Long-Distance Ultrasonic Displacement Sensors
UN Series
Unaffected by the color or material of the target object, ultrasonic sensors achieve long sensing distances using direct reflection.
FEATURES
UNAM30I6103
Sensing range: 100 to 700 mm
Resolution: 0.3 mm
UNAM50I6121/S14
Sensing range: 400 to 2,500 mm
Resolution: 0.6 mm
Resolution: 0.3 to 0.6 mm
High sensing accuracy
Sensing range: 400 to 2,500 mm
Long sensing distance UNAM50I 6121/S14
Distance measurement with the top resolution level in the industry. Direct measurement output of 0–10 Vdc or 4–20 mA.
Long sensing range with high resolution
Because of the ultrasonic sensing method, there is no need to change settings for a new target object color.
Long sensing distances with high accuracy will continue.
No adjustments needed if the color of the target object changes.
Transparent glass substrate Black glass substrate
2
Be sure to use PA5 Series connector cables for connector type sensors.
Sensor side(male)
VA connector side(female)
Sensingmethod Appearance Features Sensing distance Catalog listing
• Built-in compact amplifier• Response time: 60 ms max.• Resolution: 0.3 mm max.• Output: 0 to 10 Vdc
• Built-in compact amplifier• Response time: 100 ms max.• Resolution: 0.3 mm max.• Output: 0 to 10 Vdc
• Response time: 80 ms max.• Resolution: 0.3 mm max.• Output: 4 to 20 mA
• Long sensing distance• Resolution: 0.6 mm max.• Output: 4 to 20 mA
60 to 400 UNDK30U6112
UNDK30U6103
UNAM30I6103
UNAM50I6121/S14
100 to 1000
100 to 700
400 to 2,500
Appearance Power Cable properties Cablelength Catalog listing Lead colors
DC
Oil resistant,bend tolerant,flame resistant,UL2464, EN compliant
2m
5m
2m
5m
PA5-4I SX2MK-EPA5-4I SX5MK-EPA5-4I LX2MK-EPA5-4I LX5MK-E
1: brown, 2: white, 3: blue, 4: black
1: brown, 2: white, 3: blue, 4: black
1: brown, 2: white, 3: blue, 4: black
1: brown, 2: white, 3: blue, 4: black
Note: Use the UNAM50I 6121/S14 in combination with a PA5 series cable with connector (sold separately.)
Ref
lect
ive
anal
og
ou
tpu
t
APPLICATIONS
CATALOG LISTINGS
CABLE WITH CONNECTOR
Glass substrate mapping
PA5 Series cable with connector
Liquid level measurement Tire position detection
3
Blind range (St)Range near the sensor in which the target cannot be detected reliably. In this range, however, there is a chance of detection due to multiple reflection of ultrasonic waves between the sensor and target.
Scanning range far limit (Sde)The far limit of the sensing range.
Sensing range (Sd)The area between the blind range far limit and the scanning range far limit.
Far limit settingA range upper limit setting that can be programmed with Teach-In.
Near limit settingA range lower limit setting that can be programmed that can be with Teach-In.
Minimum setting intervalThe minimum interval between the two settings.
Beam angle
Target
Sensing range (Sd)
Catalog listingScanning range far limitBlind rangeBeam angle (one side)Sonic frequencyTuningSetting upper limitSetting lower limitMinimum setting intervalPowerCurrent consumptionOutputResponse timeRepeatabilityResolutionTemperature driftOperating temperatureOperating humidityIndicator modesHousingProtective structureConnection types
UNDK30U6112 UNDK30U6103 UNAM30I 6103 UNAM50I 6121/S1460 to 400 mm
0 to 60 mm
8˚
400 kHz
60 to 400 mm
60 to 400 mm
-
60 ms max.
0 to 100 mm
15 to 30 Vdc
Teach-In
2% So max.
0 to +60 ˚C
90 % RH max.
* Refer to “Indicator modes” under NOTES FOR USE.
IP67
100 to 1,000 mm
8˚
240 kHz
100 to 1,000 mm
100 to 1,000 mm
-
80 ms max.
0.5 mm max.
0.3 mm max.
2 m preleaded
35 mA max.
