LR600 Auto Levelling Rotary Laser Level USER GUIDE User Guide LR.pdf · your attention to the...
Transcript of LR600 Auto Levelling Rotary Laser Level USER GUIDE User Guide LR.pdf · your attention to the...
2
LR600
Lufkin LR600The LR600 is a professional instrument with an extremely rugged design, enabling precision automatic levelling. Self-levelling range ± 5° horizontal, accuracy 1 mm / 10 m, temperature-resistant sensor system (SLS). Highest reliability is guaranteed through the anti-drift system (ADS): The electronics permanently monitor the measuring process and switch the laser off in the case of any outside interference or disturbance. Adjustable horizontal tilt, easy one-button operation. Includes LRD120 laser detector and remote control unit.
General safety instructionsCaution: Do not look directly into the beam. Lasers must be kept out of reach of children. Never intentionally aim the device at people. This is a quality laser measuring device and is 100% factory adjusted within the stated tolerance. For reasons of product liability, we must also draw
your attention to the following: Regularly check the calibration before use, after transport and after extended periods of storage. We also wish to point out that absolute calibration is only possible in a specialist workshop. Calibration by yourself is only approximate and the accuracy of the calibration will depend on the care with which you proceed.Limited Lifetime Guarantee
Apex Tool Group quality products are Guaranteed against any defect in material or workmanship. Damage caused by abuse, improper use or excessive wear is not covered by this warranty.This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.Claims should be returned, with proof of purchase, to the place of purchase or returned prepaid to the address on back page of this guide. Repaired or replacement goods will be returned at our cost.
Note: This product is a precision instrument that must be handled and treated with care. Avoid shocks and impact. Always keep and carry in the case! Switch all lasers off when not in use. For cleaning, use a soft cloth and glass cleaner.
L a s e r l i g h t !D o n o t s t a r e i n t o t h eb e a m o r v i e w d i r e c t l y
w i t h m a g n i f i e r s .C l a s s 2 / 3 l a s e r
E N 6 0 8 2 5 - 1 : 2 0 0 7 - 1 0
Scan Mode
Slope
3
LR600
Safety Mode
Rotation Speed
Tilt Right
Re-level Control
On Off
Laser Window
Control Panel
Move Scan RightMove Scan Left
Scan Mode
Slope
Tilt Left
4
LR600
Included Accessories:Laser Detector
Close-up of detector controls
Horizontal Levelling Vial
LCD Screen
Detector Window
Volume Control
On / Off
Back Light
Sensitivity Adjustment (high - med - low)
Vertical Levelling Vial
5
LR600
Remote Control
Calibration Panel
Rotation Speed
Re-level Control
On Off
Move Scan Right
Move Scan Left
Scan Mode
Tilt
Tilt Left
Tilt Right
6
LR600
Operation of the LR600Charging the batteries• BeforeusingtheLR600,fullychargethebatteries• Openthebatterycompartment,insertthebatteries
and connect the plugs to the sockets. The plugs fit in the sockets in one position only (see pictures on right). close the battery compartment.
• Connectthebatterycharger/mainsunittoamainssource and plug into the socket. Please only use the charger/mains unit supplied with the device. If a different one is used, the warranty will become void.
• Thedevicecanalsobeoperatedwithstandardalkalinebatteries (4 x type C). Insert the batteries as shown by the installation symbols. Ensure the polarity is correct.
• IftheLEDblinksconstantly,eitherthebatteriesmustbeexchanged or recharged.
Note: Do not expose batteries to excessive heat such as sunshine, fire, etc. Dry batteries must not be recharged. Used batteries must not be disposed of as household waste. Please take them to a collection point for used batteries or for special waste. Ask your local authority for further details.
Pull back rubber weather seal to reveal charging socket
Plugs fit to sockets as shown
7
LR600
Note: If the device is too far off the horizontal (more than 5°), a warning signal will sound and the rotor head will not rotate. In this case, the device must be repositioned on a more level surface.
8
LR600
Note: When the unit is automatically levelled, press the button and the unit will returned to normal operation. When the unit is in safety mode, press this button to exit from the safety mode and enter into the slope setting mode.
10
LR600
Calibration Adjustment1. Switch the LR600 off.2. Hold down the safety mode button and briefly press on/off button
. Keep holding the safety mode button down until the LED’s on the control panel flash 2 times. (Approximately 10 seconds).
3. Calibration adjustments are all made using the calibration panel on the remote control.
X Axis Adjustment 1. Turn the LR600 so that the X axis faces a wall or post (reference surface).2. Activate calibration adjustment mode as described above.3. Press the X / Y button on the remote control twice. The X
LED on the calibrate panel will illuminate as shown on the right. The laser head will start rotating and the X axis can now be adjusted.
4. Adjust the position of the beam using up down buttons on the remote control until the desired position is achieved.
5. To save the new setting press ENT button on the remote control. The X axis LED will now turn off.
Y Axis Adjustment 1. Turn the LR600 so that the Y axis faces a wall or post (reference surface).2. Activate calibration adjustment mode as described above.3. Press the X / Y button on the remote control 3 times. The Y
LED on the calibrate panel will illuminate as shown on the right. The laser head will start rotating and the Y axis can now be adjusted.
4. Adjust the position of the beam using up down buttons on the remote control until the desired position is achieved.
5. To save the new setting press ENT button on the remote control. The Y axis LED will now turn off.
Note: When either the X or Y axis has been adjusted, perform a full calibration check as adjustment of 1 axis can sometimes affect the other axis.
11
LR600
Calibration Adjustment
Z Axis Adjustment 1. Set up the LR600 so that the Z axis (vertical line) aligns with a vertical plumb line.2. Activate calibration adjustment mode as described previously.3. Press the X / Y button on the remote control 3 times. The Z
LED on the calibrate panel will illuminate as shown on the right. The laser head will start rotating and the Z axis can now be adjusted.
4. Adjust the position of the beam using up down buttons on the remote control until the desired position is achieved.
5. To save the new setting press ENT button on the remote control. The Z axis LED will now turn off.
Note When calibration is complete, switch the LR600 off completely before using it further.
12
LR600
LR600 Specifications
Self-levelling range ± 5°
Adjustment speed approx. 30 sec – on entire working angle
Precision Horiz ± 1 mm/10 m - Vert ± 1.5mm/10m
Sensor Electronic levelling device
Horizontal levelling Automatic
Rotation speed 120 RPM (low) & 500 RPM (high)
Remote control Infrared IR
Laser wavelength 635 nm
Laser Class II/III (EN60825-1:2003-10)
Laser output rating < 1 mW
Rechargeable batt. operating time approx. 20 h
Non-rechargeable battery life approx. 30 h, 4 x Typ C
Battery recharging time approx. 14 h
Ambient operating temperature range -10°C ... +50°C
Weight 3 kg
Technical Specifications
LR60
0 Us
er g
uide
rev.1
2041
1
Apex Tool Group Pty Limited519 Nurigong Street, AlburyNSW 2640, AUSTRALIAPh: (02) [email protected]