Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1...

15
Lockers scii technical

Transcript of Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1...

Page 1: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Lockers

sciitechnical

Page 2: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Lockers

Constantly evolving work environments has seen an increase in the number of organisations adopting an ABW philosophy. As a result, innovative workplace design has led to intelligent furniture solutions, especially in the area of self managed storage systems.

The Schiavello locker range transforms spaces through an adaptable, practical and reliable locker system.

Key, combination or the full electronic management, Schiavello lockers have a solution for every workplace.

Page 3: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Index

Construction

- locker carcass 02

- terminal carcass 02

Construction / Locks

- shrouds and kickers 03

- key locks, combination locks 03

Vecos Electronic Locker System

- introduction 04

- terminals 04

Vecos Hardware

- hubs V1, V2 05

- locks V1, V2 06

- key switch 06

- power supply 06

- UPS - uninterrupted power supply 06

- computer/server requirements 07

- general hardware configuration 07

- software Releezme 08

Doors

- doors, accessories 08

- numbering 08

Product Specifications 11

Please send any Vecos support enquires to:

[email protected]

Page 4: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Constructionlocker carcass / terminal carcass

Locker carcass are constructed from 16mm white laminate with a matching 1mm ABS edge. Available in 2 standard widths, 350mm and 450mm. Carcass height is 1800mm not including the kicker or shroud.

Carcass height -1800mmOverall height -1925mm (with 100mm kicker) -1945mm (with 120mm kicker)

Shroud thickness -25mmKicker option -100mm or 120mm

Locker Carcass

1800mm

500mm350mm 250mm 150mm

Reverse sprung hinges and cable channel come standard with every carcass. Compatible with V1 or V2 locks, Locks and wiring listed separately. Locker 350mm wide internal width 315mmLocker 450mm wide - internal width 415mmLocker 500mm deep - internal depth 445mm

Code: PLC-4A-350 PLC-4A-450

Code: PLC-3A-350 PLC-3A-450

Code: PLC-3B-350 PLC-3B-450

Code: PLC-2A-350 PLC-2A-450

Code: PLC-1A-350 PLC-1A-450

100mm Cable access hole

1800mm

500mm250mm

1300mm

Terminal Carcass There are 2 standard types of terminal carcass, standard and end of run. A standard terminal carcass is similar to a standard locker carcass, however it is only 250mm wide, has only one shelf and is key locked. An end of run terminal carcass should be positioned at the end of a bank of lockers. End of run terminal cupboards are 150mm deep and their widths are varied to suit the locker bank. End of run terminal carcass can be used with single banks or back to back and has a key lock.

Other terminal mountingTerminals can be mounted on walls or lockers. For either option, please contact Prima to confirm the wiring requirements. Locker’s used to house the terminal require access at the back of the locker, enabling the wiring to travel either up or down to the electronics hardware. If there is not a cavity at the back, reducing the depth of the lockers either above or below the terminal to create the cavity is advised.

Standard 4 -locks

Standard 3 - locks

Mixed3 - locks

Standard 2 - locks

Standard1 - lock

EOT - End of trip2 - locks

Standard Terminal

Code: PLC-EOT-350 PLC-EOT-450

Code: PLC-T1-350 PLC-T1-450

Code: PLC-EOR-350 PLC-EOR-450

150mm150mm

Construction Terminal carcass are constructed from 16mm white laminate with a matching 1mm ABS edge. Standard terminal carcass width is 250mm and the height is 1800mm, not including the kicker or shroud.End of run terminal carcass are 150mm deep and widths to suit.

End of run terminalcupboard

Standard terminalcupboard

Cable accessTerminal cupboards house the key switch, UPS and power supply. Cable from these devices are fed out of the carcass through access holes in the top or bottom of the unit. The location of the access hole is dependant on where the electronics will be installed, above or below.

wall mounting plate - stainless steelCode: PWMP

50mm wiring cavity

Terminal

wall

Access hole

Terminal in locker

Wall mounted terminal

End of run Terminal

Page 5: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Shrouds are constructed from 25mm laminate with a 1mm ABS edge strip. Shrouds do not include a back panel unless it is specified. There are 2 types of kickers available, 100mm and 120mm.The 100mm kicker has the feet attached direct to the locker carcass, while the 120mm kicker uses an 18mm board over the feet to assist in levelling the cabinets.

Shrouds and KickersThe kicker allows access to the wiring and is locked in place prior to the completion of the installation. Adjustable levelling feet are supplied with the shroud and fitted on site.

