Little Red Book Issue 10

176
flexible and specialist cables the little red book Issue 10 FS FS cables cables

Transcript of Little Red Book Issue 10

FS CablesAlban Point, Alban Park, Hatfield Road,St. Albans, Herts AL4 0JX

flexible and specialist cables

the littlered book

Issue 10

Tel: 01727 840 841Fax: 01727 840 [email protected]

FS Cab

lesthe

little redbook

Issue 10

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

FS Cables Front Cover*:Layout 1 18/11/10 15:33 Page 1

How to Order: Payment Options:By phone

01727 840 841By fax01727 840 842By [email protected] hours are

Mon-Fri 8am to 6pm

Apply for a credit accountPlease ask your sales contact or visit thewebsite for an account application form

By payment cardWe accept most major credit, debit andpurchasing cards

Pre 9.00am / Pre 10.30am / Pre 12pm

and next working-day service available

Pre 10.30am / Pre 12pm and next

working-day service available

Pre 12pm and next working-day

service available

Next working-day service only

2-3 day service – please check at time

of order. Surcharges apply.

Note pallet services differ slightly, with the

earliest delivery option being Pre 10.30am.

Delivery Options: Express Delivery Options for Parcels and Small Drums:

• Next working-day deliveryis standard to mainland UK, free on orders over £100

• No cut-off time for orders – if we can ship it, we will

• Same-day deliveries,distance and time permitting

Many of the cables listed on the following pageswould be regarded as specialist within theelectrical industry. We regard them as standard.To support this we hold many of them in stockfor immediate despatch and in many cases, cutto the length you require – keeping your costsdown and reducing the environmental impactthrough reduced wastage.

With constant pressure to keep prices as low

as possible it is essential to maintain quality

and standards and this has become our mission.

The products offered are designed to do the job – your

job. Our commitment to service means you’ll receive

goods where and when you need them. With stock

items there is no order cut-off time, if we can ship it

we will. Next working-day delivery to UK mainland is

standard.

For special and modified products we offer realistic

lead times and sensible minimum order quantities.

Many stock products can also be modified to meet

specific requirements, for example armouring, over-

sheathing or duct grade for exterior use. Quantities on

these can often be as low as 100m. Please see pages

152-153 for more information.

TECHNICAL TABLES 154

COLOUR CODES 166

DATA

AUDIO

FIRE & SECURITY

TELEPHONE

LONDON UNDERGROUND

SIGNAL & CONTROL

HIGH TEMPERATURE

ROBOTICS

RUBBER & CRANE

THERMOCOUPLE

COAXIAL

HOME AUTOMATION HD

BUS

28

40

42

49

54

64

124

118

62

72

130

138

SPIRAL 142

GLANDS 144

TOOLS 148

SPECIAL MANUFACTURE 152

06

POWER CABLES 96

MARINE, OIL & GAS 102

www.fscables.com

Same Day Dispatch

There is no cut off time for orders received, if we can ship yourorder we will. For really urgent orders we can courier goods same-day into and around London, time permitting.

Modern Warehousing Facility

Over 55,000sq ft. of modern warehouse space featuring large,secure loading and unloading facilities and a full size weighbridge.

Commitment to Stock

Approximately 3000 product lines are held in stock for nextworking-day delivery, free on orders over £100.

Dedicated Export Department

Our export team FSC Global are on hand to handle overseasenquiries.

Custom Manufacture

If you need a cable manufactured to your own specification orstandard – talk to us. This can range from a printed or colouredjacket, right down to composite cables containing multipleelements.

Armouring and Over-Sheathing

Over-sheathing or steel wire armouring (SWA) to an existing cable with short lead times and for quantities as low as 100m.

Cut to Length

We cut to length on many product lines meaning you only buywhat you need – reducing both your costs and wastage.

Order Call-Off

Place an order and ‘call it off’ over time as required from ourwarehouse for just in time deliveries. This both fixes your costs and guarantees supply.

How to find us

FS Cables are based on Alban Park in St. Albans near J3 of the A1(M) or J22 of M25. If using Sat-Nav please use the postcode AL4 0JJ. Full turn by turndirections are available on the website www.fscables.com/map

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

4 SERVICE & SUPPORT

Many of the products listed in this catalogue are available in Low SmokeHalogen Free (LSHF), duct grade or SWA versions. These products are clearlyindicated on each page using this key:

Low Smoke Halogen Free Duct Grade SWA

Low Smoke Halogen Free

Duct Grade

Duct grade cables feature a tough, water resistant polyethylene (PE) jacket normally over thestandard jacket. They are suited for external installations where the cable may be runthrough ducts or clipped to buildings. They also offer excellent UV resistance.

SWA

SWA cables are ideal for fixed external installations or direct burial or where mechanicalprotection is required. The cable features protective steel armour wires and a PE, externalgrade PVC or Low Smoke Halogen Free outer jacket over the duct grade cable above.

3m³ smoke test to IEC 61034

Where all the products on a page are LSHF they are indicated with this header.

Low Smoke Halogen Free cables are those which emit minimal levels of toxic fumes andsmoke in the event of fire. It does not refer specifically to one particular type of material.

They are ideal for installations in confined areas such as computer rooms and other sensitiveenvironments, or areas that may be difficult to evacuate in the event of fire such as airports,hospitals or tube stations.

Standard PVC cables are made up of halogens which, when burnt, give off toxic gases suchas hydrogen chloride. When exposed to water – moisture in the air or fire sprinkler systemsfor example, hydrogen chloride forms highly noxious and corrosive hydrochloric acid.

Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk.

Compared to standard PVC which emits around 28% acid gas, LSHF cables produce less than0.5% HCl (Gases Evolved During Combustion BS EN 50267, IEC 60754-2).

Visibility through smoke emission is measured through a 3m³ smoke test (pictured) to IEC61034. Most LSHF cables produce very little smoke as opposed to standard PVC which givesoff dense black smoke.

Confusion still surrounds the terminology used to describe LSHF cables. While LSHF, LS0H,LSZH and 0HLS are the same, LSF (Low Smoke & Fume) is not. LSF covers data, control andflexible cables and is normally significantly inferior.

LSF cables are often modified PVC compounds and can still emit up to 22% HCl. They shouldbe regarded as only slightly better than PVC in the event of fire. The LSF cables in thiscatalogue can be regarded as better than standard PVC but are not halogen free.

If you are unsure of what you are buying, ask for written confirmation that the cable is LSHFthroughout.

At FS Cables, when you select LSHF, you can be confident you are buying a high quality LowSmoke Halogen Free cable.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

5HOW TO USE THIS CATALOGUE

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

6

1048AH 211215A 221502RHDA 461588AH 243076FHA 423077FHA 423078FHA 423079AHDA 453079E 453082A 433083AA 433084A 433085AA 433102A 443119A 447701H 447702H 447703H 447704H 448102H 178103H 178104 178105 178106H 178107 178108H 178110 178112 178115 178118 178125 178132H 568133H 568162HL 188163HL 188164H 188166 188167H 188168 188170 188175 188178 188185 188205HL 78312 DS8325 DS8345 DS8355 DS8442HL 78444H 78451HL 88471HDAL 7, 44, 57

Belden No. Page

8473HL 78618 98719HL 88720H 88723HDAL 12, 56, 60, 618728HL 128760HDL 8, 608761HDL 88762HDL 88769 138770HL 98771H 98772H 98773 138774H 138775 138776 138777HDAL 13, 56, 60, 618778HL 139156H 79182H 229207H 229248 DS9272H 229363 219365 219368HL 199402HL 199418HL 109463H 229491 79501HDL 11, 609502HL 119503HDL 11, 609504HDL 11, 609505HL 119506HL 11, 609507H 119508HL 119509 119510HL 119515H 119519HL 119525HL 119533L 109534HL 109535L 109536HL 109537 109538HL 109539 109891 22

Belden No. Page

9540HL 109541HL 109542 109543 109544 109545 109546 109550 119688H 229696 DS9728H 149729HDAL 14, 60, 619730HL 149731H 149732 149733 149734 149735 149736 149737 149738 149740HL 79744H 79750H 79767 139768H 139769 139773H 199774H 199829H 209830 209831 209832 209833 209834 209835 209836 209837 209838 209839 209841HDAL 15, 459842HDAL 15, 56, 60, 619843H 159844H 159860 229873HL 199874 199875 199876 199877 199879 199880 22

Belden No. Page

9901H 229907H 229913 DS9925 169927 169929 169931 169932 169933 169934 169935 169936 169937 169938 169939 209940 209941 209942 209943 209944 209945 209946 209947 209948 209949 209950 209990 DS9991 DSYM29560 45YR47205 43

Belden No. Page

Key

H = LSHF D = DUCTA = SWAL = LSF

Details of cables listed

as DS are available on

a separate datasheet.

LSF versions are available

from stock where indicated

In line with the rest

of the industry our LSF cables

are a modified PVC. If you

need halogen free cables

please specify LSHF.

FSC stock a wide range of genuine Belden cables and cost effective alternatives with PVC, Low Smoke Halogen Free and ductgrade jackets. Armoured versions are also available from stock.

DATA Belden Page Finder

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Unscreened Paired Data Cable

Construction - Two & Three Pair

Tinned copper stranded conductor, PVC insulation,cores twisted into pairs, pairs laid together, cleartape, PVC sheath.

Construction - Multicore

Tinned copper stranded conductor, PVC insulation,cores laid up, clear tape, PVC sheath.

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Colour Code: Chart 2 page 166

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Pairs mm2 kg/km mm C/C pF/m

2201PUYL 8442 1 22(7) 0.35 23 4.5 99

2201PUYH LSHF 1 22(7) 0.35 23 4.5 99

2001PUYL 8205 1 20(7) 0.56 26 5.0 81

2001PUYH LSHF 1 20(7) 0.56 26 5.0 81

1801PUYL 9740 1 18(16) 0.79 37 6.0 84

1801PUYH LSHF 1 18(16) 0.79 37 6.0 84

1601PUYL 8471 1 16(19) 1.34 56 7.0 108

1601PUYH LSHF 1 16(19) 1.34 56 7.0 108

1401PUYL 8473 1 14(42) 2.01 89 8.5 108

1401PUYH LSHF 1 14(42) 2.01 89 8.5 108

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Pairs mm2 kg/km mm C/C pF/m

2202PUYH 9744 NH 2 22(7) 0.35 39 6.2 84

1802PUYH 9156 NH 2 18(16) 0.79 71 8.5 84

2003PUY 9750 3 20(7) 0.56 67 7.6 80

2003PUYH LSHF 3 20(7) 0.56 67 7.6 80

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Cores mm2 kg/km mm C/C pF/m

2203CUY 9491 3 22(7) 0.35 32 4.9 85

2204CUYH 8444 NH 4 22(7) 0.35 34 5.1 111

1601PUYL

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

7Unscreened Pairs DATA

Construction - Single Pair

Tinned copper stranded conductor, PVC insulation on

standard cable, twisted into a pair, PVC sheath.

Technical Information

Voltage Rating: 22AWG -16AWG: 300V

14AWG: 600V

CE: 450/750V†

Colour Code: 22AWG -18AWG: Black & red16AWG -14AWG: Black & white

2204CUYH

Low Smoke Halogen Free

General purpose unscreened single and multipair cables with a small outer diameter, frequently used in audio, bus, data,security and instrumentation applications.

These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

† Applies to CE marked FSC branded stock only

Technical Information

Voltage Rating: 22AWG -16AWG: 300V14AWG: 600VCE: 450/750V†

Colour Code: Chart 3 page 166

1801POFPD

1601POFPL

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

8 DATA Screened Single Pair

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

General purpose foil screened single pair cables with a small outer diameter, frequently used in audio, data andinstrumentation applications. Polyethylene insulation results in lower signal loss than standard PVC insulation.

These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Single Pair Screened Data Cable

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

† Applies to CE marked FSC branded stock only

Construction - Screened Single Pair

Tinned copper conductor, polyethylene insulation,

twisted pair, aluminium/polyester foil screen, tinned

copper drain wire, PVC sheath. On duct grade cables

an additional UV stable LDPE jacket is put over the

standard PVC cables to give a high degree of

weather resistance.

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: +75°C

Nominal Impedance: 45 Ohms

Colour Code: Black & red

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Pairs mm2 kg/km mm pF/m

C/C C/S

Construction - Miniature 22AWG

Tinned copper conductors, polypropylene insulation,

twisted pair, aluminium/polyester foil screen tinned

copper drain wire, PVC sheath.

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Pairs mm2 kg/km mm pF/m

C/C C/S

2201POFRL 8451 1 22(7) 0.35 20 3.4 111 220

2201POFRH LSHF 1 22(7) 0.35 20 3.5 111 220

Technical Information

Voltage Rating: 22AWG -18AWG: 300V

16AWG -14AWG: 600V

CE: 450/750V†

Temperature Rating: 22AWG - 18AWG:+60°C

16AWG - 14AWG:+80°C

UL Style*: 2092

Colour Code: Black & clear (Black &

white on LSHF cables)

2201POFPL 8761 1 22(7) 0.35 25 4.6 79 154

2201POFPH LSHF 1 22(7) 0.35 25 4.6 79 154

2201POFPD DUCT 1 22(7) 0.35 27 6.2 79 154

2001POFPL 8762 1 20(7) 0.56 35 5.1 89 161

2001POFPH LSHF 1 20(7) 0.56 35 5.1 89 161

2001POFPD DUCT 1 20(7) 0.56 38 6.5 89 161

1801POFPL 8760 1 18(16) 0.79 45 6.0 79 144

1801POFPH LSHF 1 18(16) 0.79 45 6.0 79 144

1801POFPH06 VIOLET 1 18(16) 0.79 45 6.0 79 144

1801POFPD DUCT 1 18(16) 0.79 48 7.6 79 144

1601POFPL 8719 1 16(19) 1.34 84 7.9 75 144

1601POFPH LSHF 1 16(19) 1.34 84 7.9 75 144

1401POFP 8720 1 14(19) 1.92 109 9.0 79 154

1401POFPH LSHF 1 14(19) 1.92 109 9.0 79 154

Low Smoke Halogen Free Duct Grade

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

For use as audio or instrumentation wiring.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Three Core Overall Screened Data Cable

Construction - 22AWG, 20AWG & 18AWG

Tinned copper conductor, polyethylene insulation, cores

laid up, aluminium/polyester foil screen, tinned copper

drain wire, PVC sheath.

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: +60°C

UL Style*: 2093

Colour Code: Black, red & clear

Construction - 16AWG

Tinned copper conductor, polyethylene insulation,

cores laid up, aluminium/polyester foil screen, tinned

copper drain wire, PVC sheath.

Technical Information

Voltage Rating: 600V

Temperature Rating: +60°C

UL Style: 2107

Colour Code: Black, red & clear

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Cores mm2 kg/km mm pF/m

C/C C/S

2203COFP 8771 3 22(7) 0.35 35 5.1 75 134

2203COFPH LSHF 3 22(7) 0.35 35 5.1 75 134

2203COFPH06 VIOLET 3 22(7) 0.35 35 5.1 75 134

2003COFP 8772 3 20(7) 0.56 42 5.6 89 167

2003COFPH LSHF 3 20(7) 0.56 42 5.6 89 167

1803COFPL 8770 3 18(16) 0.79 56 6.3 79 157

1803COFPH LSHF 3 18(16) 0.79 56 6.3 79 157

Part No. Alt. to No. of AWG CSA Weight O/D Capacitance Belden Cores mm2 kg/km mm pF/m

C/C C/S

1603COFP 8618 3 16(19) 1.34 96 8.3 85 151

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

2203COFPH06

1803COFPL

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

9Screened Triple DATA

Low Smoke Halogen Free

† Applies to CE marked FSC branded stock only

1804COFYL

2415COFYL

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

10 DATA Overall Screened Multicores

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Uses include RS232, instrumentation and sound applications where balanced lines are not required.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Overall Screened Multicored Data Cable RS232

Construction - 24AWG

Tinned copper conductor 24(7) AWG,0.22mm2, PVC insulation. Cores laid up,overall aluminium/polyester foil screen, tinnedcopper drain wire (24AWG), PVC sheath.

Technical Information - 24AWG & 18AWG

Voltage Rating: 300VCE: 450/750V†

Temperature Rating: +80°CCapacitance: Up to 8 core: Core to core 108pF/m, Core to screen 213pF/m

Above 8 core: Core to core 98pF/m, Core to screen 180pF/mUL Style*: 2464Colour Code: Up to 10 core Chart 1 page 166

Above 10 core Chart 2 page 166

A full range of 22AWG cored cables is available from stock with LSHF and duct grade versions available to order.*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Construction - 18AWG

Tinned copper conductor 18(19) AWG, 0.79mm2, PVC insulation, colour chart 1, page 166. Cores laid up,

overall aluminium/polyester foil screen, tinned copper drain wire (20AWG), PVC sheath.

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

Part No. Alt. to Belden No. of Cores Weight kg/km O/D mm

1804COFYL 9418 4 78 6.21804COFYH LSHF 4 78 6.2

Low Smoke Halogen Free

2403COFYL 9533 3 26 4.22404COFYL 9534 4 33 4.72404COFYH LSHF 4 33 4.72405COFYL 9535 5 35 4.82406COFYL 9536 6 42 5.32406COFYH LSHF 6 42 5.32407COFY 9537 7 45 5.32408COFYL 9538 8 49 5.72408COFYH LSHF 8 49 5.72409COFY 9539 9 60 6.22410COFYL 9540 10 61 6.22410COFYH LSHF 10 61 6.22415COFYL 9541 15 83 7.32415COFYH LSHF 15 83 7.32420COFY 9542 20 104 8.02425COFY 9543 25 139 8.62430COFY 9544 30 152 9.72440COFY 9545 40 195 10.92450COFY 9546 50 238 12.5

† Applies to CE marked FSC branded stock only

Construction - 24AWG

Tinned copper conductor 24(7) AWG,

0.22mm2, PVC insulation. Twisted into

pairs, overall aluminium/polyester foil

screen, tinned copper drain wire

(24AWG), PVC sheath.

Construction - 22AWG

Tinned copper conductor 0.34mm2, PVC insulation. Twisted into pairs, overall aluminium/polyester foil screen,

tinned copper drain wire (24AWG), PVC sheath.

Widely used for computers, point of sale, control systems and RS232 applications. This is a general purpose overallscreened twisted paired cable.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Overall Screened Multipair Data Cable RS232

Part No. Alt. to No. of Weight O/D Belden Pairs kg/km mm

Part No. Alt. to No. of Weight O/D Belden Pairs kg/km mm

2406POFYD DUCT 6 93 9.62407POFY 9507 7 80 7.52407POFYH LSHF 7 80 7.52408POFYL 9508 8 97 8.22408POFYH LSHF 8 97 8.22409POFY 9509 9 104 8.52410POFYL 9510 10 119 9.32410POFYH LSHF 10 119 9.32415POFY 9515 15 160 10.52415POFYH LSHF 15 160 10.52419POFYL 9519 19 192 11.42419POFYH LSHF 19 192 11.42425POFYL 9525 25 243 12.82425POFYH LSHF 25 243 12.82450POFY 9550 50 460 18.0

Part No. AWG No. of Pairs Weight kg/km O/D mm

2202POFY 22 2 38 5.82203POFY 22 3 50 6.12204POFY 22 4 71 6.72205POFY 22 5 81 7.42206POFY 22 6 88 7.92209POFY 22 9 123 9.12211POFY 22 11 160 9.92215POFY 22 15 190 10.92219POFY 22 19 234 12.8

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Technical Information - 24AWG & 22AWG

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +80°CCapacitance: 1 Pair: Core to core 131pF/m

Core to screen 243pF/m24AWG: Core to core 98pF/m

Core to screen 164pF/m22AWG: Core to core 114pF/m approx

Core to screen 206pF/m approx UL Style*: 2464Colour Code: Chart 3 page 166

2401POFYL 9501 1 21 3.92401POFYH LSHF 1 21 3.92401POFYD DUCT 1 44 6.22402POFYL 9502 2 32 5.62402POFYH LSHF 2 32 5.62403POFYL 9503 3 49 5.92403POFYH LSHF 3 49 5.92403POFYD DUCT 3 66 8.12404POFYL 9504 4 54 6.72404POFYH LSHF 4 54 6.72404POFYD DUCT 4 72 8.92405POFYL 9505 5 66 7.42405POFYH LSHF 5 66 7.42406POFYL 9506 6 72 7.42406POFYH LSHF 6 72 7.4

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

11Overall Screened Multipairs DATA

2206POFY

2403POFYD

Low Smoke Halogen Free Duct Grade

† Applies to CE marked FSC branded stock only

2202PIFRA

2202PIFR

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

12 DATA Individually Screened Two Pair

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Used extensively in the security industry for CCTV applications including telemetry. Also suitable for computer andinstrumentation applications where it is important to provide a high level of screening from external sources, together withlow levels of cross talk between pairs.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Individually Screened Two Pair Data Cable 22AWG

Construction - Individually Screened

Tinned copper conductor 22(7) AWG 0.35mm2,

polypropylene insulation, twisted into pairs, each pair

aluminium/polyester foil screened, common tinned

copper drain wire (24AWG), PVC sheath. The duct

grade version has a black UV stable polyethylene

sheath over the standard PVC cable to provide a high

degree of weather resistance, while the armoured

version is protected by heavy galvanised steel wires

and an external grade sheath.

Construction - Individually and Overall Screened

Tinned copper conductor 22(7) AWG 0.35mm2,

polypropylene insulation, twisted into pairs, each pair

individually screened with aluminium/polyester foil and

24AWG tinned copper drain wire, overall aluminium/

polyester foil and 24AWG tinned copper drain wire,

PVC sheath.

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 45 OhmsCapacitance: Core to core 115pF/m

Core to screen 203pF/mColour Code: Red/Black & Green/White

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 45 OhmsCapacitance: Core to core 115pF/m

Core to screen 203pF/mUL Style: 2717Colour Code: Red/Black & Green/White

Part No. Alt. to No. of AWG Weight O/DBelden Pairs kg/km mm

2202PIFR 8723 2 22(7) 32 4.2

2202PIFRW WHITE 2 22(7) 32 4.2

2202PIFRL LSF 2 22(7) 32 4.2

2202PIFRH LSHF 2 22(7) 32 4.2

2202PIFRH06 VIOLET 2 22(7) 32 4.2

2202PIFRD DUCT 2 22(7) 50 6.2

2202PIFRA SWA 2 22(7) 210 9.8

Part No. Alt. to No. of AWG Weight O/DBelden Pairs kg/km mm

2202PTFRL 8728 2 22(7) 42 5.2

2202PTFRH LSHF 2 22(7) 42 5.2

Low Smoke Halogen Free Duct Grade SWA

† Applies to CE marked FSC branded stock only

2206PIFRL

2203PIFRD

Construction - 22AWG

Tinned copper conductor 22(7) AWG, 0.35mm2.

Polypropylene insulated. Twisted into pairs, each pair

aluminium/polyester foil screened, tinned copper drain

wire (24AWG), PVC sheath.

Technical Information

Voltage Rating: 300V

CE: 450/750V†

Temperature Rating: +80°CNominal Impedance: 50 OhmsCapacitance: Core to core 98pF/m

Core to screen 180pF/mUL Style*: 2919Colour Code: Chart 3 page 166

These cables are used extensively within security, computer and instrumentation applications. Many sizes are also usedwithin the audio field as snake cables where the individual screening of pairs reduces cross talk.

The 3 pair version is particularly popular within the security industry for CCTV and access control systems.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Individually Screened Multipair Data Cable 22AWG

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of AWG Weight O/DBelden Pairs kg/km mm

2203PIFRL 8777 3 22(7) 70 7.0

2203PIFRH LSHF 3 22(7) 70 7.0

2203PIFRA SWA 3 22(7) 330 11.1

2203PIFRD DUCT 3 22(7) 96 8.6

2206PIFRL 8778 6 22(7) 123 9.2

2206PIFRH LSHF 6 22(7) 123 9.2

2209PIFR 8774 9 22(7) 177 10.6

2209PIFRH LSHF 9 22(7) 177 10.6

2211PIFR 8775 11 22(7) 201 11.8

2212PIFR 9768 12 22(7) 226 12.1

2212PIFRH LSHF 12 22(7) 226 12.1

2215PIFR 8776 15 22(7) 290 13.9

2217PIFR 9769 17 22(7) 331 14.7

2219PIFR 8769 19 22(7) 348 15.3

2227PIFR 8773 27 22(7) 502 18.0

2237PIFR 9767 37 22(7) 739 20.3

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

13Individually Screened Multipairs DATA

Low Smoke Halogen Free Duct Grade SWA

† Applies to CE marked FSC branded stock only

2406PIFF

2402PIFFD

Construction - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm2,

foam polyolefin insulation. Twisted into pairs, each

pair aluminium/polyester foil screened, tinned

copper drain wire (24AWG), PVC sheath.

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 100 OhmsCapacitance: Core to core 41 pF/m

Core to screen 76 pF/mUL Style*: 2463Colour Code: Chart 3 page 166

For RS422 connection and any other application requiring both low capacitance and excellent isolation between pairs. Usedfor CAD/CAM and many other industrial applications with high data rates.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422

Some of the above cables are also available in armoured, duct grade or Low Smoke Halogen Free versions evenwhere not listed. Please call for details.* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or

approved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of Weight O/DBelden Pairs kg/km mm

2402PIFFL 9729 2 66 6.7

2402PIFFH LSHF 2 66 6.7

2402PIFFD DUCT 2 79 10.2

2402PIFFA SWA 2 178 12.6

2403PIFFL 9730 3 80 8.5

2403PIFFH LSHF 3 80 8.5

2404PIFF 9728 4 97 9.2

2404PIFFH LSHF 4 97 9.2

2406PIFF 9731 6 137 10.7

2406PIFFH LSHF 6 137 10.7

2409PIFF 9732 9 203 12.4

2411PIFF 9733 11 226 14.6

2412PIFF 9734 12 242 14.6

2415PIFF 9735 15 300 16.3

2417PIFF 9736 17 326 17.1

2419PIFF 9737 19 348 17.1

2427PIFF 9738 27 557 20.3

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

14 DATA Individually Screened Multipairs

Low Smoke Halogen Free Duct Grade SWA

† Applies to CE marked FSC branded stock only

> Single pair 2401POHPL is supplied with blue & white cores (Western Electric colour code, page 166) asstandard or black & white cores as special order. Please specify if you have a preference at time of order.

+ 2402POHP is an alternative to Allen Bradley type 1747CD* UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or

approved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of Weight O/DBelden Pairs kg/km mm

2401POHPL> 9841 1 64 5.8

2401POHPD DUCT 1 92 8.4

2401POHPH LSHF 1 64 5.8

2401POHPA SWA 1 192 9.6

2402POHPL+ 9842 2 95 8.6

2402POHPD DUCT 2 118 11.1

2402POHPH LSHF 2 95 8.6

2402POHPA SWA 2 251 12.5

2403POHP 9843 3 108 9.2

2403POHPH LSHF 3 108 9.2

2404POHP 9844 4 125 9.9

2404POHPH LSHF 4 125 9.9

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels ofscreening to provide high speed, interference free, data transmission.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Overall Foil & Braid Screened Paired Data Cable 24AWG RS485 Low Capacitance

Construction - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm2,

polyethylene insulation. Twisted into pairs, overall

aluminium/polyester foil screened, tinned copper

drain wire (24AWG), overall tinned copper braid

(90%). PVC sheath.

2402POHPD

2401POHPH

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +80°CNominal Impedance: 120 OhmsCapacitance: Core to core 42 pF/m

Core to screen 76 pF/mUL Style*: 2919Colour Code: Chart 5 page 166

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

15Overall Foil & Braid Screened Pairs DATA

Low Smoke Halogen Free Duct Grade SWA

† Applies to CE marked FSC branded stock only

Construction - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm2, foam

polyolefin insulation. Cores laid up, overall

aluminium/polyester foil screen, tinned copper drain

wire (24AWG), overall tinned copper braid (65%). PVC

sheath.

A range of high performance cables for use over extended distances at high data rates for RS232 and RS423 applications. Also well

suited to industrial measurement where low signal distortion is required. These cables are widely used in CAD/CAM applications.

Overall Foil & Braid Screened Cored Data Cable RS232 & RS423

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of Weight O/DBelden Cores kg/km mm

2402CODF N/A 2 33 4.7

2403CODF 9925 3 38 5.5

2404CODF 9927 4 45 5.8

2405CODF 9929 5 51 6.3

2406CODF 9931 6 58 6.7

2407CODF 9932 7 62 6.8

2408CODF 9933 8 68 7.1

2409CODF 9934 9 77 7.6

2410CODF 9935 10 83 7.8

2415CODF 9936 15 107 8.9

2425CODF 9937 25 165 11.3

2437CODF 9938 37 207 12.7

Technical Information

Voltage Rating: 300V Temperature Rating: +80°CCapacitance: Core to core 40 pF/m

Core to screen 72 pF/mUL Style*: 2919Colour Code: Up to 10 core

Chart 1 page 166Above 10 core Chart 2 page 166

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

16 DATA Overall Foil & Braid Screened Cores

2405CODF

+ Twelve pairs plus one conductor.*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of Weight O/DBelden Pairs kg/km mm

2402PODF 8102 2 61 6.8

2402PODFH LSHF 2 61 6.8

2403PODFL 8103 3 71 7.1

2404PODF 8104 4 80 7.6

2405PODF 8105 5 89 7.9

2406PODF 8106 6 104 8.6

2406PODFH LSHF 6 104 8.6

2407PODF 8107 7 106 8.6

2408PODF 8108 8 118 9.3

2408PODFH LSHF 8 118 9.3

2410PODF 8110 10 150 10.9

2412PODF 8112 12.5+ 165 11.8

2415PODF 8115 15 196 12.6

2418PODF 8118 18 235 13.6

2419PODF N/A 19 248 13.6

2425PODF 8125 25 297 16.1

Construction - 24AWG

Tinned copper conductor 24(7) AWG, 0.22mm2,

foam polyolefin insulation. Twisted into pairs, overall

aluminium/polyester foil screen, tinned copper drain

wire (24AWG), overall tinned copper braid (65%).

PVC sheath.

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +80°CNominal Impedance: 100 OhmsCapacitance: Core to core 41 pF/m

Core to screen 72 pF/mUL Style*: 2919Colour Code: Chart 5 page 166

A range of high performance cables for use over extended distances at high data rates for RS232 and RS422 applications.Also well suited to industrial measurement applications where low signal distortion is required.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Overall Foil & Braid Screened Paired Data Cable RS232 & RS422

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

17Overall Foil & Braid Screened Pairs DATA

2406PODF

Low Smoke Halogen Free

† Applies to CE marked FSC branded stock only

2402PTMFH

Construction - 24AWG

Tinned copper conductor 24(7) AWG 0.22mm2, foam

polyolefin insulation. Twisted into pairs, each pair

individually aluminium/polyester foil screened with an

overall aluminium/polyester foil screen, tinned copper

drain wire (24AWG), overall tinned copper braid

(65%). PVC sheath.

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 100 OhmsCapacitance: Core to core 41 pF/m

Core to screen 72 pF/mUL Style*: 2493Colour Code: Chart 3 page 166

Designed for RS422 data connections, this cable combines low capacitance insulation with very high levels of screeningto provide high speed, interference free, data transmission.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Individual & Overall Screened Multipair Data Cable 24AWG RS422 Low Capacitance

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

Part No. Alt. to No. of Weight O/DBelden Pairs kg/km mm

2402PTMFL 8162 2 92 8.7

2402PTMFH LSHF 2 92 8.7

2403PTMFL 8163 3 104 9.1

2403PTMFH LSHF 3 104 9.1

2404PTMF 8164 4 121 9.8

2404PTMFH LSHF 4 121 9.8

2406PTMF 8166 6 150 11.3

2407PTMF 8167 7 158 11.3

2407PTMFH LSHF 7 158 11.3

2408PTMF 8168 8 177 12.0

2410PTMF 8170 10 245 15.0

2415PTMF 8175 15 325 17.0

2418PTMF 8178 18 354 17.5

2425PTMF 8185 25 522 21.0

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

18 DATA Individual & Overall Screened Multipairs

Low Smoke Halogen Free

† Applies to CE marked FSC branded stock only

1802PIFYL

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Widely used in monitoring, computer, instrumentation and audio applications where the individually screened pairs reducecross talk. Reduced losses are achieved through the use of 20AWG or 18AWG conductors making this cable ideal for long runs.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Individually Screened Multipair Data Cable 20AWG & 18AWG

Construction - 20AWG

2 Pair - Tinned copper conductor 20(7)AWG, 0.56mm2, PVC

insulated, twisted into pairs, each pair aluminium/polyester

foil screened, tinned copper drain wire (22AWG). PVC sheath.

Multipair - Tinned copper conductor 20(7)AWG, 0.56mm2,

polypropylene insulated. Twisted into pairs, each pair

aluminium/polyester foil screened, tinned copper drain

wire (22AWG), PVC sheath.

2009PIFP

Part No. Alt. to No. of Weight O/D Capacitance inBelden Pairs kg/km mm pF/m

C/C C/S

2002PIFYL 9402 2 76 7.6 180 3122002PIFYH LSHF 2 76 7.6 180 3122003PIFPL 9873 3 104 8.4 98 1802003PIFPH LSHF 3 104 8.4 98 1802006PIFP 9874 6 182 10.9 98 1802009PIFP 9875 9 270 13.6 98 1802011PIFP 9876 11 302 15.2 98 1802012PIFP 9877 12 322 15.2 98 1802015PIFP 9879 15 384 17.0 98 180

Part No. Alt. to No. of Weight O/D Capacitance inBelden Pairs kg/km mm pF/m

C/C C/S

1802PIFYL 9368 2 103 9.6 187 3351802PIFYH LSHF 2 103 9.6 187 3351803PIFP 9773 3 139 10.3 98 1801803PIFPH LSHF 3 139 10.3 98 1801806PIFP 9774 6 259 14.3 98 1801806PIFPH LSHF 6 259 14.3 98 180

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

+ Impedence figure not applicable on two pair version

Construction - 18AWG

2 Pair - Tinned copper conductor 18(19)AWG, 0.96mm2,PVC insulated, twisted into pairs, each pairaluminium/polyester foil screened, tinned copper drain wire(20AWG). PVC sheath.

Multipair - Tinned copper conductor 18(19)AWG,0.96mm2, polypropylene insulated. Twisted into pairs, eachpair aluminium/polyester foil screened, tinned copper drainwire (20AWG), PVC sheath.

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 45 Ohms+

UL Style*: 2pair: 2464Above 2pair: 2919

Colour Code: 2pair: Red/Black & Green/WhiteAbove 2pair: Chart 3 page 166

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

19Individually Screened Multipairs DATA

Technical Information

Voltage Rating: 300V CE: 450/750V†

Temperature Rating: +60°CNominal Impedance: 45 Ohms+

UL Style: 2pair: 2464Above 2pair: 2919

Colour Code: 2pair: Black/RedAbove 2pair: Chart 3 page 166

† Applies to CE marked FSC branded stock only

2402PODP

2209CODY

Overall Foil & Braid Screened Data Cables RS232 & RS422

A range of high performance cables for use over extended distances at high data rates for RS232 applications. They arealso well suited to industrial measurement where low signal distortion is required.

The 24AWG foil & braid twisted paired cable runs over RS232 & RS422 protocols. Excellent dual screening enables this cableto carry signals over long distances with minimum distortion.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Construction - 22AWG

Tinned copper conductor 22(7) AWG,0.35mm2, semi rigid PVC insulation. Coreslaid up, overall. Aluminium/polyester foilscreen, tinned copper drain wire (24AWG),overall tinned copper braid (65%). PVCsheath

Part No. Alt. to No. of Weight O/DBelden Cores kg/km mm

2203CODY 9939 3 41 5.12204CODY 9940 4 48 5.52205CODY 9941 5 55 5.82206CODY 9942 6 63 6.22207CODY 9943 7 65 6.32208CODY 9944 8 74 6.62209CODY 9945 9 85 7.12210CODY 9946 10 94 7.62215CODY 9947 15 130 8.62225CODY 9948 25 189 10.42237CODY 9949 37 238 11.72250CODY 9950 50 348 14.1

Part No. Alt. to No. of Weight O/DBelden Pairs kg/km mm

2402PODP 9829 2 61 7.42402PODPH LSHF 2 61 7.42403PODP 9830 3 70 7.72404PODP 9831 4 79 8.42405PODP 9832 5 84 8.62406PODP 9839 6 97 9.32407PODP 9833 7 103 9.42409PODP 9834 9 130 10.62410PODP 9835 10 140 11.52412PODP 9836 12 155 11.82418PODP 9837 18 225 14.42425PODP 9838 25 295 17.1

Construction - 24AWG

Tinned copper conductor 24(7) AWG,0.22mm2, polyethylene insulation. Twisted intopairs, overall aluminium/polyester foil screen,tinned copper drain wire (24AWG), overalltinned copper braid (65%). PVC sheath.

Technical InformationVoltage Rating: 300V Temperature Rating: +80°CNominal Impedance: 100 OhmsCapacitance: Up to 5core - Core to core 121 pF/m,

Core to screen 220 pF/mAbove 5core -Core to core 115 pF/m

Core to screen 207 pF/mUL Style*: 2464Colour Code: Up to 10 core: Chart 1 page 166

Above 10 core: Chart 2 page 166

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to orapproved by UL. If you require UL approved versions please tell us when you first enquire.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

20 DATA Overall Foil & Braid Screened Pairs & Cores

Low Smoke Halogen Free

Technical InformationVoltage Rating: 300VTemperature Rating: +80°CNominal Impedance: 100 OhmsCapacitance: Core to core 51 pF/m

Core to screen 90 pF/mUL Style*: 2919Colour Code: Chart 5 page 166

Industrial process control and instrumentation cables suitable for use in a wide variety of industries from nuclear energygeneration to security and access control.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Part No. Alt. to No. of Weight O/D Voltage Belden Pairs kg/km mm

1802PTFNH 1048A LSHF 2 115 9.9 600V

Construction - Individually and Overall Screened Pairs

Plain copper conductor 18(7) AWG 0.88mm2, Low Smoke Halogen Free insulation with a nylon skin.

Conductors twisted into pairs, black and white numbered pairs, each pair individually aluminium/polyester foil

screened with a 20(7) AWG tinned copper drain wire, pairs laid up with isolated screens. Overall screen is

aluminium/polyester foil screen with 20(7) AWG tinned copper drain wire. Low Smoke Halogen Free sheath.

Part No. No. of Weight O/D Voltage Cores kg/km mm

1403COBYH 3 128 9.1 600V

Construction - Overall Screened Triple 14AWG

3 x 14(41) AWG, 2.0mm2, plain copper conductor, (colour code: black, white, red) Low Smoke Halogen Free

insulation, polyester tape, 90% tinned copper wire braid, black Low Smoke Halogen Free sheath.

Construction - Overall Screened Triple 22 & 18AWG

Tinned copper conductor, colour coded PVC insulation, black, red, white. Aluminium/polyester foil screen

with drain wire. PVC jacket.

1802PTFNH

Instrumentation, Process control & PLTC

Part No. Alt. to No. of AWG CSA Weight O/D VoltageBelden Cores mm2 kg/km mm

2203COFY 9363 3 22(7) 0.35 39 5.3 300V

1803COFY 9365 3 18(16) 0.79 64 6.3 300V

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

21Instrumentation, Process Control & PLTC DATA

200278DPH

2202PTDP

IBM Cables, Ethernet Cables & Twin-Ax Cables

Although many of these cables are no longer used on new installations we still have stock of some types which can be usefulif you are extending an existing system. Please call us to discuss your needs.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Part No. Reference Alt. to IBM Description O/DBelden Part No. mm

IBM Cables

2202PTDP IBM Type 1A 9688 4716748 2 x 2 x 22AWG 7.8 x 12

2202PTDPH IBM Type 1A LSHF 4716734 2 x 2 x 22AWG 7.8 x 12

2404PUY IBM Type 3 - - 4 x 2 x 22AWG 4.7

2602PODF IBM Type 6 1215A 4716743 2 x 2 x 26(7)AWG 8.7

2601PODF IBM Type 7 - 4716746 1 x 2 x 26(7)AWG 6.3

Part No. Alt. to Description Stranding Capacitance pF/m O/DBelden AWG C/C mm

Ethernet 10BASE5

1201AXDD 9880 Trunk 12(1) 85 10.3

2004PTMFH 9901 LSHF Grey AUI Drop 4 x 2 x 20(7) 55 10.7

2203PTMP 9891 Blue AUI Drop 3 x 2 x 22(7) 55 9.9

+ 1 x 2 x 20(7)

Part No. Alt. to Description Stranding Capacitance pF/m O/DBelden AWG C/C mm

Ethernet 10BASE2

2001AXD 9907 Thinnet 20(19) 86 4.6

2001AXDH LSHF Thinnet 20(19) 86 4.6

Part No. Alt. to AWG O/D Cap. pF/m Imp. ColourBelden mm C/C Ohms

Twin-Ax

220215FF 9182 22(19) 8.9 29 150 Black

220215FFH LSHF 22(19) 8.9 29 150 Black

200278BP 9272 20(7) 6.2 65 78 Blue

200278BPH LSHF 20(7) 6.2 65 78 Blue

200278DP 9463 20(7) 6.2 65 78 Blue

200278DPH LSHF 20(7) 6.2 65 78 Blue

200210DP 9207 20(7) 8.4 51 100 Black

200210DPH LSHF 20(7) 8.4 51 100 Black

160212DP 9860 16(1) 11.2 36 124 Black

Twin-Axial cables were originally developed for I/O switching & process control applications. Now widely usedin commercial applications such as building management systems. Most types are also stocked in Low SmokeHalogen Free versions as well as PVC.

If the Twin-Ax you are looking for is not shown please call us.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

22 DATA IBM, Ethernet & Twin-Ax Cables

Low Smoke Halogen Free

9960050400

9950020408

Part No. Cores x Weight O/D Insulation Screen Colourmm2 kg/km mm Type Type

9950020408 4 x 0.22 29 4.6 PE Foil Orange

9950020608 6 x 0.22 36 6.2 PE Foil Orange

9950030408 4 x 0.34 35 6.0 PE Foil Orange

9950009405 4 x 0.09 21 4.0 PVC Foil Grey

Part No. Cores x Weight O/D Insulation Screen Colourmm2 kg/km mm Type Type

39300112PUR 12 x 0.055 32 4.3 PVC Braid Black

9960020400 4 x 0.22 34 4.7 PVC Braid Black

9960050400 4 x 0.50 65 6.8 PVC Braid Black

Construction - Foil Screened

Tinned or plain copper conductor, colour coded PE or

PVC insulation, polyester tape, tinned copper drain

wire, inward facing aluminium/polyester tape, tough

polyurethane gloss jacket.

Construction - Braid Screened

Tinned or plain copper conductor, colour coded cold

resistant PVC insulation, polyester tape, high

coverage tinned copper wire braid, tough

polyurethane gloss jacket.

Other sizes, colours and insulation types can be supplied for quantities as low as 2km. Cable can be printedwith your company name or message and phone number. See pages 152-153 for details.

Full specifications sheets are available on the above giving electrical characteristics and colour codes.

Technical Information

Voltage Rating: 300V

Temperature Rating: -30ºC to +80ºC

Max Conductor Resistance:

0.09mm2 (28AWG): 232 Ohms per km

0.22mm2 (24AWG): 92 Ohms per km

0.34mm2 (22AWG): 57 Ohms per km

Technical Information

Voltage Rating: 300V

Temperature Rating: -30ºC to +80ºC

Max Conductor Resistance:

0.055mm2 (30AWG): 367 Ohms per km

0.5mm2 (20AWG): 39 Ohms per km

Developed for accurate signal transmission in physically demanding conditions the FSC range of transducer and load cellcables cover all the popular types. The ultra tough polyurethane jacket provides excellent protection against both waterand mechanical damage. To guard against the effects of nearby power cables or other sources of electromagnetic radiationa choice of either a foil screen with drain wire or a high density tinned copper wire braid is offered.

Transducer & Load Cell Cables

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

23Transducer & Load Cell Cables DATA

The benefits of running voice, data or video over the same cabling system are considerable. The versatility of the lateststructured wiring systems ensure confidence that future needs can be easily met with minimal expense or inconvenienceto other network users.

The majority of installations use unshielded twisted pair (UTP) cables. Baluns allow RGB video signals to be transmitted usingUTP, saving the cost of running dedicated wiring for many dealing room systems.

Where higher performance cables for ATM, multimedia and similar applications are required, please call us for the latestinformation.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Cat5E UTP, Cat5E Screened, Cat 6A Screened & Unscreened & Cat 7 Screened

Part No. Description Colour Weight O/D Pack RJ45 RJ45 Strainkg/km mm Lengths Part No. Relief Boot

† Not to Cat-5E standard

* This cable is an alternative to Belden 1588A

Cat-5E UTP Solid ConductorsC51HR† 1 x 2 x 24AWG UTP LSHF Grey 12 2.8 Reel - -C5E2HR* 2 x 2 x 24AWG UTP LSHF Grey 22 4.4 Reel - -C5EB 4 x 2 x 24AWG UTP PVC Grey 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EC 4 x 2 x 24AWG UTP PE Black 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5ECB 4 x 2 x 24AWG UTP PE Black 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5ER 4 x 2 x 24AWG UTP PVC Grey 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EHB 4 x 2 x 24AWG UTP LSHF Violet 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EHR 4 x 2 x 24AWG UTP LSHF Grey 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5ER-Shotgun 4 x 2 x 24AWG UTP PVC Grey 74 10.8 x 6.2 Reel RJ45UTPP RJ45UTPP-STC5EHR-Shotgun 4 x 2 x 24AWG UTP LSHF Orange 74 10.8 x 6.2 Reel RJ45UTPP RJ45UTPP-ST

Cat-5E UTP Conductors (Patch) StrandedC5EPB00 4 x 2 x 24AWG UTP PVC Black 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB01 4 x 2 x 24AWG UTP PVC Blue 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB03 4 x 2 x 24AWG UTP PVC Red 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB04 4 x 2 x 24AWG UTP PVC White 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB05 4 x 2 x 24AWG UTP PVC Grey 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB06 4 x 2 x 24AWG UTP PVC Violet 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB07 4 x 2 x 24AWG UTP PVC Pink 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB08 4 x 2 x 24AWG UTP PVC Orange 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB09 4 x 2 x 24AWG UTP PVC Yellow 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPB10 4 x 2 x 24AWG UTP PVC Green 36 5.5 305m Box RJ45UTPP RJ45UTPP-STC5EPHR00 4 x 2 x 24AWG UTP LSHF Black 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR01 4 x 2 x 24AWG UTP LSHF Blue 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR03 4 x 2 x 24AWG UTP LSHF Red 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR04 4 x 2 x 24AWG UTP LSHF White 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR05 4 x 2 x 24AWG UTP LSHF Grey 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR06 4 x 2 x 24AWG UTP LSHF Violet 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR07 4 x 2 x 24AWG UTP LSHF Pink 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR08 4 x 2 x 24AWG UTP LSHF Orange 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR09 4 x 2 x 24AWG UTP LSHF Yellow 36 5.5 Reel RJ45UTPP RJ45UTPP-STC5EPHR10 4 x 2 x 24AWG UTP LSHF Green 36 5.5 Reel RJ45UTPP RJ45UTPP-ST

24 DATA Structured Wiring

Low Smoke Halogen Free

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

25Structured Wiring DATA

Part No. Description Colour Weight O/D Pack RJ45 RJ45 Strainkg/km mm Lengths Part No. Relief Boot

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

Cat 5E FTP Overall Foil Screened Solid Conductors

C5EFR 4 x 2 x 24AWG FTP PVC Grey 40 6.0 Reel RJ45STPP RJ45UTPP-ST

C5EFHR 4 x 2 x 24AWG FTP LSHF Orange 40 6.0 Reel RJ45STPP RJ45UTPP-ST

Cat 5E FTP Overall Foil Screened Stranded Conductors (Patch)

C5EPFB01 4 x 2 x 24AWG FTP PVC Blue 40 6.0 305m Box RJ45STPP RJ45UTPP-ST

C5EPFB03 4 x 2 x 24AWG FTP PVC Red 40 6.0 305m Box RJ45STPP RJ45UTPP-ST

C5EPFB05 4 x 2 x 24AWG FTP PVC Grey 40 6.0 305m Box RJ45STPP RJ45UTPP-ST

C5EPFB10 4 x 2 x 24AWG FTP PVC Green 40 6.0 305m Box RJ45STPP RJ45UTPP-ST

Cat 6 UTP Solid Conductors

C6B 4 x 2 x 24AWG UTP PVC Grey 43 6.3 305m Box - -

C6R 4 x 2 x 24AWG UTP PVC Grey 43 6.3 Reel - -

C6HB 4 x 2 x 24AWG UTP LSHF Violet 43 6.3 305m Box - -

C6HR 4 x 2 x 24AWG UTP LSHF Grey 43 6.3 Reel - -

Cat 6 FTP Solid Conductors

C6FR 4 x 2 x 23AWG FTP PVC Grey 58 7.2 Reel - -

C6FHR 4 x 2 x 23AWG FTP LSHF Orange 58 7.2 Reel - -

Cat 6A F-FTP Individual & Overall Foil Screened Solid Conductors

C6GFFH 4 x 2 x 23AWG F-FTP LSHF Blue 58 8.0 Reel - -

Cat 7 S/FTP Individual Foil & Overall Braid Screened Solid Conductors

C7HR08 4 x 2 x 23AWG S/FTP LSHF Orange 60 7.4 Reel - -

C7HR08-Shotgun 2 x (2 x 4) x 23AWG S/FTP LSHF Orange 121 7.7 x 15.7 Reel - -

C6HB

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

26

Cat-5E UTP

C5EC 4 x 2 x 24AWG Cat-5E UTP PE - Weatherproof 40 5.6

C5ED 4 x 2 x 24AWG Cat-5E UTP PVC/PE - Duct Grade 67 8.6

C5EA 4 x 2 x 24AWG Cat-5E UTP PVC/PE/SWA/PE - Armoured 239 12.6

C525D 25 x 2 x 24AWG Cat-5 UTP PVC/PE - Duct Grade 278 17.0

C525A 25 x 2 x 24AWG Cat-5 UTP PVC/PE/SWA/PE - Armoured 598 21.6

Part No. Description Weight O/D mmkg/km

Cat-5E FTP

C5EFD 4 x 2 x 24AWG Cat-5E FTP PVC/PE - Duct Grade 68 8.8

C5EFA 4 x 2 x 24AWG Cat-5E FTP PVC/PE/SWA/PE - Armoured 275 12.2

Part No. Description Weight O/D mmkg/km

Cat-6 UTP

C6D 4 x 2 x 23AWG Cat-6 UTP PVC/PE - Duct Grade 86 9.9

C6A 4 x 2 x 23AWG Cat-6 UTP PVC/PE/SWA/PE - Armoured 309 14.2

Part No. Description Weight O/D mmkg/km

Cat-6 FTP

C6FD 4 x 2 x 23AWG Cat-6 FTP PVC/PE - Duct Grade 105 10.2

C6FA 4 x 2 x 23AWG Cat-6 FTP PVC/PE/SWA/PE - Armoured 315 14.5

Please note the armouring and oversheathing process can sometimes affect the performance of the cable. If your installation is likely to require optimum performance please check before installing to ensure it meetsyour requirement.

Category or structured wiring cable has always been on the delicate side, but treated carefully it does the job well. Now there is a cable available to cover the more demanding jobs.

Designed for fixed installations, the FSC range of duct grade or armoured Cat-5 & Cat-6 cables have heavy jackets ofpolyethylene to protect against moisture and give the cables extra strength.

The external version is ideal for running through ducts, up the side of a building or up masts. The armoured version is greatfor direct burial or vandal-plagued installations.

These cables are supplied on drums.

External Grade Structured Wiring

DATA External Grade Structured Wiring

C6D

C5EA

Duct Grade SWA

Part No. Description Weight O/D mmkg/km

C350H

With the spread of internet access over broadband, the need for high specification cables has grown. Cable to supportADSL data rates are increasingly being installed in offices, airports, education and commercial centres.

Cat-3 multipair is available in 25, 50, 100, 150 & 200 pair configurations and offers substantial benefits in terms of cost,space & weight with significantly reduced installation times when compared with multiple runs of standard 4 pair Cat-5 cable.

Multipair Cat-5 offers the same advantages as Cat-3 but at higher data rates.

Low Smoke Halogen Free versions are available where indicated with The insulation and sheath materials are replacedby those that do not emit halogens or toxic smoke.

Cat 3 Multipair & Cat 5 Multipair

Part No. Cable Jacket Weight O/DSize kg/km mm

C310 10 x 2 x 24AWG PVC 67 7.3

C310H 10 x 2 x 24AWG LSHF 67 7.3

C325 25 x 2 x 24AWG PVC 186 11.5

C325H 25 x 2 x 24AWG LSHF 186 11.5

C350 50 x 2 x 24AWG PVC 422 17.5

C350H 50 x 2 x 24AWG LSHF 422 17.5

C3100 100 x 2 x 24AWG PVC 710 23.5

C3100H 100 x 2 x 24AWG LSHF 710 23.5

C3150 150 x 2 x 24AWG PVC 880 28.0

C3150H 150 x 2 x 24AWG LSHF 880 28.0

C3200 200 x 2 x 24AWG PVC 1047 33.0

C3200H 200 x 2 x 24AWG LSHF 1047 33.0

Construction - Cat-3 Multipair

24(1) AWG solid plain copper conductor, colourcoded HDPE insulation, twisted into pairs andlaid up, polyester tape, PVC sheath.

Technical Information

Minimum Bend Radius: 10 x cable O/DConductor DCR: ≤ 9,38 Ohm/100mColour Code: Chart 5 page 166

Part No. Cable Jacket Weight O/D mm Size kg/km

C525 25 x 2 x 24AWG PVC 189 13.2

C525H 25 x 2 x 24AWG LSHF 189 13.2

C550 50 x 2 x 24AWG PVC 435 20.8

C550H 50 x 2 x 24AWG LSHF 435 20.8

Construction - Cat-5 Multipair

24(1) AWG solid plain copper conductor, colour codedPE insulation twisted into pairs. Laid up into a bundleand jacketed in PVC.

C525H

Low Smoke Halogen Free

Technical Information

Minimum Bend Radius: 10 x cable O/DConductor DCR: ≤ 9,38 Ohm/100mColour Code: Chart 5 page 166

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

27Cat 3 & Cat 5 Multipair ADSL DATA

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be suppliedon request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.

