Loadbearing sheet T4530L905 - rki-bg.com · Loadbearing sheet T4530L905 3 • For insulated roofing...
Transcript of Loadbearing sheet T4530L905 - rki-bg.com · Loadbearing sheet T4530L905 3 • For insulated roofing...
Loadbearing sheet T4530L905Loadbearing sheets are suitable for roof decking, external roof sheeting and intermediate flooring, and they can also beused as formwork for concrete slabs. For the most economical design, use Ruukki’s Poimu roofdimensioning software.
Applications:• Industrial buildings
• Public buildings
• Sports venues
• Office buildings
• Renovation projects
The information on our web site is accurate to the best of our knowledge and understanding. Although every effort has been made to ensureaccuracy, the company cannot accept any responsibility for any direct or indirect damages resulting from possible errors or incorrect
application of the information of this publication. We reserve the right to make changes.
Copyright © 2015 SSAB or its affiliates. All Rights Reserved.
Document printed on 23.06.2015 www.ruukki.com
Properties
The small arrow indicates the side where coating is applied on the sheet.
Note! Loadbearing sheets are delivered with the narrow flange facing up and wide flange facing down, check if you need toturn the sheet for installation.
Product properties Ruukki T4530L905
T = trapezoidal sheet
45 = height class
30 = flange width
L = load bearing profile
905 =modular width
Height: 44 mm
Modular width: 905 mm
Thicknesses available: 0.6, 0.7, 0.9 mm
Minimum length: 500 mm
Maximum length: 15000 mm
Typical span: <3.5 m
Quality control: Factory production control according to EN14782 and EN10901
Material: Hot dip galvanized S350GD+Z steel sheetGalvanized according to EN10346Coilcoated according to EN101691
Tolerances: Profile sheet: EN 14782 and EN 10902
CE marking: According to EN10901
Execution class: EXC1 and EXC2
Loadbearing sheet T4530L905
2
Materials
Thickness Coating Zinc Corrosion classes Steel grade Weight Coloursmm Interior Exterior kg/m2
0.6 Plain galvanized Z275 C1C2 S320 6.51
0.6 Polyester 25 Z275 C1C3 C2C3 S320 6.51 RR20
0.7 Plain galvanized Z275 C1C2 S350 7.59
0.7 Polyester 25 Z275 C1C3 C2C3 S350 7.59 RR20
0.9 Plain galvanized Z275 C1C2 S350 9.76
0.9 Polyester 25 Z275 C1C3 C2C3 S350 9.76 RR20
Protection against corrosion
Environment Coating
Inside buildings in environments with corrosivity category C1, C2 accordingto EN ISO 129442 standard and A1, A2 according to EN 10169 standard
Steel sheets with zinc coating of 100 g/m2and with polyester coating SP 15, thickness15 μm
Interior applications in environments with corrosivity category C1, C2, C3according to EN ISO 129442 standard and A1, A2, A3 according to EN10169 standard
Steel sheets with zinc coating of 275 g/m2and with polyester coating SP 25, thickness25 μm
Corrosivity categories according to EN ISO 129442 standard, examples
Corrosivity category C1:
• Interior – heated building with clean atmospheres, e.g. offices, shops, schools, hotels
Corrosivity category C2:
• Interior – unheated buildings where condensation may occur, e.g. depots, sports halls
Corrosivity category C3:
• Interior – production rooms with high humidity and some air pollution, e.g. foodprocessing plants, laundries, breweries,dairies
• Exterior urban and industrial atmospheres, moderate sulfur dioxide pollution. Coastal areas with low salinity.
Corrosivity category C4:
• Exterior industrial areas and coastal areas with moderate salinity.
Corrosivity categories according to EN 10169 standard (condensation), examples
Corrosivity category A1:
• Interior – office buildings, schools, residential (except kitchens and bathrooms), dry storage buildings
Corrosivity category A2:
• Interior – sports halls, cinemas, theatres, cold stores, supermarkets
Corrosivity category A3:
• Interior – kitchens and bathrooms, food processing (e.g. bakeries), industrial buildings with dry process
Installation
Note! When delivered, the narrow flange of the loadbearing roofing sheet faces upwards in the package, so check if thesheet needs to be turned to be installed correctly.
Loadbearing sheet T4530L905
3
• For insulated roofing structures, the loadbearing sheet needs to be turned, as it is installed with the narrow flangeagainst the support. An exception is the anticondensation coated sheet, which is delivered with the wide flange facingupwards, when semiwarm roof is in question.
• For uninsulated roofs, the sheet is installed as delivered, with the wide flange against the support.
Services & options
Web perforation
Standard perforation grade (withinperforation area) is 15%. Diameter ofperforation holes is 3 mm which arespaced on the basis of equilateral triangle,side equals 7.4 mm.
Due to web perforation of loadbearingtrapezoidal sheets, decrease of strengthparameters takes place.
In order to determine load capacity ofperforated profiles, you are recommendedto use Poimu software, which enablesdimensioning and optimization oftrapezoidal sheets within structure.
Acoustics
When you need reduction for reverberation time, please ask for further information from our sales. Our loadbearing profilesheets are tested with different kinds of roof buildups to meet your needs. We are not limited to only sound absorption, ourexperts are also ready to consult you regarding the roof sound insulation.
Anticondensation
When building cold storage or car shelters, please remember that condensation might be harmful. To avoid this, we canprovide our loadbearing sheets with anticondensation layers.