Low Smoke Zero Halogen and Control Cable M2XH Cable Structure 1 - Conductor: Electrolytic, stranded,...

24
Cable for Marine Applications Marine Division summit.com/marine LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: [email protected] Low Smoke Zero Halogen

Transcript of Low Smoke Zero Halogen and Control Cable M2XH Cable Structure 1 - Conductor: Electrolytic, stranded,...

Cable for Marine Applications

Marine Division

summit.com/marine

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

621 Time Saver AvenueHarahan, LA 70123

Call Toll Free: (888) 326-5174Email: [email protected]

Low Smoke Zero Halogen

Power and Control Cable

M2XHCable Structure1 - Conductor: Electrolytic, stranded, annealed copper wire. EC 60228 Class 5 (Class 2 and/or tinned on request).

2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE).

3 - Separator: Separating foil or halogen free, bedding compound on request.

4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray.

Production and Test StandardsConstruction ....................................................... IEC 60092 / 353Tests and Material ............................................ IEC 60092 / 350-351-359Flame Retardation ............................................ IEC 60332 / 1, IEC 60332 / 3 Cat AHalogen Content ............................................... IEC 60754 / 1-2Smoke Density ................................................... IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ...................................... -40°C / +90°CMin. Bending Radius (Fixed) .......................... 6 x Overall DiameterRated Voltage ..................................................... 0.6 / 1 kVTest Voltage ......................................................... 3.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations.

2

34

1

(888) 326-5174 2

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

M2XH Power and Control Cable

Part # Sizes mm2 Designation O.D. inches

1758026 2 x 1.5 D-3 0.33

1758027 2 x 2.5 D-4 0.37

1758028 2 x 4 D-6 0.41

1758029 2 x 6 D-10 0.46

3636723 2 x 10 D-16 0.53

1963121 2 x 16 D-26 0.62

1963122 2 x 25 D-41 0.82

1758030 3 x 1.5 T-3 0.35

1758031 3 x 2.5 T-4 0.39

1758032 3 x 4 T-6 0.44

1758033 3 x 6 T-10 0.49

1758034 3 x 10 T-16 0.57

1758035 3 x 16 T-26 0.67

1758036 3 x 25 T-41 0.88

1758037 3 x 35 T-66 0.98

1758038 3 x 50 T-106 1.12

1758039 3 x 70 T-133 1.32

1758040 3 x 95 T-212 1.48

1758041 3 x 120 T-250 1.66

1758042 3 x 150 T-300 1.83

1758043 3 x 185 T-400 2.04

1859977 3 x 240 T-500 2.30

1758044 4 x 1.5 F-3 0.39

1758045 4 x 2.5 F-4 0.43

1758046 4 x 4 F-6 0.49

1758047 4 x 6 F-10 0.54

Part # Sizes mm2 Designation O.D. inches

1758048 4 x 10 F-16 0.63

1758049 4 x 16 F-26 0.73

1758050 4 x 25 F-41 0.97

1758051 4 x 35 F-66 1.08

1758052 4 x 50 F-106 1.26

1758053 4 x 70 F-133 1.46

1758054 4 x 95 F-212 1.67

1758055 4 x 120 F-250 1.85

1758069 4 x 150 F-300 2.04

1758070 4 x 185 F-400 2.30

1758056 7 x 1.5 M-7-3 0.46

1758057 7 x 2.5 M-7-4 0.51

3636722 7 x 4 M-7-6 0.54

1758058 10 x 1.5 M-10-3 0.59

1758059 10 x 2.5 M-10-4 0.66

1971917 12 x 4 M-12-6 0.79

1758060 14 x 1.5 M-14-3 0.64

1758061 14 x 2.5 M-14-4 0.71

3636721 16 x 2.5 M-16-4 0.76

1758062 20 x 1.5 M-20-3 0.71

1758063 20 x 2.5 M-20-4 0.80

1859982 24 x 1.5 M-24-3 0.84

3683670 24 x 2.5 M-24-4 0.94

1758064 30 x 1.5 M-30-3 0.90

1758065 30 x 2.5 M-30-4 1.04

1990092 37 x 1.5 M-37-3 0.97

Product Specifications

summit.com/marine 3

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Shielded Control Cable

M2XCHCable Structure1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request).