RG Coaxial

390059

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

75 Ohm

390006-C RG6 Type 75 1/1.02 Ali Foil & Braid FPE PVC 47 6.8

390006-CH RG6 Type LSHF 75 1/1.02 Ali Foil & Braid FPE LSHF 47 6.8

390006Q RG6 Quad 75 1/1.02 2 x Ali Foil & Braid FPE PVC 49 7.6

390011 RG11 A/U 75 7/0.40 PCWB PE PVC 149 10.3

390011H RG11 A/U LSHF 75 7/0.40 PCWB PE LSHF 149 10.3

390011A RG11 A/U SWA 75 7/0.40 PCWB PE LDPE 380 15.7

390059 RG59 B/U 75 1/0.58 PCWB PE PVC 60 6.1

390059L RG59 B/U LSF 75 1/0.58 PCWB PE LSF 60 6.1

390059H RG59 B/U LSHF 75 1/0.58 PCWB PE LSHF 60 6.1

390059D RG59 B/U Duct 75 1/0.58 PCWB PE LDPE 60 7.9

390059A RG59 B/U SWA 75 1/0.58 PCWB PE LDPE 60 10.3

390059MB RG59 Mini Black 75 1/0.41 TCWB PE PVC 16 3.6

390059MW RG59 Mini White 75 1/0.41 TCWB PE PVC 16 3.6

390059MBH RG59 Mini Black LSHF 75 1/0.41 TCWB PE LSHF 16 3.6

390059MWH RG59 Mini White LSHF 75 1/0.41 TCWB PE LSHF 16 3.6

390179 RG179 B/U 75 7/0.10 SPCWB PTFE FEP 15 2.5

390179Y RG179 PVC 75 1/0.35 TCWB PE PVC 12 2.6

390179H RG179 LSHF 75 1/0.35 TCWB PE LSHF 12 2.6

390179Y-S RG179 Stranded PVC 75 7/0.10 TCWB PE PVC 12 2.6

390179H-S RG179 Stranded LSHF 75 7/0.10 TCWB PE LSHF 12 2.6

390216 RG216 75 7/0.40 2 x PCWB PE PVC 169 10.8

390216H RG216 LSHF 75 7/0.40 2 x PCWB PE LSHF 169 10.8

390302 RG302 75 1/0.63 SPCWB PTFE FEP 4.7 5.3

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

78, 93 & 95 Ohm

390062 RG62 A/U 93 1/0.69 PCWB PESS PVC 60 6.2

390062H RG62 A/U LSHF 93 1/0.69 PCWB PESS PVC 60 6.2

390062A RG62 A/U SWA 93 1/0.69 PCWB PESS PVC 210 10.4

390108 RG108 Twin-Ax 78 2 x 7/0.32 TCWB PE PVC 48 5.9

390180 RG180 95 1/0.30 SPCWB PTFE FEP 29 3.7

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

28 COAXIAL RG Coaxial

Low Smoke Halogen Free Duct Grade SWA

Sheath, Insulation and Shield Codes

FEP Fluorinated Ethylene Propylene FPE Foamed Polyethylene LDPE Low Density Polyethylene PTFE PolyTetraFluoroEthylene PESS Polyethylene Semi SolidTCWB Tinned Copper Wire Braid

TFE TetraFluoroEthylenePEAS Polyethylene Air Spaced PVC Polyvinyl Chloride PEC Polyethylene Cellular GFB Glass Fibre BraidSPCWB Silver Plated Copper Wire Braid

Description BNC F-Type N-Type TNC Crimp

Crimp Crimp Twist-on Boots Crimp Crimp Crimp Crimp Crimp Crimp Tool

Plug Jack Plug Plug Jack Plug Jack Plug Jack

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

29RG Coaxial COAXIAL

Connectors

RG6 Type YB1BC1 YB1BC2 - - YB1FC1 YB1BC2 - - - - YTC2

RG6 Type LSHF YB1BC1 YB1BC2 - - YB1FC1 YB1BC2 - - - - YTC2

RG6 Quad YB1BC1 YB1BC2 - - YB1FC1 YB1BC2 - - - - YTC2

RG11 A/U YA2BC1 YA2BC2 - - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG11 A/U LSHF YA2BC1 YA2BC2 - - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG11 A/U SWA YA2BC1 YA2BC2 - - YA2FC1 YA2FC2 YA2NC1 YA2NC2 - - YTC3

RG59 B/U PVC YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U LSF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U LSHF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U Duct YA1BC1 YA1BC2 YA1BT1 - YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 B/U SWA YA1BC1 YA1BC2 YA1BT1 - YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG59 Mini Black YA8BC1 YA8BC2 - YA8BX700 - - - - - - YTC1

RG59 Mini White YA8BC1 YA8BC2 - YA8BX704 - - - - - - YTC1

RG59 Mini Black LSHF YA8BC1 YA8BC2 - YA8BX700 - - - - - - YTC1

RG59 Mini White LSHF YA8BC1 YA8BC2 - YA8BX704 - - - - - - YTC1

RG179 B/U YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG179 PVC YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG179 LSHF YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG179 Stranded PVC YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG179 Stranded LSHF YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG216 - - - - - - - - - - -

RG216 LSHF - - - - - - - - - - -

RG302 - - - - - - - - - - -

Connectors

RG62 A/U YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG62 A/U LSHF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG62 A/U SWA YA1BC1 YA1BC2 YA1BT1 - YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

RG108 Twin-Ax - - - - - - - - - - -

RG180 - - - - - - - - - - -

Description BNC F-Type N-Type TNC Crimp

Crimp Crimp Twist-on Boots Crimp Crimp Crimp Crimp Crimp Crimp Tool

Plug Jack Plug Plug Jack Plug Jack Plug Jack

To show the colour required please replace xx in the part number with:

00 Black 04 White

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be suppliedon request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.

RG Coaxial

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

50 Ohm RG Coaxial Cables

390008-C RG 8 Type 50 1/2.74 Ali Foil & TCWB PE PE 207 10.2

390008-CH RG 8 Type LSHF 50 1/2.74 Ali Foil & TCWB PE LSHF 207 10.2

390058 RG 58 C/U 50 19/0.18 TCWB PE PVC 46 5.1

390058H RG 58 C/U LSHF 50 19/0.18 TCWB PE LSHF 46 5.1

390058D RG 58 C/U Duct 50 19/0.18 TCWB PE LDPE 46 6.5

390058W RG 58 C/U White 50 19/0.18 TCWB PE PVC 46 5.1

390115 RG115 A/U 50 7/0.71 2 x SPCWB PTFE GFB 240 10.6

390142 RG142 B/U 50 1/0.91 2 x SPCWB PTFE FEP 74 4.9

390165 RG165 50 7/0.81 SPCWB PTFE GFB 180 10.4

390174 RG174 A/U 50 7/0.16 TCWB PE PVC 16 2.6

390174H RG174 A/U LSHF 50 7/0.16 TCWB PE LSHF 16 2.6

390178 RG178 B/U 50 7/0.10 SPCWB PTFE FEP 10 1.8

390179DB RG178 B/U Double braid 50 7/0.10 2 x SPCWB PTFE FEP 14 2.3

390188 RG188 50 7/0.17 SPCWB PTFE FEP 17 2.5

390196 RG196 50 7/0.10 SPCWB PTFE FEP 9 2.0

390212 RG212 50 1/1.41 2 x SPCWB PE PVC 123 8.4

390213 RG213 /U 50 7/0.75 PCWB PE PVC 166 10.3

390213H RG213 /U LSHF 50 7/0.75 PCWB PE LSHF 166 10.3

390214 RG214 /U 50 7/0.75 2 x SPCWB PE PVC 173 10.8

390214H RG214 /U LSHF 50 7/0.75 2 x SPCWB PE PVC 173 10.8

390218 RG218 50 1/4.95 PCWB PE PVC 658 22.0

390223 RG223 /U 50 1/0.90 2 x SPCWB PE PVC 49 5.4

390223H RG223 /U LSHF 50 1/0.90 2 x SPCWB PE LSHF 49 5.4

390225 RG225 50 7/0.79 2 x SPCWB PTFE GFB 268 10.9

390303 RG303 50 1/0.99 SPCWB PTFE FEP 47 5.3

390304 RG304 50 1/1.49 2 x SPCWB PTFE FEP 131 7.1

390316 RG316 50 7/0.17 SPCWB PTFE FEP 15 2.5

390316DB RG316 Double Braid 50 7/0.17 2 x SPCWB PTFE FEP 22 2.6

390393 RG393 50 7/0.80 2 x SPCWB PTFE FEP 245 10.0

390400 RG400 50 19/0.20 2 x SPCWB PTFE FEP 55 5.1

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

30 COAXIAL RG Coaxial

390059

Low Smoke Halogen Free Duct Grade

Sheath, Insulation and Shield Codes

FEP Fluorinated Ethylene Propylene FPE Foamed Polyethylene LDPE Low Density Polyethylene PTFE PolyTetraFluoroEthylene PESS Polyethylene Semi SolidTCWB Tinned Copper Wire Braid

TFE TetraFluoroEthylenePEAS Polyethylene Air Spaced PVC Polyvinyl Chloride PEC Polyethylene Cellular GFB Glass Fibre BraidSPCWB Silver Plated Copper Wire Braid

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

31RG Coaxial COAXIAL

Connectors

RG 8 Type YA9BC1 YA9BC2 - - - - YA9NC1 YA9NC2 - - 390L40-T1

RG 8 Type LSHF YA9BC1 YA9BC2 - - - - YA9NC1 YA9NC2 - - 390L40-T1

RG 58 C/U YA3BC1 YA3BC2 YA3BT1 YA3BX700 - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

RG 58 C/U LSHF YA3BC1 YA3BC2 YA3BT1 YA3BX700 - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

RG 58 C/U Duct YA3BC1 YA3BC2 YA3BT1 - - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

RG 58 C/U White YA3BC1 YA3BC2 YA3BT1 YA3BX700 - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

RG115 A/U - - - - - - - - - - -

RG142 B/U - - - - - - - - - - -

RG165 - - - - - - - - - - -

RG174 A/U YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG174 A/U LSHF YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

RG178 B/U YC6BC1 - - - - - - - - - -

RG178 B/U Double Braid YC6BC1 - - - - - - - - - -

RG188 - - - - - - - - - - -

RG196 - - - - - - - - - - -

RG212 - - - - - - - - - - -

RG213 /U YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

RG213 /U LSHF YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

RG214 /U YA5BC1 YA5BC2 - - - - YA5NC1 YA5NC2 - - YTC7

RG214 /U LSHF YA5BC1 YA5BC2 - - - - YA5NC1 YA5NC2 - - YTC7

RG218 - - - - - - - - - - -

RG223 /U YA6BC1 YA6BC2 - - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

RG223 /U LSHF YA6BC1 YA6BC2 - - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

RG225 - - - - - - - - - - -

RG303 - - - - - - - - - - -

RG304 - - - - - - - - - - -

RG316 YC4BC1 YC4BC2 - - - - - - YC4TC1 YC4TC2 YTC1

RG316 Double Braid YC4BC1 YC4BC2 - - - - - - YC4TC1 YC4TC2 YTC1

RG393 - - - - - - - - - - -

RG400 YA6BC1 YA6BC2 - - - - YA6NC1 YA6NC2 YA6TC1 YA6TC2 YTC1

Description BNC F-Type N-Type TNC Crimp

Crimp Crimp Twist-on Boots Crimp Crimp Crimp Crimp Crimp Crimp Tool

Plug Jack Plug Plug Jack Plug Jack Plug Jack

To show the colour required please replace xx in the part number with:

00 Black 04 White

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kVThere is an increasing demand for Broadcast standard video cables. The best known are the BBC specification PSF seriesfor which we stock a range of alternatives.

Broadcast Coaxial

Part No. Description Imp. Central Shield Dielectric Outer Colour Weight O/DOhms Cond. Sheath kg/km mm

Part No. Description Imp. Central Shield Dielectric Outer Colour Weight O/DOhms Cond. Sheath kg/km mm

Description BNC Crimp Tool

Crimp Plug Crimp Jack

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

32 COAXIAL Broadcast Coaxial

390PS13

390CC11

Broadcast Coax390PS12 PSF1/2 Style 75 1/0.80 2 x TCWB PE PVC Cream 93 7.5390PS12H PSF1/2 Style LSHF 75 1/0.80 2 x TCWB PE LSHF Cream 93 7.5390PS13 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Cream 74 6.5390PS1301 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Blue 74 6.5390PS1302 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Brown 74 6.5390PS1303 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Red 74 6.5390PS1306 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Violet 74 6.5390PS1310 PSF1/3 Style 75 1/0.60 2 x TCWB PE PVC Green 74 6.5390PS13H PSF1/3 Style LSHF 75 1/0.60 2 x TCWB PE LSHF Cream 74 6.5390PS13H01 PSF1/3 Style LSHF 75 1/0.60 2 x TCWB PE LSHF Blue 74 6.5390PS16 PSF1/6 Style 75 7/0.32 2 x PCWB PE PVC Black 44 5.2390PS17 PSF1/7 Style 75 1/0.42 TCWB PPC PVC Cream 14 2.9390PS19 PSF1/9 Style Triax 75 1/1.40 1 x TCWB + PEC PUR Red 160 11.2

1 x PCWB

Camera Cable Triax390CC08 Camera Cable 8 75 1/1.0 1 x TCWB + 1 x PCWB FPE PVC Red 106 8.5390CC08H Camera Cable 8 LSHF 75 1/1.0 1 x TCWB + 1 x PCWB FPE LSHF Red 106 8.5390CC08P Camera Cable 8 PUR 75 1/1.0 1 x TCWB + 1 x PCWB FPE PUR Red 106 8.5390CF08 Camera Cable 8 Flexible 75 7/0.35 1 x TCWB + 1 x PCWB FPE TPE Red 102 8.5390CC11 Camera Cable 11 75 1/1.40 1 x TCWB + 1 x PCWB FPE PVC Red 160 11.2390CC11H Camera Cable 11 LSHF 75 1/1.40 1 x TCWB + 1 x PCWB FPE LSHF Red 160 11.2390CC11P Camera Cable 11 PUR 75 1/1.40 1 x TCWB + 1 x PCWB FPE PUR Red 160 11.2390CF11 Camera Cable 11 Flexible 75 19/0.30 1 x TCWB + 1 x PCWB FPE TPE Red 158 11.2390CC14 Camera Cable 14 75 7/0.75 1 x TCWB + 1 x PCWB FPE PVC Red 268 14.0390CC14H Camera Cable 14 LSHF 75 7/0.75 1 x TCWB + 1 x PCWB FPE LSHF Red 268 14.0390CC14P Camera Cable 14 PUR 75 7/0.75 1 x TCWB + 1 x PCWB FPE PUR Red 268 14.0

Connectors

PSF1/2 Style - - -PSF1/2 Style LSHF - - -PSF1/3 Style YB5BC1 - YTC1PSF1/3 Style LSHF YB5BC1 - YTC1PSF1/6 Style - - -PSF1/7 Style YC9BC1 - -PSF1/9 Style Triax - - -

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

33Broadcast Coaxial COAXIAL

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire ResLSHF Power Cable – 0.6/1kV

The BT range of coaxial cables are to British Telecom specifications and are used for interconnecting equipment. British Telecom types BT2002 & BT2003 are used for digital telephone and data links. BT2002 is equivalent to ICL Part Number 80047293.

TZC coax is to a very similar standard to the BT3002 and is available in both single and multicore options from stock. Thecable is designed for Ericsson systems.

RA7000 has been developed as a higher performance version of BT2003 but with a smaller overall diameter. RA8000 is a high performance alternative to BT3002 with a much smaller overall diameter. Multicore versions are also available.

Telecom BT, TZC & RA Coaxial

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

Telecom BT Coaxial3902001 BT2001 75 7/0.20 PCWB PEC PVC 31 4.63902002 BT2002 75 7/0.20 2 x PCWB FPE PVC 51 5.13902002H BT2002 LSHF 75 7/0.20 2 x PCWB FPE LSHF 51 5.13902003 BT2003 75 1/0.61 2 x PCWB PE PVC 79 6.73902003H BT2003 LSHF 75 1/0.61 2 x PCWB PE LSHF 79 6.73903002 BT3002 75 1/0.31 2 x TCWB PE PVC 24 3.53903002H BT3002 LSHF 75 1/0.31 2 x TCWB PE LSHF 24 3.53903002/8 BT3002 8core 75 1/0.31 2 x TCWB PE PVC 214 16.03903002/16 BT3002 16core 75 1/0.31 2 x TCWB PE PVC 392 19.5

TZC CoaxialTZC75024 TZC 75 1/0.31 2 x TCWB PE PVC 24 3.5TZC7502408 TZC 8core 75 1/0.31 2 x TCWB PE PVC 219 14.5TZC7502416 TZC 16core 75 1/0.31 2 x TCWB PE PVC 394 19.1

RA Coaxial390RA7000 RA7000 75 1/0.60 Ali Foil & PCWB FPE LSHF 30 4.5390RA7000/8 RA7000 8core 75 1/0.60 Ali Foil & PCWB FPE LSHF 165 17.2390RA7000/16 RA7000 16core 75 1/0.60 Ali Foil & PCWB FPE LSHF 535 24.3390RA8000 RA8000 75 1/0.31 Ali Foil & TCWB FPE LSHF 13 2.8390RA8000/8 RA8000 8core 75 1/0.31 Ali Foil & TCWB FPE LSHF 124 11.0390RA8000/16 RA8000 16core 75 1/0.31 Ali Foil & TCWB FPE LSHF 228 14.8

Description BNC T43 Crimp Tool

Crimp Plug Crimp Jack Crimp Plug Crimp Jack

Telecom BT Coaxial ConnectorsBT2001 - - - - -BT2002 YB8BC1 YB8BC2 YB84C1 YB84C2 -BT2002 LSHF YB8BC1 YB8BC2 YB84C1 YB84C2 -BT2003 YB7BC1 YB7BC2 YB74C1 YB74C2 -BT2003 LSHF YB7BC1 YB7BC2 YB74C1 YB74C2 -BT3002 YB6BC1 YB6BC2 YB64C1 YB64C2 -BT3002 LSHF YB6BC1 YB6BC2 YB64C1 YB64C2 -BT3002 8core YB6BC1 YB6BC2 YB64C1 YB64C2 -BT3002 16core YB6BC1 YB6BC2 YB64C1 YB64C2 -

TZC Coaxial ConnectorsTZC YB6BC1 YB6BC2 YB64C1 YB64C2 -TZC 8core YB6BC1 YB6BC2 YB64C1 YB64C2 -TZC 16core YB6BC1 YB6BC2 YB64C1 YB64C2 -

RA Coaxial ConnectorsRA7000 YB9BC1 YB9BC2 YB94C1 YB94C2 -RA7000 8core YB9BC1 YB9BC2 YB94C1 YB94C2 -RA7000 16core YB9BC1 YB9BC2 YB94C1 YB94C2 -RA8000 - - - - -RA8000 8core - - - - -RA8000 16core - - - - -

Low Smoke Halogen Free

3902003

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

34 COAXIAL URM Coaxial

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The URM (Uni Radio-Metric) BS 2316 cables listed cover the majority of high frequency data and signal transmissionrequirements. Other types can be supplied on request, as can armoured, duct grade or alternative sheath colours.

URM 70 is widely used for security applications connecting CCTV equipment where the stranded conductor centre is lesslikely to break than the RG 59 type. This may be important where the camera pans and tilts. Other URM cables are availableto order.

URM Coaxial

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

391067

Low Smoke Halogen Free Duct Grade

URM Coaxial Cable

391043 URM 43 50 1/0.81 PCWB PE PVC 40 5.0

391054 URM 54 50 7/0.19 2 x PCWB PE PVC 118 8.3

391057 URM 57 75 1/1.15 PCWB PE PVC 158 10.3

391065 URM 65 75 1/1.15 PCWB PE PVC 158 10.3

391067 URM 67 50 7/0.77 PCWB PE PVC 162 10.3

391067H URM 67 LSHF 50 7/0.77 PCWB PE LSHF 162 10.3

391070 URM 70 75 7/0.19 PCWB PE PVC 59 5.8

391070W URM 70 White 75 7/0.19 PCWB PE PVC 59 5.8

391070L URM 70 LSF 75 7/0.19 PCWB PE LSF 59 5.8

391070H URM 70 LSHF 75 7/0.19 PCWB PE LSHF 59 5.8

391070D URM 70 Duct 75 7/0.19 PCWB PE LDPE 72 8.0

391074 URM 74 50 1/4.78 PCWB PE PVC 710 22.0

391076 URM 76 50 7/0.32 PCWB PE PVC 41 5.1

391091 URM 91 50 7/0.76 2 x PCWB PE PVC 170 11.0

391095 URM 95 50 1/0.46 PCWB PE Nylon 13 2.3

391106 URM 106 75 1/0.65 SPCWB PTFE FEP 45 5.3

391109 URM 109 50 7/0.18 SPCWB PTFE FEP 14 2.4

391110 URM 110 50 7/0.11 SPCWB PTFE FEP 12 1.8

391111 URM 111 75 7/0.10 SPCWB PTFE FEP 14 2.4

391112 URM 112 50 7/0.76 2 x SPCWB PE PVC 176 11.0

391115 URM 115 50 1/0.90 2 x PCWB PE PVC 85 7.2

391202 URM 202 75 7/0.25 PCWB PEC PVC 85 5.1

391070H

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

35URM Coaxial COAXIAL

Connectors

URM 43 YA3BC1 YA3BC2 YA3BT1 YA3BX700 - - YA3NC1 YA3NC1 YA3TC1 YA3TC2 YTC1

URM 54 - - - - - - - - - - -

URM 57 - - - - - - - - - - -

URM 65 - - - - - - - - - - -

URM 67 YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

URM 67 LSHF YA4BC1 YA4BC2 - - - - YA4NC1 YA4NC2 YA4TC1 YA4TC2 YTC3

URM 70 YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 White YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 LSF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 LSHF YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 70 Duct YA1BC1 YA1BC2 YA1BT1 - YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

URM 74 - - - - - - - - - - -

URM 76 - - - - - - - - - - -

URM 91 - - - - - - - - - - -

URM 95 - - - - - - - - - - -

URM 106 - - - - - - - - - - -

URM 109 YC4BC1 YC4BC2 - - - - - - YC4TC1 YC4TC2 YTC1

URM 110 - - - - - - - - - - -

URM 111 - - - - - - - - - - -

URM 112 - - - - - - - - - - -

URM 115 - - - - - - - - - - -

URM 202 - - - - - - - - - - -

Description BNC F-Type N-Type TNC Crimp

Crimp Crimp Twist-on Boots Crimp Crimp Crimp Crimp Crimp Crimp Tool

Plug Jack Plug Plug Jack Plug Jack Plug Jack

Sheath, Insulation and Shield Codes

FEP Fluorinated Ethylene Propylene FPE Foamed Polyethylene LDPE Low Density Polyethylene PTFE PolyTetraFluoroEthylene PESS Polyethylene Semi SolidTCWB Tinned Copper Wire Braid

TFE TetraFluoroEthylenePEAS Polyethylene Air Spaced PVC Polyvinyl Chloride PEC Polyethylene Cellular GFB Glass Fibre BraidSPCWB Silver Plated Copper Wire Braid

To show the colour required please replace xx in the part number with:

00 Black 04 White

Part No. Description Imp. Central Shield Dielectric Outer Weight O/DOhms Cond. Sheath kg/km mm

The TV range of cable television and video cables is used primarily to carry TV, Satellite and CCTV signals. These cablesare all 75 ohm and supplied in a variety of versions to suit different applications.

An optional heavy duty tough sheath to improve impact and moisture resistance makes the TV-DB range ideal for pullinginto ducts or for direct burial.

A version with an aluminium moisture barrier is also available. Cables can be armoured and sheathed with LDPE forquantities as low as 100 metres.

Digital Satellite & Cable TV Coaxial

Description BNC F-Type Crimp Tool

Crimp Plug Crimp Jack Right Angle Plug Crimp Plug Crimp Jack

392100FShotgun

Low Smoke Halogen Free Duct Grade

Satellite & Cable TV Coaxial392100 TV 100 75 1.00 Copper Foil & PCWB Airspaced PE PVC 49 6.6392100W TV 100 White 75 1.00 Copper Foil & PCWB Airspaced PE PVC 49 6.6392100HR TV 100 LSHF 75 1.00 Copper Foil & PCWB Airspaced PE LSHF 49 6.6392100F TV 100 75 1.00 Copper Foil & PCWB Foamed PE PVC 49 6.6392100F/5 TV 100 5core 75 1.00 Copper Foil & PCWB Foamed PE PVC 630 22.5392100WF TV 100 White 75 1.00 Copper Foil & PCWB Foamed PE PVC 49 6.6392100H TV 100 LSHF 75 1.00 Copper Foil & PCWB Foamed PE LSHF 49 6.6392100D TV 100 Duct 75 1.00 Copper Foil & PCWB Foamed PE LDPE 70 6.6392100F-Shotgun TV 100 Shotgun 75 1.00 Copper Foil & PCWB Foamed PE PVC 100 6.9 x 14.4

392125 TV 125 75 1.25 Copper Foil & PCWB Airspaced PE PE 69 8.0392125HR TV 125 LSHF 75 1.25 Copper Foil & PCWB Airspaced PE LSHF 69 8.0392125DB TV 125 RBS Sheath 75 1.25 Copper Foil & PCWB Airspaced PE PE/PP 90 9.5392125F TV 125 75 1.25 Copper Foil & PCWB Foamed PE PE 69 8.0392125F/5 TV 125 5core 75 1.25 Copper Foil & PCWB Foamed PE PE 80 25.5392125HR TV 125 LSHF 75 1.25 Copper Foil & PCWB Foamed PE LSHF 69 8.0392125WH TV 125 White LSHF 75 1.25 Copper Foil & PCWB Foamed PE LSHF 69 8.0392125DBF TV 125 Duct 75 1.25 Copper Foil & PCWB Foamed PE LDPE 90 9.5392167 TV 167 75 1.67 Copper Foil & PCWB Airspaced PE PE 115 10.1392167DB TV 167 Duct 75 1.67 Copper Foil & PCWB Airspaced PE LDPE 130 11.3392167F TV 167 75 1.67 Copper Foil & PCWB Foamed PE PE 115 10.1392167H TV 167 LSHF 75 1.67 Copper Foil & PCWB Foamed PE LSHF 115 10.1392233 TV 223 75 2.33 Copper Foil & PCWB Airspaced PE PE 135 12.7392233DB TV 223 Duct 75 2.33 Copper Foil & PCWB Airspaced PE LDPE 147 14.4392233F TV 233 75 2.33 Copper Foil & PCWB Foamed PE PE 135 12.7392233H TV 223 LSHF 75 2.33 Copper Foil & PCWB Foamed PE LSHF 135 12.7

Connectors392100 YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100W YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100HR YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100F YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100F/5 YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100WF YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100H YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100D YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392100F-Shotgun YB1BC1 YB1BC2 YB1BC8 YB1FC1 YB1FC2 YTC2392125 YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125HR YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125DB YC1BC1 YC1BC2 - YC1FC1 YC1FC2 YTC2392125F YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125F/5 YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125HR YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125WH YB2BC1 YB2BC2 - YB2FC1 YB2FC2 YTC2392125DBF YC1BC1 YC1BC2 - YC1BC1 YC1BC2 YTC2

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

36 COAXIAL Digital Satellite & Cable TV Coaxial

Part No. Description Construction Outer Weight O/D

Coax Power Cores Signal Cores Sheath kg/km mm

3900592/2 RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular PVC 185 12.0

3900592/2D RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular Duct LDPE 225 14.2

3900592/2H RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular LSHF LSHF 140 12.0

390059/2 RG59 B/U 2 x 0.75mm² - Shotgun PVC 92 5.9 x 12.0

390059/3 RG59 B/U 3 x 0.5mm² - Shotgun PVC 92 5.9 x 12.0

390059/2D RG59 B/U 2 x 0.75mm² - Circular Duct LDPE 110 6.1 x 12.0

390059-Shotgun 2 x RG59 B/U - - Shotgun PVC 102 6 x 12.4

390059H-Shotgun 2 x RG59 B/U - - Shotgun LSHF 102 6 x 12.4

391070/2 URM 70 2 x 0.75mm² - Shotgun PVC 98 6 x 12.0

390179Y3 3 x RG179 Unscreened Circular PVC 63 7.4

390179Y5F-S 5 x RG179 Overall Foil Screen Circular PVC 104 9.0

390179Y5FH-S 5 x RG179 Overall Foil Screen Circular LSHF 104 9.4

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

37Composite Coaxial COAXIAL

???????

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

To meet the increasing demands for camera cables containing a coax with power and control cores for Pan, Tilt, Zoom(PTZ) or audio we are now stocking various types. These can either be within one circular jacket for easy glanding or in ashotgun style with a web between the individual elements.

Please call to discuss your requirements and ask for details or samples of the current stock range.

Composite Coaxial Cables

Part No. Description Construction Outer Weight O/D

Coax Screen Sheath kg/km mm

Connectors

3900592/2 YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

3900592/2D YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

3900592/2H YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390059/2 YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390059/3 YA1BC1 YA1BC2 YA1BT2 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390059/2D YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390059-Shotgun YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390059H-Shotgun YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

391070/2 YA1BC1 YA1BC2 YA1BT1 YA1BX7xx YA1FC1 YA1FC2 YA1NC1 YA1NC2 YA1TC1 YA1TC2 YTC1

390179Y3 YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

390179Y5F-S YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

390179Y5FH-S YA7BC1 YA7BC2 - YA7BX7xx YA7FC1 - - - - - YTC1

Description BNC F-Type N-Type TNC Crimp

Crimp Crimp Twist-on Boots Crimp Crimp Crimp Crimp Crimp Crimp Tool

Plug Jack Plug Plug Jack Plug Jack Plug Jack

3900592/2

Low Smoke Halogen Free Duct Grade

To show the colour required please replace xx in the part number with:

00 Black 04 White

390L40H

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The AntennaxTM range of high performance, ultra low loss coaxial cables are designed forinterconnection of base stations, aerials and transceivers. Developed for microwave,satellite and telecommunication, Antennax coax cables are manufactured to guaranteehigh levels of performance across the broadband spectrum up to 5.8GHz.

Antennax 50 Ohm & 75 Ohm coaxial cables can be used as a direct alternative totraditional corrugated cables while offering similar high performance, greater flexibilityand faster termination with reduced risk of kinking.

The flexible braided design allows Antennax cables to be used throughout the installation, removing the need for jumpercables which are traditionally used to terminate corrugated coax cables.

75 Ohm versions are designed for use on wireless broadband video applications and specialised RF communications.

Antennax Feeder Coax

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

38 COAXIAL Antennax Feeder Cables

Low Smoke Halogen Free

Full technical datasheets and test reports are available for each cable showing attenuation, return loss and resistance

Part No. Cable Type Sheath Size Weight O/DMaterial mm kg/km mm

Antennax 50 Ohm

390L19 ANT-195 UV PE 1/0.94 30 4.95

390L19H ANT-195H LSHF 1/0.94 30 4.95

390L20 ANT-200 UV PE 1/1.12 30 4.95

390L20H ANT-200H LSHF 1/1.12 30 4.95

390L24 ANT-240 UV PE 1/1.42 50 6.1

390L24H ANT-240H LSHF 1/1.42 50 6.1

390L30 ANT-300 UV PE 1/1.78 80 7.6

390L30H ANT-300H LSHF 1/1.78 80 7.6

390L40 ANT-400 UV PE 1/2.74 100 10.3

390L40H ANT-400H LSHF 1/2.74 100 10.3

390L60 ANT-600 UV PE 1/3.61 200 12.7

390L60H ANT-600H LSHF 1/3.61 200 12.7

Antennax 75 Ohm

390L20H75 ANT-200H LSHF 1/0.64 31 5.0

390L24H75 ANT-240H LSHF 1/0.82 49 6.1

390L40H75 ANT-400H LSHF 1/1.65 101 10.3

390L60H75 ANT-600H LSHF 1/2.74 201 15.0

AntennaxAntennaxAntennax

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The AntennaxTM connectors are matched perfectly with the cables and minimise loss and provide easy termination eitherin the field or on the assembly bench. To ensure reliable weatherproof terminations a full range of tools, boots, shrouds,self amalgamating tapes and weatherproof PVC tape is also available.

It’s as important to us that your installation is reliable and trouble free as it is to you. If the connector type you need is notshown please ask us as we may well be able to supply it.

Antennax Feeder Coax

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

39Antennax Connectors COAXIAL

Please note ANT-600 connectors are clamp style

- - 390L19 390L19 390L19 - - - - - 390L19 390L19 390L24 390L24-CN1 -CN2 -CN3 -CS6 -CS7 -T1 S1

390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 390L20 - - - 390L24 390L24-CB1 -CB2 -CN1 -CN2 -CN3 -CT1 -CT2 -CT6 -CT7 -T1 -S1

390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24 390L24-CB1 -CB2 -CN1 -CN2 -CN3 -CT1 -CT2 -CT6 -CT7 -CS1 -CS6 -CS7 -T1 -S1

- - 390L30 390L30 - - - - - - - - 390L30 390L40-CN1 -CN2 -T1 S1

390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40 390L40-CB1 -CB1 -CN1 -CN2 -CN3 -CT1 -CT2 -CT6 -CT7 -CS1 -CS6 -CN7 -T1 -S1

- - 390L2075 390L2075 - 390L2075 390L2075 - - - - - - --CN1 -CN2 -CT1 -CT2

- - 390L2475 390L2475 - 390L2475 390L2475 - - - - - - --CN1 -CN2 -CT1 -CT2

- - 390L4075 390L4075 - 390L4075 390L4075 - - - - - - --CN1 -CN2 -CT1 -CT2

- - 390L6075 390L6075 - 390L6075 390L6075 - - - - - - --CN1 -CN2 -CT1 -CT2

- - 390L60 390L60 - - - 390L60 390L60 - - - 390L60 --CN1 -CN2 -CT6 -CT7 TS1

BNC Crimp N-Type Crimp TNC Crimp SMA Crimp Crimp Stripping

Male Female Male Female Right Angle Male Female Reverse Reverse Male Reverse ReverseTool Tool

Male Polarity Polarity Polarity PolarityMale Female Male Female

Connectors & Accessories

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

HD Media Composite Cables

Developed to carry HD Video, HDMI and high speed data, all the components in these cables have been developed with boththe present and future in mind.

By combining all elements within a single tough jacket these HD Media Composite Cables are far less likely to get kinked ordamaged during installation and allow general electrical contracting labour to pull in the carcass wiring.

The distinctive jacket colour of these cables also enables quick and easy identification.

The coaxial cables use a pure copper core with high braid coverage and bonded aluminium foil tape to give outstandingscreening performance.

The Cat-5 and Cat-6 cables carry signals at rates far in excess of the standard which allows for large file transfer betweendevices quickly and without corruption.

Additionally, with cables containing fibre or building control elements such as KNX, Crestron™, Mode™ or Lutron™ you canbe confident that the future is available now.

Cables are printed with the area and device numbers on the jacket to make marking or tagging during installation quick andsimple.

If you have a specific requirement that is not shown please ask as it may have been added since the catalogue was printed.It may also be possible to manufacture it to your requirement in small quantities and with a lead time of only a few weeks.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

40 HOME AUTOMATION HD Media Composite Cables

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Blue Cat 5E UTP1 x Red Cat 5E UTPPink Overall PVC Sheath with a White StripeOverall Diameter: 16.8mmWeight: 210kg/km

HA1

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Blue Cat 5E UTP1 x Red Cat 5E UTP1 x Grey building Control & Lighting CablePink Overall PVC Sheath with a Blue StripeOverall Diameter: 19.5mmWeight: 270kg/km

HA2

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Grey Cat 6 UTP1 x Violet Cat 6 UTPPink Overall PVC Sheath with a Black StripeOverall Diameter: 17.3mmWeight: 220kg/km

HA3

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Grey Cat 6 UTP1 x Violet Cat 6 UTP1 x Blue Cat 5E UTPPink Overall PVC Sheath with a Green StripeOverall Diameter: 18.7Weight: 250kg/km

HA4

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Grey Cat 6 UTP1 x Violet Cat 6 UTP1 x Green KNXPink Overall PVC Sheath with a Yellow StripeOverall Diameter: 18.4mmWeight: 260kg/km

HA7

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Grey Cat 6 UTP1 x Violet Cat 6 UTP1 x Blue Cat 5E UTPPink Overall LSHF Sheath with a Violet StripeOverall Diameter: 18.7Weight: 250kg/km

HA5

1 x Black Coaxial Cable1 x White Coaxial Cable1 x Grey Cat 6 UTP1 x Violet Cat 6 UTP1 x Orange FibrePink Overall PVC Sheath with a Brown StripeOverall Diameter: 16.6mmWeight: 235kg/km

HA6

HD Media Composite Cables

HA1

Conductor: Bare CopperDielectric: Foamed PE1st Screen: Bonded Aluminium Foil2nd Screen: Aluminium Wire Braid3rd Screen: Aluminium Foil4th Screen: Aluminium Wire BraidSheath: PVC

Overall Diameter: 7.54mmImpedance: 75 OhmNominal Capacitance: 52 pF/Ft ±3Velocity: 85%Return Loss: ≥ 20dB

Attenuation:55MHz 5.25 dB/100m450MHz 14.43 dB/100m1000MHz 21.49 dB/100m1800MHz 27.73 dB/100m3000MHz 37.50 dB/100m

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

41HD Media Composite Cables HOME AUTOMATION

Coaxial Cable

Conductor: Solid bare copper 0.570mmInsulation: PESheath: PVC

Complies to TIA/EIA 568B & ISO/IEC 11801

Overall diameter: 6.4mmImpedance: 100 Ohm ±15

Attenuation:1MHz 1.9 dB/100m4MHz 3.7 dB/100m10MHz 5.9 dB/100m16MHz 7.5 dB/100m20MHz 8.4 dB/100m31.25MHz 10.6 dB/100m62.5MHz 15.4 dB/100m100MHz 19.8 dB/100m155MHz 25.1 dB/100m200MHz 29.0 dB/100m250MHz 32.8 dB/100m

Cat 6 4Pair UTP PVC

Data Pair – White & blue

Conductor: 22(7)AWG tinned copperInsulation: PEScreen: Foil screened pair

with drain wire

Power Cores – Black & Red

Conductor: 18(7) AWG tinned copperInsulation: PVCSheath: PVC

Building Control Lighting Cable

No. of Fibres: 4

Fibre Size: 50/125µ

Other fibre combinations and sizes are available to order including 9/125 & 62.5/125, please contact us for more details.

Fibre

Conductor: Solid bare copper 0.51mmInsulation: PESheath: PVC

Complies to TIA/EIA 568B & ISO/IEC 11801

Overall diameter: 5.3mmImpedance: 100 Ohm ±15

Attenuation:1MHz 2.0 dB/100m4MHz 4.1 dB/100m10MHz 6.5 dB/100m16MHz 8.2 dB/100m20MHz 9.3 dB/100m31.25MHz 11.7 dB/100m62.5MHz 17.0 dB/100m100MHz 22.0 dB/100m

Cat 5E 4Pair UTP PVC

Technical Specifications for each element

HA5

Part No. No. of CSA Sheath Weight O/D ScreenedPairs mm2 Material kg/km mm

28100201 1 0.22 PUR 41 5.2 Yes28100202 2 0.22 PUR 60 8.0 Yes28100301 1 0.34 PUR 53 5.9 Yes28100302 2 0.34 PUR 64 6.5 Yes28100501 1 0.50 PUR 67 7.2 Yes28100502 2 0.50 PUR 75 9.0 Yes

1801POFOHPart No. Alt. to No. of AWG Sheath Weight O/D Screened Sheath

Belden Pairs Material kg/km mm Colour

A single pair 18AWG bi-directional digital Fieldbus cable for type A applications (31.25 KBits/sec)available in PVC, LSHF and SWA versions.

Databus® Foundation Fieldbus ISA/SP-50 Profibus PA Type A

CAN Bus (Control Area Network) is a non-addressable system which treats all devices as equal allowing forfast transmission of data. Due to its robust nature it has been widely adopted in the automotive industry.While all the types listed below are for high flexing automation applications, static versions can also besupplied.

CAN Bus Cables

1801PODF - 1 18(1) PVC 75 8.0 Yes Blue1801POFO 3076F 1 18(7) PVC 51 6.4 Yes Orange 1801POFOH LSHF 1 18(7) LSHF 51 6.4 Yes Orange 1801POFOA SWA 1 18(7) SWA/PE 246 9.6 Yes Black

Part No. Alt. to No. of AWG Sheath Weight O/D ScreenedBelden Pairs Material kg/km mm

A single pair 22AWG bi-directional digital Fieldbus cable for type B applications (31.25 KBits/sec)available in PVC, LSHF and SWA versions.

Databus® Foundation Fieldbus ISA/SP-50 Type B

2201POFO 3077F 1 22(7) PVC 29 4.9 Yes2201POFOH LSHF 1 22(7) LSHF 29 4.9 Yes2201POFOA SWA 1 22(7) SWA/PE 213 8.1 Yes

Part No. Alt. to No. of AWG Sheath Weight O/D ScreenedBelden Pairs Material kg/km mm

A high speed single pair 22AWG bi-directional digital Fieldbus cable for 1.0 & 2.5MBit/sec applicationsavailable in PVC, LSHF and SWA versions.

2201POFF 3078F 1 22(7) PVC 65 9.4 Yes2201POFFH LSHF 1 22(7) LSHF 65 9.4 Yes2201POFFA SWA 1 22(7) SWA/PE 287 12.6 Yes

Databus® Foundation Fieldbus ISA/SP-50 High Speed

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

42 BUS Industrial & Building Control

Low Smoke Halogen Free SWA

Part No. Alt. to Pairs x AWG Sheath Weight O/D Appl. ScreenedBelden Material kg/km mm

15ABDY 3082A P: 1Px15 D: 1Px18 PVC 174 12.2 Static Yes15ABDR 3083A P: 1Px15 D: 1Px18 CPE 174 12.1 Static Yes15ABDYA SWA P: 1Px15 D: 1Px18 SWA/PE 359 16.1 Static Yes15ABDY-HF Hi-FLEX P: 1Px15 D: 1Px18 PUR 209 12.1 Dynamic Yes

15ABDY

2003CODF-03

Part No. Alt. to No. of AWG Sheath Weight O/D ScreenedBelden Cores Material kg/km mm

Developed by Mitsubishi, CC-Link allows high speed communication between controllers and fielddevices. CC-Link is particularly popular in Asia and is used worldwide for time critical applications inconjunction with Mitsubishi Automation products. CC-Link is certified by CLPA and ensures productcompatibility.

CC-Link 1.10 FieldLink® Cables

2003CODF-03 YR47205 3 20 PVC 186 7.6 Yes2003CODFA SWA 3 20 SWA/PE 276 12.0 Yes

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

Designed for use on Allen Bradley DeviceNet systems, the ‘thick’ cable construction incorporates apower and data pair for backbone wiring. Several sheathing options are available for differentinstallation environments. These cables are also referred to as DeviceNet Trunk cables.

DeviceNet™ Thick Cables

Part No. Alt. to Pairs x AWG Sheath Weight O/D Appl. ScreenedBelden Material kg/km mm

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331) ‘Thin’ cables are designed to connect sensors, actuators and switches to the DeviceNet backbone(thick cable) on the Allen Bradley DeviceNet system. Similar in construction to the backbone cable,the ‘thin’ cable incorporates a power and data pair. Several sheathing options are available fordifferent installation environments. These cables are also referred to as DeviceNet Drop cables.

22ABDY 3084A P: 1Px22 D: 1Px24 PVC 65 7.0 Static Yes22ABDR 3085A P: 1Px22 D: 1Px24 CPE 68 7.1 Static Yes22ABDYA SWA P: 1Px22 D: 1Px24 SWA/PE 240 11.9 Static Yes22ABDY-HF Hi-FLEX P: 1Px22 D: 1Px24 PUR 64 7.0 Dynamic Yes

DeviceNet™ Thin Cables

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

43Industrial & Building Control BUS

SWA

2202POFGH

Part No. Alt. to No. of AWG Sheath Weight O/D ScreenedBelden Pairs Material kg/km mm

A range of single pair Bus cables is available for the LonWork’s system allowing convenient wiring viathe Free Topology concept. Due to the popularity of the system for building management applicationsin the public sector these cables are now stocked in Low Smoke Halogen Free versions. Duct grade andSWA options can also be manufactured for quantities as low as 100m.

Echelon LonWork System Cabling

1601PUY 8471 1 16(19) PVC 56 7.0 No1601PUYH LSHF 1 16(19) LSHF 56 7.0 No1601PUYD DUCT 1 16(19) LDPE 89 9.5 No1601PUYA SWA 1 16(19) PE 280 10.8 No

Part No. Alt. to No. of AWG Sheath Weight O/D ScreenedBelden Pairs Material kg/km mm

Designed for use on industrial and commercial Bus systems, these cables have become increasinglypopular on Building Management Systems (BMS). Available as one and two pair cables, screened andunscreened in Low Smoke Halogen Free, they provide the ideal low cost solution to Bus wiring.

Echelon LonWork System Cabling

2201PUGH 7701NH 1 22(1) LSHF 14 3.5 No2202PUGH 7702NH 2 22(1) LSHF 27 5.0 No2201POFGH 7703NH 1 22(1) LSHF 23 4.5 Yes2202POFGH 7704NH 2 22(1) LSHF 36 6.5 Yes

Part No. No. of AWG Sheath Weight O/D ScreenedPairs Material kg/km mm

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

Through the use of Category 5 style cables Industrial Ethernet provides a stable platform for linkingautomation systems and workstations. They are also suitable for interlinking different Bus protocolssuch as Profibus and Interbus. The use of finely stranded conductors and PUR sheathing compoundsmakes them ideal for frequent flexing and dynamic applications.

C52S-HF 2 24(19) PUR 65 6.1 YesC5S-HF 4 24(19) PUR 82 8.0 Yes

C5S-HF

Part No. Alt. to Pair Sheath O/D Application Screened Belden x mm2 Material mm

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331) The Interbus open ring topology allows integration of different field devices from control level down

to sensor switches over one system. Unlike traditional ring systems Interbus uses one cable to routedata back and forth to all devices. Each device or unit will amplify the signal before sending it on tothe next station. The data is transmitted over a 3 pair screened cable. For remote applications acomposite data and power cable is available.

2403POBP N/A 3P x 0.22 PVC 8.0 Static Yes2403POBP-HF 3102A 3P x 0.22 PUR 8.2 Dynamic Yes2403/3POBP-HF 3119A 3P x 0.22 + 3C 1.0 PUR 9.3 Dynamic with Yes

remote power

Industrial Ethernet Cables to IEEE 802.3

Interbus Cables

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

44 BUS Industrial & Building Control Bus Cables

Low Smoke Halogen Free Duct Grade SWA

Part No. No. of CSA Sheath Sheath Weight O/D ApplicationCores mm2 Material Colour kg/km mm

28100703 3 0.75 PVC Yellow 89 7.5 Light Flexing28100703H 3 0.75 LSHF Yellow 89 7.5 Light Flexing28100703-HF 3 0.75 PUR Yellow 89 7.5 Dynamic

All trademarks & tradenames are acknowledged.

Part No. Alt. to No. of AWG Sheath Sheath Weight O/D ScreenedBelden Pairs Material Colour kg/km mm

2401POHP+ YM29560 1 24(7) PVC Grey 63 6.7 Yes2401POHPH+ LSHF 1 24(7) LSHF Grey 63 6.7 Yes

28100703

2201PODF

Developed by Modicon, Modbus provides a master/slave communication between intelligentautomation devices. Based on Belden 9841, the Modbus cable has an increased jacket thickness toensure a correct termination into the Modbus connectors.

Modbus

Part No. Alt. to No. of Cond Sheath Sheath FastConn/ Weight O/D ApplicationBelden Pairs mm Material Colour Quickstrip kg/km mm

A range of single pair Bus cables for process and field communication in cell networks. The Profibusprotocol has been widely adopted for production and process automation applications providingtransmission rates up to 12Mbits/sec.

Profibus DP IEC 61158/EN 50170 SINEC L2

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

Safety Bus p® is an open Fieldbus system based on well established CAN Bus technology. Safety Busp® modules must be self monitoring, perform intelligent checks and react independently, thereforeremaining ‘safe’. Several versions of Safety Bus p® cables are available depending on the applicationand environmental conditions.

Pilz Safety Bus p®

2201PODF 3079A 1 0.64 PVC Violet Yes 62 8.0 Static

2201PODFHA SWA 1 0.64 LSHF Black No 188 11.5 Static

2201PODFHQ LSHF 1 0.64 LSHF Violet Yes 64 8.0 Static

2201PODFD DUCT 1 0.64 LDPE Black No 88 9.5 Wet/outdoor static

2201PODFHF Hi-FLEX 1 0.64 PUR Violet No 78 8.3 Dynamic

2201PODF7 3079E 1 0.64 PVC Violet No 65 8.0 European type static

2201PODFHT HiTEMP 1 0.64 FEP Violet No 64 7.2 High Temperature

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

45Industrial & Building Control Bus Cables BUS

Low Smoke Halogen Free Duct Grade SWA

18/22LCCH

Lutron are world leaders in lighting control systems for prestige residential properties as well asrestaurant, retail and commercial applications. In addition to the full range of genuine Lutron cableswe are also able to offer a high quality alternative to the GRX-CBL-346S for the GRAFIK Eye® 3000,4000, 5000 & 6000 systems manufactured using Low Smoke Halogen Free materials throughout.This enables installations in locations that prohibit the use of standard PVC types. Where the cableis run outside duct grade and armoured versions are also popular.

Lutron GRX-CBL-346S Grafik Eye Cables

Part No. Alternative to Sheath Colour O/D mm Weight kg/km

18/22LCCH Lutron GRX CBL-346S Blue 8.4 7218/22LCCHD Duct Grade Black 10.8 12318/22LCCHA SWA/PE Black 12.3 259

18/22ECCH

Part No. Alternative to Sheath Colour O/D mm Weight kg/km

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331) If you are installing a Mode Lighting Evolution system we offer an alternative to Belden 1502R.

The cable is electrically the same as the Lutron type above but uses a PVC jacket with a reducedoverall diameter for easy routing.

18/22ECC Belden 1502R Blue 6.4 6518/22ECCH LSHF Blue 6.4 6518/22ECCD Duct Grade Black 8.7 8918/22ECCA SWA/PE Black 10.5 223

Mode Lighting Cable

Technical Information

Voltage Rating: 300VTest Voltage: 1.5kVTemperature Rating: 0°C to +70°CSmoke Emission: IEC 61034-1 & 2Halogen Emission: IEC 60754-1 & 2

Cable Construction - Power Pair

Cable Construction - Data Pair

Conductors: 18(7)AWG tinned copper strandsInsulation: Polypropylene insulation –

1.97mm nominalColour code: Red & blackConductor resistance: 23 Ohm/km @ 20°C

Conductors: 22(7)AWG tinned copper strandsInsulation: Polypropylene insulation –

1.83mm nominalScreen: Aluminium/polyester screen and

24(7)AWG TCu drain wireColour code: Purple & whiteConductor resistance: 58 Ohm/km @ 20°CCapacitance: Core to core 45pF/m nominalImpedance: 120 Ohm nominal

Pair bundles laid up with polyester fillers, polyester tape, blue LSHF sheath.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

46 BUS System Specific Lighting Control Cables

Low Smoke Halogen Free Duct Grade SWA

31000502H

31000502A

With the increasing demand for ‘green’ buildings, Intelligent Building Technology systems cancontribute to significant energy savings over time.

The operation and control of heating, lighting and air condition among others can be aligned withexternal climate conditions or adjusted by an interface to pre-set levels.

FS Cables as member of the KNX association now offers KNX certified cable.

This features two twisted pairs of solid conductor with a foil screen and tinned copper drain wire ina green LSHF jacket. It has been tested and certified as being suitable for use in KNX systems and bearsthe KNX logo.

All KNX certified equipment has been tested and certified to meet this high standard and onlyequipment meeting this can carry the logo. This ensures the quality, reliability and guaranteedcompatibility of all KNX devices and equipment.

Part No. No. of Conductor Sheath Weight O/D KNXPairs mm Colour kg/km mm Reg No

KNX Cable

31000501QH 1 Quad 0.8 Green 57 6.2 N/A

31000502H 2 0.8 Green 62 6.8 150/8928/10

31000502H04 2 0.8 White 62 6.8 150/8928/10

31000502D 2 0.8 Black 95 9.2 150/8928/10

31000502A 2 0.8 Black 300 13.0 150/8928/10

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

47KNX BUS

Part No. No. of Conductor Sheath Sheath Length O/DPairs mm Colour Material mm

KNX Jumper Cables

31000501* 1 0.8 Grey PVC Bulk 5.9

31000501H 1 0.8 Green LSHF Bulk 5.2

31000501H190 1 0.8 Green LSHF 190mm 5.2

31000501H320 1 0.8 Green LSHF 320mm 5.2

Low Smoke Halogen Free Duct Grade SWA

* This jumper cable has the colour code of black & red.

FS Cables are the sole appointed supplier of the Simmtronic SPECS3 cables. Manufactured to very hightolerances using Low Smoke Halogen Free compounds throughout you can be confident the cable willfit the connectors first time and every time, resulting in a trouble free installation you can rely on. Be careful of imitations, only use the authentic Simmtronic Specs 3 cable printed with the Simmtronic logo.

For more information, please go to www.simmtronic.com or call 01992 456 869.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

48 BUS Simmtronic Specs 3

Plain copper wire strands, class 5 to BS6360, LSHF insulation - colour coded, LSHF sheath - White. 300/500V. -20°C to +90°C static.

C-Bus grey 2201POFPH-05 1 pair 22AWG screened cable for connection of SPX 310 area controllers and SPG.2gateway modules. Low Smoke Halogen Free throughout.

E-Bus white 1801PUYH-04 1 pair 18AWG unscreened cable for connection of intelligent remote devices to SPX 310area controllers and SPV.9 lighting control modules. Low Smoke Halogen Free throughout.

O-Bus/M-Bus pink 1801PUYH-07 1 pair 18AWG unscreened cable for communications from the SPX 310 area controllerand the SPV.9 lighting control modules. Low Smoke Halogen Free throughout.

E-Bus blue1801PUYH-01 1 pair 18AWG unscreened cable. Colour coded blue for fast identification this version of E-Bus provides emergency monitoring signals to the SPX 310 area controller or for identification ofspecific circuits spec 3 system. Low Smoke Halogen Free throughout.

T-Bus grey2202PTFRH 2 pair 22AWG individual and overall foil screen for dual connections of SPX310 areacontrollers and SPG.2 gateway modules. Low Smoke Halogen Free throughout.

SPV.9 Plug wiring A full range of Low Smoke Halogen Free flexible cables are available from stock for wiring three and six pin Ensto plugs allowing fast onsite installation. Stocked in either 1mm2 or1.5mm2.

Part No. Cores x mm2 Weight kg/km O/D mm

31801003 3 x 1.0 84 7.1

31801503 3 x 1.5 120 8.3

31801004 4 x 1.0 106 7.9

31801504 4 x 1.5 152 9.4

31801005 5 x 1.0 134 8.7

31801505 5 x 1.5 183 9.4

31801006 6 x 1.0 163 9.8

31801506 6 x 1.5 201 10.1

1801PUYH-01

1801PUYH-04

1801PUYH-07

Simmtronic Specs 3 & Lighting Multicores

Construction

TSM02020

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

49

Microphone cables come in many shapes and sizes. Super flexibility even at low temperatures is achieved through the useof a special insulation and highly flexible cotton fillers to maintain a constant capacitance and avoid noise when the cableflexes.

The spiral copper shield offers excellent screening whilst remaining flexible and providing mechanical support when thecable is under physical stress. The four core microphone cables are a star quad format.

Microphone Cables

Part No. Cores x Stranding Weight O/D Colourmm2 No. x mm kg/km mm

TSM02020 2 x 0.22 28 x 0.10 45 5.9 Black

TSM02040 4 x 0.22 28 x 0.10 55 6.5 Black

TSM03020 2 x 0.34 40 x 0.10 52 6.2 Black

TSM03040 4 x 0.34 40 x 0.10 64 6.8 Black

TSM05020 2 x 0.50 28 x 0.15 65 6.7 Black

TSM05040 4 x 0.50 28 x 0.15 75 7.2 Black

Part No. Cores x Stranding Screening Weight O/D Colourmm2 No. x mm kg/km mm

TSQ01010 1 x 4 x 0.15 19 x 0.10 Overall Braid 45 5.5 Black

TSQ02010 1 x 4 x 0.22 28 x 0.10 Overall Braid 60 6.5 Black

TSQ01040 4 x 4 x 0.15 19 x 0.10 Overall Braid 180 11.7 Black

TSQ01080 8 x 4 x 0.15 19 x 0.10 Overall Braid 280 14.9 Black

TSQ01012 12 x 4 x 0.15 19 x 0.10 Overall Braid 420 18.2 Black

TSQ01024 24 x 4 x 0.15 19 x 0.10 Overall Braid 780 25.0 Black

TSQ01010H 1 x 4 x 0.18 7 x 0.18 Overall Foil 50 4.7 Black

TSQ05010H 1 x 4 x 0.50 28 x 0.15 Overall Braid 60 6.5 Black

TSQ01040H 4 x 4 x 0.18 7 x 0.18 Overall Foil 150 11.4 Grey

TSQ01080H 8 x 4 x 0.18 7 x 0.18 Overall Foil 290 15.5 Grey

TSQ01012H 12 x 4 x 0.18 7 x 0.18 Overall Foil 425 19.3 Grey

Designed for longer runs where it is beneficial to run a number of signals down a single cable usingthe star quad format. These cables are highly flexible and robust enough for touring applications.

