Low Flow Heaters Low Flow... · 2016-04-27 · Trench Front View Rear View SLF-48 Low Flow Chassis...

16
MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Low Flow Heaters www.sigmaproducts.com Tel: (905) 670-3200 Fax: (905) 670-3822

Transcript of Low Flow Heaters Low Flow... · 2016-04-27 · Trench Front View Rear View SLF-48 Low Flow Chassis...

  • MANUFACTURERS

    OF HYDRONIC

    HEATING

    PRODUCTS

    Low Flow Heaters

    www.sigmaproducts.com Tel: (905) 670-3200 Fax: (905) 670-3822

  • 1

    SLF-MODULAR FAN ONLY UNITS-01..........................................2

    SLF-48 CHASSIS-01 ......................................................................3

    SLF-96 CHASSIS-01 ......................................................................4

    SLF-48E (FULLY EXPOSED).........................................................5

    SLF-96E (FULLY EXPOSED).........................................................6

    SLF-72R (RECESSED) ..................................................................8

    SLF-48 TRENCH-01 (OPPOSITE END CONNECTIONS) .............9

    SLF-48 TRENCH-02 (SAME END CONNECTIONS) ...................10

    SLF-48C (CONCEALED) .............................................................11

    SLF-48TFC (CONCEALED, TOP OUTLET, FRONT INLET).......12

    SPECIFICATIONS........................................................................13

    PERFORMANCE..........................................................................14

    Low Flows

    Table of Contents

    www.sigmaproducts.com

    Rev 3

  • 19 716 "

    4 716 "

    37"

    4 716 "

    54 12 "

    4 716 "

    Single Fan Chassis

    Double Fan Chassis

    SIGMA SLF Low Flow, 'Fan Only' chassis can be installed anywhere additional airlfow is needed (behind wallfin, trenches,bulkheads etc. Each end has an 1/2" nominal (7/8" actual) electrical knockout that allows continuous wiring through units.5/16" Mounting holes are located on the back of the units.

    Motors are 120V, 60Hz, .70A, class H insulation, UL (cUL) E71778.Cycling Thermal Protector, rating 120C.Each individual blower is rated at 150 cfm at 0" static pressure.

    Triple Fan Chassis

    Details of Fan Only Modular Low Flow Chassis

    DO NOT SCALE DRAWING

    SLF-Modular Fan Only Units-01SHEET 1 OF 1

    12/16/2009

    12/16/2009

    12/16/2009RL

    RL

    RL

    SHT SCALE: 1:10

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    LayoutDescription:

  • 7 38 "

    4 38 "

    42 116 "

    45 34 "

    Electrical Box(Can be mounted

    on either side of unit)

    Copper Coil 3/4" SweatConnections at both ends

    (2) Tangential Fans

    ISOMETRICVIEW

    Concealed Low Flow - Chassis Only Unit

    SLF-48 Low Flow Chassis with Opposite End Coil Connections

    DO NOT SCALE DRAWING

    SLF-48 Chassis-01SHEET 1 OF 1

    8/31/2009

    8/31/2009

    8/31/2009RL

    RL

    RL

    SHT SCALE: 1:8

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • 4 38 "

    7 38 "

    82 316 "

    85 1316 "

    Copper Coil 3/4" SweatConnections at both ends

    Electrical Box(Can be mounted

    on either side of unit)(4) Tangential

    Fans

    ISOMETRICVIEW

    Concealed Low Flow - Chassis Only Unit

    Layout Assembly for Low Flow Chassis with Coil

    DO NOT SCALE DRAWING

    SLF-96 Chassis-01SHEET 1 OF 1

    9/8/2009

    9/8/2009

    9/8/2009RL

    RL

    RL

    SHT SCALE: 1:12

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • 47 1516 "

    Coil Connections are 3/4" sweat, 48 fpf Cu/Aland can be easily flipped on site to change handing.

