![Page 1: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/1.jpg)
Long SFA Disease: When a Covered Fracture Resistant Stent is Best
Barry Weinstock, MD, FACC
Florida Heart & Vascular Center
Leesburg Regional Medical Center Leesburg, Florida
![Page 2: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/2.jpg)
Disclosures Speaker’s Bureau: • W.L. Gore & Associates
Consultant: • W.L. Gore & Associates
![Page 3: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/3.jpg)
Limitations of SFA Trials • Balloon angioplasty results extremely poor except for
short, focal stenoses
• Bar is set low -- Easy for new devices to show superiority to “POBA” for moderate length lesions either in randomized trials or in comparison to OPC
• Follow-up is short – typically one year, occasionally two-three years
![Page 4: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/4.jpg)
Viabahn Endoprosthesis 6F/7F Sheath Compatible / 0.018 Wire Compatible
Contoured proximal edge
CARMEDA® Bioactive
Surface (CBAS®
Surface)
Lengths: 2.5, 5, 10, 15,
25 cm
Diameters: 5 mm – 13
mm
Ultra-thin wall ePTFE tube
Unique, durable
bonding film
Polished nitinol
support
![Page 5: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/5.jpg)
Viabahn Clinical Indications
Ø Long lesion lengths, often >15 – 40 cm (or more) Ø Chronic Total Occlusions, often ostial SFA
Ø Calcified vessels, especially in older patients, diabetics, and patients with renal insufficiency / failure
Ø Recent FDA approval for treatment of stent restenosis
Ø Other: Aneurysms and Perforations
![Page 6: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/6.jpg)
Viabahn for long SFA CTO
![Page 7: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/7.jpg)
PTA, Viabahn Stent x 3
![Page 8: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/8.jpg)
0%
20%
40%
60%
80%
100%
0 5 10 15 20 25 Lesion Length (cm)
One
-Yea
r Prim
ary
Pate
ncy
Primary Patency in SFA Stenting
Mul$-‐center, randomized
Mul$-‐center, single arm
Dual-‐center, single arm, EU
Mul$-‐center registry
ZILVER PTX Supera
Absolute VIBRANT
BMS
Durability 200
Durability I
ZILVER PTX Resilient FACT
FAST ZILVER
ASTRON
Trend of randomized BMS studies
![Page 9: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/9.jpg)
Prospec)ve Randomized or Prospec)ve Mul)-‐Center (> 2 sites) SFA studies included. 5, 14, 15, 19-‐30, 32-‐37 Registry studies not included. Patency defini)ons may vary: where Kaplan-‐Meier es)mates with a PSVR of ≥ 2.5 are available, these were used for comparison. P-‐values indicate results of t-‐test on slope of weighted linear regression compared to zero. Note that McQuade et. al, 2010 reported stented length, not lesion-‐length.
![Page 10: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/10.jpg)
Randomized trial: VIABAHN vs. PTFE fem-‐popliteal bypass
DACRON® is a trademark of Invista, Inc., and is licensed to Unifi Inc.
McQuade K, et al. Four-year randomized prospective comparison of percutaneous ePTFE/nitinol self-expanding stent graft versus prosthetic femoral-popliteal bypass in the treatment of superficial femoral artery occlusive disease. Journal of Vascular Surgery 2010;52(3):584-591.
GORE® VIABAHN® Endoprosthesis (n = 50)
ePTFE or Dacron® Bypass (n = 50)
Diameter 5.7 mm 7.4 mm Mean Stented Length 25.6 cm -- TASC II A and B n = 39 n = 35 TASC II C and D n = 11 (22%) n = 15 (30%)
Primary Secondary Primary Secondary
1 Year Patency 72% 83% 76% 86%
2 Year Patency 63% 74% 63% 76%
3 Year Patency 63% 74% 63% 76% 4 Year Patency 59% 74% 58% 71%
![Page 11: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/11.jpg)
Recent Clinical Studies: VIPER Study
VIPER Clinical Study Data: 73% primary patency and 92% secondary patency at 1-year • Prospective, multi-center
• 119 limbs at 12 sites
• Primary patency by duplex (peak systolic velocity ratio (PSVR) < 2.5)
• Average lesion length 19 cm
• 56% Chronic Total Occlusions
11. J Vasc Interv Radiol. 2013;24(2):165-173. (RP1598)
© 2013 W. L. Gore & Associates, Inc.