Multiple Star Quad Cables

AUDIO TruSound Microphone & Snake Cables

Multipair versions up to 30 pair are available with or without individual pair screens.

LSHF versions are also offered for use in sensitive areas or where local regulations permit.

Snake cables are shown on page 52.

Low Smoke Halogen Free

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

50 AUDIO TruSound Parallel Speaker Cable

TS804002

Designed for installations in pubs, clubs, gyms and public buildings as well as high end domesticinstallations, these parallel speaker cables provide easy termination due to the longitudinal coreidentification. The high number of pure copper strands and low resistance values enable the speakerto operate at optimum levels. The question when specifying is to check the purity of the copper as itis this which gives the lowest resistance figure. In TruSound speaker cables only pure electrolytic copperis used so it can be classed as OFC (Oxygen Free Copper).

Parallel Speaker Cables

Low profile speaker cable, suitable for laying under carpet, behind decorative moulding, along theceiling or under furniture. Suitable for fixed installations, this cable uses flexible PVC insulation makingit easily routable.

Flat Speaker Cable

Technical Information

Minimum Bend Radius: 5 x cable thickness

Part No. Size Stranding Weight O/D Cond. Cap Test Colourmm2 No. x mm kg/km mm Resistance pF/m Voltage

Ohm/km

TruSound Parallel Speaker Cable

TS800702 0.75 24 x 0.2 23 2.3 x 4.9 26.0 82 2kV Clear

TS801502 1.5 189 x 0.1 42 2.8 x 5.8 13.3 67 2kV Clear

TS802502 2.5 322 x 0.1 60 3.6 x 7.4 7.98 57 2kV Clear

TS804002 4.0 511 x 0.1 105 4.5 x 9.7 4.95 54 2kV Clear

TS806002 6.0 777 x 0.1 141 6.1 x 12.5 3.3 58 2kV Clear

TS810002 10.0 1260 x 0.1 252 7.0 x 15.0 1.91 62 2kV Clear

TruSound Low Smoke Halogen Free Parallel Speaker Cables

TS800702H 0.75 24 x 0.2 23 2.3 x 4.9 26.0 82 2kV White

TS801502H 1.5 189 x 0.1 42 2.8 x 5.8 13.3 67 2kV White

TS802502H 2.5 322 x 0.1 60 3.6 x 7.4 7.98 57 2kV White

TruSound Flat Speaker Cable

TSF01502 1.5 47 x 4 x 0.1 53 12.8 x 2.4 <13.3 White

TSF02502 2.5 80 x 4 x 0.1 60 14.6 x 2.6 <7.98 White

TSF04002 4.0 125 x 4 x 0.1 108 17.5 x 0.3 <4.95 White

Part No. Size Stranding Weight O/D Cond. Colourmm2 No. x mm kg/km mm Resistance

Ohm/Km

TS802502H

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

51TruSound Multicore Speaker Cable AUDIO

TSS02504

Designed for the professional these multicore speaker cables are extremely flexible due to the highrate of conductor twist and the insulation and jacket materials used. Ideal for winding on and offdrums when touring, they even remain flexible at low temperatures making rigging easier. They arealso ideal for large fixed installations where sound quality is important.

The range of conductor sizes enables long runs, or shorter runs with very low power loss.

Multicore Speaker Cable

Part No. Cores Stranding Weight O/D Cond. Test Colourx mm2 No. x mm kg/km mm Resistance Voltage

Ohm/km

TruSound Multicore Speaker Cables - Circular

TSS01502 2 x 1.5 30 x 0.20 75 7.0 <14 2kV Black

TSS01504 4 x 1.5 30 x 0.20 120 8.6 <14 2kV Black

TSS02502 2 x 2.5 50 x 0.25 90 7.5 <8 2kV Black

TSS02504 4 x 2.5 50 x 0.25 175 10.0 <8 2kV Black

TSS02508 8 x 2.5 50 x 0.25 330 14.0 <8 2kV Black

TSS04002 2 x 4.0 56 x 0.30 170 10.5 <5 2kV Black

TSS04004 4 x 4.0 56 x 0.30 265 13.0 <5 2kV Black

TSS04008 8 x 4.0 56 x 0.30 495 18.5 <5 2kV Black

TruSound Low Smoke Halogen Free Multicore Speaker Cables - Circular

TSS01502H 2 x 1.5 30 x 0.25 65 7.0 <14 2kV Black

TSS02502H 2 x 2.5 50 x 0.25 85 7.6 <8 2kV Black

TSS02504H 4 x 2.5 50 x 0.25 145 8.8 <8 2kV Black

TSS02508H 8 x 2.5 50 x 0.25 300 12.8 <8 2kV Black

TSS04002H 2 x 4.0 56 x 0.30 125 9.2 <5 2kV Black

TSS04004H 4 x 4.0 56 x 0.30 223 10.7 <5 2kV Black

TSS06002H 2 x 6.0 84 x 0.30 170 10.6 <3 2kV Black

Colour Code - Multicore Circular Speaker Cable:

01 Red

02 Blue

03 Black

04 White

Cables with 7 cores and above are number coded

Low Smoke Halogen Free

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

52 AUDIO TruSound Snake & DMX Cables

Snake cables are multicore audio cables usually linking a number of individual microphone cables oraudio feeds back to the mixing desk. Ideal for either fixed installation in permanent venues or ontemporary installations when the cables will be coiled up and stored after the show.

Snake Cables

Developed to ensure accurate transmission of digital AES/EBU audio signals and digital DMX controlsignals, these cables are used extensively in the entertainment industry. DMX is designed to workbetween 90Ω and 120Ω impedance. The level of shielding enables interference-free transmissioneven over long distances. The tough physical properties of the TruSound DMX cable make it one ofthe best products on the market.

DMX Cables

TSD02010

Part No. Pairs x Stranding Weight O/D ColourAWG No. x mm kg/km mm

TSSN0202 2 x 2 x 24 7 x 0.20 68 8.1 Black

TSSN0204 4 x 2 x 24 7 x 0.20 96 8.9 Black

TSSN0208 8 x 2 x 24 7 x 0.20 183 12.1 Black

TSSN0212 12 x 2 x 24 7 x 0.20 243 14.3 Black

TSSN0216 16 x 2 x 24 7 x 0.20 319 16.6 Black

TSSN0220 20 x 2 x 24 7 x 0.20 420 19.0 Black

TSSN0224 24 x 2 x 24 7 x 0.20 486 22.1 Black

TSSN0232 32 x 2 x 24 7 x 0.20 610 24.3 Black

TSSN0240 40 x 2 x 24 7 x 0.20 780 25.8 Black

TSSN0108Q 8 x 4 x 28 7 x 0.127 255 15.1 Black

Part No. Pairs x No. of Power Weight O/D Colourmm2 Cores x mm2 kg/km mm

TSD02010 1 x 2 x 0.22 - 50 6.0 Black

TSD02011 1 x 2 x 0.22 - 50 6.0 Blue

TSD02020 2 x 2 x 0.22 - 75 8.0 Black

TSD02150 1 x 2 x 0.22 3 x 1.5 175 11.6 Black

TSD02250 1 x 2 x 0.22 3 x 2.5 220 13.3 Black

TSD02270 2 x 2 x 0.22 3 x 2.5 380 18.3 Black

TSD021110 4 x 2 x 0.22 3 x 1.5 375 17.4 Black

TSD022110 4 x 2 x 0.22 3 x 2.5 460 19.3 Black

Please note some of the cables above are also available in Low Smoke Halogen Free.

TSSV0802

TSHMM02

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

53TruSound S-Video & HDMI Cables AUDIO

Construction

Fine tinned copper strands 28(7)AWG, foam

polyethylene insulation, aluminium foil, tinned

copper wire braid, PVC jacket. Two cables laid

together and circular black PVC sheathed.

Construction

Fine tinned copper strands 24(7)AWG, foam polyethylene insulation, cores twisted into pairs, each pair overallfoil screened in contact with tinned copper drain wire.

Fine tinned copper strands 24(7)AWG, polypropylene insulation.

Pairs and cores laid together, overall aluminium foil screen and overall tinned copper wire braid, PVC blacksheath.

Technical Information

Impedance: 75 Ohms +/- 3%Capacitance Core to Screen: 64 pF/mTemperature Range: -15°c to +70°C

Part No. Cores x Stranding Weight O/D Colourmm2 kg/km mm

TruSound S-Video

TSSV0802 2 x 0.08 7 x 0.12 70 7.5 Black

Part No. Description Weight O/D Colourkg/km mm

TruSound HDMI Cable & Plug

TSH00215 4 x 2 x 0.22mm² + 7 x 0.22mm² 130 10.0 Black

TSH00215-C1 HDMI plug with solder pins - - -

TruSound HDMI Pre-Made Leads

TSHMM02 HDMI 1.3 Male to HDMI 1.3 Male 2m

TSHMM03 HDMI 1.3 Male to HDMI 1.3 Male 3m

TSHMM05 HDMI 1.3 Male to HDMI 1.3 Male 5m

TSHMM10 HDMI 1.3 Male to HDMI 1.3 Male 10m

TSHMM15 HDMI 1.3 Male to HDMI 1.3 Male 15m

TSHMM20 HDMI 1.3 Male to HDMI 1.3 Male 20m

Part No. Description Length

The FSC range of high quality HDMI cables offer a quick and easy way to link devices throughout abuilding. Supplied either as bulk cables or more convenient to use, made up leads. You can be sureof a clear signal transmission.

HDMI Cable

S-Video Cable

Using two coaxial cables within one jacket this flexible S-Video cable is suitable for connection ofcameras, computers, audio, video & TV units. Each coax is screened with an aluminium foil and highcoverage tinned copper wire braid and coloured pvc jacket for easy identification.

Part No. Cores x mm² O/D Weight Gland Clipmm kg/km

38701002E 2 E 1.0 7.9 80 G251 RCH3438701003E 3 E 1.0 8.2 93 G251 RCH3438701004E 4 E 1.0 8.7 120 G251 RCH3738701502E 2 E 1.5 8.0 98 G251 RCH3738701503E 3 E 1.5 8.3 121 G251 RCH4338701504E 4 E 1.5 9.5 148 G252 RCH4738702502E 2 E 2.5 9.1 139 G252 RCH4738702503E 3 E 2.5 9.8 179 G252 RCH5138702504E 4 E 2.5 11.3 205 G252 RCH54

Standard pack size 100m or 500m. Other sizes are available to order. Also available in black and orange.

Fire Alarm Cable Standard & Enhanced

Construction

Solid plain copper conductor, flame retardant Low Smoke Halogen Free insulation. Metallic barrier tape withcopper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath.

Standard

Construction

Plain copper conductor, circuit integrity Low Smoke Halogen Free insulation, metallic barrier tape with copperearth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath.

Enhanced

Technical Information

Conductors: Copper wire to BS 6360 or IEC 60228Voltage Rating: 300/500VResistance to Fire Alone: IEC 60331: 3 hours at 750°C, BS 6387 Cat. C: 3 hours at 950°CResistance to Fire with Water: BS 6387 Cat. W: 15 mins at 650°C, plus 15 mins with water sprayResistance to Fire with Mechanical Shock: BS 6387 Cat. Z: 15 mins at 950°C with mechanical shockApprovals: BASEC, LPCB, BS7629: Part 1

BS 5839:1 2002 & EN 50200 Standard Grade

Part No. Cores x O/D Weightmm² mm kg/km

387E01002E 2 E 1.0 7.9 80

387E01003E 3 E 1.0 8.2 93

387E01004E 4 E 1.0 8.7 120

387E01502E 2 E 1.5 8.0 98

387E01503E 3 E 1.5 8.3 121

Part No. Cores x O/D Weight mm² mm kg/km

387E01504E 4 E 1.5 9.5 148

387E02502E 2 E 2.5 9.1 139

387E02503E 3 E 2.5 9.8 179

387E02504E 4 E 2.5 11.8 205

387E04002E 2 E 4.0 12.1 269

It is now recognised that in some buildings the continued functioning or circuit integrity of some cables is essential inproviding sufficient time for evacuation. The requirements divide ‘soft skin’ cables into 2 groups, Standard and Enhanced.

The ‘enhanced’ versions shown below are suitable for installation where evacuation may be delayed, for example inhospitals or high-rise buildings without sprinklers. The ‘enhanced’ group of cables offer a viable alternative to MICC (MineralInsulated Copper Clad) in many applications with the benefit of faster installation and easier routing.

Standards: BS 6387 C, W & Z BS 5839 - 1 2002 Enhanced GradeBS EN 50200 Classification PH 120BS 8434-2:2003 120min durationIEC 60332-3 Parts 1 & 3

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

54 FIRE & SECURITY Fire Alarm Cable

38701502E

387E01504E

387FTD5903

387FTD403

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

55Firetuf Data & Coaxial FIRE & SECURITY

FSC Draka Type Screen Sheath Weight O/DPart No. Part No. kg/km mm

FSC Draka Type Screen Sheath Weight O/DPart No. Part No. kg/km mm

387FTD5903 660096 75Ohm Coax 1/0.65mm Double braid LSHF Red 110 9.1YFTCBC1# - BNC Connector - - - -YTC10 - BNC Crimp tool - - - -

Due to the unique size of Firetuf Coax special BNC connectors have been designed as standard types do not fit.

Firetuf Data is a group of high performance fire survival data cables manufactured by Draka and designed to carry onfunctioning even in the event of a fire. This allows safe monitoring of evacuation routes without putting lives at risk.

The twisted pair cables provide high data transmission rates and have been developed to mimic Cat-5 cabling as closely aspossible. Increasingly popular with system integrators for BMS applications, the cables can be terminated using traditionalLAN Insulation Displacement Connectors (IDC) making them ideal for use in horizontal backbone wiring systems in officesand public buildings.

Where video is carried the coax performs in a similar way to RG59 which is widely used in the CCTV sector. This allowscontinued monitoring of fire exits and evacuation routes in the event of a fire. BNC connectors part no. YFTCBC1# areavailable to suit Firetuf Coax.

Where people and property come first the Draka Firetuf Data cable range provides the ideal solution.

Firetuf Data & Coaxial

Technical Information

Design: Generally to ISO/IEC 11801:95, EN 50173 95 and EN 50288-2-1. Suitable for standard insulation displacement connector L.A.N. sockets. RS-485 10Mb/s

Flame Retardant: IEC 60332-1-2, EN 60332-1-2, IEC 60332-3-24C, EN 60332-3-24C, BS 4066 part 3Smoke Emission: IEC 61034-2, EN61034-2, BS EN 50268-2Halogen Emission: IEC 60754-1, EN 50267-2-1, IEC 61034-2, EN 50267-2-2, LU 1-085 A2 - toxic fume emissionsFire Resistant: BS 5839 Clause 26.2E > 2hrs @ 950°C

BS 6387 > 3hrs @ 950°CIEC 60331-23 > 3hrs @ 750°CBS EN 50200 > 3hrs @ 950°CBS EN 50200:2000BS 8438-2:2003BS 8438-2 Class PH120 (120 minutes)BS 5839-1 2002 +A2 2008

London Underground Standard: LU 1-085-A2 fire safety performance of materials. Approved for use belowground without restriction.

387FTD103 910234 1 Pair 0.63mm [22(1)AWG] Foil & braid LSHF Red 48 6.8

387FTD203 910244 2 Pair 0.63mm [22(1)AWG] Foil & braid LSHF Red 97 8.1

387FTD403 910245 4 Pair 0.63mm [22(1)AWG] Foil & braid LSHF Red 122 10.4

Firetuf Coax

Firetuf Data

Construction

22(1)AWG solid plain copper conductor, PE/silicone rubber composite insulation,cores twisted into pairs, pairs laid up, woven glass tape, aluminium screen incontact with stranded tinned copper drain wire, tinned copper wire braid, LowSmoke Halogen Free sheath - red. Colour code : Chart 5 (Western Electric)

Construction

1/0.65mm solid plain copper conductor, PE/silicone rubber compositedielectric, woven glass tape, two plain copper wire braids, Low SmokeHalogen Free sheath – red

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Specifically designed for proprietary access control systems, these cables are widely used in publicbuildings including hospitals, government and local authority offices as well as commercial and retailorganisations where security and safety are important.

The Low Smoke Halogen Free versions ensure minimum risk in the event of fire to both property andpersonnel.

Access Control

Composite Access Control - Purple Pipe 3993P9CHP

Access Control

Construction

Pair 1: 1 twisted pair 20(7)AWG tinned copper strands, foam PE insulation, 20(7)AWG tinned copper drain wire, aluminium/polyester foil. Colour code: Black/green.

Pairs 2 & 3: 2 twisted pairs 22(7)AWG tinned copper strands, foam PE insulation, 22(7)AWG tinned copper drain wire, each individual pair aluminium/polyester foil screened. Pair colour code: Black/red & black/white.

Cores: 9 single cores 22(7)AWG tinned copper wire strands, solid polypropylene insulation. Colour code: Black, white, red, green, brown, blue, orange, yellow, purple. Overall Screen: aluminium/polyester foil, 22(7)AWG tinned copper drain wire.

Sheath: Low Smoke Halogen Free, purple.

Part No. Alt. to No. of AWG Screen Weight O/D ProtocolBelden Pairs type kg/km mm

Part No. Alt. to No. of AWG Screen Weight O/DBelden Pairs type kg/km mm

3993P9CHP - - - - 114 9.1

2202PIFRL 8723 2 22 Individual foils 32 4.2 Traditional security

2202PIFRH 8723NH 2 22 Individual foils 32 4.2 Traditional security

2203PIFRL 8777 3 22 Individual foils 32 7.0 Traditional security

2203PIFRH 8777NH 3 22 Individual foils 32 7.0 Traditional security

2402POHPL 9842 2 24 O/A foil & braid 95 8.6 RS-485

2402POHPH 9842NH 2 24 O/A foil & braid 95 8.6 RS-485

2802PODGH 8132NH 2 28 O/A foil & braid 45 5.6 RS-485

2803PODGH 8133NH 3 28 O/A foil & braid 52 6.8 RS-485

Access control and door release cables are also available from stock in PVC versions either in standard packsizes or cut to length from bulk drums.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

56 FIRE & SECURITY Access Control

3993P9CHP

2202PIFR

Low Smoke Halogen Free

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

57Composite Coaxial & Door Entry FIRE & SECURITY

3900592/2

DE12C

Low Smoke Halogen Free Duct Grade

Bus Wiring & Door Release

Composite Coaxial

Door Entry

Part No. Alt. to No. of AWG Screen Weight O/D ProtocolBelden Pairs type kg/km mm

1601PUYL 8471 1 16 Unscreened 56 7.0 Echelon

1601PUYH 8471NH 1 16 Unscreened 56 7.0 Echelon

Part No. Coax Power Signal Construction O/D ColourCores Cores mm

3900592/2 RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular 10.8 Black

3900592/2D RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular Duct 13.4 Black

3900592/2H RG59 B/U 2 x 1.5mm² 2 x 0.22mm² Circular LSHF 10.8 Black

390059/2 RG59 2 x 0.75mm² - Shotgun 12.7 x 6.2 Black

390059/2D RG59 2 x 0.75mm² - Circular Duct 10.3 Black

390059-Shotgun 2 x RG59 - - Shotgun 12.2 x 6.2 Black

390059H-Shotgun 2 x RG59 - - Shotgun LSHF 12.2 x 6.2 Black

391070/2 URM70 2 x 0.75mm² - Shotgun 10.2 x 5.8 White

Part No. Coax Power Signal Construction O/D ColourCores Cores mm

DE12C 7/0.15mm 75 Ω 1 x 1.5mm² + 6 x 1mm² 5 x 0.5mm² PVC 12.5 Grey

DE5C 7/0.15mm 75 Ω 2 x 1mm² 3 x 0.5mm² PVC 9.2 White

Other constructions are available on short lead-times please call us with your specific requirements.

To meet the increasing demands for camera cables containing a coax with power and control cores forPan, Tilt, Zoom (PTZ) or audio we are now stocking at a variety of options.

These can either be within one circular jacket for easy glanding or in a shotgun style with a webbetween the individual elements for branching off at termination points.

Designed to meet the need of the installer of proprietary door entry systems, door entry cables covervideo, voice and door release. Stocked on bulk drums, cutting to length is offered to reduce yourwastage and cut costs. Armoured and Duct grade versions are also available.

Composite Coaxial & Door Entry

Designed for inter-connecting sensors and control panels, alarm cables are widely used within the security industry.

Manufactured in white or black as standard, although other colours can be easily and quickly produced for quantities aslow as 300m, for example to identify a circuit or blend with a colour scheme.

Cables held in stock include standard PVC, Low Smoke Halogen Free, screened and duct grade versions.

Alarm Cables

Technical Information

Temperature Rating: 0°C to +70°C Max Working Voltage: 50VConductor Size: 0.22mm2 (24AWG) Max Current: 1 amp per core

Unscreened Alarm Screened Alarm

Part No. Cores Weight O/Dkg/km mm

PVC Unscreened Alarm Cable

39800204W 4 18 3.4

39800206W 6 25 4.0

39800208W 8 30 4.3

39800212W 12 37 5.5

Part No. Cores Weight O/Dkg/km mm

LSHF Unscreened Alarm Cable

39800204WH 4 18 3.4

39800206WH 6 25 4.0

39800208WH 8 30 4.3

39800212WH 12 42 5.7

Part No. Cores Weight O/Dkg/km mm

Duct Grade Unscreened Alarm Cable

39200206D 6 52 6.8

39200208D 8 56 7.1

39200212D 12 68 8.4

Part No. Cores Weight O/Dkg/km mm

PVC Foil Screened Alarm Cable

39900204W 4 24 3.7

39900206W 6 28 4.3

39900208W 8 34 4.6

39900212W 12 47 6.2

Part No. Cores Weight O/Dkg/km mm

LSHF Foil Screened Alarm Cable

39900204WH 4 24 3.7

39900206WH 6 28 4.3

39900208WH 8 34 4.6

Part No. Cores Weight O/Dkg/km mm

Duct Grade Screened Alarm Cable

39400206D 6 53 7.1

39400208D 8 58 7.6

39400212D 12 72 9.0

Core Colour Code4-core: Red, blue, yellow, black6-core: Red, blue, yellow, black, white, green8-core: Red, blue, yellow, black, white, green, orange*, brown12-core: Red, blue, yellow, black, white, green, orange, brown, grey, pink, violet, turquoise

*On duct grade cables core 7 is violet.

Brown or black PVC alarm cable also available.

Standard packing 100m, 200m & 500m spools.

Construction

PVC: Tinned copper wire strands, PVC insulation, PVC sheath

LSHF: Tinned copper wire strands, Low Smoke Halogen Free insulation, Low Smoke Halogen Free sheath (with or without aluminium foil screen)

Screened: Tinned copper wire strands, PVC insulation, aluminium foil screen with tinned copper drain wire, PVC sheath

Duct: Tinned copper wire strands, PVC insulation, PVC inner sheath, black LDPE outer sheath

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

58 FIRE & SECURITY Alarm Cables

Low Smoke Halogen Free Duct Grade

39800208W

39900208WH

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

59Outdoor Control FIRE & SECURITY

10001504D

The FSC range of duct grade YY cable is suitable to be either run through ducts or clipped to buildingsor other exposed areas when an armoured cable is not required. The cables are rated to 0.6/1kV andhave XLPE insulation, a PVC bedding and a UV stable black polyethylene sheath which also givesadditional mechanical strength and water resistance. The colour code is the conventional brown,blue, green/yellow (on three core) for simple wiring. Despite their toughness they remain remarkablyflexible.

The cable is stocked on bulk drums and can be cut to length to reduce your wastage and save time.If you don’t see the size you require please call us because we offer a cable over-sheathing service. Ifthese cables require added protection we can also armour them with MOQs as low as a hundredmetres. Please see page 152-153 for more details or call us with your specific requirements.

Despite their toughness they remain remarkably flexible. They can also be used as an alternative tothe old Delta Hi-Tuf cables.

Outdoor Control

Technical Information

Voltage Rating: 0.6/1kV Conductor Stranding: Stranded. IEC 60228 class 5 Temperature Rating: -30°c to +90°c Bending Radius: 10 x overall diameter

Construction

Plain copper wire conductors to IEC 60228class 5, XLPE colour coded insulation,bedding compound of PVC, UV resistantpolyethylene sheath.

For other cables suitable for outdoor applications please see page 60-61 for more details

10001002D 2 x 1.0 Blue, Brown 78 9.1

10001003D 3 x 1.0 Blue, Brown, Green/Yellow 98 9.2

10001004D 4 x 1.0 Brown, Black, Grey, Green/Yellow 121 9.6

10001005D 5 x 1.0 Blue, Brown, Black, Grey, Green/Yellow 149 10.7

10001502D 2 x 1.5 Blue, Brown 105 9.2

10001503D 3 x 1.5 Blue, Brown, Green/Yellow 156 10.5

10001504D 4 x 1.5 Brown, Black, Grey, Green/Yellow 181 11.4

10001505D 5 x 1.5 Blue, Brown, Black, Grey, Green/Yellow 201 12.3

10002502D 2 x 2.5 Blue, Brown 154 11.0

10002503D 3 x 2.5 Blue, Brown, Green/Yellow 183 11.0

10002504D 4 x 2.5 Brown, Black, Grey, Green/Yellow 241 13.1

10002505D 5 x 2.5 Blue, Brown, Black, Grey, Green/Yellow 304 14.2

Duct Grade

Part No. Cores x Colour Code Weight O/Dmm2 kg/km mm

2403POFYD

C5ED

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

60

Part No. Alternative Number of Weight O/D Colourto Belden Pairs & AWG kg/km mm

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

With the increased use of data and signal cables in security, BMS, access control and monitoringapplications the need for suitable cables to run outside or through ducts has grown. FS Cables offeran over-sheathing service for any stock product for quantities as low as 100m.

The products listed below are all stock items and have heavy additional black UV resistant polyethylenesheaths similar to those used on external telephone cables you see strung between poles or run thoughducts.

Outdoor Data & Coaxial

Outdoor Data Cables

1801POFPD 8760 1 x 2 x 18 48 7.6 Black

2202PIFRD 8723 2 x 2 x 22 50 6.2 Black

2203PIFRD 8777 3 x 2 x 22 96 8.6 Black

2401POFYD 9501 1 x 2 x 24 44 6.2 Black

2403POFYD 9503 3 x 2 x 24 66 8.1 Black

2404POFYD 9504 4 x 2 x 24 72 8.9 Black

2406POFYD 9506 6 x 2 x 24 93 9.6 Black

2402PIFFD 9729 2 x 2 x 24 79 10.2 Black

2402POHPD 9842 2 x 2 x 24 118 10.6 Black

FIRE & SECURITY Outdoor Data & Coaxial

Part No. Description Number of Weight O/D ColourPairs & AWG kg/km mm

Exterior Grade Structured Wiring

C5ED Cat 5E UTP Duct Grade 4 x 2 x 24 67 8.6 Black

C5EFD Cat 5E FTP Duct Grade 4 x 2 x 24 68 8.8 Black

C525D Cat 5 UTP Duct Grade 25 x 2 x 24 278 17.0 Black

C6D Cat 6 UTP Duct Grade 4 x 2 x 23 86 9.9 Black

C6FD Cat 6 FTP Duct Grade 4 x 2 x 23 105 10.2 Black

Duct Grade

Part No. Description Weight O/D Colourkg/km mm

Outdoor Coaxial Cables

390011D RG11 A/U Duct Grade 194 12.1 Black

390058D RG58 C/U Duct Grade 59 6.5 Black

390059D RG59 B/U Duct Grade 70 8.0 Black

391070D URM 70 Duct Grade 67 7.8 Black

392100D TV 100 Duct Grade 30 7.0 Black

392125D TV 125 Duct Grade 52 9.5 Black

392167D TV 167 Duct Grade 110 11.7 Black

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

61Armoured Data & Coaxial FIRE & SECURITY

Part No. Alternative Number of Weight O/D Colourto Belden Pairs & AWG kg/km mm

2202PIFRA 8723 2 x 2 x 22AWG 200 10.0 Black

2203PIFRA 8777 3 x 2 x 22AWG 330 13.3 Black

2402POHPA 9842 2 x 2 x 24AWG 431 16.3 Black

2402PIFFA 9729 2 x 2 x 24AWG 387 15.4 Black

Part No. Description Number of Weight O/D ColourPairs & AWG kg/km mm

Armoured Structured Wiring

C5EA Cat 5E UTP 4 x 2 x 24AWG 259 12.6 Black

C525A Cat 5E UTP 25 x 2 x 24AWG 540 20.2 Black

C5EFA Cat 5E FTP 4 x 2 x 24AWG 271 13.0 Black

C6A Cat 6 UTP 4 x 2 x 23AWG 354 14.3 Black

C6FA Cat 6 FTP 4 x 2 x 23AWG 386 15.1 Black

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

Where data or signal cables may be exposed to mechanical damage an additional protection ofgalvanised steel wire armour or SWA is ideal. Suitable for direct burial these cables are also popularin applications above ground where accidental or deliberate damage may occur.

CCTV installation in football stadiums, shopping centres and other public areas need to continuefunctioning despite the activities of trouble makers.

Equally important may be data or security cabling in car parks, warehouses and factories wherevehicle damage may severely compromise the operation of business.

Armoured Data & Coaxial

SWA

390059A

Armoured Coaxial Cables

390011A RG11 A/U 367 14.4 Black

390059A RG59 B/U 235 10.5 Black

390062A RG62 A/U 214 10.3 Black

Part No. Description Weight kg/km O/D mm Colour

390H124HLU

64904002

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

London Underground Approved Cables

Construction

Solid plain copper conductor, foamed PEdielectric, copper foil screen, plaincopper wire braid, LSHF inner sheath.

London Underground StandardE4156.1-A3 & E4156.2-A4Section 12 ApprovedLSHF Sheath Material to HD 624

Designed to meet London Underground (LU) specification for fire performance this collection of cables is also popular onoverground railways, other transport systems and other commercial applications where fire and smoke propagation arecritical factors.

Applications range from CCTV and radio communications to alarm and emergency evacuation circuits.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

62 LONDON UNDERGROUND LU Approved Cables

Part No. Description Imp. Central Dielectric Sheath Weight O/DOhms Cond. kg/km mm

390H124HLU H124 LSHF UV Resistant 75 1/1.00 FPE LSHF 53 7.0

Coaxial Cables

Triaxial Cables

Solid plain copper conductor, foamed PEdielectric, copper foil screen, plain copperwire braid, LSHF inner sheath.

London Underground Standard

E4156.1-A3 & E4156.2-A4Section 12 ApprovedLSHF Sheath Material to HD 624

Part No. Description Imp. Central Dielectric Sheath Weight O/DOhms Cond. kg/km mm

390H124HTLU H124 LSHF UV Resistant 75 1/1.00 FPE LSHF 99 8.8

Construction

Construction

24(1)AWG solid plain copper conductor, polyolefin insulation, tinned copper drain wire in contact with overallaluminium foil screen, flame retardant LSHF grey sheath.

This cable meets the London Underground Code of Practice for Fire Safety of Materials used in the Underground.

Part No. Description Weight O/D Packed Colourkg/km mm

C5EFHRLU Cat 5E FTP LSHF 40 6.5 On reels Grey

Cat 5E FTP LSZH

Construction

Class 2 plain copper conductor, singleor double layer of LSHF insulation.

Part No. Size mm2 Insulation Weight O/DLayer kg/km mm

649010xx 1.0 Double 35 4.7649015xx 1.5 Double 40 2.0649025xx 2.5 Double 55 5.3649040xx 4.0 Double 75 6.0649060xx 6.0 Double 100 6.6649100xx 10 Double 150 7.8649160xx 16 Single 190 7.6649250xx 25 Single 300 9.6649350xx 35 Single 390 10.8

*please see page 91 for colour chart

Single Core LSHF

Technical InformationTemperature Rating: 90°CVoltage Rating: 450/750V ACFire Test & Smoke Emission: 1.0-10mm² to LUL 1-085

16 – 35mm² to LUL 2-01001-002Toxicity: To LUL 1-085

387FTD403

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

63LU Approved Cables LONDON UNDERGROUND

Construction

Solid plain copper conductor, silicone rubber, metallicbarrier, tinned copper earth conductor, Low SmokeHalogen Free sheath.

Part No. Cores x mm2 Colour Weight O/Dkg/km mm

38701502FTER 2 x 1.5 Red 100 7.7

38701502FTEW 2 x 1.5 White 100 7.7

38701504FTER 4 x 1.5 Red 145 9.2

38701504FTEW 4 x 1.5 White 145 9.2

38702502FTER 2 x 2.5 Red 150 8.9

38702502FTEW 2 x 2.5 White 150 8.9

38702504FTER 4 x 2.5 Red 220 10.9

38702504FTEW 4 x 2.5 White 220 10.9

Fire Alarm Cable - Standard

Standards

BS5839-1:2002 Clause 26.2d standardBS EN 50200 PH30, PH 60 Annexe E.BS 6387 C, W & ZIEC 60331-2, IEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268

Construction

Solid plain copper conductor, enhanced siliconerubber, glass tape, tinned copper earth conductor,metallic barrier, enhanced Low Smoke HalogenFree sheath.

Part No. Cores x mm2 Colour Weight O/Dkg/km mm

387E01502FTER 2 x 1.5 Red 130 8.6387E01502FTEW 2 x 1.5 White 130 8.6387E01504FTER 4 x 1.5 Red 170 10.1387E01504FTEW 4 x 1.5 White 170 10.1387E02502FTER 2 x 2.5 Red 175 9.9387E02502FTEW 2 x 2.5 White 175 9.9387E02504FTER 4 x 2.5 Red 250 11.9387E02504FTEW 4 x 2.5 White 250 11.9

Fire Alarm Cable - Enhanced

Standards

BS5839-1:2002 Clause 26.2e enhancedBS8434-2:2003BS EN 50200 PH120BS 6387 C, W & ZIEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268

For full technical details please see page 55

FSC Part No. Draka Type Screen Sheath Weight O/DPart No. kg/km mm

387FTD103 910234 1 Pair 0.63mm Foil & Braid LSHF red 48 6.8[22(1)AWG]

387FTD203 910244 2 Pair 0.63mm Foil & Braid LSHF red 97 8.1[22(1)AWG]

387FTD403 910245 4 Pair 0.63mm Foil & Braid LSHF red 122 10.4387FTD5903 660096 75ohm coax Double braid LSHF red 110 9.1

1/0.65mm

Firetuf Data & Coax

387E01504FTER

Fire resistant screened power cables provide EMI screening and circuit integrity in the event of a fire. They are ideal forapplications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to aminimum during normal operation and services must be maintained for evacuation during a fire situation. The cables meetIEC 60331 and are fire resistant for 3 hours at 750°C.

E30 System integrity cables to DIN 4102 part 12 are also available on request.

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Manufactured to British Telecom Specification CW1308, this cable is used for internal connection of telephone systems andother communications equipment.

Insulated and sheathed in PVC, these cables offer an extremely cost effective general signal cable for fixed installation.Standard sheath colour is white although some sizes are available in black or grey.

A full range of European specification telephone cables is also available on short lead times, please call us with your requirements.

CW1308 PVC Internal

Construction

Solid copper conductor, colour coded PVC insulation,

twisted in pairs, rip cord, PVC sheath.

Technical Information

Conductor Diameter: 0.5mm Earth 1.38mm

Max. Conductor Resistance: 97.8 Ohm/km 12.4 Ohm/km

Max. Capacitance Unbalanced: 500pF/km

Temperature Rating: Working 0°C to +70°C

Min. Bend Radius Fixed: 8 x cable diameter

Other pair combinations or larger numbers of pairs and alternative conductorsizes are available on request.

Cables ending with E include a 1.38mm Earth core.

Colour codes to BT Standards, see page 166-167.

Part No. No. of Pairs Weight kg/km O/D mm

30802 2 21 4.5

30803 3 28 5.0

30804 4 34 5.8

30806 6 44 6.8

30810 10 67 8.3

30810E 10+E 85 8.6

30815 15 115 9.8

30820 20 150 10.7

30820E 20+E 183 12.0

30825 25 184 11.4

30825E 25+E 210 12.0

30830 30 226 12.2

30830E 30+E 262 12.9

30840E 40+E 371 15.0

30850E 50+E 427 17.0

30880E 80+E 610 20.2

308100E 100+E 708 27.0

308160E 160+E 1059 30.3

308200E 200+E 1393 33.1

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

64 TELEPHONE CW1308 PVC

30810E

When you need a LSHF internal telephone cable but don’t want to go to the expense of CW1600 this range is ideal.

Manufactured generally in accordance with BT CW1308 specification both the insulation and sheath materials have beenchanged to ones that don’t emit poisonous halogens in the event of a fire. These cables are not to be confused with thecheaper, PVC insulated, modified PVC jacketed LSF versions that have appeared on the market in the last few years.

CW1308 LSHF Internal

Construction

Solid copper conductor, colour coded Low Smoke

Halogen Free insulation, twisted into pairs, rip cord,

Low Smoke Halogen Free jacket, white. Earth core

in cables with 10 pairs or more.

Technical Information

Conductor Diameter: 0.5mm Earth 1.38mm

Max. Conductor Resistance: 97.8 Ohm/km 12.4 Ohm/km

Max. Capacitance Unbalanced: 500pF/km

Temperature Rating: Working 0°C to +70°C

Min. Bend Radius Fixed: 8 x cable diameter

30850EHPart No. No. of Pairs Weight kg/km O/D mm

30802H 2 22 4.5

30803H 3 31 5.0

30804H 4 34 5.8

30806H 6 50 6.8

30810EH 10+E 102 8.6

30820EH 20+E 161 12.0

30850EH 50+E 352 17.0

308100EH 100+E 687 27.0

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

65CW1308 LSHF TELEPHONE

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

This cable is similar in design and application to CW1308 but with the addition of an aluminium foil screen and LowSmoke Halogen Free cores and sheath.

Used for the internal wiring of buildings where the need to protect people and equipment from smoke and fumes is paramount. CW1600 has the added advantage of an aluminium/polyester foil screen and drain wire.

A fire barrier tape is included on cable with more than 6 pairs. A rip cord is located directly under the jacket to makestripping the outer sheath easier.

CW1600 LSHF Limited Fire Hazard

Construction

Solid copper conductor, colour coded Low Smoke Halogen Free

insulation. Twisted into pairs, screened with an aluminium /

polyester tape in contact with solid copper drain wire, fire barrier

tape on cables with more than 6 pairs, Low Smoke Halogen Free

sheath.

Cables ending with E include a 1.38mm Earth core.

Colour codes to BT Standards, see page 166-167.

All sizes are normally available from stock.

Armoured versions can be produced to order for quantities as low as 100m.

Technical Information

Conductor Diameter: 0.5mm Earth 1.38mm

Max. Conductor Resistance: 97.8 Ohm/km 12.4 Ohm/km

Max. Capacitance Unbalanced: 500pF/km

Temperature Rating: Working 0°C to +70°C

Minimum Bending Radius: 8 x cable diameter

Oxygen Index: 35%

HCl Emissions to: BT M234

Part No. No. of Pairs Weight kg/km O/D mm

60003 3 35 6.0

60004 4 39 6.4

60006 6 66 6.8

60010E 10+E 102 8.6

60020E 20+E 167 12.0

60040E 40+E 295 15.0

60050E 50+E 358 20.0

600100E 100+E 692 26.0

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

66 TELEPHONE CW1600 LSHF

60010E

CW1044 is primarily intended to provide a connection to earth for internal telephone systems. It features a single core plain annealed copper conductor which is solid in 1.5mm2 and stranded inall other sizes. 16mm2 and above is stocked in Low Smoke Halogen Free versions only. The insulationis cream with black printing ‘Telecom Functional Earth’.

CW1044 Functional Earth

Standard packing on Drop Wire is 350m reels.

The FSC range of self supporting aerial cables is designed for use in local area networks to link betweenpole and building or two buildings. The high tensile steel strainer wires are incorporated within thecable. A black polyethylene sheath, which is UV stable offers excellent weather resistance.

2 pair Ref: CW1411 4 pair Ref: CW1417

CW1411 & CW1417 BT Drop Wire

Part No. BT No. of Pairs Conductor Weight Nominal O/D mmRef Dia. mm kg/km

37802 10B 2 0.5 32 5.3

37804 14 (55m) 4 0.5 35 5.6

Part No. Size Stranding Weight kg/km Nominal O/D mm mm²

044015 1.5 1/1.38 24 3.3

044025 2.5 7/0.67 38 3.9

04404 4.0 7/0.85 57 4.6

04406 6.0 7/1.04 87 5.4

04410 10 7/1.35 110 6.1

04416H 16 7/1.70 172 7.1

04425H 25 7/2.14 285 8.9

04435H 35 7/2.52 380 10.1

04450H 50 19/1.78 510 11.8

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

67Functional Earth & Drop Wire TELEPHONE

04416H

37804

Low Smoke Halogen Free

Solid 0.9mm

12800901Q 2 (Quad) 0.9 72 7.2

12800905 5 0.9 160 11.5

12800910 10 0.9 261 14.0

12800920 20 0.9 452 18.0

12800950 50 0.9 1076 26.5

128009100 100 0.9 2033 36.0

CW1128 external telephone cables are suitable for installation outdoors where an armoured cable is not necessary. Theyoffer a lightweight, compact, tough solution for cables that will have to endure a variety of weather conditions, from rainand snow to bright sunlight.

CW1128 is ideal for clipping around the outside of buildings or running through ducting.

The outer sheath is made from tough, durable polyethylene which is also UV and sunlight resistant. The pairs are beddedin petroleum jelly to protect against the ingress of moisture.

CW1128 External

Construction

Solid plain copper conductor, colour coded polyethylene

insulation, petroleum jelly filled, separator tape and a black

polyethylene sheath.

Technical Information

Conductor Diameter: 0.5mm 0.9mm

Max. Conductor Resistance: 91 Ohm/km 28 Ohm/km

Insulation Resistance: 1500 Mohm/km 1500 Mohm/km

Capacitance Unbalanced: >3pair 275pF/m 275pF/m

Colour Code: see page 167 To CW1128 To CW1128

Part No. No. of Conductor Weight kg/km O/D mm Pairs Dia. mm

Solid 0.5mm

12800502 2 (Quad) 0.5 50 5.9

12800503 3 0.5 58 6.6

12800505 5 0.5 76 8.0

12800510 10 0.5 113 9.5

12800520 20 0.5 184 12.0

12800530 30 0.5 249 13.0

12800550 50 0.5 381 16.5

128005100 100 0.5 710 22.0

Part No. No. of Conductor Weight kg/km O/D mm Pairs Dia. mm

Aluminium screened/moisture barrier versions of this cable are also available in the style of CW1179with some sizes from stock. Please call to check availability.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

68 TELEPHONE CW1128

12800520

Duct Grade

Part No. No. of Conductor Weight kg/km O/D mm Pairs Dia. mm

Part No. No. of Conductor Weight kg/km O/D mm Pairs Dia. mm

Solid 0.9mm

19800901Q 2 (Quad) 0.9 320 12.8

19800905 5 0.9 496 13.9

19800910 10 0.9 738 17.4

19800920 20 0.9 1257 23.6

19800950 50 0.9 2310 32.3

198009100 100 0.9 3487 40.6

Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please callto check availability.

CW1128/1198 type telephone cables are used for external connection of telephone systems and other communicationsequipment where the added protection of steel wire armouring is needed. This cable is ideally suited for direct burial.

The outer sheath is made from tough, durable polyethylene or external grade PVC which is UV and sunlight resistant. The cores are bedded in petroleum jelly to protect against the ingress of moisture.

CW1128/1198 Armoured

Construction

Solid plain copper conductor, colour coded

polyethylene insulation, petroleum jelly filled,

separator tape, polyethylene bedding, galvanised

steel wire armour and a black or grey polyethylene or

external grade PVC sheath.

Technical Information

Conductor Diameter: 0.5mm 0.9mm

Max. Conductor Resistance: 91 Ohm/km 28 Ohm/km

Insulation Resistance: 1500 Mohm/km 1500 Mohm/km

Capacitance Unbalanced: >3pair 275pF/m 275pF/m

Colour Code: see page 167 To CW1128 To CW1128

19800520Solid 0.5mm

19800501Q 2 (Quad) 0.5 187 10.1

19800505 5 0.5 218 11.0

19800510 10 0.5 285 12.2

19800520 20 0.5 378 14.5

19800530 30 0.5 621 16.2

19800550 50 0.5 896 20.4

198005100 100 0.5 1368 26.2

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

69CW1128/1198 TELEPHONE

SWA

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

70 TELEPHONE J-Y(St)Y: PVC Screened

Originally developed for use within offices and factories J-Y(St)Y meets the needs of the German telecom installers andincreasingly their European counterparts. The larger conductor sizes result in lower losses than the traditional BritishCW1308. The foil screen also reduces interference either radiating from or picked up by the cable. Other applicationsinclude security, agriculture, intercom and bus systems.

J-Y(St)Y: PVC Screened Telephone Cable

Construction

Solid copper wire conductors to IEC 60228 class 1, PVC

insulation, overall foil screen in contact with solid copper

drain wire, PVC sheath – grey.

Technical Information

Voltage Rating: 300V

Conductor Stranding: Solid IEC 60228 class 1

Temperature Rating: Static -30°C to +70°C

Flexing -5°C to +50°C

Bending Radius: Fixed 7.5 x overall diameter

Flame Retardant: VDE 0472 test B,

IEC 60332-1-2, EN 50265-2-1

Manufactured To: VDE 0815

J-Y(St)Y can be also be supplied with a red outer jacket for identifying fire

alarm systems that do not need to meet British building regulations,

please put ‘03’ at the end of the part number to specify this cable.

Also available unscreened as J-YY

Core Identification

Colour code according to DIN VDE 0815.

Part No. Pairs x Weight O/Dmm kg/km mm

31000602 2 x 2 x 0.6 45 5.0

31000603 3 x 2 x 0.6 55 6.4

31000604 4 x 2 x 0.6 65 6.6

31000605 5 x 2 x 0.6 75 7.3

31000606 6 x 2 x 0.6 85 7.5

31000608 8 x 2 x 0.6 95 8.0

31000610 10 x 2 x 0.6 115 10.1

31000612 12 x 2 x 0.6 130 10.4

31000616 16 x 2 x 0.6 155 11.0

31000620 20 x 2 x 0.6 200 12.1

31000624 24 x 2 x 0.6 225 13.2

31000630 30 x 2 x 0.6 285 14.0

31000640 40 x 2 x 0.6 355 15.1

31000650 50 x 2 x 0.6 440 17.3

31000660 60 x 2 x 0.6 510 19.2

31000680 80 x 2 x 0.6 650 21.3

310006100 100 x 2 x 0.6 850 24.0

Part No. Pairs x Weight O/Dmm kg/km mm

31000802 2 x 2 x 0.8 65 7.0

31000803 3 x 2 x 0.8 85 8.6

31000804 4 x 2 x 0.8 105 9.1

31000805 5 x 2 x 0.8 125 9.6

31000806 6 x 2 x 0.8 150 11.2

31000808 8 x 2 x 0.8 180 11.7

31000810 10 x 2 x 0.8 225 13.3

31000812 12 x 2 x 0.8 255 14.0

31000816 16 x 2 x 0.8 320 16.1

31000820 20 x 2 x 0.8 385 17.0

31000824 24 x 2 x 0.8 470 19.1

31000830 30 x 2 x 0.8 570 20.9

31000840 40 x 2 x 0.8 715 23.2

31000850 50 x 2 x 0.8 900 26.2

31000860 60 x 2 x 0.8 1050 28.1

31000880 80 x 2 x 0.8 1450 31.6

310008100 100 x 2 x 0.8 1800 33.0

31000602

Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please callto check availability.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

71J-H(St)H: LSHF Screened TELEPHONE

J-H(St)H was originally developed in Germany for internal wiring in sensitive areas. A number of things set this apart fromthe UK internal telephone cable CW1308. The major differences are it is LSHF throughout, screened, comes in 0.6mm or0.8mm conductor size and has a completely different colour code. It is now finding popularity for wiring everything fromintercom and nurse call systems right through to sophisticated security installations where the benefits of a screened LSHFlow resistance cable make it an ideal choice.

J-H(St)H: LSHF Screened Telephone Cable

Construction

Plain copper wire conductors to IEC 60228 class 1, LSHF

insulation, overall foil screen in contact with plain copper

drain wire, LSHF sheath – grey.

Technical Information

Voltage Rating: 300V

Conductor Stranding: Solid IEC 60228 class 1

Temperature Rating: Static -30°C to +70°C

Flexing -5°C to +50°C

Bending Radius: Fixed 7.5 x overall diameter

Flame Retardant: IEC 60332-3-24 Cat C

Halogen Emissions: IEC 60754-2, BS EN 50267

Smoke Emissions: IEC 61034-2, BS EN 50268

J-H(St)H can be also be supplied with a red outer jacket for

identifying permitted fire alarm systems, please put ‘03’ at the end

of the part number to specify this cable.

Core Identification

Colour code according to DIN VDE 0815.

Part No. Pairs x Weight O/Dmm kg/km mm

31000602H 2 x 2 x 0.6 45 5.0

31000603H 3 x 2 x 0.6 55 6.4

31000604H 4 x 2 x 0.6 65 6.6

31000605H 5 x 2 x 0.6 75 7.3

31000606H 6 x 2 x 0.6 85 7.5

31000608H 8 x 2 x 0.6 95 8.0

31000610H 10 x 2 x 0.6 115 10.1

31000612H 12 x 2 x 0.6 130 10.4

31000616H 16 x 2 x 0.6 155 11.0

31000620H 20 x 2 x 0.6 200 12.1

31000624H 24 x 2 x 0.6 225 13.2

31000630H 30 x 2 x 0.6 285 14.0

31000640H 40 x 2 x 0.6 355 15.1

31000650H 50 x 2 x 0.6 440 17.3

31000660H 60 x 2 x 0.6 510 19.2

31000680H 80 x 2 x 0.6 650 21.3

310006100H 100 x 2 x 0.6 850 24.0

Part No. Pairs x Weight O/Dmm kg/km mm

31000802H 2 x 2 x 0.8 65 7.0

31000803H 3 x 2 x 0.8 85 8.6

31000804H 4 x 2 x 0.8 105 9.1

31000805H 5 x 2 x 0.8 125 9.6

31000806H 6 x 2 x 0.8 150 11.2

31000808H 8 x 2 x 0.8 180 11.7

31000810H 10 x 2 x 0.8 225 13.3

31000812H 12 x 2 x 0.8 255 14.0

31000816H 16 x 2 x 0.8 320 16.1

31000820H 20 x 2 x 0.8 385 17.0

31000824H 24 x 2 x 0.8 470 19.1

31000830H 30 x 2 x 0.8 570 20.9

31000840H 40 x 2 x 0.8 715 23.2

31000850H 50 x 2 x 0.8 900 26.2

31000860H 60 x 2 x 0.8 1050 28.1

31000880H 80 x 2 x 0.8 1450 31.6

310008100H 100 x 2 x 0.8 1800 33.0

31000602H

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable idealfor use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000Vgrade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oilsis required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times.

YY PVC Multicore

Construction

Fine copper wire strands to IEC 60228 class 5 or class 6

depending on cross section. PVC insulation with either

number or colour coding. A green/yellow earth core is

normally included in cables with more than 2 cores in

0.5mm2 and above. Cores twisted together, grey PVC sheath.

Technical Information

Voltage Rating: 300/500V Test 3000VTemperature Rating: Static -20°C to +80°C

Flexing -5°C to +70°CMinimum Bending Radius: Static 6 x cable diameter

Flexing 15 x cable diameter

Current Rating: Refer to IEE Regs Table 4F3A&B

10001507

Part No. Cores x Weight O/Dmm² kg/km mm

YY Multicore Cable Number Coded10000502 2 x 0.5 33 4.910000503 3 x 0.5 43 5.210000504 4 x 0.5 46 5.710000505 5 x 0.5 53 6.410000507 7 x 0.5 75 6.610000512 12 x 0.5 113 8.910000518 18 x 0.5 167 10.710000521 21 x 0.5 194 11.710000540 40 x 0.5 347 15.5

10000702 2 x 0.75 41 5.210000703 3 x 0.75 54 5.710000704 4 x 0.75 58 6.110000705 5 x 0.75 69 6.710000707 7 x 0.75 97 7.210000708 8 x 0.75 109 8.610000710 10 x 0.75 133 9.310000712 12 x 0.75 151 9.910000718 18 x 0.75 216 11.510000721 21 x 0.75 263 13.810000725 25 x 0.75 296 14.110000734 34 x 0.75 392 15.910000741 41 x 0.75 466 16.910000742 42 x 0.75 496 17.610000750 50 x 0.75 585 19.310000761 61 x 0.75 693 20.9

10001002 2 x 1.0 50 5.510001003 3 x 1.0 60 5.910001004 4 x 1.0 63 6.610001005 5 x 1.0 81 7.1 10001007 7 x 1.0 126 7.610001010 10 x 1.0 157 9.910001012 12 x 1.0 183 10.5

10001018 18 x 1.0 266 12.410001021 21 x 1.0 313 14.210001025 25 x 1.0 356 14.710001034 34 x 1.0 469 16.610001041 41 x 1.0 588 18.310001042 42 x 1.0 601 18.510001050 50 x 1.0 691 19.910001080 80 x 1.0 1099 24.6

10001502 2 x 1.5 64 6.210001503 3 x 1.5 80 6.610001504 4 x 1.5 99 7.310001505 5 x 1.5 112 7.910001507 7 x 1.5 150 8.910001510 10 x 1.5 212 11.210001512 12 x 1.5 250 11.710001514 14 x 1.5 289 12.810001518 18 x 1.5 362 13.910001521 21 x 1.5 426 15.510001525 25 x 1.5 515 17.210001532 32 x 1.5 634 18.710001534 34 x 1.5 671 19.310001542 42 x 1.5 836 20.410001550 50 x 1.5 973 22.610001561 61 x 1.5 1181 25.210001565 65 x 1.5 1359 26.8

10002502 2 x 2.5 96 7.610002503 3 x 2.5 125 8.010002504 4 x 2.5 152 8.810002505 5 x 2.5 173 9.810002507 7 x 2.5 238 11.910002512 12 x 2.5 384 14.510002518 18 x 2.5 559 17.4

Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and forguidance only and will vary from one manufacture to another. If the O/D is critical please check at time of order and wewill measure it.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

72 SIGNAL & CONTROL YY PVC

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

73YY PVC SIGNAL & CONTROL

10001502C 2 x 1.5 64 6.210001503C 3 x 1.5 80 6.610001504E 4 x 1.5 99 7.310001505E 5 x 1.5 112 7.910001507C 7 x 1.5 150 8.910001512C 12 x 1.5 250 11.7

10002502C 2 x 2.5 96 7.610002503C 3 x 2.5 125 8.010002504E 4 x 2.5 152 8.810002505E 5 x 2.5 173 9.810002507C 7 x 2.5 238 11.910002512C 12 x 2.5 384 14.5

10004003C 3 x 4.0 260 11.910004004E 4 x 4.0 302 12.610004005E 5 x 4.0 359 13.810004007C 7 x 4.0 482 15.5

10006003C 3 x 6.0 319 12.810006004E 4 x 6.0 396 13.710006005E 5 x 6.0 493 15.810006007C 7 x 6.0 660 17.5

10010003C 3 x 10 521 16.110010004E 4 x 10 655 17.710010005E 5 x 10 798 19.810010007C 7 x 10 1063 21.8

10016003C 3 x 16 920 18.410016004E 4 x 16 1095 20.610016005E 5 x 16 1379 22.9

10025003C 3 x 25 1371 23.210025004E 4 x 25 1592 25.610025005E 5 x 25 2012 28.4

10035003C 3 x 35 1782 25.710035004E 4 x 35 2151 28.610035005E 5 x 35 2863 31.8

10050003C 3 x 50 2561 31.110050004E 4 x 50 2983 34.810050005E 5 x 50 3860 38.5

10070003C 3 x 70 3215 35.510070004E 4 x 70 4123 39.410070005E 5 x 70 4834 44.3

10095003C 3 x 95 4721 41.510095004E 4 x 95 5583 45.910095005E 5 x 95 6513 50.3

10120004E 4 x 120 7135 52.3

Blue Brown

Blue Brown Green/Yellow

Colour Code:

2 core

3 core

4 core

5 core

Blue Black Grey Green/Yellow

Blue Brown Black Grey Green/Yellow

10002521 21 x 2.5 737 21.510002525 25 x 2.5 793 22.110002534 34 x 2.5 1086 23.810002550 50 x 2.5 1579 28.9

10004003 3 x 4.0 182 9.710004004 4 x 4.0 235 10.610004005 5 x 4.0 276 11.810004007 7 x 4.0 358 13.0

10006003 3 x 6.0 273 11.910006004 4 x 6.0 337 12.810006005 5 x 6.0 407 14.310006007 7 x 6.0 498 16.7

10010004 4 x 10 532 15.810010005 5 x 10 675 17.910010007 7 x 10 894 19.5

10016004 4 x 16 849 19.210016005 5 x 16 1053 21.710016007 7 x 16 1389 23.8

10025004 4 x 25 1275 23.310025005 5 x 25 1580 25.910025007 7 x 25 2109 28.5

10035004 4 x 35 1686 27.310035005 5 x 35 2106 29.6

10050004 4 x 50 2534 32.1

10070004 4 x 70 3365 36.3

10095004 4 x 95 4535 41.4

10120004 4 x 120 5486 45.3

YY Multicore Cable Colour Coded

10000702C 2 x 0.75 41 5.210000703C 3 x 0.75 54 5.710000704E 4 x 0.75 58 6.110000705E 5 x 0.75 69 6.710000707C 7 x 0.75 97 7.210000712C 12 x 0.75 151 9.9

10001002C 2 x 1.0 50 5.510001003C 3 x 1.0 60 5.910001004E 4 x 1.0 63 6.610001005E 5 x 1.0 81 7.110001007C 7 x 1.0 126 7.610001012C 12 x 1.0 183 10.5

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable idealfor use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000Vgrade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oilsis required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times.

