LIFE BY - Contemporary Fireplace Designs by Lyric Fireplaces
Transcript of LIFE BY - Contemporary Fireplace Designs by Lyric Fireplaces
Enrich any environment with the modern beauty of a Lyric gas fireplace. The Lyric line by Ortal,where modern beauty meets age-old warmth.
The Lyric line includes six fireplace collections: Front Facing, Corner, Three Side, Peninsula,See Through and Stand Alone. Broaden your design horizons with Lyric.
LIFE BY CONTENTSLife by Lyric
The Smart Choice
Lyric Models
Front Facing
Corner
Three Sided
Peninsula
See Through
Stand Alone
Media
Specifications
About and Contact
3
4 - 5
6 - 7
8 - 11
12 - 13
14 - 17
18 - 19
20 - 21
22 - 23
24 - 25
26 - 37
38 - 39
THE SMART CHOICEDiscover Lyric fireplaces, from flawless construction to creative design.From innovative technology to advanced safety features, our advantages give you the creative edge.
Cool Wall Technology Safety Screen BarrierBroaden your design horizons with Cool Wall Technology. Our unique system, lets cool air flow freely between the fireplace and the surrounding walls.Place sensitive materials, valuable décor, and electronics above the fireplace.
Our screen allows you to enjoy the beauty of the fireplace without sacrificing safety. The heat barrier screen is supplied with every Lyric fireplace.
Power VentLiberate yourself from designconstraints with Lyric’s state-of-the-art power vent system. The powerful fan can circulate air through walls and flooring, up to 90 feet away from the fireplace. Install the Lyric fireplace in any location or space you choose.
Captivating FlameOur signature flame provides a spectacular looking fire, adding beauty and warmth to a home.
Slim FitThe Lyric line was designed with especially slim and shallow dimensions. Less depth enables greater flexibility, making it the perfect fit for any space.
Lyric 110 Front
MODELSHigh-quality construction and finish make Lyric fireplaces a smart fit for any project.
LYRIC FRONT
LYRIC CORNER
LYRIC THREE SIDED
LYRIC PENINSULA
LYRIC SEE THROUGH
LYRIC STAND ALONE THREE SIDED
(90H)
FRONT FACINGTimeless design meets modern technology with the Lyric line of front-facing fireplaces.
Marked by age-old elegance, first-class construction, and high-quality finishes, these classic gas fireplaces fit snugly and seamlessly into walls and otherarchitectural elements. Lyric’s front-facing fireplaces are where revolutionary performance meets classic beauty.
Lyric 140 Front
CORNERDraw the eye with an elegantly designed corner fireplace. The clean lines, eye-catching glass media, and alluring flame are what makes Lyric’s corner fireplaces unmistakably modern and undeniably beautiful. Tuck a Corner fireplace into a bedroom nook, nestle between two walls.A Corner fireplace will stand out from its surroundings.
Choose between left-side and right-side models. No matter where you place it, no matter how you style it, the corner fireplace will transform your space and fire your imagination. The Lyric corner fireplace. Modern design. Flawless materials. Flexible options.
LyricCorner110 RS
THREE SIDEDEnjoy beauty and warmth from multiple angles with the Three Sided fireplace.This architectural tour de force transforms a flat scene into a panoramic viewing experience.
Watch the flame from any aspect of a room—from front, left, and right.This elegant model offers greater depth and charm.
Put luxury into perspective with Lyric’s stunning Three Sided fireplace.
LYRICThree Sided110
PENINSULAAppreciate the beauty of a three dimensional view of your flame anywhere in the room, with the Peninsula Lyric fireplace.
Viewable from the front and sides, and another space of the room, this elegant fireplace redefines the concept of modern beauty.
LYRICPeninsula120
SEE THROUGH The Lyric See Through fireplace allows you to push the limits of design. Partition a large room or gathering space with one of our See Through fireplaces.
