LSSmartConnect LS Control A/S Control platforms Venti lation Heat pump Heat exchan ge Soft ware Heat Supply Hot water App Internet service Low price Easy install Comfort Combi nation LSSmartConnect is our solutionfor connectingyour product onthe internet togive youthe possibility of monitoring, servicingandcontrollingusingan app andPCtools. LSSmartConnect includes ard are for newand h w existingproduct solutions. It alsoincludes oftare s w for programmingthe controller, for monitoring, servicingandadjustingthe finishedproduct solution event over the internet andby use of an p. ap Content of Document 2 Descriptionof SolutionComponents 3 LSSmartConnect Log 4 LSSmartConnect App 5 LSSmartConnect Center 6 LSSmartConnect Config 7 LSSmartConnect GateWay 8 LSSmartConnect ES2020 Platform 9 Describingthe ES2020 PCB 10 The ES2020 Cabinet 11 Overviewof Input / Output Options 12 ConfigurationExample 1: Typical Use of ModBus 13 ConfigurationExample 2: Heat Exchanger withWater Based HeatingandCooling 14 ConfigurationExample 3: Rotary Heat Exchanger withWater BasedHeatingand Cooling 15 ConfigurationExample 4: Heat Exchanger withElectrical Heating andCooling 16 Accessories

Transcript of LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC...

Page 1: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

LS SmartConnect

LS Control A/S

Control platforms

Ventilation Heat

pumpHeatexchange

Software

HeatSupply

Hotwater

AppInternetservice

Lowprice

Easyinstall

Comfort Combination

LS SmartConnect is our solution for connecting your product on the internet to give you the possibility of monitoring, servicing and controlling using an appand PC tools.

LS SmartConnect includes ard are for new and h wexisting product solutions. It also includes oftare s wfor programming the controller, for monitoring, servicing and adjusting the finished product solution event over the internet and by use of an p.ap

Content of Document2 Description of Solution Components

3 LS SmartConnect Log

4 LS SmartConnect App

5 LS SmartConnect Center

6 LS SmartConnect Config

7 LS SmartConnect GateWay

8 LS SmartConnect ES 2020 Platform

9 Describing the ES 2020 PCB

10 The ES 2020 Cabinet

11 Overview of Input / Output Options

12 Configuration Example 1: Typical Use of ModBus

13 Configuration Example 2: Heat Exchanger with Water Based Heating and Cooling

14 Configuration Example 3: Rotary Heat Exchanger with Water Based Heating and Cooling

15 Configuration Example 4: Heat Exchanger with Electrical Heating and Cooling

16 Accessories

Page 2: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

LS SmartConnect Description of Solution Components

LS SmartConnect - Server The server / cloud handles all connected units. Only units with LS Control developed hardware can be connected. Access to connected products is granted through obtained license rights. From the Manufacturers access to several connected units all the way down to each individual user with access to only his own unit (Typically via an pp).a

For any level of customer/user to get access to connected products/units he must be a member of LS SmartConnect. Regardless if product is with integrated internet access such as ES 2020 or the access is obtained via our GateWay and regardles if access is sobtained via pp or PC tools.a

SoftwareLS SmartConnect - Log

The Log software is a technicians tool for accessing a ventilation system, heatpump etc which is connected to the .internet with access to our server. However, the software is also to be used locally typically using the port of a PC.USBTo analye a ventilation system, heat pump etc using the Log z .software demands a log vesion corresponding to the product rneeding to be analyed. This implies you need several log zversions to analye different products. zYou may use Log to set ModBus values and in an advanced Log system you are able to monitor the actual operation.

LS SmartConnect - app App is an application for Smartphones and tablets for the end-user to operate his heat pump / ventilation system.

App is only to be developed for products connecting to the internet and with an integrated Nabto License (such as the 2020-platform) or with internet access through the LS SmartConnect GateWay (offering ModBus to LAN and using Nabto license).

App is developed for both Android and Apple.

LS SmartConnect - Center This monitoring software is a software including more levels and where the Ventilation system, heat pump manufacturer buys a SuperUser licence giving the opportunity to resell sub-licenses for service companies or retailers. The Center monitors all the manufactures customers connected units. ‚

Errors / Status simultaneously displayed for all connected areunits, but only for the level you are licensed for. Giving each level access to exactly the units needed to service and monitor his customers.

LS SmartConnect - ConfigConfiguration tool for LS Control product hardware platform called ES 2020 (Described in this document). The configuration tool gives the possibility of customie znumerous output and input options. This tool has nothing to do with the internet. The objective of this tool is solely for customers to quickly be able to configure hardware to readily be obtained in solution applications without the use of LS Control development department.