![Page 12: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/12.jpg)
Device Sizing Patency improved when device not oversized > 20% proximally Device Diameter Patency independent of device diameter (5, 6, 7 mm devices utilized, p = 0.22) Lesion Length Patency independent of lesion length (lesions > 20 cm versus ≤ 20 cm, (P = 0.51)
11. J Vasc Interv Radiol. 2013;24(2):165-173. (RP1598)
Lessons from VIPER
![Page 13: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/13.jpg)
VIASTAR: Primary Patency at 12 Months*
VIABAHN® Endoprosthesis outperformed bare-metal stents in complex lesions—especially those ≥ 20 cm
Randomized Trial vs. BMS N=129 CTO’s: 79% VB 70% BMS
Lammer J, Zeller T, Hausegger KA, et al. Heparin-bonded covered stents versus bare metal stents for complex femoro-popliteal artery lesions: the randomized VIASTAR trial. JACC 2013;62(15):1320-1327.
![Page 14: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/14.jpg)
12-month Data from Multiple studies of VIABAHN Endoprosthesis with Heparin Bioactive Surface*
Author Journal Year No. of
Limbs Lesion Length
(cm) CTOs (%)
Primary Patency
Secondary Patency
LENSVELT
Journal of Vascular Surgery, Vol 56, Iss 1, July 2012, P 118-125
2012 56 18.5 NR 76% 89%
VIPER
Journal of Vascular Interventional Radiology; 24: 165-173
2013 119 19 56% 73% 92%
VIASTAR
Journal of the American College of Cardiology
2013 66 19.0 79% 78% 90%
25 cm Study
Journal of Endovascular Therapy 2014;21:765-774
2014 71 26.5 93% 67% 97%
TOTAL weighted results 312 20.6 72% 73% 92%
![Page 15: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/15.jpg)
Recent Randomized or Prospective Multicenter Trials for Drug-Coated Balloons and the VIABAHN Endoprosthesis*
![Page 16: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/16.jpg)
Recent Randomized or Prospective Multicenter Trials for Drug-Eluting Stents and the VIABAHN Endoprosthesis*
![Page 17: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/17.jpg)
Recent Randomized or Prospective Multicenter Trials for Bare-Metal Stents and the VIABAHN Endoprosthesis*
![Page 18: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/18.jpg)
Recent Randomized or Prospective Multicenter Trials for Atherectomy and the VIABAHN Endoprosthesis*
![Page 19: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/19.jpg)
Conclusions
Ø Viabahn is currently best treatment option for long, complex femoro-popliteal lesions, including chronic total occlusions
Ø Superior results to bare-metal stents and equivalent results to PTFE fem-pop bypass surgery in randomized trials
Ø Only device with length-independent restenosis rate Ø New technologies such as drug coated balloons
offer promise and potential advantages but have yet to be studied in lesions as complex as those treated in multiple Viabahn trials
![Page 20: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/20.jpg)
VIABAHN in Complex SFA Lesions
• Related issues will be addressed in separate lectures
• Management of Viabahn thrombosis
• Use of Viabahn for treatment of bare metal stent restenosis / occlusion
![Page 21: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/21.jpg)
Thank You for your attention Barry Weinstock, MD
![Page 22: Long SFA Disease: When a Covered Fracture Resistant Stent ... NCVH/5-27-Wed/PDFs/1454_Barry... · Long SFA Disease: When a Covered Fracture Resistant Stent is Best BarryWeinstock,MD,FACC!](https://reader031.fdocuments.in/reader031/viewer/2022030411/5a9d9e7f7f8b9a21688d010a/html5/thumbnails/22.jpg)
Long SFA Disease: When a Covered Fracture Resistant Stent is Best
Barry Weinstock, MD, FACC
Florida Heart & Vascular Center
Leesburg Regional Medical Center Leesburg, Florida