Loadbank 125, 200 and 250 - Dorman Smith...

36
Loadbank 125, 200 and 250 Panel Boards OVER 130 YEARS OF ELECTRICAL EXCELLENCE

Transcript of Loadbank 125, 200 and 250 - Dorman Smith...

Page 1: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Loadbank 125,200 and 250Panel Boards

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Page 2: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Page 3: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Dorman SmithSwitchgear Limited

Our product range begins with single-pole and neutral distribution board

systems and continues up to custom designed, factory built low-voltage

electrical switchboards for a broad range of commercial, industrial and

retrofit applications.

We continue to build on our extensive technical knowledge and

awareness of customer and market demands, operating conditions and

current regulations.

This breadth of experience supports the development and manufacturing

techniques of our electrical products to exceed the industry standards.

1

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

With over 130 years of experience in switchgear design andproduction Dorman Smith Switchgear Limited continues to providehigh quality equipment for low-voltage electrical distribution andcircuit protection.

IndexContent Page No

Introduction to Dorman Smith Switchgear Limited 1

Loadbank 125 Key Features 2-3

Loadbank 125 Panel Boards & Accessories 4-5

Loadbank 125 Outgoing Devices & TVSS 6

Loadbank 125 Meters & Current Transformers 7-8

Loadbank 200 Key Features 10-11

Loadbank 200 Panel Boards & Accessories 12

Loadbank 200 Outgoing Devices 13

Loadbank 200 Add on Enclosures 14

Loadbank 200 Meters, Current Transformers & TVSS 15-18

Loadbank 250 Key Features 20-21

Loadbank 250 Panel Boards & Accessories 22-24

Loadbank 250 Outgoing Devices 25-26

Loadbank 250 Add on Enclosures 27

Loadbank 250 Meters, Current Transformers & TVSS 28-33

Page 4: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Key Features

The busbars are ASTA certified with a short-circuit withstand rating of 25kA for 1 secondfor the 250A panel board and 25kA for 3seconds for the 400A panel board.

Form 3 is standard on the 400A panel boardand this can be achieved for the 250A panelboard with terminal shields fitted to theoutgoing devices.

The Loadbank 125 offers an uncomplicatedsolution for power distribution forcommercial and industrial applications withthe availability of add-on enclosures such asmetering enclosures and service centreswhich match the dimensional profile of thepanel board.

Outgoing devices consist of a single framesize utilising the Loadline YA2 frame MCCB upto 125A which are a cost effective option forcircuit protection.

Standard finish is epoxy powder coating inlight grey RAL 7035.

2

Outgoing WaysOur 250A panel boards are availablewith 6, 8 or 12 triple-pole outgoing waysand the 400A boards are available with6, 8, 12 or 16 triple-pole outgoing waysfor greater flexibility in design.

Incoming OptionsOur Loadbank 125 panel boards can havea variety of incoming options including;MCCB, switch disconnector or directconnection.

PAGE 6 PAGES 4-5

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

This panel board range features busbarratings of 250A and 400A, outgoingdevices up to 125A, seven panel board sizeoptions, surge protection mounted integralto the board and options to meterincoming and outgoing supply.

Loadbank 125250A and 400A MCCBPanel Boards - Outgoingdevices up to 125A

BusbarThe Loadbank 125 panel boards havean ASTA certified busbars with a shortcircuit rating of 25kA for 1 second forthe 250A boards and 25kA for 3seconds for the 400A boards.

PAGES 4-5

CompliancePanel Boards EN 61439-2MCCBs EN 60947-2

Page 5: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

3

Modular OptionsThis range has a common width anddepth for the panel board and any add-on enclosures ensuring ease for usingthis range in panel building applications.

Outgoing DevicesBoth the 250A and the 400A share thesame outgoing device type which is ourLoadline YA2 frame MCCB. This isavailable as single-pole fixed breakers orthree and four-pole adjustable breakersfrom 16A to 125A in 25kA. There are also arange of accessories for the Loadline YA2MCCBs including; shunt trips, auxiliariesand UVRs.

FormThe 400A panel board is a Form 3aas standard.

Modular DevicesThere is a range of modular devicesavailable for use with the Loadbank 125system including; metering, contactors,surge protection and timers.

PAGES 6-8

PAGES 4-5

PAGE 6

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Add-on EnclosuresPanel building options for the Loadbank125 range include; cable spreader box foradditional cabling room, meteringhousing for incoming and outgoing DIN-rail meters, service centre and additionalenclosure to house one Loadline YA3MCCB up to 250A as an outgoing device.

PAGES 4-5

Surge ProtectionA Type II Class II surge protection devicecan be internally installed in theLoadbank 125 panel boards. This devicecomes with a remote indicator panelwhich fits in a knockout in the frontshield for easy surge protectionmonitoring. A Type I Class I device canalso be used with this range viainstallation in a service centre.

PAGE 6

MeteringBy using the add-on metering enclosuresthis panel board system can be easilymetered for incoming and outgoingcircuits. The add-on metering enclosurecan also house the current transformersand there are wiring looms available forthis range pre-cut to the required length.

PAGE 7-8

Page 6: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel Boards250A Form 3a 25kA for 1 secondMain features• ASTA Certified busbars rated at 25kA for 1 second• Form 3a as standard• IP4X Ingress Protection rating• Accepts YA2 frame MCCB up to 125A as outgoing devices• Enclosure width is 700mm and depth 190mm. Height as per the table below.• Incoming device is fitted integral to the board

4

250A Panel Board Add-on unitsDescription Height

(mm)Weight(kg)

Product Code

Cable spreader box 270 8.3 PBYA2CSBService centre for 24 x 1-pole ways 270 9 PBYA2SC24YB3 MCCB outgoing housing up to 250A 450 15 PBYA2OGMeter housing 450 12 PBYA2MB

Loadbank 125MCCB Panel Boards250A Form 3a 25kA for 1 second

250A Panel Board AccessoriesDevice Type Product CodeYB3 3-pole incoming terminal shroud YB3TS3PYB3 4-pole incoming terminal shroud YB3TS4PYB3 3-pole and 4-pole dolly locking device YBDL1YA2 1-pole outgoing terminal shroud YA2TS1PYA2 3-pole outgoing terminal shroud YA2TS3PYA2 1-pole dolly locking device Y2DLYA2 3-pole dolly locking device YADL1Cylinder door lock with keys DBXCLDoor padlock device DBXPL3-pole blanking plate LBYA2BP3PIncoming connection Kit for 4-pole device PB4PNC250Spare neutral / earth bar clamps for cables up to 70mm² PBYA2NA

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

OutgoingWays

IncomingDevice Type

OutgoingDevice Type

Height(mm)

Weight(kg)

Product Code

6 YB3 Frame YA2 Frame 904 36 PB206YA8 YB3 Frame YA2 Frame 994 39 PB208YA12 YB3 Frame YA2 Frame 1174 47 PB212YA

Device Type Current Rating(A)

Icu (kA) No ofPoles

Product Code

Switch Disconnector 250 N/A 3 YB3B3P250DMCCB 160 25 3 YB3N3P160TMCCB 200 25 3 YB3N3P200TMCCB 250 25 3 YB3N3P250TSwitch Disconnector 250 N/A 4 YB3B4P250DMCCB 160 25 4 YB3N4P160TMCCB 200 25 4 YB3N4P200TMCCB 250 25 4 YB3N4P250T

250A Panel Board Incoming Device OptionsYB3 Frame MCCB• Exceeds the requirements of EN 60947-2• MCCBs have adjustable overload and instantaneous trips, except switch disconnector• Overload adjusts to 1 x In, 0.8 x In and 0.63 x In• Standard cable termination is 95mm² and maximum 150mm² using M8 reduced palm width lugs• Cable clamps available for YB3 MCCBs for maximum cable termination of 120mm²• Four-pole incoming devices require additional connection kit of PB4PNC250