2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE).

3 - Shield: Electrolytic, copper-braided shield (90% coverage). M2XCH (EMC) type is wrapped by a copper tape in addition to this shield (100% coverage).

4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray.

Production and Test StandardsConstruction ............................................................................ IEC 60092 / 353Tests and Material ................................................................. IEC 60092 / 350-351-359Flame Retardation ................................................................. IEC 60332 / 1, IEC 60332 / 3 Cat AHalogen Content .................................................................... IEC 60754 / 1-2Smoke Density ........................................................................ IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Shielding Effectiveness (for EMC type) ...........................DIN EN 50147-1Working Temperature ........................................................... -40°C / +90°CMin. Bending Radius (Fixed) ............................................... 8 x Overall DiameterRated Voltage .......................................................................... 0.6 / 1 kVTest Voltage .............................................................................. 3.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations.

12

34

(888) 326-5174 4

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

M2XCHShielded Control Cable

Part # Sizes mm2 Designation O.D. inches

1826901 3 x 2.5 TS-4 0.43

3636718 3 x 4 TS-6 0.48

3636719 4 x 1.5 FS-3 0.43

1826903 4 x 2.5 FS4 0.47

1826902 4 x 4 FS6 0.57

1983712 4 x 25 FS41 1.04

1758016 7 x 1.5 MS-7-3 0.50

1758017 7 x 2.5 MS-7-4 0.57

1758018 10 x 1.5 MS-10-3 0.64

Product Specifications

Part # Sizes mm2 Designation O.D. inches

1758019 10 x 2.5 MS-10-4 0.71

1758020 14 x 1.5 MS-14-3 0.70

1758021 14 x 2.5 MS-14-4 0.77

3636720 16 x 1.5 MS-16-3 0.74

1758022 20 x 1.5 MS-20-3 0.78

1758023 20 x 2.5 MS-20-4 0.85

1758024 30 x 1.5 MS-30-3 0.95

1758025 30 x 2.5 MS-30-4 1.06

summit.com/marine 5

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

M2XCH-VFDCable Structure1 - Conductor: Circular stranded annealed electrolytic copper conductor (Class 5 according to IEC 60228)

2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE).

3 - Filler and Bedding: Halogen-free, flame-retardant, thermoplastic polyolefin-based compound in between the inner sheath and the insulation of the conductor. (HM4/SHF1 - according to IEC 60092-359/360)

4 - Screen: CU/PETP tape (100% coverage). Electrolytic copper braided screen (90% coverage density).

5 - Outer Sheath: Halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1 - according to IEC 60092-359/360)

Production and Test StandardsConstruction ............................................................................ IEC 60092-353 & IEC 60092-360/350Conductor Material................................................................ IEC 60228Insulation Material ................................................................ IEC 60092-351Sheath Material ...................................................................... IEC 60092-360Flame Retardance .................................................................. IEC 60332-1Halogen-Free Properties ..................................................... IEC 60754-1 & IEC 60754-2Low-Smoke Emission ............................................................ IEC 61034-1 & IEC 61034-2Tests ........................................................................................... IEC 60092-353Choice & Installation ............................................................ IEC 60092-352Min. Bending Radius (Fixed) ............................................... 6 x Overall DiameterMin. Bending Radius (during installation) .................... 8 x Overall Diameter

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations.

