LFV300 Universal Limit Switch for Liquids

16
T The level sensors of the LFV300 series are universally usable limit switches that detect predefined filling heights in liquid systems with millimetre-accuracy – even under diffi- cult operating conditions. The measurement principle of the oscillating fork reacts to changes in density between the surrounding air and the liquid, and thus operates inde- pendently of the tank material, container structures or the liquid involved. The rugged sensor requires no calibration with the me- dium and operates without wear or mainte- nance. Area of use There are almost no restrictions to the device’s areas of use as a limit switch in tanks, storage and intermediate containers, or to protect pumps from dry-running – thanks to the universal measurement principle of the LFV300 and its flexible design. A tube-ex- tended variant for vertical mounting with up to 6 metres switching distance to the top of the container is also available – the LFV330. A wide selection of flange, threads and hygi- enic connections allow customer-specific so- lutions. The device is suitable for hygienic ap- plications and can be cleaned using SIP and CIP processes. There are also variants for use in potentially explosive atmospheres, to prevent overfilling (in compliance with WHG), and with marine certification. Advantages: Rugged device design Flexible concept allows customer- specific solutions, particularly in hygienic areas and Ex-zones Teaching without filling Very high reproducibility Level switch for full and empty messages Vibronic level switch The LFV300 universal limit switch for liquids – rugged and reliable measurement of liquids using the tuning fork principle D ATA SHEET

description

Sensor de nivel SICK

Transcript of LFV300 Universal Limit Switch for Liquids

Page 1: LFV300 Universal Limit Switch for Liquids

TThe level sensors of the LFV300 series are

universally usable limit switches that detect

predefined filling heights in liquid systems

with millimetre-accuracy – even under diffi-

cult operating conditions. The measurement

principle of the oscillating fork reacts to

changes in density between the surrounding

air and the liquid, and thus operates inde-

pendently of the tank material, container

structures or the liquid involved. The rugged

sensor requires no calibration with the me-

dium and operates without wear or mainte-

nance.

Area of use

There are almost no restrictions to the

device’s areas of use as a limit switch in

tanks, storage and intermediate containers,

or to protect pumps from dry-running – thanks

to the universal measurement principle of

the LFV300 and its flexible design. A tube-ex-

tended variant for vertical mounting with up

to 6 metres switching distance to the top of

the container is also available – the LFV330.

A wide selection of flange, threads and hygi-

enic connections allow customer-specific so-

lutions. The device is suitable for hygienic ap-

plications and can be cleaned using SIP and

CIP processes. There are also variants for

use in potentially explosive atmospheres, to

prevent overfilling (in compliance with WHG),

and with marine certification.

Advantages:

� Rugged device design

� Flexible concept allows customer-

specific solutions, particularly in

hygienic areas and Ex-zones

� Teaching without filling

� Very high reproducibility

Level switch for full and empty messages

Vibronic level switch

The LFV300 universal limit switch for liquids – rugged and reliable measurement of liquids using the tuning fork principle

Da

ta

sh

ee

t

Page 2: LFV300 Universal Limit Switch for Liquids

2 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

LFV300

Fault monitoringThe electronics module of LFV300 monitors continuouslythe following criteria:

� Strong corrosion or damage on the tuning fork

� Loss of vibration

� Line break to the piezo drive

Type overview

LFV310 LFV330

Attributes

Preferred application: Liquids Liquids

Length: - 80… 6000 mm (3.15… 236.22 in)tube extention

Process connection: Thread G¾ A, G1 A, flanges, hygienicfittings

Thread G¾ A, G1 A, flanges, hygienicfittings

Process temperature: -50… +150°C (-58… +302 °F)-50… +250°C (-58… +482 °F) with temperature adapter

-50… +150°C (-58… +302 °F)-50… +250°C (-58… +482 °F) withtemperature adapter

Process pressure: -1 … 64 bar (-14.5… 928 psi) -1 … 64 bar (-14.5… 928 psi)

Signal output: Relay, transistor, NAMUR output, contactless electronic switch

Relay, transistor, NAMUR output, contactless electronic switch

Housing types

1 Plastic housing2 Aluminium housing3 Stainless steel

1 2 3

Page 3: LFV300 Universal Limit Switch for Liquids

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 3 Subject to change without notice.