    - Opposite End Connections: SLF-48E-01- Same End Connections: SLF-48E-02

    (2) Tangential Fans

    8"

    4 12 "Louvered

    Outlet

    LouveredInlet

    Left Hand Access Doorto access factory installed

    controls

    Right Hand Access Doorto access field installedcontrols such as valves

    Inlet

    Inlet

    SLF-48E Low FlowsWall / Floor Mounted Exposed

    Low FLows

    Possible Mounting Orientations

    Inlet

    Outlet

    Outlet

    Outlet

    Layout of Exposed SLF-48 Low Flow

    DO NOT SCALE DRAWING

    SLF-48ESHEET 1 OF 1

    12/15/2009

    12/15/2009

    12/15/2009RL

    RL

    RL

    SHT SCALE: 1:8

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • 95 1516 "

    Coil Connections are 3/4" sweat, 48 fpf Cu/Aland can be easily flipped on site to change handing.

    - Opposite End Connections: SLF-48E-01- Same End Connections: SLF-48E-02

    (4) Tangential Fans

    Left Hand Access Doorto access factory installed

    controls

    Right Hand Access Doorto access field installedcontrols such as valves

    8"

    4 12 "Louvered

    Outlet

    LouveredInlet

    SLF-96E Low FlowsWall / Floor Mounted Exposed

    Low FLows

    Possible Mounting Orientations

    Outlet

    Outlet

    Outlet

    Inlet

    Inlet

    Inlet

    Layout of Exposed SLF-96 Low Flow

    DO NOT SCALE DRAWING

    SLF-96ESHEET 1 OF 1

    12/15/2009

    12/15/2009

    12/15/2009RL

    RL

    RL

    SHT SCALE: 1:12

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • Coil Connectionsare 3/4" sweat, 48 fpf Cu/Aland can be easily flipped on siteto change handing.

    - Opposite End Connections: SLF-72R-01- Same End Connections: SLF-72R-02

    FrontView

    (3) Tangential Fans

    74" Cover Length

    71 1516 " Cabinet Length

    RearView

    Left Hand Access Doorto access factory installed

    controls

    Right Hand Access Doorto access field installedcontrols such as valves.

    9 34 "

    4 12 "

    3 34 "34 "

    11 34 "

    SLF-72R Low FlowsRecessed Low FLows

    Possible Mounting Orientations

    Inlet

    Inlet

    InletOutlet

    Outlet

    Outlet

    Details of Recessed SLF-72Low Flow

    DO NOT SCALE DRAWING

    SLF-72R-01SHEET 1 OF 1

    12/16/2009

    12/16/2009

    12/16/2009RL

    RL

    RL

    SHT SCALE: 1:12

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    LayoutDescription:

  • 8"Minimum

    45 34 "

    44 38 "

    37"

    7 716 "

    3/4" SweatConnection on

    each end.

    Control Box

    58 "

    1 38 "1"

    3"

    1" 5 1116 "

    6 716 "

    3"1"

    (5) 5/16" MountingHoles

    Rear View

    4 38 " NON-CompressedHeight

    1" thick open cell foamgasketing can be compressed

    to approx. 1/2"

    Front View

    Trench

    8"Minimum

    SLF-48 Low Flow Chassis with Opposite End Coil Connections

    DO NOT SCALE DRAWING

    SLF-48 Trench Mount Chassis Only-01SHEET 1 OF 1

    12/9/2009

    12/9/2009

    12/9/2009RL

    RL

    RL

    SHT SCALE: 1:8

    WEIGHT: lbs.

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • 8"Minimum

    44 78 "

    42"

    37"

    7"

    Control Box

    3/4" Sweat connections on same end.Coil can be easily flipped on siteto have connections at other end.

    3"

    1"

    58 "

    1 38 "

    1"

    1"

    3"

    5 1116 "

    6 716 "(5) 5/16" MountingHoles

    4 38 " NON-CompressedHeight

    1" thick open cell foamgasketing can be compressed

    to approx. 1/2"

    Trench

    Front View

    Rear View

    8"Minimum

    SLF-48 Low Flow Chassis with Same End Coil Connections

    DO NOT SCALE DRAWING

    SLF-48 Trench Mount Chassis Only-02SHEET 1 OF 1

    12/9/2009

    12/9/2009

    12/9/2009RL

    RL

    RL

    SHT SCALE: 1:8

    WEIGHT: lbs.