0–10 Vdc/ 10–0 Vdc
Polyester Ni-plated brass
150 to 700 mm
100 to 650 mm
50 mm
55 mA max.
4–20 mA / 20–4 mA
80 ms max.
100 to 700 mm 400 to 2,500 mm
0 to 400 mm
8˚
120 kHz
500 to 2,500 mm
400 to 2,400 mm
100 mm
50 mA max.
4–20 mA / 20–4 mA
160 ms max.
1 mm max.
0.6 mm max.
Connector
10˚
230 kHz
Blind range (St)
Sensing distance (So)
Scanning range far limit (Sde)
GLOSSARY
SPECIFICATIONS
4
EXTERNAL DIMENSIONS
UNDK30U61□□ UNAM30I6103
(Unit: mm)
UNAM50I6121/S14
Teach-in button LED
PotentiometerLED
5
Sonic level
Analog output
Target position
Good
Measurement output
Within set range
Small margin
Orange LED lit Orange LED blinking
Insufficient
Orange LED out
–
Red LED lit
Indefinite 4–20 mA or 0–10 Vdc
*Between blind range upper
limit and range near limit setting
1. Indicator modes
* The orange LED could be out for any of the following reasons:• There is no target.• The target is out of range.• The target is within the blind range.• The ultrasonic reflection from the target is too weak.
2. Operating the Teach-In button
Set the scanning range as follows.• Press the button for 2 to 6 seconds until the indicator blinks alternately orange and red.
• Release the button and the indicator will begin to blink red.• Place the target at the 0 Vdc or 4 mA output position and press the button. The indicator begins to blink orange.
• Place the target at the 10 Vdc or 20 mA output position and press the button to complete setup. The interval between the two set points is linearly interpolated.
2.1 Setting a scanning range
Use the Teach-In button for setup. Setup should be completed within five minutes after power-up. The settings are fixed after five minutes to
prevent them from being accidentally changed during regular operation. Even after the power is turned off, the settings are saved.
SENSING AREA (typical)
NOTES FOR USE
(Standard target: 30 x 30 mm2)
Set distance (mm)
Set distance (mm)
Set distance (mm)
Sensor with 300 mm scanning range (Sde)
(Standard target: 100 x 100 mm2)Sensor with 2,500 mm scanning range (Sde)
(Standard target: 30 x 30 mm2)Sensor with 700 mm scanning range (Sde)
There are two ways of setting the scanning range,
depending on the target position.
• When setting 0 Vdc or 4 mA output, place the target near the sensor
4mA0V
Sensing distance
Out
put
20mA10V
6
Distance greater than 2 times the largest range limit setting
Sensor
Sensor
Sensor
Sensor
Distance greater than 4 times the largest range limit setting
0.1 m <
0.1 m <
• Route the cable separately from power lines or though a separate
conduit. Otherwise, induction may cause incorrect operation or
damage.
• If a switching regulator is used for the power supply, connect the
frame ground and ground terminal to ground. If the sensor is used
without grounding, faulty operation may occur due to switching
noise.
• Although the sensor has a miswiring protection circuit, incorrect
wiring involving the input/output terminals may cause damage.
• Diffuse reflection from surrounding objects because of ultrasonic
diffusion or sidelobes may cause incorrect detection. If measurement
is incorrect, consider the following countermeasures: keep the
sensor away from the surrounding objects, use sound-absorbing
materials like sponge, or install sound-insulating barriers.
• When setting 0 Vdc or 4 mA output, place the target far from the sensor.
4mA0V
Sensing distance
Out
put
20mA10V
Target
Sound-insulating barriers
Sensor
3. Handling precautions 4. Influence by diffuse reflection from surrounding objects
5. Wiring precautions
It is possible to revert the settings to the factory defaults by either of
the following methods:
1.
• Press the button for more than 6 seconds until the indicator rapidly
blinks alternately orange and red.
• Release the button, and the indicator will light orange and red at
the same time for 2 seconds. The sensor has been reset to the
factory defaults.
2.
• Set a scanning range without a target. The indicator will rapidly
blink alternately orange and red for 2 seconds. The sensor has
been reset to the factory defaults.
2.2 Factory defaults