These beautiful space-dividing units are embedded within a wall or column, providing a view from both sides of the partition.
LYRICSee Through110
STAND ALONEFeaturing simple lines and geometric shapes, Lyric’s Stand Alone fireplaces combine understated charm with modern elegance. Framed beautifully in a square or rectangular body, the fireplace also incorporates a rising vent into the design. Stand Alone fireplaces are also easy to install, requiring no major construction. Turn to these modern gas fireplaces when you want to enhance a space without the hassle of extensive renovation.
LYRICStand Alone40 TS
LYRICStand Alone
75 Ts
MEDIA OPTIONSGaze into the flames dancing on a bed of sparkling glass.Enhance the dramatic effect with Lyric’s internal lighting option.
Polished Obsidian(1 kg per bag) | SKU: MLCB
* Additional media options are available upon request at an additional cost.
Lyric FRONT 90
36-9/16” wide13-3/4” high
36-9/16” wide21-5/8” high
33,100
33,100
19,600
19,600
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
Lyric 90 Front
Lyric 90H Front
Lyric FRONT 90H
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
133 4"
350m
m
369
16"928mm
81 4"
210m
m
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
15
8"41mm
115
16"50mm
23
8"60mm
19
16"40mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
4/9/2018
13
3 4"35
0mm
369
16"928mm
81 4"
210m
m
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
15
8"41mm
115
16"50mm
23
8"60mm
19
16"40mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
4/9/2018
13
3 4"35
0mm
369
16"928mm
81 4"
210m
m
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
15
8"41mm
115
16"50mm
23
8"60mm
19
16"40mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
4/9/2018
13
3 4"35
0mm
369
16"928mm
81 4"
210m
m
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
15
8"41mm
115
16"50mm
23
8"60mm
19
16"40mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
4/9/2018
21
5 8"55
0mm
369
16"928mm
81 4"
210m
m
3"
76m
m
15
3 4"40
0mm
1115
16"
304m
m
115
16"50mm
19
16"40mm
23
8"60mm
18"
3mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
16
1316
"42
7mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
115
16"50mm
4/9/2018
21
5 8"55
0mm
369
16"928mm
81 4"
210m
m
3"
76m
m
15
3 4"40
0mm
1115
16"
304m
m
115
16"50mm
19
16"40mm
23
8"60mm
18"
3mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
16
1316
"42
7mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
115
16"50mm
4/9/2018
21
5 8"55
0mm
369
16"928mm
81 4"
210m
m
3"
76m
m
15
3 4"40
0mm
1115
16"
304m
m
115
16"50mm
19
16"40mm
23
8"60mm
18"
3mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
16
1316
"42
7mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
115
16"50mm
4/9/2018
21
5 8"55
0mm
369
16"928mm
81 4"
210m
m
3"
76m
m
15
3 4"40
0mm
1115
16"
304m
m
115
16"50mm
19
16"40mm
23
8"60mm
18"
3mm
437
8"1114mm
41
1316
"10
62m
m
23
4"70mm
16
1316
"42
7mm
85 16
"21
1mm
2115
16"557mm
778"
200mm 5316"
132mm
115
16"50mm
4/9/2018
Lyric FRONT 140
Lyric 140 Front 56-1/4” wide13-3/4” high
43,700 36,900
43-5/8” wide13-3/4” high
37,100 28,500 5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
