Lit Conix2led
Transcript of Lit Conix2led
-
8/13/2019 Lit Conix2led
1/16
Juno Conix
II LED Trac LightingLED efficiency in a contemporary classic
-
8/13/2019 Lit Conix2led
2/16
Thoroughly up-to-date in every respect, the new Conix II LED fixturespresent a sleek, sculpted aesthetic while raising the bar for trac light
performance and efficiency. Four new fixture types offer outputs ranging
from 1000 lumens to nearly 2,800 lumens, requiring just 19 watts to
40 watts input, respectively. They consume far less energy than equivalent
halogen or ceramic metal halide light sources and deliver superior beam
quality along with a 50,000-hour rated life.
Conix II LED produces crisp, white light with chromaticity within a 3-step
MacAdam Ellipse. Available color temperatures include 2700K, 3000K,
3500K, and 4000K with superb color rendering capabilities. All four fixture
types are compatible with Juno line voltage trac systems and can be
ordered in a choice of stunningly uniform, field-changeable beam spreads.
A timeless classic,now a contemporary hit
The proprietary Juno Conix serieshas always been one of our most
popular trac lights, offering timeless
classical styling with a touch of
contemporary flair. Now, with the
introduction of a complete family of
LED powered fixtures, Conix has come
to represent the state-of-the-art in retail,
commercial, and residential lighting.
Conix
II LED Trac Lighting
2 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
3/16
The elegant Conix II LED features durable, all-metal construction finished
in lustrous white, black, or silver finishes. The fixture footprint is minimized
by attaching the trac head to a vertical, side-mount housing that contains
the LED driver. With 360 rotation and more than 90 vertical aiming, these
fixtures deliver extraordinary functionality. All wiring is fully concealed.
Conix II LED is the work of our LED Product Development Team, which is
comprised of some of the industrys most talented LED specialists. Each
fixture in the family was designed, engineered, and assembled in the USA
and conforms to the very highest standards. A full five-year warranty is furthertestament to the superb quality of these fixtures.
Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
4/16
4 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
5/16
A single LED array provides
exceptional reliability and
performance, as well as chromaticity
within a 3-step MacAdam Ellipse forfixture-to-fixture color consistency
LED driver is contained in a side-
mount, vertical housing to minimize
overall fixture footprint
50,000-hour rated service life
yields many years of maintenance-
free operation
Interchangeable, computer-
designed TIR optics are available
in spot, narrow flood, flood and wide
flood beam spreads
Dimming is optional those with
dimming can be used with a wide
variety of Juno-approved, reverse
phase, electronic low voltage(ELV) dimmers
Integral, bayonet-mount accessory
holder accommodates one accessory
on spot, narrow flood and flood
versions only
Compatible with all Juno line
voltage trac systems and
standard adapter accessories
ENERGY STARQualified;
DesignLightsConsortium Qualified
Conix II LED Trac Lighting
T261L,19 WattsThe miniature T261L Conix II LED requires just 19 watts to produce
up to a brilliant 1021 lumens. It far exceeds the performance of, and
consumes 60% less energy than, an equivalent 50-watt halogen MR16
while lasting more than eight-times longer. Its performance even
surpasses 20W MR16 CMH while providing more than four-times
additional rated life. Though small and compact, this elegant little fixtureproduces highly consistent light in 2700K, 3000K, 3500K, and 4000K
color temperatures with 85 CRI typical; a 3000K high CRI version
which offers 93 CRI typical is also available.
Features
Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
6/16
A single LED array delivers
exceptional performance and
reliability; chromaticity within a 3-step
MacAdam Ellipse provides consistentcolor from fixture-to-fixture
LED driver is contained in a side-
mount, vertical housing that helps
minimize overall fixture footprint
50,000-hour rated service life
yields many years of maintenance-
free operation
Precision-designed, custom reector
features faceted/dimpled surface to
ensure properly mixed colors in spot,
narrow flood, or flood beam spreads;
accessory reflectors are easily
changed in the field
Available in non-dimming or dimming
versions; the latter are dimmable
with a wide variety of Juno-approved,
reverse phase, electronic low voltage(ELV) dimmers
Integral, bayonet-mount accessory
holder accommodates up to two
accessories
Compatible with all Juno line
voltage trac systems and
standard adapter accessories
ENERGY STARQualified;
DesignLightsConsortium Qualified
Conix II LED Trac Lighting
T262L, 24 WattsThe T262L Conix II LED is capable of producing over 1,450 brilliant
lumens while consuming a mere 24 watts. Its light output and
beam distribution exceeds that of equivalent CMH fixtures, but
the Conix II LEDs last up to four-times longer with superior lumen
maintenance, resulting in significant performance advantages and
maintenance cost savings. Compact and contemporary, these highly
efficient fixtures produce accurate, color-consistent light in 2700K,3000K, 3500K, and 4000K color temperatures with 80 CRI minimum;
2700K, 3000K, and 3500K high CRI versions which offer 90 CRI
minimum are also available.