LFV300LFV300

Technical data

Electric data Process pressure –1 … 64 bar Process temperature -50 ... 150°C (optional 250°C) Fill material density > 0,5 ... 2.5g/cm3

Viscosity 0.1 … 10000 mPas Materials, non-wetted parts 1.4404 (Optional Ra < 0,8 μm) Material, housing Aluminium, plastic, stainless steel Response time 500 msProcess connection G ¾”, G1”, flange, triclamp, pipe connection DIN 11851 (further see type code)Accuracy ± 2 mmReproducibility ± 1 mmHysteresis switching output 2 mmTemperature drift 0,03 mm/KAmbient temperature operation –40 … +70 °CAmbient temperature storage –40 … +80 °CEnclosure rating IP 66/ 67 or IP 66/IP68 (0.2bar)Length (only for LFV330) 80mm ... 6.000mm tube extension

Electronic (Version T) Electronic (Version C)Switching output Transistor output Contactless electronic switchSignal voltage HIGH UV – 3 VSignal voltage LOW < 1VOutput current IA < 300 mA < 400 mAOutput loadCapacitive load 100 nF 100 nFInductive load 1 H 1 HSupply voltage 10 … 55 VDC 20 ... 253V AC/DCResidual ripple ≤ 5 VPP

Current consumption < 10 mA < 4.2 mAInitialization time < 2 s < 3 sProtection class

Electronic (Version R) Electronic (Version N)Switching output Relay output Namur output Output current IA >10uA; <3A AC, 1A DC 1mA / 2,5mA Output load Capacitive load 750VA 54WInductive load 750VA 54WSupply voltage 20 ... 253VAC; 20 ... 72 V DC 4,5 ... 12 V DCCurrent consumption 5 ... 30mA 1mA / 2,5mA Initialization time < 2 s < 2 sProtection class

Approvals Overfill protection according to WHGATEX ATEX II 1G, 1/2G, 2G Ex ia IIC T6 ATEX II 1/2G, 2G Ex d IIC T6Marine certification GL

EHEDG-certificationFDA-conformity

Page 4: LFV300 Universal Limit Switch for Liquids

Dimensions

LFV310

G¾A, ¾"NPTG1A, 1"NPT

18,5

32 (G¾A, ¾"NPT)41 (G1A, 1"NPT)

57

50

ø 33,7

3619

5353

53

55G¾

=66

G1=

69

� �

� �

4 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

Electrical Connection

1. Preparing the connectionNote safety instructions Always keep in mind the following safety instructions:

� Connect only in the complete absence of line voltageTake note of safety instructions for Ex applications

In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units.

In hazardous areas, only use approved cable connections for LVF310/330.

Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications.

1 Thread2 Tri-Clamp3 Cone DN 254 Bolting DN 405 FlangeL Sensor length, see chapter „Technical data“

LFV300

Temperature adapter - LFV310/330

1 Thread2 Tri-Clamp3 Cone DN 254 Bolting DN 405 Flange

LFV330

G 3/4 A, 3/4" NPTG 1 A, 1" NPT

L

L

LL

L

32 (G

3/ 4

A, 3

/ 4" N

PT)

41 (G

1 A

, 1" N

PT)

� �

� �

18.5

57

50

ø 33,7

3619

Page 5: LFV300 Universal Limit Switch for Liquids

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 5 Subject to change without notice.

2. Wiring plan

Relay output

We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).

The relays are always shown in non-operative condition.

LFV300 - oscillator with relay output

1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment

LFV300 - wiring plan - relay output

1 Relay output2 Relay output3 Voltage supply

Transistor output

We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).

The instrument is used to control relays, contactors, magnetvalves, warning lights, horns as well as PLC inputs.

LFV300 - oscillator with transistor output

1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment

LFV300 transistor output - NPN action

LFV300 transistor output - PNP action

LFV300LFV300

Page 6: LFV300 Universal Limit Switch for Liquids

6 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

Contactless electronic switch

We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).

The contactless electronic switch is always shown in non-operative condition.