Page 7: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

5

Loadbank 125MCCB Panel Boards400A Form 3a 25kA

for 3 seconds

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel Boards400A Form 3a 25kA for 3 secondsMain features• ASTA Certified busbars rated at 25kA for 3 seconds• Form 3a as standard• IP4X Ingress Protection rating• Accepts YA2 MCCB up to 125A as outgoing devices• Enclosure width is 700mm and depth 190mm. Heights as per the table below.• Incoming device is fitted integral to the board

Description Height(mm)

Weight(kg)

Product Code

Cable spreader box 270 8.3 PBYA2CSBService centre for 24 x 1-pole ways 270 9 PBYA2SC24YB3 MCCB outgoing housing up to 250A 450 15 PBYA2OGMeter Housing 450 12 PBYA2MB

400A Panel Board AccessoriesDevice Type Product CodeYA5 3-pole incoming terminal shroud for spread type extensionterminals and cable lugs

YA5TS3P

YA5 4-pole incoming terminal shroud for spread type extensionterminals and cable lugs

YA5TS4P

YA5 3-pole spread type extension terminals YA5XT3PYA5 4-pole spread type extension terminals YA5XT4PYA2 1-pole outgoing terminal shroud YA2TS1PYA2 3-pole outgoing terminal shroud YA2TS3PYA2 1-pole dolly locking device Y2DLYA2 3-pole dolly locking device YADL1Cylinder door lock with keys DBXCLDoor padlock device DBXPL3-pole blanking plate LBYA2BP3PIncoming connection kit for 4-pole device PB4PNC400

OutgoingWays

IncomingDevice Type

OutgoingDevice Type

Height(mm)

Weight(kg)

Product Code

6 YA5 Frame YA2 Frame 1084 45 PB406YA8 YA5 Frame YA2 Frame 1174 48 PB408YA12 YA5 Frame YA2 Frame 1354 56 PB412YA16 YA5 Frame YA2 Frame 1534 65 PB416YA

Device Type Current Rating(A)

Icu (kA) No ofPoles

Product Code

Switch Disconnector 400 N/A 3 YA5B3P400DMCCB 250 25 3 YA5N3P250TMCCB 400 25 3 YA5N3P400TSwitch Disconnector 400 N/A 4 YA5B4P400DMCCB 250 25 4 YA5N4P250TMCCB 400 25 4 YA5N4P400TDirect Connection 400 N/A N/A PBYA2DC4

400A Panel Board Incoming Device OptionsYA5 Frame MCCB• Exceeds the requirements for EN 60947-2• MCCBs have adjustable overload and instantaneous trips, except switch disconnector• Overload adjusts to 1 x In, 0.8 x In and 0.63 x In• Standard cable termination is 95mm² and maximum 185mm² using M10 reduced palm width lugs• Four-pole incoming devices require additional connection kit of PB4PNC400

400A Panel Board Add-on units

Page 8: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel BoardsOutgoing DevicesYA2 Frame Devices• 25kA and 36kA Rated breaking capacity• Exceeds the requirements of EN 60947-2• 3-pole devices have adjustable overload and instantaneous trips• Overload adjusts to 1 x In, 0.8 x In and 0.63 x In• 1-pole devices have fixed overload and instantaneous trips• Standard cable termination is 50mm² using cable clamps (available as an optional extra)• Maximum cable termination is 95mm² using M8 reduced palm width lugs• Terminal shrouds available as optional extras

6

Loadbank 125MCCB Panel Boards250A and 400A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

CurrentRating (A)

1-pole Product Code (25kA Fixed)

3-poleProduct Code(36kA Adjustable)

16 YA2N1P16T -20 YA2N1P20T YA2S3P20T32 YA2N1P32T YA2S3P32T40 YA2N1P40T -50 YA2N1P50T YA2S3P50T63 YA2N1P63T YA2S3P63T80 YA2N1P80T -100 YA2N1P100T YA2S3P100T125 YA2N1P125T YA2S3P125T

MCCB Panel BoardsSurge ProtectionClass I Surge Protection• Tested to withstand 10/350ms waveforms• 3 Phase & neutral• 25kA L-N• 100kA surge protector

Device Description ProductCode

Mounting

Type I Class I 3 Phase & Neutral 25kA L-N, 100kA surge protectorTested to withstand 10/350ms waveformsLightning impulse current (10/350ms) N-PE(Iimp) 100kA

DSPT3PN To be mounted in aservice centrePBYA2SC24

Class II Surge Protection• DIN-rail mounting for triple pole MCB• Comes complete with 40kA Three Phase Class 2 surge protection device• Knockout in the front shield for surge protection remote indication plate• Mounting Plate height is 435mm

Device Description ProductCode

Mounting

Type II Class II 3 Phase & Neutral 40kA with remote indicatorLow let through voltage of 600VMaximum surge current (8/20ms), Imax 40kAper phase

PBSM Comes completewith back plate forintegral mountingnext to the mainincoming device

NOTE: To provide isolation and protection it is recommended that Surge Protection devices arefed by either a 63A Type C MCB, 63A MCCB or 63A fused disconnector, dependant on the faultlevel.

Page 9: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

7

Loadbank 125MCCB Panel Boards

250A and 400A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel BoardsMeters, Current Transformers and Wiring LoomsMeter Housing Enclosure• Stackable meter housing unit for up to six outgoing DIN-rail mounted meters and corresponding current transformers• Can be mounted below or above the main panel board for incoming or outgoing metering options• Includes DIN-rail for mounting meters, current transformers and fuses• Meters, current transformers and wiring looms to be purchased separately• Matching width and depth to correspond with main panel board

DIN-rail Meter

Description Product Code1 Phase / 3 Phase DIN-rail Multi-function MeterRS485 Modbus and Pulse output communication as standardTotal harmonic distortion (THD) measurement up to the 31stharmonicTrue rms measurementProgrammable CT ratios from 1 to 9999Backlit LCD display

Ri3-01

Description Product CodeFused Voltage Tap Off Loom PBWPFuse to Voltage loom for Incoming meter PBWIFuse to Voltage loom for up to six outgoing meters PBWM6CT to Meter Loom PBWCT

Height (mm)

Width (mm)

Depth (mm)

Weight (kg)

Product Code

450 700 190 13 PBYA2MB

Use Description Maximum cableaperture (mm²)

Product Code

Incoming 250A 3-in-1 CT Core Size 45mm 150 M3N1-45-250/5Incoming 400A 3-in-1 CT Core Size 45mm 150 M3N1-45-400/5Outgoing 60A 3-in-1 CT Core Size 25mm 50 M3N1-25-60/5Outgoing 100A 3-in-1 CT Core Size 25mm 50 M3N1-25-100/5Outgoing 125A 3-in-1 CT Core Size 25mm 50 M3N1-25-125/5

3-in-1 Measuring Current Transformers• Up to Class 0.5 accuracy• System voltage up to 720V• Secondary output to Meter of 5A• Operating temperature of –20°C to +70°C

Wiring Looms• Quantity of 1 x PBWP fused voltage tap off loom required per board• Fuse to Voltage loom PBWI required for incoming meter • Fuse to Voltage loom PBWM6 required for up to six outgoing meters• CT to Meter Loom PBWCT required for each outgoing meter

Please see our Metering Selection Chart on the following page which detailsall of the parts required in order to correctly meter the Loadbank 125 PanelBoard Range

Page 10: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Meter Housing

For Incoming Meter:Qty 1 x PBYA2MB

For up to 6 outgoing Meters:Qty 1 x PBYA2MB

Step 1: Select Panel Board

Step 7: Select CT to Meter Loom

Panel Board x 1

PBWP x 1

PBWI x 1(for single incoming meter)

PBWM6 x 1 (for up to 6 meters)PBWM6 x 2 (above 6 meters)

Incoming CTs x 1

250A = M3N1-45-250/5400A = M3N1-45-400/5

Outgoing CTs x 1 per meter

60A = M3N1-25-60/5100A = M3N1-25-100/5125A = M3N1-25-125/5

PBWCT(1 required per meter)

YA2 Frame MCCB up to 125A

Metering Selection Chart

8

Loadbank 125MCCB Panel Boards250A and 400A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Step 4: Select Meter

Step 5: Incoming or Outgoing?