Features
6 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
7/16
A single LED array delivers
exceptional reliability and
performance; chromaticity withina 3-step MacAdam Ellipse provides
outstanding fixture-to-fixture
color consistency
LED driver is contained in a
side-mount, vertical housing
that serves to minimize overall
fixture footprint
50,000-hour rated service life
yields many years of maintenance-
free operation
Precision-designed, custom reector
features faceted/dimpled surface to
ensure properly mixed colors in spot,
narrow flood, or flood beam spreads;
accessory reflectors are easily
changed in the field
Dimming is standard and can be
accomplished with a wide variety
of Juno-approved, reverse phase,electronic low voltage (ELV) dimmers
Integral, bayonet-mount accessory
holder accommodates up to two
accessories
Compatible with all Juno
line voltage trac systems and
wide adapter accessories
ENERGY STARQualified;
DesignLightsConsortium Qualified
Conix II LED Trac Lighting
T263L, 33 WattsThe 33-watt, T263L Conix II LED approximates the light output and
distribution of 39W CMH fixtures, but lasts four-times longer with
significantly better lumen maintenance. It also delivers color consistency
that is far superior to most CMH sources. The T263L produces up to
2,033 brilliant lumens and is available in 2700K, 3000K, 3500K, and
4000K color temperatures with 80 CRI minimum. High CRI versions
which offer 90 CRI minimum are optional at 2700K, 3000K, and 3500K.The 33-watt T263L has a slightly taller driver housing than the less
powerful 24-watt T262L, but since they both feature the same-sized trac
head, the T263L provides a very compact footprint for a 2,000 lumen trac
fixture and they can be mixed together for a seamless visual aesthetic.
Features
Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
8/16
A single LED array provides
exceptional reliability and
performance; chromaticity withina 3-step MacAdam Ellipse
offers excellent fixture-to-fixture
color consistency
LED driver is contained in a
side-mount, vertical housing to
minimize overall fixture footprint
50,000-hour rated service life
yields many years of maintenance-
free operation
Precision-designed, custom reector
features faceted/dimpled surface to
ensure properly mixed colors in the
light beam
Reectors are available in either spot,
narrow flood, or flood beam spreads;
accessory reflectors are easilychanged in the field
Dimming is standard and can be
accomplished with a wide variety
of Juno-approved, reverse phase,
electronic low voltage (ELV) dimmers
Integral, bayonet-mount accessory
holder accommodates up to two
accessories
Compatible with all Juno line
voltage trac systems and wide
adapter accessories
ENERGY STARQualified;
DesignLightsConsortium Qualified
Conix II LED Trac Lighting
T265L, 40 WattsThe T265L Conix II LED requires just 40 watts to produce nearly 2,800
brilliant lumens. That significantly exceeds the performance of 39W
CMH PAR lamps and begins to approach the performance of 70W CMH
when comparing mean performance; plus it offers four-times the rated
service life with instant-on and dimming compatibility not available with
CMH light sources. Though a little larger than the other fixtures in the
line, the T265L shares the same sleek, contemporary shape with therest of the Conix II family. This powerful trac fixture produces accurate,
color-consistent light in 2700K, 3000K, 3500K, and 4000K color
temperatures with 80 CRI minimum; 2700K, 3000K, and 3500K high
CRI versions which offer 90 CRI minimum are also available.
Features
8 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
9/16
Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
10/16
Ultra-efficient LEDs help reduce the amount of carbon emissions we put
into the air, while at the same time reducing our energy bills. And with an
extraordinarily long service life of 50,000 hours, LEDs can operate virtually
maintenance-free for 11 years* in a typical retail setting, dramatically
reducing re-lamping and labor costs. Still greater savings accrue from
reduced HVAC costs resulting from the fact that cool-operating LEDs
project virtually no heat in their light beam.
Furthermore, LEDs contain no mercury, lead, or other toxins that
can be harmful to both you and the environment, so no special (and
expensive) disposal procedures are required. LEDs have no UV
emissions that can damage fade-sensitive materials, and they areinfrared-free and RoHS compliant.
Conix II LED is a green machine that can help you save on energy and
operating expenses as it helps save the environment. And if you are
concerned about complying with todays challenging energy codes and
green initiatives, there is no better solution.
*Based on 12-hours operation per day, seven days a week.
Conix II LED Trac Lighting
Introducing thegreenmachine
One of the best things about choosing
eco-friendly lighting like the Conix II LED
is that in the course of doing the right
thing for the environment, you are also
saving on energy and operating costs.