LS SmartConnect - GateWay

LS SmartConnect - ES 2020Hardware platform to be configured for

Air handling unitsAir handling units with passive heat pump.

And many more

This hardware box provides the access from a ModBus protocol to a LAN connection to the internet.

To obtain the connection through the GateWay it is necessary to get a little piece of translation software developed to translate the existing ModBus addresses to LAN Connection addresses which can be understood by the LS SmartConnect Server giving access to Log, Center or pp.aTo use the LS SmartConnect GateWay it is mandatory to obtain license for our server.

Nabto connection and internet security.Nabto is a middleware integrated with our SmartConnect hardware products. Nabto provides a secure connection between the users phone/tablet and the SmartConnect ‚

product, using industry standard cryptography. Each product is given a unique device-id which is used by the client to reach it, regardless of dynamic IP addresses. The Nabto middleware provides seamless, direct remote access without firewall or router configuration. The direct Nabto connection ensures the best possible performance with minimal overhead and latency

Hardware

Page 3: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

LS SmartConnect LOG

Provides a graphical overview of the heat pump / ventilation system performance and the possibilities of setting and adjusting the ModBus values to improve the overall performance.

Page 4: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

Vent hastighed

1

The first time the appis startedOr if the user not is logged in.

In case of malfunction at the unit. Alarms

Start screen withcompany logo. Scwitches after 2 seconds

Connectedmodel / type

If user is created and logged in

If there is a user.at the unit

If no available user at the unit

LS SmartConnect App

125320210675

175937221851

308258681780

511639346080

592306484662

755686817020

Add device

Welcome select device

By: LS CONTROL A/S

Status: OK

Temperature: 35°C

Fan speed: 3

Reheet: Off

Settings

Model: XXXXXX

By: LS CONTROL A/S

125320210675

175937221851

308258681780

5116346080

592306484662

755686817020

Add device

Welcome select device

By: LS CONTROL A/S

Create user

Selected device 755686817020

Enter E-Mail

Cancel OK

E - mail

Active user: [email protected]

Back

135320210675

755686817020

Add ID

Delete user

Forgot password

Logout

Devices

Delete Active

Active

User exists

1

Login

Forgot password

Delete user

Selected device: 755686817020

BackUser exists

Options Connection Information

By: LS CONTROL A/S

Ny bruger

Back

Options Connection Information

Fan speed: 3

Temperature: 20,50°C

Reheat

By: LS CONTROL A/S

On/Off

Status: OK

Temperature: 35°C

Fan speed: 3

Reheet: Off

Settings

Model: XXXXXX

By: LS CONTROL A/S

Status: OK

Temperature: 35°C

Fan speed: 3

Reheet: Off

Settings

Model: XXXXXX

By: LS CONTROL A/S

Status: Alarm

Temperature: 700°C

Fan speed: 3

Reheet: Off

Settings

Model: XXXXXX

By: LS CONTROL A/S

Back

By: LS CONTROL A/S

Main filter

Frost

External Filter

Alarms

By: LS CONTROL A/S

off

Back

Options Connection Information

By: LS CONTROL A/S

Modbus information 1

Modbus information 2

Modbus information 3

Modbus information 4

Modbus information 5

Modbus information 6

Modbus information 7

Modbus information 8

Modbus information 9

Modbus information 10

Modbus information 11

Name the unit with your known name:

Active user: [email protected]

Back

Unit name:135320210675

755686817020

Add ID

Delete user

Forgot password

Logout

Delete Active

Active

Options Connection Information

By: LS CONTROL A/S

Name

Name

Active user: [email protected]

Back

135320210675

755686817020

Add ID

Delete user

Forgot password

Logout

Devices

Delete Active

Active

Options Connection Information

By: LS CONTROL A/S

Name

Create user

Selected device 755686817020

Enter E-Mail

Cancel OK

E - mail

Name devicer

Selected device 755686817020

Enter Name

Cancel OK

Name:

Page 5: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

Site 1

All OK

Site 2

Alarm at unit 9

Site 7

All OK

LS SmartConnect Center

Alarm

Alarm

Site AlarmFavorite

PC tool for monitoring several units at the same time.