The instrument is used for direct control of relays, contactors,magnet valves, warning lights, horns etc. It must not be operated without an intermediately connected load, because the electronics would be destroyed if connected directly to the mains. It is not suitable for connection to low voltage PLC inputs.Domestic current is temporarily lowered below 1mA after switching off the load so that contactors, whose holding current is lower than the constant domestic current of the electronics, are reliably switched off.

When LFV300 is used as part of an overfill protection system according to WHG, also note the regulations of the general type approval.

LFV300 - oscillator with contactless electronic switch

1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment

LFV300 - wiring plan - output, contactless electronic switch

NAMUR output

LFV300 - oscillator with NAMUR electronics

1 Control lamp2 DIL switch for characteristics reversal3 DIL switch for sensitivity adjustment4 Simulation keyFor connection of the amplifier according to NAMUR(IEC 60947-5-6, EN 50227).

LFV300 - Wiring plan - NAMUR output

Simulation keyThe simulation key is located in a recess on the upper side of the oscillator. Push the simulation key with a suitable object (screwdriver, pen, etc.).When the key is pushed, a line break between sensor and processing unit is simulated. The signal lamp on the sensor extinguishes. The measuring system must signal a fault and take on a safe condition when the key is pushed.Keep in mind that downstream connected instruments will be activated during operation. This allows you to check the correct function of the measuring system.

Characteristics reversalThe characteristics of the NAMUR electronics can be reversed with the DIL switch. You can choose between falling characteristic curve (switch position max.) and rising characteristic curve (switch position min.). You can thus have the desired current outputted.Modes:

�min. - rising characteristic curve (High current when immersed) �max. - falling characteristics (Low current when immersed)

The NAMUR-output can be switched to falling or rising characteristics.For applications according to WHG, the DIL switch must be set toposition max..

LFV300

NAMUR-amplifier

Page 7: LFV300 Universal Limit Switch for Liquids

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 7 Subject to change without notice.

Mounting instructions

Switching pointIn general, LFV300 can be installed in any position. The instrument simply has be mounted in such a way that the vibrating element is at the height of the desired switching point.

The tuning fork has lateral markings (notches) marking the switching point with vertical installation. The switching point refers to the medium water with basic setting of the density switch ≥ 0.7g/cm³ (0.025 lbs/in³).

Keep in mind that foams with a density > 0.45 g/cm³ (0.016 lbs/in³) are detected by the sensor.

SocketThe vibrating element should protrude into the vessel to avoid build-up. For that reason, avoid using mounting bosses for flanges and screwed fittings. This applies particularly for horizontal installation and with adhesive products.

AgitatorsDue to agitators, vibrations or similar, the level switch can be subjected to strong lateral forces. For this reason, do not use an overly long extension tube for LFV330, but check if you can mount a LFV200 or LFV310 level switch on the side of the vessel in horizontal position.

Extreme vibration caused by the process or the equipment, e.g.agitators or turbulence in the vessel, can cause the extension tube of LFV300 to vibrate in resonance. This leads to increasedstress on the upper weld joint. Should a longer tube version be necessary, you can provide a suitable support or guy directly above the vibrating element to secure the extension tube.

This measure applies particularly to applications in Ex areas. Make sure that the tube is not subjected to bending forces through this measure.

Inflowing mediumIf LFV300 is mounted in the filling stream, unwanted mismeasurements may result. Mount LFV300 at a location in the vessel where no disturbing influence from e.g. filling openings, agitators, etc. can occur.

FlowsTo minimise flow resistance caused by the tuning fork, LFV300 should be mounted in such a way that the surfaces of the blades are parallel to the product movement.

LFV300LFV300

Page 8: LFV300 Universal Limit Switch for Liquids

8 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

Deviation ±1 mm (0.04 in)

Influence of the process temperature on the switching point

1 Shifting of the switching point in mm (in)2 Process temperature in °C (°F)3 Switching point at reference conditions (notch)4 Tuning fork

Influence of the product density on the switching point

1 Shifting of the switching point in mm (in)2 Product density in g/cm³ (lb/in³)3 Switch position 0.5 g/cm³ (0.018 lb/in³)4 Switch position 0.7 g/cm³ (0.025 lb/in³)5 Switching point at reference conditions (notch)6 Tuning fork

Measuring accuracy

LFV300

Page 9: LFV300 Universal Limit Switch for Liquids

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 9 Subject to change without notice.