VFD Cable

12

3

4

5

(888) 326-5174 6

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Product Specifications

M2XCH-VFDVFD Cable

Part # Sizes (mm2) Designation O.D. (inches)

3683672 3 x 16 + 3x6 T-26 VFD 0.90

3683675 3 x 25 + 3x6 T-41 VFD 1.02

* 3 x 35 + 3x6 T-66 VFD 1.12

3695884 3 x 50 + 3x10 T-106 VFD 1.31

* 3 x 70 + 3x16 T-133 VFD 1.45

3695885 3 x 95 + 3x16 T-212 VFD 1.63

* 3 x 120 + 3x25 T-250 VFD 1.86

* 3 x 150 + 3x25 T-300 VFD 2.02

* 3 x 185 + 3x35 T-400 VFD 2.16

* 3 x 240 + 3x50 T-500 VFD 2.41

*Available upon request. Contact Summit’s Marine Division at (888) 326-5174 for more details.

summit.com/marine 7

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

FM2XAHCable Structure1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request).

2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs; pairs laid up concentrically.

3 - Separator: Separating foil below shield.

4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below shield.

5 - Shield: Aluminum tape shield (100% coverage).

6 - Separator: Separating foil above shield.

7 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray.

Production and Test StandardsConstruction ............................................................................ IEC 60092 / 375-376Tests and Material ................................................................. IEC 60092 / 350-351-359Flame Retardation ................................................................. IEC 60332 / 1, IEC 60332 / 3 Cat AHalogen Content .................................................................... IEC 60754 / 1-2Smoke Density ........................................................................ IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ........................................................... -40°C / +90°CMin. Bending Radius (Fixed) ............................................... 8 x Overall DiameterRated Voltage .......................................................................... 60 / 250 VTest Voltage .............................................................................. 1.5 kV

ApplicationUsed as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms.

Overall Shielded Instrumentation Cable

3

4

56

7

1

2

(888) 326-5174 8

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

FM2XAHOverall Shielded Instrumentation Cable

Part # Sizes mm2 Designation O.D. inches

1758013 1 x 2 x 1.5 TPS16-1P 0.37

1758014 1 x 2 x .75 TPS18-1P 0.31

1758015 1 x 2 x .50 TPS20-1P 0.28

Product Specifications

Part # Sizes mm2 Designation O.D. inches

1826904 1 x 2 x 2.5 TPS14-1 0.33

1758068 1 x 3 x 1.5 TTS16-1 0.39

3636717 1 x 3 x 2.5 TTS14-1 0.37

summit.com/marine 9

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

FM2XAAHCable Structure1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request).2- Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs/triads; pairs/triads laid up concentrically.3 - Separator: Separating foil over pairs/triads4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire along each pair/triad.5 - Individual Shield: Aluminum tape shield over each pair/triad and drain-wire bunch (100% coverage).6 - Separator: Separating foil above shield or inner sheath (on request).7 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below overall shield.8 - Overall Shield: Aluminum tape overall shield (100% coverage).9 - Separator: Separating foil over overall shield.10 -Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4/SHF1) – HD 604. Color: Gray.

Production and Test StandardsConstruction ............................................................................ IEC 60092 / 376Tests And Material ................................................................. IEC 60092 / 350-351-359Flame Retardation ................................................................. IEC 60332 / 1, IEC 60332 / 3 Cat AHalogen Content .................................................................... IEC 60754 / 1-2Smoke Density ........................................................................ IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ........................................................... -40°C / +90°CMin. Bending Radius (Fixed) ............................................... 10 x Overall DiameterRated Voltage .......................................................................... 60/250 VTest Voltage .............................................................................. 1.5 kV

ApplicationUsed as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms.

