Use of Engineered Phase Change Materials in Cold Chain Packaging Design
Presented By:Anthony Alleva
Technical Services Manager, TCP Reliable, Inc.Healthcare Packaging Conference & Workshops
May 27, 2010
Leveraging New Refrigerant Technologies
2 www.cryopak.com
Table of Contents
PCM Science
PCM Selection and Design
Other Considerations
Package Design Case Studies
3 www.cryopak.com
Temperature Controlled Packaging 101
The purpose of a temperature controlled package is to maintain an interior thermal environment sufficient to meet the product’s temperature requirements.
Refrigerant packs in combination with insulated containers make up the bulk of temperature controlled packages.
The most commonly employed refrigerant material is water often with some additives to alter its properties.
4 www.cryopak.com
Solid – Liquid - Gas
Phase change is when a material changes between the states of matter.
Phase changes can require large amounts of energy to occur.
Common terms:• Melting and Freezing• Evaporation• Condensation
5 www.cryopak.com
“Frozen” means “Solid” not “Cold”!
Anything that is in its “solid state” of matter is correctly referred to as “frozen”.
Materials generally have temperatures at which they transition from solid to liquid and liquid to gas but a small percentage of them are at temperatures that humans normally experience.
6 www.cryopak.com
Enthalpy of Fusion
The Enthalpy of Fusion is the amount of thermal energy which must be absorbed or released for a substance to change state from solid to liquid or liquid to solid.• Often also referred to as the
Latent Heat of Fusion
While a material is melting or freezing it stays constant at its phase change temperature.
This property is used to control the temperature inside of the package.
MaterialMelting Point
(°C)
Enthalpy of
Fusion
(kJ/kg)
Helium -269.65 5.23
Hydrogen -259.31 58.6
Nitrogen -209.97 25.5
Oxygen -218.79 13.8
Ethyl Alcohol -114 104.2
Mercury -39 11.8
Water 0 334
Sulfur 119 38.1
Lead 327.3 24.5
Antimony 630.5 165
Silver 960.8 88.3
Gold 1063 64.5
Copper 1083 134
7 www.cryopak.com
Why Water?
Water is a common material used in refrigerant packs as it is relatively cheap and ubiquitous.
Water undergoes its solid to liquid phase change at 0 °C / 32 °F which is useful for keeping items “cold”.
Water has a relatively high level of heat capacity as it goes through its freezing and thawing process and can be relied upon to maintain that 0 °C temperature for long periods of time.
8 www.cryopak.com
Phase Change Materials (PCM’s)
A PCM is a material chosen for use in an application due to its phase change properties. Normally it is the solid-liquid phase change that is utilized.
While water is correctly referred to as a Phase Change Material, the packaging industry usually excludes water from the category when discussing PCM’s.
The goal is to match the phase change temperature with the product temperature requirements as the PCM will naturally maintain that temperature while melting or freezing.
9 www.cryopak.com
PCM Selection
First and foremost a PCM must have a phase change temperature within the desired range and ideally centered within the range.
If the temperature range has only one limit the PCM temperature should be near the limit but still within the range.
Should have performance characteristics that allow it to be a reasonable replacement for water.
Product
Temperature
Range
PCM Temperature
2°C to 8°C 5°C
15°C to 30°C 22°C
-10°C to 10°C 0°C
Below 30°C 25°C to 28°C
Below -10°C -25°C to -15°C
10 www.cryopak.com
Water is the Standard of Comparison
Most current temperature control packaging applications are using water as the PCM and as a results, the industry has become used to those systems.• Water has:
• Consistent, repeatable, reliable phase change temperature. • High Enthalpy of Fusion, long time to melt.• Safe, Non-Toxic (Inhalation of large amounts is fatal though)• Easily packaged into “gel packs” or “cold pack bottles”.• Very inexpensive and easy to obtain.
• A “good” PCM will mimic these properties but change phase at a desired temperature.