Lyric 110 Front
Lyric FRONT 110
MODEL MAX BTU (NG) MAX BTU (LP) VENTGLASS VIEWING AREA
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
435
8"1108mm
81 4"
210m
m
13
3 4"35
0mm
15
8"41mm
238"
60mm
19
16"40mm
115
16"50mm
507
8"1293mm
41
1316
"10
62m
m
85 16
"21
1mm
257
16"647mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
23
4"70mm
4/9/2018
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
435
8"1108mm
81 4"
210m
m
13
3 4"35
0mm
15
8"41mm
238"
60mm
19
16"40mm
115
16"50mm
507
8"1293mm
41
1316
"10
62m
m
85 16
"21
1mm
257
16"647mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
23
4"70mm
4/9/2018
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
435
8"1108mm
81 4"
210m
m
13
3 4"35
0mm
15
8"41mm
238"
60mm
19
16"40mm
115
16"50mm
507
8"1293mm
41
1316
"10
62m
m
85 16
"21
1mm
257
16"647mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
23
4"70mm
4/9/2018
19
1316
"50
4mm
115 8"
296m
m
3"
76m
m
435
8"1108mm
81 4"
210m
m
13
3 4"35
0mm
15
8"41mm
238"
60mm
19
16"40mm
115
16"50mm
507
8"1293mm
41
1316
"10
62m
m
85 16
"21
1mm
257
16"647mm
778"
200mm 5316"
132mm
16
1316
"42
7mm
23
4"70mm
4/9/2018
19
1316
"50
4mm
3"76
mm
13
3 4"35
0mm
81 4"21
0mm
561
4"1428mm
23
8"60mm
158"
41mm
115
16"50mm
13
16"30mm
639
16"1614mm
41
1316
"10
62m
m
85 16
"21
1mm
313
4"807mm
16
1316
"42
7mm
23
4"70mm
5316"
132mm778"
200mm
4/9/2018
19
1316
"50
4mm
3"76
mm
13
3 4"35
0mm
81 4"21
0mm
561
4"1428mm
23
8"60mm
158"
41mm
115
16"50mm
13
16"30mm
639
16"1614mm
41
1316
"10
62m
m
85 16
"21
1mm
313
4"807mm
16
1316
"42
7mm
23
4"70mm
5316"
132mm778"
200mm
4/9/2018
19
1316
"50
4mm
3"76
mm
13
3 4"35
0mm
81 4"21
0mm
561
4"1428mm
23
8"60mm
158"
41mm
115
16"50mm
13
16"30mm
639
16"1614mm
41
1316
"10
62m
m
85 16
"21
1mm
313
4"807mm
16
1316
"42
7mm
23
4"70mm
5316"
132mm778"
200mm
4/9/2018
19
1316
"50
4mm
3"76
mm
13
3 4"35
0mm
81 4"21
0mm
561
4"1428mm
23
8"60mm
158"
41mm
115
16"50mm
13
16"30mm
639
16"1614mm
41
1316
"10
62m
m
85 16
"21
1mm
313
4"807mm
16
1316
"42
7mm
23
4"70mm
5316"
132mm778"
200mm
4/9/2018
Lyric RS 90 Lyric RS 110
Lyric RS 90
Lyric RS 110
37-11/16” wide15-3/4” high
44-13/16” wide15-3/4” high
33,100
37,100
19,600
28,500
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
81 4"
210m
m
275 8"
702m
m
15
3 4"40
0mm
177 8"
455m
m
115
16"50mm
4013
16"1037mm
41
1316
"10
62m
m
19
7 16"
494m
m
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
17
7 8"45
5mm
153 4"
400m
m
115
16"50mm
4113
16"
1062
mm
373
4"958mm
407
8"1038mm
115
16"50mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
14
3 4"37
5mm
207
8"531mm
Corner Rs 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
17
7 8"45
5mm
115
16"50mm
15
3 4"40
0mm
41
1316
"10
62m
m
4413
16"1138mm
4715
16"1217mm
115
16"50mm
247
16"621mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
14
1 8"35
9mm
Corner Rs 110
4/9/2018
81 4"
210m
m
275 8"
702m
m
17
7 8"45
5mm
115
16"50mm
15
3 4"40
0mm
41
1316
"10
62m
m
4413
16"1138mm
4715
16"1217mm
115
16"50mm
247
16"621mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
14
1 8"35
9mm
Corner Rs 110
4/9/2018
81 4"
210m
m
275 8"
702m
m
15
3 4"40
0mm
177 8"