10 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
11/16
Efficiency and performance by the numbers
Juno 40W3K Conix II
LED Spot 12(T265L)
Juno 33W3K Conix II
LED Spot 11(T263L)
Juno 24W3K Conix II
LED Spot 12(T262L)
Juno 19W3K Conix II
LED Spot 15(T261L)
Performance and CostComparison Over 50,000
Hour Fixture Life
70W PAR38Ceramic
Metal HalideSpot 15
39W PAR30LCeramic
Metal HalideSpot 10
20W PAR30LCeramic
Metal HalideSpot 15
20W MR16Ceramic
Metal HalideSpot 12
39.7 33.2 23.8 19.4 System Watts 75.0 44.0 24.5 24.0
2572 1868 1346 952 Initial Lumens 4100 2400 1200 1000
2379 1728 1245 881 Mean Lumens 2870 1560 780 900
34,750 25,472 17,390 11,130 Center Beam Candlepower 42,000 44,000 14,500 9,000
65 56 57 49 Efficacy (Lumens/Watt) 55 50 49 42
3000K 3000K 3000K 3000K Color Temperature 3000K 3000K 3000K 3000K
50,000 50,000 50,000 50,000 Rated Life (Hours)1 12,500 10,000 12,000 12,000
Operating Cost Summary
$198.50 $166.00 $119.00 $97.00 Total Energy Cost per Fixture2 $375.00 $220.00 $122.50 $120.00
Maintenance Cost per Fixture3 $192.00 $258.00 $172.00 $156.00
$198.50 $166.00 $119.00 $97.00 Total Operating Costs $567.00 $478.00 $294.50 $276.00
$368.50 $312.00 $175.50 $179.00 Total Savings per Fixture
1Ceramic Metal Halide rated life is based on 50% lamp failure; LED rated life is based on 0% failure with 70% lumen maintenance.2Based on electricity costs of $0.10 per kilowatt hour.3Replacement Cost per Lamp + Replacement Labor Cost x Number of Lamp Changes for 50,000 Hour Operation.
Juno Lighting GroupIConix II LED Trac Lighting 1
-
8/13/2019 Lit Conix2led
12/16
AccessoriesCat. No. Descript ion Cat. No. Description
T7459BL Hexcell Louver T7477 Prismatic Spread Lens
T741-6 Color Filters T7478 Linear Spread Lens
T7401-16 Dichroic Filters TIR-1-SP TIR Optic - Spot
T7418 Color Correction Filter1 TIR-1-NFL TIR Optic - Narrow Flood
T7420 Diffusion Lens TIR-1-FL TIR Optic - Flood
T7421 Uniformity Lens TIR-1-WFL TIR Optic - Wide Flood
1T7418 corrects 3000K color to approximately 2700K and
4000K color to approximately 3400K.
For 2700K fixtures, use 0.90 multiplier; for 3000HC fixtures, use 0.85 multiplier;
for 3500K fixtures, use 1.02 multiplier; for 4000K fixtures, use 1.04 multiplier.
Juno T261L Conix II LED SeriesThe miniature T261L Conix II LED fixtures have interchangeable TIR optics which enable uniform spot, narrow flood, floodor wide flood distributions to be achieved. These luminaires have an integral, bayonet-mounted accessory holder thataccommodates one accessory (except wide flood) if desired. It can be specified in either dimming or non-dimming versions.The 19W T261L can deliver up to 1021 lumens, utilizing less than 1/3 of the energy of halogen equivalents and having arated life of 50,000 hours. Available in 2700K, 3000K, 3500K and 4000K color temperatures with standard 85 CRI typical,as well as a 3000K high CRI version, the white-light 19W Conix II LED is compatible with all Juno line voltage trac andstandard adapter accessories.
2The beam spread in degrees and the beam L and W inthe following tables are computed at 50% of centerbeamcandlepower and represent areas of effective illumination.