LiYY Miniature Signal Cable with DIN 47100

Construction

Fine copper wire strands to IEC 60228 class 5 or class 6

depending on cross section. PVC insulation with DIN 47100

colour coding. Cores twisted together, grey PVC sheath.

Technical Information

Voltage Rating: 0.14mm2 - 0.34mm2: Working 250V Test 1200V0.5mm2 and above: Working 300/500V Test 3000V

Temperature Rating: Static -20°C to +80°C Flexing -5°C to +70°C

Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter

Current Rating: Refer to IEE Regs Table 4F3A&B

Part No. Cores x Weight O/Dmm² kg/km mm

LiYY Miniature Signal Cable with DIN 47100Colour Code

30000102 2 x 0.14 12 3.330000103 3 x 0.14 15 3.530000104 4 x 0.14 17 3.730000105 5 x 0.14 22 4.030000107 7 x 0.14 26 4.730000112 12 x 0.14 43 5.730000118 18 x 0.14 65 7.230000121 21 x 0.14 79 7.530000125 25 x 0.14 93 8.130000132 32 x 0.14 112 8.830000140 40 x 0.14 132 9.630000152 52 x 0.14 177 10.930000161 61 x 0.14 204 11.6

30000202 2 x 0.25 25 3.730000203 3 x 0.25 29 3.930000204 4 x 0.25 31 4.230000205 5 x 0.25 38 4.630000207 7 x 0.25 48 5.330000212 12 x 0.25 75 7.130000218 18 x 0.25 110 8.230000221 21 x 0.25 128 8.530000225 25 x 0.25 146 9.830000232 32 x 0.25 186 10.730000240 40 x 0.25 207 11.530000252 52 x 0.25 258 12.830000261 61 x 0.25 324 13.9

Part No. Cores x Weight O/Dmm² kg/km mm

30000302 2 x 0.34 28 4.4

30000303 3 x 0.34 30 4.6

30000304 4 x 0.34 40 4.9

30000305 5 x 0.34 44 5.6

30000307 7 x 0.34 60 6.2

30000312 12 x 0.34 88 8.1

30000318 18 x 0.34 135 9.7

30000321 21 x 0.34 151 10.4

30000325 25 x 0.34 181 11.5

30000332 32 x 0.34 223 12.4

30000340 40 x 0.34 266 13.5

30000352 52 x 0.34 337 15.5

30000361 61 x 0.34 392 16.5

30000502 2 x 0.5 31 4.9

30000503 3 x 0.5 35 5.2

30000504 4 x 0.5 42 5.7

30000505 5 x 0.5 49 6.2

30000507 7 x 0.5 73 7.2

30000512 12 x 0.5 130 9.2

30000518 18 x 0.5 166 11.3

30000521 21 x 0.5 185 13.1

30000525 25 x 0.5 250 13.4

30000532 32 x 0.5 291 14.7

30000540 40 x 0.5 345 16.1

30000552 52 x 0.5 454 19.7

30000561 61 x 0.5 536 20.4

The cables above are colour coded to DIN 47100. This colour code can be found on page 80. Other core counts and sizesare available please ask for more details. Overall diameters (O/D) are approximate and for guidance only and will varyfrom one manufacture to another. If the O/D is critical please check at time of order and we will measure it.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

74 SIGNAL & CONTROL LiYY PVC Multicore

30000325

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

75Niltox LF-318 LSHF SIGNAL & CONTROL

Construction

Fine copper wire strands to IEC 60228 class

5, halogen free insulation, colour coded to

BS 7671 HD 308 S2. White or black Low

Smoke Halogen Free outer sheath.

Technical Information

Voltage Rating: 300/500V Test 3000V

Temperature Rating: Flexing +5°C to +70°C

Static -20°C to +90°C

Bending Radius: Flexing 15 x cable diameter

Static 7.5 x cable diameter

Current Rating: Refer to IEE Regs Table 4F3A&B

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Part No. Cores x Weight O/Dmm² kg/km mm

31800702xx 2 x 0.75 60 6.3

31800703xx 3 x 0.75 70 6.7

31800704xx 4 x 0.75 88 7.1

31800705xx 5 x 0.75 112 7.8

31801002xx 2 x 1.0 71 6.7

31801003xx 3 x 1.0 84 7.1

31801004xx 4 x 1.0 106 7.9

31801005xx 5 x 1.0 134 8.7

31801006xx 6 x 1.0 163 9.8

31801502xx 2 x 1.5 97 7.7

31801503xx 3 x 1.5 120 8.3

31801504xx 4 x 1.5 152 9.4

31801505xx 5 x 1.5 183 10.4

31801506xx 6 x 1.5 201 10.1

Part No. Cores x Weight O/Dmm² kg/km mm

31802502xx 2 x 2.5 150 9.1

31802503xx 3 x 2.5 184 9.8

31802504xx 4 x 2.5 228 10.9

31802505xx 5 x 2.5 270 11.9

31804003xx 3 x 4 216 14.0

31804004xx 4 x 4 286 15.1

31804005xx 5 x 4 342 15.4

31806004xx 4 x 6 338 15.2

31806005xx 5 x 6 422 17.5

31810004xx 4 x 10 690 22.1

31810005xx 5 x 10 884 24.9

Low Smoke Halogen Free compounds are used to produce this high quality flexible cable that meetsthe requirements of 318* B and HO5ZZ-F. Niltox LF-318 is ideal for applications where the cable willbe visible. Examples include: lighting pendant drops, supply leads and general wiring in public areas.

As an option these cables can be oversheathed in a wide variety of colours in Low Smoke HalogenFree compounds. This is particularly useful when quantities are small or cables are needed quickly.

Niltox® LF-318 LSHF Colour Coded Multicore

To show the colour required please replace xx in the part number with:

04 White 00 Black

3180150404

3180150300

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Developed to meet the need for Low Smoke Halogen Free control cables, the Niltox LF-319 range covers all the popular sizes.Applications include airports, hospitals, lift shafts, tunnels, heating and ventilating controls, in fact anywhere that conventionalPVC YY cables were previously used. In addition to its LSHF properties this cable offers a high degree of flame retardance therebyreducing the risk of spreading fire. Stocked on bulk reels, Niltox LF-319 cables can be cut to the length you require.

Niltox® LF-319 LSHF Multicore

Construction

Fine copper wire strands to IEC 60228 class 5, Low Smoke

Halogen Free insulation, black cores with white number

coding, a green/yellow earth core is included in cables with

more than 2 cores, grey Low Smoke Halogen Free outer

sheath.

Technical Information

Voltage Rating: 300/500V Test 2000VTemperature Rating: Flexing +5ºC to +70ºC

Static -20ºC to +90ºCBending Radius: Flexing 15 x cable diameter

Static 7.5 x cable diameterCurrent Rating: Refer to IEE Regs Table 4F3A&BFlame Retardant: IEC 60332-1-2, IEC 60332-3-24C, UL 1685Smoke Emission: IEC 61034-2, UL 1685Halogen Emission: IEC 60754-1 & 2

Part No. Cores x Weight O/Dmm² kg/km mm

Number Coded

31900702 2 x 0.75 45 5.5

31900703 3 x 0.75 55 5.6

31900704 4 x 0.75 65 6.5

31900705 5 x 0.75 76 7.3

31900707 7 x 0.75 93 7.5

31900712 12 x 0.75 140 9.1

31900718 18 x 0.75 240 12.5

31900725 25 x 0.75 343 14.3

31900730 30 x 0.75 470 15.5

31900734 34 x 0.75 225 16.5

31900741 41 x 0.75 620 17.8

31900750 50 x 0.75 750 19.8

31901002 2 x 1.0 49 6.0

31901003 3 x 1.0 59 6.5

31901004 4 x 1.0 75 6.7

31901005 5 x 1.0 88 7.5

31901007 7 x 1.0 112 8.0

31901012 12 x 1.0 170 10.2

31901018 18 x 1.0 252 12.0

31901025 25 x 1.0 363 15.0

31901034 34 x 1.0 685 17.6

31901041 41 x 1.0 790 18.8

31901050 50 x 1.0 870 21.2

Part No. Cores x Weight O/Dmm² kg/km mm

31901502 2 x 1.5 73 6.8

31901503 3 x 1.5 78 7.1

31901504 4 x 1.5 105 7.6

31901505 5 x 1.5 133 9.0

31901507 7 x 1.5 165 9.5

31901512 12 x 1.5 274 12.0

31901518 18 x 1.5 402 15.5

31901525 25 x 1.5 533 16.5

31901534 34 x 1.5 850 19.9

31901550 50 x 1.5 1285 23.9

31901561 61 x 1.5 1475 25.4

31901565 65 x 1.5 1650 26.2

31902502 2 x 2.5 94 7.7

31902503 3 x 2.5 123 8.7

31902504 4 x 2.5 158 9.3

31902505 5 x 2.5 192 10.1

31902507 7 x 2.5 246 12.5

31902512 12 x 2.5 360 13.5

31902518 18 x 2.5 780 18.3

31902525 25 x 2.5 1050 22.1

31904002 2 x 4.0 172 9.3

31904003 3 x 4.0 185 9.9

31904004 4 x 4.0 198 10.1

31904005 5 x 4.0 270 12.5

31904007 7 x 4.0 475 13.5

31904012 12 x 4.0 800 18.5

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

76 SIGNAL & CONTROL Niltox® LF-319 LSHF

Also available with a black sheath in some sizes. Other sizes are available on short lead times.

31901507

Part No. Cores x Weight O/Dmm² kg/km mm

31906002 2 x 6.0 243 10.9

31906003 3 x 6.0 260 11.5

31906004 4 x 6.0 285 12.0

31906005 5 x 6.0 420 14.5

31906007 7 x 6.0 640 16.2

31910003 3 x 10 550 15.1

31910004 4 x 10 710 16.9

31910005 5 x 10 875 18.9

31916003 3 x 16 850 17.8

31916004 4 x 16 1050 20.0

31916005 5 x 16 1300 22.2

31925003 3 x 25 1150 22.6

31925004 4 x 25 1600 25.5

31925005 5 x 25 2100 28.1

31935003 3 x 35 1600 25.5

31935004 4 x 35 2210 28.3

31935005 5 x 35 2700 31.3

31950003 3 x 50 2600 30.0

31950004 4 x 50 3100 33.7

31950005 5 x 50 4000 37.4

31970003 3 x 70 3250 37.2

31970004 4 x 70 4100 41.4

31970005 5 x 70 5500 46.2

31995003 3 x 95 4750 41.5

31995004 4 x 95 5600 46.3

31995005 5 x 95 7000 50.8

31912003 3 x 120 5600 46.0

31912004 4 x 120 7150 50.5

Part No. Cores x Weight O/Dmm² kg/km mm

Colour Coded

31901502C 2 x 1.5 73 6.8

31901503C 3 x 1.5 78 7.1

31901504E 4 x 1.5 105 7.6

31901505E 5 x 1.5 133 9.0

31902502C 2 x 2.5 94 7.7

31902503C 3 x 2.5 123 8.7

31902504E 4 x 2.5 158 9.3

31902505E 5 x 2.5 192 10.1

31904003C 3 x 4.0 185 10.0

31904004E 4 x 4.0 198 10.1

31904005E 5 x 4.0 270 12.5

31906003C 3 x 6.0 260 11.5

31906004E 4 x 6.0 285 12.0

31906005E 5 x 6.0 420 14.5

31910003C 3 x 10 550 15.1

31910004C 4 x 10 710 16.9

31910005C 5 x 10 875 18.9

31916003C 3 x 16 850 17.8

31916004C 4 x 16 1050 20.0

31916005C 5 x 16 1300 22.2

31925003C 3 x 25 1150 22.6

31925004C 4 x 25 1600 25.5

31925005C 5 x 25 2100 28.1

31935003C 3 x 35 1600 25.5

31935004C 4 x 35 2210 28.3

31935005C 5 x 35 2700 31.3

31950003C 3 x 50 2600 30.0

31950004C 4 x 50 3100 33.7

31950005C 5 x 50 4000 37.4

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

77Niltox® LF-319 LSHF SIGNAL & CONTROL

Blue Brown

Blue Brown Green/Yellow

Colour Code:

2 core

3 core

4 core

5 core

Blue Black Grey Green/Yellow

Blue Brown Black Grey Green/Yellow

LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI) and reducingelectromagnetic radiation (EMR). This can be important when trying to ensure electromagnetic compatibility (EMC). The braid screened LiYCY miniature signal and data cable range is available colour coded to DIN 47100. Larger core sizesover 0.5mm2 are also available number coded or colour coded.

These cables are also available unscreened type LiYY with part numbers starting 300 please see page 74, or with the corestwisted into pairs and overall screens known as LiYCY-TP, part numbers starting 325 please see page 80-81; or twisted pairswithout a screen LiYY-TP - part numbers starting 305.

For Low Smoke Halogen Free types, please see the LF-315 & LF 329 range, pages 84 and pages 82-83 respectively.

LiYCY PVC Screened Multicore

Construction

Fine copper wire strands to IEC 60228. PVC insulation

colour or number coded. Cores twisted together with

overall polyester tape and tinned copper wire braid.

Grey PVC outer sheath.

Core Identification

0.14mm2 - 0.34mm2. Colour Coded to DIN 47100.

Part numbers end in F.

0.5mm2 - 35mm2. Black cores with white numbers + G/Y.

Part numbers have no suffix.

Technical Information

Voltage Rating: 0.14mm2 - 0.34mm2: Working 250V Test 1000V

0.5mm2 - 1.5mm2: Working 300V Test 2000V

2.5mm2 - 6mm2: Working 500V Test 2000V

Temperature Rating: Static -20°C to +80°C Flexing -5°C to +70°C

Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter

Conductor Stranding: Flexible to IEC 60228 Class 5 on 0.5mm2 and above.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

78 SIGNAL & CONTROL LiYCY PVC

32001503C

Part No. Cores x mm2 Weight kg/km O/D mm

Colour Coded to BS7671 HD 308 S2

32000702C 2 x 0.75 56 6.732000703C 3 x 0.75 70 7.132000704E 4 x 0.75 95 7.632000705E 5 x 0.75 130 8.2

32001002C 2 x 1 84 7.732001003C 3 x 1 110 8.532001004E 4 x 1 130 9.232001005E 5 x 1 156 9.9

32001502C 2 x 1.5 97 8.132001503C 3 x 1.5 125 8.932001504E 4 x 1.5 165 9.732001505E 5 x 1.5 193 10.5

32002502C 2 x 2.5 148 10.132002503C 3 x 2.5 188 10.632002504E 4 x 2.5 236 11.632002505E 5 x 2.5 270 12.6

32004003C 3 x 4.0 250 12.432004004E 4 x 4.0 302 13.532004005E 5 x 4.0 370 14.8

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

79LiYCY PVC SIGNAL & CONTROL

32000325F

32000302F 2 x 0.34 33 5.032000303F 3 x 0.34 42 5.432000304F 4 x 0.34 49 5.8 32000305F 5 x 0.34 59 6.1 32000306F 6 x 0.34 64 6.632000307F 7 x 0.34 69 6.7 32000308F 8 x 0.34 84 7.4 32000310F 10 x 0.34 106 8.5 32000312F 12 x 0.34 119 8.7 32000314F 14 x 0.34 132 9.1 32000316F 16 x 0.34 146 9.632000318F 18 x 0.34 188 10.132000321F 21 x 0.34 193 10.9 32000325F 25 x 0.34 213 12.0 32000327F 27 x 0.34 232 12.3 32000330F 30 x 0.34 253 12.7 32000336F 36 x 0.34 292 13.6 32000340F 40 x 0.34 318 14.0 32000352F 52 x 0.34 400 15.832000361F 61 x 0.34 454 16.6

32000502 2 x 0.5 42 5.4 32000503 3 x 0.5 51 5.832000504 4 x 0.5 61 6.532000507 7 x 0.5 98 7.8 32000512 12 x 0.5 156 10.1 32000518 18 x 0.5 215 11.8 32000525 25 x 0.5 314 14.4

32000702 2 x 0.75 56 6.7 32000703 3 x 0.75 70 7.132000704 4 x 0.75 95 7.6 32000705 5 x 0.75 130 8.2 32000707 7 x 0.75 168 8.932000712 12 x 0.75 232 12.0 32000718 18 x 0.75 315 13.9 32000725 25 x 0.75 418 16.532000730 30 x 0.75 500 18.0

32001002 2 x 1 84 7.732001003 3 x 1 110 8.532001004 4 x 1 130 9.232001005 5 x 1 156 9.932001007 7 x 1 192 10.732001012 12 x 1 265 13.732001018 18 x 1 380 15.932001025 25 x 1 475 17.532001034 34 x 1 629 21.5

32001502 2 x 1.5 97 8.132001503 3 x 1.5 125 8.932001504 4 x 1.5 165 9.732001505 5 x 1.5 193 10.532001507 7 x 1.5 245 11.332001512 12 x 1.5 365 14.532001518 18 x 1.5 553 16.932001525 25 x 1.5 720 20.132001530 30 x 1.5 776 20.732001542 42 x 1.5 1140 25.5

32002502 2 x 2.5 148 10.132002503 3 x 2.5 188 10.632002504 4 x 2.5 236 11.632002505 5 x 2.5 270 12.632002507 7 x 2.5 340 13.732002512 12 x 2.5 585 18.532002518 18 x 2.5 725 19.7

32004003 3 x 4 250 12.432004004 4 x 4 302 13.532004005 5 x 4 370 14.832004007 7 x 4 473 16.1

32006003 3 x 6 285 13.932006004 4 x 6 412 15.232006005 5 x 6 505 16.7

32010004 4 x 10 620 20.832010005 5 x 10 796 22.9

32016004 4 x 16 1090 23.232016005 5 x 16 2070 25.6

32025004 4 x 25 1787 28.232025005 5 x 25 2047 31.1

32035004 4 x 35 2142 31.5

32000101F 1 x 0.14 16 3.6 32000102F 2 x 0.14 20 3.8 32000103F 3 x 0.14 25 4.0 32000104F 4 x 0.14 30 4.3 32000105F 5 x 0.14 36 4.6 32000106F 6 x 0.14 40 5.0 32000107F 7 x 0.14 41 5.2 32000108F 8 x 0.14 44 5.6 32000110F 10 x 0.14 56 6.3 32000112F 12 x 0.14 60 6.4 32000114F 14 x 0.14 65 6.7 32000116F 16 x 0.14 81 7.2 32000118F 18 x 0.14 93 7.6 32000121F 21 x 0.14 103 8.3 32000124F 24 x 0.14 117 9.0 32000125F 25 x 0.14 120 9.0 32000127F 27 x 0.14 124 9.1 32000130F 30 x 0.14 136 9.4 32000136F 36 x 0.14 160 10.0 32000140F 40 x 0.14 170 10.3 32000144F 44 x 0.14 186 11.1 32000152F 52 x 0.14 200 11.5 32000161F 61 x 0.14 250 12.1

32000201F 1 x 0.25 17 3.7 32000202F 2 x 0.25 30 4.5 32000203F 3 x 0.25 37 5.1 32000204F 4 x 0.25 44 5.2 32000205F 5 x 0.25 51 5.7 32000206F 6 x 0.25 55 6.1 32000207F 7 x 0.25 60 6.4 32000208F 8 x 0.25 77 7.1 32000210F 10 x 0.25 93 8.1 32000212F 12 x 0.25 104 8.4 32000214F 14 x 0.25 115 8.7 32000216F 16 x 0.25 132 8.9 32000218F 18 x 0.25 137 9.4 32000221F 21 x 0.25 173 10.4 32000224F 24 x 0.25 184 11.432000225F 25 x 0.25 190 11.5 32000227F 27 x 0.25 198 11.6 32000230F 30 x 0.25 212 11.932000236F 36 x 0.25 238 12.732000240F 40 x 0.25 260 13.132000244F 44 x 0.25 290 14.3 32000252F 52 x 0.25 333 14.9 32000261F 61 x 0.25 382 15.8

Popular as a European alternative to the American style data cables, LiYCY-TP has the cores twisted into pairs to reducecross talk. The DIN 47100 colour code makes it easy to identify each conductor. The effects of electro magnetic interference(EMI) are also minimised by the use of an overall tinned copper wire braid screen. Used extensively for signal & datatransmission where flexibility is important LiYCY-TP are designed for fixed or occasional movement although the cableconstruction make installation and routing through confined spaces simple.

LiYCY TP PVC Screened Paired Cables

Construction

Plain copper wire conductors to IEC 60228 class 5, PVC

insulation, cores twisted in pairs, overall tinned copper

wire braid, PVC sheath – Grey.

LiHCH-TP which is an LSHF version is also available,

please see page 85 for more details.

DIN 47100 European Colour Codes

The DIN 47100 standard specifies the core colour for up to 44 cores. Above this it is usual practice to repeat

the colours. The first colour is the colour of the base insulation and the second colour is that of either a

longitudinal stripe or printed rings.

Technical Information

Voltage Rating: ≤ 0.34mm² = 300V

≥ 0.5mm² = 300/500V

Conductor Stranding: Stranded to IEC 60228 class 5

Temperature Rating: Static -30°C to +80°C

Flexing -5 to +70°C

Bending Radius: Static 5 x overall diameter

Flexing 10 x overall diameter

Flame Retardant: VDE 0472 test B, IEC 60332-1-2, EN 50265-2-1

Manufactured To: VDE 0814

Colour code: DIN 47100

1 White 16 Yellow/Brown 31 Green/Blue

2 Brown 17 White/Grey 32 Yellow/Blue

3 Green 18 Grey/Brown 33 Green/Red

4 Yellow 19 White/Pink 34 Yellow/Red

5 Grey 20 Pink/Brown 35 Green/Black

6 Pink 21 White/Blue 36 Yellow/Black

7 Blue 22 Brown/Blue 37 Grey/Blue

8 Red 23 White/Red 38 Pink/Blue

9 Black 24 Brown/Red 39 Grey/Red

10 Violet 25 White/Black 40 Pink/Red

11 Grey/Pink 26 Brown/Black 41 Grey/Black

12 Red/Blue 27 Grey/Green 42 Pink/Black

13 White/Green 28 Yellow/Grey 43 Blue/Black

14 Brown/Green 29 Pink/Green 44 Red/Black

15 White/Yellow 30 Yellow/Pink

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

80 SIGNAL & CONTROL LiYCY TP PVC

32500506F

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

81LiYCY TP PVC SIGNAL & CONTROL

Part No. Pairs Weight O/Dx mm2 kg/km mm

Part No. Pairs Weight O/Dx mm2 kg/km mm

32500302F 2 x 2 x 0.34 65 7.132500303F 3 x 2 x 0.34 87 7.832500304F 4 x 2 x 0.34 115 8.532500305F 5 x 2 x 0.34 121 9.432500306F 6 x 2 x 0.34 139 9.932500307F 7 x 2 x 0.34 149 10.132500308F 8 x 2 x 0.34 165 10.932500310F 10 x 2 x 0.34 232 12.232500312F 12 x 2 x 0.34 239 13.332500314F 14 x 2 x 0.34 248 13.632500316F 16 x 2 x 0.34 267 14.632500318F 18 x 2 x 0.34 296 15.732500321F 21 x 2 x 0.34 308 16.332500325F 25 x 2 x 0.34 410 18.132500330F 30 x 2 x 0.34 451 19.232500334F 34 x 2 x 0.34 525 20.332500340F 40 x 2 x 0.34 623 21.632500344F 44 x 2 x 0.34 648 22.432500350F 50 x 2 x 0.34 714 23.8

32500502F 2 x 2 x 0.50 102 7.832500503F 3 x 2 x 0.50 135 8.432500504F 4 x 2 x 0.50 159 9.532500505F 5 x 2 x 0.50 168 9.932500506F 6 x 2 x 0.50 210 11.332500508F 8 x 2 x 0.50 268 12.232500510F 10 x 2 x 0.50 315 13.632500512F 12 x 2 x 0.50 355 14.432500516F 16 x 2 x 0.50 475 16.832500520F 20 x 2 x 0.50 532 18.532500525F 25 x 2 x 0.50 623 20.232500532F 32 x 2 x 0.50 810 22.5

32500702F 2 x 2 x 0.75 109 8.532500703F 3 x 2 x 0.75 142 9.432500704F 4 x 2 x 0.75 179 10.232500705F 5 x 2 x 0.75 218 11.632500706F 6 x 2 x 0.75 247 12.232500708F 8 x 2 x 0.75 306 13.532500710F 10 x 2 x 0.75 356 15.232500712F 12 x 2 x 0.75 410 16.532500716F 16 x 2 x 0.75 550 19.032500720F 20 x 2 x 0.75 686 21.332500725F 25 x 2 x 0.75 810 22.9

32501002F 2 x 2 x 1.0 125 9.232501003F 3 x 2 x 1.0 165 10.332501004F 4 x 2 x 1.0 220 11.132501502F 2 x 2 x 1.5 172 10.332501503F 3 x 2 x 1.5 231 12.432501504F 4 x 2 x 1.5 270 13.7

32500102F 2 x 2 x 0.14 42 5.432500103F 3 x 2 x 0.14 51 6.032500104F 4 x 2 x 0.14 58 6.532500105F 5 x 2 x 0.14 77 7.232500106F 6 x 2 x 0.14 86 7.632500107F 7 x 2 x 0.14 88 7.732500108F 8 x 2 x 0.14 104 8.232500110F 10 x 2 x 0.14 128 9.032500112F 12 x 2 x 0.14 142 9.532500114F 14 x 2 x 0.14 160 10.132500116F 16 x 2 x 0.14 156 10.632500118F 18 x 2 x 0.14 178 11.332500120F 20 x 2 x 0.14 195 11.632500124F 24 x 2 x 0.14 239 12.532500125F 25 x 2 x 0.14 243 12.932500126F 26 x 2 x 0.14 249 13.132500130F 30 x 2 x 0.14 287 13.532500132F 32 x 2 x 0.14 298 13.632500134F 34 x 2 x 0.14 321 14.632500136F 36 x 2 x 0.14 330 14.732500140F 40 x 2 x 0.14 372 15.532500144F 44 x 2 x 0.14 385 16.232500146F 46 x 2 x 0.14 433 16.532500150F 50 x 2 x 0.14 450 17.5

32500202F 2 x 2 x 0.25 47 6.232500203F 3 x 2 x 0.25 58 6.732500204F 4 x 2 x 0.25 75 7.532500205F 5 x 2 x 0.25 90 8.132500206F 6 x 2 x 0.25 101 8.532500207F 7 x 2 x 0.25 123 9.032500208F 8 x 2 x 0.25 130 9.432500210F 10 x 2 x 0.25 168 10.332500212F 12 x 2 x 0.25 196 10.932500214F 14 x 2 x 0.25 218 12.132500216F 16 x 2 x 0.25 221 12.532500218F 18 x 2 x 0.25 250 13.432500220F 20 x 2 x 0.25 278 13.732500224F 24 x 2 x 0.25 334 14.632500225F 25 x 2 x 0.25 337 15.232500226F 26 x 2 x 0.25 346 15.832500230F 30 x 2 x 0.25 375 16.632500232F 32 x 2 x 0.25 403 16.932500234F 34 x 2 x 0.25 412 17.532500236F 36 x 2 x 0.25 421 17.932500240F 40 x 2 x 0.25 489 18.432500244F 44 x 2 x 0.25 508 19.132500246F 46 x 2 x 0.25 540 19.432500250F 50 x 2 x 0.25 640 20.5

Niltox LF-329 is a Low Smoke Halogen Free alternative to the popular PVC LiYCY screened signal, control & power cable.Available from 0.75mm2 to 120mm2 these cables are LSHF throughout. Flexibility is excellent making installation easy. Coreidentification is straightforward with cores being clearly number coded and a green/yellow earth core included in cableswith more than 2 cores. Applications include hospitals, airports, computer suites and control rooms, in fact anywherewhere power or signals need to be protected from electromagnetic radiation or from corrupting other cables or equipment.The LSHF properties protect both people and equipment.

Niltox® LF-329 Dual Screened LSHF Multicore

Construction

Fine copper wire strands to IEC 60228 class 5,

Low Smoke Halogen Free insulation, cores twisted

together, polyester tape, overall foil & tinned

copper wire braid, grey Low Smoke Halogen Free

sheath.

Cores are black with white numbers, a green/yellow

earth core is included in cables with more than

2 cores.

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Technical Information

Voltage Rating: 300/500V Test 2000V

Temperature Rating: Flexing +5°C to +70°C

Static -20°C to +90°C

Bending Radius: Flexing 10 x cable diameter

Static 7.5 x cable diameter

Flame Retardant: IEC 60332-1-2, IEC 60332-3-24C, UL 1685

Smoke Emission: IEC 61034-2, UL 1685

Halogen Emission: IEC 60754-1 & 2

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

82 SIGNAL & CONTROL Niltox® LF-329 LSHF

32900707

Number Coded

32900702 2 x 0.75 56 6.5

32900703 3 x 0.75 54 6.0

32900704 4 x 0.75 74 6.5

32900705 5 x 0.75 83 7.6

32900707 7 x 0.75 106 8.1

32900712 12 x 0.75 200 10.3

32900718 18 x 0.75 295 12.5

32900725 25 x 0.75 420 14.8

32901002 2 x 1.0 60 6.6

32901003 3 x 1.0 66 6.6

32901004 4 x 1.0 83 7.4

32901005 5 x 1.0 100 8.1

32901007 7 x 1.0 130 9.0

32901012 12 x 1.0 270 11.3

32901018 18 x 1.0 390 13.4

32901025 25 x 1.0 545 15.9

32901502 2 x 1.5 72 7.1

32901503 3 x 1.5 97 8.1

32901504 4 x 1.5 114 8.6

32901505 5 x 1.5 135 9.1

32901507 7 x 1.5 176 9.7

32901512 12 x 1.5 300 12.7

32901518 18 x 1.5 500 14.8

32901525 25 x 1.5 710 17.8

32902502 2 x 2.5 123 8.3

32902503 3 x 2.5 132 9.2

32902504 4 x 2.5 152 9.5

32902505 5 x 2.5 215 10.9

32902507 7 x 2.5 250 12.0

32902512 12 x 2.5 580 15.9

32904002 2 x 4.0 190 10.0

32904003 3 x 4.0 220 11.5

32904004 4 x 4.0 310 11.6

32904005 5 x 4.0 395 12.7

32904007 7 x 4.0 510 14.1

32906002 2 x 6.0 280 11.6

32906003 3 x 6.0 325 12.5

32906004 4 x 6.0 360 13.6

32906005 5 x 6.0 520 15.9

32906007 7 x 6.0 675 16.7

32910003 3 x 10 450 15.5

32910004 4 x 10 790 17.4

32910005 5 x 10 620 18.0

32916003 3 x 16 690 19.0

32916004 4 x 16 1300 22.7

32916005 5 x 16 2200 25.3

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

83Niltox® LF-329 LSHF SIGNAL & CONTROL

32925003 3 x 25 1450 23.3

32925004 4 x 25 1950 26.4

32925005 5 x 25 2450 29.5

32935003 3 x 35 2000 25.9

32935004 4 x 35 2575 30.5

32935005 5 x 35 3200 34.0

32950003 3 x 50 3100 30.2

32950004 4 x 50 3600 34.8

32950005 5 x 50 4800 40.0

32970003 3 x 70 3900 37.8

32970004 4 x 70 5000 41.4

32970005 5 x 70 6600 46.3

32995003 3 x 95 5700 41.3

32995004 4 x 95 6700 46.4

32995005 5 x 95 8400 51.5

32912003 3 x 120 6400 46.7

32912004 4 x 120 8500 51.2

Colour Coded

32901502C 2 x 1.5 72 7.1

32901503C 3 x 1.5 97 8.1

32901504C 4 x 1.5 114 8.6

32901505C 5 x 1.5 135 9.1

32902502C 2 x 2.5 123 8.3

32902503C 3 x 2.5 132 9.2

32902504C 4 x 2.5 152 9.5

32902505C 5 x 2.5 215 10.9

32904003C 3 x 4.0 220 11.5

32904004E 4 x 4.0 310 11.6

32904005E 5 x 4.0 395 12.7

32906003C 3 x 6.0 325 12.5

32906004E 4 x 6.0 360 13.6

32906005E 5 x 6.0 520 15.9

32910003C 3 x 10 450 15.5

32910004E 4 x 10 790 17.9

32910005E 5 x 10 620 18.0

32916003C 3 x 16 690 19.0

32916004E 4 x 16 1300 22.7

32916005E 5 x 16 2200 25.3

32925003C 3 x 25 1450 23.3

32925004E 4 x 25 1950 26.4

32925005E 5 x 25 2450 29.5

32935003C 3 x 35 2000 25.9

32935004E 4 x 35 2575 30.5

32935005E 5 x 35 3200 34.0

Blue Brown

Blue Brown Green/Yellow

Colour Code:

2 core

3 core

4 core

5 core

Blue Black Grey Green/Yellow

Blue Brown Black Grey Green/Yellow

Developed for signal and control applications in sensitive areas, the Niltox LF-315 range offers excellent flame retardancewhile emitting no halogens or other corrosive gases when exposed to fire. These cables are colour coded to the DIN 47100standard and offer excellent flexibility and durability.

Niltox® LF-315 Screened LSHF Multicore

Construction

Fine copper wire strands to IEC 60228. Low Smoke

Halogen Free insulation, colour coded cores twisted

together with overall PETP tape and tinned copper wire

braid. Flame retardant halogen free light grey sheath.

Technical Information

Voltage Rating: 0.14mm2:

300V Test 800V

0.25mm2 to 1.5mm2:

300/500V Test 1200V

Temperature Rating: Flexing -5°C to +70°C

Static -40°C to +80°C

Bending Radius: Flexing 15 x cable diameter

Static 7.5 x cable diameter

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Colour Code: DIN 47100 see page 80.

Part No. Cores x Weight O/Dmm² kg/km mm

31500102 2 x 0.14 18 3.9

31500103 3 x 0.14 22 4.1

31500104 4 x 0.14 24 4.3

31500105 5 x 0.14 29 4.7

31500107 7 x 0.14 32 5.2

31500110 10 x 0.14 46 6.5

31500112 12 x 0.14 53 6.9

31500118 18 x 0.14 72 7.8

31500202 2 x 0.25 21 4.3

31500203 3 x 0.25 23 4.4

31500204 4 x 0.25 27 4.7

31500205 5 x 0.25 34 5.3

31500207 7 x 0.25 41 5.7

31500210 10 x 0.25 55 7.3

31500212 12 x 0.25 64 7.5

31500218 18 x 0.25 89 9.0

31500302 2 x 0.34 25 5.0

31500303 3 x 0.34 30 5.2

31500304 4 x 0.34 36 5.6

31500305 5 x 0.34 44 6.3

31500307 7 x 0.34 54 6.9

31500310 10 x 0.34 76 8.9

31500312 12 x 0.34 86 9.1

Part No. Cores x Weight O/Dmm² kg/km mm

Other sizes and numbers of cores are often available on short delivery times, please ask for details.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

84 SIGNAL & CONTROL Niltox® LF-315 LSHF

31500712

31500502 2 x 0.5 42 5.3

31500503 3 x 0.5 49 5.6

31500504 4 x 0.5 64 6.2

31500505 5 x 0.5 79 6.9

31500507 7 x 0.5 99 7.4

31500512 12 x 0.5 142 9.8

31500702 2 x 0.75 49 5.9

31500703 3 x 0.75 64 6.4

31500704 4 x 0.75 81 7.1

31500705 5 x 0.75 106 7.7

31500707 7 x 0.75 122 8.7

31500712 12 x 0.75 187 11.0

31501002 2 x 1.0 61 6.1

31501003 3 x 1.0 82 6.8

31501004 4 x 1.0 102 7.2

31501005 5 x 1.0 119 8.4

31501007 7 x 1.0 149 9.1

31501502 2 x 1.5 76 7.1

31501503 3 x 1.5 104 7.9

31501504 4 x 1.5 117 8.4

31501505 5 x 1.5 149 9.3

31501507 7 x 1.5 188 10.4

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

85Niltox® LF-316 LSHF SIGNAL & CONTROL

31600506

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The Niltox LF-316 paired and screened range of Low Smoke Halogen Free data cables offer excellent flexibility anddurability. Identification of the cores is made easy due to the DIN 47100 colour code. The cable is screened with an overalltinned copper wire braid offering excellent protection from electromagnetic interference.

Niltox® LF-316 Screened LSHF Multipair

Construction

Fine copper wire strands to IEC 60228. Low Smoke

Halogen Free insulation, colour coded, two cores

twisted together to form a pair, pairs then twisted

together to form multipair cables, overall PETP tape

and overall tinned copper wire braid. Flame retardant

halogen free grey sheath.

Technical Information

Voltage Rating: 0.14mm2:

350V Test 800V

0.25mm2 to 0.75mm2:

500V Test 1200V

Temperature Rating: Flexing +5°C to +70°C

Static -40°C to +70°C

Bending Radius: 7.5 x cable diameter

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Colour Code: DIN 47100 see page 80.

Other sizes and pair counts are often available on short delivery times, please ask for details.

Part No. Pairs Weight O/Dx mm2 kg/km mm

31600102 2 x 2 x 0.14 36 5.3

31600103 3 x 2 x 0.14 47 6.2

31600104 4 x 2 x 0.14 65 7.4

31600106 6 x 2 x 0.14 86 8.1

31600107 7 x 2 x 0.14 94 8.7

31600112 12 x 2 x 0.14 134 10.7

31600201 1 x 2 x 0.25 21 4.5

31600202 2 x 2 x 0.25 44 5.9

31600203 3 x 2 x 0.25 65 7.1

31600204 4 x 2 x 0.25 80 8.0

31600206 6 x 2 x 0.25 114 9.0

31600207 7 x 2 x 0.25 121 9.4

31600212 12 x 2 x 0.25 173 11.0

31600302 2 x 2 x 0.34 67 7.3

31600303 3 x 2 x 0.34 91 8.5

31600304 4 x 2 x 0.34 109 9.5

31600306 6 x 2 x 0.34 140 10.0

31600307 7 x 2 x 0.34 155 11.0

31600312 12 x 2 x 0.34 246 14.5

Part No. Pairs Weight O/Dx mm2 kg/km mm

31600501 1 x 2 x 0.5 42 5.5

31600502 2 x 2 x 0.5 76 7.6

31600503 3 x 2 x 0.5 108 8.9

31600504 4 x 2 x 0.5 135 10.3

31600505 5 x 2 x 0.5 152 11.5

31600506 6 x 2 x 0.5 168 11.7

31600507 7 x 2 x 0.5 186 11.9

31600512 12 x 2 x 0.5 331 16.0

31600702 2 x 2 x 0.75 106 9.1

31600703 3 x 2 x 0.75 138 10.0

31600704 4 x 2 x 0.75 165 11.6

31600705 5 x 2 x 0.75 234 13.5

31600707 7 x 2 x 0.75 259 13.8

31600712 12 x 2 x 0.75 439 18.4

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

86 SIGNAL & CONTROL RiserFlex 0.6/1kV

32801504E

32802507

RiserFlex 0.6/1kV

Construction

Fine copper wire strands to IEC

60228 class 5, XLPE insulation, cores

laid up. Low Smoke Halogen Free

sheath – black.

Technical Information

Voltage Rating: Working 0.6/1kV Test 3.5kV

Temperature Rating: Static -20ºC to +80ºC

Bending Radius: Static 7.5 x cable diameter

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Oxygen Index: >30%

Core Identification: Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

32802502 2 x 2.5 158 9.3

32802503 3 x 2.5 194 9.7

32802504 4 x 2.5 240 10.8

32802505 5 x 2.5 284 12.2

32802507 7 x 2.5 361 13.1

32804003 3 x 4 228 12.3

32804004 4 x 4 299 13.8

32806003 3 x 6 301 14.1

32806004 4 x 6 356 15.6

32810003 3 x 10 684 16.5

32810004 4 x 10 882 18.4

32800702 2 x 0.75 63 6.032800703 3 x 0.75 74 6.632800704 4 x 0.75 93 7.132800705 5 x 0.75 118 8.032800707 7 x 0.75 147 9.4

32801002 2 x 1 75 8.9

32801003 3 x 1 89 7.4

32801004 4 x 1 112 8.2

32801005 5 x 1 141 9.032801007 7 x 1 178 10.0

32801502 2 x 1.5 102 7.932801503 3 x 1.5 126 8.6

32801504 4 x 1.5 159 9.3

32801505 5 x 1.5 192 10.4

32801507 7 x 1.5 231 11.132801512 12 x 1.5 390 16.6

Developed to meet the latest building requirements this Low Smoke Halogen Free cable is 0.6/1kVrated making it ideal to run in risers or under floors.

The conductors are finely stranded to IEC60228 class 5 making installation simple and routing easy.Cores are colour coded to BS7671 in cables up to 5 cores. Above this they are black with white numbers. Cores are also rated at 0.6/1kV to comply with regulations for power cables inprotected installations. Applications include wiring to computer systems, lift shafts, HVAC, securitysystems and BMS.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

87RiserShield 0.6/1kV SIGNAL & CONTROL

42601507

42606004E

RiserShield 0.6/1kV

Construction

Fine copper wire strands to IEC

60228 class 5, XLPE insulation, cores

laid up, overall foil and tinned copper

braid. Low Smoke Halogen Free

sheath – black.

Technical Information

Voltage Rating: Working 0.6/1kV Test 3.5kV

Temperature Rating: Static -40ºC to +80ºC

Bending Radius: Static 7.5 x cable diameter

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Oxygen Index: >30%

Core Identification: Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

42602502 2 x 2.5 206 10.3

42602503 3 x 2.5 263 10.8

42602504 4 x 2.5 299 11.9

42602505 5 x 2.5 329 13.0

42602507 7 x 2.5 471 14.4

42604003 3 x 4 295 16.2

42604004 4 x 4 376 17.4

42606003 3 x 6 390 19.2

42606004 4 x 6 459 20.8

42610003 3 x 10 882 25.3

42610004 4 x 10 1049 28.6

42600702 2 x 0.75 105 7.1

42600703 3 x 0.75 111 7.5

42600704 4 x 0.75 132 8.1

42600705 5 x 0.75 149 9.0

42600707 7 x 0.75 215 9.8

42601002 2 x 1 126 7.8

42601003 3 x 1 141 8.3

42601004 4 x 1 167 9.1

42601005 5 x 1 196 10.1

42601007 7 x 1 282 10.9

42601502 2 x 1.5 149 8.9

42601503 3 x 1.5 173 9.5

42601504 4 x 1.5 191 10.3

42601505 5 x 1.5 216 11.3

42601507 7 x 1.5 314 12.2

RiserShield is a 0.6/1kV dual screened power, control and signal cable using Low Smoke Halogen Freematerials throughout. Developed to run alongside power cables RiserShield is particularly popular forrunning clean supplies to computer equipment.

The double shield is effective at reducing both radiated and induced interference. The class 5 flexibleconductors ensure the cable can be easily routed even through confined spaces.

Originally developed for military use, these cables are now widely used within industry. They offer compact sizing, highworking voltage and a large range of sizes to suit most applications.

A robust and economical choice which can also be oversheathed or armoured for duct installation or direct burial. Thesecables should not be used as mains connection cables. Applications include data processing, information transfer, processcontrol and security as well as many industrial applications.

Def-Standard PVC Multicore

Construction

Unscreened type 'A' has fine tinned copper wire strands, colour coded PVC insulation, cores twisted together, PVC outer sheath.

Screened type 'C' has an overall polyester tape with tinned copper wire braid screen.

Screened type 'S' has an overall aluminium/polyester foil screen and tinned copper drain wire.

Individually Screened type 'D' has a tinned copper wire braid screen around each core.

Duct grade versions have a heavy duty black LDPE sheath over the standard PVC sheath.

Type ‘R’ uses 37 x 0.315mm stranding (2.9mm2) and has a overall tinned copper wire braid like type C.

Normally packed on 100m, 500m or 1000m spools, cables can also be cut to length when required.

For colour codes up to 36 cores see page 167.

Part No. Size No. of Cores Weight kg/km O/D mm

Unscreened 7/0.1mm - 0.055mm2

39200102 7-1-2A 2 7 2.539200103 7-1-3A 3 8 2.639200104 7-1-4A 4 10 2.839200106 7-1-6A 6 14 3.339200109 7-1-9A 9 18 3.939200112 7-1-12A 12 24 4.339200115 7-1-15A 15 27 4.539200118 7-1-18A 18 32 5.439200125 7-1-25A 25 42 5.839200136 7-1-36A 36 63 6.439200150 7-1-50A 50 76 7.3

Braid Screen 7/0.1mm - 0.055mm2

39300102 7-1-2C 2 9 3.039300103 7-1-3C 3 11 3.239300104 7-1-4C 4 17 3.439300106 7-1-6C 6 22 3.839300108 7-1-8C 8 25 4.239300109 7-1-9C 9 27 4.439300112 7-1-12C 12 44 4.639300115 7-1-15C 15 46 5.439300118 7-1-18C 18 54 5.839300125 7-1-25C 25 64 6.639300136 7-1-36C 36 83 7.239300150 7-1-50C 50 114 8.3

Unscreened 7/0.2mm - 0.22mm2

39200202 7-2-2A 2 14 3.439200203 7-2-3A 3 17 3.539200204 7-2-4A 4 22 3.839200206 7-2-6A 6 32 4.839200208 7-2-8A 8 47 5.639200212 7-2-12A 12 56 6.439200218 7-2-18A 18 82 7.439200220 7-2-20A 20 90 7.839200225 7-2-25A 25 100 8.739200236 7-2-36A 36 146 9.8

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

88 SIGNAL & CONTROL Def-Standard PVC

39300212

39400508

Part No. Size No. of Weight O/D Cores kg/km mm

Unscreened Duct 7/0.2mm - 0.22mm2

39200206D 7-2-6A 6 52 6.8

39200208D 7-2-8A 8 56 7.1

39200212D 7-2-12A 12 68 8.4

Foil Screened Duct 7/0.2mm - 0.22mm2

39400206D 7-2-6S 6 53 7.1

39400208D 7-2-8S 8 58 7.6

39400212D 7-2-12S 12 72 9.0

Braid Screen 7/0.2mm - 0.22mm2

39300202 7-2-2C 2 25 3.8

39300203 7-2-3C 3 29 4.0

39300204 7-2-4C 4 33 4.3

39300206 7-2-6C 6 57 5.6

39300208 7-2-8C 8 66 6.2

39300212 7-2-12C 12 87 6.9

39300215 7-2-15C 15 105 7.6

39300218 7-2-18C 18 115 8.4

39300220 7-2-20C 20 124 8.6

39300225 7-2-25C 25 153 9.5

39300236 7-2-36C 36 207 10.7

Foil Screened 7/0.2mm - 0.22mm2

39400202 7-2-2S 2 23 3.7

39400203 7-2-3S 3 28 4.0

39400204 7-2-4S 4 31 4.1

39400206 7-2-6S 6 52 4.8

39400208 7-2-8S 8 60 5.7

39400212 7-2-12S 12 79 6.2

39400218 7-2-18S 18 103 7.9

39400225 7-2-25S 25 141 8.8

39400236 7-2-36S 36 175 10.5

Ind. Braid Screen Cores 7/0.2mm - 0.22mm2

39600202 7-2-2D 2 21 4.3

39600203 7-2-3D 3 28 4.6

39600204 7-2-4D 4 38 5.1

39600206 7-2-6D 6 56 6.0

39600212 7-2-12D 12 112 8.2

39600218 7-2-18D 18 151 9.5

Part No. Size No. of Weight O/D Cores kg/km mm

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

89Def-Standard PVC SIGNAL & CONTROL

Technical Information

Voltage Rating: 0.055mm2 250V rms up to 1600Hz0.22mm2,0.5mm2 & 2.9mm2 440V rms up to 1600Hz

Temperature Rating: 0°C to +70°C Bend Radius: Static 7.5 cable diameterCurrent Rating: 0.055mm2 0.25 amps 0.22mm2 1 amp 0.5mm2 2.5 ampsNominal Conductor Max. Resistance @ 20°C: 0.055mm2 348 Ohm/km 0.22mm2 92 Ohm/km 0.5mm2 40.1 Ohm/km

2.9mm2 6.79 Ohm/km

Unscreened 16/0.2mm - 0.5mm2

39200502 16-2-2A 2 35 5.5

39200503 16-2-3A 3 42 5.8

39200504 16-2-4A 4 54 6.3

39200506 16-2-6A 6 76 7.3

39200508 16-2-8A 8 88 8.6

39200512 16-2-12A 12 120 9.5

39200518 16-2-18A 18 180 11.0

39200525 16-2-25A 25 265 12.5

39200536 16-2-36A 36 341 14.1

Braid Screen 16/0.2mm - 0.5mm2

39300502 16-2-2C 2 71 6.5

39300503 16-2-3C 3 82 6.8

39300504 16-2-4C 4 97 7.3

39300506 16-2-6C 6 130 8.3

39300508 16-2-8C 8 152 8.8

39300512 16-2-12C 12 202 10.5

39300518 16-2-18C 18 270 12.0

39300525 16-2-25C 25 350 14.1

39300536 16-2-36C 36 475 16.1

Ind. Braid Screen Cores 16/0.2mm - 0.5mm2

39600504 16-2-4D 4 93 7.5

39600506 16-2-6D 6 121 8.8

39600507 16-2-7D 7 134 8.9

39600512 16-2-12D 12 188 11.1

Foil Screen Cored or Paired 16/0.2mm - 0.5mm2

39400501P 16-2-1PS 1 Pair 38 5.2

39400502P 16-2-2PS 2 Pair 79 7.9

39400502 16-2-2S 2 47 5.0

39400503 16-2-3S 3 56 6.0

39400504 16-2-4S 4 61 6.8

39400506 16-2-6S 6 75 7.6

39400508 16-2-8S 8 89 8.2

39400512 16-2-12S 12 132 9.7

39400518 16-2-18S 18 198 12.6

39400525 16-2-25S 25 269 14.0

39400536 16-2-36S 36 387 15.9

Braid Screen 37/0.315mm - 2.9mm2

39302902 37-3-2R 2 150 6.8

39302903 37-3-3R 3 200 10.5

39302904 37-3-4R 4 250 11.0

For installations that call for Low Smoke Halogen Free signal cables the Niltox range of LSHF miniature multicores are theideal solution. Manufactured in the style of the Def Style PVC multicores on pages 88-89, these cables are suitable for usein public buildings & sensitive areas as they contain no Halogen emitting compounds. Screened and unscreened optionsare held in stock. This cable is not suitable for direct connection to the mains.

Def-Standard LSHF Multicore

39200206H

Construction

Fine tinned copper wire strands, colour coded Low

Smoke Halogen Free insulation, cores laid-up with

a Low Smoke Halogen Free outer sheath. Screened type

'C' has a polyester tape with a tinned copper braid

screen. Screened type 'S' has an aluminium foil screen

and tinned copper drain wire.

Technical Information

Voltage Rating: 440V rms up to 1600Hz

Temperature Rating: 0ºC to +70ºC

Current Rating: 0.22mm2 1amp 0.5mm2 2.5amps

Nominal Conductor

Max. Resistance @ 20ºC: 0.22mm2 - 92 ohms per km

0.5mm2 - 40.1 ohms per km

Bending Radius: Static 7.5 x cable diameter.

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Part No. Size No. of Weight O/D Cores kg/km mm

LSHF Unscreened 7/0.2mm - 0.22mm2

39200202H 7-2-2A 2 14 3.4

39200203H 7-2-3A 3 17 3.5

39200204H 7-2-4A 4 22 3.8

39200206H 7-2-6A 6 32 4.8

39200208H 7-2-8A 8 47 5.6

39200212H 7-2-12A 12 56 6.4

39200218H 7-2-18A 18 82 7.4

39200225H 7-2-25A 25 100 8.7

39200236H 7-2-36A 36 146 9.8

LSHF Braided Screened 7/0.2mm - 0.22mm2

39300202H 7-2-2C 2 25 3.8

39300203H 7-2-3C 3 29 4.0

39300204H 7-2-4C 4 33 4.3

39300206H 7-2-6C 6 57 5.6

39300208H 7-2-8C 8 66 6.2

39300212H 7-2-12C 12 87 6.9

39300218H 7-2-18C 18 115 8.4

39300225H 7-2-25C 25 153 9.5

39300236H 7-2-36C 36 207 10.7

LSHF Foil Screened 7/0.2mm - 0.22mm2

39400202H 7-2-2S 2 23 3.7

39400203H 7-2-3S 3 28 4.0

39400204H 7-2-4S 4 31 4.1

39400206H 7-2-6S 6 52 4.8

39400208H 7-2-8S 8 60 5.7

39400212H 7-2-12S 12 79 6.2

39400218H 7-2-18S 18 103 7.9

39400225H 7-2-25S 25 141 8.8

Part No. Size No. of Weight O/D Cores kg/km mm

LSHF Unscreened 16/0.2mm - 0.5mm2

39200502H 16-2-2A 2 35 5.5

39200503H 16-2-3A 3 42 5.8

39200504H 16-2-4A 4 54 6.3

39200506H 16-2-6A 6 76 7.3

39200508H 16-2-8A 8 96 8.6

39200512H 16-2-12A 12 120 9.5

39200518H 16-2-18A 18 180 11.0

39200525H 16-2-25A 25 274 14.1

LSHF Braided Screened 16/0.2mm - 0.5mm2

39300502H 16-2-2C 2 71 6.5

39300503H 16-2-3C 3 82 6.8

39300504H 16-2-4C 4 97 7.3

39300506H 16-2-6C 6 130 8.3

39300508H 16-2-8C 8 152 8.8

39300512H 16-2-12C 12 202 10.5

39300518H 16-2-18C 18 270 12.0

39300525H 16-2-25C 25 350 14.1

39300536H 16-2-36C 36 475 16.1

LSHF Foil Screened 16/0.2mm - 0.5mm2

39400501PH 16-2-1PS 1 Pair 47 5.2

39400502PH 16-2-2PS 2 Pair 68 7.6

39400502H 16-2-2S 2 47 5.0

39400503H 16-2-3S 3 56 6.0

39400504H 16-2-4S 4 61 6.8

39400506H 16-2-6S 6 75 7.6

39400508H 16-2-8S 8 89 8.2

39400512H 16-2-12S 12 132 9.7

39400518H 16-2-18S 18 198 12.6

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

90 SIGNAL & CONTROL Def-Standard LSHF

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

91SIGNAL & CONTROL Niltox® LF-316 LSHF

24916099

24901501

2491B and 6701B are flexible single cores with class 5 stranding conforming to the harmonisation standard H05Z-K andH07Z-K for Low Smoke Halogen Free single core cable. Applications include panel and conduit wiring where its flexibilitymakes installation easier.