Step 5: Fuse to Voltage Loom

250APB206YAPB208YAPB212YA

400APB406YAPB408YAPB412YAPB416YA

DIN-rail Meter

Ri3-01

Incoming Metering Outgoing Metering

Step 2: Select Meter Housing

Step 3: Fused Voltage Tap off loom

Step 6: Select Current Transformers

Page 11: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

9

Loadbank 200800A Fuse Switch PanelBoards Outgoing Devices

up to 200A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Page 12: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Key Features

Panel boards are available in either a 6 or 10TP&N outgoing ways with Form 2b Type 2 asstandard. Form 4a Type 2 can be achievedwith shielding available as an optionalaccessory.

Several incoming options are available from200A to 800A and a comprehensive range ofmetering facilities is available for compliancewith the Building Regulations Part L2.

A variety of add-on enclosures is available tocomplement this range, including MCBdistribution boards, general purposeenclosures and cableways to allow formetering and surge protection devices.

The standard finish is epoxy powder coatingin light grey RAL 7035.

10

Incoming OptionsOur Loadbank 200 fuse switch panel board system canhouse either a 400A, 630A or 800A fuse switch byselecting the required add-on incoming enclosure.Add-on incoming enclosures are supplied with allnecessary copper connections and fully shroudedincoming terminations. For 200A incoming option youcan install a 200A fuse switch in a spare outgoing waywith no need for an additional add-on enclosure.

PAGE 12

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

The Loadbank 200 range is a modularpanel board system designed to fulfil theneed for fuse switch panel boards thatneed up to 800A incoming devices and upto 200A outgoing devices.

Loadbank 200800A Fuse Switch PanelBoards Outgoing devices up to 200A

BusbarThe Loadbank 200 fuse switch panelboard has an ASTA certified shortcircuit rating of 50kA for 1 second.

PAGE 12

ComplianceSwitch Fuse Panel Boards EN 61439-2Fuse switches EN 60947-3

Outgoing WaysThese boards are availablewith either 6 or 10 outgoingfuse switch ways to houseskeleton fuse switches upto 200A.

PAGE 13

Page 13: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

11

FormThe Loadbank 200 fuse switch panelboard is Form 2 as standard. This caneasily be increased to Form 4 withoptional shielding fitted.

Ingress ProtectionAs standard these fuse switch panelboards have an ingress protection ofIP4X as standard.

Add-on EnclosuresThe Loadbank 200 range is flexible andmodular with standard width and depthsfor add-on enclosures. Our extensive add-on enclosure options for this rangeinclude; SP&N MCB distribution boards,TP&N MCB distribution boards, generalpurpose enclosures, side cableways,service centres, surge protection andincoming and outgoing metering.

PAGE 14

PAGE 12

PAGE 12

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Surge ProtectionBoth Type I Class I and Type II Class IIsurge protection options are available forthis range in either a specially designed 2module high side cableway or as amounting frame to be installed within aside cableway depending on application.

PAGE 16

MeteringBy using side cableways and meteringdoor kits this range can easily have DIN96panel mounted metering added forincoming and outgoing ways. A range ofpre-cut wiring looms are available and thecurrent transformers can be installedwithin the cableways for neatness ofinstallation.

PAGES 15-18

Page 14: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Fuse Switch Panel Boards800A Form 4a Type 2 (with shielding) 50kA for 1 secondMain features• Certified at 50kA for 1 second• Form 2b, Type 2 as standard• Form 4a Type 2 achieved with optional shielding fitted• IP4X as standard• Integral incoming option available using 200A fuse switch in an available outgoing way• Width is 750mm and depth is 200mm. Height as per table below.

12

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Outgoing Triple Pole Ways

ModularHeight

Height(mm)

Weight (kg)

Panel Board Product Code

6 5 760 59 LF806A10 8 1216 98 LF810A

Fuse Switch Panel Board Accessories

Add-on Incoming Device Enclosures• Supplied with all necessary copper connections to connect incoming device to the busbar system• Incoming terminations are fully shrouded• Supplied with two side plates and the end plate from the panel board can be used as the bottom plate• IP4X Ingress Protection• Incoming device to be ordered separately

Current Rating(A)

ModularHeight

Height(mm)

Weight(kg)

IncomingDevice Type

ProductCode

400 5 762 48.50 L frame fuseswitch

LF1F4A

630 / 800 6 914 66.50 N frame fuseswitch

LF1F8A

Incoming Device Options• Exceeds the requirements of EN 60947-3• 80kA rms fused short-circuit capacity• AC23A Utilisation category• Full uninterrupted duty• 415V AC rated voltage

CurrentRating(A)

No ofPoles

Max. cabletermination(mm²)

Product Code Enclosurerequired

CableTerminals (if required)

400 TP&N 300 SL3P400N LF1F4A N/A400 4 Pole 300 SL4P400 LF1F4A N/A630 TP&N 630 SN3P630N LF1F8A SNCET630 4 Pole 630 SN4P630 LF1F8A SNCET800 TP&N 630 SN3P800N LF1F8A SNCET800 4 Pole 630 SN4P800 LF1F8A SNCET

Description Product CodeForm 4 shielding for cable up to 70mm² (1 required per device) LFS41AForm 4 shielding for cable up to 150mm² (1 required per device) LFS42APanel Board vertical stacking kit LCFVKBlank cover for fuse switch handle LFXHBASpare End Plate LGES

Page 15: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

13

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA

for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Fuse Switch Panel BoardsOutgoing Devices63A to 200A Skeleton Switches• Exceeds the requirements of EN 60947-3• 80kA rms fused short circuit capacity• AC23A Utilisation Category• Full uninterrupted duty• 415V AC rated voltage

*All outgoing Skeleton fuse switches are supplied without fuses. Solid links for isolation areavailable as an optional accessory.

Current Rating (A) 3-pole Product Code

4-pole Product Code

63 SF3P63N SF4P63100 SF3P100N SF4P100125 SF3P125N SF4P125160 SF3P160N SF4P160200 SF3P200N SF4P200

Description Current Rating (A) Product Code

Solid LinksSold Link (1 required per phase) 63 HFL63Solid Link (1 required per phase) 100 to 200 HFL200ASolid Link (1 required per phase) 315 and 400 HLL400Solid Link (1 required per phase) 630 and 800 HNL800Terminal Shrouds and BarriersTerminal Shroud and barriers 63 to 200 SFTSSTerminal Shroud and barriers 400 SLTSTerminal Shroud and barriers 630 and 800 SNTSTerminal Barrier (Set of 3) 63 to 200 SFTBTerminal Barrier (Set of 3) 400 SLTBTerminal Barrier (Set of 3) 630 and 800 Supplied as standardExtension TerminalsCable extension terminals (Set of 8) 630 and 800 SNCET

Accessories for Incoming and Outgoing Skeleton Switches

Page 16: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Fuse Switch Panel BoardsAdd-on enclosuresGeneral Purpose Enclosures• IP4X Ingress Protection• Enclosures are 750mm wide and 200mm deep. Height as per table below.• Supplied with two side and two end plates as standard• Replacement top / bottom plate is product code LGES• Replacement side plate is product code MXPE*F where the * represents the modular height• Can be mounted above or below main panel board as required

14

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

ModularHeight

Height (mm)

Weight(kg)

Product Code

1 152 4 LEBM12 305 10 LEBM23 457 16 LEBM34 609 22 LEBM45 762 28 LEBM56 914 34 LEBM6

Side Cableway Extension Enclosures• IP4X Ingress Protection• Recommended for cables over 70mm²• Enclosures are 250mm wide and 200mm deep. Height as per table below.• No side plates supplied as designed to use the side plate from the panel board• Can be used with Cableway Metering Door Kits for panel mounted metering options

