Low Temperature Plasma Sterilizer...About RENOSEM RENOSEM Co., LTD. is an innovative provider of Low...

7
RENO Low Temperature Plasma Sterilizer Expert in Infection Control www.renosem.com

Transcript of Low Temperature Plasma Sterilizer...About RENOSEM RENOSEM Co., LTD. is an innovative provider of Low...

RENO Low Temperature Plasma Sterilizer

Expert in Infection Control w w w . r e n o s e m . c o m

About RENOSEM

RENOSEM Co., LTD. is an innovative provider of Low Temperature Plasma Sterilizer, infectionprevention, microbial reduction and strives to develop various medical devices using own well-experienced high-tech plasma applications and reliable brand recognition.RENOSEM CO., LTD. has been distributing state-of-the-art medical products through businesspartners globally. RENO Plasma sterilizer prevent patients and users from infection by means of sterilizingsurgical devices 100 percent such as most types of surgical endoscopes, catheters, cannula, etc. Low Temperature Plasma Sterilizer is rapidly emerging as an essential low Temperaturesterilizer which can sterilize humid sensitive and heat sensitive medical devices in OR and CSSDin General hospital as well as Ophthalmology, Biolab, Veterinary clinic [hospital], Dental clinic,and Pharmaceutical Aseptic industry.

Not being satisfied with these achievements, we will focus on our endeavor to come up tocustomer’s needs and market situations.

RENOSEM CO., LTD strives to become the World’s Best Brand in the Healthcare industry byproviding the highest levels of technology, service and standards compliance.

Thanks!

Promise...Supreme quality plasma sterilizer is the promise RENOSEM offers to you

E x p e r t i n I n f e c t i o n C o n t r o l

www.renosem.com·03

E x p e r t i n I n f e c t i o n C o n t r o l

The process is Environmentally Friendly, Safe, Reliable!

( Sterilization chamber )

Abatement Plasma Water vapor(H2O) & Oxygen(O2)HO: hydroxyl radicalHO2: hydroperoxyl radical

HH

O O2H2

+

➔➡H2O2

RadicalPlasma O

O

O

How RENO system works? More Powerful sterilization

·Colored wide touch screen·Display cycle information(estimated cycle time, Temperature, Pressure, etc.)·Customized cycle-mode selection (Short cycle, Long cycle) ·Applicable customized languages (English, German, Spanish, Arabic, French, others)

User Friendly interface

·Spacious rectangular chamber (usable volume more than 90% )·Removable 2 sliding-shelves ·Easy-to-clean chamber wall ·Freely contactable chamber wall ·Solid & acid-proof stainless steel chamber ·Sterilant residual-free using vaporizing filter system

User friendly chamber design

·Easy-to-load single-use cassette·Safe-to-load & waste (Push&Pull)·Reliable quantitative injection system using full vacuum system only·Minimized error system

Easy-to-use sterilization cassette

·Reporting complete cycle information

Thermal Printer

·Data backup using Memory Card or Stick

Universal data acquisition system

·Easy relocation wherever user need

Mobile wheel

·Using DBD(dielectric barrier discharge) plasma technology·Maximizing H2O2 radical effect and sterilization efficacy·Durable & effective plasma(radical) generating system

Radical plasma

·AC plasma discharge·Break down H2O2 gas into Water(H2O2) vapor and Oxygen(O2) ·Durable & Reliable finishing system

Abatement Plasma

·Service diagnostic mode for maintenance and calibration.·Easy-to-diagnosis engineer interface

Maintenance mode

·Biological Incubator for verification of biological test

Peripheral devices

www.renosem.com·05

HOO

HOO

HO

HOO

HO HO

HO

E x p e r t i n I n f e c t i o n C o n t r o l E x p e r t i n I n f e c t i o n C o n t r o l

“More reliable sterilization” “More economic sterilization”

External dimensionWeightDimension Volume& TypeDoseCassetteProcessing temperatureTotal cycle TimePower ConsumptionElectricityControl DisplayPrinterMobility

Chamber

1,020(H)×570(W)×840(D)mm190 Kg300(W)×185(H)×610(D) 34 L, Rectangular4ml (50%)1 cycle/cassetteBelow 55°CAbout 45 min.2.5KVA230V~ Single Phase, 50/60HzMicro ProcessorTouch PanelThermal Printer4 wheels

RENO-S30 Specification

Item RENO-S30

Sterilant

External dimensionWeightDimension Volume& TypeDoseCassetteProcessing temperatureTotal cycle TimePower ConsumptionElectricityControl DisplayPrinterMobility

Chamber

1,310(H)×538(W)×789(D)290 Kg185(H)×300(W)×550(D) 60L, 2×Chamber(30L), Rectangular4ml×2chambers (50%)1cycle/2cassettesBelow 55°CAbout 45 min.2.5KVA230V~, Single Phase, 50/60HzMicro ProcessorTouch PanelThermal Printer4 wheels