Individually and Overall Shielded Instrumentation Cable

5

3 2

4

9 8 6

10

1

7

(888) 326-5174 10

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

FM2XAAHOverall Shielded Instrumentation Cable

Part # Sizes mm2 Designation O.D. in inches

3636716 2 x 2 x 2.5 TPS14-2P 0.58

1758001 2 x 2 x 1.5 TPS16-2P 0.61

1758002 2 x 2 x .75 TPS18-2P 0.50

1758003 2 x 2 x .50 TPS20-2P 0.46

1758004 4 x 2 x 1.5 TPS16-4P 0.72

1758005 4 x 2 x .75 TPS18-4P 0.58

1758006 4 x 2 x .50 TPS20-4P 0.54

3317874 5 x 2 x .75 TPS18-5P 0.56

1758007 6 x 2 x 1.5 TSP16-6P 0.87

1758008 6 x 2 x .75 TPS18-6P 0.70

Product Specifications

Part # Sizes mm2 Designation O.D. in inches

1758009 6 x 2 x .50 TPS20-6P 0.65

3683671 7 x 2 x 1.5 TPS16-7P 0.76

3713396 7 x 2 x 2.5 TPS14-7P 0.80

1758010 10 x 2 x 1.5 TPS16-10P 1.08

1758011 10 x 2 x .75 TPS18-10P 0.87

1758012 10 x 2 x .50 TPS20-10P 0.80

1758066 12 x 2 x 1.5 TPS16-12P 1.13

1758067 14 x 2 x 1.5 TPS16-14P 1.24

3636714 15 x 2 x .75 TPS18-15P 0.89

3636715 15 x 2 x 1.5 TPS16-15P 1.10

summit.com/marine 11

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

M2XCable Structure1 - Conductor: Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, flame retardant, cross linked, polyolefin compound (HF90). Color: Black (other colors available on request). Double insulation is available on request.

Production and Test StandardsConstruction ....................................................... IEC 60092 / 353Tests And Material ............................................ IEC 60092 / 350-351-359Flame Retardation ............................................ IEC 60332 / 1, IEC 60332 / 3 Cat AHalogen Content ............................................... IEC 60754 / 1-2Smoke Density ................................................... IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ...................................... -40°C / +90°CMin. Bending Radius (Fixed) .......................... 4 x Overall DiameterRated Voltage ..................................................... 0.6 / 1 kVTest Voltage ......................................................... 3.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipment, including marine switchboards. Usable in all conditions in marine environment, such as dry, wet or oily locations.

Single Insulated Conductor Cable

1

2

(888) 326-5174 12

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Product Specifications

M2XSingle Insulated Conductor Cable

Part # Sizes (mm2) Designation O.D. (inches)

* 1 x 0.50 S-1 0.08

* 1 x 0.75 S-2 0.09

* 1 x 1.5 S-3 0.12

* 1 x 2.5 S-4 0.13

* 1 x 4 S-6 0.16

1990090 1 x 6 S-10 0.18

* 1 x 10 S-16 0.22

1990091 1 x 16 S-26 0.26

1826895 1 x 25 S-41 0.34

*Available upon request. Contact Summit’s Marine Division at (888) 326-5174 for more details.

Part # Sizes (mm2) Designation O.D. (inches)

1826896 1 x 35 S-66 0.39

1826897 1 x 50 S-106 0.46

1826898 1 x 70 S-133 0.54

1826899 1 x 95 S-212 0.60

1826900 1 x 120 S-250 0.68

2291899 1 x 150 S-300 0.76

1859983 1 x 185 S-400 0.87

* 1 x 240 S-500 0.98

summit.com/marine 13

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

BU(I) (NEK 606 S13) REDCable Structure1 - Conductor: Electrolytic, stranded, tinned copper wire. IEC 60228 Class 5

2 - Insulation: Halogen free EPR or halogen free HEPR. (All cable to be IEEE-45 color code.)

3 - Separator: Mica tape over conductor

4 - Lay Up: Cores laid up in pair, pairs laid up concentrically

5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along with every pair/triad.

6 - Screen: Electrolytic copper-backed polyester tape screen (100% coverage) over every pair/triad and drain wire

7 - Outer Sheath: SHF2 (SHF MUD on request). Color: Red.

Production and Test StandardsConstruction ................................................................NEK 606 S13, IEC 60092 / 376Tests And Material .....................................................IEC 60092 / 350-351-359Flame Retardation .....................................................IEC 60332 / 1, IEC 60332 / 3 Cat AFire Resistance ............................................................IEC 60331Halogen Content ........................................................IEC 60754 / 1-2Smoke Density ............................................................IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ...............................................-40°C / +90°CMin. Bending Radius (Fixed) ...................................8x Overall DiameterRated Voltage ..............................................................250 VTest Voltage ..................................................................1.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems.