Construction / Locksshrouds & kickers / cam locks

Standard 25mm Shrouds - 100mm kickerDepth 500mm Height 1925mm(special sizes available upon request)Code: PLS-1450 - (350 x 4)+ 50 (2 ends) Code: PLS-1700 - (350 x 4) + 250 + 50 (2 ends) Code: PLS-1800 - (350 x 5) + 50 (2 ends) Code: PLS-1850 - (450 x 4) + 50 (2 ends) Code: PLS-2050 - (350 x 5) + 250 + 50 (2 ends)Code: PLS-2100 - (450 x 4) + 250 + 50 (2 ends)Code: PLS-2150 - (350 x 6) + 50 (2 ends)Code: PLS-2300 - (450 x 5) + 50 (2 ends)Code: PLS-2400 - (350 x 6) + 250 + 50 (2 ends)Code: PLS-2550 - (450 x 5) + 250 + 50 (2 ends)

Solid metal 3/4” cam lock with master key.

Key Cam locks

Solid metal combination cam lock with master key over-ride. 3/4 “ keyed cam lockDual access, key or combination

Combi-Cam locks

Code: PCL-KEY

Code: PCL-COM3

Electronic/Battery Combination Lock - MiniK10MiniK10 electronic cabinet locks feature a master/manager code, one-time-use functionality and up to 10 years battery life. It can be installed vertically or horizontally and either right or left handed. The MiniK10 has three potential password levels and can operate in two different modes, single user or multiple user.

Code: PCL-mk10

Standard 25mm Shrouds - 120mm kickerDepth 500mm Height 1945mm(special sizes available upon request)Code: PLK-1450 - (350 x 4)+ 50 (2 ends) Code: PLK-1700 - (350 x 4) + 250 + 50 (2 ends) Code: PLK-1800 - (350 x 5) + 50 (2 ends) Code: PLK-1850 - (450 x 4) + 50 (2 ends) Code: PLK-2050 - (350 x 5) + 250 + 50 (2 ends)Code: PLK-2100 - (450 x 4) + 250 + 50 (2 ends)Code: PLK-2150 - (350 x 6) + 50 (2 ends)Code: PLK-2300 - (450 x 5) + 50 (2 ends)Code: PLK-2400 - (350 x 6) + 250 + 50 (2 ends)Code: PLK-2550 - (450 x 5) + 250 + 50 (2 ends)

120mm100mm

120mm100mm

Page 6: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Vecos Introduction / Vecos HardwareVecos Introduction / Vecos terminals

Terminals - touch screen

V1 locks - maximum 512 locks per terminal

V2 locks - maximum 256 locks per terminal

Terminals supports a maximum of 7000 users.

RF/ID

ReaderR

F/ID

Rea

der

Touch Screen

147mm

196mm

Code: PLT-WRF

RF/ID

ReaderR

F/ID

Rea

der

Touch Screen

147mm

196mm

Code: PLT-NRF

Vecos electronic locker system (Hardware)

Supported Readers- no reader attached, so keyboard mode activated

- 9600 baud, Any reader that send’s the code at 9600 baud

with CR/LF (Vecos standard)

- BE, The BVE number in the Mifare card

- HW-578, Specific Mifare reader

- iCode 1/2, Specific iCode reader (OMRON V720SHMC73)

- MCR-HID, HID reader using the clock data interface

- TC65, GSM modem attached to the reader port in AT mode

- (SMS), (The SMS sender number is the badge number)

- ATS1192, Weigand

- Weigand 4, 6, 8, 10, 12 bytes, general lengths

- BVE, Reads the BE number of a protected Mifare card/sector

- PRS 5/2 MCR Reader, Pfister reader (ATPS)

- 9600 baud Hex2Dec, converts the 10 hexadecimal characters to a decimal number

- Mc POS, Magna Carta POS reader for payment characters to a decimal number

- 9600NRI, any reader on 9600 baud and the NRI Coin Totalizer

The Vecos electronic locker system is a highly refined, complete locker management solution designed in the Netherlands and sold throughout Europe. The Vecos system is well established as a market leader.

Available in 2 versions, the V1 and the V2. The V1 system relies on the terminals for access to a locker where as a V2 system can access the locker via the terminal or directly at the door.

Both the V1 and the V2 systems feature the push to release mechanism, a USB port and internal lighting. The push to release mechanism safeguards against accidental openings, ensuring personal items are secure.

The V2 system features a card reader and a status indicator light in every door. The card reader is limited in the types of cards it can read. Contact Prima to check the card before confirming the V2 system will work at the door with the clients card.