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    AssemblyDescription:

  • 47 1516 "

    Coil Connections are 3/4" sweat, 48 fpf Cu/Aland can be easily flipped on site to change handing.

    - Opposite End Connections: SLF-48C-01- Same End Connections: SLF-48C-02

    (2) Tangential Fans

    Left Hand Access Doorto access factory installed

    controls

    Right Hand Access Doorto access field installedcontrols such as valves

    4 12 "

    9 34 "

    MeshInlet

    MeshOutlet

    SLF-48C Low FlowsConcealed Low FLows

    Possible Mounting Orientations

    Inlet

    Inlet

    Inlet

    Inlet

    Outlet

    Outlet

    Outlet

    Outlet

    Details of Concealed SLF-48Low Flow

    DO NOT SCALE DRAWING

    SLF-48C-01SHEET 1 OF 1

    12/16/2009

    12/16/2009

    12/16/2009RL

    RL

    RL

    SHT SCALE: 1:8

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    LayoutDescription:

  • Left Hand Access Doorto access factory installed

    controls

    Right Hand Access Doorto access field installedcontrols such as valves

    47 1516 "

    Coil Connections are 3/4" sweat, 48 fpf Cu/Aland can be easily flipped on site to change handing.

    - Opposite End Connections: SLF-48TFC-01- Same End Connections: SLF-48TFC-02

    4 12 "

    8"

    Mesh Outlet

    Mesh Inlet

    SLF-48TFC Low FlowsConcealed Low FLows with

    Top Outlet / Front Inlet

    Possible Mounting Orientations

    Inlet

    Inlet

    Inlet

    Inlet

    Outlet

    Outlet

    Outlet

    Outlet

    Details of Concealed SLF-48 Low Flow withFront Inlet / Top Outlet

    DO NOT SCALE DRAWING

    SLF-48TFC-01SHEET 1 OF 1

    12/16/2009

    12/16/2009

    12/16/2009RL

    RL

    RL

    SHT SCALE: 1:8

    DWG. NO.A

    SIZE

    TITLE:Drawn by:

    DIMENSIONS ARE IN INCHES UNLESSOTHERWISE SPECIFIEDTOLERANCES: FRACTIONAL 1/32" ANGULAR: 0.5° 2 PLACE DECIMAL: 0.01 3 PLACE DECIMAL: 0.005

    This drawing is the property of SIGMAConvectors Enclosures Corp. and shallnot be reproducedin any form without

    the written consent of SIGMA

    Sigma Corporation

    COMMENTS:

    6185 Kestrel Road, Mississauga, Ont., Canada L5T 1Z2 Tel: (905) 670-3200 Fax: (905) 670-3822

    Date:

    Date:Checked by:

    Approved:Date:

    PROJECTIONTHIRD ANGLE

    LayoutDescription:

  • Low Flow Cabinet Heater SPECIFICATION I. CABINET

    Cabinet is manufactured from 18 Ga Zinc-Ally coated galvanealed steel that meets ASTM A653/A653 CS Type B with coating designation ZF75 with grey primer finish or baked paint finish with colour selected from standard Sigma colours, as required. II. FAN/MOTOR Assembly Motors are 115/1/60, shaded pole with built-in overload protection. Each fan assembly includes two aluminum tangential blowers per motor, directly connected to the fan motor. Fan assembly is statically and dynamically balanced for quiet operation. III. ELEMENT Element will be Copper tube/Aluminum fin construction. The aluminum fins are manufactured with a collar to ensure a mechanical bond once the copper tube is expanded into the fins. Alternate configurations and accessories are available. Contact factory for details