Influence of the process pressure to the switching point

1 Shifting of the switching point in mm (in)2 Process pressure in bar (psi)3 Switching point at reference conditions (notch)4 Tuning fork

Ambient temperature - Product temperature

1 Product temperature2 Ambient temperature3 Temperature range with temperature adapter

Repeatability 0.1 mm (0.004 in)Hysteresis approx. 2 mm (0.08 in) with vertical installationSwitching delay approx. 500 ms (on/off)Frequency approx. 1200 Hz

LFV300LFV300

Page 10: LFV300 Universal Limit Switch for Liquids

1 0 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

LFV300

LFV310 –

Approvalwithout approvalOverfill protection acc. to WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + WHGATEX II 1/2G, 2G Ex d IIC T6 + WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + marine certificationATEX II 1/2G, 2G Ex d IIC T6 + marine certification Marine certification GL

Process fitting / MaterialThread G¾ A PN64 / 316LThread ¾ NPT PN64 / 316LThread G1 A PN64 / 316LThread 1 NPT PN64 / 316LTri-Clamp 1“ PN16 / 316L Ra<0.8µmTri-Clamp 2“ PN16 / 316L Ra<0.8µmTri-Clamp 3“ PN16 / 316L Ra<0.8µmBolting DN40 PN40 DIN11851 / 316L Ra<0,8µmVarivent N50-40 / 316L Ra<0,8µmDRD-Flange PN40/316L ZB3007Flange DN25 PN40 Form C, DIN 2501 / 316LFlange DN50 PN40 Form C, DIN 2501 / 316LFlange DN40 PN40 Form C,DIN 2501/ 316LFlange DN80 PN40 Form C,DIN 2501/ 316LFlange 1“ 150lb RF, ANSI B16.5 / 316LFlange 2“ 150lb RF, ANSI B16.5 / 316Lothers on request

Adapter / Process temperaturewithout / -50...150°Cwith / -50...250°C

HousingPlastic IP 66/ 67 / M20x1.5Plastic IP 66/ 67 / ½“ NPTPlastic IP 66/ 67 / Plug M12x1 (4-pin) Plastic IP 66/ 67 / Plug M12x1 (5-pin)Plastic IP 66/ 67 / Plug M12x1(5-pin; EN50044) Plastic IP 66/ 67 / Plug M12x1(4-pin; EN50044) Aluminium IP 66/IP67 / M20x1.5Aluminium IP 66/IP67 / ½“ NPT Aluminium IP 66/ 67 / Plug M12x1 (4-pin)StSt (electropolished) 316L / IP 66/IP67 / M20x1.5StSt (electropolished) 316L / IP 66/IP67 / ½“ NPT ElectronicsContactless electronic switch 20...250 V AC/DCDouble relay (DPDT) 20...72 V DC/20...250 V AC (3A)Transistor (NPN/PNP) 10...55 V DCNAMUR signalSwitching pointStandardSwitching point prolongued 118 mm

XT

CRTN

XL

XXCDCDX

XAAAMMM

GNGNCCCR

BBAACAEA

VVVVPPPP

TDFFFFAA

AAPECIPC

PVVVVVVV

Type code

P

WYDMUZ89

NT

Page 11: LFV300 Universal Limit Switch for Liquids

Order Information

Housing Process conection Electronics Model name Part no.