Keyswitchs come standard with V1 and can be specified for V2. The keyswitch is an overide switch that will unlock all the doors of the locker block and is kept in the terminal cupboard behind key lock access.

Both systems connect across a network and are controlled by the Vecos Smart Access or Releezme software on a windows server. Releezme can also be run from a cloud environment. The Vecos system is very adaptable and can support numerous forms of card readers and other identification methods such as barcode, pin code and NFC, please contact Schiavello with your particular requirement.

Page 7: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Code: PHV2-8

HubsHubs are installed at floor level behind the detachable kicker rail or above the lockers behind a pelmet. The hub connects the locks with the terminal, windows P/C and SmartAccess software.

V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support 32 V1 hubs giving a maximum of 512 locks per terminal.

V2 Hub - 8 outs for a maximum of 24 V2 locks (V2 locks daisy chain, maximum of 6 locks per chain)The terminal can support a maximum of 256 V2 locks.

Code: PHV1-16

Vecos Hardwarehubs / V1 / V2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Coloured wiring ensures cabling is easily identified. All lockers at the same height are given the same coloured wires.

Page 8: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Vecos Hardware V1 & V2 locks / key switch / power supply / UPS

Code: PLPS

240V Enclosed Power Supply

The power supply connects to the Hubs, which then supply the power to the individual locks and the Terminal. Power supplies come in a range of sizes dependant on the number of lockers in the block.

USB PORTOutput5V 600 mA max

LED Lighting

V1 & V2 Locks

The Vecos electronic locks are available in 2 versions, V1 and V2. Both locks feature internal lighting and a USB port. The door catch is designed to release a door and if unopened, will re-engage the lock. The doors hinges are located on the right hand side standard, left side opens. Doors can be ordered for left hand hinges, but must be specified.

V1 locks must be scanned at a terminal and have no status indicator light.The V2 locks includes a card reader with each lock, allowing lockers to be scanned at the door. A status indicator light set is located in the door. V2 locks can read Mifare cards at the door. For any other card type, contact Prima to confirm compatibility.

Door status indicator light with card reader V2

V1

UPS - Uninterrupted Power Supply

A battery backup for power outages,

Code: HLG-240-24A (130 @ V1 locks or 42 @ V2 locks) HLG-320-24A (170 @ V1 locks or 56 @ V2 locks) HLG-600-24A (320 @ V1 locks or 106 @ V2 locks)

Code: UPS

Please note: in the event of a power outage, we recommend all staff to go to their lockers and open them once only, remove what is required for the day and then don’t open them again until the power is back on. Once the UPS runs out of power, it will not be possible to open any lockers.

note: V2 - 5v 600ma supply constant V1 - 5v 100-600ma depending on how many USB sockets are being used off the 1 hub.

Key switch overrideStandard with V1 lockers is a key switch override that when turned, opens all lockers connected to that terminal. The key switch is mounted in the terminal cupboard behind a keyed lock. Key switches can be setup for V2, but must be specified as they do not come standard.

Code: PVKS

Page 9: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

General Hardware Configuration

240V

LAN(TCP/IP)network

Server (windows)

with Smart Access or

Releezme softwarePower Supply

Touch screen

TerminalHub Locks

UPSUninteruptedPower Supply

(battery backup approx 2 hours)

RF/ID

ReaderR

F/ID

Rea

der

VECOS

Cloud with Releezme software

OR

There are many configuration options with the Vecos locks. The below diagram is an example of the basic configuration.

Computer/Server requirements

Vecos’s new software, Releezme, replaces the Smart access software previously offered. Unlike Smart access, Releezme also gives an option for a cloud setup removing the need for an in-house server.If a customer is looking at an on-premise solution, please look to the table for the required hardware and software.

Vecos Hardwarecomputer / server requirements / general hardware configuration

System Component 2000 Lockers 7500 Lockers

Windows operating system

Windows Server 2012 R2 Standard 64 bit

Windows Server 2012 R2 Standard 64 bit

CPU 2 CPU (or 2 vCPU), (4 CPU or 4 vCPU if MS-SQL is on the same machine), minimal 2.4 GHz

Internal memory 4 GB internal memory (8GB if MS-SQL is on the same machine).

8 GB internal memory (16GB if MS-SQL is on the same machine).

2 CPU (or 2 vCPU), (4 CPU or 4 vCPU if MS-SQL is on the same machine), minimal 2.4 GHz

Storage 50GB free disc space (for logging in the database), Database files preferably on separate disks.

100GB free disc space (for logging in the database), Database files preferably on separate disks.

Ethernet connection Gigabit Gigabit

SQL Server MS-SQL 2014 Express (higher recommended if licenses are present).