455m
m
115
16"50mm
4013
16"1037mm
41
1316
"10
62m
m
19
7 16"
494m
m
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 90
4/9/2018
Lyric LS 110
Lyric LS 90
Lyric LS 110
37-11/16” wide15-3/4” high
44-13/16” wide15-3/4” high
33,100
37,100
19,600
28,500
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
Lyric LS 90
81 4"
210m
m
275 8"
702m
m
15
3 4"40
0mm
177 8"
455m
m
115
16"50mm
4013
16"1037mm
41
1316
"10
62m
m
19
7 16"
494m
m
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
15
3 4"40
0mm
177 8"
455m
m
115
16"50mm
4013
16"1037mm
41
1316
"10
62m
m
19
7 16"
494m
m
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
115
16"50mm
15
3 4"40
0mm
18"
457m
m
4413
16"1138mm
4715
16"1217mm
115
16"50mm
41
1316
"10
62m
m
14
3 4"37
5mm
231
2"596mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 110
4/9/2018
81 4"
210m
m
275 8"
702m
m
115
16"50mm
15
3 4"40
0mm
18"
457m
m
4413
16"1138mm
4715
16"1217mm
115
16"50mm
41
1316
"10
62m
m
14
3 4"37
5mm
231
2"596mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 110
4/9/2018
81 4"
210m
m
275 8"
702m
m
15
3 4"40
0mm
177 8"
455m
m
115
16"50mm
4013
16"1037mm
41
1316
"10
62m
m
19
7 16"
494m
m
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Corner Ls 90
4/9/2018
Lyric THREE SIDED 90 Lyric THREE SIDED 110
Lyric Three Sided 90
Lyric Three Sided 110
39-13/16” wide15-3/4” high
46-15/16” wide15-3/4” high
33,100
37,100
19,600
28,500
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
81 4"
210m
m
275 8"
702m
m
17
7 8"45
4mm
153 4"
400m
m
115
16"50mm
41
1316
"10
62m
m
397
8"1012mm
3813
16"986mm
14
1116
"37
3mm
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Three sided 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
115
16"50mm
17
7 8"45
5mm
153 4"
400m
m
41
1316
"10
62m
m
4615
16"1192mm
457
8"1166mm
14
3 4"37
5mm
231
2"596mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Three sided 110
4/9/2018
81 4"
210m
m
275 8"
702m
m
17
7 8"45
4mm
153 4"
400m
m
115
16"50mm
41
1316
"10
62m
m
397
8"1012mm
3813
16"986mm
14
1116
"37
3mm
1915
16"506mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Three sided 90
4/9/2018
81 4"
210m
m
275 8"
702m
m
115
16"50mm
17
7 8"45
5mm
153 4"
400m
m
41
1316
"10
62m
m
4615
16"1192mm
457
8"1166mm
14
3 4"37
5mm
231
2"596mm
11
3 16"
284m
m
19
7 16"
494m
m
5316"
132mm77
8"200mm
Three sided 110
4/9/2018
Lyric PENINSULA 120
Lyric Peninsula120
Lyric See Through 110
49-7/16” wide16-11/16” high
43-5/8” wide13-3/4” high
37,100
37,100
28,500
28,500
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
5x8 Co-Axial Direct Vent pipe (5-inch interior, 8-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
Lyric SEE THROUGH 110
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
533
8"1356mm
497
16"1255mm
481
4"1225mm
2916"
65mm
11
16"27mm
29
1316
"75
7mm
17
1 4"43
8mm
63
16"157mm
85 8"
219m
m
283
16"717mm
16
1 4"41
2mm
5316"
132mm
16
1116
"42
4mm
16"
406mm Front side legs
42
7 16"
1078
mm
81 4"
210m
m
778"
200mm
131
4"336mm
Rear Side Legs
Peninsula 120
12/5/2017
533
8"1356mm
497
16"1255mm
481
4"1225mm
2916"
65mm
11
16"27mm
29
1316
"75
7mm
17
1 4"43
8mm
63
16"157mm
85 8"
219m
m