Cableway Metering Door Kits• For incoming and outgoing panel mounted metering• Metering door kit designed to be used with standard cableway• Includes DIN-rail for mounting fuses and Current Transformers within cableway• Meters, Current Transformers and wiring looms not supplied

MCB Distribution Boards and Service Centres• IP3X as standard and IP4X with doors fitted• MCB Distribution boards have fully shielded busbars and interconnections• Space saving twin option TP&N Distribution board option

ModularHeight

Height(mm)

Weight(kg)

CablewayProduct Code

Cableway MeteringDoor Kit (if required)

1 152 2 LECM1 N/A2 305 4 LECM2 LECMD23 457 6 LECM3 LECMD34 609 8 LECM4 LECMD45 762 10 LECM5 LECMD56 914 12 LECM6 LECMD68 1219 14 LECM8 LECMD8

Description ModularHeight

Height(mm)

Weight(kg)

ProductCode

Door Kit ProductCode

17 Way SP&N Distribution Board 1 152 15 LDS17 LD1DS6 Way TP&N Distribution Board 2 305 23 LDT106X LD1D06X12 Way TP&N Distribution Board 3 457 30 LDT112X LD1D12X2 x 12 Way TP&N Distribution Board 4 609 35 LDT212X* LD2D12X24 Way Modular Service Centre 1 152 10 LDS24 LD1DS

* Only double module RCBOs can be fitted in this enclosure

Page 17: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

15

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA

for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Fuse Switch Panel BoardsMeters and Current TransformersPanel Mounted Meters - Incoming and Outgoing• Fully programmable CT ratios• Modbus and Pulse Plug-in communication modules available for Ci1 meter as an optional extra• Integra 1630 meters with built in communication modules

Meter Type Outputs Product Code ModbusModule

PulseModule

Digital kWh Meter None Ci1-01 MOD-01 PUL-01Digital Multi-functionMeter

Pulse & Modbus INT-1630-M-5-M-110 Standard Standard

Single Current Transformers - Incoming • Up to Class 0.5 accuracy• System voltage up to 720V• Secondary output to Meter of 5A• Operating temperature of –20°C to +70°C• Three single CTs required per incoming meter• For use with Ci1 and Integra 1630 meters

Case Size Current Rating(A)

Maximum Cablesize (mm²)

Product Code

400A Single CT 400 32 M63N-400/5600A Single CT 600 32 M63N-600/5800A Single CT 800 42 M93L-800/5

3-in-1 Current Transformers - Outgoing• Up to Class 0.5 accuracy• System voltage up to 720V• Secondary output to Meter of 5A• Operating temperature of –20°C to +70°C• One required per outgoing meter

Note:M93L-800/5 is for use with LF1F8A enclosure and 800A fuse switch only.

Case Size CurrentRating(A)

MaximumCable size(mm²)

Product Code for use with Ci1 andIntegra 1630 Meter

3-in-1 CT Core Size 35mm 100 95 M3N1-35-100/53-in-1 CT Core Size 35mm 125 95 M3N1-35-125/53-in-1 CT Core Size 35mm 160 95 M3N1-35-160/53-in-1 CT Core Size 35mm 200 95 M3N1-35-200/53-in-1 CT Core Size 35mm 250 95 M3N1-35-250/5

Page 18: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Fuse Switch Panel BoardsSurge ProtectionSurge Suppression Device MountingThere are two different ways of providing surge protection for the Loadbank 200 Panel Boardrange and both options are offered with Type I and Type II surge protection devices.

Option 1: 2 module high cableway complete with surge protection device

Option 2: Frame for mounting the surge protection device in a cableway larger than 2 moduleshigh

Type I Class I Surge Suppression Device• Three-phase & neutral, 25kA L-N, 100kA surge protector• Maximum continuous operating voltage (Uc) is 275V AC rms• Lightning impulse current 10/350ms, L-N (Iimp) is 25kA• Lightning impulse current 10/350ms, N-PE (Iimp) is 100kA• Total lightning impulse current 10/350ms, L1, L2, L3, N-PE (Itotal) is 100kA

16

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

DeviceSeries

MountingOption

Method of Mounting Product Code

DSPT Option 1 2 Module cableway complete withDSPT3PN Surge Suppression Device

LECM2SP

DSPT Option 2 Frame for mounting inside a cablewaycomplete with DSPT3PN SurgeSuppression Device

LECM2SM

Type II Class II Surge Suppression Device• Two stage (redundant) protection with pre-failure indication• Maximum continuous operating voltage (Uc) L-N is 300V rms and L-L is 500V rms• Maximum surge current (8/20ms) (Imax) is 30kA per phase• Leakage current to earth is 600mA

DeviceSeries

MountingOption

Method of Mounting Product Code

DSPE Option 1 2 Module cableway complete withDSPE600R Surge Suppression Device

LECK2SP

DSPE Option 2 Frame for mounting inside a cablewaycomplete with DSPE600R SurgeSuppression Device

LECK2SM

NOTE: To provide isolation and protection it is recommended that Surge Protection devices arefed by either a 63A Type C MCB, 63A MCCB or 63A fused disconnector, dependant on the faultlevel.

Page 19: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

17

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA

for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Fuse Switch Panel BoardsWiring LoomsProduct Code for use with Ci1 and Integra 1630 meters

Metering Harnesses• 1 x LBWP Fused voltage tap off loom required per cableway for outgoing meters• 1 x LBWI Fused voltage tap off loom required for incoming meter• Fuse to Voltage loom LBWM6 required for up to six outgoing meters and 2 x LBWM6 looms required for 6 to 12 outgoing meters• CT to Meter Loom LBWCT required for each outgoing meter

Description Product CodeFused Voltage Tap Off Loom LBWPFuse to Voltage loom for Incoming meter LBWIFuse to Voltage loom for up to 6 outgoing meters LBWM6CT to Meter Loom LBWCT

Please see our Metering Selection Chart on the following page which detailsall of the parts required in order to correctly meter the Loadbank 200 PanelBoard Range.

Page 20: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Panel Board x 1

LF806ALF810A

Step 1: Select Panel Board

Step 7: Select CT

Step 8: Select outgoing devices

Ci1-01INT-1630-M-5-M-110

Up to 6 meters= LBWM6 x 1

6 to 12 meters= LBWM6 x 2

Skeleton fuse switches up to 200A

Metering Selection ChartCi1 and Integra 1630 Meters

18

Loadbank 200Fuse Switch Panel Boards800A Form 2 & 4 50kA for 1 second

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Step 4: Select voltage tap off loom

Step 5: Select Meter

Step 6: Select CT to Meter Loom

Left Hand Cableway Outgoing

LBWP x 1

Step 2: Select incoming enclosure and incoming device

Step 3: Select matching cableways and cableway metering door kits

as required

400A LF1F4A x 1

SL3P400N or SF4P400

630/800A LF1F8A x 1

SN3P630N, SF4P630,SN3P800N or SF4P800

Metering door kit

Cableways can be fitted to oneor both sides of the board andincoming enclosure as per your

cabling requirements.

If metering is required thenplease order a metering doorkit to suit the cableway.

Standard installation wouldrequire a metering door kit tobe fitted to just one side ofthe incoming enclosure for

the incoming meter.

SideCableway

Board

LECMD5LECM5LF806A

LECMD8LECM8LF810A

Metering door kit

SideCableway

Incoming Enclosure

LECMD5LECM5LF1F4A

LECMD6LECM6LF1F8A

Incoming Meter

LBWI x 1

Right Hand Cableway Outgoing

LBWP x 1

Up to 6 meters= LBWM6 x 1

6 to 12 meters= LBWM6 x 2

Ci1-01INT-1630-M-5-M-110

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter1 x LBWCT per meter

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 3 required per Meter:M63N-400/5M63N-600/5M93L-800/5

Board

Incomingenclosure

Cableways andmetering doorkits can befitted to lefthand side ofrequired forextra cablingroom andmetering

Sidecablewaywith

meteringdoor kitfitted foroutgoingmeters

Cablewayand doorkit forincomingmeter

Page 21: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

19

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Loadbank 250400A and 800A MCCBPanel Boards, Outgoing

devices up to 250A

Page 22: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

Key Features

20

Outgoing WaysBoth the 400A and 800Apanel board versions areavailable with 6, 12 or 18triple-pole outgoing ways.