Fire Resistant and Flame Retardant Instrumentation and Telecommunication Cable

(888) 326-5174 14

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

2

4

5

67

1

3

BU(I) (NEK 606 S13) REDFire Resistant, Flame Retardant Instrumentation and Telecommunications Cable

Part # Sizes (mm2) Designation O.D. in inches

3067241 1 x 2x 1.5 BU TPS 16-1 0.34

3208373 2 x 2 x 1.5 BU TPS 16-2 0.57

Product Specifications

summit.com/marine 15

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

BU (NEK 606 P17) REDCable Structure1 - Conductor: -Conductor: Electrolytic, stranded, tinned copper wire. IEC 60228 Class 5.

2 - Insulation: Halogen free EPR. (All cable to be IEEE-45 color code.)

3 - Separator: Mica tape over conductor

4 - Outer Sheath: SHF2. Color: Red.

Production and Test StandardsConstruction ................................................................NEK 606 P17, IEC 60092 / 353Tests and Material .....................................................IEC 60092 / 350-351-359Flame Retardation .....................................................IEC 60332 / 1, IEC 60332 / 3 Cat AFire Resistance ............................................................IEC 60331Halogen Content ........................................................IEC 60754 / 1-2Smoke Density ............................................................IEC 61034 / 1-2 (DIN EN 50268 / 1-2)Working Temperature ...............................................-40°C / +90°CMin. Bending Radius (Fixed) ...................................7x Overall DiameterRated Voltage ..............................................................0.6/1 kVTest Voltage ..................................................................3.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems.

Fire Resistant and Flame Retardant Power Cable

2

4

13

(888) 326-5174 16

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

BU (NEK 606 P17)Fire Resistant and Flame Retardant Power Cable

Part # Sizes (mm2) Designation O.D. (inches)

3067247 7 x 1.5 BU 16/7C 0.60

3067248 19 x 1.5 BU 16/19C 0.96

3067245 3 x 2.5 BU 14/3C 0.49

3208372 4 x 2.5 BU 14/4C 0.54

3331357 7 x 2.5 BU 14/7C 0.66

Product Specifications

Part # Sizes (mm2) Designation O.D. (inches)

3067246 10 x 2.5 BU 14/10C 0.81

3067244 2 x 6 BU 10/2C 0.55

3067243 3 x 6 BU 10/3C 0.59

3067249 4 x 16 BU 6/4C 0.85

3067242 3 x 25 BU 4/4C 0.93

summit.com/marine 17

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

BFOU(I) (NEK 606 S3/S7)Cable Structure1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request).

2 - Separator: Mica tape over conductor

3 - Insulation: Halogen free EPR or Halogen free HEPR

4 - Layup: Cores laid up in pairs/triads, pairs/triads laid up concentrically.

5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along witp every pair/triad

6 - Screen: Electrolytic copper backed polyester tape screen (100% coverage) over every pair/triad and drain wire.

7 - Bedding: Halogen free compound.

8 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ).

9 - Outer Sheath: SHF MUD

Production and Test StandardsConstruction .......................................................NEK 606 S3/S7, IEC 60092/376Tests And Material ............................................ IEC 60092 /350-351-359Flame Retardation ............................................ IEC 60332 /1, IEC 60332 / 3 Cat AFire Resistance ................................................... IEC 60331Halogen Content ............................................... IEC 60754 / 1 - 2Smoke Density ................................................... IEC 61034 / 1-2 ( DIN EN 50268/1-2)Mud Resistance ................................................. IEC 60092 / 359Working Temperature ...................................... -40°C / +90°CMin. Bending Radius (Fixed) .......................... 10 x Overall DiameterRated Voltage ..................................................... 250VTest Voltage ......................................................... 1.5 kV

ApplicationFixed installation cable for signal and communication.

