LPS170 Series 1 of 3VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage...
Transcript of LPS170 Series 1 of 3VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage...
![Page 1: LPS170 Series 1 of 3VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage current: 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power: 110 W convection](https://reader036.fdocuments.in/reader036/viewer/2022071413/610c65104eaa56613e4d87a3/html5/thumbnails/1.jpg)
313
process yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for Business-Critical Continuity
LPS170 Series175 Watts
Special Features• Activepowerfactorcorrection• IECEN61000-3-2compliance• WideRangeAdjustableoutput Remotesenseonmainoutput• Singlewirecurrentsharing• Powerfailandremoteinhibit• Built-inEMIfilter• Lowoutputripple• Overvoltageprotection• Overloadprotection• Thermaloverloadprotection• DCpowergood• 5Vstandbyoutput• 12VAuxoutput• Optionalcover(-Csuffix)
Total Power: 100-175WattsInput Voltage: 85-264VAC 120-300VDC# of Outputs: Single
Electrical Specifications
Safety
InputInputrange: 85-264VAC;120-300VDC
Frequency: 47-63Hz
Inrushcurrent: 38Amax,coldstart@25°C
Efficiency: 75% typical at full load
EMIfilter: FCC Class B conducted CISPR22ClassBconducted EN55022ClassBconducted VDE0878PT3ClassBconducted
PowerFactor: 0.99typical
Safetyground leakagecurrent:
1.0mA@50/60Hz,264VACinput
OutputMaximumpower: 110Wconvection(75Wwithcover)
175Wwith30CFMforcedair (130Wwithcover)
Adjustmentrange: 2:1wideratiominimum
Standbyoutputs: 5V@2Aregulated±5%Hold-uptime: 20ms@175Wloadatnominalline
Overloadprotection: Shortcircuitprotectiononalloutputs. Caseoverloadprotected@110-145%abovepeakrating
Overvoltageprotection: 10%to40%abovenominaloutput
Auxoutput: 12V@1A-5%,+10%
VDE 0805/EN60950 (IEC950)
UL UL1950CB Certificate and reportCSA CSA22.2-234Level3CE Mark(LVD)NEMKO EN60950/EMKO-TUE
•
•••••
Rev. 12.08.08_101LPS170 Series
1 of 3
![Page 2: LPS170 Series 1 of 3VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage current: 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power: 110 W convection](https://reader036.fdocuments.in/reader036/viewer/2022071413/610c65104eaa56613e4d87a3/html5/thumbnails/2.jpg)
Embedded Power for Business-Critical Continuity
313
process yellow
3405
1797
1375
116
2607
652
242
2985
375
240
OrderingInformation
Model Number
Output Voltage
Minimum Load
Maximum Load with Convection
Cooling
Maximum Load with 30CFM
Forced AirPeak Load 1 Regulation 2
Ripple P/P (PARD)3
LPS172 5V(2.5-6V) 0A 22A 35A 38A ±2% 50mV
LPS173 12V(6-12V) 0A 9.1A 15A 16.5A ±2% 120mV
LPS174 15V(12-24V) 0A 7.3A 12A 13.2A ±2% <1%
LPS175 24V(24-54V) 0A 4.5A 7.5A 8.2A ±2% <1%
1. Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2. At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3. Peak-to-peakwith20MHzbandwidthand10µFinparallelwitha0.1µFcapacitoratratedlinevoltageandloadranges.
4.RemoteinhibitresetsOVPlatch.
Note:-Csuffixaddedtothemodelnumberindicatescoveroption.
Rev. 12.08.08_101LPS170 Series
2 of 3
Operatingtemperature: 0°to50°Cambient; derateeachoutputat2.5%perdegreefrom50°to70°C
Lowtemperaturestart: -20°C
Temperaturecoefficient: ±0.4%per°CStoragetemperature: -40°to85°CElectromagnetic susceptibility:
DesignedtomeetIECEN61000-4,-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing5%to95%
Vibration: Threeorthogonalaxes,sweepat1oct/min,5min.dwellatfourmajorresonances0.75Gpeak5Hzto500Hz,operational
MTBFdemonstrated: >550,000hoursatfullloadand25°Cambientconditions
EnvironmentalSpecifications
LogicControlPowerfailure: TTLlogicsignalgoeshigh100-500msecafterV1output;Itgoeslowat
least4msecbeforelossofregulation
Remoteinhibit: Requirescontactclosuretoinhibitoutputs
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremotesenseconnected.Reverseconnectionprotected.
DC-OK: TTLlogicsignalgoeshighaftermainoutputisinregulation.Itgoeslowwhenthereisalossofregulation
PinAssignmentsConnector LPS17x
SK1 PIN1 +12V
PIN2 5VStandby
Pin3 Common
Pin4 V1SWP
PIN5 Common
PIN6 +V1sense
PIN7 Sense common
PIN8 Remoteinhibit
PIN9 DCpowergood
PIN10 POK
SK2 TB-1 COMMON
TB-2 Mainoutput
SK3 PIN1 GROUND
PIN2 LINE
Pin 5 NEUTRAL
MatingConnectorsACInput(SK4): Molex09-50-8051(USA)
Molex09-91-0500(UK)PINS:08-58-0111
DCOutputs(SK3): Molex19141-0058
ControlSignals(SK1):
Molex90142-0010(USA)PINS:90119-2110orAmp:87977-3PINS:87309-8
EmersonNetworkPowerConnectorKit#70-841-016,
includesalloftheabove
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±0.02”(±0.5mm)
3. MountingholesM1andM2shouldbegroundedforEMIpurposes.
4. MountingholeM1issafetygroundconnection.
5. Specificationsareforconvectionratingatfactoryset-tingsat115VACinput,25°Cunlessotherwisestated.
6. Warranty:2year
7. Weight:0.5lbs/0.23kg
![Page 3: LPS170 Series 1 of 3VDE 0878 PT3 Class B conducted Power Factor: 0.99 typical Safety ground leakage current: 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power: 110 W convection](https://reader036.fdocuments.in/reader036/viewer/2022071413/610c65104eaa56613e4d87a3/html5/thumbnails/3.jpg)
Embedded Power for Business-Critical Continuity
313
process yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Rev. 12.08.08_101LPS170 Series
3 of 3MechanicalDrawing
5 3 1
SK4
1 5
6 10
SK1
+ -
SK3
Voltage Adj POT
8.5(216.0)
7.4(188.0)
6.61(168.0)
0.55(14.0)
0.95(24.0)
1.50(38.1)
0.75(19.0)
M3
#6-32
0.88(22.2)
2.50(63.5)
1.07(27.2)
2.11(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
4.25
(108.0)
Americas 5810VanAllenWayCarlsbad,CA92008USATelephone:+17609304600Facsimile: +17609300698
Europe (UK)Waterfront Business ParkMerryHill,DudleyWestMidlands,DY51LXUnitedKingdomTelephone:+44(0)1384842211Facsimile: +44(0)1384843355
Asia (HK)14/F,LuPlaza2WingYipStreetKwunTong,KowloonHongKongTelephone:+85221763333Facsimile: +85221763888 Forglobalcontact,visit:www.powerconversion.com
Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,EmersonNetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmersonNetworkPowerlogoaretrademarksandservicemarksofEmersonElectricCo.©2008EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCoolingRacks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity.
ACPower
Connectivity
DCPower