LS SmartConnect Center

Site 2

___

Site

Dev ID:

Dev ID:

Dev ID:

Dev ID:

Dev ID:

Dev ID:

LS SmartConnect Center

Device: 1122334455 Name: Uint 9 Man: WW2 Cust: Donald Duck, Denmark CPHAlarmlogDevice Status

Site 2

Config

LS SmartConnect Center

Page 6: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

PC tool for configuring the ES 2020 hardware platform.LS SmartConnect Config

Page 7: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

App

Datalogger

Datalog MODBUS®

Existing control system

MODBUS® Protocol— —— —— —— —

LAN

MODBUS®

Power Supply

Datalog stores 120 data entrieswhich is logged every one and a half minute in 150 days. The datacan be shown and analyzed in thedatalogger SoftWare.

Gateway

LS SmartConnect GateWayAn universal box providing a gateway from existing equipment using ModBus protocols to the internet via LAN.

LS SmartConnect GateWay requires customer specific software developed on the basis of data lists, protocols, set points etc.

The LS SmartConnect GateWay provides the possibility of getting existing models of equipment on the internet, opening for the use of LS SmartConnect app and LS SmartConnect Center.

Page 8: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

LS SmartConnect ES 2020 Platform

for

Air handling unitsAir handling units with passive heat pump.

And many more

ES 2020 is a versatile platform.All inputs and outputs can be configured and all functions customized and adjusted using the configuration tool LS SmartConnect Config. This makes the ES 2020 platform very versatile as you may program it for numerous different applications, customizing your product to meet exactly your specific requirements.

However, If you want us to, we still offer to do the programming to customize the ES 2020 to your specific requirements.

ES 2020 has integrated LAN access ensuring your possibilities for getting your equipment on the internet.

When your product is connected to the Internet, user levels can be accessed through LS SmartConnect software, which provides a very unique and future-proof tool to provide customers with the best possible experience and a highly reliable service system.

LS Control A/S

Control platforms

Ventilation Heat

pumpHeatexchange

Software

HeatSupply

Hotwater

AppInternetservice

Lowprice

Easyinstall

Comfort Combination

Page 9: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

Power sideLow power side

What́s inside connections.

Internal flash memory 256Mbit

LANWith Nabto

H1

L12

Micro USBA B

C

Optional

Wireless

Modul for wireless sensors andhome auto-mationstuff..

Build in power - supply 1A / 24V -24VA0,5A for external use.

Build in fuses

Build in fusesL1

L2

L3

L4

L5

L6 L7

L8

L9 L10

L11

L13

L14

H2 H3

H4 H5

H6 H7

H8 H9

H10 H11

H12 H13

H14 H15

H16 H17

T1T110K

T210K

T310K

T410K

T510K

T6 T610K

T7 T710K

T8 T810K

L1 / 4 x analog output + 1 x 10K NTC sensor Aout1 / Aout2 / Aout3 / Aout4 0-10V / T1

L2 / 3 x 10K NTC sensor. ÷ 30 to +130°C T2 / T3 / T4 NTC input can be changed to Digital input in software

Ao2 Ao3 Ao4 Gnd

L3 / 3 x digital input / D1 D2 D31 x analog input / Ai11 x 10K NTC sensor T5

L4 / 3 x 10K NTC sensor. ÷ 30 to +130°C T6 / T7 / T8 NTC input can be changed to Digital input in software

Ai2 Ai3 Ai4 Ai5 Ai6 +5V

L5 / 5 x analog input / Ai2Ai3 / Ai4 / Ai5 / Ai6 Conetcor L7 - 7 = +5V DC output for humidity sensor

24V Di4 Di5 Di6

L6 Power 24V - 0.5A / 12VA // The load 0,5A .total for connected accessories

L7 / 3 x digital input Di4 Di5 Di6

NpN 2 NpN 3

L10 (1-6) 2 x EC motor L10 (7) 1 x NPN output

L11 MOD-BUS 1 L12 2 x NPN output / NPN2 - NPN3

L11 MOD-BUS 2

DIP SWITCH

L13 MOD-BUS 3

L14 MOD-BUS4

L12 Mini USB / connects PC

H1 - 230V PowerSupply Max 16A

H3 / 230V / L - N output (no fuse) after heat.

H2 / 230V / L - N output (no fuse) preheat.

H5 / 230V / L - N output for compressor heat pump.

H4 / Indput from high pressure switch in heat pump systems

H7 / 230V / L - N output Fan 2

H6 / 230V / L - N output Fan 1

H9 / 230V / L - N output

H8 / 230V / L - M - N - output 230V Bypass damper

H11 / 230V / L - N output

H10 / 230V / L - N output Open afterheat Open water cooling

H12 2xPotential-free 5A resistive 24V

H13 H-bridge 100mA nominel 24VDC

H14 E-valve1 12VDC 3W

H15 Pt1000 sensor T9

H16 E-valve2 12VDC 3W

H17 Pt1000 sensor T10

24V/12V or low power

A B GND +24

A B GND +24

A B GND +24

A B GND +24

T2 T3 T4

T5

TachoE1c

TachoE1c

NpN 1

Ground connection:Point for collection of 12 ground connections

Describing the ES 2020 PCB

Page 10: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

The ES 2020 Cabinet

114 mm

210 mm

223 mm

Depth

55 mm17 mm

Connectors All pluggable pcb connectors are with screw terminal.