3In vertical aiming applications, aim point (X) is determinedby dividing distance from the wall (D) by the tangent of the
desired aim angle (A) (0.577 for 30, 1.0 for 45, 1.732 for 60)
FixtureBeamType
BeamSpread
RatedLife
CBCP0 30 30 45 60
MH FC L W FC L W D FC X L W FC X L W D FC X L W
S 15 50000 11130 6 309 1.5 1.5 201 2.1 1.8 3 155 5.2 3.2 1.5 437 3.0 1.6 1.1 6 201 3.5 2.1 1.8
Conix II 19W
LED, 3000K
Spot
8 174 2.0 2.0 113 2.7 2.4 4 87 6.9 4.3 2.0 246 4.0 2.1 1.4 8 113 4.6 2.7 2.4
10 111 2.6 2.6 72 3.4 3.0 5 56 8.7 5.4 2.6 157 5.0 2.6 1.8 10 72 5.8 3.4 3.0
12 77 3.1 3.1 50 4.1 3.6 6 39 10.4 6.5 3.1 109 6.0 3.1 2.2 12 50 6.9 4.1 3.6
14 57 3.6 3.6 37 4.8 4.1 7 28 12.1 7.5 3.6 80 7.0 3.6 2.5 14 37 8.1 4.8 4.1
N 26 50000 4459 4 279 1.9 1.9 181 2.5 2.1 2 139 3.5 4.4 1.9 394 2.0 2.0 1.3 4 181 2.3 2.5 2.1
Conix II 19W
LED, 3000K
Narrow Flood
6 124 2.8 2.8 80 3.8 3.2 3 62 5.2 6.6 2.8 175 3.0 2.9 2.0 6 80 3.5 3.8 3.2
8 70 3.7 3.7 45 5.0 4.3 4 35 6.9 8.8 3.7 99 4.0 3.9 2.6 8 45 4.6 5.0 4.3
10 45 4.6 4.6 29 6.3 5.4 5 22 8.7 11.1 4.6 63 5.0 4.9 3.3 10 29 5.8 6.3 5.4
12 31 5.6 5.6 20 7.6 6.4 6 15 10.4 13.3 5.6 44 6.0 5.9 3.9 12 20 6.9 7.6 6.4
F 40 50000 1992 4 125 2.9 2.9 81 4.1 3.4 1 249 1.7 4.9 1.5 704 1.0 1.7 1.0 3 144 1.7 3.1 2.5
Conix II 19W
LED, 3000K
Flood
5 80 3.7 3.7 52 5.1 4.2 2 62 3.5 9.8 2.9 176 2.0 3.4 2.1 4 81 2.3 4.1 3.4
6 55 4.4 4.4 36 6.1 5.1 3 28 5.2 14.7 4.4 78 3.0 5.1 3.1 5 52 2.9 5.1 4.2
7 41 5.1 5.1 26 7.2 5.9 4 16 6.9 19.6 5.9 44 4.0 6.8 4.1 6 36 3.5 6.1 5.1
8 31 5.9 5.9 20 8.2 6.8 5 10 8.7 24.5 7.3 28 5.0 8.5 5.2 7 26 4.0 7.2 5.9
W 52 50000 1134 2 284 2.0 2.0 184 2.8 2.3 1 142 1.7 14.2 2.0 401 1.0 2.6 1.4 2 184 1.2 2.8 2.3
Conix II 19W
LED, 3000K
Wide Flood
3 126 2.9 2.9 82 4.3 3.4 2 35 3.5 ** 3.9 100 2.0 5.2 2.8 3 82 1.7 4.3 3.4
4 71 3.9 3.9 46 5.7 4.5 3 16 5.2 ** 5.9 45 3.0 7.8 4.2 4 46 2.3 5.7 4.5
5 45 4.9 4.9 29 7.1 5.7 4 9 6.9 ** 7.9 25 4.0 10.4 5.6 5 29 2.9 7.1 5.7
6 32 2.9 5.9 20 8.5 6.8 5 6 8.7 ** 9.8 16 5.0 12.9 6.9 6 20 3.5 8.5 6.8
Series
Color
Temperature
Dimming
Compatibility
Color Rendering
Index
Beam
Spread Finish
T261L
19W Conix IILED
27 2700K3 3000K
35 3500K4 4000K
D DimmableK Not Dimmable
Blank 85 CRI TypicalHC 93 CRI Typical
(3000K only)
S SpotN Narrow FloodF FloodW WideFlood
BL BlackSL SilverWH White
Ordering Information Examples: T261L-27K-S-WH, T261L-3D-HC-N-BL
Vertical Aiming AnglesHorizontal Aiming Angles
Notes and DefinitionsCBCP Center Beam Candlepower
A Aiming angle of fixture/lamp, measured
from 0 vertical
MH Vertical distance from the fixture/lamp to
the horizontal surface
FC Footcandles at beam center (aim point)
L Length of beam2
W Width of beam2
D Distance from fixture/lamp to wall3
X Vertical distance to the center of the
beam measured from ceiling3
Horizontal Aiming Angles
Aiming Angle (A=0) Aiming Angle (A=30)
Vertical Aiming AnglesAiming angles for vertical surfacesinclude: 30, 45 and 60
**Due to steep aiming angle, length of beam extends beyond 25'.
12 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
13/16
For 2700K fixtures, use 0.93 multiplier; for 2700HC fixtures, use 0.78 multiplier; for 3000HC fixtures, use 0.84 multiplier;
for 3500K fixtures, use 1.01 multiplier; for 3500HC fixtures, use 0.89 multiplier; for 4000K fixtures, use 1.02 multiplier.