Public and government buildings are increasingly using LSHF cabling to reduce the risk of injury through smoke inhalationin the event of a fire. The cables also produce less corrosive gases when burnt, which is particularly important wheresensitive electronic equipment is installed such as in computer rooms.

LF-249 H05Z-K & H07Z-K (2491B & 6701B)

Construction

Plain fine copper wire strands to IEC 60228class 5. Thermosetting insulation of Low SmokeHalogen Free compound to BS 7211.

BASEC approval available on many from stock. If required, please check at time of enquiry.

Technical Information

Voltage Rating: Up to 1.0mm2 300/500V

1.5mm2 and above 450/750V

Temperature Rating: -15°C to +90°C

Current Rating: 4E1A & B

Conductor Stranding: To IEC 60228 Class 5.

Manufactured to: BS 7211: 1994

Flame Retardant to: IEC 60332-1-2

Part No. Size No. of Strands/mm Weight kg/km O/D mm mm2

249005xx 0.5 16/0.20 10 2.1

249007xx 0.75 24/0.20 13 2.4

249010xx 1.0 32/0.20 16 2.5

249015xx 1.5 30/0.25 21 2.9

249025xx 2.5 50/0.25 33 3.6

249040xx 4.0 56/0.30 49 4.2

249060xx 6.0 84/0.30 70 5.0

249100xx 10 80/0.40 125 6.4

249160xx 16 126/0.40 180 8.0

249250xx 25 196/0.40 275 9.5

249350xx 35 276/0.40 380 11.7

249500xx 50 400/0.40 560 12.4

249700xx 70 356/0.50 780 14.5

249950xx 95 485/0.50 1000 17.0

249120xx 120 614/0.50 1300 17.7

249150xx 150 765/0.50 1600 19.5

249185xx 185 944/0.50 2000 22.0

249240xx 240 1225/0.50 2600 25.3

To show the colour required please replace xx in the part number with:

00 Black 04 White 08 Orange

01 Blue 05 Grey 09 Yellow

02 Brown 06 Violet 10 Green

03 Red 07 Pink 99 Green/Yellow

Standard pack size for conductor sizes up to and including 16mm2 is 100m, with some sizes/coloursstocked on 500m reels. 25mm2 and above is normally stocked on bulk reels and can be cut to thelength you require. Not all colours are available in the larger sizes.

11001504

Where mechanical protection is called for on a flexible cable, SY is a popular choice. The tough, flexible, clear outer sheathprovides excellent abrasion and oil resistance. Suitable as a supply or control cable for motors, plant, machinery and manyother applications.

SY PVC Steel Braided Multicore

Construction

Fine copper wire strands to IEC 60228 Class 5.

Black PVC insulation with white numbers or colour

coded. Cables with more than 2 cores include a

green/yellow earth, cores twisted together. Grey

PVC inner sheath, steel wire braid, clear PVC outer

sheath.

Technical Information

Voltage Rating: 300/500V Test 3000V

Temperature Rating: Static -20°C to +80°C

Flexing -5°C to +70°C

Bending Radius: Static 10 x cable diameter

Flexing 20 x cable diameter

Current Rating: Refer to IEE Regs Table 4F3A&B

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

11001502 2 x 1.5 102 8.511001503 3 x 1.5 122 8.711001504 4 x 1.5 146 9.311001505 5 x 1.5 158 9.911001507 7 x 1.5 214 12.411001512 12 x 1.5 321 13.711001518 18 x 1.5 464 16.811001525 25 x 1.5 625 19.811001542 42 x 1.5 959 23.4

11002502 2 x 2.5 152 9.811002503 3 x 2.5 169 10.111002504 4 x 2.5 212 10.911002505 5 x 2.5 223 11.811002507 7 x 2.5 295 13.011002512 12 x 2.5 499 17.311002518 18 x 2.5 685 19.8

11004003 3 x 4.0 241 11.711004004 4 x 4.0 286 12.611004005 5 x 4.0 342 13.911004007 7 x 4.0 460 15.7

11006003 3 x 6.0 354 14.111006004 4 x 6.0 397 14.811006005 5 x 6.0 496 16.911006007 7 x 6.0 613 18.4

11010004 4 x 10 638 18.211010005 5 x 10 766 19.811010007 7 x 10 979 22.2

11016004 4 x 16 996 21.811016005 5 x 16 1159 23.511025004 4 x 25 1383 25.311025005 5 x 25 1758 28.911035004 4 x 35 1938 29.711050004 4 x 50 2689 34.911070004 4 x 70 3583 44.811095004 4 x 95 4935 47.8

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

92 SIGNAL & CONTROL SY PVC

Number Coded

11000502 2 x 0.5 73 7.1

11000503 3 x 0.5 86 7.6

11000504 4 x 0.5 96 8.0

11000505 5 x 0.5 107 8.5

11000507 7 x 0.5 132 9.3

11000512 12 x 0.5 211 11.5

11000518 18 x 0.5 261 13.4

11000525 25 x 0.5 374 15.8

11000534 34 x 0.5 498 17.4

11000550 50 x 0.5 665 20.9

11000702 2 x 0.75 91 7.6

11000703 3 x 0.75 93 7.8

11000704 4 x 0.75 106 8.3

11000705 5 x 0.75 119 8.9

11000707 7 x 0.75 158 9.7

11000712 12 x 0.75 221 12.2

11000718 18 x 0.75 279 13.6

11000725 25 x 0.75 397 16.7

11000734 34 x 0.75 510 18.9

11000750 50 x 0.75 755 23.1

11001002 2 x 1.0 96 8.2

11001003 3 x 1.0 104 8.4

11001004 4 x 1.0 109 8.8

11001005 5 x 1.0 127 9.3

11001007 7 x 1.0 152 9.9

11001012 12 x 1.0 238 12.5

11001018 18 x 1.0 326 14.5

11001025 25 x 1.0 479 17.9

11001034 34 x 1.0 579 19.3

11001050 50 x 1.0 848 22.1

Part No. Cores x Weight O/Dmm² kg/km mm

Part No. Cores x Weight O/Dmm² kg/km mm

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

93SY PVC SIGNAL & CONTROL

Colour Coded

11000702C 2 x 0.75 91 7.6

11000703C 3 x 0.75 93 7.8

11000704E 4 x 0.75 106 8.3

11000705E 5 x 0.75 119 8.9

11000707C 7 x 0.75 181 12.6

11000712C 12 x 0.75 284 12.7

11001002C 2 x 1.0 96 8.2

11001003C 3 x 1.0 104 8.4

11001004E 4 x 1.0 109 8.8

11001005E 5 x 1.0 127 9.3

11001007E 7 x 1.0 342 10.8

11001012E 12 x 1.0 343 13.4

11001502C 2 x 1.5 102 8.5

11001503C 3 x 1.5 122 8.7

11001504E 4 x 1.5 146 9.3

11001505E 5 x 1.5 158 9.9

11001507C 7 x 1.5 286 12.7

11001512C 12 x 1.5 446 14.9

11002502C 2 x 2.5 152 9.8

11002503C 3 x 2.5 169 10.1

11002504E 4 x 2.5 212 10.9

11002505E 5 x 2.5 223 11.8

11002507C 7 x 2.5 427 15.4

11002512C 12 x 2.5 665 18.3

11004003C 3 x 4.0 241 11.7

11004004E 4 x 4.0 286 12.6

11004005E 5 x 4.0 342 13.9

11004007C 7 x 4.0 649 16.6

11006003C 3 x 6.0 549 14.7

11006004E 4 x 6.0 583 15.9

11006005E 5 x 6.0 674 17.4

11006007C 7 x 6.0 853 19.1

11010003C 3 x 10 744 18.2

11010004E 4 x 10 956 20.3

11010005E 5 x 10 1091 22.1

11016003C 3 x 16 1108 21.2

11016004E 4 x 16 1395 23.2

11016005E 5 x 16 1773 25.8

11025003C 3 x 25 1681 26.1

11025004E 4 x 25 2103 29.3

11025005E 5 x 25 2529 32.0

11035003C 3 x 35 1973 31.9

11035004E 4 x 35 2621 32.5

11035005E 5 x 35 3268 36.2

11050003C 3 x 50 2731 37.8

11050004E 4 x 50 3613 38.5

11050005E 5 x 50 4367 43.9

11070003C 3 x 70 2832 46.2

11070004E 4 x 70 4893 47.4

11070005E 5 x 70 5869 52.5

11095003C 3 x 95 4996 49.1

11095004E 4 x 95 6423 51.8

11095005E 5 x 95 8162 56.5

11120004E 4 x 120 8235 56.8

11150004E 4 x 150 10324 63.2

Blue Brown

Blue Brown Green/Yellow

Colour Code:

2 core

3 core

4 core

5 core

Blue Black Grey Green/Yellow

Blue Brown Black Grey Green/Yellow

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

94 SIGNAL & CONTROL CY PVC

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Protecting signals from electromagnetic interference (EMI) or reducing electromagnetic radiation (EMR) from supply cableshas substantially increased the need for screened multicore cables. Fine copper wire strands insulated with PVC and combinedwith pliable oil resistant PVC inner and outer sheaths ensure excellent flexibility, while the tinned copper wire braid formsan effective screen.

Clear white numbering on black cores enable fast ‘right first time’ termination, vital when working with large numbers ofcores or under artificial lighting which may distort core colours. CY has many uses including general wiring in machine toolapplications especially in conjunction with PLC or microprocessor controlled manufacturing operations where signalinterference could cause major problems.

Also used as a supply cable where circumstances result in power and data cables being run in close proximity to each other.In these cases EMR can be significantly reduced.

CY PVC Bedded Screened Multicore

Construction

Fine copper wire strands to IEC 60228 Class 5. Black PVC

insulation with white numbers, a green/yellow earth

conductor in cables with more than 2 cores. (Colour coded

versions also available). Cores twisted together. Grey PVC

inner sheath, tinned copper wire braid, clear PVC outer

sheath.

Technical Information

Voltage Rating: 300/500V Test 3000V

Temperature Rating: Static -20°C to +80°C

Flexing -5°C to +70°C

Bending Radius: Static 10 x cable diameter Flexing 20 x cable diameter

Current Rating: Refer to IEE Regs Table 4F3A&B

12001007

Part No. Cores x Weight O/Dmm² kg/km mm

12000502 2 x 0.5 91 6.8

12000503 3 x 0.5 102 7.4

12000504 4 x 0.5 114 7.9

12000505 5 x 0.5 126 8.6

12000507 7 x 0.5 155 9.2

12000512 12 x 0.5 213 11.6

12000518 18 x 0.5 338 13.4

12000525 25 x 0.5 406 15.5

12000702 2 x 0.75 102 7.2

12000703 3 x 0.75 118 7.7

12000704 4 x 0.75 134 8.3

12000705 5 x 0.75 158 8.9

12000707 7 x 0.75 183 9.7

12000712 12 x 0.75 263 12.1

12000718 18 x 0.75 393 15.3

12000725 25 x 0.75 544 16.8

12001002 2 x 1.0 117 7.6

12001003 3 x 1.0 134 8.1

12001004 4 x 1.0 154 8.6

12001005 5 x 1.0 182 9.7

12001007 7 x 1.0 202 10.5

12001012 12 x 1.0 346 13.4

12001018 18 x 1.0 476 15.6

12001025 25 x 1.0 644 18.1

12001041 41 x 1.0 1008 22.1

Part No. Cores x Weight O/Dmm² kg/km mm

12001502 2 x 1.5 142 8.6

12001503 3 x 1.5 165 9.1

12001504 4 x 1.5 189 10.1

12001505 5 x 1.5 223 10.6

12001507 7 x 1.5 268 11.5

12001512 12 x 1.5 441 15.1

12001518 18 x 1.5 626 17.4

12002503 3 x 2.5 214 10.4

12002504 4 x 2.5 258 11.3

12002505 5 x 2.5 306 12.9

12002507 7 x 2.5 422 13.9

12004004 4 x 4.0 411 13.5

12004005 5 x 4.0 482 14.8

12006004 4 x 6.0 533 15.9

12006005 5 x 6.0 657 17.4

12010004 4 x 10 932 19.1

12010005 5 x 10 1085 22.6

12016004E 4 x 16 1195 22.3

12025004E 4 x 25 1918 32.5

12035004E 4 x 35 2516 35.6

12050004E 4 x 50 3374 38.7

12070004E 4 x 70 3819 43.8

12095004E 4 x 95 5859 47.9

12120004E 4 x 120 7351 58.2

The FSC range of LSHF equipment wire is intended for use with electronic equipment within public buildings, controlpanels, higher temperature applications, military and commercial data processing, in fact anywhere where the safety ofpeople and property is essential.

Equipment Wire LSHF

Construction

Fine tinned copper wire strands, high performanceLSHF insulation.

Technical Information

Voltage Rating: 600V AC Test 3000V AC

Temperature Rating: -40°C to +120°C

Minimum Bending Radius: 6 x Overall Diameter

Part No. AWG Stranding CSA Weight O/D mm DC Resistance& mm mm2 kg/km @ 20°C (Ohms/km)

Resistant to some oils, fuels and acids. Please check at time of order if critical.

We are also able to offer LSHF equipment wire to Def-Stan 61-12 Part 18/5.

Versions that have both high (+200ºC) and lower (-60ºC) temperature ratings are also available.

To show the colour required please replace xx in the part number with:

00 Black 04 White 08 Orange

01 Blue 05 Grey 09 Yellow

02 Brown 06 Violet 10 Green

03 Red 07 Pink 99 Green/Yellow

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

95SIGNAL & CONTROL Equipment Wire LSHF

Equipment Wire

249E3007xx 30 7/0.10 0.057 0.9 0.70 355

249E2807xx 28 7/0.13 0.089 1.2 0.78 225

249E2619xx 26 19/0.10 0.155 1.9 0.88 135

249E2419xx 24 19/0.13 0.241 2.7 1.00 85.9

249E2219xx 22 19/0.16 0.382 4.0 1.16 53.1

249E2216xx - 16/0.20 0.50 5.2 1.28 40.1

249E2019xx 20 19/0.20 0.597 6.2 1.36 32.4

249E2024xx - 24/0.20 0.75 7.5 1.45 26.7

249E1819xx 18 19/0.25 0.963 9.5 1.60 20.4

249E1832xx - 32/0.20 1.00 9.5 1.60 20.0

249E1619xx 16 19/0.29 1.229 12.0 1.36 15.7

249E1630xx - 30/0.25 1.50 14.8 2.00 13.7

249E1419xx 14 19/0.36 1.870 18.5 2.21 10.0

249E1450xx - 50/0.25 2.50 24.0 2.45 8.21

249E1237xx 12 37/0.32 2.976 29.0 2.74 6.62

Designed for fixed installations where circuit integrity is critical in the event of a fire. The Low Smoke Halogen Freeinsulation also ensures minimal fumes and smoke are given off providing safety for both personnel and property.Maximum fire performance requires installation in either metal conduit or trunking.

Single Core Enhanced Circuit Integrity

Construction

Stranded plain copper conductor to IEC 60228 Class 2,

mica glass tape, LSHF insulation.

Technical Information

Voltage Rating: 0.6/1kV

Temperature Rating: -40ºC to +90ºC

Minimum Bending Radius: 8 x cable diameter

Flame Retardant: IEC 60332-1-2, IEC 60332-3-24C

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2, EN 50267-2-1

Fire Resistant: BS 6387 Categories CWZ

(when applied to a single cable

appropriately protected in steel conduit)3871600199

Some sizes and colours are also LPCB approved. If you need this please state at time of enquiry.

To show the colour required please replace xx in the part number with:

00 Black 04 White 08 Orange

01 Blue 05 Grey 09 Yellow

02 Brown 06 Violet 10 Green

03 Red 07 Pink 99 Green/Yellow

Part No. Size No. of Strands/mm Weight Maximum Conductor Resmm² kg/km O/D mm @ 20°C Ohms/km

3871501xx 1.5 7/0.53 33 3.9 12.10

3872501xx 2.5 7/0.67 43 4.6 7.41

3874001xx 4.0 7/0.85 56 5.2 4.61

3876001xx 6.0 7/1.04 87 5.7 3.08

38710001xx 10 7/1.35 150 7.3 1.83

38716001xx 16 7/1.70 201 8.2 1.15

38725001xx 25 7/2.14 323 9.9 0.727

38735001xx 35 7/2.52 415 10.8 0.524

38750001xx 50 19/1.78 553 13.4 0.387

38770001xx 70 19/2.14 776 15.3 0.268

38795001xx 95 19/2.52 1149 17.8 0.193

38712001xx 120 37/2.03 1426 19.3 0.153

38715001xx 150 37/2.25 1731 21.5 0.124

38718501xx 185 37/2.52 2158 23.8 0.0991

38724001xx 240 61/2.25 2931 26.8 0.0754

38730001xx 300 61/2.52 3549 29.8 0.0601

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

96 POWER Single Core Enhanced Circuit Integrity

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

97BS 5467 Armoured POWER

BS 5467 cables are used for mains or low voltage power and control circuits. They offer excellent mechanical protectionfrom damage through the use of a heavy galvanised steel wire armour. The GSWA armour and black UV stable waterresistant PVC jacket makes them suitable for use inside and outside buildings or for direct burial in the ground.

BS 5467 Armoured PVC Power Cables - 0.6/1kV

Construction

Plain copper conductors to IEC 60228 class 2 (stranded), XLPE

insulation, PVC inner sheath, galvanised steel wire armour,

PVC sheath – black.

Core Identification

2 Core Brown, blue

3 Core Brown, black, grey

4 Core Brown, black, grey, blue

5 Core Brown, black, grey, blue, green/yellow

7 Core and above, including all sizes of auxiliary cables - White

cores with black numbering

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: IEC 60228 class 2 shaped or circular

Temperature Rating: -15°C to +90°C max conductor

temperature

Bending Radius : 1.5mm² to 16mm²: 6 x overall diameter

Flame Retardant: IEC 60332-1-2

Manufactured To: BS 5467 / BS 60502

If a Low Smoke Halogen Free (LSHF) version is required please

use BS6724 which can be found on page 98.

A version with PVC insulation and PVC sheath is also available

as BS6436, please call for details.

54600103E

Part No. Cores x Weight kg/km Dia. over bedding O/D mm mm²

54600102E 2 x 1.5 305 7.7 12.354600103E 3 x 1.5 338 8.2 12.854600104E 4 x 1.5 381 8.9 13.554600105E 5 x 1.5 426 10.6 15.154600105AUX 5 x 1.5 426 10.6 15.154600107 7 x 1.5 490 10.9 15.954600202E 2 x 2.5 352 9.0 13.654600203E 3 x 2.5 397 9.5 14.154600204E 4 x 2.5 452 10.4 15.054600205E 5 x 2.5 549 12.5 17.154600205AUX 5 x 2.5 549 12.5 17.154600207 7 x 2.5 600 12.1 16.354600402E 2 x 4.0 419 10.1 14.754600403E 3 x 4.0 481 10.7 15.354600404E 4 x 4.0 563 11.8 16.454600405E 5 x 4.0 810 14.2 19.754600405AUX 5 x 4.0 810 14.2 19.754600407 7 x 4.0 950 13.9 19.754600602E 2 x 6.0 498 11.3 15.954600603E 3 x 6.0 569 11.5 16.654600604E 4 x 6.0 795 13.2 18.754600605E 5 x 6.0 865 14.0 19.654601002E 2 x 10* 764 13.2 18.054601003E 3 x 10* 869 13.9 20.054601004E 4 x 10* 1064 15.6 21.154601602E 2 x 16* 900 14.5 20.054601603E 3 x 16* 1159 15.8 22.054601604E 4 x 16* 1410 17.2 22.9

*Circular or compacted circular stranded conductors (class 2)Weights and dimensions will vary from manufacturer, if critical please check at time of order.Other conductor sizes and core counts available upon request

BS 6724 mains voltage armoured power and control cables are manufactured using Low Smoke Halogen Free compounds.This makes them ideal for use in public buildings, tunnels and areas of increased safety such as refineries and power stationswhere mechanical damage and fire risk is a concern.

BS 6724 Armoured LSHF Power – 0.6/1kV

Construction

Plain copper conductors to IEC 60228 class 2, XLPE insulation,

LSHF bedding, galvanised steel wire armour, black LSHF Sheath.

Core Identification

2 Core Brown, blue

3 Core Brown, black, grey

4 Core Brown, black, grey, blue

5 Core Brown, black, grey, blue, green/yellow

7 Core and above, including all sizes of auxiliary cables

White cores with black numbering

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

98 POWER BS 6724 Armoured LSHF

*Circular or compacted circular stranded conductors (class 2)Weights and dimensions will vary from manufacturer, if critical please check at time of order.Other conductor sizes and core counts are available upon request

Part No. Cores x Weight kg/km Dia. over bedding O/D mm mm²

72400102E 2 x 1.5 305 7.7 12.372400103E 3 x 1.5 338 8.2 12.872400104E 4 x 1.5 381 8.9 13.572400105E 5 x 1.5 426 10.6 15.172400105AUX 5 x 1.5 426 10.6 15.172400107 7 x 1.5 490 10.9 15.972400202E 2 x 2.5 352 9.0 13.672400203E 3 x 2.5 397 9.5 14.172400204E 4 x 2.5 452 10.4 15.072400205E 5 x 2.5 549 12.5 17.172400205AUX 5 x 2.5 549 12.5 17.172400207 7 x 2.5 600 12.1 16.372400402E 2 x 4.0 419 10.1 14.772400403E 3 x 4.0 481 10.7 15.372400404E 4 x 4.0 563 11.8 16.472400405E 5 x 4.0 810 14.2 19.772400405AUX 5 x 4.0 810 14.2 19.772400407 7 x 4.0 950 13.9 19.772400602E 2 x 6.0 498 11.3 15.972400603E 3 x 6.0 639 12.0 16.672400604E 4 x 6.0 795 13.2 18.772400605E 5 x 6.0 865 14.0 19.672401002E 2 x 10* 764 13.2 18.072401003E 3 x 10* 908 14.0 19.572401004E 4 x 10* 1064 15.6 21.172401005E 5 x 10* 1222 17.1 22.572401602E 2 x 16* 900 14.5 20.072401603E 3 x 16* 1220 15.5 21.272401604E 4 x 16* 1410 17.2 22.9

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: IEC 60228 class 2 shaped or circular

Temperature Rating: -15°C to +90°C maximum conductor

temperature

Bending Radius: 1.5mm² to 16mm²: 6 x overall diameter

Flame Retardant: IEC 60332-1-2, IEC 60332-3-24 cat C

Smoke Emission: IEC 61034-2, BS EN 50268

Halogen Emission: IEC 60754-2, BS EN 50267

Manufactured To: BS 6724 / IEC 60502

We are also able to supply fire resistant versions such as PrysmianFP 400, Draka Firetuf power and Nexans NX 400.Please specify sizes and quantity and if you require a specificmanufacturer.

72400604E

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

99Safe-T-Shield POWER

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Safe-T-Shield Low Smoke Halogen Free cable offers substantial advantages over conventional wiring methods. It is ideal forfixed wiring in hospitals, airports, computer rooms and other sensitive environments. The high level of screening ensuressubstantially reduced levels of electromagnetic interference (EMI) making it the right choice where electromagnetic capability(EMC) is a priority.

Safe-T-Shield is manufactured and tested to the performance criteria of BS 8436. Because it is faster to install and lighterthan small armoured cables or conduit, cost savings of up to 40% can be achieved. If the cable is pierced or accidentallycut the aluminium screen and CPC minimise the chance of personal injury.

This cable is an alternative to Multi-Plus and we are also able to supply Prysmian LSX® Brand.

Safe-T-Shield

Construction

Plain copper wire strands to IEC 60228 class 2, Halogen Free

XLPE insulation to BS 6899, full size tinned copper earth

conductor to IEC 60228 class 2, longitudinal aluminium tape,

Low Smoke Halogen Free sheath to BS EN 50267-2-1 & BS

EN 61034-2.

38802502E

Technical Information

Voltage Rating: 0.6/1kV

Temperature Rating: -10°C to +90°C

Sheath Colour: White, other colours on request

All cables have a full size bare earth or CPC.

Current Rating: Refer to IEE Regs table 4E2A

Flame Retardant: IEC 60332-1-2

Smoke Emission: IEC 61034-2

Halogen Emission: IEC 60754-1 & 2

Standard pack size 100m or 500m. Large sizes can be cut to the length required. Available in black in some sizes, please put B after the part number when ordering. A 300/500V grade, Safe-T-Shield Lite is also available.

Part No. Cores x Conductor Weight kg/km O/D mm mm² Stranding/mm

38801502E 2 E 1.5 7/0.53 105 9.8

38801503E 3 E 1.5 7/0.53 140 10.3

38801504E 4 E 1.5 7/0.53 160 11.2

38802502E 2 E 2.5 7/0.67 137 10.6

38802503E 3 E 2.5 7/0.67 184 11.1

38802504E 4 E 2.5 7/0.67 258 12.9

38804002E 2 E 4.0 7/0.85 209 11.3

38804003E 3 E 4.0 7/0.85 267 13.1

38804004E 4 E 4.0 7/0.85 320 14.2

38806002E 2 E 6.0 7/1.04 260 13.2

38806003E 3 E 6.0 7/1.04 330 14.2

38806004E 4 E 6.0 7/1.04 455 14.9

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

NYY cables are an economical solution to power and control wiring where mechanical protection is not required. Usedboth indoor and outdoor these cables are suitable for direct burial or through ducts, local regulations permitting. Originating in Germany they are now popular in many parts of the world where cost, weight and size savings through nothaving an armour can offer many benefits. They are also easy to gland and terminate and require less containment.

NYY: PVC/PVC Unarmoured Power – 0.6/1kV

Construction

Plain copper wire conductors to IEC 60228 class 1 or 2, PVC

insulation, bedding compound, PVC sheath – black.

Type NYY-J with protective earth NYY-O without protective earth

1 Core Green/yellow Black

2 Core - Brown, blue

3 Core Brown, blue, G/Y earth Brown, black, grey

4 Core Brown, black, grey, G/Y earth Brown, black, grey, blue

5 Core Brown, black, grey, blue, G/Y earth Black, blue, brown, grey, black

7 Core and above Number coded with a G/Y earth Number coded

Core Identification

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: ≤ 16 mm² solid. IEC 60228 class 1

Temperature Rating: -30°C to +70°C fixed

-5°C to +70°C for installation

Bending Radius: Single core 15 x overall diameter

Multi core 12 x overall diameter

Flame Retardant: VDE 0472 test B, IEC 60332-1-2,

EN 50265-2-1

Manufactured To: VDE 0276 pt 603 up to 5 core,

pt 627 for 7 core & above, IEC 60502

NYY can be supplied with a green/yellow earth conductor -

reference NYY-J or without an earth conductor – reference NYY-O.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

100 POWER NYY

Part No. Part No. Cores x Weight kg/km O/D mm NYY-J NYY-O mm²

- N0100102E 2 x 1.5 165 11.0

N0100103E N0100103 3 x 1.5 185 12.5

N0100104E N0100104 4 x 1.5 220 13.0

N0100105E N0100105 5 x 1.5 275 13.5

N0100107E N0100107 7 x 1.5 355 15.0

N0100110E N0100110 10 x 1.5 525 18.5

N0100112E N0100112 12 x 1.5 565 19.0

N0100114E N0100114 14 x 1.5 615 20.5

N0100116E N0100116 16 x 1.5 695 20.5

N0100119E N0100119 19 x 1.5 755 21.5

- N0100121 21 x 1.5 825 21.5

N0100124E N0100124 24 x 1.5 945 24.5

N0100130E N0100130 30 x 1.5 1105 25.5

N0100604E

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

101NYY POWER

Part No. Part No. Cores x Weight kg/km O/D mm NYY-J NYY-O mm²

- N0100202E 2 x 2.5 210 12.0

N0100203E N0100203 3 x 2.5 235 13.0

N0100204E N0100204 4 x 2.5 285 13.5

N0100205E N0100205 5 x 2.5 350 14.5

N0100207E - 7 x 2.5 445 16.0

N0100210E - 10 x 2.5 625 20.0

N0100212E - 12 x 2.5 675 20.5

N0100214E - 14 x 2.5 785 21.0

N0100216E - 16 x 2.5 865 22.5

N0100219E - 19 x 2.5 920 23.0

N0100221E - 21 x 2.5 1045 23.5

N0100224E - 24 x 2.5 1395 26.0

N0100230E - 30 x 2.5 1445 28.5

N0100401E N0100401 1 x 4.0 100 9.0

- N0100402E 2 x 4.0 295 14.0

N0100403E N0100403 3 x 4.0 325 16.0

N0100404E N0100404 4 x 4.0 395 17.0

N0100405E N0100405 5 x 4.0 475 18.0

N0100601E N0100601 1 x 6.0 125 9.5

- N0100602E 2 x 6.0 355 15.5

N0100603E N0100603 3 x 6.0 420 16.0

N0100604E N0100604 4 x 6.0 515 18.5

N0100605E N0100605 5 x 6.0 615 19.5

N0101001 N0101001 1 x 10 185 9.5

- N0101002E 2 x 10 490 16.5

N0101003 N0101003 3 x 10 585 18.0

N0101004 N0101004 4 x 10 725 20.0

N0101005 N0101005 5 x 10 885 21.5

N0101601E N0101601 1 x 16 245 10.0

- N0101602E 2 x 16 665 19.0

N0101603E N0101603 3 x 16 810 20.5

N0101604E N0101604 4 x 16 1055 22.0

N0101605E N0101605 5 x 16 1250 24.0

Larger sizes up to 630mm² can be supplied cut to length on short lead-times, please call us with yourspecific requirement.

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Originally designed for wiring ships, BS 6883 cables have been widely adopted in other marine installations including oil rigsand platforms. They are available in single and multi core versions both unarmoured (type 657 SW4) and with a galvanized steel wire braid armour (type 658 SW4) for mechanical protection.

Construction

657 SW4 Unarmoured

Tinned stranded copper conductor, EPR insulation, SW4 LSHF

elastomeric outer sheath – black.

658 SW4 Armoured

Tinned stranded copper conductor, EPR insulation, Halogen

Free elastomeric bedding, galvanized steel wire braid armour,

SW4 LSHF elastomeric outer sheath - black.

65702512H

BS 6883 0.6/1kV Shipwiring Power

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: IEC 60228 Class 2, tinned copper

Temperature Rating: -30°C to +85°C

Bending Radius Static: 657 SW4 658 SW4

≤ 10mm2 3 x cable OD 4 x cable OD

>10mm2 to 25mm2 4 x cable OD 4 x cable OD

> 25mm2 6 x cable OD 6 x cable OD

Oxygen Index of Sheath: >31%

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Manufactured To: BS 6883/UKOOA

Part No. Cores x Weight O/Dmm² kg/km mm

BS6883 657 SW4 Unarmoured 65701501H 1 x 1.5 42 6.065701502H 2 x 1.5 105 8.565701503H 3 x 1.5 130 9.065701504H 4 x 1.5 155 10.065701507H 7 x 1.5 260 12.065701512H 12 x 1.5 405 15.565701519H 19 x 1.5 590 19.065701527H 27 x 1.5 820 22.065702501H 1 x 2.5 57 6.065702502H 2 x 2.5 145 9.565702503H 3 x 2.5 180 10.065702504H 4 x 2.5 215 11.065702507H 7 x 2.5 365 13.065702512H 12 x 2.5 585 18.065702519H 19 x 2.5 860 21.0 65704001H 1 x 4.0 82 7.065704002H 2 x 4.0 225 11.565704003H 3 x 4.0 270 12.065704004H 4 x 4.0 355 13.065706001H 1 x 6.0 105 7.065706002H 2 x 6.0 285 13.065706003H 3 x 6.0 350 13.565706004H 4 x 6.0 445 14.565710001H 1 x 10 165 8.065710002H 2 x 10 445 14.565710003H 3 x 10 565 15.565710004H 4 x 10 700 17.0

Part No. Cores x Weight O/Dmm² kg/km mm

65716001H 1 x 16 230 9.5

65716002H 2 x 16 630 17.0

65716003H 3 x 16 795 18.0

65716004H 4 x 16 1010 20.0

65725001H 1 x 25 360 12.0

65725002H 2 x 25 965 21.0

65725003H 3 x 25 1240 22.0

65725004H 4 x 25 1570 25.5

65735001H 1 x 35 425 12.5

65735002H 2 x 35 1140 23.0

65735003H 3 x 35 1480 25.0

65735004H 4 x 35 1880 27.0

65750001H 1 x 50 570 14.0

65750002H 2 x 50 1520 26.0

65750003H 3 x 50 1960 28.5

65750004H 4 x 50 2510 32.0

65770001H 1 x 70 785 16.0

65770002H 2 x 70 2070 31.0

65770003H 3 x 70 2700 33.0

65770004H 4 x 70 3490 36.0

65795001H 1 x 95 1060 18.0

65795003H 3 x 95 3680 37.0

65795004H 4 x 95 4780 42.0

65712001H 1 x 120 1300 21.0

65712003H 3 x 120 4490 42.0

65712004H 4 x 120 5830 46.0

Core Identification

White cores with black numbers. Colour coded cores available to order.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

102 MOG BS 6883 0.6/1kV Shipwiring Power

65802512H

Part No. Cores x mm² Weight kg/km Dia. over Bedding mm O/D mm

BS6883 658 SW4 Armoured65801502H 2 x 1.5 280 10.0 13.565801503H 3 x 1.5 310 10.5 14.565801504H 4 x 1.5 390 11.5 16.565801507H 7 x 1.5 570 14.0 18.065801512H 12 x 1.5 780 18.5 23.565801519H 19 x 1.5 1080 22.0 27.565801527H 27 x 1.5 1430 26.5 32.065802502H 2 x 2.5 320 11.0 14.565802503H 3 x 2.5 400 11.5 16.065802504H 4 x 2.5 460 12.5 17.065802507H 7 x 2.5 650 15.0 20.065802512H 12 x 2.5 980 20.0 25.065802519H 19 x 2.5 1350 24.0 29.065802527H 27 x 2.5 1810 29.5 34.565804002H 2 x 4.0 420 12.0 16.565804003H 3 x 4.0 505 13.0 17.065804004H 4 x 4.0 590 14.0 19.065806002H 2 x 6.0 510 13.0 18.065806003H 3 x 6.0 595 14.0 18.565806004H 4 x 6.0 700 15.5 20.065810002H 2 x 10 680 15.0 20.065810003H 3 x 10 780 16.0 20.565810004H 4 x 10 935 18.0 23.065816002H 2 x 16 960 17.5 23.065816003H 3 x 16 1120 18.5 24.065816004H 4 x 16 1370 20.5 26.065825002H 2 x 25 1250 21.0 26.065825003H 3 x 25 1500 22.5 27.565825004H 4 x 25 1850 25.0 30.065835002H 2 x 35 1455 23.5 28.065835003H 3 x 35 1950 25.0 30.065835004H 4 x 35 2380 28.0 33.565850002H 2 x 50 2160 27.0 32.565850003H 3 x 50 2640 29.0 34.065850004H 4 x 50 3300 32.5 38.565870002H 2 x 70 2930 31.0 37.065870003H 3 x 70 3630 33.0 39.065870004H 4 x 70 4340 37.0 43.065895003H 3 x 95 4720 38.0 44.065895004H 4 x 95 5830 42.5 49.065812003H 3 x 120 5820 41.0 48.565812004H 4 x 120 7180 46.0 54.0

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

103BS 6883 0.6/1kV Shipwiring Power MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Manufactured in both pairs and triples these 150/250V marine instrumentation cables provide collective or individualscreening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or wheredifficult routing is necessary these cables are ideal where no additional mechanical protection is required. Using SW4 LowSmoke Halogen Free sheathing compounds ensures that in the event of a fire the cable offers excellent protection to bothpeople and property by not emitting toxic or corrosive gases.

Construction

Collectively Screened

Tinned copper wire conductors to IEC 60228 class 2, EPR

insulation, cores twisted into pairs or triples, overall foil screen

and drain wire, SW4 oil resistant LSHF sheath - grey, blue or

black.

Individually Screened

Tinned copper wire conductors to IEC 60228 class 2, EPR

insulation, cores twisted into pairs or triples, each pair or

triple aluminum foil screened with a drain wire, SW4 oil

resistant LSHF sheath – grey, blue or black.

Class 5 conductors to IEC 60228 can be supplied on request.

BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation

Electrical Characteristics

Conductor Size: 0.75mm² 1.5mm²

Conductor Resistance: <24.5 Ohms/km <12.1 Ohms/km

Insulation Resistance: 940 MOhm x km 730 MOhm x km

Mutual Capacitance @ 800Hz:

Individual Screen: 90nF/km 110nF/km

Collective Screen: 80nF/km 90nF/km

Technical Information

Voltage Rating: 150/250V

Conductor Stranding: IEC 60228 Class 2,

tinned copper conductors

Temperature Rating: -30°C to +85°C

Bending Radius Static: 8 x overall diameter

Oxygen Index of Sheath: >31%

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A,

BS 4066-3

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Oil Resistant: BS 7655 SW4 section 2.6

Manufactured To: BS 6883/UKOOA

Core Identification

Pairs - Black & white

Triples - Black, white & red

Each pair is identified by a numbered tape or printed

numbers on the cores.

Part No. No. of Pairs mm2 Weight kg/km O/D mm

Pairs Collectively Screened657C0702PHxx 2 0.75 180 12.5657C0703PHxx 3 0.75 210 13.0657C0707PHxx 7 0.75 380 18.0657C0712PHxx 12 0.75 610 23.5657C0719PHxx 19 0.75 875 27.0657C0720PHxx 20 0.75 975 28.5657C0727PHxx 27 0.75 1210 32.5

657C1502PHxx 2 1.5 271 14.0657C1503PHxx 3 1.5 310 15.8657C1507PHxx 7 1.5 601 20.0657C1512PHxx 12 1.5 900 26.0657C1520PHxx 20 1.5 1310 30.5657C1527PHxx 27 1.5 1780 32.5

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

104 MOG BS 6883 657-SW4 Shipwiring Instrumentation

657C0707PH00

To show the colour required please replace xx in the part number with:

05 Grey 01 Blue 00 Black

Other pair and triple configurations available on request

Part No. No. of Pairs mm2 Weight kg/km O/D mm

Pairs Individually Screened657I0701PHxx 1 0.75 95 8.1657I0702PHxx 2 0.75 165 12.0657I0703PHxx 3 0.75 260 13.0657I0707PHxx 7 0.75 480 18.5657I0712PHxx 12 0.75 750 22.5657I0720PHxx 20 0.75 1150 28.0657I0727PHxx 27 0.75 1600 31.5

658I1501PHxx 1 1.5 135 16.5658I1502PHxx 2 1.5 254 14.3657I1503PHxx 3 1.5 300 15.0657I1507PHxx 7 1.5 690 21.0657I1512PHxx 12 1.5 1110 27.0657I1520PHxx 20 1.5 1850 34.5

Part No. No. of Triples mm2 Weight kg/km O/D mm

Triples Collectively Screened657C0703THxx 3 0.75 260 15.0657C0707THxx 7 0.75 501 20.5657C0712THxx 12 0.75 805 25.0

657C1503THxx 3 1.5 350 15.5657C1507THxx 7 1.5 790 23.4657C1512THxx 12 1.5 1250 28.5

Triples Individually Screened657I0701THxx 1 0.75 110 8.5657I0703THxx 3 0.75 300 15.0657I0707THxx 7 0.75 580 19.5657I0712THxx 12 0.75 971 25.0

657I1501THxx 1 1.5 165 9.5657I1503THxx 3 1.5 410 17.5657I1507THxx 7 1.5 900 25.0657I1512THxx 12 1.5 1500 28.5

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

105BS 6883 657-SW4 Shipwiring Instrumentation MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Similar in construction to the BS 6883 657 SW4 instrumentation types, these cables have an additional steel wire braidarmour for mechanical protection. Manufactured in both pairs and triples these 150/250V marine instrumentation cablesprovide collective or individual screening through the use of metallic foils and drain wires. They maintain good flexibility forinstallation on ships and oil rigs. The SW4 Low Smoke Halogen Free sheathing is oil resistant and ensures that in the eventof a fire the cable will offer excellent protection to both people and property by not emitting toxic or corrosive gases.

Construction

Collectively Screened

Tinned copper wire conductors to IEC 60228 class 2, EPR

insulation, cores twisted into pairs or triples, overall foil screen

and drain wire, LSHF bedding, galvanised steel wire braid,

SW4 oil resistant LSHF sheath - grey, blue or black.

Class 5 conductors to IEC 60228 can be supplied on request.

Individually Screened

Tinned copper wire conductors to IEC 60228 class 2, EPR

insulation, cores twisted into pairs or triples, each pair or

triple aluminum foil screened with a drain wire, LSHF

bedding, galvanised steel wire braid, SW4 oil resistant LSHF

sheath – grey, blue or black.

Part No. No. of Pairs Size mm² Weight kg/km Dia. over Bedding mm O/D mm

Pairs Collectively Screened658C0702PHxx 2 0.75 379 13.5 15.5658C0703PHxx 3 0.75 420 12.0 16.5658C0707PHxx 7 0.75 660 16.5 21.0658C0712PHxx 12 0.75 1010 21.5 26.0658C0719PHxx 19 0.75 1460 24.5 29.5658C0720PHxx 20 0.75 1570 25.5 31.5658C0727PHxx 27 0.75 1980 29.0 35.5

658C1502PHxx 2 1.5 477 14.0 17.5658C1503PHxx 3 1.5 520 15.0 18.5658C1507PHxx 7 1.5 821 18.5 23.0658C1512PHxx 12 1.5 1291 24.5 30.0658C1520PHxx 20 1.5 2130 29.0 35.5658C1527PHxx 27 1.5 2650 33.5 40.0

BS 6883 658-SW4 Armoured Shipwiring Instrumentation

Electrical Characteristics

Conductor Size: 0.75mm² 1.5mm²

Conductor Resistance: <24.5 Ohms/km <12.1 Ohms/km

Insulation Resistance: 940 MOhm x km 730 MOhm x km

Mutual Capacitance @ 800Hz:

Individual Screen: 90nF/km 110nF/km

Collective Screen: 80nF/km 90nF/km

Technical Information

Voltage Rating: 150/250V

Conductor Stranding: IEC 60228 Class 2,

tinned copper conductors

Temperature Rating: -30°C to +85°C

Bending Radius Static: 8 x overall diameter

Oxygen Index of Sheath: >31%

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Oil Resistant: BS 7655 SW4 section 2.6

Manufactured To: BS 6883/UKOOA

Core Identification

Pairs - Black & white

Triples - Black, white & red

Each pair is identified by a numbered tape or printed

numbers on the cores.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

106 MOG BS 6883 658-SW4 Shipwiring Instrumentation

658C0707PH05

Part No. No. of Pairs Size mm² Weight kg/km Dia. over Bedding mm O/D mm

Pairs Individually Screened658I0701PHxx 1 0.75 230 7.5 11.5658I0702PHxx 2 0.75 420 11.0 17.0658I0703PHxx 3 0.75 530 12.0 18.5658I0707PHxx 7 0.75 721 16.5 21.0658I0712PHxx 12 0.75 1111 22.0 27.0658I0720PHxx 20 0.75 1701 26.0 34.5

658I1501PHxx 1 1.5 290 8.5 12.5658I1502PHxx 2 1.5 511 13.0 18.0658I1503PHxx 3 1.5 560 14.0 19.0658I1507PHxx 7 1.5 980 20.0 26.0658I1512PHxx 12 1.5 1670 25.0 32.0658I1520PHxx 20 1.5 2430 31.5 38.0

Part No. No. of Triples Size mm² Weight kg/km Dia. over Bedding mm O/D mm

Triples Collectively Screened658C0703THxx 3 0.75 510 13.5 18.0658C0707THxx 7 0.75 820 18.0 22.5658C0712THxx 12 0.75 1290 24.0 29.0

658C1503THxx 3 1.5 520 14.5 19.5658C1507THxx 7 1.5 1280 20.5 26.5658C1512THxx 12 1.5 1840 27.5 33.5

Triples Individually Screened658I0701THxx 1 0.75 245 8.0 12.0658I0703THxx 3 0.75 530 14.0 18.5658I0707THxx 7 0.75 898 18.5 23.5658I0712THxx 12 0.75 1530 25.0 31.0

658I1501THxx 1 1.5 320 9.0 13.0658I1503THxx 3 1.5 690 15.5 20.5658I1507THxx 7 1.5 1390 23.0 27.5658I1512THxx 12 1.5 2105 29.5 34.5

To show the colour required please replace xx in the part number with:

05 Grey 01 Blue 00 Black

Other pair and triple configurations available on request

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

107BS 6883 658-SW4 Shipwiring Instrumentation MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Used widely on ships, oil rigs, platforms and refineries where fire resistance to IEC 60331 is vital. BS 7917 cables providecircuit integrity to maintain essential services in the event of a fire.

The 657M SW4 unarmoured versions are ideal for applications where small bending radii are required. When mechanicalprotection is needed the 658M SW4 steel braid armour (GSWB) version provides the solution whilst maintaining goodflexibility for installation in restricted areas.

BS 7917 0.6/1kV Shipwiring Power – Fire Resistant

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: IEC 60228 Class 2, tinned copper

Temperature Rating: -30°C to +85°C

Bending Radius Static: 657M SW4 658M SW4

≤ 10mm2 3 x cable OD 4 x cable OD

>10mm2 to 25mm2 4 x cable OD 4 x cable OD

> 25mm2 6 x cable OD 6 x cable OD

Oxygen Index of Sheath: >31%

Fire Resistant: IEC 60331-21

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Manufactured To: BS 7917 / BS 6883

Core Identification

White cores with black numbers. Colour coded cores available to order.

65701512HM

Part No. Cores x Weight O/Dmm² kg/km mm

BS 7917 657M SW4 Unarmoured

65701501HM 1 x 1.5 42 6.0

65701502HM 2 x 1.5 105 8.5

65701503HM 3 x 1.5 130 9.0

65701504HM 4 x 1.5 155 10.0

65701507HM 7 x 1.5 260 12.0

65701512HM 12 x 1.5 405 15.5

65701519HM 19 x 1.5 590 19.0

65701527HM 27 x 1.5 820 22.0

65702501HM 1 x 2.5 57 6.0

65702502HM 2 x 2.5 145 9.5

65702503HM 3 x 2.5 180 10.0

65702504HM 4 x 2.5 215 11.0

65702507HM 7 x 2.5 365 13.0

65702512HM 12 x 2.5 585 18.0

65702519HM 19 x 2.5 860 21.0

65704001HM 1 x 4.0 82 7.0

65704002HM 2 x 4.0 225 11.5

65704003HM 3 x 4.0 270 12.0

65704004HM 4 x 4.0 355 13.0

65706001HM 1 x 6.0 105 7.0

65706002HM 2 x 6.0 285 13.0

Part No. Cores x Weight O/Dmm² kg/km mm

65706003HM 3 x 6.0 350 13.5

65706004HM 4 x 6.0 445 14.5

65710001HM 1 x 10 165 8.0

65710002HM 2 x 10 445 14.5

65710003HM 3 x 10 565 15.5

65710004HM 4 x 10 700 17.0

65716001HM 1 x 16 230 9.5

65716002HM 2 x 16 630 17.0

65716003HM 3 x 16 795 18.0

65716004HM 4 x 16 1010 20.0

65725001HM 1 x 25 360 12.0

65725002HM 2 x 25 965 21.0

65725003HM 3 x 25 1240 22.0

65725004HM 4 x 25 1570 25.5

65735001HM 1 x 35 425 12.5

65735002HM 2 x 35 1140 23.0

65735003HM 3 x 35 1480 25.0

65735004HM 4 x 35 1880 27.0

65750001HM 1 x 50 570 14.0

65750002HM 2 x 50 1520 26.0

65750003HM 3 x 50 1960 28.5

65750004HM 4 x 50 2510 32.0

Construction

657M SW4 Unarmoured

Stranded tinned copper conductor, mica glass tape fire barrier,

EPR insulation, SW4 LSHF elastomeric outer sheath – black.

Single core cables are available in green/yellow for earthing

applications.

658M SW4 Armoured

Stranded tinned copper conductor, mica glass tape fire barrier,

EPR insulation, halogen free thermoplastic elastomeric bedding,

galvanized steel wire braid armour,

SW4 LSHF elastomeric outer sheath - black.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

108 MOG BS 7917 0.6/1kV Shipwiring Power

Part No. Cores x Weight O/Dmm² kg/km mm

65770001HM 1 x 70 785 16.065770002HM 2 x 70 2070 31.065770003HM 3 x 70 2700 33.065770004HM 4 x 70 3490 36.065795001HM 1 x 95 1060 18.0

Part No. Cores x Weight O/Dmm² kg/km mm

65795003HM 3 x 95 3680 37.065795004HM 4 x 95 4780 42.065712001HM 1 x 120 1300 21.065712003HM 3 x 120 4490 42.065712004HM 4 x 120 5830 46.0

Part No. Cores x mm² Weight kg/km Dia. over Bedding mm O/D mm

BS 7917 658M SW4 Armoured 65801502HM 2 x 1.5 280 10.0 13.565801503HM 3 x 1.5 310 10.5 14.565801504HM 4 x 1.5 390 11.5 16.565801507HM 7 x 1.5 570 14.0 18.065801512HM 12 x 1.5 780 18.5 23.565801519HM 19 x 1.5 1080 22.0 27.565801527HM 27 x 1.5 1430 26.5 32.065802502HM 2 x 2.5 320 11.0 14.565802503HM 3 x 2.5 400 11.5 16.065802504HM 4 x 2.5 460 12.5 17.065802507HM 7 x 2.5 650 15.0 20.065802512HM 12 x 2.5 980 20.0 25.065802519HM 19 x 2.5 1350 24.0 29.065802527HM 27 x 2.5 1810 29.5 34.565804002HM 2 x 4.0 420 12.0 16.565804003HM 3 x 4.0 505 13.0 17.065804004HM 4 x 4.0 590 14.0 19.065806002HM 2 x 6.0 510 13.0 18.065806003HM 3 x 6.0 595 14.0 18.565806004HM 4 x 6.0 700 15.5 20.065810002HM 2 x 10 680 15.0 20.065810003HM 3 x 10 780 16.0 20.565810004HM 4 x 10 935 18.0 23.065816002HM 2 x 16 960 17.5 23.065816003HM 3 x 16 1120 18.5 24.065816004HM 4 x 16 1370 20.5 26.065825002HM 2 x 25 1250 21.0 26.065825003HM 3 x 25 1500 22.5 27.565825004HM 4 x 25 1850 25.0 30.065835002HM 2 x 35 1455 23.5 28.065835003HM 3 x 35 1950 25.0 30.065835004HM 4 x 35 2380 28.0 33.565850002HM 2 x 50 2160 27.0 32.565850003HM 3 x 50 2640 29.0 34.065850004HM 4 x 50 3300 32.5 38.565870002HM 2 x 70 2930 31.0 37.065870003HM 3 x 70 3630 33.0 39.065870004HM 4 x 70 4340 37.0 43.065895003HM 3 x 95 4720 38.0 44.065895004HM 4 x 95 5830 42.5 49.065812003HM 3 x 120 5820 41.0 48.565812004HM 4 x 120 7180 46.0 54.0

For green/yellow single cores suffix the part code "E"

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

109BS 7917 0.6/1kV Shipwiring Power MOG

65801512HM

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Fire resistant instrumentation cables provide collective or individual screening through the use of metallic foils and drainwires. Mica glass tape fire barriers provide circuit integrity whilst the oil resistant SW4 Low Smoke Halogen Free sheathingcompound ensures protection to both people and property during a fire.

BS 7917 657M-SW4 Fire Resistant Unarmoured Shipwiring Instrumentation

Electrical Characteristics

Conductor Size: 0.75mm² 1.5mm²

Conductor Resistance: <24.5 Ohms/km <12.1 Ohms/km

Insulation Resistance: 940 MOhm x km 730 MOhm x km

Mutual Capacitance @ 800Hz:

Collective Screen: 80nF/km 90nF/km

Individual Screen: 90nF/km 110nF/km

Construction

Collectively Screened

Tinned copper wire conductors to IEC 60228 class 2, mica

glass tape fire barrier EPR insulation, cores twisted into pairs

or triples, overall foil screen and drain wire, SW4 oil resistant

LSHF sheath - grey, blue or black.

Individually Screened

Tinned copper wire conductors to IEC 60228 class 2, mica glass

tape fire barrier, EPR insulation, cores twisted into pairs or

triples, each pair or triple aluminum foil screened with a drain

wire, SW4 oil resistant LSHF sheath – grey, blue or black.

Class 5 conductors to IEC 60228 can be supplied on request.

Technical Information

Voltage Rating: 150/250V

Conductor Stranding: IEC 60228 Class 2, tinned copper

Temperature Rating: -30°C to +85°C

Bending Radius Static: 8 x overall diameter

Oxygen Index of Sheath: >31%

Fire Resistant: IEC 60331-21

Flame Retardant: IEC 60332-1-2,

IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Oil Resistant: BS 7655 SW4 section 2.6

Manufactured To: BS 7917/UKOOA

Core Identification

Pairs - Black & white

Triples - Black, white & red

Each pair is identified by a numbered tape or printed numbers

on the cores.

Part No. No. of Pairs mm² Weight kg/km O/D mm

Pairs Collectively Screened657C0702PHMxx 2 0.75 180 12.5657C0703PHMxx 3 0.75 230 14.0657C0707PHMxx 7 0.75 410 19.0657C0712PHMxx 12 0.75 620 24.5657C0719PHMxx 19 0.75 900 28.5657C0720PHMxx 20 0.75 990 30.0657C0727PHMxx 27 0.75 1290 33.0

657C1502PHMxx 2 1.5 271 14.0657C1503PHMxx 3 1.5 410 16.5657C1507PHMxx 7 1.5 680 21.0657C1512PHMxx 12 1.5 1050 27.5657C1520PHMxx 20 1.5 1480 31.5657C1527PHMxx 27 1.5 1860 33.0

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

110 MOG BS 7917 657M-SW4 Shipwiring Instrumentation

657C0707PHM00

Part No. No. of Triples mm² Weight kg/km O/D mm

Triples Collectively Screened657C0703THMxx 3 0.75 280 16.0657C0707THMxx 7 0.75 530 22.0657C0712THMxx 12 0.75 820 26.5

657C1503THMxx 3 1.5 375 16.5657C1507THMxx 7 1.5 815 24.8657C1512THMxx 12 1.5 1300 30.0

Triples Individually Screened657I0701THMxx 1 0.75 135 10.0657I0703THMxx 3 0.75 325 16.5657I0707THMxx 7 0.75 595 21.0657I0712THMxx 12 0.75 990 26.0

657I1501THMxx 1 1.5 187 11.0657I1503THMxx 3 1.5 450 18.5657I1507THMxx 7 1.5 960 26.0657I1512THMxx 12 1.5 1610 30.5

To show the colour required please replace xx in the part number with:

05 Grey 01 Blue 00 Black

Other pair and triple configurations available on request

Part No. No. of Pairs mm² Weight kg/km O/D mm

Pairs Individually Screened657I0701PHMxx 1 0.75 120 9.5657I0702PHMxx 2 0.75 165 12.0657I0703PHMxx 3 0.75 280 14.0657I0707PHMxx 7 0.75 510 19.5657I0712PHMxx 12 0.75 850 23.5657I0720PHMxx 20 0.75 1300 29.0657I0727PHMxx 27 0.75 1710 33.0

658I1501PHMxx 1 1.5 145 17.5658I1502PHMxx 2 1.5 254 14.3657I1503PHMxx 3 1.5 350 16.5657I1507PHMxx 7 1.5 760 23.0657I1512PHMxx 12 1.5 1210 29.0657I1520PHMxx 20 1.5 1990 35.5

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

111BS 7917 657M-SW4 Shipwiring Instrumentation MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Manufactured with a galvanised steel wire braid for mechanical protection these fire resistant cables are available in both pairsand triples to provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibilityand circuit integrity their use has spread from ships to rigs and many onshore/offshore applications.

