    Calculations

    Liquid Flow (Table #51)

    General Configuration for Liquid Flow Calculation

    Configure the liquid flow calculation and enable it from the General page.

    Calculation: Enable/disable the liquid flow calculation here.

    Descriptor: Enter a text string that identifies the calculation.

    Meter ID: Enter a text string that identifies or names the device associated with thecalculation.

    Flow Type: Select whether a turbine or orifice meter is used.

    API Table Used: Select the API table to be used for this calculation. Options are listed

    below.

    Table 23/24 A Table 23/24 B Table 24 C Old Table 23/24 Table 23/24 E Table 53/54 A Table 53/54 B Table 54 C Old Table 53/54 Propylene (CH 11.3.3) Ethylene (API 2565) Ethylene (NBS 1045)

    Turbine Pickup: If you selected turbine as the flow type, select a single or dual turbinemeter pickup pulse.

    Thermo Fisher Scientific

  • 7/27/2019 LiquidFlow-GeneralConfig

    2/3

    Calculations

    Liquid Flow (Table #51)

    SG Override: To use a live API/SG/density input, enter '0' in this field. Otherwise, enterthe API/SG/density override value.

    Atmospheric Pressure: Enter the current atmospheric pressure in psi measured at theinstallation site.

    K-Factor: Enter the meter's K-Factor.

    Include HYC Fact: If you selected an API A/B table, enter the glass hydrometercorrection factor. Refer to API Chapter 9 or other appropriate density/hydrometerstandards for further explanation.

    Contract Hour: Enter the time of day that the flow computer stores an archive in thedaily historical log and starts a new set of averages and accumulations for a new day.

    ASTM 1250 Selection: Select the ASTM standard being used (ASTM1250-1980 or ASTM1250-2004).

    Meter Pulse Hz: This is a read-only field that displays the current meter pulse.

    Meter Accumulator Pulse: Connect this field to a live value (typically a #20-PhysicalAccumulator entry).

    Current Product Index: This field displays the index of the product that is currently

    running.Reference Temperature: Enter the correction temperature used to calculate SG at 60For density at 15F. The default is to 60.

    BS&W % (Water Cut): Enter the volume percentage of BS&W (basic sediments andwater).

    Meter Active Threshold Hz: This entry determines when a batch starts. If flowmeterinput (Hz) is greater than this value, a batch will start.

    Pulse Deviation Threshold: This field is available if you selected a dual turbine meterpickup pulse. If pulse frequency exceeds this value, the system will begin comparing andtotalizing error counts.

    Density Type: If measuring density, select the type. Options are listed below.

    None 420 mA: If you select 420 mA as the density type, choose the input type

    (SG, API, Density) in the Density Input Select field.

    Density Calc #1#6: Select one of these options if you are using adensitometer and have configured a density calculation.

    Density Input Select: Select the density input type. Options are: SG, API, density.

    Static Pressure: Enter the current line pressure measured on the pipe, or connect thisfield to a live value (typically a #16-Physical Analog Input entry).

    Temperature: Enter the temperature of the fluid, or connect this field to a live value(typically a #16-Physical Analog Input entry).

    Reference Density: If you selected ethylene or propylene as the API table being used,enter density value used to calculate net flow rate.

    Alpha T (E-6): If you selected a table C as the API table being used, enter the thermalexpansion coefficient.

    Error Pulse Hz: If you selected a dual turbine meter pickup pulse, this field displays thecurrent error pulse.

    Error Accumulator Pulse: If you selected a dual turbine meter pickup pulse, connect thisfield to a live value (typically a #20-Physical Accumulator entry).

    Thermo Fisher Scientific

  • 7/27/2019 LiquidFlow-GeneralConfig

    3/3

    Calculations

    Liquid Flow (Table #51)

    Density Temperature Selection: Select whether the meter temperature or densitytemperature is being used.

    Density Pressure Selection: Select whether the meter pressure or density pressure isbeing used.

    Density Temperature: Enter the density temperature.

    Density Pressure: Enter the density pressure.Month Start Day: Enter the day of the month which starts a new contract month.

    Error Count Limit: If any unbalance exists in the two pulse trains and the error countsexceed this threshold, the AutoEXEC will issue an alarm. The error counts will be clearedat the end of a batch.