Lightning rod DELTA RP - ESE

4
Lightning rod DELTA RP ESE

description

Pararrayos con dispositivo de cebado (PDC)

Transcript of Lightning rod DELTA RP - ESE

Page 1: Lightning rod DELTA RP - ESE

Ligh

tnin

g ro

d D

ELTA

RP

ES

E

Page 2: Lightning rod DELTA RP - ESE

ESE Lightning rodswww.aiditec.es

Ligh

tnin

g ro

d D

ELTA

RP

ES

E

Lightning rod DELTA RP ESE

Protection Warranty

Incorporation of new technologies

Triple protection factor

1º WITHSTAND CURRENT*: Applying 10 current pulses with wave lightning 10/350 µs, amplitude of 100 kA and specific energy greater than 2.5 MJ / Ω. According to IEC 61083-1 and IEC 60060-1.2º ADVANCE TIME*:Applying 100 discharge pulses, the procedure set forth in Annex “Evaluation Test of a ESE” of the UNE 21186, NFC 17102 and NP 4426.

The DELTA RP lightning rod has exceeded tests stipulated in the regulations of the AENOR RP 58.01 to early streamer emission.

• SAT - STABILIZATION OF ADVANCE TIME • IAW - INSULATION ASSURANCE WATER

• FBD - FORCED BLOW DEIONIZATION • EOA - EXTENSION OF ARC

TABLE OF PROTECTION RADIOS

Level and effectiveness of protection h ELTA RP-40 ELTA RP-50 ELTA RP-60 ELTA RP-80

Level 4 80% protective efficacy D = 60 mt

2 32 36 40 44

4 62 72 80 85

6 80 90 100 107

8 82 91 101 108

Level 3 90% protective efficacy D = 45 mt

2 25 32 38 39

4 50 60 70 78

6 70 80 90 97

8 71 82 91 98

Level 2 95% protective efficacy D = 30 mt

2 20 25 28 34

4 42 50 60 68

6 55 65 75 87

8 56 66 76 87

Level 1 98% protective efficacy D = 20 mt

2 18 20 26 32

4 34 40 46 63

6 40 50 60 80

8 40 52 61 80

Protection radii in meters according: CTE SU8, UNE 21186, NFC 17102 and NP 4426

h = height of the lightning rod relative to the plane to be protected.

Tests accordingThe RP 58.01

AENORfor ESE

lightning Rod

* The tests have been carried out by the Institute for Energy Technology (ITE), and have been performed on the same air terminals consecutively with the aim of assuring its proper working after withstanding repetitive lightning currents.

PROTECTION RADII CALCULATED WITH ASSURANCE TRIPLE PROTECTION FACTOR, WITH UNCERTAINTY OF 10 μs.

STANDARD COMPLIANCE:The DELTA RP lightning rod complies with all national and international regulations for early streamer emission air terminal.RADIO PROTECTION:Protection radii calculated according to: CTE, UNE 21186, NFC 17102 and NP 4426.

It achieves a maximum deviation of 5% in the advance time performed according to RP 58.01 AENOR, which guarantees the stability of the lightning rod.

In order to provide greater assurance of protection and as a result of the research and R & D developed the lightning rod DELTA RP ESE incorporates the following new technologies.

Maintains permanently isolated the electrodes of the lightning rod wich have to be at a different potential; ensuring lightning rod operation in extreme wet conditions.

Allows quick deionization arc chamber, which ensures that the lightning rod is in perfect condition to capture a new discharge.

Maintains proper tension between the electrodes of the lightning rod that are at different potential, ensuring its perfect running.

Page 3: Lightning rod DELTA RP - ESE

THE INSULATION SYSTEM “ISOLATED RAIN” GUARANTEED TO WORK IN RAIN:

WHEN THE ELECTRIC FIELD VARIES DURING STORM.

DURING THE APPROACH OF THE DOWNWARD LEADER.

SystemIsolation.

“ISOLATEDRAIN “

Operationunder

extreme rain

ESE Lightning rodswww.aiditec.es

In the early streamer emission lightning rod is essential to ensure the insulation between the plates or electrodes that form and are at different potentials.

If adverse weather conditions (heavy rain) this isolation is lost, the triggering device would stop working and therefore can not provide lightning rod protection specified.

The DELTA RP lightning rod ensures operation of triggering device and its effectiveness in protecting thanks to the insulating sleeves “Isolated Rain”, which ensures complete isolation between the electrodes in heavy rain conditions.

The system “Isolated Rain” ensures total isolation in extreme wet conditions, provided by the insulating sleeves that surround the electrodes must permanently maintain the insulation, which prevents rain electrical contact between the metal body of the lightning rod (at potential atmospheric) with the metal shaft (at ground potential).

Lig

htni

ng r

od D

ELTA

RP

ES

E

LIGHTNING CONDUCTOR DELTA RP ESEProtection level

Reference Model Material Dimensions 4 3 2 1 RP

900 001 ELTA RP - 40 Stainless steel Ø 90 x 450 mm 80 70 55 40 1.045,00

900 002 ELTA RP - 50 Stainless steel Ø 90 x 450 mm 90 80 65 50 1.220,00

900 003 ELTA RP - 60 Stainless steel Ø 90 x 450 mm 100 90 75 60 1.400,00

900 004 ELTA RP - 80 Stainless steel Ø 90 x 450 mm 107 97 87 80 1.645,00

Protection Radius

Radius protection for height 6mt of the lightning rod in relation to the plane to be protected.

Installation

The DELTA RP lightning rod installation must be performed as described in the Technical Building Code (CTE) and the UNE 21186, NFC 17102 and NP 4426.

INSULATION TOTAL WARRANTY

Operating in rain

1. Metal housing ending in a point, at atmospheric potential.2. Insulator between housing and shaft.3. Metal shaft at ground potential.4. Insulating sleeve of the metal housing.5. Insulation sleeve of the metal shaft.6. Elongation of the arc chamber.7. Narrowing blowing.

11

4

2

3 7

6

5

4

5

Page 4: Lightning rod DELTA RP - ESE

www.aiditec.es Captadores Pasivos / 4

CA

PTA

DO

RES

PA

SIV

OS

AIDITEC SYSTEMS, S. L. - Parque Tecnológico de Valencia - Avda. Benjamín Franklin, 1246980 Paterna (Valencia) Spain - Tel. +34 96 384 29 57 www.aiditec.es

GENERAL CONDITIONS• Prices are in euros and do not include VAT or any other tax.• Standard packaging is included.• All products are guaranteed for 2 years against any manufacturing defects.

LEGAL NOTICES• This price list is not binding and can be varied without notice.• Due to the policy of constantly improving our products, AIDITEC SYSTEMS, SL reserves the right to change without notice the products in this catalog.• The photos, drawings and technical descriptions of this catalog are not binding. AIDITEC SYSTEMS, SL reserves the right to change at any time and without notice, manufacturing, according to the evolution of standards and techniques used at all times.• AIDITEC SYSTEMS, SL not responsible for printing errors that may appear in this catalog.• You can only copy, electronic reproduction or other permit under AIDITEC SYSTEMS, SL