Incoming OptionsThere is a variety of incoming options for this rangeincluding; MCCBs and switch disconnectors up to800A, fuse switches up to 800A and directconnection. Each incoming device has a matching add-on incoming enclosure which includes allnecessary copper connections for installation.

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

The Loadbank 250 modular enclosuresystem is engineered to provide theunrivalled flexibility and build simplicityneeded in order to produce a wide rangeof power distribution solutions. Itconsists of TP&N busbars of 400A and800A with three different sizes of 6, 12or 18 outgoing ways.

Loadbank 250400A and 800A MCCBPanel Boards, Outgoingdevices up to 250A

BusbarThe Loadbank 250 panel boards havean ASTA certified busbars with a short-circuit withstand rating of 36kA for 1second for the 400A boards and 50kAfor 1 second for the 800A boards.

PAGES 22-24

This range houses the incoming and outgoingdevices in separate adjoining enclosureswhich then allows the widest range ofpossible circuit permutations, includingoversized outgoing circuits, which can thenbe accommodated within a common format.

Incoming options range from 250A MCCBs to800A switch fuses depending on the board.There is a single frame size MCCB foroutgoing devices which is the YB3 frameMCCB up to 250A.

The standard finish is epoxy powder coatingin light grey RAL 7035.

CompliancePanel Boards EN 61439-2MCCBs EN 60947-2

PAGES 22-24

PAGES 22-24

Page 23: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

21

FormThe Loadbank 250 panel boards areavailable as Form 3a as standard,however we also produce a specialisedForm 4a Type 2 panel board with 6 or 10outgoing triple-pole ways.

Ingress ProtectionAs standard the MCCB panel boards inthis range have an ingress protection ofIP3X and IP4X with the optional extradoor kit fitted.

Add-on EnclosuresThe Loadbank 250 range is flexible andmodular with standard width and depthsfor add-on enclosures. Our extensive add-on enclosure options for this rangeinclude; SP&N MCB distribution boards,TP&N MCB distribution boards, generalpurpose enclosures, side cableways,service centres, surge protection andincoming and outgoing metering.

PAGE 27

PAGES 22-24

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Surge ProtectionBoth Type I Class I and Type II Class IIsurge protection options are available forthis range in either a specially designed 2module high side cableway or as amounting frame to be installed within aside cableway depending on application.

PAGE 29

MeteringBy using side cableways and meteringdoor kits this range can easily have DIN96panel mounted metering added forincoming and outgoing ways. A range ofpre-cut wiring looms are available and thecurrent transformers can be installedwithin the cableways for neatness ofinstallation.

PAGES 28-33

Outgoing DevicesThe outgoing ways are supported by a single deviceframe size up to 250A which is our Loadline YB3MCCBs. These are available in single-pole andtriple-pole versions and also as four-pole versions forthe Loadbank Form 4 panel board. A range ofaccessories are available for the Loadline MCCBs tomeet your specific requirements.

PAGES 25-26

PAGES 22-24

Page 24: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel Boards250A/400A Form 3a 36kA for 1 secondMain Features• ASTA certified busbars rated at 36kA for 1 second• Form 3a as standard• Width is 750mm and depth is 200mm. Height as per the table below.• Supplied with top plate and two side plates as standard• Ingress protection of IP3X. IP4X with door kit fitted (available as optional extra)

22

Loadbank 250400A MCCBPanel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Outgoing TriplePole Ways

ModularHeight

Height(mm)

Weight(kg)

Panel BoardProduct Code

Door KitProduct Code

6 4 609 36 LB406YA3 LBDD0612 6 914 52 LB412YA3 LBDD1218 8 1219 66 LB418YA3 LBDD18

Panel Board Accessories

Add-on Incoming Device Enclosures• Supplied with all necessary copper connections to connect incoming device to the busbar system• Supplied with two side plates and one end plate as standard• Incoming device to be ordered separately • YA3NL Neutral link to be ordered as an optional accessory if required with the LB1YA3 enclosure

CurrentRating(A)

ModularHeight

Height(mm)

Weight(kg)

Incoming Device Type ProductCode

250 3 457 26 YB3 frame MCCB LB1YA3400 5 762 45 YA6 frame MCCB LB1Y6400 2 305 18 Direct connection LBDR4200 3 457 37.5 F frame fuse switch LB1F2A400 5 762 48.5 L frame fuse switch LB1F4A

Incoming Device Options

CurrentRating (A)

No ofPoles

Device Type Product Code Enclosurerequired

160 3 25kA MCCB YB3N3P160T LB1YA3200 3 25kA MCCB YB3N3P200T LB1YA3250 3 25kA MCCB YB3N3P250T LB1YA3160 3 36kA MCCB YB3S3P160T LB1YA3200 3 36kA MCCB YB3S3P200T LB1YA3250 3 36kA MCCB YB3S3P250T LB1YA3250 3 Switch disconnector YB3B3P250D LB1YA3160 4 25kA MCCB YB3N4P160T LB1YA3200 4 25kA MCCB YB3N4P200T LB1YA3250 4 25kA MCCB YB3N4P250T LB1YA3160 4 36kA MCCB YB3S4P160T LB1YA3200 4 36kA MCCB YB3S4P200T LB1YA3250 4 36kA MCCB YB3S4P250T LB1YA3250 4 Switch disconnector YB3B4P250D LB1YA3400 3 50kA MCCB YA6H3P400T LB1Y6400 4 50kA MCCB YA6H4P400T LB1Y6400 3 Switch disconnector YA6B3P400D LB1Y6400 4 Switch disconnector YA6B4P400D LB1Y6200 3 F frame fuse switch SF3P200N LB1F2A200 4 F frame fuse switch SF4P200 LB1F2A400 3 L frame fuse switch SL3P400N LB1F4A400 4 L frame fuse switch SL4P400 LB1F4A

Description Product Code3 pole blanking plate LBBP3PYA3Spare End Plate LGESCylinder Door Lock DBXCLPadlocking Door Kit DBXPLPanel board stacking kit LBCK4Busbar extension terminals LBSKE

Fitted with incoming housing and metering

Page 25: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

23

Loadbank 250800A MCCB

Panel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel Boards800A Form 3a 50kA for 1 secondPanel Boards• ASTA certified busbars rated at 50kA for 1 second• Form 3a as standard• Width is 750mm and depth is 200mm. Height as per the table below.• Supplied with top plate and two side plates as standard• Ingress protection of IP3X. IP4X with door kit fitted (available as optional extra)

Outgoing TriplePole Ways

ModularHeight

Height(mm)

Weight(kg)

Panel BoardProduct Code

Door KitProduct Code

6 4 609 42 LB806YA3 LBDD0612 6 914 62 LB812YA3 LBDD1218 8 1219 78 LB818YA3 LBDD18

Panel Board Accessories

Add-on Incoming Device Enclosures• Supplied with all necessary copper connections • Neutral links supplied as standard• Incoming device to be ordered separately

CurrentRating (A)

ModularHeight

Height(mm)

Weight(kg)

Incoming Device Type ProductCode

400/630 5 762 45 YA6 frame MCCB LB1Y6800 3 457 23 Direct Connection LBDR8800 6 912 69 YA7 frame MCCB LB1Y7

Incoming Device Options

CurrentRating (A)

No of Poles

Device Type Product Code Enclosurerequired

400 3 Switch disconnector YA6B3P400D LB1Y6630 3 50kA MCCB YA6H3P630T LB1Y6630* 3 Switch disconnector YA6B3P800D LB1Y6400 4 Switch disconnector YA6B4P400D LB1Y6630 4 50kA MCCB YA6H4P630T LB1Y6630* 4 Switch disconnector YA6B4P800D LB1Y6800 3 50kA Electronic MCCB YA7H3P800E LB1Y7800 3 Switch disconnector YA7B3P800D LB1Y7800 4 50kA Electronic MCCB YA7H4P800E LB1Y7800 4 Switch disconnector YA7B4P800D LB1Y7

