LS SmartConnect GateWay
8 LS SmartConnect ES 2020 Platform
9 Describing the ES 2020 PCB
10 The ES 2020 Cabinet
11 Overview of Input / Output Options
12 Configuration Example 1: Typical Use of ModBus
13 Configuration Example 2: Heat Exchanger with Water Based Heating and Cooling
14 Configuration Example 3: Rotary Heat Exchanger with Water Based Heating and Cooling
15 Configuration Example 4: Heat Exchanger with Electrical Heating and Cooling
16 Accessories
LS SmartConnect Description of Solution Components
LS SmartConnect - Server The server / cloud handles all connected units. Only units with LS Control developed hardware can be connected. Access to connected products is granted through obtained license rights. From the Manufacturers access to several connected units all the way down to each individual user with access to only his own unit (Typically via an pp).a
For any level of customer/user to get access to connected products/units he must be a member of LS SmartConnect. Regardless if product is with integrated internet access such as ES 2020 or the access is obtained via our GateWay and regardles if access is sobtained via pp or PC tools.a
SoftwareLS SmartConnect - Log
The Log software is a technicians tool for accessing a ventilation system, heatpump etc which is connected to the .internet with access to our server. However, the software is also to be used locally typically using the port of a PC.USBTo analye a ventilation system, heat pump etc using the Log z .software demands a log vesion corresponding to the product rneeding to be analyed. This implies you need several log zversions to analye different products. zYou may use Log to set ModBus values and in an advanced Log system you are able to monitor the actual operation.
LS SmartConnect - app App is an application for Smartphones and tablets for the end-user to operate his heat pump / ventilation system.
App is only to be developed for products connecting to the internet and with an integrated Nabto License (such as the 2020-platform) or with internet access through the LS SmartConnect GateWay (offering ModBus to LAN and using Nabto license).
App is developed for both Android and Apple.
LS SmartConnect - Center This monitoring software is a software including more levels and where the Ventilation system, heat pump manufacturer buys a SuperUser licence giving the opportunity to resell sub-licenses for service companies or retailers. The Center monitors all the manufactures customers connected units. ‚
Errors / Status simultaneously displayed for all connected areunits, but only for the level you are licensed for. Giving each level access to exactly the units needed to service and monitor his customers.
LS SmartConnect - ConfigConfiguration tool for LS Control product hardware platform called ES 2020 (Described in this document). The configuration tool gives the possibility of customie znumerous output and input options. This tool has nothing to do with the internet. The objective of this tool is solely for customers to quickly be able to configure hardware to readily be obtained in solution applications without the use of LS Control development department.
LS SmartConnect - GateWay
LS SmartConnect - ES 2020Hardware platform to be configured for
Air handling unitsAir handling units with passive heat pump.
And many more
This hardware box provides the access from a ModBus protocol to a LAN connection to the internet.
To obtain the connection through the GateWay it is necessary to get a little piece of translation software developed to translate the existing ModBus addresses to LAN Connection addresses which can be understood by the LS SmartConnect Server giving access to Log, Center or pp.aTo use the LS SmartConnect GateWay it is mandatory to obtain license for our server.
Nabto connection and internet security.Nabto is a middleware integrated with our SmartConnect hardware products. Nabto provides a secure connection between the users phone/tablet and the SmartConnect ‚
product, using industry standard cryptography. Each product is given a unique device-id which is used by the client to reach it, regardless of dynamic IP addresses. The Nabto middleware provides seamless, direct remote access without firewall or router configuration. The direct Nabto connection ensures the best possible performance with minimal overhead and latency
Hardware
LS SmartConnect LOG
Provides a graphical overview of the heat pump / ventilation system performance and the possibilities of setting and adjusting the ModBus values to improve the overall performance.
Vent hastighed
1
The first time the appis startedOr if the user not is logged in.