283
16"717mm
16
1 4"41
2mm
5316"
132mm
16
1116
"42
4mm
16"
406mm Front side legs
42
7 16"
1078
mm
81 4"
210m
m
778"
200mm
131
4"336mm
Rear Side Legs
Peninsula 120
12/5/2017
533
8"1356mm
497
16"1255mm
481
4"1225mm
2916"
65mm
11
16"27mm
29
1316
"75
7mm
17
1 4"43
8mm
63
16"157mm
85 8"
219m
m
283
16"717mm
16
1 4"41
2mm
5316"
132mm
16
1116
"42
4mm
16"
406mm Front side legs
42
7 16"
1078
mm
81 4"
210m
m
778"
200mm
131
4"336mm
Rear Side Legs
Peninsula 120
12/5/2017
303
8"772mm
265
8"676mm
279
16"700mm
157
8"404mm
18
1 2"47
0mm
81 2"
216m
m
30
3 16"
768m
m
6716"
164mm
4316"
107mm
14"
356mm
101 8"
257m
m
17
1 4"43
8mm
153
16"386mm
Lyric STAND ALONE 40TS Lyric STAND ALONE 75TS
Lyric Stand Alone 40TS
Lyric Stand Alone 75TS
16-1/4” wide21-3/8” high
23,670 21,073 4x6 Co-Axial Direct Vent pipe (4-inch interior, 6-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
4x6 Co-Axial Direct Vent pipe (4-inch interior, 6-inch exterior)Optional Ortal 35CVS Power Vent System (Inline and Flush) using 3x5
Co-Axial Direct Vent CVS pipe (3-inch interior, 5-inch exterior).
27-9/16” wide18-1/2” high
29,100 22,118
MAX BTU (NG) MAX BTU (LP)GLASS VIEWING AREAMODEL VENT
81 4"
210m
m
33
7 16"
850m
m
21
3 8"54
4mm
14
9 16"
370m
m
4"102mm
578"
150mm
91
2"241mm
83 8"
213m
m
19"
482mm
161
4"412mm
TECHNICAL INFORMATION Front Lyric Series
33
Product SpecificationsLyric direct vent gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP), and not for use with solid fuels. U.S. Certification Codes:ANSI Z21.88/CSA 2.33 - Vented Gas Fireplace Heaters
Canadian Certification Codes:CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace
All Lyric appliances are CSA certified for indoor use only. Lyric appliances are not approved for outdoor installation. Appliances must be installed while maintaining required clearances as outlined in this manual. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliances are not approved for closet installation.
The appliance must be installed according to Lyric requirements in addition to any local codes that may apply, such as:
• USA: ANSI Z223.1/NFPA 54• Canada: CSA B149
All Built-In Lyric fireplaces require a heat release located within 6” of the draft stop.
Series 90-110: Minimum 124 sq. in. of free air spaceSeries 140: Minimum 200 sq. in. of free air space
For installation and framing requirements, please refer to the proper Lyric Installation Manual.
Gas Pressures & Heat Input
DetailsSubject
Natural Gas (NG) or Propane (LPG)Type of Gas
5/8" Direct VentVent
Lyric ScreenHeat Barrier
Leave 20% burner and grill uncovered by mediaGeneral NoteInterior Design Media
180 Ibs.Front 35" (90)
Weight 212 Ibs.Front 43" (110)
253 Ibs.Front 55" (140)
ANSI Z21.88Z/CSA 2.33SafetyStandard
ANSI P.4.1-09Efficiency
Metrik Maxitrol Remote Control (Standard), Wall Switch (Optional)Operation
All models are provided with an AC Adapter, which requires on dedicated minimum 110 Volt, 20 Amp, 60 Hz, 2 gang outlet to be installed in the access panel area adjacent to the gas valve
Electrical Requirements
Series Front Lyric Models Gas
Inlet Pressures Heat Input
Min. Max. Min. Max.