Juno T262L Conix II LED SeriesThe T262L Conix II LED fixtures use interchangeable, precision, computer-designed reflectors to achieve enable uniformspot, narrow flood or flood beam patterns. These luminaires have an integral, bayonet-mounted accessory holder thataccommodates up to two accessories if desired. It can be specified in either dimming or non-dimming versions. The 24WT262L can deliver up to 1457 lumens, outperforming CMH equivalent fixtures while consuming less energy, and has a ratedlife of 50,000 hours. Available in 2700K, 3000K, 3500K and 4000K color temperatures with standard 80 CRI minimum,as well as high CRI versions, the white-light 24W Conix II LED is compatible with all Juno line voltage trac and standardadapter accessories.
Series
Color
Temperature
Dimming
Compatibility
Color Rendering
Index
Beam
Spread Finish
T262L
24W Conix IILED
27 2700K3 3000K
35 3500K
4 4000K
D DimmableK Not Dimmable
Blank 80 CRI MinimumHC1 90 CRI Minimum
S SpotN Narrow FloodF Flood
BL BlackSL SilverWH White
Ordering Information Examples: T262L-27K-HC-S-WH, T262L-3D-N-BL
AccessoriesCat. No. Description Cat. No. Descript ion
T569BL Cube Cell Louver T5678 Linear Spread Lens
T561-6 Color Filters TR3-CL-SP Reflector - Spot
T5618 Color Correction Filter2 TR3-CL-NFL Reflector - Narrow Flood
T5621 Uniformity Lens TR3-CL-FL Reflector - Flood
T5677 Prismatic Spread Lens
2T5618 corrects 3000K color to approximately 2700K and
4000K color to approximately 3400K.
Horizontal Aiming Angles
Aiming Angle (A=0) Aiming Angle (A=30)
Vertical Aiming AnglesAiming angles for vertical surfacesinclude: 30, 45 and 60
12700K, 3000K and 3500K only
FixtureBeamType
BeamSpread
RatedLife
CBCP0 30 30 45 60
MH FC L W FC L W D FC X L W FC X L W D FC X L W
S 12 50000 17390 12 121 2.6 2.6 78 3.5 3.0 6 60 10.4 5.4 2.6 171 6.0 2.6 1.8 10 113 5.8 2.9 2.
Conix II 24W
LED, 3000K
Spot
14 89 3.0 3.0 58 4.0 3.5 7 44 12.1 6.3 3.0 125 7.0 3.1 2.1 11 93 6.4 3.2 2.
16 68 3.4 3.4 44 4.6 4.0 8 34 13.9 7.1 3.4 96 8.0 3.5 2.4 12 78 6.9 3.5 3.0
18 54 3.9 3.9 35 5.2 4.5 9 27 15.6 8.0 3.9 76 9.0 3.9 2.7 13 67 7.5 3.7 3.
20 43 4.3 4.3 28 5.8 5.0 10 22 17.3 8.9 4.3 61 10.0 4.4 3.0 14 58 8.1 4.0 3.
N 25 50000 6130 7 125 3.1 3.1 81 4.2 3.6 4 48 6.9 8.3 3.5 135 4.0 3.7 2.5 6 111 3.5 3.6 3.
Conix II 24W
LED, 3000K
Narrow Flood
8 96 3.5 3.5 62 4.8 4.1 5 31 8.7 10.4 4.4 87 5.0 4.7 3.1 8 62 4.6 4.8 4.
9 76 4.0 4.0 49 5.4 4.6 6 21 10.4 12.5 5.3 60 6.0 5.6 3.8 10 40 5.8 6.0 5.
10 61 4.4 4.4 40 6.0 5.1 7 16 12.1 14.6 6.2 44 7.0 6.5 4.4 12 28 6.9 7.2 6.
11 51 4.9 4.9 33 6.6 5.6 8 12 13.9 16.6 7.1 34 8.0 7.5 5.0 14 20 8.1 8.4 7.
F 37 50000 3439 5 138 3.4 3.4 89 4.7 3.9 2 107 3.5 8.2 2.7 304 2.0 3.0 1.9 4 140 2.3 3.7 3.
Conix II 24W
LED, 3000K
Flood
6 96 4.1 4.1 62 5.6 4.7 3 48 5.2 12.3 4.1 135 3.0 4.6 2.9 5 89 2.9 4.7 3.9
7 70 4.7 4.7 46 6.5 5.5 4 27 6.9 16.4 5.4 76 4.0 6.1 3.8 6 62 3.5 5.6 4.
8 54 5.4 5.4 35 7.5 6.2 5 17 8.7 20.5 6.8 49 5.0 7.6 4.8 7 46 4.0 6.5 5.
9 42 6.1 6.1 28 8.4 7.0 6 12 10.4 24.6 8.1 34 6.0 9.1 5.7 8 35 4.6 7.5 6.
Vertical Aiming AnglesHorizontal Aiming Angles
3 The beam spread in degrees and the beam L and W in the followingtables are computed at 50% of centerbeam candlepower and representareas of effective illumination.