200 mm

Page 11: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

LS SmartConnect ES 2020 Overview of Input / Output ConnectionsContinued...

Connector Terminal 1 TypeL1 1 Analog out 1 0-10V 10mAL1 2 Analog out 2 0-10V 10mAL1 3 Analog out 3 0-10V 10mAL1 4 Analog out 4 0-10V 10mAL1 5 Gnd 0VL1 6 T1 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L1 7 T1 L2 1 T2 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 2 T2L2 3 T3 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 4 T3L2 5 T4 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L2 6 T4L2 7 Gnd 0VL3 1 Di1 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 2 Di2 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 3 Di3 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L3 4 Gnd 0VL3 5 Analog in 1 0-10V índput / resistance 100K L3 6 T5 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L3 7 T5L4 1 T6 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 2 T6L4 3 T7 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 4 T7L4 5 T8 From -30°C to +70°C 10K NTC ( Maximum 150°*) (12 bit resulution)L4 6 T8L4 7 Gnd 0VL5 1 Analog in 2 0-10V índput / resistance 100K L5 2 Analog in 3 0-10V índput / resistance 100K L5 3 Analog in 4 0-10V índput / resistance 100K L5 4 Gnd 0VL5 5 Analog in 5 0-10V índput / resistance 100K L5 6 Analog in 6 0-10V índput / resistance 100K L5 7 5V ref. supply Load 20mA maximumL6 1 24V supply Load extern power 500mA maximum ( 400mA if including H-Bridge)L6 2 Gnd GND/0Volt for internal powersupply max. 1000mA L7 1 Di4 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 2 Di5 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 3 Di6 Digital input / Switch to Gnd / or if selected NTC 10K (10 bit resulution)L7 4 Gnd 0VL8 1 EC motor 1 Tacho EC motor Tacho feedback (open collector)L8 2 EC motor 1 0-10V 0-10V 10mAL8 3 EC motor 1 gnd 0VL8 4 EC motor 2 Tacho EC motor Tacho feedback (open collector)L8 5 EC motor 2 0-10V 0-10V 10mAL8 6 EC motor 2 gnd 0VL8 7 Npn 1 24V to load / NPN 100mA to Gnd

Connector Terminal 1 TypeL9 1 ModBus 1 - A RTU 9600 / 19200 A=Data +L9 2 ModBus 1 - B RTU 9600 / 19200 A=Data ÷L9 3 ModBus 1 Gnd 0VL9 4 Modbus 1 / +24V Part of total 24V powersupply 500mAL10 1 Npn 2 24V to load / NPN 100mA to GndL10 2 Npn 3 24V to load / NPN 100mA to GndL11 1 ModBus 2 - A RTU 9600 / 19200 A=Data +L11 2 ModBus 2 - B RTU 9600 / 19200 A=Data ÷L11 3 ModBus 2 Gnd 0VL11 4 Modbus 2 / +24V Part of total 24V powersupply 500mAL12 1 MicroUSB USB OTG (On The Go) / USB can be host or deviceL12 1L13 1 ModBus 3 - A RTU 9600 / 19200 A=Data +L13 2 ModBus 3 - B RTU 9600 / 19200 A=Data ÷L13 3 ModBus 3 Gnd 0VL13 4 Modbus 3 / +24V Part of total 24V powersupply 500mAL14 1 ModBus 3 - A RTU 9600 / 19200 A=Data +L14 2 ModBus 3 - B RTU 9600 / 19200 A=Data ÷L14 3 ModBus 3 Gnd 0VL14 4 Modbus 3 / +24V Part of total 24V powersupply 500mADIP Select Select differint programmed softwareLed A LED info Indication processor runningLed B LED info Indication ERROR // Connect LOG og Center for informationLed C LED info Indication Lan OK = Internet connectedLed D LED info Indication Modbus = Modbus running and OK

H1 230V 230V Powersupply (Max. 16A)H2 230V 230V out for preheat / No fuseH3 230V 230V out for afterheat / No fuseH4 Switch in Indput from high pressure switch / Heatpump systems 230V uninsulatedH5 230V 230V out for compressor / No fuseH6 230V 230V Fan 1 (FUSE 5A)H7 230V 230V Fan 2 (FUSE 5A)H8 230V + M L / M / N for 230V on off damper (FUSE 5A)H9 230V 230V out for ? (FUSE 5A)H10 230V 230V out open afterheat (FUSE 5A)H11 230V 230V out open wather cooling (FUSE 5A)

Low Power H12 1 and 2 Switch Switch 5A resitive 24V for ?H12 3 and 4 Switch Switch 5A resitive 24V for ?