Plastic IP 66/ 67/ M20x1,5

Thread G ¾ A PN64

Contactless switch 20...250 V AC/DCLFV310-XXGBVTPCX 6037999

LFV310-XXGBVXPCX 6037990

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV310-XXGBVTPRX 6038002

LFV310-XXGBVXPRX 6037993

Transistor (NPN/PNP) 10...55 V DCLFV310-XXGBVTPTX 6037996

LFV310-XXGBVXPTX 6037888

Thread ¾“ NPT PN64Relay (DPDT) 20...72 V DC/

20...250 V AC (3A)LFV310-XXNBVXPRX 6038972

Aluminium IP 66/IP67/ M20x1,5

Thread G ¾ A PN64

Contactless switch 20...250 V AC/DCLFV310-XXGBVXMCX 6037989

LFV310-XXGBVTMCX 6037998

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV310-XXGBVXMRX 6037991

LFV310-XXGBVTMRX 6038000

Transistor (NPN/PNP) 10...55 V DCLFV310-XXGBVXMTX 6037751

LFV310-XXGBVTMTX 6037994

Thread G 1 A PN64Relay (DPDT) 20...72 V DC/

20...250 V AC (3A)LFV310-XXGAVXMRX 6039134

StSt (electropolished)316L / IP 66/IP67/

M20x1,5Thread G ¾ A PN64

Contactless switch 20...250 V AC/DCLFV310-XXGBVX8CX 6037916

LFV310-XXGBVT8CX 6037997

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV310-XXGBVT8RX 6038001

LFV310-XXGBVX8RX 6037992

Transistor (NPN/PNP) 10...55 V DC

LFV310-XXGBVT8TX 6037995

LFV310-XXGBVX8TX 6037752

Plastic IP 66/ 67/ Plug M12x1 (4-pin) Thread G 1 A PN64 LFV310-XXGAVXTTX 6039737

Plastic IP 66/ 67/ Plug M12x1 (5-pin) Thread G ¾ A PN64 LFV310-XXGBVXWTX 6039061

The displayed part numbers are only an extract of the possible variations. You find further part numbers on www.mysick.com or contact your SICK-sales person.

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 1 Subject to change without notice.

LFV300LFV300

Page 12: LFV300 Universal Limit Switch for Liquids

1 2 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

LFV300

Type code

P

WYDMUZ89

NT

LFV330 –

Approvalwithout approvalOverfill protection acc. to WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + WHGATEX II 1/2G, 2G Ex d IIC T6 + WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + marine certificationATEX II 1/2G, 2G Ex d IIC T6 + marine certification Marine certification GL

Process fitting / MaterialThread G¾ A PN64 / 316LThread ¾ NPT PN64 / 316LThread G1 A PN64 / 316LThread 1 NPT PN64 / 316LTri-Clamp 1“ PN16 / 316L Ra<0.8µmTri-Clamp 2“ PN16 / 316L Ra<0.8µmTri-Clamp 3“ PN16 / 316L Ra<0.8µmPipe connection DN40PN40 DIN11851 / 316L Ra<0,8µmVarivent N50-40 / 316L Ra<0,8µmDRD-Flange PN40/316L ZB3007Flange DN25PN40 Form C, DIN 2501 / 316LFlange DN50PN40 Form C, DIN 2501 / 316LFlange DN40PN40 Form C,DIN 2501/316LFlange DN80PN40 Form C,DIN 2501/316LFlange 1“ 150lb RF, ANSI B16.5 / 316LFlange 2“ 150lb RF, ANSI B16.5 / 316Lothers on request

Adapter / Process temperaturewithout / -50...150°Cwith / -50...250°C

HousingPlastic IP 66/ 67 / M20x1.5Plastic IP 66/ 67 / ½NPTPlastic IP 66/ 67 / Plug M12x1 (4-pin) Plastic IP 66/ 67 / Plug M12x1 (5-pin)Plastic IP 66/ 67 / Plug M12x1(5-pin; EN50044) Plastic IP 66/ 67 / Plug M12x1(4-pin; EN50044) Aluminium IP 66/IP67 / M20x1.5Aluminium IP 66/IP67 / ½ NPT Aluminium IP 66/ 67 / Plug M12x1 (4-pin)StSt (electropolished) 316L / IP 66/IP67 / M20x1.5StSt (electropolished) 316L / IP 66/IP67 / ½NPTElectronicsContactless electronic switch 20...250 V AC/DCDouble relay (DPDT) 20...72 V DC/20...250 V AC (3A)Transistor (NPN/PNP) 10...55 V DCNAMUR signalLength min. 80mm max. 6000mm

XXCDCDX

XAAAMMM

XT

CRTN

X

0 0 0 0

GNGNCCCR

BBAACAEA

VVVVPPPP

TDFFFFAA

AAPECIPC

PVVVVVVV

Page 13: LFV300 Universal Limit Switch for Liquids

Housing Process conection Electronics Model name Part no.