4 In vertical aiming applications, aim point (X) is determined by dividingdistance from the wall (D) by the tangent of the desired aim angle (A)(0.577 for 30, 1.0 for 45, 1.732 for 60)
Notes and DefinitionsCBCP Center Beam Candlepower
A Aiming angle of fixture/lamp, measured
from 0 vertical
MH Vertical distance from the fixture/lamp to
the horizontal surface
FC Footcandles at beam center (aim point)
L Length of beam3
W Width of beam3
D Distance from fixture/lamp to wall4
X Vertical distance to the center of the
beam measured from ceiling4
5 1/2"
4 5/8"
5 3/4
Juno Lighting GroupIConix II LED Trac Lighting 1
-
8/13/2019 Lit Conix2led
14/16
Accessories
Cat. No. Description Cat. No. Description
T569BL Cube Cell Louver T5678 Linear Spread Lens
T561-6 Color Filters T43 Monopoint
T5618 Color Correction Filter2 TR3-CL-SP Reflector - Spot
T5621 Uniformity Lens TR3-CL-NFL Reflector - Narrow Flood
T5677 Prismatic Spread Lens TR3-CL-FL Reflector - Flood
2 T5618 corrects 3000K color to approximately 2700K and
4000K color to approximately 3400K.
For 2700K fixtures, use 0.93 multiplier; for 2700HC fixtures, use 0.78 multiplier; for 3000HC fixtures, use 0.84 multiplier;
for 3500K fixtures, use 1.01 multiplier; for 3500HC fixtures, use 0.89 multiplier; for 4000K fixtures, use 1.02 multiplier.
Juno T263L Conix II LED SeriesThe T263L Conix II LED fixtures use interchangeable, precision, computer-designed reflectors to achieve enableuniform spot, narrow flood or flood beam patterns. These luminaires have an integral, bayonet-mounted accessoryholder that accommodates up to two accessories if desired. All fixtures are dimming-compatible with a variety ofJuno-approved dimmers. The 33W T263L can deliver up to 2033 lumens, enabling it to outperform 39W CMH fixtures,while also offering a 3x-4x rated life of 50,000 hours. Available in 2700K, 3000K, 3500K and 4000K color temperatureswith standard 80 CRI minimum, as well as high CRI versions, the white-light 33W Conix II LED is compatible with allJuno line voltage trac and wide adapter accessories.
3The beam spread in degrees and the beam L and W inthe following tables are computed at 50% of centerbeamcandlepower and represent areas of effective illumination.
4In vertical aiming applications, aim point (X) is determinedby dividing distance from the wall (D) by the tangent of thedesired aim angle (A) (0.577 for 30, 1.0 for 45, 1.732 for 60)
FixtureBeamType
BeamSpread
RatedLife
CBCP0 30 30 45 60
MH FC L W FC L W D FC X L W FC X L W D FC X L W
S 11 50000 25472 12 177 2.3 2.3 115 3.1 2.7 4 199 6.9 3.2 1.6 563 4.0 1.6 1.1 10 165 5.8 2.6 2.2
Conix II 33W
LED, 3000K
Spot
14 130 2.7 2.7 84 3.6 3.1 6 88 10.4 4.8 2.3 250 6.0 2.4 1.6 12 115 6.9 3.1 2.7
16 100 3.1 3.1 65 4.2 3.6 8 50 13.9 6.4 3.1 141 8.0 3.1 2.2 14 84 8.1 3.6 3.1
18 79 3.5 3.5 51 4.7 4.0 10 32 17.3 8.0 3.9 90 10.0 3.9 2.7 16 65 9.2 4.2 3.6
20 64 3.9 3.9 41 5.2 4.5 12 22 20.8 9.6 4.7 63 12.0 4.7 3.3 18 51 10.4 4.7 4.0
N 22 50000 9257 8 145 3.2 3.2 94 4.3 3.7 4 72 6.9 7.2 3.2 205 4.0 3.3 2.2 6 167 3.5 3.2 2.7
Conix II 33W
LED, 3000K
Narrow Flood
10 93 4.0 4.0 60 5.4 4.6 5 46 8.7 9.0 4.0 131 5.0 4.1 2.8 8 94 4.6 4.3 3.712 64 4.8 4.8 42 6.4 5.5 6 32 10.4 10.8 4.8 91 6.0 4.9 3.4 10 60 5.8 5.4 4.6
14 47 5.5 5.5 31 7.5 6.4 7 24 12.1 12.6 5.5 67 7.0 5.8 3.9 12 42 6.9 6.4 5.5
16 36 6.3 6.3 23 8.6 7.3 8 18 13.9 14.4 6.3 51 8.0 6.6 4.5 14 31 8.1 7.5 6.4