H1324Vout for H-bridge damper motor 100mA / Stop will be entered in programs / as power a limit

H14 1 and 2 E-Valve 1 ETS6 Danfoss 1 = red 2 = black (coil2 96ohm)H14 3 and 4 E-Valve 1 ETS6 Danfoss 3 = orange 4 = Yellow (coil1 96ohm)H15 1 and 2 PT1000 sensor AKS11 for controlling og E-Valve in coling H16 1 and 2 E-Valve 2 ETS6 Danfoss 1 = red 2 = black (coil2 96ohm)H16 3 and 4 E-Valve 2 ETS6 Danfoss 3 = orange 4 = Yellow (coil1 96ohm)H17 1 and 2 PT1000 sensor AKS11 for controlling og E-Valve in coling

Page 12: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

Low power side

Graphical display

Sensors

Fan1

Fan2

BMS / CTS

Solid-state

L12

Micro USB

A B

C

L1

L2

L3

L4

L5

L6 L7

L8

L9 L10

L11

L13

L14

Ao1

GND

GND

T1 T110K

T2 T210K

T3 T310K

T4 T410K

T5 T510K

T6 T610K

T7 T710K

T8 T810K

Ao4 Ao3Ao2

GNDAi1

Ai2 Ai3 Ai4 GNDAi5 Ai6 +5V

24V GND Di4 Di5 Di6 GND

Tacho 0-10V GND EC1

Tacho 0-10V GNDEC2

NpN 1

NpN 2 NpN 3

DIP SWITCH

A B GND +24

More fans

ES 2020

A B GND +24

A B GND +24

A B GND +24

A B GND +24

Di1 Di2 Di3

ES 2020 Configuration Example 1: Typical Use of ModBus

ES 2020 includes 4 ModBus connections to ensure an effective ModBus communication both internal and external. The 4 ModBus connections are allocated to different functionalit with different needs for speed and different ylevels of vulnerability.2 ModBus Connections are external - One is master and is used for all sensors thoughout the building. Another one is rused for Building Management Systems / CTS and is Slave. As both these busses may have very long routes (up to 1km) the BaudRate is set to 9600/19200 as recommended by modbus.ORG.The ES 2020 is also equipped with 2 internal Modbus connections where one is used for the graphical display and the other one as internal application bus - in example at the right it is used as bus communication to 2 fans - but could be a lot of other equipment within eg. a Heat Pump or Air Handling Unit. The BaudRate here is at least 19200, but might be as high as 115200 when used for software updates.

The main advantage of having 4 ModBus connections is the reliability of the system - even if for some reason one or both of the extenal ModBus connections are compromised the runit will continue operating.

Page 13: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

MV4

Fresh Air

Air discarding Inlet

Outlet

H1

H2CO2

ES 2020 Configuration Example 2: Heat Exchanger with Water Based Heating and Cooling

Page 14: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

MV4

Inlet

Outlet

H1

H2CO2

VAV1

VAV2

Fresh Air

Air discarding

ES 2020 Configuration Example 3: Rotary Heat Exchanger with Water Based Heating and Cooling

Page 15: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

MV4

Fresh Air

Air discarding Inlet

Outlet

H1

H2CO2 VAV2

ES 2020 Configuration Example 4: Heat Exchanger with Electrical Heating and Cooling

Page 16: LSS maCrtonnect Contento f Document - LS Control · L14 MOD-BUS4 L12 Mini USB / connects PC H1-230VPower SuppyMl ax1 6A H32 / 30VL / - N ouptu t t. aa ( hftee ) fu reons H22 / 30VL

Accessories

LS Control Wireless

Co2T°CRH%

Room sensors

Operating Panel ModBus4 Button, LEDs and USB

Operating PanelTouch with Capasitive ScreenModBus, USB and SD-card.

Wireless Sensors Sensors to be build into yourequipment

10 K NTC

Humidity and temperature inside a unit

Sensors 0-10V and ModBus

Pressure TemperatureCo2Humidity

Visit our web page or call tolet us guide you.