FrontLyric
Series
Natural Gas (NG)
35"(90) NaturalGas (NG) 7.0" WC 11.0" WC 14,461
BTU/hr33,127BTU/hr
43" (110) NaturalGas (NG) 7.0" WC 11.0" WC 22,800
BTU/hr37,100BTU/hr
55"(140) NaturalGas (NG) 7.0" WC 11.0" WC 23,300
BTU/hr43,700BTU/hr
Propane (LPG)
35"(90) Propane(LPG) 11.0" WC 13.0" WC 14,104
BTU/hr19,591BTU/hr
43"(110) Propane(LPG) 11.0" WC 13.0" WC 22,900
BTU/hr28,500BTU/hr
55"(140)Propane
(LPG) 11.0" WC 13.0" WC27,100BTU/hr
36,900BTU/hr
34
TECHNICAL INFORMATION RS/LS Corner Lyric Series
Product SpecificationsLyric direct vent gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP), and not for use with solid fuels. U.S. Certification Codes:ANSI Z21.88/CSA 2.33 - Vented Gas Fireplace Heaters
Canadian Certification Codes:CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace
All Lyric appliances are CSA certified for indoor use only. Lyric appliances are not approved for outdoor installation. Appliances must be installed while maintaining required clearances as outlined in this manual. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliances are not approved for closet installation.
The appliance must be installed according to Lyric requirements in addition to any local codes that may apply, such as:
• USA: ANSI Z223.1/NFPA 54• Canada: CSA B149
All Built-In Lyric fireplaces require a heat release located within 6” of the draft stop.
Series 90-110: Minimum 124 sq. in. of free air spaceSeries 140: Minimum 200 sq. in. of free air space
For installation and framing requirements, please refer to the proper Lyric Installation Manual.
Gas Pressures & Heat Input
DetailsSubject
Natural Gas (NG) or Propane (LPG)Type of Gas
5/8" Direct VentVent
Lyric ScreenHeat Barrier
Leave 20% burner and grill uncovered by mediaGeneral NoteInterior Design Media
207 Ibs.RS/LS 35" (90)Weight
238 IbsRS/LS 43" (110)
ANSI Z21.88Z/CSA 2.33SafetyStandard
ANSI P.4.1-09Efficiency
Metrik Maxitrol Remote Control (Standard), Wall Switch (Optional)Operation
All models are provided with an AC Adapter, which requires on dedicated minimum 110 Volt, 20 Amp, 60 Hz, 2 gang outlet to be installed in the access panel area adjacent to the gas valve
Electrical Requirements
Series RS/LS Lyric Models Gas
Inlet Pressures Heat Input
Min. Max. Min. Max.
RS/L Corner
LyricSeries
Natural Gas (NG)
35"(90) NaturalGas (NG) 7.0" WC 11.0" WC 14,461
BTU/hr33,127BTU/hr
43"(110) NaturalGas (NG) 7.0" WC 11.0" WC 22,800
BTU/hr37,100BTU/hr
Propane (LPG)
35"(90) Propane(LPG) 11.0" WC 13.0" WC 14,104
BTU/hr19,591BTU/hr
43"(110) Propane(LPG) 11.0" WC 13.0" WC 22,900
BTU/hr28,500BTU/hr
TECHNICAL INFORMATION Peninsula Lyric Series
Product SpecificationsLyric direct vent gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP), and not for use with solid fuels. U.S. Certification Codes:ANSI Z21.88/CSA 2.33 - Vented Gas Fireplace Heaters
Canadian Certification Codes:CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace
All Lyric appliances are CSA certified for indoor use only. Lyric appliances are not approved for outdoor installation. Appliances must be installed while maintaining required clearances as outlined in this manual. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliances are not approved for closet installation.
