LIGHT SENSING THERMOSTAT series TL21flairproducts.net/pdfs/Thermostat TL21 spec sheet.pdfswitch an...

2
FLAIR INTERNATIONAL CORPORATION 600 Old Willets Path Hauppauge, New York 11788 TEL: (516) 234-3600 FAX: (516) 234-3610 © 1995 FLAIR INTERNATIONAL CORPORATION FLAIR is a registered trademarks of Flair International Corporation. Bulletin TL21P1 LIGHT SENSING THERMOSTAT series TL21 BENEFITS & SPECIAL FEATURES For central (main) or zoned control of heating and cooling systems. Determines occupancy based on light sensing. Available in single- and multi-stage versions with automatic changeover. 4 minute time delay for compressor protection (may be bypassed). Remote temperature sensor (optional). Return air temperature sensor (optional). Automatic heating/cooling changeover. Electronic temperature limiting and locking. Low and high limit temperature alarms can activate a dry contact to switch an external control. Continuous (on) or intermittent (auto) fan control. System status indicators. Available in single and up to 5 stages of heating/cooling control. Variable set back (setup) control. Light sensing sensitivity adjustment. Simpler and less expensive than clocks, programmers and energy management systems. Operating Voltage: 24 vac (-15%, +10%, 50-60 Hz) Temperature Range: 50° F - 90° F (10° C - 32° C) Light Level Range: Dim: .3 - .5 foot/candles Bright: 35 - 50 foot/candles Temperature Differential: Heating: approximately ±0.8° F (.4° C) Cooling: approximately ±0.8° F (.4° C) Between stages: 2° F (1.1° C) Dead Band: 4° F (2.2° C) Sensor System: Negative Temperature Coefficient (NTC) Standard: internal Optional: remote Compressor Protection: switched 4 minute time delay Switches: Slide: SYSTEM: HEAT/AUTO/COOL Slide: FAN: ON/AUTO Slide: PHOTOCELL: ON/OFF Rotating: Set TEMPerature Indicator LED's: ON (Steady Green) / SETBACK (Flashing Green) ALARM (Flashing Red) / AUX (Steady Red) Security: Electronic temperature limiting and locking Dimensions: 5 43/ 64 x 3 1/ 4 x 1 3 / 16 Inches (144.1 x 82.6 x 30.2 mm) SPECIFICATIONS APPLICATIONS Where automatic setback (heating) or setup (cooling) based on occu- pancy is desired. } Central (main) heating or cooling. Zone heating or cooling. Residential (Single or multi-family, Apartments, Condominiums, Co-ops). Commercial (Stores, Restaurants, Offices). Industrial. Institutional (Hospitals, Hotels, Motels). 3-1/4" (82.6 mm) 5-43/64" (144.1 mm) 1-35/64" (39.3 mm) 1-3/16" (30.2 mm) DIMENSIONS

Transcript of LIGHT SENSING THERMOSTAT series TL21flairproducts.net/pdfs/Thermostat TL21 spec sheet.pdfswitch an...

Page 1: LIGHT SENSING THERMOSTAT series TL21flairproducts.net/pdfs/Thermostat TL21 spec sheet.pdfswitch an external control. Continuous (on) or intermittent (auto) fan control. System status

FLAIR INTERNATIONAL CORPORATION • 600 Old Willets Path • Hauppauge, New York 11788 • TEL: (516) 234-3600 • FAX: (516) 234-3610 © 1995 FLAIR INTERNATIONAL CORPORATION FLAIR is a registered trademarks of Flair International Corporation.

Bulletin TL21P1

LIGHT SENSING

THERMOSTAT series TL21

BENEFITS & SPECIAL FEATURES

For central (main) or zoned control of heating and cooling systems. Determinesoccupancy based on light sensing. Available in single- and multi-stage versionswith automatic changeover.

4 minute time delay for compressor protection (may be bypassed).Remote temperature sensor (optional).Return air temperature sensor (optional).Automatic heating/cooling changeover.Electronic temperature limiting and locking.Low and high limit temperature alarms can activate a dry contact toswitch an external control.Continuous (on) or intermittent (auto) fan control.System status indicators.Available in single and up to 5 stages of heating/cooling control.Variable set back (setup) control.Light sensing sensitivity adjustment.Simpler and less expensive than clocks, programmers and energymanagement systems.

Operating Voltage: 24 vac (-15%, +10%, 50-60 Hz)Temperature Range: 50° F - 90° F (10° C - 32° C)Light Level Range: Dim: .3 - .5 foot/candles

Bright: 35 - 50 foot/candlesTemperature Differential:

Heating: approximately ±0.8° F (.4° C)Cooling: approximately ±0.8° F (.4° C)Between stages: 2° F (1.1° C)

Dead Band: 4° F (2.2° C)Sensor System: Negative Temperature Coefficient (NTC)

Standard: internalOptional: remote

Compressor Protection: switched 4 minute time delaySwitches:

Slide: SYSTEM: HEAT/AUTO/COOLSlide: FAN: ON/AUTOSlide: PHOTOCELL: ON/OFFRotating: Set TEMPerature

Indicator LED's: ON (Steady Green) / SETBACK (Flashing Green)ALARM (Flashing Red) / AUX (Steady Red)

Security: Electronic temperature limiting and lockingDimensions: 543/64 x 31/4 x 13/16 Inches (144.1 x 82.6 x 30.2 mm)

SPECIFICATIONS

APPLICATIONS

Where automaticsetback (heating) orsetup (cooling)based on occu-pancy is desired.