Description Product Code3 pole blanking plate LBBP3PYA3Spare End Plate LGESCylinder Door Lock DBXCLPadlocking Door Kit DBXPLPanel board stacking kit LBCK8Busbar extension terminals LBSKE

* Switch Disconnector rating when installed in LB1Y6

Twin YA5 Outgoing Housing (not designed for use with Form 4 panel boards)• Can be mounted direct to incoming enclosure without connection kit• When mounting to 800A panelboard connection kits are required (LBSKE and LBCK8)• Cableway extension enclosures are necessary to assist with cabling• Devices to be ordered seperately• Optional outgoing terminal shroud YA5TS3P for spread extensions YA5XT3P if required (1 per MCCB)• YA5 MCCB busbar terminal cover not required, however if internal degree of protection required is greater than IP2X then terminal cover YA5TC3P required (1 per MCCB)

Description ModularHeight

Height(mm)

Weight(kg)

ProductCode

Door KitProduct Code

Twin YA5 (400A max each) 3 456 35 LB802YA5 LBDD02

Castell Kit (Excl. locks) LB802CLKCastell Lock Type K Series Form 1, 6-4mm bolt protrusion

Page 26: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel Boards800A Form 4 50kA for 1 secondPanel Boards• ASTA certified busbars rated at 50kA for 1 second• Form 3a Type 2 as standard and Form 4a Type 2 with optional shielding fitted• Outgoing device is 3 pole YB3 frame MCCB with neutral link (available separately under product code YA3NL) or 4 pole YB3 frame MCCB• Exceeds the requirements of EN 61439-2• IP4X Ingress protection with doors fitted• Fully rated neutrals• Panel board does not accept 1-pole outgoing devices• Panel board width is 750mm and depth is 200mm. Height is as per table below.

24

Loadbank 250800A MCCBPanel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Outgoing TriplePole Ways

ModularHeight

Height(mm)

Weight(kg)

Panel BoardProduct Code

Door KitProduct Code

6 5 760 59 LF806YA MXD0610 8 1216 98 LF810YA MXD10

Panel Board Accessories

Add-on Incoming Device Enclosures• Form 4 as standard• Incoming device to be ordered separately

CurrentRating(A)

ModularHeight

Height(mm)

Weight(kg)

Incoming DeviceType

ProductCode

ConnectionKit

400 5 762 35 L frame fuse switch LF1F4A Not required630/800 6 914 47 N frame fuse switch LF1F8A Not required400 to800

5 762 45.2 YA6 frame MCCB /Switch disconnector

MMS15Y* MCFMY6

Incoming Fuse Switch Device Options

Description Product CodeForm 4 shielding for cables up to 70mm² LFS41YAForm 4 shielding for outgoing cables up to 150mm² LFS42YAVertical stacking kit LCFVKBlanking plate for unused outgoing way YA3F4BP

CurrentRating (A)

No ofPoles

Framesize

Max. cabletermination (mm²)

ProductCode

Enclosurerequired

400 TP&N L 240 SL3P400N LF1F4A400 4 L 240 SL4P400 LF1F4A630 TP&N N 630 SN3P630N LF1F8A630 4 N 630 SN4P630 LF1F8A800 TP&N N 630 SN3P800N LF1F8A800 4 N 630 SN4P800 LF1F8A

Incoming MCCB Device Options• 3 Pole and 4 pole MCCBs have adjustable thermal and instantaneous trip

CurrentRating (A)

NoofPoles

Device Type Max. cabletermination (mm²)

ProductCode

Enclosurerequired

400 3 Switch disconnector 240 YA6B3P400D MMS15Y*400 3 50kA MCCB 240 YA6H3P400T MMS15Y*630 3 50kA MCCB 240 YA6H3P630T MMS15Y*800 3 Switch disconnector 240 YA6B3P800D MMS15Y*800 3 50kA MCCB 240 YA6H3P800T MMS15Y*400 4 Switch disconnector 240 YA6B4P400D MMS15Y*400 4 50kA MCCB 240 YA6H4P400T MMS15Y*630 4 50kA MCCB 240 YA6H4P630T MMS15Y*800 4 Switch disconnector 240 YA6B4P800D MMS15Y*800 4 50kA MCCB 240 YA6H4P800T MMS15Y*

* When ordering the MMS15Y please alsoorder 2 x MXPE5F side plates per enclosure.The MMS15Y is supplied with a neutral link asstandard.

Page 27: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

25

Loadbank 250400A and 800A MCCBPanel Boards, Outgoing

devices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel BoardsOutgoing DevicesMain Features• Exceeds the requirements of EN 60947-2• 1-pole MCCBs have fixed thermal and instantaneous trips• 3-pole and 4-pole MCCBs have both adjustable thermal and instantaneous trips• Rated insulation voltage is 800V AC• Standard cable termination is 95mm²• Maximum cable termination is 150mm² using M8 reduced palm width lugs• YA3NL Neutral Link for use on Form 4a Type 2 only

CurrentRating (A)

YA3 MCCB YA3/YB3 MCCB

Max(A)

Min(A)

1-pole(fixed)

3-pole (adjustable) 4-pole (adjustable)

Switch Disconnectors250 - - YB3B3P250D YB3B4P250DThermal / Magnetic 25kA16 16 YA3N1P16T - -20 13 YA3N1P20T - -32 20 YA3N1P32T - -40 25 YA3N1P40T - -50 32 YA3N1P50T YB3N3P50T* YB3N4P50T*63 40 YA3N1P63T YB3N3P63T* YB3N4P63T*80 50 YA3N1P80T - -100 63 YA3N1P100T YB3N3P100T YB3N4P100T125 80 YA3N1P125T YB3N3P125T YB3N4P125T160 100 YA3N1P160T YB3N3P160T YB3N4P160T200 125 - YB3N3P200T YB3N4P200T250 160 - YB3N3P250T YB3N4P250TThermal / Magnetic 36kA50 32 - YB3S3P50T* YB3S4P50T*63 40 - YB3S3P63T* YB3S4P63T*100 63 - YB3S3P100T YB3S4P100T125 80 - YB3S3P125T YB3S4P125T160 100 - YB3S3P160T YB3S4P160T200 125 - YB3S3P200T YB3S4P200T250 160 - YB3S3P250T YB3S4P250TThermal / Magnetic 65kA50 32 - YA3J3P50T YA3J4P50T63 40 - YA3J3P63T YA3J4P63T100 63 - YA3J3P100T YA3J4P100T125 80 - YA3J3P125T YA3J4P125T160 100 - YA3J3P160T YA3J4P160T200 125 - YA3J3P200T YA3J4P200T250 160 - YA3J3P250T YA3J4P250T

Current Rating (A) 25kA 3 Pole Product Code 50kA 3 Pole Product Code160 to 250A YA5N3P250T YA5H3P250T250A to 400A YA5N3P400T YA5H3P400T

YA5 MCCBs for LB802YA5 enclosure• MCCBs have both adjustable thermal and instantaneous trips• Standard cable termination is 95mm² or 185mm² using reduced palm width lugs• For use with LB802YA5 enclosure

* 50A and 63A MCCBs have fixed instantaneous trip

Page 28: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel BoardsAccessories for outgoing devicesAccessories for YB3 MCCB outgoing devices

26

Loadbank 250400A and 800A MCCBPanel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Description YB33-pole ProductCode