RENO-D50 Specification

Item RENO-D50

Sterilant

Color-coded touch screen Sterilant residual-free system Single-use cassette type sterilant Color-coded touch screen Sterilant residual-free system Single-use cassette type sterilant

www.renosem.com·07

RENO-D50RENO-S30

E x p e r t i n I n f e c t i o n C o n t r o l

“More effective sterilization”

Wide TFT LCD touch screen Removable 2 sliding shelves Ergonomic designSingle-use cassette type sterilant

Universal data acquisition system

Complete line of

RENO accessories

◀Sterilization agent

▼Chemical indicator tape

▼ Instrument tray

▼Wrapping non-woven sheet

◀Biological indicator

◀Wrapping pouch

◀Chemical indicator

◀BI Incubator

◀Wrapping tyvekTM pouch

External dimensionWeightDimension Volume& TypeDoseCassetteProcessing temperatureTotal cycle TimePower ConsumptionElectricityControl DisplayPrinterDataMobility

Chamber

1,547(H)×1,220(W)×778(D)mm440 Kg450(W)×400(H)×730(D)mm130L, Rectangular10ml (50%)1cycle/1cassettesBelow 60°CShort cycle: 45min / Long cycle: 65min3.0KVA230V~, Single Phase, 50/60HzMicro ProcessorWide Touch PanelThermal PrinterMemory Card or Stick4 wheels

RENO-S130 Specification

Item RENO-S130

Sterilant

www.renosem.com·09

RENO-S130

E x p e r t i n I n f e c t i o n C o n t r o l E x p e r t i n I n f e c t i o n C o n t r o l

● Cryo-probes ● Dopplers● Electrocautery instruments● Cranial pressure transducer cables● Defibrillator paddles● Endoscopic instruments● Rigid endoscopes ( laryngoscope&blade, arthroscopes , laparoscopes & Trocar

cannula and Trocar sheaths, resectoscope and sheaths, etc.)● Flexible endoscopes (bronchoscopes, hysteroscopes, choledochoscopes, ureteroscopes, cystoscopes, etc. )● Esophageal dilators● Fiberoptic light cables● Laser handpieces, fibers, accessories● Shaver handpieces / Pigmentation handpieces● Metal instruments● Ophthalmic lenses (diagnostic, magnifying)● Patient lead cables● Radiation therapy equipment● Surgical power equipment and batteries (Power drills)● Ultrasound probes● Video cameras and couplers● All devices processed in RENO sterilizer must be within the claims of the sterilizer.

( Flexible & Rigid endoscope )

( Analysis of performance capability )

( Single-through lumen PCD &hollow-type Trocar/cannula )

( Analysis of daily running cycle time )

1. Rapid sterilization cycle time ?

□Yes □No Contribute to rapid turnaround time of instrument and minimized inventory cost

2. Proven strong sterilization efficacy ?

□Yes □No 2mm(inside diameter) x 1.5m(length) PCD(Process challenge device) tool,single-through lumen with an indicator at the closed end of the tube, is used to verify sterility assurance of complex hollow-type instruments.

3. Environmentally friendly byproducts ?

□Yes □No Water vapor & Oxygen only, it’s safe to your staff and patient

4. No plumbing facility required ?

□Yes □No Easy-to-relocate everywhere user need in OR and CSSD

5. Economic operation cost & efficient ?

□Yes □No It relieves the financial burden.

6. Low processing temperature?

□Yes □No it’s less than 55°… and is suitable for most type of endoscope, heat-sensitive instrument.

7. Reliable & Durable system?

□Yes □No it costs less for repairing and maintenance

8. Service activity?

□Yes □No RENO engineer provide support PM(preventive maintenance) , calibration, IQ/OQ.

What are the benefits from your best choice ? What kinds of device can be sterilized in RENO Sterilizer ?

1mm x 12,000mm 1mm x 1,000mm 2mm x 1,500mm

Humid-sensitive materials

Storage after process

Toxicity

Process capability

Can

Can

No

Can’t

Can’t

Noxious odor

Limited capacityusable chamber volumemore than 90%

RENO Plasma System Paracetic Acid System

▲▲

EtO RENO Plasma system

20 times

only 1 times

cycle

Suitable for

minimally invasive

surgery (MIS)

endoscopes

Laparoscope & Trocar cannula Laparoscope & Trocar cannula Bronchoscope

Cystoscope Choledochoscope laryngoscope

Heat sensitive

instruments

Power drills Micro eye surgery instrument

TUR Set Tube Light cords

www.renosem.com·11

Regulatory Approvals

Medical Device directive 93/42/EECISO 13485:2003 Quality Management system-Medical devices-Requirements for regulatory purposes

ISO 9001:2008 Quality management system-design, development and manufacture of low-temperature plasma sterilizer in RENOSEM series.

RENOSEM Co.,Ltd.

RM 303-101, Techno Park Ⅲ, 36-1 Samjeong-Dong, Ojeong-Gu, Bucheon-Shi, Gyeonggi-Do, Korea(#421-742)tel_ +82.32.624.4900 fax_ +82.32.624.4910