In case of malfunction at the unit. Alarms
Start screen withcompany logo. Scwitches after 2 seconds
Connectedmodel / type
If user is created and logged in
If there is a user.at the unit
If no available user at the unit
LS SmartConnect App
125320210675
175937221851
308258681780
511639346080
592306484662
755686817020
Add device
Welcome select device
By: LS CONTROL A/S
Status: OK
Temperature: 35°C
Fan speed: 3
Reheet: Off
Settings
Model: XXXXXX
By: LS CONTROL A/S
125320210675
175937221851
308258681780
5116346080
592306484662
755686817020
Add device
Welcome select device
By: LS CONTROL A/S
Create user
Selected device 755686817020
Enter E-Mail
Cancel OK
E - mail
Active user: [email protected]
Back
135320210675
755686817020
Add ID
Delete user
Forgot password
Logout
Devices
Delete Active
Active
User exists
1
Login
Forgot password
Delete user
Selected device: 755686817020
BackUser exists
Options Connection Information
By: LS CONTROL A/S
Ny bruger
Back
Options Connection Information
Fan speed: 3
Temperature: 20,50°C
Reheat
By: LS CONTROL A/S
On/Off
Status: OK
Temperature: 35°C
Fan speed: 3
Reheet: Off
Settings
Model: XXXXXX
By: LS CONTROL A/S
Status: OK
Temperature: 35°C
Fan speed: 3
Reheet: Off
Settings
Model: XXXXXX
By: LS CONTROL A/S
Status: Alarm
Temperature: 700°C
Fan speed: 3
Reheet: Off
Settings
Model: XXXXXX
By: LS CONTROL A/S
Back
By: LS CONTROL A/S
Main filter
Frost
External Filter
Alarms
By: LS CONTROL A/S
off
Back
Options Connection Information
By: LS CONTROL A/S
Modbus information 1
Modbus information 2
Modbus information 3
Modbus information 4
Modbus information 5
Modbus information 6
Modbus information 7
Modbus information 8
Modbus information 9
Modbus information 10
Modbus information 11
Name the unit with your known name:
Active user: [email protected]
Back
Unit name:135320210675
755686817020
Add ID
Delete user
Forgot password
Logout
Delete Active
Active
Options Connection Information
By: LS CONTROL A/S
Name
Name
Active user: [email protected]
Back
135320210675
755686817020
Add ID
Delete user
Forgot password
Logout
Devices
Delete Active
Active
Options Connection Information
By: LS CONTROL A/S
Name
Create user
Selected device 755686817020
Enter E-Mail
Cancel OK
E - mail
Name devicer
Selected device 755686817020
Enter Name
Cancel OK
Name:
Site 1
All OK
Site 2
Alarm at unit 9
Site 7
All OK
LS SmartConnect Center
Alarm
Alarm
Site AlarmFavorite
PC tool for monitoring several units at the same time.
LS SmartConnect Center
Site 2
___
Site
Dev ID:
Dev ID:
Dev ID:
Dev ID:
Dev ID:
Dev ID:
LS SmartConnect Center
Device: 1122334455 Name: Uint 9 Man: WW2 Cust: Donald Duck, Denmark CPHAlarmlogDevice Status
Site 2
Config
LS SmartConnect Center
PC tool for configuring the ES 2020 hardware platform.LS SmartConnect Config
App
Datalogger
Datalog MODBUS®
Existing control system
MODBUS® Protocol— —— —— —— —
LAN
MODBUS®
Power Supply
Datalog stores 120 data entrieswhich is logged every one and a half minute in 150 days. The datacan be shown and analyzed in thedatalogger SoftWare.
Gateway
LS SmartConnect GateWayAn universal box providing a gateway from existing equipment using ModBus protocols to the internet via LAN.
LS SmartConnect GateWay requires customer specific software developed on the basis of data lists, protocols, set points etc.
The LS SmartConnect GateWay provides the possibility of getting existing models of equipment on the internet, opening for the use of LS SmartConnect app and LS SmartConnect Center.
LS SmartConnect ES 2020 Platform
for
Air handling unitsAir handling units with passive heat pump.