YB34-pole ProductCode

Cable ClampsCable Clamps YB3CC3P YB3CC4PTerminal ProtectionTerminal Shroud for cable lugs YB3TS3P YB3TS4PInterphase Barrier (Set of 1) YB3TBTerminal Shroud Cover Lock YBTSCLDolly lock YBDL1Shunt TripsShunt Trip 100-120V AC YBST120ACShunt Trip 200-240V AC YBST240ACShunt Trip 380-450V AC YBST450ACShunt Trip 24V DC YBST24DCShunt Trip 48V DC YBST48DCShunt Trip 100-120V DC YBST120DCShunt Trip 200-240V DC YBST240DCUnder-voltage ReleaseUnder-voltage release 100-120V AC YBUVR120ACUnder-voltage release 200-240V AC YBUVR240ACUnder-voltage release 380-450V AC YBUVR450ACUnder-voltage release 24V DC YBUVR24DCUnder-voltage release 100-120V DC YBUVR120DCUnder-voltage release 200-240V DC YBUVR240DC

Accessories for YA5 MCCBs outgoing devices

Description 3-pole Product CodeCable ClampsCable Clamps YA5CC3P

Terminal ProtectionTerminal Shroud for spread type extension terminals and cable lugs YA5TS3PSpread type extension terminals YA5XT3PInterphase Barrier (Set of 1) YA5TB Dolly lock YA5DL

Shunt TripsShunt Trip 100-120V AC YAST115AC

Shunt Trip 200-240V AC YAST240AC Shunt Trip 380-450V AC YAST450AC Shunt Trip 24V DC YAST24DC

Under-voltage ReleaseUnder-voltage release 100-120V AC YAUVR120AC Under-voltage release 200-240V AC YAUVR240ACUnder-voltage release 380-450V AC YAUVR450AC Under-voltage release 24V DC YAUVR24DC

Page 29: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

27

Loadbank 250400A and 800A MCCBPanel Boards, Outgoing

devices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel BoardsAdd on enclosuresGeneral Purpose Enclosures• IP4X Ingress Protection• Enclosures are 750mm wide and 200mm deep. Height as per table below.• Supplied with two side and two end plates as standard• Replacement top / bottom plate is product code LGES• Replacement side plate is product code MXPE*F where the * represents the modular height• Can be mounted above or below main panel board as required

* Only double module RCBOs can be fitted in this enclosure

Side Cableway Extension Enclosures• IP4X Ingress Protection• Recommended for cables over 70mm²• Enclosures are 250mm wide and 200mm deep. Height as per table below.• No side plates supplied as designed to use the side plate from the panel board• Can be used with Cableway Metering Door Kits for panel mounted metering options

Cableway Metering Door Kits• For incoming and outgoing panel mounted metering• Metering door kit designed to be used with standard cableway• Includes DIN-rail for mounting fuses and Current Transformers within cableway• Meters, Current Transformers and wiring looms not supplied

MCB Distribution Boards and Service Centres• IP3X as standard and IP4X with doors fitted• MCB Distribution boards have fully shielded busbars and interconnections• Space saving twin TP&N Distribution board option

ModularHeight

Height(mm)

Weight(kg)

CablewayProduct Code

Cableway MeteringDoor Kit (if required)

1 152 2 LECM1 N/A2 305 4 LECM2 LECMD23 457 6 LECM3 LECMD34 609 8 LECM4 LECMD45 762 10 LECM5 LECMD56 914 12 LECM6 LECMD68 1219 14 LECM8 LECMD8

ModularHeight

Height (mm)

Weight(kg)

Product Code

1 152 4 LEBM12 305 10 LEBM23 457 16 LEBM34 609 22 LEBM45 762 28 LEBM56 914 34 LEBM6

Description ModularHeight

Height(mm)

Weight(kg)

ProductCode

Door Kit ProductCode

17 Way SP&N Distribution Board 1 152 15 LDS17 LD1DS6 Way TP&N Distribution Board 2 305 23 LDT106X LD1D06X12 Way TP&N Distribution Board 3 457 30 LDT112X LD1D12X2 x 12 Way TP&N Distribution Board 4 609 35 LDT212X* LD2D12X24 Way Modular Service Centre 1 152 10 LDS24 LD1DS

Page 30: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel BoardsMeters and Current TransformersPanel Mounted Meters - Incoming and Outgoing• Fully programmable CT ratios• Modbus and Pulse Plug-in communication modules available for Ci1 meter as an optional extra• Integra 1630 meters with built in communication modules

28

Loadbank 250400A and 800A MCCBPanel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Case Size Current Rating(A)

Maximum Cablesize (mm²)

Product Code

400A Single CT 400 32 M63N-400/5600A Single CT 600 32 M63N-600/5800A Single CT 800 32 M63N-800/5800A Single CT 800 42 M93L-800/5 *

Single Current Transformers - Incoming • Up to Class 0.5 accuracy• System voltage up to 720V• Secondary output to Meter of 5A• Operating temperature of –20°C to +70°C• Three single CTs required per incoming meter• For use with Ci1 and Integra 1630 panel mounted meters

3-in-1 Current Transformers - Outgoing• Up to Class 0.5 accuracy• System voltage up to 720V• Secondary output to Meter of 5A• Operating temperature of –20°C to +70°C• One required per outgoing meter

Meter Type Outputs Product Code ModbusModule

PulseModule

Digital kWh Meter None Ci1-01 MOD-01 PUL-01Digital Multi-functionMeter

Pulse & Modbus INT-1630-M-5-M-110 Standard Standard

Case Size CurrentRating(A)

MaximumCable size(mm²)

Product Code for use with Ci1 andIntegra 1630 Meter

3-in-1 CT Core Size 35mm 100 95 M3N1-35-100/53-in-1 CT Core Size 35mm 125 95 M3N1-35-125/53-in-1 CT Core Size 35mm 160 95 M3N1-35-160/53-in-1 CT Core Size 35mm 200 95 M3N1-35-200/53-in-1 CT Core Size 35mm 250 95 M3N1-35-250/5

*Note:M93L-800/5 is for use with LF1F8A enclosure and 800A fuse switch only.

Page 31: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

29

Loadbank 250400A and 800A MCCBPanel Boards, Outgoing

devices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

MCCB Panel BoardsSurge ProtectionSurge Suppression Device MountingThere are two different ways of providing surge protection for the Loadbank 250 Panel Boardrange and both options are offered with Type I and Type II surge protection devices.

Option 1: 2 module high cableway complete with surge protection device

Option 2: Frame for mounting the surge protection device in a cableway larger than 2 moduleshigh

Type I Class I Surge Suppression Device• Three-phase & neutral, 25kA L-N, 100kA surge protector• Maximum continuous operating voltage (Uc) is 275V AC rms• Lightning impulse current 10/350ms, L-N (Iimp) is 25kA• Lightning impulse current 10/350ms, N-PE (Iimp) is 100kA• Total lightning impulse current 10/350ms, L1, L2, L3, N-PE (Itotal) is 100kA

Type II Class II Surge Suppression Device• Two stage (redundant) protection with pre-failure indication• Maximum continuous operating voltage (Uc) L-N is 300V rms and L-L is 500V rms• Maximum surge current (8/20ms) (Imax) is 30kA per phase• Leakage current to earth is 600mA

DeviceSeries

MountingOption

Method of Mounting Product Code

DSPT Option 1 2 Module cableway complete withDSPT3PN Surge Suppression Device

LECM2SP

DSPT Option 2 Frame for mounting inside a cablewaycomplete with DSPT3PN SurgeSuppression Device

LECM2SM

DeviceSeries

MountingOption

Method of Mounting Product Code

DSPE Option 1 2 Module cableway complete withDSPE600R Surge Suppression Device

LECK2SP

DSPE Option 2 Frame for mounting inside a cablewaycomplete with DSPE600R SurgeSuppression Device

LECK2SM

NOTE: To provide isolation and protection it is recommended that Surge Protection devices arefed by either a 63A Type C MCB, 63A MCCB or 63A fused disconnector, dependant on the faultlevel.