Plastic IP 66/ 67 (M20x1,5)

Thread G ¾ A PN64

Contactless switch 20...250 V AC/DC LFV330-CMGBVXPCX0160 6040971

Namur LFV330-CMGBVXPNX0160 6039512

Relay (DPDT)

LFV330-XXGBVXPRX0300 6039663

LFV330-XXGBVXPRX0500 6039661

LFV330-XXNBVXPRX0100 6038973

Thread ¾“ NPT PN64Contactless switch 20...250 V AC/DC

LFV330-DMGBVXMCX0160 6040973

Aluminium IP 66/IP67 (M20x1,5)

Thread G ¾ A PN64

LFV330-DAGBVXMCX0500 6039736

Namur LFV330-DMGBVXMNX0160 6040972

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV330-XXGBVXMRX0200 6039665

LFV330-DAGBVXMRX0300 6041182

LFV330-XXGBVXMRX1200 6041285

LFV330-DAGBVXMRX3000 6039761

Transistor (NPN/PNP) 10...55 V DC

LFV330-XXGBVXMTX0100 6039668

LFV330-XXGBVXMTX0100 6039668

Thread ¾“ NPT PN64 LFV330-XXNBVXMTX0500 6039667

Thread G 1 A PN64

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV330-XXGAVXMRX1300 6039693

LFV330-XXGAVXMRX1600 6039692

LFV330-XXGAVXMRX2000 6039691

LFV330-XXGAVXMRX0900 6039694

Transistor (NPN/PNP) 10...55 V DC LFV330-XXGAVXMTX0300 6039666

Relay (DPDT) 20...72 V DC/20...250 V AC (3A)

LFV330-XXGBVX8RX0300 6039664

StSt (electropolished) 316L / IP 66/IP67

(M20x1,5)Thread G ¾ A PN64

LFV330-XXGBVX8RX0500 6039662

Transistor (NPN/PNP) 10...55 V DC

LFV330-XXGBVX8TX0150 6041341

LFV330-XXGBVX8TX0100 6039669

LFV330-XXNBVX8TX0200 6039670

The displayed part numbers are only an extract of the possible variations. You find further part numbers on www.mysick.com or contact your SICK-sales person.

Order Information

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 3 Subject to change without notice.

LFV300LFV300

Page 14: LFV300 Universal Limit Switch for Liquids

1 4 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.

Accessoriers

LFV300

Plug connector, M8, 4-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M8, Enclosure rating IP 67

PVC2 m DOL-0804-G02M 6009870

5 m DOL-0804-G05M 6009872

PUR halogenfree

2 m DOL-0804-G02MC 6025894

5 m DOL-0804-G05MC 6025895

Plug connector, M12, 4-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M12,Enclosure rating IP 67

PVC2 m DOL-1204-G02M 6009328

5 m DOL-1204-G05M 6009866

PUR halogenfree

2 m DOL-1204-G02MC 6025900

5 m DOL-1204-G05MC 6025901

Food & Beverage

2 m DOL-1204-G02MN 6028128

5 m DOL-1204-G05MN 6028130

Plug connector, M12, 8-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M12,Enclosure rating IP 67

PVC2 m DOL-1205-G02M 6008899

5 m DOL-1205-G05M 6009868

PUR halogenfree

2 m DOL-1205-G02MC 6025906

5 m DOL-1205-G05MC 6025907

Power supply

Description Part no.

Power supply, 100 ... 240 V AC/24 V DC, 2.1 A, IP 20 6008899

Electronic module

Design Part no.

Contactless electronic switch 20 ... 250 V AC/ V DC 6038669

Double relay (DPDT) 20 ... 72 V DC / 20 ... 250 V AC 6038671

Transistor output (NPN/PNP) 10 ... 55 V DC 6038672

Namur output 6038670

Lock nut fitting

Design Model name Part no.

-1 ... 64 bar, LFV330 with G ¾ A thread G 1 A / 316 L BEF-MU-316G10-ALFV 5322463

Page 15: LFV300 Universal Limit Switch for Liquids

8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 5 Subject to change without notice.