The oil resistant SW4 Low Smoke Halogen Free sheathing compounds ensure that in the event of a fire the cables offer excellentprotection to both people and property by not emitting toxic or corrosive gases whilst keeping emergency circuits operating.

BS 7917 658M-SW4 Fire Resistant Armoured Shipwiring Instrumentation

Electrical Characteristics

Conductor Size: 0.75mm² 1.5mm²

Conductor Resistance: <24.5 Ohms/km <12.1 Ohms/km

Insulation Resistance: 940 MOhm x km 730 MOhm x km

Mutual Capacitance @ 800Hz:

Collective Screen: 80nF/km 90nF/km

Individual Screen: 90nF/km 110nF/km

Construction

Collectively Screened

Tinned copper wire conductors to IEC 60228 class 2, mica glass

tape fire barrier, EPR insulation, cores twisted into pairs or triples,

overall foil screen and drain wire, LSHF bedding, galvanised steel

wire braid armour, SW4 oil resistant LSHF sheath - grey, blue or

black.

Individually Screened

Tinned copper wire conductors to IEC 60228 class 2, mica glass

tape fire barrier, EPR insulation, cores twisted into pairs or

triples, each pair aluminum foil screened with a drain wire,

LSHF bedding, galvanised steel wire braid armour, SW4 oil

resistant LSHF sheath – grey, blue or black.

Class 5 conductors to IEC 60228 can be supplied on request.

Technical Information

Voltage Rating: 150/250V

Conductor Stranding: IEC 60228 Class 2, tinned copper

Temperature Rating: -30°C to +85°C

Bending Radius Static: 8 x overall diameter

Oxygen Index of Sheath: >31%

Fire Resistant: IEC 60331-21

Flame Retardant: IEC 60332-1-2,

IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2, BS 7622

Halogen Emission: IEC 60754-1 & 2, BS 6425-1

Oil Resistant: BS 7655 SW4 section 2.6

Manufactured To: BS 7917/BS 6883

Core Identification

Pairs - Black & white

Triples - Black, white & red

Each pair is identified by a numbered tape or printed numbers

on the cores.

Part No. No. of Pairs mm² Weight kg/km Dia. over Bedding mm O/D mm

Pairs Collectively Screened658C0702PHMxx 2 0.75 379 13.5 15.5658C0703PHMxx 3 0.75 460 13.0 17.5658C0707PHMxx 7 0.75 741 17.5 21.5658C0712PHMxx 12 0.75 1120 22.5 27.5658C0719PHMxx 19 0.75 1600 26.0 32.0658C0720PHMxx 20 0.75 1720 27.0 33.0658C0727PHMxx 27 0.75 2190 31.0 37.5

658C1502PHMxx 2 1.5 477 13.5 17.5658C1503PHMxx 3 1.5 570 14.5 19.0658C1507PHMxx 7 1.5 920 19.5 24.0658C1512PHMxx 12 1.5 1560 26.0 31.5658C1520PHMxx 20 1.5 2260 31.0 37.5658C1527PHMxx 27 1.5 2820 35.5 42.0

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

112 MOG BS 7917 658M-SW4 Shipwiring Instrumentation

658C0707PHM05

Part No. No. of Pairs mm² Weight kg/km Dia. over Bedding mm O/D mm

Pairs Individually Screened

658I0701PHMxx 1 0.75 260 8.0 12.0

658I0702PHMxx 2 0.75 420 11.0 17.0

658I0703PHMxx 3 0.75 480 13.5 17.5

658I0707PHMxx 7 0.75 795 20.0 22.0

658I0712PHMxx 12 0.75 1225 24.0 28.5

658I0720PHMxx 20 0.75 2050 30.0 36.5

658I0727PHMxx 27 0.75 2410 35.0 41.0

658I1501PHMxx 1 1.5 300 9.5 13.0

658I1502PHMxx 2 1.5 511 13.0 18.0

658I1503PHMxx 3 1.5 650 15.0 21.0

658I1507PHMxx 7 1.5 1030 20.5 25.0

658I1512PHMxx 12 1.5 1650 27.5 32.0

658I1520PHMxx 20 1.5 2690 34.0 41.0

Part No. No. of Triples mm² Weight kg/km Dia. over Bedding mm O/D mm

Triples Collectively Screened

658C0703THMxx 3 0.75 550 15.0 19.0

658C0707THMxx 7 0.75 930 19.5 24.5

658C0712THMxx 12 0.75 1450 26.0 31.5

658C1503THMxx 3 1.5 615 15.5 19.5

658C1507THMxx 7 1.5 1010 22.0 25.0

658C1512THMxx 12 1.5 1560 26.0 29.0

Triples Individually Screened

658I0701THMxx 1 0.75 280 8.5 12.5

658I0703THMxx 3 0.75 590 14.5 19.0

658I0707THMxx 7 0.75 990 20.0 24.5

658I0712THMxx 12 0.75 1650 26.5 32.5

658I1501THMxx 1 1.5 330 10.0 14.0

658I1503THMxx 3 1.5 850 16.5 19.0

658I1507THMxx 7 1.5 1180 20.0 25.0

658I1512THMxx 12 1.5 1740 32.5 38.0

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

113BS 7917 658M-SW4 Shipwiring Instrumentation MOG

To show the colour required please replace xx in the part number with:

05 Grey 01 Blue 00 Black

Other pair and triple configurations available on request

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

BFOU is similar to RFOU but has the benefit of mica tape around the conductor to maintain circuit integrity for 3 hours whenexposed to fire in accordance with IEC 60331-21. Designed to NEK606 and IEC 60092-353 BFOU meets the most stringentfire resistant, flame retardant and low smoke emission tests making it the ideal choice for low voltage power and controlapplications on FPSO, ship and platform applications.

Construction

Tinned stranded copper conductor, mica glass tape fire

barrier, EPR insulation, halogen free thermoplastic

elastomeric bedding, tinned copper wire braid armour,

MUD resistant LSHF elastomeric outer sheath.

The cross sectional area (mm2) of the screen is shown after

the conductor size in the table below.

Core Construction

1 Core Black

2 Cores Light grey, black

3 Cores Light grey, black, red

4 Cores Light grey, black, red, blue

5 Cores and above number coded

BFO06004

BFOU Power to IEC 60092-353

Technical Information

Voltage Rating: 0.6/1kV

Conductor Stranding: IEC 60228 Class 2, tinned copper

Current Rating: FEA-M clause 1881.5 – 11 or IEE regs.

table 4H2A+B depending on application

Temperature Rating: -40°C to +85°C

Bending Radius Static: 6 x overall diameter

Oxygen Index of Sheath: >31%

Fire Resistant: IEC 60331-21

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2

Halogen Emission: IEC 60754-1 & 2

MUD Resistant: NEK 606 P5/P12

Manufactured To: IEC 60092-353, NEK 606

3rd Party Approval: DNV, approvals may vary between

manufacture brands.

Part No. Cores x mm² Weight kg/km Dia. over Bedding mm O/D mm

BFOU PowerBFO01502 2 x 1.5/4 280 10.0 13.5BFO01503 3 x 1.5/4 310 10.5 14.5BFO01504 4 x 1.5/4 390 11.5 16.5BFO01507 7 x 1.5/6 570 14.0 18.0

BFO01512 12 x 1.5/10 780 18.5 23.5BFO01519 19 x 1.5/10 1080 22.0 27.5BFO01527 27 x 1.5/10 1430 26.5 32.0

BFO02502 2 x 2.5/4 320 11.0 14.5BFO02503 3 x 2.5/6 400 11.5 16.0BFO02504 4 x 2.5/6 460 12.5 17.0BFO02507 7 x 2.5/6 650 15.0 20.0BFO02512 12 x 2.5/10 980 20.0 25.0BFO02519 19 x 2.5/10 1350 24.0 29.0BFO02527 27 x 2.5/16 1810 29.5 34.5

BFO04002 2 x 4/6 420 12.0 16.5BFO04003 3 x 4/6 505 13.0 17.0BFO04004 4 x 4/6 590 14.0 19.0BFO06002 2 x 6/6 510 13.0 18.0BFO06003 3 x 6/6 595 14.0 18.5BFO06004 4 x 6/6 700 15.5 20.0

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

114 MOG BFOU Power to IEC 60092-353

Part No. Cores x mm² Weight kg/km Dia. over Bedding mm O/D mm

BFO10002 2 x 10/10 680 15.0 20.0

BFO10003 3 x 10/10 780 16.0 20.5

BFO10004 4 x 10/10 935 18.0 23.0

BFO16002 2 x 16/16 960 17.5 23.0

BFO16003 3 x 16/16 1120 18.5 24.0

BFO16004 4 x 16/16 1370 20.5 26.0

BFO25001 1 x 25/4 480 11.5 15.5

BFO25002 2 x 25/16 1250 21.0 26.0

BFO25003 3 x 25/16 1500 22.5 27.5

BFO25004 4 x 25/16 1850 25.0 30.0

BFO35001 1 x 35/6 640 13.5 17.0

BFO35002 2 x 35/16 1455 23.5 28.0

BFO35003 3 x 35/16 1950 25.0 30.0

BFO35004 4 x 35/16 2380 28.0 33.5

BFO50001 1 x 50/6 820 15.0 19.5

BFO50002 2 x 50/25 2160 27.0 32.5

BFO50003 3 x 50/25 2640 29.0 34.0

BFO50004 4 x 50/25 3300 32.5 38.5

BFO70001 1 x 70/6 1080 16.5 21.0

BFO70002 2 x 70/35 2930 31.0 37.0

BFO70003 3 x 70/35 3630 33.0 39.0

BFO70004 4 x 70/35 4340 37.0 43.0

BFO95001 1 x 95/10 1380 18.5 23.0

BFO95003 3 x 95/50 4720 38.0 44.0

BFO95004 4 x 95/50 5830 42.5 49.0

BFO12001 1 x 120/10 1710 20.5 25.5

BFO12003 3 x 120/60 5820 41.0 48.5

BFO12004 4 x 120/60 7180 46.0 54.0

BFO15001 1 x 150/10 2030 23.0 28.0

BFO18501 1 x 185/10 2510 25.0 30.0

BFO24001 1 x 240/16 3130 28.0 34.0

BFO30001 1 x 300/16 3820 31.0 37.0

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

115BFOU Power to IEC 60092-353 MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

BFOU instrumentation cables are designed to meet the needs of circuit integrity installations within the offshore industry.They are available as collectively or individually screened options for optimum EMI screening. Fire barrier tapes are combined with a Low Smoke Halogen Free sheath to provide uninterrupted signals during a fire situation. BFOU cables are also resistant to MUD and drilling oils and meet the flame retardance requirements of IEC 60332-3-22 Cat A.

BFOU Instrumentation to IEC 60092-376

Construction

Tinned stranded copper conductor, mica tape, EPR insulation,

overall screen of copper backed polyester tape with a stranded

copper drain wire, inner sheath of halogen free elastomeric,

tinned copper wire braid armour, MUD resistant - LSHF

elastomeric sheath. The individually screened version has a

copper backed polyester tape with a stranded copper drain wire

around each pair or triple.

Core Identification

Pairs - Light blue, black and numbered

Triples – Light blue, black, brown and numbered

Part No. No. of Pairs mm² Weight kg/km Dia. over Bedding mm O/D mm

Pairs Collectively ScreenedBFC00702xx 2 0.75 340 10.5 14.5BFC00703xx 3 0.75 421 12.0 15.5BFC00704xx 4 0.75 450 12.5 16.0BFC00708xx 8 0.75 700 16.5 21.0BFC00712xx 12 0.75 915 19.5 23.5BFC00716xx 16 0.75 1100 21.0 25.5BFC00724xx 24 0.75 1600 26.5 31.5

BFC01502xx 2 1.5 450 13.0 16.5BFC01503xx 3 1.5 521 14.0 18.4BFC01504xx 4 1.5 600 15.0 19.0BFC01508xx 8 1.5 1020 20.0 25.0BFC01512xx 12 1.5 1330 23.5 28.5BFC01516xx 16 1.5 1620 26.0 30.5BFC01524xx 24 1.5 2450 32.0 38.5

Electrical Characteristics

Conductor Size: 0.75mm² 1.5mm²

Conductor Resistance: <26.7 Ohms/km <13.7 Ohms/km

L/R Ratio: 12.7mH/Ohm 26.6mH/Ohm

Mutual Capacitance @ 800Hz:

Collective Screen: 100nF/km 110nF/km

Individual Screen: 110nF/km 125nF/km

Technical Information

Voltage Rating: 250V

Conductor Stranding: IEC 60228 Class 2, tinned copper

Temperature Rating: -40°C to +85°C

Bending Radius Static: 6 x overall diameter

Oxygen Index Of Sheath: >31%

Fire Resistant: IEC 60331-21

Flame Retardant: IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission: IEC 61034-1 & 2

Halogen Emission: IEC 60754-1 & 2

MUD Resistant: NEK606 Collective Screen S4/S8,

Individual Screen S3/S7

Manufactured To: IEC 60092-376, NEK606

3rd Party Approval: DNV, approvals may vary between

manufacture brands.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

116 MOG BFOU Instrumentation to IEC 60092-376

BFC0070805

Part No. No. of Pairs mm² Weight kg/km Dia. over Bedding mm O/D mm

Part No. No. of Triples mm² Weight kg/km Dia. over Bedding mm O/D mm

Triples Collectively ScreenedBFC00702Txx 2 0.75 415 12.0 15.5BFC00704Txx 4 0.75 550 14.0 18.0BFC00708Txx 8 0.75 880 18.5 23.0BFC00712Txx 12 0.75 1180 22.0 26.5BFC00716Txx 16 0.75 1400 24.0 29.0BFC00724Txx 24 0.75 2150 30.0 35.0

BFC01502Txx 2 1.5 550 14.5 18.0BFC01504Txx 4 1.5 770 17.0 21.0BFC01508Txx 8 1.5 1270 22.5 27.0BFC01512Txx 12 1.5 1720 27.0 32.0BFC01516Txx 16 1.5 2330 30.0 35.0BFC01524Txx 24 1.5 3350 37.0 43.5

Triples Individually ScreenedBFI00701Txx 1 0.75 220 8.0 11.0BFI00702Txx 2 0.75 420 12.0 15.0BFI00703Txx 3 0.75 580 14.0 17.0BFI00704Txx 4 0.75 591 14.5 20.0BFI00708Txx 8 0.75 980 18.5 23.0BFI00712Txx 12 0.75 1320 22.5 27.0BFI00716Txx 16 0.75 1650 25.5 30.0BFI00724Txx 24 0.75 2520 31.5 37.5

BFI01501Txx 1 1.5 290 9.5 12.5BFI01502Txx 2 1.5 570 14.5 18.5BFI01503Txx 3 1.5 730 17.5 20.5BFI01504Txx 4 1.5 825 17.0 21.0BFI01508Txx 8 1.5 1410 22.5 27.0BFI01512Txx 12 1.5 1980 28.5 33.0BFI01516Txx 16 1.5 2620 31.5 37.5BFI01524Txx 24 1.5 3790 39.5 46.5

Pairs Individually ScreenedBFI00701xx 1 0.75 200 7.5 11.0BFI00702xx 2 0.75 370 11.0 14.5BFI00703xx 3 0.75 500 12.5 16.5BFI00704xx 4 0.75 519 15.0 18.5BFI00708xx 8 0.75 820 17.0 21.5BFI00712xx 12 0.75 1075 20.5 25.0BFI00716xx 16 0.75 1320 23.0 27.5BFI00724xx 24 0.75 2050 29.0 34.5

BFI01501xx 1 1.5 260 9.0 12.0BFI01502xx 2 1.5 490 13.0 17.0BFI01503xx 3 1.5 601 15.5 19.5BFI01504xx 4 1.5 650 15.5 19.5BFI01508xx 8 1.5 1140 21.0 25.0BFI01512xx 12 1.5 1520 25.0 30.0BFI01516xx 16 1.5 1950 29.0 34.0BFI01524xx 24 1.5 2900 35.5 42.0

To show the colour required please replace xx in the part number with:

05 Grey 01 Blue 00 Black

Other pair and triple configurations available on request. 2.5mm2 conductor sizes are available in some sizes, please contact us for more information.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

117BFOU Instrumentation to IEC 60092-376 MOG

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Used extensively for trailing and flexible supply leads, these rubber cables remain flexible even at sub-zero temperatures.

H05RR-F uses a standard grade rubber compound for the outer sheath and is suitable for light duty applications.

H05RR-F Multicores

55101503

The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerablyin diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we willcheck the stock you will be sent.

Also available in a special blue sheathed version suitable for use in drinking water.

G = With Green/Yellow X = Without Green/Yellow

Application

Light portable tools, temporary or portable lighting,

extension leads for indoor or outdoor use where there

is minimal physical damage expected.

Construction

Fine copper wire strands to IEC 60228 class 5.

Rubber insulation colour coded to BS 7671/HD 308 S2.

Cores twisted together. Black rubber outer sheath to

BS 6500:2000 table 12 and BS 7919:2001 table 10.

Technical Information

Voltage Rating: Working 300/500V Test 2000V

Temperature Rating: -25°C to +60°C

Bending Radius: Flexing 15 x cable diameter

Static 6 x cable diameter

Current Rating: H05RR-F Refer to IEE Regs Table 4HF3A&B

Conductor Stranding: To IEC 60228 Class 5 &

VDE 0295 Class 5.

Part No. Cores x mm² O/D mm

55100702 2 x 0.75 6.6

55100703 3 G 0.75 7.1

55101002 2 x 1.0 7.1

55101003 3 G 1.0 7.6

55101004 4 G 1.0 8.1

55101502 2 x 1.5 8.8

55101503 3 G 1.5 9.4

55101504 4 G 1.5 10.3

55101505 5 G 1.5 10.6

55102502 2 x 2.5 10.2

55102503 3 G 2.5 10.8

55102504 4 G 2.5 12.1

55102505 5 G 2.5 11.8

118 RUBBER & CRANE H05RR-F

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

H07RN-F Single & Multicores

57101503

The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerablyin diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we willcheck the stock you will be sent. Also available in a special blue sheathed version suitable for use in drinking water.

G = With Green/Yellow X = Without Green/Yellow

Application

Portable saws, grinders, welders, pumps, transformers, as temporary lighting cable and feed cable to heavymobile equipment. Single cores and large multicores areoften used as distribution cables from mobile generators.

Construction

Fine copper wire strands to IEC 60228 class 5. Rubber insulation colour coded to BS 7671/HD 308 S2(cables with over 5 cores, A07RN-F, are number coded).Cores twisted together. Black neoprene (PCP) outersheath to BS 7919:2001 table 14.

Technical Information

Voltage Rating: Working 450/750V Test 3000V

Temperature Rating: -20°C to +60°C. + 85°C for static applications

Bending Radius: Flexing 15 x cable diameter

Static 6 x cable diameter

Current Rating: H07RN-F Refer to IEE Regs Table 4F1A&B

Conductor Stranding: To IEC 60228 Class 5 & VDE 0295 Class 5.

Used extensively for trailing and flexible supply leads in either single or multicore versions, these rubber cables remainflexible even at sub-zero temperatures.

H07RN-F uses neoprene (PCP) for its sheath. The improved abrasion resistance and the ability to withstand many oils andchemicals make the neoprene sheathed cables suitable for the most arduous conditions.

Part No. Cores x Weight O/Dmm² kg/km mm

57101002 2 x 1.0 92 8.357101003 3 G 1.0 111 8.957101004 4 G 1.0 134 9.757101501 1 x 1.5 48 5.957101502 2 x 1.5 109 8.757101503 3 G 1.5 137 9.757101504 4 G 1.5 169 10.757101505 5 G 1.5 206 11.657101507 7 G 1.5 371 16.057101512 12 G 1.5 546 20.057101519 19 G 1.5 777 23.557101527 27 G 1.5 1090 27.557101537 37 G 1.5 1300 31.057102501 1 x 2.5 62 6.557102502 2 x 2.5 162 10.657102503 3 G 2.5 198 11.457102504 4 G 2.5 244 12.657102505 5 G 2.5 299 14.057102507 7 G 2.5 461 18.257102512 12 G 2.5 758 2457102519 19 G 2.5 1100 24.557102527 27 G 2.5 1590 32.157104001 1 x 4.0 88 7.557104002 2 x 4.0 220 12.057104003 3 G 4.0 276 13.157104004 4 G 4.0 343 14.457104005 5 G 4.0 431 16.357106001 1 x 6.0 116 8.357106002 2 x 6.0 295 13.757106003 3 G 6.0 370 14.857106004 4 G 6.0 474 16.757106005 5 G 6.0 585 18.457110001 1 x 10 182 10.157110002 2 x 10 522 18.1

Part No. Cores x Weight O/Dmm² kg/km mm

57110003 3 G 10 668 20.157110004 4 G 10 822 21.657110005 5 G 10 1010 24.257116001 1 x 16 250 11.457116002 2 x 16 738 21.657116003 3 G 16 906 22.657116004 4 G 16 1120 24.657116005 5 G 16 1380 27.157125001 1 x 25 361 13.457125003 3 G 25 1360 27.457125004 4 G 25 1730 30.757125005 5 G 25 2110 33.657135001 1 x 35 469 14.757135003 3 G 35 1700 29.757135004 4 G 35 2180 33.257135005 5 G 35 2680 41.357150001 1 x 50 671 17.557150003 3 G 50 2410 35.457150004 4 G 50 3060 39.257150005 5 G 50 4383 47.357170001 1 x 70 892 19.657170003 3 G 70 3180 39.657170004 4 G 70 4040 43.357170005 5 G 70 5398 56.257195001 1 x 95 1140 22.057195003 3 G 95 4070 45.257195004 4 G 95 5300 50.557112001 1 x 120 1420 24.257112003 3 G 120 4936 53.757112004 4 G 120 6499 59.557115001 1 x 150 1760 26.657115004 4 G 150 8101 65.557118501 1 x 185 2090 28.857118504 4 G 185 10029 76.557124001 1 x 240 2710 32.257130001 1 x 300 3310 34.9

119H07RN-F RUBBER & CRANE

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

NSHTöu is designed specifically for drum reeling applications. On anything from dockside cranes to automated conveyorsystems, NSHTöu copes with incredible workloads. Good UV and weather resistance makes the cable suitable for exposedoutdoor installation.

A special low temperature type is available to work down to -40°C. Other sizes and high tensile versions using Kevlar strainrelief elements are also available. Medium and high voltage variants are available usually with red PCP outer sheaths.

NSHTöu Drum Reeling

Construction

Fine copper wire strands to IEC 60228. Rubber

insulation, 4 & 5 core colour coded, six core and above,

black with white numbers. Green/yellow earth core in all

cables. Cores twisted together with short lay length.

Black neoprene (PCP) dual layer outer sheath with

integral textile braid.

Technical Information

Voltage Rating: Working 0.6/1kV Test 2500V

Temperature Rating: Flexing -25°C to +60°C

Bending Radius: Up to 20mm diameter:

10 x cable diameter

Flexing above 20mm diameter:

12.5 x cable diameter

51106004

* The 5 x 1.5mm2 signal cores are individually screened.

Part No. Cores x Weight O/Dmm² kg/km mm

51101504 4 x 1.5 301 15

51101505 5 x 1.5 342 16

51101507 7 x 1.5 419 20

51101512 12 x 1.5 620 22

51101518 18 x 1.5 875 27

51101524 24 x 1.5 1020 29

51101530 30 x 1.5 1362 31

51101542 42 x 1.5 1724 35

51102504 4 x 2.5 374 17

51102505 5 x 2.5 486 19

51102507 7 x 2.5 506 22

51102508 8 x 2.5 704 24

51102512 12 x 2.5 891 26

51102516 16 x 2.5 1103 28

51102518 18 x 2.5 1208 30

51102519 19 x 2.5 1282 31

51102524 24 x 2.5 1562 35

51102530 30 x 2.5 1819 36

51102536 36 x 2.5 2327 40

51102542 42 x 2.5 2860 45

51104004 4 x 4 526 19

Part No. Cores x Weight O/Dmm² kg/km mm

51104005 5 x 4 636 21

51104008 8 x 4 1015 27

51106004 4 x 6 688 21

51106005 5 x 6 855 23

51110004 4 x 10 1047 26

51110005 5 x 10 1190 28

51116004 4 x 16 1280 29

51116005 5 x 16 1803 32

51125004 4 x 25 2102 35

51135004 4 x 35 2751 39

51150004 4 x 50 3695 45

51170004 4 x 70 5401 49

51195004 4 x 95 6985 57

51112004 4 x 120 8294 60

51115004 4 x 150 8989 65

51301525* 25x1.5+5x1.5(C) 2142 40

51302519* 19x2.5+5x1.5(C) 1757 34

51302525* 25x2.5+5x1.5(C) 2010 37

51501506 3 x (2 x 1.5)(C) 608 23

51501512 6 x (2 x 1.5)(C) 984 31

120 RUBBER & CRANE NSHTöu

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

Reelflex PUR-H is part of the latest generation of drum reeling cables. When compared to the standard rubber NSHTöu,Reelflex PUR-H is significantly smaller in overall diameter and lighter in weight. This allows the use of lighter winding/reelingequipment offering considerable cost savings. Ideal for use inside or in the open air, these cables emit very little smoke andare halogen free, making them suitable for sensitive applications in the event of fire.

Reelflex PUR-H Drum Reeling

Construction

Fine copper strands to IEC 60228 insulated with

halogen free polyester, cores laid around a central

textile suspension unit using a short length of twist.

Anti-torsion braid embedded between the inner and

outer halogen free black polyurethane sheath.

Some large sizes may have a split earth construction.

Please check at time of order if this is critical.

Technical Information

Voltage Rating: Working 0.6/1kV Test 2500V

Temperature Rating: Fixed Installation -50°C to +80°C

Flexing -40°C to +80°C

Bending Radius: Flexing 6 x cable diameter

Part No. Cores x Tensile Weight kg/km O/D mm mm² Stength Newtons

51101504P 4 x 1.5 1200 155 10.551101505P 5 x 1.5 1500 178 11.251101507P 7 x 1.5 2000 231 12.651101512P 12 x 1.5 2500 359 16.151101518P 18 x 1.5 2500 474 17.051101524P 24 x 1.5 2500 590 21.151101530P 30 x 1.5 2500 710 23.151101542P 42 x 1.5 2500 980 27.351301525 25 x 1.5 + 5 x 1.5 2500 730 23.451102504P 4 x 2.5 1500 208 11.551102505P 5 x 2.5 1800 241 12.251102507P 7 x 2.5 2500 308 13.251102512P 12 x 2.5 2500 480 19.551102518P 18 x 2.5 2500 679 19.851102524P 24 x 2.5 2500 820 24.151102530P 30 x 2.5 2500 970 27.351302519 19 x 2.5 + 5 x 1.5 2500 820 24.351104004P 4 x 4 1800 281 12.751104005P 5 x 4 2000 318 13.751106004P 4 x 6 2000 372 14.151106005P 5 x 6 2500 426 15.151110004P 4 x 10 2000 611 17.951110005P 5 x 10 2500 704 19.551116004P 4 x 16 2500 924 22.351116005P 5 x 16 2500 1067 24.251125004P 4 x 25 2500 1270 25.551135004P 4 x 35 2500 1720 28.351150004P 4 x 50 3000 2630 34.251170004P 4 x 70 4200 3326 39.851195004P 4 x 95 5700 4695 47.151112004P 4 x 120 7200 5565 52.151115004P 4 x 150 9000 6933 56.5

121Reelflex PUR-H RUBBER & CRANE

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

51102518P

PVC Flat cables offer good low temperature durability, flexing to -15ºC. Their relatively light weight increases the optionsavailable to designers as does the tight bending radius of 10 x the thickness of the cable. Used mainly within buildings ona wide variety of applications. These cables are not suitable for use in elevators.

Flat PVC Cables

Construction

Fine copper wire strands to IEC 60228 class 5. PVC

insulation, colour coded for cables with 2-5 cores,

six cores and above black PVC insulation with white

numbers. A green/yellow earth conductor is

included. Cores laid parallel. Black cold resistant PVC

outer sheath.

Technical Information

Voltage Rating: 0.75 & 1mm2 300/500V

1.5 - 50mm2 450/750V

Temperature Rating: Flexing -15°C to +70°C

Bending Radius: Flexing 10 x cable thickness

Current Rating: Refer to IEE Regs Table 4F3A&B

Conductor Stranding: To IEC 60228 Class 5

* Cores laid in Quad Format

Low Smoke Halogen Free versions, other core combinations and individually screened cores areavailable on request. Please call us with your requirements.

Part No. Cores x mm² Weight kg/km O/D mm

58100712 12 x 0.75 260 4.2 x 33.858100718 18 x 0.75 380 4.2 x 50.2 58100724 24 x 0.75 490 4.2 x 65.6 58101005 5 x 1.0 120 4.4 x 15.558101008 8 x 1.0 205 4.4 x 24.8 58101012 12 x 1.0* 335 9.5 x 22.5 58101016 16 x 1.0* 465 9.5 x 28.758101018 18 x 1.0 450 4.4 x 53.8 58101024 24 x 1.0 590 4.4 x 70.4 58101504 4 x 1.5 170 4.5 x 13.658101505 5 x 1.5 190 4.5 x 18.258101507 7 x 1.5 220 4.5 x 23.9 58101508 8 x 1.5 270 4.9 x 27.2 58101510 10 x 1.5 320 4.9 x 34.0 58101512 12 x 1.5 390 4.9 x 39.8 58101518 18 x 1.5 670 4.9 x 61.658101524 24 x 1.5 790 4.9 x 82.0 58102504 4 x 2.5 200 5.6 x 16.8 58102505 5 x 2.5 260 5.6 x 22.0 58102507 7 x 2.5 350 5.6 x 29.258102508 8 x 2.5 390 5.6 x 32.8 58102510 10 x 2.5 490 6.0 x 41.4 58102512 12 x 2.5 580 6.0 x 48.6 58102524 24 x 2.5 1200 6.0 x 104 58104004 4 x 4.0 320 7.0 x 21.2 58104005 5 x 4.0 400 7.0 x 27.4 58104007 7 x 4.0 540 7.0 x 36.6 58106004 4 x 6.0 432 8.2 x 24.858110004 4 x 10 680 10.0 x 29.658116004 4 x 16 970 11.2 x 34.458125004 4 x 25 1490 13.7 x 42.658135004 4 x 35 1980 15.4 x 47.6 58150004 4 x 50 2800 18.2 x 57.5

122 RUBBER & CRANE Flat PVC Cables

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

58101512

With the growth in renewable energy sources the demand for specialist cables to meet specific needshas also increased. While the cables used to link solar panels to each other or to a regulator arerelatively simple, the environments they operate in can be very hostile. Ultraviolet (UV) can beextremely damaging to conventional cable, breaking down standard insulation within a matter ofmonths in some cases. Heat and weather can also be very destructive.

The FSC range of solar panel or PV cables are designed to work in extreme conditions with a temperature range up to 120ºC and excellent UV stability.

Photovoltaic Cables

Construction

Tinned copper class 5 conductors, cross

linked polyolefin insulation, cross linked

polyolefin sheath.

Technical Information

Voltage Rating: Working 0.6/1kV

Test 3000V AC

Temperature Rating: Static -40ºC to + 120ºC

Flexing -40ºC to + 90ºC

Minimum Bending Radius: 4 x cable diameter

Part No. Size Stranding & mm Electrical Weight O/D mmmm² Resistance Ohm/km kg/km

PV02501xx 2.5 50 x 0.26 7.98 47 5.5

PV04001xx 4 56 x 0.31 4.95 76 6.1

PV06001xx 6 84 x 0.31 3.30 105 7.5

PV10001xx 10 80 x 0.41 1.91 151 8.9

PV16001xx 16 128 x 0.41 1.21 232 10.0

PV25001xx 25 200 x 0.41 0.780 342 11.4

PV35001xx 35 280 x 0.41 0.554 473 12.9

PV50001xx 50 400 x 0.41 0.386 648 15.3

PV70001xx 70 356 x 0.51 0.272 861 17.5

PV95001xx 95 485 x 0.51 0.206 1126 20.1

Cables with different insulation materials and jacket materials may be offered. If you require the cable tohave specific approvals please state at time of enquiry.

To show the colour required please replace xx in the part number with:

00 Black 03 Red

123Photovoltaic Cables RUBBER & CRANE

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

PV0400100

22501007

Hi-Flex HF-100 & HF-100-C PUR

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

124 ROBOTICS Hi-Flex HF-100 & HF-100-C PUR

Technical Information

Voltage Rating: Working 300/500VTest 3000V

Temperature Rating: Flexing -30°C to+80°CBending Radius: Flexing 5 x cable diameterCurrent Rating: Refer to IEE Regs Table

4F3A&BConductor Stranding: To IEC 60228 Class 6 &

VDE 0295 Table 4

Also available in 0.14mm2, 0.25mm2 and 0.34mm2

screened or unscreened with DIN47100 colourcodes. Please see page 126-127.

Reduced overall diameter versions are now available.Please call for details.

Construction - HF-100

Construction - HF-100-C Screened

Very fine copper wire strands to IEC 60228 Class 6.Black polyolefin insulation with white numbers. A green/yellow earth core is included in cables withmore than 2 cores. Cores twisted in layers & fleecetaped. Textured grey polyurethane sheath to RAL 7001.

Very fine copper wire strands to IEC 60228 Class 6.Black polyolefin insulation with white numbers. Agreen/yellow earth core is included in cables with morethan 2 cores. Cores twisted in layers & textile taped.Grey PVC inner sheath. Fleece tape. Tinned copperwire braid. Fleece wrap. Textured grey polyurethaneouter sheath to RAL 7001.

Part No. Cores x O/Dmm² mm

HF-10020500502 2 x 0.5 5.520500503 3 x 0.5 5.820500504 4 x 0.5 6.220500505 5 x 0.5 6.720500507 7 x 0.5 7.720500512 12 x 0.5 9.720500518 18 x 0.5 11.220500519 19 x 0.5 11.620500520 20 x 0.5 12.020500525 25 x 0.5 13.920500527 27 x 0.5 14.420500530 30 x 0.5 15.520500536 36 x 0.5 16.2

20500702 2 x 0.75 6.120500703 3 x 0.75 6.420500704 4 x 0.75 6.820500705 5 x 0.75 7.420500707 7 x 0.75 8.820500712 12 x 0.75 10.820500718 18 x 0.75 12.720500720 20 x 0.75 13.420500725 25 x 0.75 15.120500727 27 x 0.75 15.6

Part No. Cores x O/Dmm² mm

20500730 30 x 0.75 16.220500736 36 x 0.75 18.0

20501002 2 x 1 6.720501003 3 x 1 7.120501004 4 x 1 7.520501005 5 x 1 8.620501007 7 x 1 0.220501012 12 x 1 12.820501018 18 x 1 14.320501020 20 x 1 14.720501025 25 x 1 16.920501027 27 x 1 17.620501030 30 x 1 18.220501036 36 x 1 20.3

20501502 2 x 1.5 7.920501503 3 x 1.5 8.320501504 4 x 1.5 8.920501505 5 x 1.5 9.920501507 7 x 1.5 11.920501512 12 x 1.5 14.920501518 18 x 1.5 16.820501520 20 x 1.5 17.6

Abrasion on cables that are constantly flexing is becoming a much more widespread problem. Toovercome this, FS Cables have introduced the HF-100 range of polyurethane sheathed cables whichwill outlast conventional PVC sheathing.

The low friction polyurethane sheath resists wear caused by constant rubbing either in a cable chain orwhere free movement brings the cable into contact with part of the machine. Suitable for use in cablechains as well as for free movement the HF-100 range will provide a long term solution to manyregular flexing applications.

Both the screened and unscreened versions use fleece tapes and talcum to enable the core bundle and,where appropriate, the screening braid to move as the cable flexes. This reduces the stress imposed onthe conductors and braid.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

125Hi-Flex HF-100 & HF-100-C PUR ROBOTICS

Part No. Cores x O/Dmm² mm

20501525 25 x 1.5 20.820501527 27 x 1.5 21.120501530 30 x 1.5 21.720501536 36 x 1.5 23.5

20502503 3 x 2.5 9.820502504 4 x 2.5 10.720502505 5 x 2.5 11.520502507 7 x 2.5 13.520502512 12 x 2.5 17.320502518 18 x 2.5 20.320502525 25 x 2.5 25.0

20504004 4 x 4 13.120504005 5 x 4 14.8

20506004 4 x 6 14.920506005 5 x 6 16.9

20510004 4 x 10 19.2

20516004 4 x 16 24.0

20525004 4 x 25 26.3

Part No. Cores x O/Dmm² mm

22500727 27 x 0.75 19.022500730 30 x 0.75 19.022500736 36 x 0.75 20.4

22501002 2 x 1 8.922501003 3 x 1 9.222501004 4 x 1 9.722501005 5 x 1 10.522501007 7 x 1 12.722501012 12 x 1 14.922501018 18 x 1 16.922501020 20 x 1 16.922501025 25 x 1 21.022501027 27 x 1 21.122501030 30 x 1 21.222501036 36 x 1 22.5

22501502 2 x 1.5 10.222501503 3 x 1.5 10.922501504 4 x 1.5 11.822501505 5 x 1.5 12.022501507 7 x 1.5 13.922501512 12 x 1.5 17.022501518 18 x 1.5 20.322501520 20 x 1.5 20.922501525 25 x 1.5 24.122501527 27 x 1.5 24.422501530 30 x 1.5 24.822501536 36 x 1.5 27.0

22502503 3 x 2.5 11.722502504 4 x 2.5 12.722502505 5 x 2.5 13.622502507 7 x 2.5 15.922502512 12 x 2.5 18.122502518 18 x 2.5 20.9

22506004 4 x 6 20.4

Part No. Cores x O/Dmm² mm

22500502 2 x 0.5 8.222500503 3 x 0.5 8.922500504 4 x 0.5 9.122500505 5 x 0.5 9.622500507 7 x 0.5 10.822500512 12 x 0.5 13.122500518 18 x 0.5 14.822500520 20 x 0.5 14.922500525 25 x 0.5 17.822500527 27 x 0.5 18.022500530 30 x 0.5 18.122500536 36 x 0.5 18.6

22500702 2 x 0.75 8.522500703 3 x 0.75 8.922500704 4 x 0.75 9.922500705 5 x 0.75 10.522500707 7 x 0.75 11.722500712 12 x 0.75 13.722500718 18 x 0.75 15.522500720 20 x 0.75 16.322500725 25 x 0.75 18.9

20500112

Hi-Flex 120 & 120-C screened data cables are designed to last even in the most hostile chain or freemovement applications. The HF-120-C copper braid screened version protects the signal from EMIwhile the TPE insulation supports the highly flexible conductors. Abrasion is reduced to a minimum byusing a polyurethane low friction sheath. For maximum life Hi-Flex Data cables should not be exposedto torsional stresses or twisting. Many sizes now available with UL approval.

HF-120 Unscreened & HF-120-C Screened

22500207

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

126 ROBOTICS HF-120 Unscreened & HF-120-C Screened

Technical Information

Voltage Rating: Working 250VTest 1500V

Temperature Rating: Flexing -30°C to +80°C Bending Radius: Flexing 7.5 x cable diameter

Construction - HF-120 & HF-120-C

Very fine copper wire strands. Polyolefin insulationcolour coded to DIN 47100. Cores twisted inlayers & fleece taped. (Screened versions have atinned copper wire braid & fleece wrap). Lowfriction polyurethane outer sheath. Colour chartpage 80.

Part No. Cores x Weight O/Dmm² kg/km mm

HF-120 Unscreened20500102 2 x 0.14 22 4.1

20500103 3 x 0.14 27 4.4

20500104 4 x0.14 30 4.7

20500105 5 x 0.14 36 5.0

20500107 7 x 0.14 48 5.8

20500110 10 x 0.14 63 6.0

20500112 12 x 0.14 69 6.1

20500114 14 x 0.14 73 6.7

20500118 18 x 0.14 85 7.0

20500125 25 x 0.14 125 8.3

20500202 2 x 0.25 26 4.3

20500203 3 x 0.25 30 4.6

20500204 4 x 0.25 39 5.0

20500205 5 x 0.25 49 5.2

20500207 7 x 0.25 59 6.1

20500210 10 x 0.25 83 7.4

20500212 12 x 0.25 95 8.2

20500214 14 x 0.25 106 8.5

20500218 18 x 0.25 129 9.0

20500225 25 x 0.25 168 11.1

20500302 2 x 0.34 33 4.8

20500303 3 x 0.34 43 95.2

20500304 4 x 0.34 55 5.9

20500305 5 x 0.34 66 6.4

20500307 7 x 0.34 79 7.3

20500310 10 x 0.34 107 8.8

20500312 12 x 0.34 128 8.9

20500314 14 x 0.34 148 9.4

20500318 18 x 0.34 180 10.3

20500325 25 x 0.34 250 12.4

Part No. Cores x Weight O/Dmm² kg/km mm

HF-120-C Unscreened22500102 2 x 0.14 31 4.622500103 3 x 0.14 35 4.822500104 4 x 0.14 40 5.022500105 5 x 0.14 45 5.222500107 7 x 0.14 59 5.722500110 10 x 0.14 79 6.222500112 12 x 0.14 93 6.722500114 14 x 0.14 102 7.422500118 18 x 0.14 113 7.922500125 25 x 0.14 150 9.6

22500202 2 x 0.25 36 4.822500203 3 x 0.25 41 5.422500204 4 x 0.25 47 5.722500205 5 x 0.25 63 6.122500207 7 x 0.25 79 6.722500210 10 x 0.25 10 68.322500212 12 x 0.25 119 8.622500214 14 x 0.25 139 8.822500218 18 x 0.25 158 9.522500225 25 x 0.25 196 11.5

22500302 2 x 0.34 44 5.622500303 3 x 0.34 58 6.022500304 4 x 0.34 79 6.322500305 5 x 0.34 86 6.622500307 7 x 0.34 110 7.922500310 10 x 0.34 153 9.122500312 12 x 0.34 164 9.622500314 14 x 0.34 183 9.822500318 18 x 0.34 224 10.722500324 24 x 0.34 319 13.122500325 25 x 0.34 325 13.2

22600504

The Hi-Flex twisted pair data cable is ideally suited to mechanically challenging data transmissionapplications. The tough polyurethane jacket is cut and abrasion resistant, while being unaffected bymany solvents and oils. The tinned copper braid screen copes well with frequent flexing and at the sametime maintains signal integrity by minimising the efforts of electromagnetic interference. Many sizesnow available with UL approval.

HF-120-C-TP Paired Screened

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

127HF-120-C-TP Paired Screened ROBOTICS

Technical Information

Voltage Rating: Working 250VTest 1500V

Temperature Rating: Flexing -30°C to +80°CBending Radius: Flexing 10 x cable diameter

Construction - HF-120-C Screened

Very fine copper wire strands. Polyolefininsulation colour coded to DIN 47100. Corestwisted in pairs and laid up with fleece wrap,tinned copper wire braid. Fleece wrap. Lowfriction polyurethane outer sheath.

Part No. Pairs x Weight O/Dmm² kg/km mm

22600201 1 x 2 x 0.25 38 4.9

22600202 2 x 2 x 0.25 44 5.9

22600203 3 x 2 x 0.25 46 6.2

22600204 4 x 2 x 0.25 59 6.6

22600205 5 x 2 x 0.25 70 7.7

22600206 6 x 2 x 0.25 79 8.2

22600208 8 x 2 x 0.25 117 9.1

22600210 10 x 2 x 0.25 126 10.3

22600214 14 x 2 x 0.25 163 11.2

22600501 1 x 2 x 0.5 51 5.5

22600502 2 x 2 x 0.5 79 7.0

22600503 3 x 2 x 0.5 90 8.4

22600504 4 x 2 x 0.5 118 9.2

22600505 5 x 2 x 0.5 135 10.2

22600506 6 x 2 x 0.5 162 11.3

22600508 8 x 2 x 0.5 240 12.3

22600510 10 x 2 x 0.5 255 14.7

22600514 14 x 2 x 0.5 328 15.9

Part No. Pairs x Weight O/Dmm² kg/km mm

22600701 1 x 2 x 0.75 108 6.1

22600702 2 x 2 x 0.75 115 8.6

22600703 3 x 2 x 0.75 123 9.6

22600704 4 x 2 x 0.75 148 10.4

22600705 5 x 2 x 0.75 180 11.5

22600706 6 x 2 x 0.75 209 12.7

22600708 8 x 2 x 0.75 305 13.8

22600710 10 x 2 x 0.75 327 16.3

22600714 14 x 2 x 0.75 420 17.8

22601001 1 x 2 x 1 108 6.3

22601002 2 x 2 x 1 128 9.1

22601003 3 x 2 x 1 140 9.9

22601004 4 x 2 x 1 171 10.8

22601005 5 x 2 x 1 206 11.8

26500241

HF-265 PUR Encoder

Technical Information

Voltage Rating: Working 300VTest 2000V

Temperature Rating: Flexing -30°C to +80°CBending Radius: Flexing 10 x cable diameter

Construction - HF-265 PUR Encoder

Very fine copper wire strands to IEC 60228 Class 6. Polyproplene insulation, colour coded.Cores twisted in layers, including screened pairs & fleece taped. Tinned copper wire braid. Fleecewrap. Low friction polyurethane outer sheath.Colour green.Please note individual types may vary in construction from the above.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

128 ROBOTICS HF-265 PUR Encoder

Part No. Cores x Weight O/D Systemmm² kg/km mm

265001125 10 x 0.14 + 2 x 0.5 70 8.1 Heidenhain265001145 10 x 0.14 + 4 x 0.5 86 8.5 Heidenhain265001545 15 x 0.14 + 4 x 0.5 127 8.9 Bosch26500135 3 x (2 x 0.14) + 2 x (0.5) 101 8.2 Heidenhain/Sinumerik26500131 3 x (2 x 0.14) + 2 x (1.0) 109 8.5 Heidenhain26500145 4 x 2 x 0.14 + 4 x 0.5 111 8.3 Heidenhain26500275 4 x 2 x 0.25 + 2 x 0.5 123 8.9 Indramat26500241 4 x 2 x 0.25 + 2 x 1.0 135 8.9 Indramat26500345 4 x 2 x 0.38 + 4 x 0.5 199 8.7 Sinumerik26500509 9 x 0.5 126 8.7 Indramat26500132 3 x (2 x 0.14)+4 x 0.14 + 2 x 0.5 127 9.1 Sinumerik26500134 3x(2x0.14)+4x0.14+4x0.23+2x0.5 149 10.2 Sinumerik26500102 2 x 2 x 0.18 45 5.7 Sinumerik26500104 4 x 2 x 0.18 57 6.6 Sinumerik26500108 8 x 2 x 0.18 126 8.7 Sinumerik26500212 12 x (2 x 0.25) 208 12.6 Sinumerik26500224 4 x (2 x 0.14) 92 5.9 Heidenhain26500144 4 x 2 x 0.14 + 4 x 0.25 97 6.3 Heidenhain

Used for precise data transmission, these cables meet the specific requirements of automation controlgear manufacture. Fine copper wire strands with high performance insulation and sheathing materialsmake them ideal for regular flexing applications including use in cable chains where cut and abrasionresistance is vital.

Manufactured to DESINA® with UL and CSA approval these cables also conform to EU low voltageguide lines 73/23/EWG ™,ensuring they are widely accepted around the world.

A wide variety of core combinations are manufactured as standard but please call us to discuss yourspecific needs. We are constantly increasing the standard range and will produce special designs forlow minimum order quantities.

275025415

Cables combining control, signal and power cores are now commonly used in industrial automation.Fine copper wire strands with high performance insulation and sheathing material make them idealfor regular flexing applications. A wide variety of core combinations are manufactured as standard butplease call us to discuss your specific needs. We are constantly increasing the standard range and willproduce special designs for low minimum order quantities.

HF-275 PUR Servo & Feedback Cables

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

129HF-275 PUR Servo & Feedback Cables ROBOTICS

Technical Information

Voltage Rating: EC 0.6/1kVPower cores Test V. 4000VUL/CSA 1000V Control cores Test V. 2000V

Temperature Rating: Flexing -30°C to +80°CBending Radius: Flexing 7.5 x cable diameter

These cables have UL and CSA approval as well as meetingthe requirements of DESINA®.

Construction - HF-275 PUR Servo

Power cores: very fine copper wire strands,polyolefin insulation with cores 1-3 black withwhite numbers, the fourth core is a green/yellowearth. Control cores: very fine copper wire strands,black TPE insulation with white numbers.Aluminium/polyester foil with a tinned copperbraid screen, around each pair there is a polyesterfoil wrap. Power & signal cores are twistedtogether with very short lay lengths. Syntheticfleece with overall tinned copper wire braid, lowfriction polyurethane sheath.

Part No. Cores x Weight O/Dmm² kg/km mm

275007403 4G 0.75 + 2 x (2 x 0.34) 172 11.1275010407 4G 1 + 2 x (2 x 0.75) 286 12.1275015405 4G 1.5 + 2 x (2 x 0.5) 342 12.2275015407 4G 1.5 + 2 x (2 x 0.75) 376 12.3275025415 4G 2.5 + 2 x (2 x 1.5) 447 15.1275040415 4G 4 + 2 x (2 x 1.5) 567 17.9275060415 4G 6 + 2 x (2 x 1.5) 664 18.2275100414 4G 10 + 2 x (2 x 1.5) 893 21.9275160415 4G 16 + 2 x (2 x 1.5) 1298 26.9275250415 4G 25 + 2 x (2 x 1.5) 1784 29.2275350415 4G 35 + 2 x (2 x 1.5) 2588 32.7275500425 4G 50 + 2 x (2 x 2.5) 3348 37.1275015215 4G 1.5 + (2 x 1.5) 233 12.1275025215 4G 2.5 + (2 x 1.5) 290 12.9275040215 4G 4 + (2 x 1.5) 376 14.5275060215 4G 6 + (2 x 1.5) 461 17.8275100215 4G 10 + (2 x 1.5) 739 20.6275160215 4G 16 + (2 x 1.5) 1123 23.6275250215 4G 25 + (2 x 1.5) 1451 28.1275350215 4G 35 + (2 x 1.5) 1919 32.1275500215 4G 50 + (2 x 1.5) 2852 35.3

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Silicone insulated conductors offer you an economical solution to many temperature related wiring problems. Capable ofworking at extremes as far apart as -50°C right up to +180°C, silicone insulated cables have grown substantially in popularity.

Flexibility is retained even at very low temperatures where conventional rubber or PVC cable would become brittle and crack.

At high temperatures the cable performs normally. In the case of a fire, the silicone changes to form an insulating layer of SiO2 which, provided there is no movement, will maintain cable integrity in the short term. This is important in the eventof a fire where equipment needs to be shut down, lighting maintained and alarm systems remain operational.

Silicone is relatively inert, that is to say it gives off minimal smoke or fumes when exposed to fire. Airports, hospitals, andother public buildings use silicone cables to wire alarm, lighting, and other essential services.

At high temperatures, applications include heating elements, lighting, manufacturing and food processing and for controlcircuits where heat is involved. At low temperatures silicone insulated cables are used in cold stores and refrigeration plantsfor lighting, portable equipment and motor feeds.

Silicone SiF, SiF-GL, SiD Singles

Technical Information

Voltage Rating: Working 300/500V Test 2000V

Temperature Rating: Flexing -25°C to +180°C Static -50°C to +180°C

SiD Static -50°C to +180°C

Bending Radius: Flexing 15 x cable diameter Static 7.5 x cable diameter

SiD Static 7.5 x cable diameter

Current Rating: Refer to IEE Regs Table 4F2A&B

Conductor Stranding: Flexible cables To IEC 60228 Class 5 & VDE 0295 Class 5

SiD To IEC 60228 Class 1 & VDE 0295 Class 1

Most of the silicone insulated cables on the following page are available from stock in standard pack sizes of

100m or 500m. For conductor sizes above 10mm2 the cable can be cut to the length you require. Other

voltages, strandings and approvals available on request.

Part No. mm² Weight O/Dkg/km mm

451002xx 0.25 5 1.9

451005xx 0.50 8 2.1

451007xx 0.75 11 2.4

451010xx 1.0 13 2.5

451015xx 1.5 18 2.8

451025xx 2.5 30 3.4

451040xx 4.0 48 4.2

451060xx 6.0 71 4.9

451100xx 10 120 6.7

451160xx 16 187 7.7

451250xx 25 289 9.8

Part No. mm² Weight O/Dkg/km mm

451350xx 35 399 10.9

451500xx 50 559 12.6

451700xx 70 766 14.6

451950xx 95 1032 17.5

451120xx 120 1285 18.7

451150xx 150 1565 20.8

451185xx 185 1915 23.7

451240xx 240 2550 26.9

451300xx 300 3190 30.1

451400xx 400 4130 36.3

451510xx 500 5210 40.3

Construction - SiF

Fine tinned copper wire strands, class 5, silicone insulation.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

130 HIGH TEMPERATURE Silicone Single Cores

SiF

SiD

SiF-GL

Part No. mm² Weight O/Dkg/km mm

441005xx 0.50 7 1.8

441007xx 0.75 10 2.0

441010xx 1.0 13 2.1

Part No. mm² Weight O/Dkg/km mm

441015xx 1.5 19 2.6

441025xx 2.5 31 3.2

441040xx 4.0 48 3.7

441060xx 6.0 68 4.2

Construction - SiD

Solid tinned copper wire strands, class 1, silicone insulation.

Construction - SiF-HT

Flexible tinned copper wire strands, class 5, silicone high voltage insulation.

Part No. mm² Weight O/Dkg/km mm

46100204 0.25 8 2.4

46100504 0.50 13 3.4

461007xx 0.75 16 3.6

461010xx 1.0 19 3.8

461015xx 1.5 24 4.3

461025xx 2.5 36 5.0

46104004 4.0 55 5.6

Part No. mm² Weight O/Dkg/km mm

46106004 6.0 80 6.2

46110004 10 130 8.2

46116004 16 200 9.6

46125004 25 310 12.0

46135004 35 420 13.5

46150004 50 580 15.5

46170004 70 790 18.0

46195004 95 1070 20.0

Construction - SiF-GL

Fine tinned copper wire strands, class 5, silicone insulation. Impregnated glass fibre braid. Various colours.

Part No. mm² Volts kV O/D mm Colour

45201000 1.0 7.5 5.0 Red

45501004 1.0 10 7.0 White

Construction - SiF-G-Si-HT

Flexible tinned copper wire strands, class 5, silicone high voltage insulation, glass fibre braid, blue

silicone sheath.

Part No. mm² Volts kV O/D mm Colour

45601000 1.0 16 8.0 Blue

45601500 1.5 16 8.5 Blue

To show the colour required please replace xx in the part number with:

00 Black 04 White 08 Orange

01 Blue 05 Grey 09 Yellow

02 Brown 06 Violet 10 Green

03 Red 07 Pink 99 Green/Yellow

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

131Silicone Single Cores HIGH TEMPERATURE

47101503

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Silicone insulated and sheathed multicore cables offer electrical engineers and specifiers a superb range of options. Ideallysuited to high or low temperature applications, these cables will work between -50°C and +180°C. When exposed to firethey produce minimal smoke or fumes and can be used to wire public buildings.

Options include a galvanised steel wire braid for mechanical protection or a tinned copper wire braid for screeningagainst EMI.

Applications within industry include plastic forming and moulding, packaging, food processing, refrigeration, furnacesand lighting.

Silicone SiHF, SiHFP, SiHF-C-Si Multicores

Technical Information

Voltage Rating: Working 300/500V Test 3000V

Temperature Rating: Flexing -25°C to +180°C Static -50°C to +180°C

Bending Radius SiHF: Flexing 15 x cable diameter Static 7.5 x cable diameter

Braided Cables: Flexing 20 x cable diameter Static 10 x cable diameter

Current Rating: Refer to IEE Regs Table 4F2A&B and 4F3A&B

Conductor Stranding: To IEC 60228 Class 5 & VDE 0295 Class 5

Construction - SiHF

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber outer sheath. (Some sizes available with black or white sheaths or an overall glass fibre braid).