SQL Server 2014 Standard Edition.

Security certificate Trusted certification chain. Required, but to be acquired by customer.

Other software components

IIS 8.5.NET 4.5.1PowerShell 3.0

IIS 8.5.NET 4.5.1PowerShell 3.0

Trusted certification chain. Required, but to be acquired by customer.

Software components installed/configured as pert of Releezme installation process.

Windows Fabric 1.1 Servicebus for Windows Server v1.1 Redis on Windows.

Windows Fabric 1.1 Servicebus for Windows Server v1.1 Redis on Windows.

Page 10: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

ReleezmeLaunched in 2016, Vecos Releezme software replaces their long running and reliable Smart Access software adding new levels of functionality to Vecos locker systems. Developed for Activity Based Working, Releezme encourages a dynamic use of the workplace, optimising the amount of cabinet space and minimises the amount of time required for locker management. With Releezme, static and dynamic lockers are just the beginning. Releezme allows for multiple user groups and assignment rules that change the way the system operates for different users.

Softwarereleezme

One user may have access to multiple lockers and locker banks, while another might only have access to one locker or locker bank. Combine this functionality with the anti-claiming rules, and the users are able to self manage their lockers within the scope of their configuration. Releezme streamlines the management process while recording every action in the system, allowing management to explore and identify any issue’s, and highlighting the individual users.

PR 0.09

iPR 0.10 1

iPR 0.11 1

iPR 0.12

i

PR 0.13

iPR 0.14 2

iPR 0.15

iPR 0.16 1

i

PR 0.17

iPR 0.18 1

iPR 0.19

iPR 0.20

i

Locker:PR 0.20 x

LOCKER GROUPBedrock showroom

LOCK MODEDynamic (keep)

USB ENABLED

Locker:PR 0.18 x

IN USE BY:Barney Rubble

STARTED05/09/2017 13:37:24

30

Release

occupiedvacant

OCCURRED ON* DESCRIPTION DURATION USER NAME

i

Event log PR 0.16Locker Control > Bedrock Showroom > PR 0.16

Locker Control

LOCATIONBedrock showroom

SECTIONGravel Pit

Installed LBCBedrock showroom

USERS SETUP HANNA BAR....> > >

2017-05-09 12:02:49 Locker unlocked

i 2017-05-09 01:16:27 Locker closed

i 2017-05-09 01:15:58 Locker opened

i 2017-05-09 01:15:31 Locker unlocked

i 2017-05-09 01:14:42 New free locker requested

i 2017-05-09 12:46:24 Locker released

i 2017-05-09 12:07:13 Locker closed

i 2017-05-09 12:06:21 Locker opened

i 2017-05-08 08:02:49 Lock has been detected again

19s

21s

Fred Flinstone

Fred Flinstone

Pebbles Flinstone

Fred Flinstone

*”Occurred on” time has been converted to the logged-in timezone. Click for UIC and/or local time.i

FIRST PREVIOUS NEXT LAST1

iPR 0.06 1

iPR 0.07 1

iPR 0.08

i

PR 0.01

iPR 0.02 1

iPR 0.03 1

iPR 0.04

i

PR 0.05 1

Locker Control

Event log

Page 11: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

DoorsDoors are available in 18mm laminate or 18mm powdercoated MDF. Veneers and metal doors are available upon request. Laminate doors feature a 1mm hard ABS edge. Powdercoated doors can accommodate cutouts and irregular shapes. Vecos doors must have the hinges on the right hand side.Doors for V2 locks also include a status indicator light.

Indicator Light(note: for V2 locks only)

Vents and accessoriesThe standard Prima Vent, 240mm x 85mm, is a powdercoated aluminium vent with 12.7mm x 3.35mm capsule shaped perforations.Names, numbers and paper trays can all be incorporated onto the doors, please contact Schiavello for full details.

Door Type ASolid

Door Type ASolid with Vent

Door Type ASolid with Light

Door Type BLetterbox

Door Type C Mailbox

Doorsdoors / vents and accessories

Door NumberingVinyl stickers- offers the most flexibility with more fonts, colours and sizing options available.Printed aluminium tags -produced to order, offers a wide range of options including font, colour and sizing.Powdercoated - doors can have the number routed into the door at 1mm deep and 40mm high, standard top left corner. The standard Schiavello font is shown below, (please note: other fonts not available, contact Schiavello with your specific request).Plastic numbers are available in a wide range of colours and can be inserted into the routered cutouts, producing a raised number effect.