Notes

LFV300LFV300

Plug connector, M8, 4-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M8, Enclosure rating IP 67

PVC2 m DOL-0804-G02M 6009870

5 m DOL-0804-G05M 6009872

PUR halogenfree

2 m DOL-0804-G02MC 6025894

5 m DOL-0804-G05MC 6025895

Plug connector, M12, 4-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M12,Enclosure rating IP 67

PVC2 m DOL-1204-G02M 6009328

5 m DOL-1204-G05M 6009866

PUR halogenfree

2 m DOL-1204-G02MC 6025900

5 m DOL-1204-G05MC 6025901

Food & Beverage

2 m DOL-1204-G02MN 6028128

5 m DOL-1204-G05MN 6028130

Plug connector, M12, 8-pin, straight

Connector type Sheath material Cable length Model name Part no.

Connector M12,Enclosure rating IP 67

PVC2 m DOL-1205-G02M 6008899

5 m DOL-1205-G05M 6009868

PUR halogenfree

2 m DOL-1205-G02MC 6025906

5 m DOL-1205-G05MC 6025907

Power supply

Description Part no.

Power supply, 100 ... 240 V AC/24 V DC, 2.1 A, IP 20 6008899

Electronic module

Design Part no.

Contactless electronic switch 20 ... 250 V AC/ V DC 6038669

Double relay (DPDT) 20 ... 72 V DC / 20 ... 250 V AC 6038671

Transistor output (NPN/PNP) 10 ... 55 V DC 6038672

Namur output 6038670

Lock nut fitting

Design Model name Part no.

-1 ... 64 bar, LFV330 with G ¾ A thread G 1 A / 316 L BEF-MU-316G10-ALFV 5322463

Page 16: LFV300 Universal Limit Switch for Liquids

AustraliaPhone +61 3 9497 4100 1800 33 48 02 – tollfreeE-Mail [email protected]

Belgium/LuxembourgPhone +32 (0)2 466 55 66E-Mail [email protected]

BrasilPhone +55 11 3215-4900E-Mail [email protected]

Ceská RepublikaPhone +420 2 57 91 18 50E-Mail [email protected]

ChinaPhone +852-2763 6966E-Mail [email protected]

DanmarkPhone +45 45 82 64 00E-Mail [email protected]

DeutschlandPhone +49 211 5301-301E-Mail [email protected]

EspañaPhone +34 93 480 31 00E-Mail [email protected]

FrancePhone +33 1 64 62 35 00E-Mail [email protected]

Great BritainPhone +44 (0)1727 831121E-Mail [email protected]

IndiaPhone +91–22–4033 8333E-Mail [email protected]

IsraelPhone +972-4-999-0590E-Mail [email protected]

ItaliaPhone +39 02 27 43 41E-Mail [email protected]

JapanPhone +81 (0)3 3358 1341E-Mail [email protected]

NederlandsPhone +31 (0)30 229 25 44E-Mail [email protected]

Norge Phone +47 67 81 50 00E-Mail [email protected]

ÖsterreichPhone +43 (0)22 36 62 28 8-0E-Mail [email protected]

PolskaPhone +48 22 837 40 50E-Mail [email protected]

Republic of KoreaPhone +82-2 786 6321/4E-Mail [email protected]

Republika SlowenijaPhone +386 (0)1-47 69 990E-Mail [email protected]

RomâniaPhone +40 356 171 120 E-Mail [email protected]

RussiaPhone +7 495 775 05 34E-Mail [email protected]

SchweizPhone +41 41 619 29 39E-Mail [email protected]

SingaporePhone +65 6744 3732E-Mail [email protected]

SuomiPhone +358-9-25 15 800E-Mail [email protected]

SverigePhone +46 10 110 10 00E-Mail [email protected]

TaiwanPhone +886 2 2375-6288E-Mail [email protected]

TürkiyePhone +90 216 587 74 00E-Mail [email protected]

USA/Canada/MéxicoPhone +1(952) 941-6780 1 800-325-7425 – tollfreeE-Mail [email protected]

SICK AG | Waldkirch | Germany | www.sick.com

8013

170/

2010

-02-

01 /

FD ∙

Prin

ted

in G

erm

any

(201

0-10

) ∙ S

ubje

ct to

cha

nge

with

out n

otic

e ∙ T

he s

peci

fied

prod

uct f

eatu

res

and

tech

nica

l dat

a do

not

repr

esen

t any

gua

rant

ee ∙

01 U

S m

odifi

ed 4

c in

t32