Part No. Cores x O/Dmm² mm

47100702 2 x 0.75* 6.3

47100703 3 x 0.75* 7.0

47100704 4 x 0.75 7.7

47100705 5 x 0.75 8.5

47101002 2 x 1.0 7.0

47101003 3 x 1.0* 7.5

47101004 4 x 1.0 8.0

47101005 5 x 1.0 9.0

47101006 6 x 1.0 10.5

47101007 7 x 1.0 10.5

47101502 2 x 1.5 8.0

47101503 3 x 1.5* 8.5

47101504 4 x 1.5 9.0

47101505 5 x 1.5 10.0

47101506 6 x 1.5 10.5

47101507 7 x 1.5 10.5

47101508 8 x 1.5 12.0

47101510 10 x 1.5 14.5

47101512 12 x 1.5 16.0

47101516 16 x 1.5 19.5

47101518 18 x 1.5 20.0

Part No. Cores x O/Dmm² mm

47101520 20 x 1.5 21.0

47101524 24 x 1.5 23.0

47102502 2 x 2.5 9.5

47102503 3 x 2.5* 10.5

47102504 4 x 2.5 11.5

47102505 5 x 2.5 13.0

47102507 7 x 2.5 14.0

47102512 12 x 2.5 19.0

47104002 2 x 4.0 11.0

47104003 3 x 4.0 11.5

47104004 4 x 4.0 13.0

47104005 5 x 4.0 14.5

47104007 7 x 4.0 16.0

47106002 2 x 6.0 12.0

47106003 3 x 6.0 13.0

47106004 4 x 6.0 14.0

47106005 5 x 6.0 16.0

47106007 7 x 6.0 17.5

47110004 4 x 10 20.0

47116004 4 x 16 22.0

47125004 4 x 25 28.0

47135004 4 x 35 30.2

* Also available from stock with a black or white sheath

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

132 HIGH TEMPERATURE Silicone Multicores

48102504E

Construction - SiHFP

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber sheath. Glass fibre tape with an overall galvanised steel wire braid.

Construction - SiHF-C-Si

Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

rubber inner sheath or polyester tape. Tinned copper wire braid. Reddish brown silicone rubber sheath.

Part No. Cores x O/Dmm² mm

Steel Braid Armour48100702 2 x 0.75 8.0

48100703 3 x 0.75 8.5

48100704 4 x 0.75 9.5

48100705 5 x 0.75 10.0

48100706 6 x 0.75 11.0

48100707 7 x 0.75 11.0

48101002 2 x 1.0 8.5

48101003 3 x 1.0 9.0

48101004 4 x 1.0 10.0

48101005 5 x 1.0 10.5

48101006 6 x 1.0 11.5

48101007 7 x 1.0 11.5

48101502 2 x 1.5 9.0

48101503 3 x 1.5 9.5

48101504 4 x 1.5 11.0

48101505 5 x 1.5 12.0

48101506 6 x 1.5 13.0

48101507 7 x 1.5 13.0

48101508 8 x 1.5 14.5

48101510 10 x 1.5 16.0

48101512 12 x 1.5 17.5

48101516 16 x 1.5 21.0

Part No. Cores x O/Dmm² mm

48101518 18 x 1.5 21.5

48101520 20 x 1.5 22.5

48101524 24 x 1.5 24.5

48102502 2 x 2.5 11.0

48102503 3 x 2.5 12.0

48102504 4 x 2.5 13.0

48102505 5 x 2.5 14.5

48102507 7 x 2.5 15.5

48102512 12 x 2.5 20.5

48104002 2 x 4.0 12.5

48104003 3 x 4.0 13.0

48104004 4 x 4.0 14.5

48104005 5 x 4.0 16.0

48104007 7 x 4.0 17.5

48106002 2 x 6.0 13.5

48106003 3 x 6.0 14.5

48106004 4 x 6.0 15.5

48106005 5 x 6.0 17.5

48106007 7 x 6.0 19.0

48110004 4 x 10 21.5

48116004 4 x 16 23.5

48125004 4 x 25 30.0

Part No. Cores x O/Dmm² mm

Copper Braid Screen

49100702 2 x 0.75 9.1

49100703 3 x 0.75 9.5

49100704 4 x 0.75 10.1

49100705 5 x 0.75 10.7

49100707 7 x 0.75 11.6

49100712 12 x 0.75 14.8

49101002 2 x 1 9.4

49101003 3 x 1 9.7

49101004 4 x 1 10.3

49101005 5 x 1 11.2

49101007 7 x 1 11.9

Part No. Cores x O/Dmm² mm

49101502 2 x 1.5 10.6

49101503 3 x 1.5 11.0

49101504 4 x 1.5 11.9

49101505 5 x 1.5 13.2

49101507 7 x 1.5 14.2

49101512 12 x 1.5 18.0

49102502 2 x 2.5 12.0

49102503 3 x 2.5 12.9

49102504 4 x 2.5 14.2

49102505 5 x 2.5 15.4

49102507 7 x 2.5 16.8

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

133Silicone Multicores HIGH TEMPERATURE

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

These cables are manufactured to BS 3G 210 and operate up to +200°C or +250°C short term with silver plated copperconductors. Nickel plated conductor versions to work up to +260°C are available to special order. Other standards availableinclude American Mil, VDE, DIN and Lloyds.

PTFE is a remarkable material. It is unaffected by most oils, fuels and fluids. The high temperature range makes it resistantto damage from heat sources such as soldering irons or components.

Multicore and screened or braid armoured versions can also be manufactured in many sizes and styles.

Please note due to the manufacturing process this cable may be supplied in multiple lengths on a reel. For example 100mmay be made up of two or more lengths.

PTFE Single Cores BS 3G 210

BSG31419C04

BSG31819B01

Technical Information

Voltage Rating: Working Type A 300V Test: 2500V

Type B 600V Test: 3400V

Type C 1000V Test: 5000V

Temperature Rating: Static -55°C to +200°C Short term +250°C

Bending Radius: Static 6 x cable diameter

Conductor Material: Silver plated copper

Manufactured to BS 3G 210. See page 131 for colour code table.

Part No. AWG Stranding CSA Voltage Weight O/D mm mm mm2 Grade kg/km min max

BSG33007Axx 30 7/0.10 0.056 A 1.1 0.50 0.65

BSG32807Axx 28 7/0.12 0.089 A 1.4 0.56 0.71

BSG32807Bxx 28 7/0.12 0.089 B 2.1 0.76 0.96

BSG32607Axx 26 7/0.15 0.14 A 1.7 0.65 0.80

BSG32607Bxx 26 7/0.15 0.14 B 3.09 0.85 1.05

BSG32407Axx 24 7/0.20 0.22 A 3.04 0.80 0.95

BSG32407Bxx 24 7/0.20 0.22 B 3.89 1.00 1.20

BSG32407Cxx 24 7/0.20 0.22 C 4.64 1.26 1.52

BSG32219Axx 22 19/0.15 0.35 A 4.41 0.95 1.10

BSG32219Bxx 22 19/0.15 0.35 B 5.44 1.15 1.35

BSG32219Cxx 22 19/0.15 0.35 C 6.43 1.41 1.67

BSG32019Axx 20 19/0.20 0.61 A 7.19 1.20 1.35

BSG32019Bxx 20 19/0.20 0.61 B 8.43 1.40 1.60

BSG32019Cxx 20 19/0.20 0.61 C 9.08 1.66 1.92

BSG31819Bxx 18 19/0.25 0.96 B 12.1 1.65 1.85

BSG31819Cxx 18 19/0.25 0.96 C 14.3 1.91 2.17

BSG31619Cxx 16 19/0.30 1.23 C 16.5 2.16 2.46

BSG31419Cxx 14 19/0.36 1.94 C 23.9 2.34 2.74

BSG31219Cxx 12 19/0.45 3.08 C 38.5 2.91 3.31

BSG31037Cxx 10 37/0.40 4.65 C 56 3.46 3.86

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

134 HIGH TEMPERATURE PTFE Single Cores

76010000

Technical Information

Voltage Rating: Working 0.6/1kV

Test 5000V

Temperature Rating: Static -55°C to +260°C

Bending Radius: Static 10 x cable diameter

Conductor Stranding: To IEC 60228 class 5 flexible or finer

P-Temp-260 cables are designed to operate at conductor temperatures up to +260°C. The PTFEinsulation is covered by a layer of mica that is protected from abrasion or mechanical damage by animpregnated and varnished glass fibre braid. The cable is also capable of withstanding highertemperatures for short periods. This is a direct alternative to In-Temp 250 that used to bemanufactured by BICC.

The fine stranded nickel plated copper conductor provides flexibility during installation and routingwith substantially improved high temperature performance over tinned or plain copper.

Multicore versions can be made to your requirements normally with stainless steel or glass fibrebraids. Other types of PTFE insulated wires are also available with tinned, nickel, or silver platedconductors. Please ask for details.

P-Temp 260

*Current rating at +80°C ambient for conductor temperature of +250°C.

Up to 25mm2 held in stock.

We also hold stocks of some sizes of Unipren, Uniefglas, Uniminyvin, Uninyvin and Unitersil. Please ask for details.

Part No. CSA mm2 Stranding Weight kg/km O/D mm Currentx mm amps*

76001000 1.0 32 x 0.2 22 3.2 25

76001500 1.5 30 x 0.25 30 3.6 40

76002500 2.5 50 x 0.25 39 3.9 54

76004000 4.0 56 x 0.3 56 4.7 74

76006000 6.0 84 x 0.3 80 6.1 98

76010000 10 133 x 0.3 120 6.9 135

76016000 16 126 x 0.4 193 8.7 180

76025000 25 196 x 0.4 287 10.2 240

Construction

Fine nickel plated copper wire strands

to IEC 60228 Class 5 or finer. White

PTFE insulation. Mica tape, impregnated

and varnished glass fibre braid. Standard

colour white, other colours to special

order.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

135P-Temp 260 HIGH TEMPERATURE

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Pure nickel conductors offer excellent high temperature performance. The conductor can withstand temperatures up to+750°C. The high temperature glass insulation enables the nickel conductor to operate continuously at +600°C and forshort periods up to +750°C. Applications include furnaces, ovens, kilns and other extremely high temperature environments.

These cables can also be supplied in multicore versions with overall glass fibre or stainless steel braids for quantities as lowas 100m.

Higher voltages are available by special order. These include a mica tape in the cable construction. Please call if you have aspecific requirement.

G-Temp 600

Technical Information

Voltage Rating: Working 250V

Temperature Rating: Continuous +600°C Intermittent +750°C

Construction

Pure nickel strands, double glass yarn lapped,

impregnated, glass braided, double silicone varnished,

colour natural/white.

Nickel Crimp Lugs

Copper is not suitable for crimp lugs at very high temperatures due to its greater expansion rate. This can

result in nickel conductors simply dropping out.

We are able to offer high temperature stable crimp lugs that will work at over +800ºC suitable for use on

FSC G-Temp-600.

Part No. Nominal Stranding Lug Weight O/D Current ratings in CSA mm2 x mm Type kg/km mm Amps at +30°C Ambient.

Conductor Temp.+180°C +200° +250°C

78500516 0.50 16/0.2 A 9 2.0 5 6 7.5

78500724 0.75 24/0.2 A 11 2.3 6 7 9

78501032 1.0 32/0.2 A 16 2.5 9 9 10

78501530 1.5 30/0.25 B 22 2.7 15 16 17

78502550 2.5 50/0.25 B 32 3.3 21 22 23

78504056 4.0 56/0.3 C 46 3.9 26 28 29

78506084 6.0 84/0.3 C 59 5.2 31 33 34

Part No. Lug Conductor Size Stud Max Max Type Min Max Size Length Width

LUGN02/1/4 A 0.25mm2 1.0mm2 4mm 14.8 6.8

LUGN10/2/4 B 1.0mm2 2.5mm2 4mm 16.4 8.3

LUGN20/6/4 C 2.5mm2 6.0mm2 4mm 20.0 9.9

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

136 HIGH TEMPERATURE G-Temp 600

78504056

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

137318*TQ Heat Resistant Flex HIGH TEMPERATURE

57101504TQ

Technical Information

Voltage Rating: 300/500V

Conductor Stranding: Stranded. IEC 60228 class 5

Temperature Rating: -20°c to +85°c

Bending Radius: 6 x overall diameter

TQ flex is suitable for use on heat resistant applications ranging from lighting to central heatingsystems and immersion heaters. With colour coloured cores and rated at 85°C this cable is ideal asa power supply lead or a control cable where ambient temperatures exceed the working range ofstandard PVC cables. The EPR insulation and CSP jacket result in a highly flexible yet tough cable.

318*TQ Heat Resistant Flex

Motorised Valve Extension Cable

Part No. Cores x Weight kg/km O/D mmmm2

57100702TQ 2 x 0.75 65 6.6

57100703TQ 3 x 0.75 80 7.3

57100704TQ 4 x 0.75 95 7.8

57101002TQ 2 x 1.0 80 7.3

57101003TQ 3 x 1.0 95 7.8

57101004TQ 4 x 1.0 115 8.3

57101502TQ 2 x 1.5 120 8.8

57101503TQ 3 x 1.5 140 9.5

57101504TQ 4 x 1.5 175 10.5

57102502TQ 2 x 2.5 170 10.3

57102503TQ 3 x 2.5 200 11.0

57102504TQ 4 x 2.5 250 12.2

Part No. Cores x Weight kg/km O/D mmmm2

10000706MV 6 x 0.75 81 6.9

Construction

Stranded copper conductors to IEC

60228 Class 5, ethylene propylene

rubber (EPR, T) insulation colour coded.

Cores laid up, white chlorosulphonated

polyethylene (CSP, Q) jacket

Normally packed on 50m or 100m reels longer lengths may be available.

Colour Code:

Blue Brown Green/Yellow

Grey Orange White

Ideal for extending the cables on motorised valves on heating systems. Using heat resistant 90°C PVC thesecables make connecting up zoned systems simple. The colour code emulates the one used on popularmotorised valves.

Stranded copper conductors IEC 60228 class 5, PVC insulation, colour coded. Cores laid up, black heatresistant PVC jacket.

Construction

Fire resistant screened power cables provide EMI screening and circuit integrity in the event of a fire. They are ideal forapplications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to aminimum during normal operation and services must be maintained for evacuation during a fire situation. The cables meetIEC 60331 and are fire resistant for 3 hours at 750°C.

E30 System integrity cables to DIN 4102 part 12 are also available on request.

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Thermocouple cables are used to carry a signal from a thermocouple probe to the temperature measuring unit and aremade up of a positive and negative conductor (or leg) of different metals which are the same or similar as those in thethermocouple probe.

While commonly referred to as thermocouple cables, most cables are in fact ‘extension’ or ‘compensating’ cables.

Extension cables are manufactured with the same metals as the thermocouple probe. Due to the expense of extensioncables, compensating cables are often used in their place and provide accurate results over a more limited operating range.

As with any other instrumentation or measuring application it can be beneficial to have multiple numbers of pairs. Triplesare also available to meet specialist applications.

Interference (EMI) is also something to consider and screening, either individually around each pair or collectively around amulti pair is an option.

If the cable is likely to suffer mechanical damage or be buried in the ground armouring (SWA) is also available.

Cables installed in sensitive locations such as power stations Low Smoke Halogen Free thermocouple cables may be required.

Thermocouple Cables

GERMANDIN 43710.4

AMERICANANSI MC96.1

BRITISHBS 1843

EUROPEANBS 4937 Part 30Cable Type

KX

JX

TX

EX

NX

KCB

RCA/SCA

Compensation for Type K (was Vx)

Compensation for Type R or S

Extension Cables

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

+–

International Colour Codes for Thermocouple Cable Insulation

Compensating Cables

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

138 THERMOCOUPLE Thermocouple Cables

Part No. Conductor No. of Pairs Conductor Screening Insulation SheathType Size Type Material Material

Screened & Unscreened Single PairsTJXO0201 JX 1 7/0.2mm Overall Foil PVC PVCTJXU0201 JX 1 7/0.2mm Unscreened PVC PVCTJXO0401 JX 1 13/0.2mm Overall Foil PVC PVCTJXU0401 JX 1 13/0.2mm Unscreened PVC PVCTJXO0701 JX 1 23/0.2mm Overall Foil PVC PVCTJXU0701 JX 1 23/0.2mm Unscreened PVC PVCTJXO1501 JX 1 1/1.29mm Overall Foil PVC PVCTJXU1501 JX 1 1/1.29mm Unscreened PVC PVC

TKCO0201 KCB 1 7/0.2mm Overall Foil PVC PVCTKCU0201 KCB 1 7/0.2mm Unscreened PVC PVCTKCO0401 KCB 1 13/0.2mm Overall Foil PVC PVCTKCU0401 KCB 1 13/0.2mm Unscreened PVC PVCTKCO0701 KCB 1 23/0.2mm Overall Foil PVC PVCTKCU0701 KCB 1 23/0.2mm Unscreened PVC PVCTKCO1501 KCB 1 1/1.29mm Overall Foil PVC PVCTKCU1501 KCB 1 1/1.29mm Unscreened PVC PVC

TKXO0201 KX 1 7/0.2mm Overall Foil PVC PVCTKXU0201 KX 1 7/0.2mm Unscreened PVC PVCTKXO0401 KX 1 13/0.2mm Overall Foil PVC PVCTKXU0401 KX 1 13/0.2mm Unscreened PVC PVCTKXO0502H KX 1 16/0.2mm Overall Braid LSHF LSHFTKXO0701 KX 1 23/0.2mm Overall Foil PVC PVCTKXU0701 KX 1 23/0.2mm Unscreened PVC PVCTKXO1501 KX 1 1/1.29mm Overall Foil PVC PVCTKXU1501 KX 1 1/1.29mm Unscreened PVC PVC

TNXO0201 NX 1 7/0.2mm Overall Foil PVC PVCTNXU0201 NX 1 7/0.2mm Unscreened PVC PVCTNXO0401 NX 1 13/0.2mm Overall Foil PVC PVCTNXU0401 NX 1 13/0.2mm Unscreened PVC PVCTNXO0701 NX 1 23/0.2mm Overall Foil PVC PVCTNXU0701 NX 1 23/0.2mm Unscreened PVC PVCTNXO1501 NX 1 1/1.29mm Overall Foil PVC PVCTNXU1501 NX 1 1/1.29mm Unscreened PVC PVC

TRCO0201 RCA/SCA 1 7/0.2mm Overall Foil PVC PVCTRCU0201 RCA/SCA 1 7/0.2mm Unscreened PVC PVCTRCO0401 RCA/SCA 1 13/0.2mm Overall Foil PVC PVCTRCU0401 RCA/SCA 1 13/0.2mm Unscreened PVC PVCTRCO0701 RCA/SCA 1 23/0.2mm Overall Foil PVC PVCTRCU0701 RCA/SCA 1 23/0.2mm Unscreened PVC PVCTRCO1501 RCA/SCA 1 1/1.29mm Overall Foil PVC PVCTRCU1501 RCA/SCA 1 1/1.29mm Unscreened PVC PVC

TTXO0201 TX 1 7/0.2mm Overall Foil PVC PVCTTXU0201 TX 1 7/0.2mm Unscreened PVC PVCTTXO0401 TX 1 13/0.2mm Overall Foil PVC PVCTTXU0401 TX 1 13/0.2mm Unscreened PVC PVCTTXO0701 TX 1 23/0.2mm Overall Foil PVC PVCTTXU0701 TX 1 23/0.2mm Unscreened PVC PVCTTXO1501 TX 1 1/1.29mm Overall Foil PVC PVCTTXU1501 TX 1 1/1.29mm Unscreened PVC PVC

*Please note all the above cables are European Colour Coded.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

139Thermocouple Cables THERMOCOUPLE

Part No. Conductor No. of Conductor Screening Insulation Sheath Part No.Unarmoured Type Pairs Size mm2 Type Material Material Armoured

TJXI0502 JX 2 0.5 Ind & Overall Foil PVC PVC TJXI0502ATJXI0504 JX 4 0.5 Ind & Overall Foil PVC PVC TJXI0504ATJXI0506 JX 6 0.5 Ind & Overall Foil PVC PVC TJXI0506ATJXI0512 JX 12 0.5 Ind & Overall Foil PVC PVC TJXI0512ATJXI0516 JX 16 0.5 Ind & Overall Foil PVC PVC TJXI0516ATJXI0520 JX 20 0.5 Ind & Overall Foil PVC PVC TJXI0520ATJXI0524 JX 24 0.5 Ind & Overall Foil PVC PVC TJXI0524ATJXI0702 JX 2 0.75 Ind & Overall Foil PVC PVC TJXI0702ATJXI0704 JX 4 0.75 Ind & Overall Foil PVC PVC TJXI0704ATJXI0706 JX 6 0.75 Ind & Overall Foil PVC PVC TJXI0706ATJXI0712 JX 12 0.75 Ind & Overall Foil PVC PVC TJXI0712ATJXI0716 JX 16 0.75 Ind & Overall Foil PVC PVC TJXI0716ATJXI0720 JX 20 0.75 Ind & Overall Foil PVC PVC TJXI0720ATJXI0724 JX 24 0.75 Ind & Overall Foil PVC PVC TJXI0724A

TKXI0502 KX 2 0.5 Ind & Overall Foil PVC PVC TKXI0502ATKXI0504 KX 4 0.5 Ind & Overall Foil PVC PVC TKXI0504ATKXI0506 KX 6 0.5 Ind & Overall Foil PVC PVC TKXI0506ATKXI0512 KX 12 0.5 Ind & Overall Foil PVC PVC TKXI0512ATKXI0516 KX 16 0.5 Ind & Overall Foil PVC PVC TKXI0516ATKXI0520 KX 20 0.5 Ind & Overall Foil PVC PVC TKXI0520ATKXI0524 KX 24 0.5 Ind & Overall Foil PVC PVC TKXI0524ATKXI0702 KX 2 0.75 Ind & Overall Foil PVC PVC TKXI0702ATKXI0704 KX 4 0.75 Ind & Overall Foil PVC PVC TKXI0704ATKXI0706 KX 6 0.75 Ind & Overall Foil PVC PVC TKXI0706ATKXI0712 KX 12 0.75 Ind & Overall Foil PVC PVC TKXI0712ATKXI0716 KX 16 0.75 Ind & Overall Foil PVC PVC TKXI0716ATKXI0720 KX 20 0.75 Ind & Overall Foil PVC PVC TKXI0720ATKXI0724 KX 24 0.75 Ind & Overall Foil PVC PVC TKXI0724A

TKCI0502 KCB 2 0.5 Ind & Overall Foil PVC PVC TKCI0502ATKCI0504 KCB 4 0.5 Ind & Overall Foil PVC PVC TKCI0504ATKCI0506 KCB 6 0.5 Ind & Overall Foil PVC PVC TKCI0506ATKCI0512 KCB 12 0.5 Ind & Overall Foil PVC PVC TKCI0512ATKCI0516 KCB 16 0.5 Ind & Overall Foil PVC PVC TKCI0516ATKCI0520 KCB 20 0.5 Ind & Overall Foil PVC PVC TKCI0520ATKCI0524 KCB 24 0.5 Ind & Overall Foil PVC PVC TKCI0524ATKCI0702 KCB 2 0.75 Ind & Overall Foil PVC PVC TKCI0702ATKCI0704 KCB 4 0.75 Ind & Overall Foil PVC PVC TKCI0704ATKCI0706 KCB 6 0.75 Ind & Overall Foil PVC PVC TKCI0706ATKCI0712 KCB 12 0.75 Ind & Overall Foil PVC PVC TKCI0712ATKCI0716 KCB 16 0.75 Ind & Overall Foil PVC PVC TKCI0716ATKCI0720 KCB 20 0.75 Ind & Overall Foil PVC PVC TKCI0720ATKCI0724 KCB 24 0.75 Ind & Overall Foil PVC PVC TKCI0724A

TNXI0502 NX 2 0.5 Ind & Overall Foil PVC PVC TNXI0502ATNXI0504 NX 4 0.5 Ind & Overall Foil PVC PVC TNXI0504ATNXI0506 NX 6 0.5 Ind & Overall Foil PVC PVC TNXI0506ATNXI0512 NX 12 0.5 Ind & Overall Foil PVC PVC TNXI0512ATNXI0516 NX 16 0.5 Ind & Overall Foil PVC PVC TNXI0516ATNXI0520 NX 20 0.5 Ind & Overall Foil PVC PVC TNXI0520ATNXI0524 NX 24 0.5 Ind & Overall Foil PVC PVC TNXI0524ATNXI0702 NX 2 0.75 Ind & Overall Foil PVC PVC TNXI0702ATNXI0704 NX 4 0.75 Ind & Overall Foil PVC PVC TNXI0704ATNXI0706 NX 6 0.75 Ind & Overall Foil PVC PVC TNXI0706ATNXI0712 NX 12 0.75 Ind & Overall Foil PVC PVC TNXI0712ATNXI0716 NX 16 0.75 Ind & Overall Foil PVC PVC TNXI0716ATNXI0720 NX 20 0.75 Ind & Overall Foil PVC PVC TNXI0720ATNXI0724 NX 24 0.75 Ind & Overall Foil PVC PVC TNXI0724A

Individually and Collectively Foil Screened Multipairs, PVC, Armoured & Unarmoured

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

140 THERMOCOUPLE Thermocouple Cables

Construction - Armoured

Conductors insulated in PVC, cores laid up to form a pair, each pair

individually foil screened with drain wire, pairs laid up, overall foil screen

with drain wire, PVC bedding, steel wire armour, PVC outer sheath.

Construction - Unarmoured

Conductors insulated in PVC, cores laid up to form a pair,

each pair individually foil screened with drain wire, pairs laid

up, overall foil screen with drain wire, PVC outer sheath.

TTXO0505A

Part No. Conductor No. of Pairs Conductor Screening Insulation Sheath Part No.Unarmoured Type Size mm2 Type Material Material Armoured

TRCI0502 RCA/SCA 2 0.5 Ind & Overall Foil PVC PVC TRCI0502ATRCI0504 RCA/SCA 4 0.5 Ind & Overall Foil PVC PVC TRCI0504ATRCI0506 RCA/SCA 6 0.5 Ind & Overall Foil PVC PVC TRCI0506ATRCI0512 RCA/SCA 12 0.5 Ind & Overall Foil PVC PVC TRCI0512ATRCI0516 RCA/SCA 16 0.5 Ind & Overall Foil PVC PVC TRCI0516ATRCI0520 RCA/SCA 20 0.5 Ind & Overall Foil PVC PVC TRCI0520ATRCI0524 RCA/SCA 24 0.5 Ind & Overall Foil PVC PVC TRCI0524ATRCI0702 RCA/SCA 2 0.75 Ind & Overall Foil PVC PVC TRCI0702ATRCI0704 RCA/SCA 4 0.75 Ind & Overall Foil PVC PVC TRCI0704ATRCI0706 RCA/SCA 6 0.75 Ind & Overall Foil PVC PVC TRCI0706ATRCI0712 RCA/SCA 12 0.75 Ind & Overall Foil PVC PVC TRCI0712ATRCI0716 RCA/SCA 16 0.75 Ind & Overall Foil PVC PVC TRCI0716ATRCI0720 RCA/SCA 20 0.75 Ind & Overall Foil PVC PVC TRCI0720ATRCI0724 RCA/SCA 24 0.75 Ind & Overall Foil PVC PVC TRCI0724A

TTXI0502 TX 2 0.5 Ind & Overall Foil PVC PVC TTXI0502ATTXI0504 TX 4 0.5 Ind & Overall Foil PVC PVC TTXI0504ATTXI0506 TX 6 0.5 Ind & Overall Foil PVC PVC TTXI0506ATTXI0512 TX 12 0.5 Ind & Overall Foil PVC PVC TTXI0512ATTXI0516 TX 16 0.5 Ind & Overall Foil PVC PVC TTXI0516ATTXI0520 TX 20 0.5 Ind & Overall Foil PVC PVC TTXI0520ATTXI0524 TX 24 0.5 Ind & Overall Foil PVC PVC TTXI0524ATTXI0702 TX 2 0.75 Ind & Overall Foil PVC PVC TTXI0702ATTXI0704 TX 4 0.75 Ind & Overall Foil PVC PVC TTXI0704ATTXI0706 TX 6 0.75 Ind & Overall Foil PVC PVC TTXI0706ATTXI0712 TX 12 0.75 Ind & Overall Foil PVC PVC TTXI0712ATTXI0716 TX 16 0.75 Ind & Overall Foil PVC PVC TTXI0716ATTXI0720 TX 20 0.75 Ind & Overall Foil PVC PVC TTXI0720ATTXI0724 TX 24 0.75 Ind & Overall Foil PVC PVC TTXI0724A

Part No. Conductor No. of Pairs Conductor Screening Insulation Sheath Part No.Unarmoured Type Size mm2 Type Material Material Armoured

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

141Thermocouple Cables THERMOCOUPLE

Screened Single pairs, LSHF Fire Resistant, Armoured & Unarmoured

Construction - Armoured

Conductors stranded and mica taped, XLPE insulated, cores twisted toform a pair, overall foil screen with drain wire, LSHF bedding, steelwire armour, LSHF outer sheath.

Construction - Unarmoured

Conductors stranded and mica taped, XLPE insulated, cores

twisted to form a pair, overall foil screen with drain wire,

LSHF outer sheath.

*For Halogen Free versions please add an H to the end of the part number. These will generally be supplied withXLPE insulation and a LSHF sheath. Please note all the above cables are European Colour Coded

TJXO0501M JX 1 0.5 Overall Foil XLPE LSHF TJXO0501AMTJXO0701M JX 1 0.75 Overall Foil XLPE LSHF TJXO0701AM

TKCO0501M KCB 1 0.5 Overall Foil XLPE LSHF TKCO0501AMTKCO0701M KCB 1 0.75 Overall Foil XLPE LSHF TKCO0701AM

TKXO0501M KX 1 0.5 Overall Foil XLPE LSHF TKXO0501AMTKXO0701M KX 1 0.75 Overall Foil XLPE LSHF TKXO0701AM

TNXO0501M NX 1 0.5 Overall Foil XLPE LSHF TNXO0501AMTNXO0701M NX 1 0.75 Overall Foil XLPE LSHF TNXO0701AM

TRCO0501M RCA/SCA 1 0.5 Overall Foil XLPE LSHF TRCO0501AMTRCO0701M RCA/SCA 1 0.75 Overall Foil XLPE LSHF TRCO0701AM

TTXO0501M TX 1 0.5 Overall Foil XLPE LSHF TTXO0501AMTTXO0701M TX 1 0.75 Overall Foil XLPE LSHF TTXO0701AM

Spiral Cable

Part No. Coresx mm²

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Spiral Cables

Construction - PVC Spiral Cable

Fine copper wire strands. PVC insulation,colour coded cores, twisted together, PVC jacket.

Technical Information

Voltage Rating: Working 300/500V Temperature Rating: -5°C to +70°CApproximate Extension Ratio: 3.5:1

PVC Spirals88200702 2 x 0.7588200703 3 x 0.7588200704 4 x 0.7588200705 5 x 0.7588201002 2 x 1.0

Part No. Coresx mm²

88201003 3 x 1.088201004 4 x 1.088201005 5 x 1.088201502 2 x 1.588201503 3 x 1.588201504 4 x 1.5

Part No. Coresx mm²

88201505 5 x 1.588202502 2 x 2.588202503 3 x 2.588202504 4 x 2.588202505 5 x 2.5

Part No. Cores x mm²

Construction: PUR Screened Spiral Cable

Fine copper wire strands of class 5 or 6. TPE insulation, colour coded cores, twistedtogether, overall tinned copper wire braid,PUR jacket.

Technical Information

Voltage Rating: Working ≤0.25mm² 100V≥ 0.5mm² 300V

Temperature Rating: -25°C to +80°CApproximate Extension Ratio: 4:1

PUR Screened Spirals88300102 2 x 0.1488300103 3 x 0.1488300104 4 x 0.1488300105 5 x 0.1488300106 6 x 0.1488300107 7 x 0.1488300108 8 x 0.1488300112 12 x 0.1488300118 18 x 0.1488300125 25 x 0.14

Part No. Coresx mm²

88300202 2 x 0.2588300203 3 x 0.2588300204 4 x 0.2588300205 5 x 0.2588300206 6 x 0.2588300207 7 x 0.2588300208 8 x 0.2588300212 12 x 0.2588300218 18 x 0.2588300225 25 x 0.25

Part No. Coresx mm²

88300503 3 x 0.588300504 4 x 0.588300505 5 x 0.588300506 6 x 0.588300507 7 x 0.588300508 8 x 0.588300512 12 x 0.588300518 18 x 0.588300525 25 x 0.5

FSC offers both signal and power versions of retractable spiral cables. The variations in conductor size, insulation andsheath materials are enormous. Having decided on the conductor size and the number of cores it is important to choosethe insulation and sheath materials most suitable for the task. The retracted length of the spiral can be made to yourrequirements up to 5m.

Although once popular, PVC is now giving way to polyurethane as a sheathing material which has a much better memory.Rubber is still popular with hytral used for the highest performance cables. The sizes and types shown on the page oppositeare a small selection of the spiral cables offered. There are many other sheathing, insulation materials and voltage ratingsas well as screened versions available. Please call with your exact requirement.

These cables are manufactured to order, to meet your needs precisely. You can specify tail lengths (the straights at eitherend). The standard length is at least 150mm and they can be supplied in line or at right angles to the coil.

Delivery is normally around 10 working days but please check when ordering. Many other core combinations are available.Please call to discuss your requirements.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

142 SPIRAL Spiral Cables

Construction: PUR Spiral Cable

Fine copper wire strands of class 5 or 6. TPE or EPR insulation,colour coded cores, twisted together, PUR jacket.

Technical Information

Voltage Rating: Working 300/500V Temperature Rating: -25°C to +85°CApproximate Extension Ratio: 4:1

Part No. Coresx mm²

PUR Unscreened Spirals88100102 2 x 0.1488100103 3 x 0.1488100104 4 x 0.1488100105 5 x 0.1488100106 6 x 0.1488100107 7 x 0.1488100108 8 x 0.1488100110 10 x 0.1488100112 12 x 0.1488100116 16 x 0.1488100125 25 x 0.1488100202 2 x 0.2588100203 3 x 0.2588100204 4 x 0.25

Part No. Cores x mm²

88100205 5 x 0.2588100206 6 x 0.2588100207 7 x 0.2588100208 8 x 0.2588100210 10 x 0.2588100212 12 x 0.2588100216 16 x 0.2588100225 25 x 0.2588100502 2 x 0.588100503 3 x 0.588100504 4 x 0.588100505 5 x 0.588100506 6 x 0.588100507 7 x 0.588100508 8 x 0.5

Part No. Coresx mm²

88100510 10 x 0.588100512 12 x 0.588100516 16 x 0.588100525 25 x 0.588100702 2 x 0.7588100703 3 x 0.7588100704 4 x 0.7588100705 5 x 0.7588101002 2 x 1.088101003 3 x 1.088101004 4 x 1.088101005 5 x 1.088101007 7 x 1.088101012 12 x 1.088101502 2 x 1.5

Part No. Coresx mm²

88101503 3 x 1.588101504 4 x 1.588101505 5 x 1.588101507 7 x 1.588101512 12 x 1.588102503 3 x 2.588102504 4 x 2.588102505 5 x 2.588104004 4 x 4.088104005 5 x 4.088106004 4 x 6.0

Construction: Rubber TPE Spiral Cable

Fine copper wire strands of class 5. Special PVCinsulation, colour coded cores, twisted together,black TPE synthetic rubber jacket.

Technical Information

Voltage Rating: Working 300/500V Temperature Rating: -15°C to +80°CApproximate Extension Ratio: 5:1

Part No. Cores x mm²

Rubber TPE Spirals88000702 2 x 0.7588000703 3 x 0.7588000704 4 x 0.7588000705 5 x 0.7588000707 7 x 0.7588000710 10 x 0.7588000715 15 x 0.7588001002 2 x 1.088001003 3 x 1.088001004 4 x 1.0

Part No. Coresx mm²

88001005 5 x 1.088001007 7 x 1.088001010 10 x 1.088001015 15 x 1.088001502 2 x 1.588001503 3 x 1.588001504 4 x 1.588001505 5 x 1.588001507 7 x 1.588001510 10 x 1.588001515 15 x 1.5

Part No. Coresx mm²

88002502 2 x 2.588002503 3 x 2.588002504 4 x 2.588002505 5 x 2.588002507 7 x 2.588004003 3 x 4.088004004 4 x 4.088004005 5 x 4.088006003 3 x 6.088006004 4 x 6.0

DS

DC

LC

LE

ST

RARA

ST

ST Length of straight tail

Length of tailat right angles

Length extended

Length closed

Diameterof spiral

Diameterof cableRA

LE

LC

DS

DC

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

143Spiral Cables SPIRAL

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

FSC offers a range of high quality industrial cable glands manufactured in nylon and metal to meet industry requirements. Metal glands are available in a plain brass or with nickel plating. All the glands have at least one rubber seal to provideenvironmental protection and an IP (Ingress Protection) rating. To achieve the IP rating shown an additional washer may berequired if the enclosure or panel is not threaded. If you are not sure please ask at time of enquiry.

We can also supply gland kits complete with accessories, please add a K to the end of the part number. Aluminium glands forterminating AWA type armours and stainless steel glands for specialist applications are also available.

Industrial Glands

CW

Part No. Description Thread Cable O/D Steel ISO (mm) Range (mm) Locknut

GA2M20SSN A2 20S/16 20 3.1 - 8.7 GLSM20GA2M20SN A2 20S 20 6.1 - 11.7 GLSM20GA2M20N A2 20 20 6.5 - 14.0 GLSM20GA2M25N A2 25 25 11.1 - 20.0 GLSM25GA2M32N A2 32 32 17.0 - 26.3 GLSM32GA2M40N A2 40 40 23.5 - 32.2 GLSM40GA2M50SN A2 50S 50 31.0 - 38.2 GLSM50GA2M50N A2 50 50 35.6 - 44.1 GLSM50GA2M63SN A2 63S 63 41.5 - 50.0 GLSM63GA2M63N A2 63 63 47.2 - 56.0 GLSM63GA2M75SN A2 75S 75 54.0 - 62.0 GLSM75GA2M75N A2 75 75 61.1 - 68.0 GLSM75GA2M90N A2 90 90 66.6 - 79.4 GLSM90GA2M100N A2 100 100 76.0 - 91.0 GLSM100GA2M115N A2 115 115 86.0 - 98.0 GLSM115GA2M130N A2 130 130 97.0 - 115.0 GLSM130

A2 nickel plated brass glands for unarmoured cables IP68 rated indoor/outdoor glands with a single rubber seal on the cable sheath. -60°C to +150°C.Sometimes referred to as stuffing glands they are ideal for unarmoured or flexible cables.

Part No. Description Thread Cable Cable SteelISO Bedding O/D Range Locknut

(mm) Diameter (mm)

GCWM20SSN CW 20S/16 20 8.7 6.1 - 11.5 GLSM20 GCWM20SN CW 20S 20 11.7 9.5 - 15.9 GLSM20 GCWM20N CW 20 20 14.0 12.5 - 20.9 GLSM20 GCWM25SN CW 25S 25 19.9 14.0 - 22.0 GLSM25GCWM25N CW 25 25 20.0 18.2 - 26.2 GLSM25GCWM32N CW 32 32 26.3 23.7 - 33.9 GLSM32GCWM40N CW 40 40 32.2 27.9 - 40.4 GLSM40GCWM50SN CW 50S 50 38.2 35.2 - 46.7 GLSM50GCWM50N CW 50 50 44.1 40.4 - 53.1 GLSM50GCWM63SN CW 63S 63 50.0 45.6 - 59.4 GLSM63GCWM63N CW 63 63 56.0 54.6 - 65.9 GLSM63GCWM75S CW 75S 75 62.0 59.0 - 72.1 GLSM75GCWM75N CW 75 75 68.0 66.7 - 78.5 GLSM75GCWM90N CW 90 90 80.0 76.2 - 90.4 GLSM90GCWM100N CW 100 100 91.0 89.1 - 101.5 GLSM100GCWM115N CW 115 115 98.0 101.3 - 110.3 GLSM115GCWM130N CW 130 130 115.0 114.0 - 123.3 GLSM130

CW nickel plated brass glands for SWA armoured cables Ideal for anchoring the steel wire armour (SWA) on power, data and instrumentation cables IP66 ratedindoor/outdoor glands that terminate the armour and provide a seal on the outer sheath of the cable. -60°C to +150°C.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

144 GLANDS Plastic & Brass Industrial

A2

E1W

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

Always use a gland with a maximum size closest to the diameter of the cable so the gland only has to compress a minimalamount.

Reducers, enlargers and convertors are available to alter the gland thread size. These can be supplied in metal or plastic tofit pre threaded enclosures or equipment. Adaptors are also available to change one type of thread to another. Combinationsinclude ISO metric, NPT and PG.

Industrial Glands

Part No. Description Thread Cable Cable SteelISO Bedding O/D Range Locknut

(mm) Diameter (mm)

GCXM20SSN CX 20S/16 20 8.7 6.1 - 11.5 GLSM20 GCXM20SN CX 20S 20 11.7 9.5 - 15.9 GLSM20 GCXM20N CX 20 20 14.0 12.5 - 20.9 GLSM20 GCXM25SN CX 25S 25 19.9 14.0 - 22.0 GLSM25GCXM25N CX 25 25 20.0 18.2 - 26.2 GLSM25GCXM32N CX 32 32 26.3 23.7 - 33.9 GLSM32GCXM40N CX 40 40 32.2 27.9 - 40.4 GLSM40GCXM50SN CX 50S 50 38.2 35.2 - 46.7 GLSM50GCXM50N CX 50 50 44.1 40.4 - 53.1 GLSM50GCXM63SN CX 63S 63 50.0 45.6 - 59.4 GLSM63GCXM63N CX 63 63 56.0 54.6 - 65.9 GLSM63GCXM75SN CX 75S 75 62.0 59.0 - 72.1 GLSM75GCXM75N CX 75 75 68.0 66.7 - 78.5 GLSM75GCXM90N CX 90 90 80.0 76.2 - 90.4 GLSM90GCXM100N CX 100 100 91.0 89.1 - 101.5 GLSM100GCXM115N CX 115 115 98.0 101.3 - 110.3 GLSM115GCXM130N CX 130 130 115.0 114.0 - 123.3 GLSM130

CX nickel plated glands for braided cables and steel tape armoured cables Designed to secure braid armours and braid screens they can also be used for steel tape armours on fibreoptic and instrumentation cables. IP66 rated indoor/outdoor glands that terminate the braid or tape andprovide a seal on the cable sheath. -60°C to +150°C.

Part No. Description Thread Cable Cable SteelISO Bedding O/D Range Locknut

(mm) Diameter (mm)

GE1WM20SSN E1W 20S/16 20 3.1-8.7 6.1-11.5 GLSM20 GE1WM20SN E1W 20S 20 6.1-11.7 9.5-15.9 GLSM20 GE1WM20N E1W 20 20 6.5-14.0 12.5-20.9 GLSM20 GE1WM25SN E1W 25S 25 11.1-19.9 14.0-22.0 GLSM25GE1WM25N E1W 25 25 11.1-20.0 18.2-26.2 GLSM25GE1WM32N E1W 32 32 17.0-26.3 23.7-33.9 GLSM32GE1WM40N E1W 40 40 22.0-32.2 27.9-40.4 GLSM40GE1WM50SN E1W 50S 50 29.5-38.2 35.2-46.7 GLSM50GE1WM50N E1W 50 50 35.6-44.1 40.4-53.1 GLSM50GE1WM63SN E1W 63S 63 40.1-50.0 45.6-59.4 GLSM63GE1WM63N E1W 63 63 47.2-56.0 54.6-65.9 GLSM63GE1WM75SN E1W 75S 75 52.8-62.0 59.0-72.1 GLSM75GE1WM75N E1W 75 75 59.1-68.0 66.7-78.5 GLSM75GE1WM90N E1W 90 90 66.6-80.0 76.2-90.4 GLSM90GE1WM100N E1W 100 100 76.0-91.0 89.1-101.5 GLSM100GE1WM115N E1W 115 115 86.0-98.0 101.3-110.3 GLSM115GE1WM130N E1W 130 130 97.0- 115.0 114.0-123.3 GLSM130

E1W dual seal nickel plated brass glands for SWA armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outersheath of the cable. -60°C to +150°C.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

145Plastic & Brass Industrial GLANDS

CX

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

If the gland type you require is not shown or you need a specialist gland for a bespoke application please contact us and wewill do our best to help you.

Industrial Glands

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

IP68 rated glands which seal onto the outer sheath. Ideal for use on flexible cables and screened cableswhere the screen it terminated inside the enclosure. If the gland is not being used on a threadedenclosure you may require a locknut which is sold separately. -30°C to +80°C.

Nylon Cable Glands for unarmoured cables

Part No. Description Thread Cable Cable SteelISO Bedding O/D Range Locknut

(mm) Diameter (mm)

GE1XM20SS E1X 20S/16 20 3.1 -8.7 6.1 -11.5 GLSM20

GE1XM20S E1X 20S 20 6.1 -11.7 9.5 -15.9 GLSM20

GE1XM20 E1X 20 20 6.5 -14.0 12.5 -20.9 GLSM20

GE1XM25S E1X 25S 25 11.1 -19.9 14.0 -22.0 GLSM25

GE1XM25 E1X 25 25 11.1 -20.0 18.2 -26.2 GLSM25

GE1XM32 E1X 32 32 17.0 -26.3 23.7 -33.9 GLSM32

GE1XM40 E1X 40 40 22.0 -32.2 27.9 -40.4 GLSM40

GE1XM50S E1X 50S 50 29.5 -38.2 35.2 -46.7 GLSM50

GE1XM50 E1X 50 50 35.6 -44.1 40.4 -53.1 GLSM50

GE1XM63S E1X 63S 63 40.1 -50.0 45.6 -59.4 GLSM63

GE1XM63 E1X 63 63 47.2 -56.0 54.6 -65.9 GLSM63

GE1XM75S E1X 75S 75 52.8 -62.0 59.0 -72.1 GLSM75

GE1XM75 E1X 75 75 59.1 -68.0 66.7 -78.5 GLSM75

GE1XM90 E1X 90 90 66.6 -80.0 76.2 -90.4 GLSM90

GE1XM100 E1X 100 100 76.0 - 91.0 89.1 -101.5 GLSM100

GE1XM115 E1X 115 115 86.0 - 98.0 101.3 -110.3 GLSM115

GE1XM130 E1X 130 130 97.0 - 115.0 114.0 -123.3 GLSM130

E1X dual seal nickel plated brass glands for braid armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outersheath of the cable. -60°C to +150°C.

Part No. Size Spanner Cable O/D LocknutSize Range (mm)

Part No. Size Spanner Cable O/D LocknutSize Range (mm)

GNM12x M12 15 3.0-6.5 GLNM12x

GNM16x M16 19 5.0-10.0 GLNM16x

GNM20x M20 24 6.0-12.0 GLNM20x

GNM25x M25 33 9.0-17.0 GLNM25x

GNM32x M32 42 18.0-25.0 GLNM32x

GNM40x M40 53 22.0-32.0 GLNM40x

GNM50x M50 60 30.0-38.0 GLNM50x

GNM63x M63 68 34.0-42.0 GLNM63x

GNP07x PG7 15 3.0-6.5 GLP07x

GNP09x PG9 19 4.0-8.0 GLP09x

GNP11x PG11 22 5.0-10.0 GLP11x

GNP13x PG13 24 6.0-12.0 GLP13x

GNP16x PG16 27 10.0-14.0 GLP16x

GNP21x PG21 33 13.0-18.0 GLP21x

GNP29x PG29 42 18.0-25.0 GLP29x

GNP36x PG36 53 22.0-32.0 GLP36x

GNP42x PG42 60 30.0-38.0 GLP42x

GNP48x PG48 65 34.0-44.0 GLP48x

ISO Metric Thread German PG Thread

E1X

To show the colour required please replace x in the part number with:

0 Black 3 Red 4 White 5 Grey - RAL 7001 6 Light Grey - RAL 7035

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

146 GLANDS Plastic & Brass Industrial

NylonGland

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

147Jointing Kits GLANDS

???N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331)

A range of jointing kits are provided to enable the safe connection of cables either above or below ground. Suitable for use ondata, signal, telephone or power cables with or without armour, the conductors are first jointed using the appropriate connectorthen the outer shell is put in place and filled with a two part polyurethane resin.

The resin is supplied in a fully enclosed easy-mixing sachet for a simple, clean application.

These joints will last for years in either fixed or permanent installations.

Please note the jointing boxes below include the shells, resin and armour bonds. They do not include the conductor jointswhich will vary depending on the type of cable and need to be ordered separately. Crimps are also available for telephonecables and solid conductor data cables.

Jointing Kits

Part No. Cable O/D Internal Length Internal WidthRange (mm) (mm) (mm)

JK1 12 -26 185 35JK2 14 -32 245 48JK3 23 -39 325 52JK4 28 -50 375 68

Part No. Cable O/D Internal Length Internal WidthRange (mm) (mm) (mm)

JK5 32 -58 520 102JK6 45 -75 705 124JK7 40 -89 862 140JK8 57 -95 900 150

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC60331) Crimp lug for jointing two power cable conductors. Crimps are sold singularly so you need to order the correct number to suit

the cable you are jointing. Armour bonds are included for jointing SWA cables.

Crimp Lugs

Conductor Size Lug Part No.mm²

1.5 LUC0152.5 LUC0254.0 LUC0406.0 LUC060

Conductor Size Lug Part No.mm²

10 LUC10016 LUC16025 LUC25035 LUC350

Conductor Size Lug Part No.mm²

50 LUC50070 LUC70095 LUC950120 LUC120

Connectors for Solid Telecom Conductors

Crimp Lugs

Part No. Description Max. Length Width Open Closed Conductor Dia. Max. Dia. incNo. Wires mm mm Height mm Height mm Min. & Max. mm Insulation mm

8A/1 8A/1 connector 2 14.85 9.75 9.00 6.40 0.4 – 0.9 2.108B 8B connector 3 16.25 12.65 9.00 6.40 0.4 – 0.9 2.1011A 11A connector 2 12.60 12.50 9.30 5.80 0.4 – 0.9 2.06

YTC5

YCS1

YTS1

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

148 TOOLS

High quality tools needn’t cost a fortune. Designed with the operator in mind and a long service life you can be confidentthe FSC range of tools will do the job. Covering crimping, cutting, stripping and installation, these tools have been chosenfor their ease of use and cost effectiveness. Try a single piece and if you agree that they are great value for money, enjoythe quantity discounts offered on multiple items.

Coax Connector Tools

A range of well made and competitively priced tools to crimp most types of connectors from BNC to N-Typeonto various coaxial cables.

Cable Jacket Strippers

A safe and quick way of scoring and stripping sheaths and jackets from SWA, LSHF or PVC mains orcontrol cables. Blades are adjustable for depth and direction. Metal cutting parts are used to reducewear and replacement blades are available to ensure a long service life.

BNC Removal Tools

Allows easy installation and removal of terminated coaxial leads from panels where it can involveworking in very tight spaces with large numbers of leads.

Tools

Part No. Description Handle Colour

YTC1 Crimp Tool 1 for RG58, RG59, RG62, RG59 Mini & PSF 1/3 Yellow

YTC2 Crimp Tool 2 for RG59, CT100, CT125 Green

YTC3 Crimp Tool 3 for RG11, RG213 & CT125 (BNC only) Blue

YTC10 Crimp Tool 10 for Firetuf Coax Cable 387FTC5903 Blue

Part No. Description Handle Colour

YTC5 Crimp tool 5 for RJ45 connectors Orange

Part No. Description

YTS1 Cable Stripper for RG58 & RG59

YTS2 Cable Stripper for Cat 5E & Cat 6

Part No. Description

YCS1 Adjustable Cable Slitter for O/D 4.5mm to 25mm

YCS1-Spare Spare Blade for Adjustable Cable Slitter (YCS1)

Part No. Description

YRT1 Removal Tool for BNC connectors 12” long

YRT2 Removal Tool for F-Type connectors 12” long

RJ45 Tools

Designed to crimp RJ45 connectors up to 10 pin onto solid or stranded conductors. Suitable for mostpopular RJ45 connectors.

YTC1

YRT1

YFOS

YCC162

YCC350

YCC600

YCCT300

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

149TOOLS

Kevlar Scissors

Designed to cut kevlar, polyaramid or strainer elements in fibre optic cables, these scissors are alsoideal to neatly cut copper wire braids on coax or screened data and control cables.

Part No. Description Handle Colour

YFOS Scissors for cutting kevlar, polyaramid or braids Black

Hand Cable Cutters

A range of strong yet competitively priced cutters to meet most electricians’ needs. These largeheavy duty cable cutters are widely used by wholesalers and cable distributors as well as contractorsand installers.

Part No. Description Cutting Range Overall Length mm

YCC162 Hand Cable Cutters Up to 6mm² 160

YCC235 Hand Cable Cutters Up to 35mm² 235

Part No. Description Cutting Range Cu or Al Overall Length mm

YCC350 Hand Cable Cutters Up to 120mm² 350

YCC540 Hand Cable Cutters Up to 240mm² 540

YCC700 Hand Cable Cutters Up to 500mm² 700

Cable Cutters - Cast Aluminium Handles

Lightweight yet tough, these cable cutters are ideal where large quantities of cuts are carried out.They are particularly suitable for cable distributors and railway, telecoms and strip-out contractors.

Part No. Description Cutting Range Cu or Al Overall Length mm

YCC320 Hand Cable Cutters Up to 120mm² 320

YCC600 Hand Cable Cutters Up to 240mm² 600

YCC810 Hand Cable Cutters Up to 500mm² 810

Cable Cutters - Telescopic Handles

Tough yet compact, these cutters with pull out and twist-to-lock telescopic handles are great forkeeping in a tool box. The extending handles also give extra leverage when cutting large cables.

Cutting Range refers to the total cross-sectional area of the conductors i.e. 1 x 120mm2 or 4 x 25mm2. All dimensions are approximate.

Hand cutters should never be forced or have the handles extended to give extra leverage.

Part No. Description Cutting Range Cu or Al Overall Length mm

YCCT300 Hand Cable Cutters Up to 120mm² 300 – 400

YCCT415 Hand Cable Cutters Up to 240mm² 415 - 565

Cable Cutters - Tubular Steel Handles

Compact low cost cutters ideal for site or stockists. Suitable for flexible, data, telecoms and other unarmoured cables.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

150 TOOLS

Hydraulic Tools for Cutting

Hydraulic cutters are an easy way of cutting large or medium sized copper or aluminium cables. Theyare particularly useful when working in confined spaces such as panels, transformers or trencheswhere there may not be sufficient room to use conventional cutters or where the physical forcerequired to cut the cable is too great.

Extensively used on site where cutting large armoured cables safely and with minimal effort is required.

Hand Operated – Hydraulic Cutters

These hydraulic cutters feature hardened blades to cut most types of telecom, power (including SWA)and large flexible cables. Competitively priced and complete with a steel case these cutters are idealfor use on site.

Part No. Description Cutting range Cutting LengthO/D mm Force (Tonnes) mm

YHC600 Hydraulic Cutters 40 12 600

YHC630 Hydraulic Cutters 45 12 630

*YHC600 is also suitable for cutting steel rope up to 28mm in diameter.

Hand Operated – Hydraulic Cutters

Features a flip-open cutter head for quick and easy cutting, and a rotatable head for cutting at anyangle. The cutter has a two stage hydraulic action for faster cutting and either automatic or manualpressure release at the end or during the cut cycle.

Part No. Description Cutting range Cutting LengthO/D mm Force mm

YHC560 Hydraulic Cutters 45 60 KN 560

YHC680 Hydraulic Cutters 85 60 KN 680

Hydraulic Cutters Heads

Cutting heads are ideal for either working in confined spaces or mounting on equipment or machinery.They can be powered either by hand or foot operated hydraulic pumps or a motorised version linkedby a flexible hose.