And many more
ES 2020 is a versatile platform.All inputs and outputs can be configured and all functions customized and adjusted using the configuration tool LS SmartConnect Config. This makes the ES 2020 platform very versatile as you may program it for numerous different applications, customizing your product to meet exactly your specific requirements.
However, If you want us to, we still offer to do the programming to customize the ES 2020 to your specific requirements.
ES 2020 has integrated LAN access ensuring your possibilities for getting your equipment on the internet.
When your product is connected to the Internet, user levels can be accessed through LS SmartConnect software, which provides a very unique and future-proof tool to provide customers with the best possible experience and a highly reliable service system.
LS Control A/S
Control platforms
Ventilation Heat
pumpHeatexchange
Software
HeatSupply
Hotwater
AppInternetservice
Lowprice
Easyinstall
Comfort Combination
Power sideLow power side
What́s inside connections.
Internal flash memory 256Mbit
LANWith Nabto
H1
L12
Micro USBA B
C
Optional
Wireless
Modul for wireless sensors andhome auto-mationstuff..
Build in power - supply 1A / 24V -24VA0,5A for external use.
Build in fuses
Build in fusesL1
L2
L3
L4
L5
L6 L7
L8
L9 L10
L11
L13
L14
H2 H3
H4 H5
H6 H7
H8 H9
H10 H11
H12 H13
H14 H15
H16 H17
T1T110K
T210K
T310K
T410K
T510K
T6 T610K
T7 T710K
T8 T810K
L1 / 4 x analog output + 1 x 10K NTC sensor Aout1 / Aout2 / Aout3 / Aout4 0-10V / T1
L2 / 3 x 10K NTC sensor. ÷ 30 to +130°C T2 / T3 / T4 NTC input can be changed to Digital input in software
Ao2 Ao3 Ao4 Gnd
L3 / 3 x digital input / D1 D2 D31 x analog input / Ai11 x 10K NTC sensor T5
L4 / 3 x 10K NTC sensor. ÷ 30 to +130°C T6 / T7 / T8 NTC input can be changed to Digital input in software
Ai2 Ai3 Ai4 Ai5 Ai6 +5V
L5 / 5 x analog input / Ai2Ai3 / Ai4 / Ai5 / Ai6 Conetcor L7 - 7 = +5V DC output for humidity sensor
24V Di4 Di5 Di6
L6 Power 24V - 0.5A / 12VA // The load 0,5A .total for connected accessories
L7 / 3 x digital input Di4 Di5 Di6
NpN 2 NpN 3
L10 (1-6) 2 x EC motor L10 (7) 1 x NPN output
L11 MOD-BUS 1 L12 2 x NPN output / NPN2 - NPN3
L11 MOD-BUS 2
DIP SWITCH
L13 MOD-BUS 3
L14 MOD-BUS4
L12 Mini USB / connects PC
H1 - 230V PowerSupply Max 16A
H3 / 230V / L - N output (no fuse) after heat.
H2 / 230V / L - N output (no fuse) preheat.
H5 / 230V / L - N output for compressor heat pump.
H4 / Indput from high pressure switch in heat pump systems
H7 / 230V / L - N output Fan 2
H6 / 230V / L - N output Fan 1
H9 / 230V / L - N output
H8 / 230V / L - M - N - output 230V Bypass damper
H11 / 230V / L - N output
H10 / 230V / L - N output Open afterheat Open water cooling
H12 2xPotential-free 5A resistive 24V
H13 H-bridge 100mA nominel 24VDC
H14 E-valve1 12VDC 3W
H15 Pt1000 sensor T9
H16 E-valve2 12VDC 3W
H17 Pt1000 sensor T10
24V/12V or low power
A B GND +24
A B GND +24
A B GND +24
A B GND +24
T2 T3 T4
T5
TachoE1c
TachoE1c
NpN 1
Ground connection:Point for collection of 12 ground connections
Describing the ES 2020 PCB
The ES 2020 Cabinet
114 mm
210 mm
223 mm
Depth
55 mm17 mm
Connectors All pluggable pcb connectors are with screw terminal.