The appliance must be installed according to Lyric requirements in addition to any local codes that may apply, such as:
• USA: ANSI Z223.1/NFPA 54• Canada: CSA B149
All Built-In Lyric fireplaces require a heat release located within 6” of the draft stop.
Series 90-110: Minimum 124 sq. in. of free air spaceSeries 140: Minimum 200 sq. in. of free air space
For installation and framing requirements, please refer to the proper Lyric Installation Manual.
35
Gas Pressures & Heat Input
DetailsSubject
Natural Gas (NG) or Propane (LPG)Type of Gas
5/8" Direct VentVent
Lyric ScreenHeat Barrier
Leave 20% burner and grill uncovered by mediaGeneral NoteInterior Design Media
243 Ibs.Peninsula 47" (120)Weight
ANSI Z21.88Z/CSA 2.33SafetyStandard
ANSI P.4.1-09Efficiency
Metrik Maxitrol Remote Control (Standard), Wall Switch (Optional)Operation
All models are provided with an AC Adapter, which requires on dedicated minimum 110 Volt, 20 Amp, 60 Hz, 2 gang outlet to be installed in the access panel area adjacent to the gas valve
Electrical Requirements
Series Peninsula Lyric Models Gas
Inlet Pressures Heat Input
Min. Max. Min. Max.
PeninsulaLyric
Series
Natural Gas (NG)
47"(120) NaturalGas (NG) 7.0" WC 11.0" WC 22,800
BTU/hr37,100BTU/hr
Propane (LPG)
47"(120) Propane(LPG) 11.0" WC 13.0" WC 22,900
BTU/hr28,500BTU/hr
TECHNICAL INFORMATION Three Sided Lyric SeriesProduct SpecificationsLyric direct vent gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP), and not for use with solid fuels. U.S. Certification Codes:ANSI Z21.88/CSA 2.33 - Vented Gas Fireplace Heaters
Canadian Certification Codes:CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace
All Lyric appliances are CSA certified for indoor use only. Lyric appliances are not approved for outdoor installation. Appliances must be installed while maintaining required clearances as outlined in this manual. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliances are not approved for closet installation.
The appliance must be installed according to Lyric requirements in addition to any local codes that may apply, such as:
• USA: ANSI Z223.1/NFPA 54• Canada: CSA B149
All Built-In Lyric fireplaces require a heat release located within 6” of the draft stop.
Series 90-110: Minimum 124 sq. in. of free air spaceSeries 140: Minimum 200 sq. in. of free air space
For installation and framing requirements, please refer to the proper Lyric Installation Manual.
Gas Pressures & Heat Input
DetailsSubject
Natural Gas (NG) or Propane (LPG)Type of Gas
4/6" OR 5/8" Direct VentVent
Lyric ScreenHeat Barrier
Leave 20% burner and grill uncovered by mediaGeneral NoteInterior Design Media
111 Ibs.Three Sided Stand Alone 15" (40)
Weight162 Ibs.Three Sided Stand
Alone 30" (75)
202 Ibs.Three Sided 35" (90)
233 Ibs.Three Sided 43" (110)
ANSI Z21.88Z/CSA 2.33SafetyStandard
ANSI P.4.1-09Efficiency
Metrik Maxitrol Remote Control (Standard), Wall Switch (Optional)Operation
All models are provided with an AC Adapter, which requires on dedicated minimum 110 Volt, 20 Amp, 60 Hz, 2 gang outlet to be installed in the access panel area adjacent to the gas valve
Electrical Requirements
Series Three Sided Lyric Models Gas
Inlet Pressures Heat Input
Min. Max. Min. Max.