11 www.cryopak.com
When Designing a PCM
Use a Pure Chemical• Search published tables of Phase Change
temperatures for chemicals that have natural Phase Change temperatures within the desired range.
• Cull out materials that have undesirable qualities:• Have low Enthalpies of Fusion or Human Toxicity.• Cannot be easily purchased or manufactured into a
refrigerant.• Are too expensive to be feasible in a packaging application.
12 www.cryopak.com
Case Study:Deuterium Oxide
D20 (Also known as Heavy Water) is water that contains a very high (99%+) concentration of the deuterium isotope. Best known for its use in nuclear fusion reactors.
Phase Change Temperature: Approximately 4°C, Repeatability expected to be high.
Enthalpy of Fusion: A small amount greater than regular water.
Toxicity: Low (drinking very large quantities results in death).
Packaging: Can be contained in any material that can contain water.
Ease of Manufacture: Exists in all water at approximately 0.03% by weight. Just needs to be distilled through electrolysis. 400 gallons of water yields 1lb of D20.
Cost: Approximately $100 per 0.25 lbs.
13 www.cryopak.com
Designing a PCM
Use a Mixture of Two (or more) Chemicals
Binary Phase Diagram is a graph of the phase change temperature of a mixture of two chemicals showing the relationship between the relative concentrations and the phase states.
The Eutectic Point is the temperature and concentration that the mixture crystallizes simultaneously.
(Diagram from http://www.uwgb.edu/dutchs/petrolgy/BEUTECT.HTM)
Eutectic Point
14 www.cryopak.com
Case Study:Water / Ethylene Glycol Mixture
Water mixed with Ethylene Glycol is commonly referred to as “antifreeze” and is used in cars as the engine coolant.
Phase Change Temperature: Eutectic Point is approximately -50°C at just under 60% Ethylene Glycol concentration.
Enthalpy of Fusion: Ethylene Glycol is 160 kJ/kg and water is 334 kJ/Kg (mixture will be between those values).
Toxicity: Moderate to Low (drinking Ethylene Glycol can in death but is mitigated by water). (Diagram from
http://www.uwgb.edu/dutchs/petrolgy/BEUTECT.HTM)
15 www.cryopak.com
Case Study:Water / Ethylene Glycol Mixture
Packaging: Can be contained in any material that can contain water.
Ease of Manufacture: Antifreeze is very commonly available.
Cost: Approximately $0.50 per pound. (Diagram from
http://www.uwgb.edu/dutchs/petrolgy/BEUTECT.HTM)
16 www.cryopak.com
The T Problem: Time to Freeze/Melt
This equation can be used to calculate heat absorption:
The amount of heat absorbed is proportional to the difference (delta) in temperature between the phase change and the environment.
Higher offsets in temperature will result in faster energy flow resulting in faster phase changes.
17 www.cryopak.com
Experimental Example: The T Problem
Compare the Phase Change of Three PCM’s Materials chosen:
• Water Gel: Phase Change at 0°C• Phase 5: Phase Change at 5°C• Phase 22: Phase Change at 22°C
Test Set-Up• Cube of PCM encased in Cube of Polystyrene• Freeze/Thaw all three samples and monitor the
temperatures of each
18 www.cryopak.com
Photo of Cube Test Set-Up
19 www.cryopak.com
Result for Freezing
Comparison of Freezing of Three PCM's
-40
-30
-20
-10
0
10
20
30
40
0 6 12 18 24 30 36 42 48
Time(h)
Te
mp
era
ture
(°C
)
Ambient Phase 5 Water Gel Phase 22
20 www.cryopak.com
Result for Melting
Comparison of Melting of Three PCM's
-40
-30
-20
-10
0
10
20
30
40
48 54 60 66 72 78 84 90 96
Time(h)
Te
mp
era
ture
(°C
)
Ambient Phase 5 Water Gel Phase 22
21 www.cryopak.com
Conclusions from Experiment : The T Problem
The ambient temperature is a large factor in time to freeze or melt of a PCM.