Page 12: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Vecos V2 with Terminal16 lockers fitted with Vecos V2 electronic locks. Includes terminal and status indicator lights to each door with a standard 25mm laminate shroud.

Vecos V1 with Terminal, vents and numbers.16 lockers fitted with Vecos V1 electronic locks with a terminal. Powdercoated doors with machined numbers and vents to each door.

Page 13: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support
Page 14: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Product specificationsgeneral / construction / finishes / accessories / warranty

General Schiavello Lockers are a fully refined locker system manufactured in Australia by Schiavello. Supplied as a standard laminate carcass and available with a range of configurations and sizes as well as many options on door styles, finishes, lock types and accessories.

There are multiple options for lock types including key, combination, swipe card or the complete network based system, the European VECOS electronic lock management system with swipe card technology and touch screen terminals.

The Vecos locker system is a highly evolved and proven electronic locker management system utilising RFID scanning technologies and network capabilities to allow one central hub for monitoring and maintaining 1000’s of lockers and users.

ConstructionLocker carcass are constructed from 16mm melamine with 2mm hard ABS edges. Cable channelling is machined down either side of the carcass allowing all cables to be concealed. Carcass are supported with adjustable feet hidden behind a 100mm kicker rail.

Available with varying lock types, key, combi-cam, combination electronic (battery), see page 4, or the full Vecos electronic network solution, page 5.

FinishesLaminate carcass with a choice of laminate, metal, powdercoated or veneer doors.

Shrouds and doors can be customised to customer requirements, but are generally either laminate or powdercoated MDF. Standard shroud thickness 25mm, laminate shrouds have a 2mm hard ABS edging.

Veneers and metal doors can be incorporated for premium installations. Laminate doors feature a 1mm hard ABS edging. Doors can incorporate, vents, letter slots, cutouts and machined numbering depending on the finishes. Please see page 8 for full door options.

FeaturesVecos locks feature a unique push release system enabling lockers to be released and if not opened re-locked. Locks feature internal lighting and a USB port. V2 locks include their own card reader allowing lockers to be scanned at the door. The V2 system can be run with or without terminals. The V1 system must have a terminal.

The Vecos system is very adaptable and can support numerous forms of readers and other identification methods such as barcode, pin code and NFC, please contact Schiavello with your particular requirement.

AccessoriesShelves, vents, letter slots, numbering and cutouts can all be incorporated. Please contact Schiavello with your specific requirements.

Warranty

CabinetryVecos Lockers are covered by a standard Schiavello 5 year warranty against faulty materials and workmanship that includes a guarantee to supply parts of all standard components and service for a period of no less than 10 years from date of installation.

ElectronicsVecos electronic hardware is covered by a 12 month warranty on new materials and 3 months on software. Please refer to the Schiavello Vecos Service Level Agreement (SLA) for full details of the services and terms of warranty.

Page 15: Lockers scii - Schiavello Group · windows P/C and SmartAccess software. V1 Hub - 16 outs for 16 V1 locks (each V1 lock connects directly back to the hub) The terminal can support

Melbourne Head Office Schiavello [Vic] Pty Ltd1 Sharps RoadTullamarine VIC Australia 3043 T: 61] 3 9330 8888F: 61] 3 9330 8899

Melbourne Showroom Schiavello [Vic] Pty Ltd31-49 Queensbridge Street Southbank VIC Australia 3006 T: 61] 3 9674 1500F: 61] 3 9764 1650

AdelaideSchiavello [SA] Pty Ltd Ground Floor, 101 Currie Street Adelaide SA Australia 5000T: 08] 8112 2300F: 08] 8231 1419

BrisbaneSchiavello [QLD] Pty Ltd265 Coronation DriveMilton QLD Australia 4064T: 07] 3368 3388F: 07] 3368 2125

CanberraSchiavello [ACT] Pty Ltd2-6 Collie StreetFyshwick ACT Australia 2609 T: 02] 6124 0500F: 02] 6280 4370

PerthSchiavello [WA] Pty Ltd1315 Hay StreetWest Perth WA Australia 6005 T: 08] 9322 6555F: 08] 9322 1337

SydneySchiavello [NSW] Pty Ltd69 Campbell StreetSurry Hills NSW Australia 2010 T: 02] 9211 3311F: 02] 9212 3788

SingaporeSchiavello Singapore Pty Ltd No.1 Magazine road#01-05 Central Mall Singapore 059567T: 65] 6533 8011F: 65] 6533 2811

www.schiavello.comSCH/TVE01-B

Schiavello Group Pty Ltd reserves the right to change any or all details without prior notice. every effort has been made to ensurethe information is accurateat the time of printing.