  • LOW FLOW CABINET HEATERS

    Model CFM Delta T MBH GPM WPD MBH Cond lbs/Hr Fan Qty Watts RPM FLA Wht lbs

    10 13.03 2.7 0.19

    20 11.57 1.2 0.05

    30 10.74 0.8 0.02

    40 9.70 0.5 0.01

    10 16.37 3.4 0.27

    20 14.60 1.6 0.07

    30 13.45 1 0.03

    40 12.20 0.7 0.02

    10 27.01 5.6 1.5

    20 25.23 2.7 0.39

    30 23.25 1.6 0.18

    40 20.96 1.1 0.08

    10 33.47 7 2.1

    20 31.28 3.3 0.51

    30 28.78 2 0.22

    40 25.96 1.4 0.11

    31.7 33

    37.3 38.8

    50

    4 60 1550 2 90

    SLF48

    SLF96

    2 60

    175

    250

    350

    500

    15.9 16.6

    200F EWT, 60F EAT Motor Data

    1550 1

    2 psi Steam, 60F EAT

    18.9 19.7

  • Hot Water Correction FactorsLow Flow Unit Heaters

    100 120 140 160 180 200 220 240 260 280 30030 0.518 0.666 0.814 0.963 1.12 1.268 1.408 1.55 1.702 1.85 1.99740 0.439 0.585 0.731 0.878 1.025 1.172 1.317 1.464 1.609 1.755 1.90850 0.361 0.506 0.651 0.796 0.941 1.085 1.231 1.375 1.518 1.663 1.82460 0.286 0.429 0.571 0.715 0.857 1 1.143 1.286 1.429 1.571 1.71770 0.212 0.353 0.494 0.636 0.777 0.918 1.06 1.201 1.342 1.483 1.6380 0.14 0.279 0.419 0.558 0.698 0.837 0.977 1.117 1.257 1.397 1.54590 0.069 0.207 0.345 0.483 0.621 0.759 0.897 1.035 1.173 1.311 1.462100 0 0.137 0.273 0.409 0.546 0.682 0.818 0.955 1.094 1.23 1.371

    Entering AirTemperature F

    Entering Water Temperature F

  • Force Flow Cab Heater

    Steam Correction Factors

    30 40 50 60 70 80 90

    2 1.24 1.16 1.08 1 0.93 0.85 0.78

    5 1.29 1.21 1.13 1.05 0.97 0.9 0.83

    10 1.38 1.29 1.21 1.13 1.06 0.98 0.91

    15 1.44 1.34 1.28 1.19 1.12 1.04 0.97

    20 1.5 1.42 1.33 1.25 1.17 1.1 1.02

    30 1.6 1.51 1.43 1.35 1.27 1.19 1.12

    40 1.68 1.6 1.51 1.43 1.35 1.27 1.19

    50 1.7 1.6 1.58 1.5 1.42 1.34 1.26

    Note: Correction factors to be applied against the 2 psi capacity data at 60F EAT.

    Entering Air Temperature

    Steam Pressure

    SLF Table of ContentsPg 01-SLF-Modular Fan Only Units-01Sheet1Drawing View1Drawing View2Drawing View3Drawing View4Drawing View5Drawing View6

    Pg 02-SLF-48 Chassis-01Sheet1Drawing View3Drawing View4Drawing View5

    Pg 03-SLF-96 Chassis-01Sheet1Drawing View1Drawing View3Drawing View4

    Pg 04-SLF-48ESheet1Drawing View1Drawing View2Drawing View3Drawing View4Drawing View5Drawing View6

    Pg 05-SLF-96ESheet1Drawing View7Drawing View8Drawing View9Drawing View10Drawing View11Drawing View12

    Pg 06-SLF-72R-01Sheet1Drawing View1Drawing View2Drawing View3Drawing View4Drawing View5Drawing View6Drawing View7

    Pg 07-SLF-48 Trench Mount Chassis Only-01Sheet1Drawing View1Drawing View2Drawing View3Drawing View4

    Pg 08-SLF-48 Trench Mount Chassis Only-02Sheet1Drawing View5Drawing View6Drawing View7Drawing View8

    Pg 09-SLF-48C-01Sheet1Drawing View1Drawing View2Drawing View3Drawing View4Drawing View5Drawing View6Drawing View7

    Pg 10-SLF-48TFC-01Sheet1Drawing View1Drawing View2Drawing View3Drawing View4Drawing View5Drawing View6Drawing View7

    Pg 11-Low Flow SPECIFICATION