The closer the ambient temperature is to the PCM’s melting point the longer it will last.
Once a PCM completes its phase change it has little ability to absorb energy.
22 www.cryopak.com
Dry Ice: A Special Case
Dry Ice is Carbon Dioxide in its Frozen State
The phase change it undergoes is called “Sublimation” which means it changes phase directly from solid to gas, skipping the liquid phase.
Dry Ice is made by cooling and pressurizing CO2
Phase Change Temperature is -78.5°C
Cost is around $1 to $2 a pound.
23 www.cryopak.com
Dry Ice: Breaking the Law
Very difficult to store• To prevent it from sublimating it would need to be kept in a freezer
maintaining below -78.5°C or kept under pressure.• As it sublimates it turns into gas which is difficult to capture and reuse.
Dry Ice is considered a shipping hazard• CO2 replaces oxygen in the human body as it is inhaled causing
unconsciousness.• There are regulations on how much can be shipped on an airplane.
Sublimation of the Dry Ice inside of a package cause empty space.• The package must be designed to survive the loss of its contents from a
shock and vibration perspective.
24 www.cryopak.com
Dry Ice: Mitigating Factors
Dry Ice has a very high Enthalpy of Sublimation at 571 kJ/kg. (Water’s Enthalpy of Fusion is 334 kJ/kg)
The high heat capacity makes up somewhat for the high T of the -78.5°C phase change temperature.• Compare to water:
• 517/334 = 1.7x• (20- - 78.5)/(20-0) = 4.9
• Ratio of weights = 2.9 lbs of Dry Ice vs. 1 lb of water.
Dry Ice is inexpensive and common ($1-$2 per lb).
From an environmental waste perspective, Dry Ice is a wonderful material as it naturally turns into “air” as opposed to “garbage”.
25 www.cryopak.com
Dry Ice Performance Example
Example Dry Ice Temperature Profile
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
0 6 12 18 24 30 36 42 48 54 60
Time(h)
Te
mp
era
ture
(°C
)
18 lbs of Dry Ice Ambient
26 www.cryopak.com
Other Considerations: Insulation
Passive temperature control can only be achieved if something in the packaging system naturally controls its temperature.
The PCM’s role in the temperature controlled package is to provide the energy for the system and act as the temperature regulator.
The performance of the PCM cannot be uncoupled from the packaging system.
27 www.cryopak.com
Experiment: Insulation Quality and Freeze Time
Test Set-Up• All Containers included one (1) 8” x 8” Bag, 2 lb Gel
Pack with the Thermocouple placed inside the bag at the center of the gel.
• All containers had an outer dimension of 12”x12”x12”• Empty Corrugated RSC Box• Expanded Polystyrene Lined RSC • Vacuum Insulated Panel Lined RSC
Question• What relationship does package insulation have to the
time it takes a gel pack to freeze?
28 www.cryopak.com
Insulation Quality vs. Time
Comparison of Freezing within 3 Insulations
-30
-20
-10
0
10
20
30
0 12 24 36 48 60 72 84 96
Time(h)
Te
mp
era
ture
(°C
)
Empty Box EPS Box VIP Box Ambient
29 www.cryopak.com
Other Considerations: Combining PCM’s
PCM’s with different phase change temperatures can be used together to result in performance that neither would have alone.
Example: Temperature Range of 0°C to 30°C• Use a liquid state 5°C PCM in combination with a solid state 25°C PCM.• One PCM protects from “cold”, the other from “heat”.
Example: Temperature Range of 2°C to 8°C• Use a liquid state 5°C PCM in combination with a solid state 0°C PCM.• The solid PCM melts transferring its energy to the liquid PCM which
freezes and transfers the 5°C temperatures to the payload.