}Central (main) heating or cooling.Zone heating or cooling.Residential (Single or multi-family,Apartments, Condominiums,Co-ops).Commercial (Stores, Restaurants,Offices).Industrial.Institutional (Hospitals, Hotels, Motels).

3-1/4"(82.6 mm)

5-43/64"(144.1 mm)

1-35/64"(39.3 mm)

1-3/16"(30.2 mm)

DIMENSIONS

Page 2: LIGHT SENSING THERMOSTAT series TL21flairproducts.net/pdfs/Thermostat TL21 spec sheet.pdfswitch an external control. Continuous (on) or intermittent (auto) fan control. System status

MODEL NUMBERS AND DESCRIPTIONS FOR VARIOUS APPLICATIONS

Y2

G

W1

W2

Y1

G

W1

W2

Y

A

G

W

Y

X

T

TREMOTESENSOR

AUXILIARYAUXILIARYX

T

TREMOTESENSOR

X

T

T

INPUTS

ALARM/AUX.LED

Y

G

W1

W2

W3

X

T

TNTC TEMP.

SENSOR

REMOTESENSOR

FLAIR INTERNATIONAL CORPORATION600 Old Willets Path • Hauppauge, New York 11788 • Tel: (516) 234-3600 • Fax: (516) 234-3610

OUTPUTSINPUTS

OUTPUTSINPUTS

OUTPUTS

ALARM/AUX.LED

OUTPUTSINPUTS

ALARM/AUX.LED

ALARM/AUX.LED

ALARM/AUX.LED

OUTPUTS

INPUTS

X

T

T

AUXILIARY

REMOTESENSOR

Y2

Y1

W3

W2

W1

G

TL21P2

AUXILIARY

Model Number: TL213220Description: 3 stage heat, 2 stage cool

Light sensingSwitching Current at 24 VAC:

Cooling 1: 1 AmpCooling 2: 1 AmpHeating 1: 1 AmpHeating 2: 1 AmpHeating 3: 1 AmpFan: 1 AmpAlarm: 1 AmpAuxiliary: 1 Amp

Weight: .4 lbs. (880 g)

Switching Current at 24 VAC:Cooling 1: 1 AmpHeating 1: 1 AmpHeating 2: 1 AmpHeating 3: 1 AmpFan: 1 AmpAlarm: 1 AmpAuxiliary: 1 Amp

Weight: .4 lbs. (880 g)

Model Number: TL213120Description: 3 stage heat, 1 stage cool

Light sensing

Model Number: TL212220Description: 2 stage heat, 2 stage cool

Light sensing

Switching Current at 24 VAC:Cooling 1: 1 AmpCooling 2: 1 AmpHeating 1: 1 AmpHeating 2: 1 AmpFan: 1 AmpAlarm: 1 AmpAuxiliary: 1 Amp

Weight: .4 lbs. (880 g)

Model Number: TL212120Description: 2 stage heat, 1 stage cool

Light sensing

Switching Current at 24 VAC:Cooling: 1 AmpHeating 1: 1 AmpHeating 2: 1 AmpFan: 1 AmpAlarm: 1 AmpAuxiliary: 1 Amp

Weight: .4 lbs. (880 g)

Model Number: TL211120Description: 1 stage heat, 1 stage cool

Light sensing

Switching Current at 24 VAC:Cooling: 1 AmpHeating: 1 AmpFan: 1 AmpAlarm: 1 AmpAuxiliary: 1 Amp

Weight: .4 lbs. (880 g)

ON/SETBACKLED

ON/SETBACKLED

ON/SETBACKLED

ON/SETBACKLED

ON/SETBACKLED

LIGHTSENSOR

NTC TEMP.SENSOR

LIGHTSENSOR

NTC TEMP.SENSOR

LIGHTSENSOR

NTC TEMP.SENSOR

LIGHTSENSOR

NTC TEMP.SENSOR

LIGHTSENSOR

Flair pursues a policy of constant improvement. For this reason, all specifications are subject to change without notice.

Indicates this output is protected by a switched4 minute time delay

Remote Temperature Sensor TX101001Return Air Temperature Sensor TX101011Transformers:

40 VA TR14010020 VA TR120100

Relay Transformers:20 VA (2) SPST 120 VAC relay TR44020020 VA (1) SPST 120 VAC relay TR440300

ACCESSORIES

REFERENCESFor More Information On:

Wiring, jumper,potentiometer settingsand applications

Other thermostats

Zone Actuators

Zone Valves

Wiring Panels

Warranty & pricing

Backplates

See:

Instruction sheet

This section

Star Actuator section

Star Valve section

Control Panels section

Pricing & termssection

Accessories sheet

FAN

HEATING

COOLING

A ALARM

FAN

HEATING 1

HEATING 2

COOLING

AA ALARM

FAN

HEATING 1

HEATING 2

COOLING 1

COOLING 2

AA ALARM

AUXILIARY

REMOTESENSOR

FAN

HEATING 1

HEATING 2

HEATING 3

COOLING 1

COOLING 2

AA ALARM

FAN

HEATING 1

HEATING 2

HEATING 3

COOLING

A ALARMA