Fire Resistant Instrumentation and Telecommunication Cable

3

45

67

8

9

12

(888) 326-5174 18

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Product Specifications

BFOU(I) (NEK 606 S3/S7)Fire Resistant and Flame Retardant Power Cable

Part # Sizes (mm2) Designation O.D. (inches)

2340970 1 x 2 x 0.75 18/1PR 0.46

2340973 2 x 2 x 0.75 18/2PR 0.67

2340975 4 x 2 x 0.75 18/4PR 0.77

2340972 1 x 2 x 1.5 16/1PR 0.51

2462582 2 x 2 x 1.5 16/2PR 0.77

2340974 4 x 2 x 1.5 16/4PR 0.89

2340976 7 x 2 x 1.5 16/7PR 1.05

Part # Sizes (mm2) Designation O.D. (inches)

2462580 12 x 2 x 1.5 16/12PR 1.39

3713399 18 x 2 x 1 17/18PR 1.50

2340971 1 x 2 x 1 17/1PR 0.47

3713398 1 x 2 x 2.5 14/1PR 0.53

3713397 6 x 2 x 1.5 16/6PR 1.06

3346589 8 x 2 x 1.5 16/8PR 1.29

summit.com/marine 19

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

BFOU (NEK 606 P5/P12)Cable Structure1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request).

2 - Separator: Mica tape over conductor

3 - Insulation: Halogen free EPR or Halogen free HEPR

4 - Bedding: Halogen free compound.

5 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ).

6 - Outer Sheath: SHF MUD

Production and Test StandardsConstruction .......................................................NEK 606 P5/P12, IEC 60092/353Tests And MateriaL ........................................... IEC 60092 /350-351-359Flame Retardation ............................................ IEC 60332 /1, IEC 60332 / 3 Cat AFire Resistance ................................................... IEC 60331Halogen Content ............................................... IEC 60754 / 1 - 2Smoke Density ................................................... IEC 61034 / 1-2 ( DIN EN 50268/1-2)Mud Resistance ................................................. IEC 60092 / 359Working Temperature ...................................... -40°C / +90°CMin. Bending Radius (Fixed) .......................... 8 x Overall DiameterRated Voltage ..................................................... 0.6/1kVTest Voltage ......................................................... 3.5 kV

ApplicationUsed as fixed installation cables in various electromechanical and electronic equipment, emergency and critical systems as well as electric distribution and lighting systems.

Fire Resistant, Flame Retardant, Mud Resistant Power Cable

3

45

61

2

(888) 326-5174 20

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Product Specifications

BFOU (NEK 606 P5/P12)Fire Resistant, Flame Retardant, Mud Resistant Power Cable

Part # Sizes (mm2) Designation O.D. (inches)

2340960 2 x 2.5 14/2C 0.60

2340961 2 x 4 12/2C 0.65

2340962 2 x 6 10/2C 0.69

3683676 2 x 10 8/2C 0.77

3695886 2 x 50 1/0-2C 1.22

2462583 3 x 1.5 16/3C 0.59

2340963 3 x 2.5 14/3C 0.63

2340964 3 x 4 12/3C 0.68

2340965 3 x 6 10/3C 0.72

2340966 3 x 10 8/3C 0.81

Part # Sizes (mm2) Designation O.D. (inches)