Part No. Description Cutting range Cutting LengthO/D mm Force (Tonnes) mm

YHH340 Hydraulic Cutters 45 12 340

YHH515 Hydraulic Cutters 75 7.5 515

*Please note, all cutters are designed to cut copper and aluminium conductors with most types of insulationor sheath. Some will also cut SWA (armoured cable) and steel tape armour but this will blunt the cuttingsurface more quickly. Hand cutters should never be forced or have the handles extended to give extra leverage.

All dimensions are approximate and colours may vary.

YHC600

YHC560

YHH340

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

151TOOLS

Hydraulic Power Pumps

Designed to work with hydraulic cutting heads YHH340 & YHH515 the pump will also powercrimpers, benders, rebar cutters and hole punches.

Part No. Description Max. Output Max. Output SizePressure (Low) Pressure (High) mm

YHP510 Hand Hydraulic Power Pumps 20kg/cm² 700kg/cm² 510 x 150 x 200

YHP450 Foot Hydraulic Power Pumps 20kg/cm² 700kg/cm² 450 x 150 x 200

Hand Operated - Hydraulic Tools for Crimping

High quality crimpers ideal for rental and hire companies due to their long service life. They are packedin storage cases with a full set of hardened crimping dies to suit. Quick pressure release can beoperated at any stage of operation. Rotatable head allows work in confined spaces and both modelsare suitable for inline crimps. YHT560 has a C shaped crimping head for open access.

Part No. Description Crimping range Crimping LengthForce mm

YHT370 Hydraulic Crimp Tool 10 – 150mm² 6 370

YHT560 Hydraulic Crimp Tool 16 – 400mm² 13 560

Standard round cutters included, square cutters are also available to order.

Hand Operated - Hydraulic Tools for Crimping

Cost effective crimpers that are easy to operate and ideal for site work. They are packed in a storagebox complete with interchangable hexagon crimping dies to cover the crimping range. Fixedcrimping head.

Part No. Description Crimping Range Length mm

YHT425 Hydraulic Crimp Tool 10 – 120mm² 425

Part No. Mild Steel ≤ 3mm Mild Steel ≤ 2mm Stainless Steel ≤ 2mm

Punching Range

YHP310 16.5 – 60.5 16.5 – 115.5 16.5 – 60.5

YHP510

YHT425

YHT370

Hand Operated Hydraulic Hole Punch

Compact light weight hole punch for use on panels, trunking and cabinets as well as other mild orstainless steel sheet. Rotatable head allows for comfortable working.

YHP310

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant(IEC 60331)

You specify, we supply – with quantities as low as 100 metres in some cases. Theoptions outlined on these pages are the main variations and can be combined in any way to meet your particular specifications.

Talk to us about cost-effective solutions for applications that are not mentionedhere.

Custom-made Cables

Many cables can be supplied in a range of jacket colours.

Existing cables can be coloured either by dyeing if they are PVC, or otherwiseoversheathed to match an existing colour scheme or for identifying circuits, forexample alarm data wiring.

Talk to us about the options available.

Special Colours

There is an increasing need for cable to be manufactured to customers’ specificrequirements. This can be as basic as a special colour code or jacket colour, rightthrough to cables containing mixed core sizes (as well as a coax), with various levelsof screening or armouring.

At FSC we have considerable experience of ensuring that ‘specials’ meet yourdesign criteria.

Composite and Special Cables

In situations where the cable runs outside or through ducts polyethylene sheathingis the ideal solution. This material is tough, water-resistant and has natural lowfriction, making it easy to pull through ducts. It is also ideal for clipping to theoutside of buildings offering good resistance to sunlight.

Two types of polyethylene are used, Low Density (LDPE) and High Density (HDPE).LDPE offers reasonable flexibility and mechanical protection. It is particularly suitedto small data cables, while HDPE is much stiffer and is normally used for largercables where no flexibility is required. Even quantities as low as 100m can beoversheathed, which allows you to use the same basic cable throughout aninstallation but with the added protection needed.

Outdoor and Duct Grade Sheaths

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

152 SPECIAL MANUFACTURE

For added protection cables can be braided with a galvanised steel wire braid(GSWB) or heavy tinned copper wire.

Braiding maintains a degree of flexibility, which may be important during installationor if the equipment needs to be moved for maintenance or is subject to vibration.

Braiding

Cables can be printed with your company name, telephone number or anidentification code such as a batch or location number.

Printed Sheaths

For most jobs time is money and you cannot afford to make a mistake. To reduceinstallation time and cost many system manufactures are now operating a plug andplay design allowing the installer to simply plug pre-manufactured leads intomodules for right first time termination.

To meet these growing demands we are able to supply many of the coax, data andinstrumentation cables listed in the catalogue as pre-terminated leads to save youtime and money.

All we need to know is the length and the connector type you require - we will dothe rest.

Custom Made Leads & Assemblies

Armouring is best suited for fixed installations and particularly direct burial. Bothtypes of protection are sheathed with either an exterior grade PVC or polyethylene.

Low Smoke Halogen Free sheaths for special installations are also available.

Standard cables can be braided or armoured for quantities as low as 100m.

Armouring

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

153SPECIAL MANUFACTURE

1 2 3 4

CURRENT-CARRYING CAPACITY (amperes):Ambient temperature: 30ºC

Conductor operating temperature: 60ºC

Conductorcross-

sectionalarea

Single-phase a.c. or d.c.

(A) (A) (A)4 30 26 -6 39 34 -10 51 47 -16 73 63 -

25 97 83 -35 - 102 14050 - 124 17570 - 158 21695 - 192 258

1 three-core, four-core or five-core cable

2 single-core cable1 two-core cable,with or without

protectiveconductor

Three-phase a.c.

Single-phase a.c. or d.c.

Notes:1. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be

wound on a drum on load the ratings should be reduced in accordance with Note 2 below and for cables which may be covered, Note 3 below.

2. Flexible cables wound on reeling drums

The current ratings of cables used on reeling drums are to be reduced by the following factors:

a) Radial type drum b) Ventilated cylindrical type drumventilated: 85% 1 layer of cable: 85%unventilated: 75% 2 layers of cable: 65%

3 layers of cable: 45%4 layers of cable: 35%

A radial type drum is one where spiral layers of cable are accommodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated.

A ventilated cylindrical cable drum is one where layers of cable are accommodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures.

3.Where cable may be covered over or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide.

Refer to Notes 1, 2 & 3 below

(mm2)

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

154 TECHNICAL Table 4F1A

Table 4F1A 60oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured

1 2 3 4 5 6

VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 60ºC

Conductorcross-

sectionalarea

Two-corecable, d.c.

Two-core cable,single-phase a.c.

2 single-core cables,touching

Single-phase a.c.*d.c.

1 three-core, four-core orfive-core cable,three-phase a.c.

Notes:* A larger voltage drop will result if the cables are spaced.

(mm2) (mV/A/m) (mV/A/m) (mV/A/m) (mV/A/m)

4 12 12 10 - -

6 7.8 7.8 6.7 - -

10 4.6 4.6 4.0 - -

16 2.9 2.9 2.5 - -

r x z r x z r x z

25 1.80 1.80 0.175 1.85 1.55 0.150 1.55 - - - -

35 - - - - 1.10 0.150 1.15 1.31 1.31 0.21 1.32

50 - - - - 0.83 0.145 0.84 0.91 0.91 0.21 0.93

70 - - - - 0.57 0.140 0.58 0.64 0.64 0.20 0.67

95 - - - - 0.42 0.135 0.44 0.49 0.49 0.195 0.53

(mV/A/m)

These extracts from the 17th Edition Wiring Regulations

are reproduced by kind permission of the Institution of

Engineering and Technology and British Standards

Institution. Copyright IET / BSI 2008.

The extracts are for guidance only, please refer to

BS 7671: 2008 Requirements for Electrical Installations

(IEE Wiring Regulations 17th Edition) for further reference.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

155Table 4F1B TECHNICAL

600C Thermosetting Insulated Flexible CablesTable 4F1B

1 2 3 4 5 6 7 8 9

1 two- 1 three- 1 two- 1 three- 1 two 1 three- 1 two- 1 three-core cable* core cable* core core core cable* core cable* core cable* core cable*

single- or cable* cable* single- or single- orphase 1 four-core single- or phase 1 four-core phase 1 four-core

a.c. or d.c. cable, three- phase 1 four-core a.c.or d.c. cable, a.c. or d.c. cable,phase a.c. a.c. or d.c. cable, three- three- three

phase a.c. phase a.c. phase a.c.

Reference Method A(enclosed in conduit

in thermally insulating wall etc.)

Conductorcross-

sectionalarea

Reference Method B(enclosed in conduit

on a wallor in trunking etc.)

Reference Method E(free air or on a

perforated cable tray etc, horizontal or vertical)

Reference Method C(clipped direct)

* With or without protective conductor.

(mm2) (A) (A) (A) (A) (A) (A) (A) (A)

1 11 10 13 11.5 15 13.5 17 14.51.5 14 13 16.5 15 19.5 17.5 22 18.52.5 18.5 17.5 23 20 27 24 30 254 25 23 30 27 36 32 40 346 32 29 38 34 46 41 51 4310 43 39 52 46 63 57 70 6016 57 52 69 62 85 76 94 80

1 2 3 4

VOLTAGE DROP (per ampere per metre):

Conductorcross-

sectional area

Two-corecable d.c.

Two-core cablesingle-phase a.c.

Three- or four-core cablethree-phase a.c.

Table 4D2B

(mm2) (mV/A/m) (mV/A/m) (mV/A/m)1 44 44 381.5 29 29 252.5 18 18 154 11 11 9.56 7.3 7.3 6.4

10 4.4 4.4 3.816 2.8 2.8 2.4

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

156 TECHNICAL Table 4D2A & 4D2B

Ambient temperature: 30ºCCURRENT-CARRYING CAPACITY (amperes): Conductor operating temperature: 70ºC

Table 4D2A Multicore 70oC Thermoplastic Insulated and Thermoplastic Sheathed Cables, Non-Armoured

Conductor operating temperature: 70ºC

1 2 3 4 5 6 7 8 9

1 two- 1 three- 1 two-core 1 three- 1 two-core 1 three- 1 two-core 1 three-core cable* or four-core cable*, or four-core cable* or four-core cable*, or four-core

single- cable*, single- cable*, single- cable*, single- cable*,phase three- phase three- phase three- phase three-

a.c. or d.c. phase a.c. a.c. or d.c. phase a.c. a.c.or d.c. phase a.c. a.c. or d.c. phase a.c.

Reference Method A(enclosed in conduit

in thermally insulating wall etc.)

Conductorcross-

sectionalarea

Reference Method B(enclosed in conduit

on a wallor in trunking etc.)

Reference Method E(free air or on a

perforated cable tray etc, horizontal or vertical)

Reference Method C(clipped direct)

Notes:1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to

the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2)2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not

exceeding 70ºC, the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables (Table 4D2A) must be used (see also Regulation 523.1) * With or without protective conductor.

(mm2) (A) (A) (A) (A) (A) (A) (A) (A)1 14.5 13 17 15 19 17 21 18

1.5 18.5 16.5 22 19.5 24 22 26 232.5 25 22 30 26 33 30 36 324 33 30 40 35 45 40 49 426 42 38 51 44 58 52 63 5410 57 51 69 60 80 71 86 7516 76 68 91 80 107 96 115 100

1 2 3 4

VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 90ºC

Conductorcross-

sectionalarea

Two-corecable, d.c.

Two-core cablesingle-phase, a.c.

Three-or four-core cable,three-phase a.c.

Table 4E2B

(mm2) (mV/A/m) (mV/A/m) (mV/A/m)1 46 46 40

1.5 31 31 272.5 19 19 16

4 12 12 106 7.9 7.9 6.8

10 4.7 4.7 4.016 2.9 2.9 2.5

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

157Table 4E2A & 4E2B TECHNICAL

Table 4E2A Multicore 90oC Thermosetting Insulatedand Thermoplastic Sheathed Cables, Non-Armoured

Ambient temperature: 30ºCCURRENT-CARRYING CAPACITY (amperes): Conductor operating temperature: 90ºC

12

34

56

78

910

1112

2 ca

bles

,3

or 4

2 ca

bles

,3

or 4

2 ca

bles

,3

or 4

2 ca

bles

,3

3 ca

bles

,2

cabl

es, s

ingl

e-ph

ase

sing

le-

cabl

es,

sing

le-

cabl

es,

sing

le-

cabl

essi

ngle

-ca

bles

,th

ree-

a.c.

or d

.c. o

r ph

ase

thre

e-ph

ase

thre

e-ph

ase

thre

e-ph

ase

a.c.

thre

e-ph

ase

phas

e3

cabl

esa.

c. o

r d.c

.ph

ase

a.c.

a.c.

or d

.c.

phas

e a.

c.a.

c. o

r d.c

.ph

ase

a. c

.or

d.c

. fla

ta.

c.fla

ta.

c. tr

efoi

lth

ree-

phas

e a.

c. fl

atfla

t and

flat a

ndto

uchi

ngto

uchi

ngor

tref

oil

Refe

renc

e M

etho

d A

(enc

lose

d in

con

duit

in th

erm

ally

insu

latin

g w

all e

tc.)

Cond

ucto

rcr

oss-

sect

iona

lar

ea

Refe

renc

e M

etho

d B

(enc

lose

d in

con

duit

on a

wal

l or i

ntr

unki

ng e

tc.)

Refe

renc

e M

etho

d F

(in fr

ee a

ir on

a p

erfo

rate

d ca

ble

tray

horiz

onta

l or v

ertic

al e

tc.)

Touc

hing

Refe

renc

e M

etho

d G

(in

free

air)

Spac

ed b

y on

e ca

ble

diam

eter

Refe

renc

e M

etho

d C

(clip

ped

dire

ct)

Sin

gle

Co

re 9

0oC

Th

erm

ose

ttin

g I

nsu

late

d C

ab

les,

Un

arm

ou

red

, W

ith

or

Wit

ho

ut

Sh

eath

Ambi

ent t

empe

ratu

re: 3

0ºC

CU

RR

EN

T-C

AR

RY

ING

CA

PAC

ITY

(am

pere

s):

Cond

ucto

r ope

ratin

g te

mpa

ratu

re:9

0ºC

Horiz

onta

l

V

ertic

al

(mm

2 )(A

)(A

)(A

)(A

)(A

)(A

)(A

)(A

)(A

)(A

)(A

)

114

1317

1519

17.5

--

--

-

1.5

1917

2320

2523

--

--

-

2.5

2623

3128

3431

--

--

-

435

3142

3746

41-

--

--

645

4054

4859

54-

--

--

1061

5475

6681

74-

--

--

1681

7310

088

109

99-

--

--

2510

695

133

117

143

130

161

141

135

182

161

3513

111

716

414

417

616

120

017

616

922

620

1

5015

814

119

817

522

820

924

221

620

727

524

6

7020

017

925

322

229

326

831

027

926

835

331

8

9524

121

630

626

935

532

637

734

232

843

038

9

No

tes:

1.W

here

a c

ondu

ctor

oper

ates

at a

tem

pera

ture

exc

eedi

ng70

ºC it

mus

t be

asce

rtai

ned

that

the

equi

pmen

t con

nect

ed to

the

cond

ucto

r is

suita

ble

for t

he c

ondu

ctor

oper

atin

g te

mpe

ratu

re(s

ee R

egul

atio

n 51

2.1.

2)

2.W

here

cab

les

in th

ista

ble

are

conn

ecte

d to

eq

uipm

ent o

r acc

esso

ries

desi

gned

to o

pera

te a

t a

tem

pera

ture

not

exce

edin

g 70

ºC, t

hecu

rren

t rat

ings

giv

en in

the

equi

vale

nt ta

ble

for

70ºC

ther

mop

last

icin

sula

ted

cabl

es (T

able

4D1A

) mus

t be

used

(see

also

Reg

ulat

ion

523.

1)

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

158 TECHNICAL Table 4E1A

Table 4E1A

12

34

56

78

9

2 ca

bles

, sin

gle-

phas

e a.

c.

VO

LTA

GE

DR

OP

(per

am

pere

per

met

re):

Cond

ucto

r ope

ratin

g te

mpe

ratu

re: 9

0ºC

3 or

4 c

able

s, th

ree-

phas

e a.

c.

No

tes:

*

Spac

ings

larg

er th

an o

ne c

able

dia

met

er w

ill re

sult

in a

larg

er v

olta

ge d

rop.

rx

z

1.60

0.27

1.65

1.15

0.26

1.20

0.86

0.26

0.89

0.59

0.25

0.65

0.43

0.25

0.49

rx

zr

xz

rx

zr

xz

rx

zr

xz

251.

851.

850.

311.

901.

850.

190

1.85

1.85

0.28

1.85

1.60

0.27

1.65

1.60

0.16

51.

601.

600.

190

1.60

351.

351.

350.

291.

351.

350.

180

1.35

1.35

0.27

1.35

1.15

0.25

1.15

1.15

0.15

51.

151.

150.

180

1.15

500.

991.

000.

291.

050.

990.

180

1.00

0.99

0.27

1.00

0.87

0.25

0.90

0.86

0.15

50.

870.

860.

180

0.87

700.

680.

700.

280.

750.

680.

175

0.71

0.68

0.26

0.73

0.60

0.24

0.65

0.59

0.15

00.

610.

590.

175

0.62

950.

490.

510.

270.

580.

490.

170

0.52

0.49

0.26

0.56

0.44

0.23

0.50

0.43

0.14

50.

450.

430.

170

0.46

Cabl

es to

uchi

ngCa

bles

spa

ced*

Refe

renc

eRe

fere

nce

Refe

renc

eRe

fere

nce

Met

hods

A &

BM

etho

ds C

, F &

GM

etho

ds A

& B

Met

hods

C, F

& G

(enc

lose

d in

(clip

ped

dire

ct, o

n tr

ay o

r in

free

air)

Refe

renc

e(c

lippe

d di

rect

, on

tray

or i

n fre

e ai

r)co

ndui

t or

(enc

lose

d in

trun

king

)co

ndui

t or

trun

king

)Ca

bles

touc

hing

,Tr

efoi

lCa

bles

touc

hing

, Fl

atCa

bles

spa

ced*

,Fl

at

Cond

ucto

r cr

oss-

se

ctio

nal

area

2 ca

bles

d.

c.

(mm

2 )(m

V)(m

V/A/

m)

(mV/

A/m

)(m

V/A/

m)

(mV/

A/m

)(m

V/A/

m)

(mV/

A/m

)(m

V/A/

m)

146

4646

4640

4040

401.

531

3131

3127

2727

272.

519

1919

1916

1616

164

1212

1212

1010

1010

67.

97.

97.

97.

96.

86.

86.

86.

810

4.7

4.7

4.7

4.7

4.0

4.0

4.0

4.0

162.

92.

92.

92.

92.

52.

52.

52.

5

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

159Table 4E1B TECHNICAL

Table 4E1B

Sin

gle

Co

re 9

0oC

PV

C T

herm

ose

ttin

g I

nsu

late

d C

ab

les

1 2 3 4

CURRENT-CARRYING CAPACITY (amperes):

Conductorcross-

sectionalarea

Table 4F2A

(mm2) (A) (A) (A)

4 42 37 -6 55 49 -10 76 66 -16 103 89 -25 136 119 -35 - 146 20050 - 177 25070 - 225 31095 - 273 369

Refer to Notes 1 to 3 on page 154 and Notes 4 to 6 below

Three-phase a.c.(1 three-core, four-core

or five-core cable)

Single-phase a.c. or d.c.,

2 single-core cables, touching

90oC and 180oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured

RATING FACTOR FOR AMBIENT TEMPERATURE:

90ºC thermosetting insulated cables:

Ambient temperature 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC 75ºC 80ºC 85ºC

Rating factor 0.95 0.91 0.86 0.82 0.76 0.70 0.64 0.57 0.50 0.40 0.28

180ºC thermosetting insulated cables:

Ambient temperature 35ºC to 90ºC 95ºC 100ºC 105ºC 110ºC 115ºC 120ºC 125ºC 130ºC 135ºC 140ºC 145ºC

Rating factor 1.0 0.96 0.91 0.86 0.81 0.76 0.70 0.64 0.57 0.50 0.40 0.28

Notes:4. For 180ºC cables the rating factors for ambient temperature allow a conductor operating temperature up to 150ºC. Consult the cable

manufacturer for further information.

5. The temperature limits given in the 17th Edition Wiring Regulations hould be taken into account when it is intended to operate these cables at maximium permissible temperature.

6. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temeperature (see Regulation 512.1.2)

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

160 TECHNICAL Table 4F2A

Ambient temperature: 30ºCConductor operating temperature: 90ºC

d.c. or single-phase a.c.

(1 two-core cable, with or without

protective conductor)

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

161Table 4F2B TECHNICAL

1 2 3 4 5

VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 90ºC

Conductorcross-

sectionalarea

1 two-coreor 2 single-core cables

d.c.

Two-core cable,single-phase a.c.

2 single-core cables,touching

Single-phase a.c.*

1 three-core, four-core orfive-core cable,three-phase a.c.

Notes:

1. The voltage drop figures given above are based on a conductor operating temperature of 90ºC and aretherefore not accurate when the operating temperature is in excess of 90ºC. In the case of the 180ºCcables with a conductor temperature of 150ºC the above resistive values should be increased by a factorof 1.2.

2 * A larger voltage drop will result if the cables are spaced.

Table 4F2B

(mm2) (mV/A/m) (mV/A/m) (mV/A/m) (mV/A/m)4 13.2 13.2 11.1 -6 8.5 8.5 7.4 -

10 5.1 5.1 4.4 -16 3.2 3.2 2.7 -

r x z r x z r x z25 2.03 2.03 0.175 2.04 1.73 0.15 1.73 - - -35 1.42 - - - 1.22 0.15 1.23 1.44 0.21 1.46

50 1.00 - - - 0.91 0.145 0.93 1.00 0.21 1.0270 0.71 - - - 0.62 0.14 0.64 0.71 0.20 0.7395 0.54 - - - 0.47 0.135 0.49 0.54 0.195 0.57

90oC and 180oC Thermosetting Insulated Flexible Cables

1 2 3 4

CURRENT-CARRYING CAPACITY (amperes): and MASS SUPPORTABLE (kg):

Conductorcross-sectional

area

Current-carrying capacity

Single-phase a.c. Three-phase a.c.

Maximum mass supportable by twin flexible cord (seeRegulations 522.7.2 and

559.6.1.5)

Where cable is on a reel see the notes to the Table in 4F1A

Table 4F3A

(mm2) (A) (A) (kg)

0.5 3 3 20.75 6 6 3

1 10 10 51.25 13 - 51.5 16 16 52.5 25 20 5 4 32 25 5

RATING FACTOR FOR AMBIENT TEMPERATURE

60ºC Thermoplastic or Thermosetting Insulated Cords:Ambient temperature 35ºC 40ºC 45ºC 50ºC 55ºCCorrection factor 0.91 0.82 0.71 0.58 0.41

90ºC Thermoplastic or Thermosetting Insulated Cords: Ambient temperature 35ºC to 50ºC 55ºC 60ºC 65ºC 70ºCCorrection factor 1.0 0.96 0.83 0.67 0.47

180ºC Thermosetting Insulated Cords:Ambient temperature 35ºC to 120ºC 125ºC 130ºC 135ºC 140ºC 145ºCCorrection factor 1.0 0.96 0.85 0.74 0.60 0.42

Glass Fibre Cords:Ambient temperature 35ºC to 150ºC 155ºC 160ºC 165ºC 170ºC 175ºCCorrection factor 1.0 0.92 0.82 0.71 0.57 0.40

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

162 TECHNICAL Table 4F3A

Flexible Cords, Non-Armoured

1 2 3

VOLTAGE DROP (per ampere per metre):

Conductorcross-sectional area

d.c. or single-phase a.c.

Three-phase a.c.

Notes:*The tabulated values above are for 60ºC thermoplastic or thermosetting insulated flexible cords and

for other types of flexible cords they are to be multiplied by the following factors:

For 90ºC Thermoplastic or Thermosetting Insulated 1.09

180ºC Thermosetting Insulated 1.31

185ºC Glass Fibre 1.43

Conductor operating temperature: 60ºC*

Table 4F3B

(mm2) (mV/A/m) (mV/A/m)0.5 93 800.75 62 54

1 46 401.25 37 -1.5 32 272.5 19 164 12 10

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

163Table 4F3B TECHNICAL

Flexible Cords Current Carrying Capacity / Voltage Drop

American Wire Gauge to Metric Conversion - Listed below are some of themost popular strandings, however, many other combinations exist. Resistance figures areapproximate and are given for guidance only.

AWG Cross Section Stranding Resistance AWG Cross Section Stranding Resistancemm2 Ohm/km mm2 Ohm/km

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

164 TECHNICAL AWG/Metric Conversion

38 0.008 1 x 0.10 2125

38 0.009 7 x 0.04 1930

36 0.013 1 x 0.12 1360

36 0.014 7 x 0.05 1217

34 0.020 1 x 0.16 856

34 0.022 7 x 0.06 777

32 0.032 1 x 0.20 538

32 0.034 7 x 0.08 538

32 0.035 19 x 0.05 446

30 0.051 1 x 0.25 338

30 0.057 7 x 0.10 338

30 0.059 19 x 0.06 286

28 0.080 1 x 0.32 213

28 0.089 7 x 0.12 213

28 0.090 19 x 0.08 186

26 0.128 1 x 0.40 134

26 0.141 7 x 0.16 122

26 0.155 19 x 0.10 113

24 0.205 1 x 0.51 84

24 0.227 7 x 0.20 76

24 0.241 19 x 0.12 69

22 0.324 1 x 0.64 53

22 0.355 7 x 0.25 48

22 0.382 19 x 0.16 45

20 0.519 1 x 0.81 33

20 0.563 7 x 0.32 30.4

20 0.616 19 x 0.20 28.3

18 0.785 16 x 0.25 21.2

18 0.823 1 x 1.02 20.9

18 0.90 7 x 0.40 19.2

18 0.96 19 x 0.25 17.9

16 1.30 1 x 1.29 13.2

16 1.23 19 x 0.28 14.0

14 2.08 1 x 1.62 8.28

14 1.94 19 x 0.36 8.86

12 3.31 1 x 2.05 5.20

12 3.08 19 x 0.45 5.58

10 5.26 1 x 2.58 3.28

10 5.26 19 x 0.6 3.28

8 8.38 1 x 3.26 2.06

8 8.35 19 x 0.75 2.06

6 13.29 1 x 4.11 1.59

6 13.29 19 x 0.96 1.59

4 21.15 1 x 5.18 0.815

4 21.14 19 x 1.19 0.815

2 33.63 1 x 6.54 0.513

2 33.61 19 x 1.50 0.513

1 42.41 1 x 7.34 0.424

1 42.38 19 x 1.68 0.424

1/0 53.4 19 x 1.89 0.253

2/0 67.4 19 x 2.17 0.291

4/0 107 19 x 2.68 0.182

250 MCM 127 37 x 2.09 0.139

300 MCM 152 37 x 2.29 0.119

350 MCM 177 37 x 2.47 0.102

400 MCM 202 37 x 2.64 0.091

500 MCM 253 37 x 2.95 0.072

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

165Stranding Chart TECHNICAL

Cross Nearest Stranding Stranding Resistance Stranding Stranding Resistance ApproxSection AWG Class 1 Class 2 Ohm/km Class 5 Class 6 Ohm/km Weight

mm2 Size* Classes 1 & 2 Classes 5 & 6 kg/km

IEC 60228/BS 6360 Conductors for insulated cables

0.14 26 - - - - 18 x 0.10 138 1.35

0.25 24 - - - 14 x 0.16 32 x 0.10 79 2.4

0.34 22 - - - 19 x 0.16 42 x 0.10 57 3.3

0.50 20 1 x 0.80 7 x 0.30 36.0 16 x 0.21 28 x 0.16 38 4.8

0.75 18 1 x 0.97 7 x 0.37 24.5 24 x 0.21 42 x 0.16 26 7.2

1.0 18 1 x 1.13 7 x 0.43 18.1 32 x 0.21 56 x 0.16 19.5 9.6

1.5 16 1 x 1.38 7 x 0.53 12.1 30 x 0.26 84 x 0.16 13.3 14.4

2.5 14 1 x 1.78 7 x 0.67 7.41 50 x 0.26 140 x 0.16 7.98 24

4.0 12 1 x 2.26 7 x 0.85 4.61 56 x 0.31 224 x 0.16 4.95 38

6.0 10 1 x 2.76 7 x 1.04 3.08 84 x 0.31 192 x 0.21 3.3 58

10 8 1 x 3.57 7 x 1.35 1.83 80 x 0.41 320 x 0.21 1.91 96

16 6 1 x 4.5 17 x 1.70 1.15 128 x 0.41 512 x 0.21 1.21 154

25 4 – 7 x 2.14 0.72 200 x 0.41 800 x 0.21 0.78 240

35 2 – 7 x 2.52 0.52 280 x 0.41 1120 x 0.21 0.55 336

50 1/0 – 19 x 1.78 0.39 400 x 0.41 705 x 0.31 0.39 480

70 2/0 – 19 x 2.14 0.27 356 x 0.51 990 x 0.31 0.27 672

95 3/0 – 19 x 2.52 0.19 485 x 0.51 1340 x 0.31 0.21 912

120 250MCM – 37 x 2.03 0.15 614 x 0.51 1690 x 0.31 0.16 1152

150 300MCM – 37 x 2.25 0.12 765 x 0.51 2123 x 0.31 0.13 1440

185 400MCM – 37 x 2.52 0.1 944 x 0.51 1470 x 0.41 0.11 1776

240 500MCM – 61 x 2.25 0.07 1225 x 0.51 1905 x 0.41 0.08 2304

300 600MCM – 61 x 2.52 0.06 1530 x 0.51 2385 x 0.41 0.064 2880

400 750MCM – 61 x 2.85 0.05 2035 x 0.51 – 0.068 3840

500 1000MCM – 61 x 3.20 0.04 1768 x 0.60 – 0.0384 4800

The number of strands according to IEC 60228/BS 6360 shown in classes 1 & 2 is obligatory. Stranding shown in classes 5 & 6gives the maximum strand diameters and may have less strands provided the conductor does not exceed the resistance figuresshown. In either case the standard gives the maximum resistance in ohms/km that is permissable for non-tinned conductors.

* AWG sizes are approximate and for information only. Please contact us for exact sizing.

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

166 TECHNICAL Colour Codes - American Style

Colour Chart 1: Conductor/Colour5 Brown6 Blue7 Orange8 Yellow

9 Purple10 Grey11 Pink

Colour Chart 2: Conductor/Colour1 Black2 White3 Red4 Green5 Orange6 Blue7 White/Black8 Red/Black9 Green/Black10 Orange/Black11 Blue/Black12 Black/White13 Red/White14 Green/White15 Blue/White16 Black/Red17 White/Red

35 White/Red/Orange36 Orange/White/Blue37 White/Red/Blue38 Black/White/Green39 White/Black/Green40 Red/White/Green41 Green/White/Blue42 Orange/Red/Green43 Blue/Red/Green44 Black/White/Blue45 White/Black/Blue46 Red/White/Blue47 Green/Orange/Red48 Orange/Red/Blue49 Blue/Orange/Red50 Black/Orange/Red

Colour Chart 3: Pair/Number Colour Combination

14 Green/White15 Green/Blue16 Green/Yellow17 Green/Brown18 Green/Orange19 White/Blue20 White/Yellow21 White/Brown22 White/Orange23 Blue/Yellow24 Blue/Brown25 Blue/Orange26 Brown/Yellow

27 Brown/Orange28 Orange/Yellow29 Purple/Orange30 Purple/Red31 Purple/White32 Purple/Dark Green33 Purple/Light Blue34 Purple/Yellow35 Purple/Brown36 Purple/Black37 Grey/White

Colour Chart 5: Western Electric Standard & CW1308 Telephone Cable Colour Chart

1 White/Blue Blue/White2 White/Orange Orange/White3 White/Green Green/White4 White/Brown Brown/White5 White/Grey Grey/White6 Red/Blue Blue/Red7 Red/Orange Orange/Red8 Red/Green Green/Red9 Red/Brown Brown/Red10 Red/Grey Grey/Red11 Black/Blue Blue/Black12 Black/Orange Orange/Black13 Black/Green Green/Black14 Black/Brown Brown/Black15 Black/Grey Grey/Black

16 Yellow/Blue Blue/Yellow17 Yellow/Orange Orange/Yellow18 Yellow/Green Green/Yellow19 Yellow/Brown Brown/Yellow20 Yellow/Grey Grey/Yellow21 Purple/Blue Blue/Purple22 Purple/Orange Orange/Purple23 Purple/Green Green/Purple24 Purple/Brown Brown/Purple25 Purple/Grey Grey/Purple26 Pink/Blue Blue/Pink27 Pink/Orange Orange/Pink28 Pink/Green Green/Pink29 Pink/Brown Brown/Pink30 Pink/Grey Grey/Pink

1 Black2 White3 Red4 Green

Pair number/colour combination. The second colour denotes the band or stripe, however due to environmental issues the cores may be solid colours instead of bi-colours.

18 Orange/Red19 Blue/Red20 Red/Green21 Orange/Green22 Black/White/Red23 White/Black/Red24 Red/Black/White25 Green/Black/White26 Orange/Black/White27 Blue/Black/White28 Black/Red/Green29 White/Red/Green30 Red/Black/Green31 Green/Black/Orange32 Orange/Black/Green33 Blue/White Orange34 Black/White/Orange

1 Black/Red2 Black/White3 Black/Green4 Black/Blue5 Black/Yellow6 Black/Brown7 Black/Orange8 Red/White9 Red/Green10 Red/Blue11 Red/Yellow12 Red/Brown13 Red/Orange

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

167Colour Codes - European / UK TECHNICAL

* Note: The colour code of 25 core cables has corecolours 23 & 24 replaced with colours 26 & 28.For colour codes above 36 cores please ask for details.

6 White7 Red8 Black9 Yellow10 Violet

1 Red2 Blue3 Green4 Yellow5 White6 Black7 Brown8 Violet9 Orange10 Pink11 Turquoise12 Grey13 Red/Blue14 Green/Red15 Yellow/Red16 White/Red17 Red/Black18 Red/Brown

19 Yellow/Blue20 White/Blue21 Blue/Black22 Orange/Blue23 Green/Blue*24 Grey/Blue*25 Yellow/Green26 White/Green*27 Green/Black28 Orange/Green*29 Grey/Green30 Yellow/Brown31 White/Brown32 Brown/Black33 Grey/Brown34 Yellow/Violet35 Violet/Black36 White/Violet

Colours of tape lappings

On cables with over 25 pairs the first 20 pairs will be repeated with coloured separators or binder tapes to indicate each bundle.

Other colour codes for external telephone cables also exist.

CW1600 Colour Codes

Pairs Colour of Insulation

A-Wire B-Wire

1 White/Blue Blue2 White/Orange Orange3 White/Green Green4 White/Brown Brown5 White/Grey Grey6 Red/Blue Blue7 Red/Orange Orange8 Red/Green Green9 Red/Brown Brown

Pairs Colour of Insulation

A-Wire B-Wire

17 Yellow/Orange Orange18 Yellow/Green Green19 Yellow/Brown Brown20 Yellow/Grey Grey21 Violet/Blue Blue22 Violet/Orange Orange23 Violet/Green Green24 Violet/Brown Brown25 Violet/Grey Grey

Pairs Colour of Insulation

A-Wire B-Wire

9 Red/Brown Brown10 Red/Grey Grey11 Black/Blue Blue12 Black/ Orange Orange13 Black/Green Green14 Black/Brown Brown15 Black/Grey Grey16 Yellow/Blue Blue17 Yellow/Orange Orange

CW1128 & CW1128/1198 Colour Coding Def Style Miniature Cables

Pair A-Wire B-Wire

1 White Blue2 White Orange3 White Green4 White Brown5 White Grey6 Red Blue7 Red Orange8 Red Green9 Red Brown10 Red Grey

1 Blue 2 Orange3 Green 4 Brown5 Grey

Two CoreBlueBrown

Three CoreGreen/Yellow Blue Brown

Cables without earth core:BrownBlackGrey

Four CoreGreen/Yellow BrownBlackGrey

or Green /Yellow Blue Brown Black

Cables without earth core:Blue Brown Black Grey

Five CoreGreen/Yellow Blue Brown Black Grey

Cables without earth core:BlueBrownBlackGreyBlack

The new colour code for mains cables is obligatory from April 2006 and applies to flexible and fixed cables connected to the mains. It does not apply to control or signal.

HD 308 S2 BS 7671 Amendment 2: 2004 Colour Code New European Harmonised Standard For Mains Cables

DIN 47100 European Colour Codes

See page 80

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

168 TECHNICAL Colour Codes - BS 5308

Pair No. A - Wire B - Wire

1 Black Blue2 Black Green3 Blue Green4 Black Brown5 Blue Brown6 Green Brown7 Black White8 Blue White9 Green White10 Brown White11 Black Red12 Blue Red13 Green Red14 Brown Red15 White Red16 Black Orange17 Blue Orange18 Green Orange19 Brown Orange20 White Orange21 Red Orange22 Black Yellow23 Blue Yellow24 Green Yellow25 Brown Yellow26 White Yellow27 Red Yellow28 Orange Yellow29 Black Grey30 Blue Grey31 Green Grey32 Brown Grey33 White Grey34 Red Grey35 Orange Grey36 Yellow Grey37 Black Grey38 Blue Grey39 Green Violet40 Brown Violet41 White Violet42 Red Violet43 Orange Violet44 Yellow Violet45 Grey Violet46 Black Turquoise47 Blue Turquoise48 Green Turquoise49 Brown Turquoise50 White Turquoise

BS 5308 Part 1 Colour CodeUnscreened & Collective Screened

Pair No. A - Wire B - Wire

1 White Blue2 White Orange3 White Green4 White Brown5 White Grey6 Red Blue7 Red Orange8 Red Green9 Red Brown10 Red Grey11 Black Blue12 Black Orange13 Black Green14 Black Brown15 Black Grey16 Yellow Blue17 Yellow Orange18 Yellow Green19 Yellow Brown20 Yellow Grey21 White-Blue Blue22 White-Blue Orange23 White-Blue Green24 White-Blue Brown25 White-Blue Grey26 Red-Blue Blue27 Red-Blue Orange28 Red-Blue Green29 Red-Blue Brown30 Red-Blue Grey31 Blue-Black Blue32 Blue-Black Orange33 Blue-Black Green34 Blue-Black Brown35 Blue-Black Grey36 Yellow-Blue Blue37 Yellow-Blue Orange38 Yellow-Blue Green39 Yellow-Blue Brown40 Yellow-Blue Grey41 White Orange Blue42 White Orange Orange43 White Orange Green44 White Orange Brown45 White Orange Grey46 Orange-Red Blue47 Orange-Red Orange48 Orange-Red Green49 Orange-Red Brown50 Orange-Red Grey

BS 5308 Part 2 Colour CodeUnscreened & Collective Screened

Single Quad (2 pair): Black, Blue, Green, BrownSingle Triple: Blue, Black, GreenIndividually screened pairs can also be identified by a polyester tape over black and blue pairs

Single Quad (2 pair): Blue, Green, Orange, BrownSingle Triple: Blue, White, OrangeIndividually screened pairs can also be identified by a polyester tape over white and blue pairs

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

169LSHF Buyers Guide TECHNICAL

The effects of burning PVC are two-fold. Firstly, the dense smoke producedcan reduce visibility and obscure exit routes. Secondly the harmful hydrogen chloride gas given off isdangerous to people and also has a corrosive effect on electronic equipment potentially causing random,unpredictable failure over a period of time.

Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk. LSHF cables are those which emit negligible amounts of halogens when burnt and have reduced smoke emission properties.Compared with around 28% acid gas emissions of standard PVC, LSHF cables give off less than 0.5% HCl(Gases Evolved During Combustion BS EN 50267, IEC 60754-2). Visibility through smoke emission ismeasured through a 3m³ smoke test (pictured) to IEC 61034.

Confusion still surrounds the terminology used to describe LSHF cables and caution should be exercised when specifying. While LSHF, LS0H, LSZH and 0HLS are the same, it is important to note that LSF is not. LSF (Low Smoke and Fume) often refers to modified PVC compound which can still emit up to 22% HCl and should be regarded as only slightly better than PVC in the event of fire.

Also beware standard PVC cables which are over-sheathed with a LSHF compound. When the jacket burns through the PVC inner sheath or insulation will give off poisonous fumes in just the same way. The FSC range of LSHF cables are LSHF throughout – insulation and sheath.

If you are unsure of what you are buying, ask for written confirmation that the cable is LSHF throughout.

Low Smoke Halogen Free Cabling

When specifying cable for installations in confined areas, computer rooms andother sensitive environments, Low Smoke Halogen Free cables offer significantadvantages over traditional PVC.

Hospitals, airports and train stations are just some examples of areas thatcan be difficult to evacuate in the event of fire. It is now recognised thatsmoke and poisonous fumes can pose a far greater threat to life andproperty than the fire itself.

Standard PVC cables are made up of halogens which, when burnt, give offtoxic gases such as Hydrogen Chloride. When exposed to water – moisturein the air or fire sprinkler systems for example, hydrogen chloride formshighly noxious and corrosive hydrochloric acid.

3m³ smoke test to IEC 61034

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

170 TECHNICAL Certificates & Trade Associations

ISO 9001 Accredited

ISO 9001 is the internationally recognised standard for the qualitymanagement of businesses.

Quality of service and products has been critical to our operation eversince we began.

FS Cables has been a registered company with Quality Certification since 1996.

ISO 14001 Accredited

ISO 14001 provides a framework for reducing our environmentalfootprint through a range of measurable improvement actions.

At FS Cables we believe this accreditation demonstrates ourcommitment to environmental responsibility and sustainability.

We have introduced a number of measures ranging from setting up a recycling programme for all office and commercial waste to carsharing and staff cycling or walking to work.

ISO 14001 Accredited

ISO 14001 provides a framework for reducing our environmentalfootprint through a range of measurable improvement actions.

At FS Cables we believe this accreditation demonstrates ourcommitment to environmental responsibility and sustainability.

We have introduced a number of measures ranging from setting up a recycling programme for all office and commercial waste to car sharing and staff cycling or walking to work.

ISO 14001 Accredited

ISO 14001 provides a framework for reducing our environmentalfootprint through a range of measurable improvement actions.

At FS Cables we believe this accreditation demonstrates ourcommitment to environmental responsibility and sustainability.

We have introduced a number of measures ranging from setting up a recycling programme for all office and commercial waste to carsharing and staff cycling or walking to work.

Investors in People

The Investors in People (IIP) Standard is a business improvement tooldesigned to advance an organisation’s performance through itsemployees.

Awarded in 2005, the IIP Standard places strong emphasis on thepersonal development of our staff through regular review, evaluationand assessment.

By establishing a culture of continuous improvement through trainingwe can ensure that you receive the best possible service.

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

171Certificates & Trade Associations TECHNICAL

Caplink Ltd T/A Flexible & Specialist Cables

Supplier Number: 22288

Date Printed: 31 March 2010 Peter Brookes

Expiry Date: 28 March 2011 Rail Sector Manager

Certificate Number: 4282-22288/70006 Achilles Information Limited

Link-up Registered

Link-up is the UK Rail industry supplier qualification and verificationscheme, designed to assure the quality of products and services boughtby the rail industry.

It is administered on behalf of the rail industry by the Achilles Link-upTeam and is supported and used by most of the major rail companiesthroughout the UK.

BSI Subscribing Member

Subscribing membership to the BSI (British Standards Institute) ensuresFS Cables can stay up to date with the latest standards andcertification programmes.

This enables us to adopt best practices in terms of our operationsensuring the products and services we offer our customers are to thehighest standards.

KNX Manufacturer Member

The KNX standard is an internationally recognised system for homeautomation and building control.

FS Cables is a manufacturer member of both the KNX worldwide andKNX UK Associations.

CEDIA Trade Supplier

The Custom Electronic Design & Installation Association (CEDIA) is anorganisation of experienced companies involved in the design andinstallation of electronic systems for the home.

A number of products for home automation and building control areoffered from stock. Please see page 40-41.

318-TQ 137

AAccess Control 56Alarm Cables 58Antennax™ Feeder Coaxial 38-39Armoured Data & Coaxial Cables 61AUDIO CABLES 49-53AWG / Metric Conversion Chart 164

BBFOU Instrumentation to IEC 60092-376 116-117BFOU Power to IEC 60092-353 114-115Broadcast & Camera Coaxial 32BS 5467 Armoured PVC Power 0.6/1kV 97BS 6724 Armoured LSHF Power 0.6/1kV 98BS 6883 0.6/1kV Shipwiring Power 102-103BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation 104-105BS 6883 658-SW4 Armoured Shipwiring Instrumentation 106-107BS 7917 0.6/1kV Shipwiring Power - Fire Resistant 108-109BS 7917 657M-SW4 Unarmoured ShipwiringInstrumentation - Fire Resistant 110-111BS 7917 658M-SW4 Armoured ShipwiringInstrumentation - Fire Resistant 112-113BUS CABLES 42-48

CCable Standards Cross Reference Chart 172CAN Bus Cables 42Cat-3 Multipair 27Cat-5 Multipair 27Cat-5E UTP & FTP 24-25, 26, 60-61, 62Cat-6A UTP & FTP 25, 26, 60-61Cat-7 25CC-Link 1.10 FieldLink® Cables 43COAXIAL CABLES 28-39COLOUR CODE CHARTS 166-168Composite Coaxial Cables 37, 57CUSTOM MANUFACTURED CABLES 152-153CW1044 Functional Earth 67CW1128 External 68CW1128/1198 Armoured 69CW1308 LSHF Internal 65CW1308 PVC Internal 64CW1411 & CW1417 BT Drop Wire 67CW1600 LSHF Limited Fire Hazard 66CY PVC Bedded Screened Multicore 94

DDATA CABLES 6-27Databus® Foundation Fieldbus Cables 42Def-Standard LSHF Multicore 90Def-Standard PVC Multicore 88-89DeviceNet™ Cables 43Digital Satellite & Cable TV Coaxial 36, 60DMX Cables 52

EEchelon LonWork System Cabling 44Equipment Wire LSHF 95

FFIRE & SECURITY CABLES 54-61Fire Alarm Cable Standard & Enhanced 54, 63Flat PVC Cables 122Flat Speaker Cables 50FT Data & Coaxial 55, 63

GGLANDS 144-146G-Temp 600 136

HH05RR-F 118H07RN-F 119HD Media Composite Cables 40-41HDMI Cables 53HF-120 Unscreened & HF-120-C Screened 126HF-120-C-TP Paired Screened 127HF-265 PUR Encoder 128HF-275 PUR Servo & Feedback Cables 129Hi-Flex HF-100 & HF-100-C PUR 124-125HIGH TEMPERATURE CABLES 130-137HOME AUTOMATION CABLES 40-41

IIBM Cables, Ethernet Cables & Twin-Ax Cables 22Individual & Overall Screened Multipair Data Cable24AWG RS422 Low Capacitance 18Individually Screened Multipair Data Cable 20AWG & 18AWG 19Individually Screened Multipair Data Cable 22AWG Low Capacitance RS422 13, 56, 60-61Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422 14, 60-61Individually Screened Two Pair Data Cable 22AWG 12, 56, 60-61Industrial Ethernet Cables 44Instrumentation, Process Control & PLTC 21Interbus Cables 44

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

172 TECHNICAL Index

JJ-H(St)H LSHF 71

Jointing Kits 147

J-Y(St)Y PVC 70

KKNX Cables 47

LLF-249 91

LiYCY PVC Screened Multicores 78-79

LiYCY-TP PVC Screened Pairs 80-81

LiYY Miniature Signal Cable 74

LONDON UNDERGROUND APPROVED CABLES 62-63

Lutron Grafik Eye Cables 46

MMARINE, OIL & GAS CABLES 102-117

Microphone Cables 49

Modbus 45

Mode Lighting Cables 46

Multicore Speaker Cables 51

Multiple Star Quad Cables 49

NNiltox™ LF-315 LSHF 84

Niltox™ LF-316 LSHF 85

Niltox™ LF-329 LSHF 82-83

Niltox™ LF-318 LSHF 75

Niltox™ LF-319 LSHF 76-77

NSHTöu Drum Reeling 120

NYY Unarmoured Power 100-101

OOutdoor Control Cables 59

Outdoor Data & Coaxial Cables 60

Overall Foil & Braid Screened Cored Data Cable

RS232 & RS423 16

Overall Foil & Braid Screened Data Cables

RS232 & RS422 20

Overall Foil & Braid Screened Paired Data Cable

24AWG RS485 Low Capacitance 15, 56, 60-61

Overall Foil & Braid Screened Paired Data Cable

RS232 & RS422 17

Overall Screened Multicore Data Cable RS232 10

Overall Screened Multipair Data Cable RS232 11, 60

PParallel Speaker Cables 50

Photovoltaic cables 123

Pilz Safety Bus® 45

POWER CABLES 96-101

Profibus 45

P-Temp 260 135

PTFE Single Cores 134

RReelflex PUR-H Drum Reeling 121

RG Coaxial 28-31, 60-61

RiserFlex 0.6/1kV86

RiserShield 0.6/1kV 87

ROBOTICS CABLES 124-129

RUBBER & CRANE CABLES 118-123

SSafe-T-Shield 99

SIGNAL & CONTROL CABLES 72-95

Silicone Multicores 132-133

Silicone Single Cores 130-131

Simmtronic Specs 3 & Lighting Multicores 48

Single Core Enhanced Circuit Integrity 96

Single Pair Screened Data Cable 8, 60

Snake Cables 52

SPIRAL CABLES 142-143

Stranding Chart 165

Structured Wiring External Grade 26

S-Video Cables 53

SY PVC Steel Braided Multicore 92-93

TTECHNICAL TABLES 154-174

Telecom BT, TZC & RA Coaxial 33

TELEPHONE CABLES 64-71

THERMOCOUPLE CABLES 138-141

Three Core Overall Screened Data Cable 9

TOOLS 148-151

Transducer & Load Cell Cables 23

UUnscreened Paired Data Cable 7, 57

URM Coaxial 34-35

YYY PVC 59, 72-73

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

173Index TECHNICAL

www.fscables.com [email protected]

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

174

Conductor Stranding

Standard Description

IEC 60228 Conductor class, stranding and resistance for electric cables.

Flame Retardant Tests

Standard Requirements

IEC 60332-1-2 Vertical flame test on a single wire or cable.

IEC 60332-3-21 Bunched cables 40 minute burn test. Cat A F/R 7.0 litres/metre of combustible material.

IEC 60332-3-22 Bunched cables 40 minute burn test. Cat A 7.0 litres/metre of combustible material.

IEC 60332-3-23 Bunched cables 40 minute burn test. Cat B 3.5 litres/metre of combustible material.

IEC 60332-3-24 Bunched cables 20 minute burn test. Cat C 1.5 litres/metre of combustible material.

IEC 60332-3-25 Bunched cables 20 minute burn test. Cat D 0.5 litres/metre of combustible material.

Fire Resistant Circuit Integrity Tests

IEC 60331-21 Cables up to and including 0.6/1kV. 90 minutes minimum @ 750°C with fire.

IEC 60331-23 Data cables. 90 minutes @ 750°C with fire.

IEC 60331-25 Optical fibre cables. 90 minutes @ 750°C with fire.

IEC 60331-1 & 2 Cables up to and including 0.6/1kV. 120 minutes @ 830°C with fire & mechanical shock.

BS 6387 Cat C Circuit integrity for 3 hours @ 950°C with fire.

BS 6387 Cat W Circuit integrity for 30 minutes @ 650°C. 15 mins with fire, 15 mins with fire & water spray.

BS 6387 Cat Z Circuit integrity for 15 minutes @ 950°C with fire & mechanical shock.

BS 8434-1 Circuit integrity for 30 minutes @ 850°C. Standard 15mins fire, 15 mins with fire & water spray

BS 8434-2 Circuit integrity for 2 hours @ 950°C. 60 mins fire & shock,Enhanced 60 mins fire, shock & water spray.

EN 50200 PH30 Circuit integrity for 30 minutes @ 850°C with fire and mechanical shock.

EN 50200 PH60 Circuit integrity for 60 minutes @ 850°C with fire and mechanical shock.

EN 50200 PH120 Circuit integrity for 120 minutes @ 850°C with fire and mechanical shock.

Halogen Gas Emission Tests

IEC 60754-1 Determination of halogen acid gas generation. Only suitable for cables with emissions of 5% and above. Not suitable for Low Smoke Halogen Free classification.

IEC 60754-2 Determination of the degree of acidity of gases evolved during combustion by measuring pH levels and conductivity. Suitable for Low Smoke Halogen Free classification.

Smoke Generation Tests

IEC 61034-1 Test apparatus for measuring the smoke density of cables.

IEC 61034-2 Test proceedure and requirements. Minimum of 60% light transmission.

Alternative Standard References

EN 60228 BS 6360 VDE 0295

EN 60332-1-2 IEC 60332-1 BS 4066-1EN 50265-2-1 VDE 0482-265-2-1

EN 60332-3-21 Cat A F/R EN 50266-2-1 Cat A F/R

EN 60332-3-22 Cat A IEC 60332-3A BS 4066 pt 3A EN 50266-2-2 Cat A VDE 0482-266-2-2 Cat A

EN 60332-3-23 Cat B IEC 60332-3B BS 4066 pt 3BEN 50266-2-3 Cat B VDE 0482-266-2-3 Cat B

EN 60332-3-24 Cat C IEC 60332-3C BS 4066 pt 3CEN 50266-2-4 Cat C VDE 0482-266-2-4 Cat C

EN 60332-3-25 Cat D EN 50266-2-5 Cat D

IEC 60331 VDE 0472 FE180

IEC 60331-31

BS 5839-1 Clause 26.2d

BS 5839-1 Clause 26.2e

Similar to BS 8434-1 without the water spray test

Similar to BS 8434-2 without the water spray test

EN 50267-2-1 BS 6425-1 VDE 0482-267-2-1

EN 50267-2-2 BS 6425-2 VDE 0482-267-2-2

EN 61034-1 EN 50268-1 BS 7622-1 VDE 0482-1034-1

EN 61034-2 EN 50268-2 BS 7622-2 VDE 0482-1034-2

Alternative Standard References

Alternative Standard References

Alternative Standard References

Alternative Standard References

TECHNICAL Cable Standards Cross Reference Chart

Tel: 01727 840 841 Fax : 01727 840 842

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

General Sales: 01727 840 841Fax: 01727 840 [email protected]

OEM Sales: 01727 849 801Contractor Sales: 01727 849 802Wholesaler Sales: 01727 849 849

FS Cables, Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX

Text the word

followed by your name & addressto 65000

CABLESTexts are charged at your

standard network rate. Your details are only used for catalogue dispatch andorder fulfillment. They are

not shared or disclosed withany third party.

For additional FREE copies of 'the little red book', or if you would like one sent to a colleague, simply contact us using the methods below. Please provide us with the contact and companyname, address, postcode and contact telephone number.

01727 840 841

www.fscables.com/littleredbook

[email protected]

Great effort has been made to ensure the accuracy of the information in this booklet. However products may vary due to manufacturingchanges, technical improvements and commercial factors. In particular, overall diameters and weights are given for guidance only and ifcritical, they should be confirmed at time of order.

All Trade Marks and Trade Names are acknowledged. © Copyright Caplink Ltd 2010. All rights reserved.

No part of this publication may be reproduced or replicated in any form without the express written permission of Caplink Ltd.

FS CablesAlban Point, Alban Park, Hatfield Road,St. Albans, Herts AL4 0JX

flexible and specialist cables

the littlered book

Issue 10

Tel: 01727 840 841Fax: 01727 840 [email protected]

FS Cab

lesthe

little redbook

Issue 10

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

FS

cables FS

cables

FScables

FScables

FS

cables FS

cables

FScables

FSFScablescables

FS Cables Front Cover*:Layout 1 18/11/10 15:33 Page 1