200 mm
LS SmartConnect ES 2020 Overview of Input / Output ConnectionsContinued...
Connector Terminal 1 TypeL1 1 Analog out 1 0-10V 10mAL1 2 Analog out 2 0-10V 10mAL1 3 Analog out 3 0-10V 10mAL1 4 Analog out 4 0-10V 10mAL1 5 Gnd 0VL1 6 T1 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L1 7 T1 L2 1 T2 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 2 T2L2 3 T3 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 4 T3L2 5 T4 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 6 T4L2 7 Gnd 0VL3 1 Di1 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 2 Di2 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 3 Di3 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 4 Gnd 0VL3 5 Analog in 1 0-10V índput / resistance 100K L3 6 T5 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L3 7 T5L4 1 T6 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 2 T6L4 3 T7 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 4 T7L4 5 T8 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 6 T8L4 7 Gnd 0VL5 1 Analog in 2 0-10V índput / resistance 100K L5 2 Analog in 3 0-10V índput / resistance 100K L5 3 Analog in 4 0-10V índput / resistance 100K L5 4 Gnd 0VL5 5 Analog in 5 0-10V índput / resistance 100K L5 6 Analog in 6 0-10V índput / resistance 100K L5 7 5V ref. supply Load 20mA maximumL6 1 24V supply Load extern power 500mA maximum ( 400mA if including H-Bridge)L6 2 Gnd GND/0Volt for internal powersupply max. 1000mA L7 1 Di4 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 2 Di5 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 3 Di6 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 4 Gnd 0VL8 1 EC motor 1 Tacho EC motor Tacho feedback (open collector)L8 2 EC motor 1 0-10V 0-10V 10mAL8 3 EC motor 1 gnd 0VL8 4 EC motor 2 Tacho EC motor Tacho feedback (open collector)L8 5 EC motor 2 0-10V 0-10V 10mAL8 6 EC motor 2 gnd 0VL8 7 Npn 1 24V to load / NPN 100mA to Gnd
Connector Terminal 1 TypeL9 1 ModBus 1 - A RTU 9600 / 19200 A=Data +L9 2 ModBus 1 - B RTU 9600 / 19200 A=Data ÷L9 3 ModBus 1 Gnd 0VL9 4 Modbus 1 / +24V Part of total 24V powersupply 500mAL10 1 Npn 2 24V to load / NPN 100mA to GndL10 2 Npn 3 24V to load / NPN 100mA to GndL11 1 ModBus 2 - A RTU 9600 / 19200 A=Data +L11 2 ModBus 2 - B RTU 9600 / 19200 A=Data ÷L11 3 ModBus 2 Gnd 0VL11 4 Modbus 2 / +24V Part of total 24V powersupply 500mAL12 1 MicroUSB USB OTG (On The Go) / USB can be host or deviceL12 1L13 1 ModBus 3 - A RTU 9600 / 19200 A=Data +L13 2 ModBus 3 - B RTU 9600 / 19200 A=Data ÷L13 3 ModBus 3 Gnd 0VL13 4 Modbus 3 / +24V Part of total 24V powersupply 500mAL14 1 ModBus 3 - A RTU 9600 / 19200 A=Data +L14 2 ModBus 3 - B RTU 9600 / 19200 A=Data ÷L14 3 ModBus 3 Gnd 0VL14 4 Modbus 3 / +24V Part of total 24V powersupply 500mADIP Select Select differint programmed softwareLed A LED info Indication processor runningLed B LED info Indication ERROR // Connect LOG og Center for informationLed C LED info Indication Lan OK = Internet connectedLed D LED info Indication Modbus = Modbus running and OK
H1 230V 230V Powersupply (Max. 16A)H2 230V 230V out for preheat / No fuseH3 230V 230V out for afterheat / No fuseH4 Switch in Indput from high pressure switch / Heatpump systems 230V uninsulatedH5 230V 230V out for compressor / No fuseH6 230V 230V Fan 1 (FUSE 5A)H7 230V 230V Fan 2 (FUSE 5A)H8 230V + M L / M / N for 230V on off damper (FUSE 5A)H9 230V 230V out for ? (FUSE 5A)H10 230V 230V out open afterheat (FUSE 5A)H11 230V 230V out open wather cooling (FUSE 5A)
Low Power H12 1 and 2 Switch Switch 5A resitive 24V for ?H12 3 and 4 Switch Switch 5A resitive 24V for ?