F 37 50000 5193 5 208 3.3 3.3 135 4.6 3.8 2 162 3.5 7.8 2.6 459 2.0 3.0 1.9 5 135 2.9 4.6 3.8
Conix II 33W
LED, 3000K
Flood
6 144 4.0 4.0 94 5.5 4.6 3 72 5.2 11.7 4.0 204 3.0 4.4 2.8 6 94 3.5 5.5 4.6
7 106 4.6 4.6 69 6.4 5.3 4 41 6.9 15.7 5.3 115 4.0 5.9 3.7 7 69 4.0 6.4 5.3
8 81 5.3 5.3 53 7.3 6.1 5 26 8.7 19.6 6.6 73 5.0 7.4 4.7 8 53 4.6 7.3 6.1
9 64 5.9 5.9 42 8.2 6.9 6 18 10.4 23.5 7.9 51 6.0 8.9 5.6 9 42 5.2 8.2 6.9
Series Color Temperature Color Rendering Index Beam Spread Finish
T263L
33W Conix IILED
27K 2700K3K 3000K
35K 3500K4K 4000K
Blank 80 CRI MinimumHC1 90 CRI Minimum
S SpotN Narrow FloodF Flood
BL BlackSL SilverWH White
Ordering Information Examples: T263L-27K-HC-S-WH, T263L-3K-N-BL
Vertical Aiming AnglesHorizontal Aiming Angles
Notes and Definitions
CBCP Center Beam Candlepower
A Aiming angle of fixture/lamp, measured
from 0 vertical
MH Vertical distance from the fixture/lamp to
the horizontal surface
FC Footcandles at beam center (aim point)
L Length of beam3
W Width of beam3
D Distance from fixture/lamp to wall4
X Vertical distance to the center of the
beam measured from ceiling4
Horizontal Aiming Angles
Aiming Angle (A=0) Aiming Angle (A=30)
Vertical Aiming AnglesAiming angles for vertical surfacesinclude: 30, 45 and 60
12700K, 3000K & 3500K only
14 Juno Lighting GroupIConix II LED Trac Lighting
-
8/13/2019 Lit Conix2led
15/16
For 2700K fixtures, use 0.96 multiplier; for 2700HC fixtures, use 0.84 multiplier; for 3000HC fixtures, use 0.88 multiplier;
for 3500K fixtures, use 1.04 multiplier; for 3500HC fixtures, use 0.91 multiplier; for 4000K fixtures, use 1.06 multiplier.
Juno T265L Conix II LED SeriesThe T265L Conix II LED fixtures use interchangeable, precision, computer-designed reflectors to achieve enable uniformspot, narrow flood or flood beam patterns. These luminaires have an integral, bayonet-mounted accessory holder thataccommodates up to two accessories if desired. All fixtures are dimming-compatible with a variety of Juno-approveddimmers. The 40W T263L can deliver up to 2772 lumens, enabling it to approach 70W CMH performance, whileoffering significant energy savings and a 3x-4x rated life of 50,000 hours. Available in 2700K, 3000K, 3500K and 4000Kcolor temperatures with standard 80 CRI minimum, as well as high CRI versions, the white-light 40W Conix II LED iscompatible with all Juno line voltage trac and wide adapter accessories.
Series Color Temperature Color Rendering Index Beam Spread Finish
T265L
40W Conix IILED
27K 2700K3K 3000K
35K 3500K4K 4000K
Blank 80 CRI MinimumHC1 90 CRI Minimum
S SpotN Narrow Flood
F Flood
BL BlackSL Silver
WH White
Ordering Information Examples: T265L-27K-HC-S-WH, T265L-3K-N-BL
Horizontal Aiming Angles
Aiming Angle (A=0) Aiming Angle (A=30)
Vertical Aiming AnglesAiming angles for vertical surfacesinclude: 30, 45 and 60
12700K, 3000K & 3500K only
FixtureBeamType
BeamSpread
RatedLife
CBCP0 30 30 45 60
MH FC L W FC L W D FC X L W FC X L W D FC X L W
S 12 50000 34750 12 241 2.5 2.5 157 3.3 2.9 6 121 10.4 5.1 2.5 341 6.0 2.5 1.8 12 157 6.9 3.3 2.9
Conix II 40W
LED, 3000K
Spot
14 177 2.9 2.9 115 3.9 3.3 8 68 13.9 6.8 3.3 192 8.0 3.3 2.3 14 115 8.1 3.9 3.3
16 136 3.3 3.3 88 4.4 3.8 10 43 17.3 8.5 4.1 123 10.0 4.2 2.9 16 88 9.2 4.4 3.
18 107 3.7 3.7 70 5.0 4.3 12 30 20.8 10.2 5.0 85 12.0 5.0 3.5 18 70 10.4 5.0 4.3
20 87 4.1 4.1 56 5.5 4.8 14 22 24.2 12.0 5.8 63 14.0 5.8 4.1 20 56 11.5 5.5 4.