2340967 3 x 16 6/3C 0.91

2340968 3 x 25 4/3C 1.07

2340969 3 x 35 2/3C 1.17

2587543 4 x 2.5 14/4C 0.68

3695887 4 x 4 12/4C 0.74

2343009 7 x 1.5 16/7C 0.74

3683667 7 x 2.5 14/7C 0.80

3683666 10 x 2.5 14/10C 0.95

3683668 16 x 1.5 16/16C 1.12

3683669 20 x 2.5 14/20C 1.21

summit.com/marine 21

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

Audio/Visual Signals Sirens/Bells/Horns/ SignalLights Federal SignalBallasts Fluorescent/HID Universal Lighting TechnologiesBanding 316 SS Banding/Buckles Hayata Coated 316 SS Banding/Buckles HayataBatteries Industrial AAA/AA/C/D/Trans/Lantern Rayovac Shipboard Battery Systems / Flooded and Gel Cell Interstate BatteriesCable Glands Marine/Industrial General Duty Gland CMP Hawke Marine / Industrial Class 1, Division 1 & 2 Gland CMP HawkeCable Termination 250V / 600V / High Voltage Panduit Raychem Thomas & BettsCable Tray Steel/Aluminum/Marine Rung B-Line by Eaton Niedax Fiberglass Ladder ChalfantCables / Industrial MV 90/IAC/CLX/Control/ Instrumentation Okonite MV 90/IAC/Control/ Instrumentation/DLO Southwire MV 90/IAC/Control/ Instrumentation/Welding/DLO AIW Control/Instrumentation/Fiber Optic/IAC BeldenCaulking Silicone GE Plastics USCG Approved Fire Stop Caulk Nelson

Chemicals Wire Lube/Cleaners Ideal Lubricants/Cleaners/Sol-vents CRCConduit Rigid Galvanized Steel LTV Shamrock Allied Rigid Stainless Steel Gibson Rigid Aluminum Easco Indalex Plastic Coated Plastibond Sealtight Anaconda Flexible AnacondaConduit Fittings Malleable/Cast/Aluminum/Steel Crouse-Hinds by Eaton Thomas & Betts Cast Alumimum Crouse-Hinds by Eaton Plastic Coated Plastibond Die Cast Steel Crouse-Hinds by EatonConduit Hubs Cast/Steel/Aluminum/SS Crouse-Hinds by Eaton/MyersCord Grips Aluminum Gland Type Grip Remke Nylon Gland Type Grip Kleinhuis (Niedax)Crane Control Crane Brake Parts Eaton (Cutler-Hammer)Distribution Gear Panel Boards/ Power Distribution Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Breakers/Shock & Vibration Eaton (Cutler-Hammer) WestinghouseElectricians’ Supplies Hand Tools Klein Tools IdealEmergency Lighting Battery Operated Teledyne / Big Beam Chloride Dual Lite Excide Safety Systems

Enclosures NEMA/Steel/Aluminum/SS Crouse-Hinds by Eaton Hoffman NEMA/Fiberglass Hoffman

Flashlights Mini/D Cell/Lantern Rayovac Bright StarFuses Glass/250V/600 V/ High Voltage Mersen European Fuses MersenGrounding Systems Rods and Fittings CadweldHeat Shrink Tubing Thick/Thin Wall Tubing Panduit 3M RaychemIndustrial Lighting Fixtures Incandescent/Fluorescent/HID Crouse-Hinds by Eaton Phoenix Fluorescent MobernIndustrial Reelites Electrical/Pneumatic Crouse-Hinds by EatonInstruments Voltage/Amperes/Continuity Fluke GreenleeLabels/Markers/Signs Cable Marking/Safety Marking Panduit Hayata WeidmullerLamps Incandescent/Fluorescent/HID Sylvania Miniature SunrayMotor Control MCC/Enclosed Control Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Control/Parts Eaton (Cutler-Hammer Navy)Navigation Light Panels USCG Approved Custom Panels J - Box

Pin & Sleeve Plug & Receptacle 20 - 400 Amp/Aluminum Crouse-Hinds by Eaton 20 - 400 Amp/Nylon StahlPortable Cord SO/SEOW/Type W/GGC SouthwirePortable Cord Sets & Parts Cord Caps/Cord Sets Woodhead HubbellPortable Lighting Hand Lamps/Class 1 Division 1/Non Hazard Woodhead Portable Cargo Lights Worklights Inc.Safety Switches 30 -1200 Amp./General/Heavy Duty Eaton (Cutler-Hammer)Shipboard Cable Hanger Commercial Cable Hanging Systems R. T. & D Kindorf Victor Commercial and Military Spec Systems R. T. & DShipboard Communication Integrated Ship Communications Federal Signal Sound Powered Phones Hose McCannShipboard General Alarm USCG/Navy Approved Brass Bells Hose McCann General Alarm Panels J-BoxShipboard Light Fixtures Incandescent/Fluorescent/HID/Bronze/Aluminum/SS Phoenix