Three Sided Lyric
Series
Natural Gas (NG)
15"(40) NaturalGas (NG) 7.0" WC 11.0" WC 10,419
BTU/hr23,670BTU/hr
30"(75) NaturalGas (NG) 7.0" WC 11.0" WC 16,100
BTU/hr29,100BTU/hr
35"(90) NaturalGas (NG) 7.0" WC 11.0" W 14,461
BTU/hr33,127BTU/hr
43" (110) NaturalGas (NG) 7.0" WC 11.0" WC 22,800
BTU/hr37,100BTU/hr
Propane (LPG)
15"(40) Propane(LPG) 11.0" WC 13.0" WC 17,796
BTU/hr28,500BTU/hr
30"(75) Propane(LPG) 11.0" WC 13.0" WC 13,800
BTU/hr22,100BTU/hr
35"(90) Propane(LPG) 11.0" WC 13.0" WC 14,104
BTU/hr19,591BTU/hr
43" (110) Propane(LPG) 11.0" WC 13.0" WC 22,900
BTU/hr28,500BTU/hr
TECHNICAL INFORMATION See Through Lyric Series Product SpecificationsLyric direct vent gas appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP), and not for use with solid fuels. U.S. Certification Codes:ANSI Z21.88/CSA 2.33 - Vented Gas Fireplace Heaters
Canadian Certification Codes:CLASS 2901 84 – DOMESTIC HEATERS (GAS) Vented Fireplace – Certified to US Standard CLASS 2901 04 – DOMESTIC HEATERS (GAS) Vented Fireplace
All Lyric appliances are CSA certified for indoor use only. Lyric appliances are not approved for outdoor installation. Appliances must be installed while maintaining required clearances as outlined in this manual. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The appliances are not approved for closet installation.
The appliance must be installed according to Lyric requirements in addition to any local codes that may apply, such as:
• USA: ANSI Z223.1/NFPA 54• Canada: CSA B149
All Built-In Lyric fireplaces require a heat release located within 6” of the draft stop.
Series 90-110: Minimum 124 sq. in. of free air spaceSeries 140: Minimum 200 sq. in. of free air space
For installation and framing requirements, please refer tothe proper Lyric Installation Manual.
Gas Pressures & Heat Input
DetailsSubject
Natural Gas (NG) or Propane (LPG)Type of Gas
5/8" Direct VentVent
Lyric ScreenHeat Barrier
Leave 20% burner and grill uncovered by mediaGeneral NoteInterior Design Media
205 Ibs.See Through 43" (110)Weight
ANSI Z21.88Z/CSA 2.33SafetyStandard
ANSI P.4.1-09Efficiency
Metrik Maxitrol Remote Control (Standard), Wall Switch (Optional)Operation
All models are provided with an AC Adapter, which requires on dedicated minimum 110 Volt, 20 Amp, 60 Hz, 2 gang outlet to be installed in the access panel area adjacent to the gas valve
Electrical Requirements
Series See Through Lyric Models Gas
Inlet Pressures Heat Input
Min. Max. Min. Max.
SeeThrough
LyricSeries
Natural Gas (NG)
43"(110) NaturalGas (NG) 7.0" WC 11.0" WC 22,800
BTU/hr37,100BTU/hr
Propane (LPG)
43"(110) Propane(LPG) 11.0" WC 13.0" WC 22,900
BTU/hr28,500BTU/hr
For over three decades, Ortal has been redesigning fire. Now, we’re reimagining luxury with Lyric—our most accessible collection of direct vent gas fireplaces yet. Combining Ortal’s unwavering commitment to quality with an emphasis on value-engineered design and manufacturing, Lyric fireplaces bring luxury within reach.With Lyric, Ortal has pushed the envelope once again. We’ve listened to our valued customers and partners around the globe. As a result, we’ve reconceived our most popular fireplaces with an eye toward greater value, slimmer designs, easier installation, and more convenience. As always, you get the best materials, the most beautiful finishes, the highest safety standards, and the largest selection of high-quality contemporary frameless gas fireplaces anywhere in the world.
BY ORTAL
Have questions? Comments?Email: [email protected] us: 844-LYRIC-FIREWebsite: www.lyricfireplace.com
CONTACT US
Lyric110
Front