N 27 50000 10363 8 162 3.8 3.8 105 5.2 4.4 4 81 6.9 9.2 3.8 229 4.0 4.1 2.7 6 187 3.5 3.9 3.3
Conix II 40W
LED, 3000K
Narrow Flood
10 104 4.8 4.8 67 6.5 5.5 5 52 8.7 11.5 4.8 147 5.0 5.1 3.4 8 105 4.6 5.2 4.412 72 5.7 5.7 47 7.8 6.6 6 36 10.4 13.9 5.7 102 6.0 6.1 4.1 10 67 5.8 6.5 5.
14 53 6.7 6.7 34 9.1 7.7 7 26 12.1 16.2 6.7 75 7.0 7.1 4.7 12 47 6.9 7.8 6.
16 40 7.7 7.7 26 10.4 8.8 8 20 13.9 18.5 737 57 8.0 8.1 5.4 14 34 8.1 9.1 7.
F 42 50000 5565 6 155 4.6 4.6 100 6.5 5.3 3 77 5.2 16.5 4.6 219 3.0 5.4 3.3 5 145 2.9 5.4 4.4
Conix II 40W
LED, 3000K
Flood
7 114 5.4 5.4 74 7.5 6.2 4 43 6.9 22.0 6.1 123 4.0 7.2 4.3 6 100 3.5 6.5 5.3
8 87 6.1 6.1 56 8.6 7.1 5 28 8.7 ** 7.7 79 5.0 9.0 5.4 7 74 4.0 7.5 6.
9 69 6.9 6.9 45 9.7 8.0 6 19 10.4 ** 9.2 55 6.0 10.8 6.5 8 56 4.6 8.6 7.
10 56 7.7 7.7 36 10.8 8.9 7 14 12.1 ** 10.7 40 7.0 12.6 7.6 9 45 5.2 9.7 8.0
Vertical Aiming AnglesHorizontal Aiming Angles
3The beam spread in degrees and the beam L and W inthe following tables are computed at 50% of centerbeamcandlepower and represent areas of effective illumination.
4In vertical aiming applications, aim point (X) is determinedby dividing distance from the wall (D) by the tangent of thedesired aim angle (A) (0.577 for 30, 1.0 for 45, 1.732 for 60)
Notes and Definitions
CBCP Center Beam CandlepowerA Aiming angle of fixture/lamp, measured
from 0 vertical
MH Vertical distance from the fixture/lamp tothe horizontal surface
FC Footcandles at beam center (aim point)
L Length of beam3
W Width of beam3
D Distance from fixture/lamp to wall4
X Vertical distance to the center of the
beam measured from ceiling4
Accessories
Cat. No. Description Cat. No. Description
T579BL Cube Cell Louver T5778 Linear Spread Lens
T571-6 Color Filters T43 Monopoint
T5718 Color Correction Filter2 TR1-CL-SP Reflector - Spot
T5721 Uniformity Lens TR1-CL-NFL Reflector - Narrow Flood
T5777 Prismatic Spread Lens TR4-CL-FL Reflector - Flood
2 T5718 corrects 3000K color to approximately 2700K and
4000K color to approximately 3400K.
**Due to steep aiming angle, length of beam extends beyond 25
Juno Lighting GroupIConix II LED Trac Lighting 1
-
8/13/2019 Lit Conix2led
16/16
Please visit junolightinggroup.com/literature for additional
Juno trac lighting brochures
2013 JUNO LIGHTING, LLC. The marks appearing in this catalog are registered trademarks of
Juno Lighting, LLC unless otherwise noted. Products shown in this brochure are covered by U.S.
and international patents and patents pending. Specifications subject to change without notice.
Other marks used herein, including Luxeon, are recognized trademarks of their respective companies.
Printed in the U.S.A. LIT-CONIX2LED 07/2013
LIT-CONIX2LED
Juno Lighting Group
1300 South Wolf Road
Des Plaines, IL 60018
Ph: 847.827.9880
www.junolightinggroup.com
Regional Offices & Warehouses
California
Illinois
Indiana
Pennsylvania
Texas
Ontario, CN
Juno Trac 12
Juno LED Display &Picture Lights
Juno ComprehensiveTrac Lighting Catalog
Juno CylindraLEDTrac Lighting
Juno Flex 12
Juno Trac-Lites
Juno LED DecorativePendants
Juno CylindraLowVoltage LED Trac Lighting
Juno Trac-MasterLEDWall Wash/Flood Fixtures
Juno HD CommercialTrac Lighting System
Juno Current LimitingSolutions
Juno LEDMini-Pendants
Juno MonoLineTrack Systems
Juno ArcLEDTrac Fixtures
Juno Quick Jack LEDDirectional Fixtures