H1324Vout for H-bridge damper motor 100mA / Stop will be entered in programs / as power a limit
H14 1 and 2 E-Valve 1 ETS6 Danfoss 1 = red 2 = black (coil2 96ohm)H14 3 and 4 E-Valve 1 ETS6 Danfoss 3 = orange 4 = Yellow (coil1 96ohm)H15 1 and 2 PT1000 sensor AKS11 for controlling og E-Valve in coling H16 1 and 2 E-Valve 2 ETS6 Danfoss 1 = red 2 = black (coil2 96ohm)H16 3 and 4 E-Valve 2 ETS6 Danfoss 3 = orange 4 = Yellow (coil1 96ohm)H17 1 and 2 PT1000 sensor AKS11 for controlling og E-Valve in coling
Low power side
Graphical display
Sensors
Fan1
Fan2
BMS / CTS
Solid-state
L12
Micro USB
A B
C
L1
L2
L3
L4
L5
L6 L7
L8
L9 L10
L11
L13
L14
Ao1
GND
GND
T1 T110K
T2 T210K
T3 T310K
T4 T410K
T5 T510K
T6 T610K
T7 T710K
T8 T810K
Ao4 Ao3Ao2
GNDAi1
Ai2 Ai3 Ai4 GNDAi5 Ai6 +5V
24V GND Di4 Di5 Di6 GND
Tacho 0-10V GND EC1
Tacho 0-10V GNDEC2
NpN 1
NpN 2 NpN 3
DIP SWITCH
A B GND +24
More fans
ES 2020
A B GND +24
A B GND +24
A B GND +24
A B GND +24
Di1 Di2 Di3
ES 2020 Configuration Example 1: Typical Use of ModBus
ES 2020 includes 4 ModBus connections to ensure an effective ModBus communication both internal and external. The 4 ModBus connections are allocated to different functionalit with different needs for speed and different ylevels of vulnerability.2 ModBus Connections are external - One is master and is used for all sensors thoughout the building. Another one is rused for Building Management Systems / CTS and is Slave. As both these busses may have very long routes (up to 1km) the BaudRate is set to 9600/19200 as recommended by modbus.ORG.The ES 2020 is also equipped with 2 internal Modbus connections where one is used for the graphical display and the other one as internal application bus - in example at the right it is used as bus communication to 2 fans - but could be a lot of other equipment within eg. a Heat Pump or Air Handling Unit. The BaudRate here is at least 19200, but might be as high as 115200 when used for software updates.
The main advantage of having 4 ModBus connections is the reliability of the system - even if for some reason one or both of the extenal ModBus connections are compromised the runit will continue operating.
MV4
Fresh Air
Air discarding Inlet
Outlet
H1
H2CO2
ES 2020 Configuration Example 2: Heat Exchanger with Water Based Heating and Cooling
MV4
Inlet
Outlet
H1
H2CO2
VAV1
VAV2
Fresh Air
Air discarding
ES 2020 Configuration Example 3: Rotary Heat Exchanger with Water Based Heating and Cooling
MV4
Fresh Air
Air discarding Inlet
Outlet
H1
H2CO2 VAV2
ES 2020 Configuration Example 4: Heat Exchanger with Electrical Heating and Cooling
Accessories
LS Control Wireless
Co2T°CRH%
Room sensors
Operating Panel ModBus4 Button, LEDs and USB
Operating PanelTouch with Capasitive ScreenModBus, USB and SD-card.
Wireless Sensors Sensors to be build into yourequipment
10 K NTC
Humidity and temperature inside a unit
Sensors 0-10V and ModBus
Pressure TemperatureCo2Humidity
Visit our web page or call tolet us guide you.