Incandescent/Fluorescent/HID/Aluminum/SS Aqua Signal L.C. Doane IRLShipboard Navigation Lights USCG Approved/Single/Dual Lamp Aqua SignalShipboard Wiring Devices Switch/Receptacle/Junctions Phoenix

Switch/Receptacle & Related Devices Eaton

Strut Systems Slotted/Angled B-Line by Eaton KindorfTapes Insulating/Bonding/Color Coding 3MTerminal Blocks Din Rail Mount WeidmullerTerminal Tubes 1/2 - 4 Mil Spec. Nylon Dorn 1/2 - 4 Brass/Aluminum/Male/Female Summit Electric SupplyTerminals/Lugs Mechanical/Compression Panduit Burndy Thomas & BettsTimers Electronic/Mechanical Timers TorkTransformers Marine Duty Dry Type 25kVa - 500kVa Eaton (Cutler-Hammer) Westinghouse Dry Type and Oil Filled / SS Clad Olsun Oil Filled/SS Clad Van Tran Control Power Eaton (Cutler-Hammer) Machine Tool Acme Transformer Dry Type Distribution Acme TransformerTransit Barriers/MCTs Multi Diameter/Fire/Water/Gas Rated RoxtecTyraps Wire Securing Devices, Nylon & SS Panduit Hayata Thomas & BettsWire Connectors Wire Nuts Ideal Wing Nuts 3MWiring Devices Switches/Receptacles Cooper Wiring Devices Woodhead

Index of ManufacturersIn addition to wire and cable, Summit’s Marine Division offers a full array of marine electrical products.

(888) 326-5174 22

LOW SMOKE ZERO HALOGEN MARINE WIRE AND CABLE

CIrcular Mills AWG

3 16

4 14

6 12

10 10

16 8

26 6

41 4

66 2

83 1

106 1/0

133 2/0

168 3/0

212 4/0

250 250MCM

350 350MCM

400 400MCM

500 500MCM

U.S. Wire Gauge

Equivalent Metric C.S.A. mm2 AWG or MCM

0.653 19

AWG

0.823 18

1.04 17

1.31 16

1.65 15

2.08 14

2.62 13

3.31 12

4.17 11

5.26 10

6.63 9

8.37 8

10.55 7

13.30 6

16.77 5

21.15 4

26.67 3

33.63 2

42.41 1

53.48 1/0

67.43 2/0

85.03 3/0

107.20 4/0

126.64 250

MCM

154.00 300

202.71 400

253.35 500

304.00 600

354.71 700

405.35 800

506.75 1000

Rated Cross-Section at Metric Systems

mm2

0.75

1.5

2.5

4.0

6.0

10.0

16.0

25.0

35.0

50.0

70.0

95.0

120.0

150.0

185.0

240.0

300.0

400.0

500.0

625.0

summit.com/marine 23

In-house, custom cable armoring is available on request. Call for more information.

Marine Division621 Time Saver Avenue • Harahan, LA 70123 • summit.com/marineCall Toll Free: (888) 326-5174 • Email: [email protected]

Low Smoke, Zero Halogen Marine Cable is In StockFires on board vessels can produce toxic gases and heavy smoke. Our marine low smoke, zero halogen (LSZH) cable can minimize the effects from these dangers.

Save lives, protect your equipment from damage, and meet specifications that require use of LSZH cable. This cable is a low-cost alternative to the military spec cable often used in commercial applications.

• Ship-Set Quantities Available We stock a wide range of material to satisfy your immediate needs.

• Easy Identification Our low smoke, zero halogen cable is color coded to IEEE-45.

• Reduced Time and Labor Costs This ABS-approved cable offers flexible stranding and is easy to strip and terminate.

• Tested and Approved to IEC Standards This LSZH cable meets IEC standards for flame retardation, smoke density and halogen content.

• Top Construction Rating Cable construction is XLPE Insulation/SHF-1 Jacket.

Get fast turn around and low minimums on non-stock items and special constructions.

The Industrial Marine Experts