30 www.cryopak.com
Experiment: Combination of 5°C PCM and 0°C PCM
Test Set-Up• EPS Insulated package with a water bottle as the payload.
• Payload surrounded with liquid state 5°C PCM (Phase 5) conditioned to 7°C.
• 5°C PCM surrounded by solid state 0°C PCM (Water Gel) conditioned to -20°C.
• Thermocouple recorded payload temperature.
Questions• Is the payload maintained between 2°C and 8°C?
31 www.cryopak.com
Results for Combination Experiment
Combination of 5°C PCM and 0°C PCM
0
5
10
15
20
25
30
35
40
0 6 12 18 24 30 36 42 48
Time(h)
Tem
per
atu
re(°
C)
Ambient Payload
32 www.cryopak.com
Package Design Case Studies
The examples that follow showcase the various uses of PCM’s discussed in the previous slides.• Dry Ice packages• Combination PCM packages• Packages designed for various temperature control
ranges and products.
33 www.cryopak.com
Temperature Range: Below –20°C (Dry Ice)
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
0 5 10 15 20 25 30 35 40 45 50
Time (h)
Tem
per
atu
re (
°C)
T/C 101 T/C 102 T/C 103 T/C 104 T/C 105 Ambient1 Ambient2
EPS Lid
EPS Collar with cut out for monitor
EPS Product Housing
Outer EPS Trough Housing
Lower EPS Collar
EPS Bottom
Outer shipper with EPS
34 www.cryopak.com
Temperature Range: –40°C to –20°CEPS Lid
Corrugate Divider
-20°C PCM
Dry Ice
-20°C PCM
Outer shipper with EPS
35 www.cryopak.com
Temperature Range: 2°C to 8°CEPS Lid
Refrigerated Water Gels
Frozen Water Gels
Payload Carton
Outer shipper with EPS
Frozen Water Gels
0
5
10
15
20
25
30
35
40
45
0 8 16 24 32 40 48
Time(h)
Tem
pera
ture
(°C
)
Dtmp-1-Ambient Dtmp-4-Product Dtmp-8-Product
36 www.cryopak.com
Temperature Range: 2°C to 8°C
EPS Lid
Water Gels
5°C PCM
Outer shipper with dual chamber EPS walls
0
5
10
15
20
25
30
35
40
0 6 12 18 24 30 36 42 48
Time (h)
Tem
per
atu
re (
°C)
T/C 6 10 T/C 6 11 T/C 6 12 T/C 6 18 Ambient T/C 6 19 Ambient High Low
37 www.cryopak.com
Temperature Range: 15°C to 30°C
EPS Lid
22°C PCM
Outer shipper with EPS
22°C PCM
Payload
-15
-10
-5
0
5
10
15
20
25
30
0 6 12 18 24 30 36 42 48
TIME(H)
TE
MP
ER
AT
UR
E(C
)
Dtmp-1-Ambient Dtmp-2-BOX 1 Dtmp-4-BOX 2 Dtmp-5-BOX 3
38 www.cryopak.com
Temperature Range: Below 37°C
EPS Lid
Thermos Lid
27°C PCM Vial Holder
Thermos
Outer shipper with EPS
0
5
10
15
20
25
30
35
40
45
50
0 4 8 12 16 20 24 28 32 36 40 44 48
Time(H)
Te
mp
era
ture
(C)
Chamber Ambient Data Logger High Limit
39 www.cryopak.com
Questions?
40 www.cryopak.com
Thank you!Anthony Alleva
Technical Services Manager
TCP Reliable, Inc.551 Raritan Center Parkway
Edison, NJ 08837
Tel: 732-346-9200 x 107
Email: [email protected]
Credit to: Jason HeberleProject Manager
DDL, West
www.cryopak.com
Use of Engineered Phase Change Materials in Cold Chain Packaging Design
Presented By:Anthony Alleva
Technical Services Manager, TCP Reliable, Inc.
Leveraging New Refrigerant Technologies