Page 32: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

MCCB Panel BoardsWiring LoomsWiring Looms for use with Ci1 and Integra 1630 Meters - Incoming andOutgoing

Metering Harnesses• 1 x LBWP Fused voltage tap off loom required per cableway for outgoing meters• 1 x LBWI Fused voltage tap off loom required for incoming meter• Fuse to Voltage loom LBWM6 required for up to six outgoing meters and 2 x LBWM6 looms required for 6 to 12 outgoing meters• CT to Meter Loom LBWCT required for each outgoing meter

30

Loadbank 250400A and 800A MCCBPanel Boards, Outgoingdevices up to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Description Product CodeFused Voltage Tap Off Loom LBWPFuse to Voltage loom for Incoming meter LBWIFuse to Voltage loom for up to 6 outgoing meters LBWM6CT to Meter Loom LBWCT

Please see our Metering Selection Charts in the following pages which detailall of the parts required in order to correctly meter the Loadbank 250 PanelBoard Range

Page 33: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

31

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Loadbank 250400A MCCB Panel Boards

Outgoing devicesup to 250A

Panel Board

LB406YA3LB412YA3LB418YA3

YB3 frame MCCB up to 250A

Meter Selection Chart - 250A/400A Form 3Panel Boards, Ci1 and Integra 1630 Meters

Left Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

LB1YA3

YB3 Frame MCCBup to 250A

Metering door kit

Cableways can be fitted to oneor both sides of the board andincoming enclosure as per your

cabling requirements.

If metering is required thenplease order a metering doorkit to suit the cableway.

Standard installation wouldrequire a metering door kit tobe fitted to just one side ofthe incoming enclosure for

the incoming meter.

SideCableway

Board

LECMD4LECM4LB406YA3

LECMD6LECM6LB412YA3

Metering door kit

SideCableway

Incoming Enclosure

LECMD3LECM3LB1YA3/LF1F2A

LECMD5LECM5LB1Y6/LB1F4A

Incoming Meter

LBWI x 1

Right Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 3 required per Meter:M53J-200/5M53J-250/5M63N-400/5

Step 1: Select Panel Board

Step 7: Select CT

Step 8: Select outgoing devices

Step 4: Select voltage tap off loom

Step 5: Select Meter

Step 6: Select CT to Meter Loom

Step 2: Select incoming enclosure and matching incoming device

Step 3: Select matching cableways and cableway metering door kits as required

Board

Incomingenclosure

Cableways andmetering doorkits can befitted to lefthand side ofrequired forextra cablingroom andmetering

Sidecablewaywith

meteringdoor kitfitted foroutgoingmeters

Cablewayand doorkit forincomingmeter

Ci1-01INT-1630-M-5-M-110

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

LB1Y6

YA6 Frame 400AMCCB

LF1F2A

200A Fuse Switch

LF1F4A

400A Fuse Switch

LECMD8LECM8LB418YA3

Page 34: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

32

Loadbank 250800A MCCB Panel BoardsOutgoing devicesup to 250A

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Panel Board

LB806YA3LB812YA3LB818YA3

YB3 frame MCCB up to 250A

Meter Selection Chart - 800A Form 3 PanelBoards, Ci1 and Integra 1630 Meters

Left Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

LB1Y6

YA6 frame 630A MCCB

LB1Y7

YA7 frame 800A MCCB

Metering door kit

Cableways can be fitted to oneor both sides of the board andincoming enclosure as per your

cabling requirements.

If metering is required thenplease order a metering doorkit to suit the cableway.

Standard installation wouldrequire a metering door kit tobe fitted to just one side ofthe incoming enclosure for

the incoming meter.

SideCableway

Board

LECMD4LECM4LB806YA3

LECMD6LECM6LB812YA3

Metering door kit

SideCableway

Incoming Enclosure

LECMD5LECM5LB1Y6

LECMD6LECM6LB1Y7

Incoming Meter

LBWI x 1

Right Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 3 required per Meter:M63N-400/5M63N-600/5M63N-800/5

Step 1: Select Panel Board

Step 7: Select CT

Step 8: Select outgoing devices

Step 4: Select voltage tap off loom

Step 5: Select Meter

Step 6: Select CT to Meter Loom

Step 2: Select incoming enclosure and incoming device

Step 3: Select matching cableways and cableway metering door kits as required

Board

Incomingenclosure

Cableways andmetering doorkits can befitted to lefthand side ofrequired forextra cablingroom andmetering

Sidecablewaywith

meteringdoor kitfitted foroutgoingmeters

Cablewayand doorkit forincomingmeter

Ci1-01INT-1630-M-5-M-110

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

LECMD8LECM8LB818YA3

Page 35: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

33

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

Loadbank 250400A and 800A MCCBPanel Boards, Outgoing

devices up to 250A

Panel Board

LF806YALF810YA

YA3/YB3 frame 3-pole MCCB up to250A with YA3NL neutral link

Meter Selection Chart - 800A Form 4 PanelBoards, Ci1 and Integra 1630 Meters

Left Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

Metering door kit

Cableways can be fitted to oneor both sides of the board andincoming enclosure as per your

cabling requirements.

If metering is required thenplease order a metering doorkit to suit the cableway.

Standard installation wouldrequire a metering door kit tobe fitted to just one side ofthe incoming enclosure for

the incoming meter.

SideCableway

Board

LECMD5LECM5LF806YA

LECMD8LECM8LF810YA

Metering door kit

SideCableway

Incoming Enclosure

LECMD5LECM5LF1F4A

LECMD8LECM8LF1F8A

Incoming Meter

LBWI x 1

Right Hand Cableway Outgoing

LBWP x 1

Up to 6 meters =LBWM6 x 1

6 to 12 meters =LBWM6 x 2

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 1 required per Meter:M3N1-35-100/5M3N1-35-125/5M3N1-35-160/5M3N1-35-200/5M3N1-35-250/5

Qty 3 required per Meter:M63N-400/5M63N-600/5M93L-800/5

Step 1: Select Panel Board

Step 7: Select CT

Step 8: Select outgoing devices

Step 4: Select voltage tap off loom

Step 5: Select Meter

Step 6: Select CT to Meter Loom

Step 2: Select incoming enclosure and incoming device

Step 3: Select matching cableways and cableway metering door kits as required

Board

Incomingenclosure

Cableways andmetering doorkits can befitted to lefthand side ofrequired forextra cablingroom andmetering

Sidecablewaywith

meteringdoor kitfitted foroutgoingmeters

Cablewayand doorkit forincomingmeter

Ci1-01INT-1630-M-5-M-110

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

Ci1-01INT-1630-M-5-M-110

1 x LBWCT per meter

LECMD5LECM5MMS15Y

LF1F4A

400A fuse switch

MMS15Y

YA6 frame MCCB up to 800A

LF1F8A

630A or 800A fuse switch

Page 36: Loadbank 125, 200 and 250 - Dorman Smith Switchgeardormansmithswitchgear.com/wp/downloads/...Dec2016.pdf · Dorman Smith Switchgear Limited Our product range begins with single-pole

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E Loadbank Panel Boards 11/2016

For further information or to request one of our product catalogues please contact us from the information above. E&OA. Whilstevery effort has been made to ensure accuracy, no liability is accepted for the consequences of any error or omissions in thiscatalogue. Dorman Smith Switchgear Ltd. reserve the right to change or amend any technical specification or product detailwithout prior notification.

Contact UsBRAINTREEDepartments: Customer Service, Logistics, Quality, Finance and HRDorman Smith Switchgear Limited Tel: +44 (0) 844 225 10638 Swinbourne Drive Fax: +44 (0) 844 225 1064Springwood Industrial Estate Email: [email protected], Essex www.dormansmithswitchgear.comCM7 2YG

PRESTONDepartments: Modis Estimation, Design/Product Management and TechnicalDorman Smith Switchgear Limited Tel: +44 (0) 1772 3253801 Nile Close Fax: +44 (0) 1772 325385Nelson Court Business Centre Email: [email protected] on Ribble www.dormansmithswitchgear.comPreston, Lancashire

PR2 2XU

DUBAIDorman Smith Switchgear LLC Tel: 00971 4 3470226P.O. Box 12872 Fax: 00971 4 3470002Dubai Email: [email protected]. www.dormansmithswitchgear.com