Level Transmitter / Controller / Indicator 2...Shuttle® Level Transmitter Shuttle® Level...
Transcript of Level Transmitter / Controller / Indicator 2...Shuttle® Level Transmitter Shuttle® Level...
Data Sheet
Asourproductsarecontinuouslyimproved,wereservetheright tomakeanychangeinthestatedspecificationsanddimensionswithoutpriornotice.US2.1Shuttle0708
2.1 Level Transmitter / Controller / Indicator
3-in-1 package that is simple to install and use.
With expanded ranges and improved chemical resistance.
Class 1, Division 1 Hazardous Areas
Approved SensorsNEW
Data Sheet
2
General
Features Shuttle®isdesignedtomeasurewaterlevelsaswellasotherfluidsandaggressivemedia,wheretheultrasonicsensorisnotincontactwiththemedia.• Ultrasonicmeasuringsystemwith3
sensorsmeasuringrangesfromfrom0-4in.to80ft.
• Learning-functionallowstheShuttle®LevelTransmittertolearnhowthetankisarrangedwithpiping,pumpsandotheritemsthatmightinterferewiththemeasu-rement.Thesystemalsoignoresturbu-lenceandelectricalinterference,soevenaslowmovingmixercanpassthroughtheultrasonicbeamwithoutanyinfluenceonthemeasurement.
• 2outputrelaysforlevel/systemalarmoralternatingpumpcontrolwithdutyand
standbycycles.• 4-20mAoutputwithzeroandspan
adjustment.• Indicationofthestrengthoftheecho
signalwithabargraph.• Verynarrowultrasonicpulsesignal
concentratessignalstrengthforminimumsensitivitytofoamandsludgeonthesurfaceoftheliquid.
• EasytoreadLCD-displayforbothsetupandindication.Actuallevelisindicatedwithbothabargraphandwithdigitsinmillimeters,centimetres,metres,feetandinches.Thedigitalreadoutcanbechosenaseitherrelativelevelorabsolutelevel.
• 10-30VDCor115VACsupply.• FMapprovedsensorsforhazardousareas.
Shuttle®isanadvancedmicro-processorbasedultrasoniclevelmeterwithanintel-ligentandveryprecisemeasuringsystemutilizingthenewesthardwareandsoftwaretechnologies.Shuttle®providessimpleandlogicalopera-tion,usingadvancedtechnologyresultinginahighqualityproductatacompetitiveprice.
Shuttle®isfullyautomaticafterinitialsetup.9functionbuttonsbehindthefrontpanelareusedtoconfigure:• Unitselectionineitherfeet,inchesme-
tres,centimetresandmillimetres.• Adjustmentofzerolevelofthemeasure-
mentandselectionofrelativeorabsolutereference.
• ZeroandspanforthemA-output.• Functionforthetwo2outputrelays-off,
levelalarm,systemalarmorpumpcontrolwithalternation.
• Learningfunction,sothelevelmeterrecognizeshowthewetwellisarrangedwithpumps,pipingandotherelementssothemeasurementwillnotbeaffectedbyfalseechos.
Operation
Shuttle®isequippedwith2outputrelayswhichcanbeconfiguredforlevelorpumpcontrol,systemalarmorlevelalarm.TherelayfunctioncanbesettoeitherNOorNC
Control functions functionwithanoptionaldelayfunction.Therelayscanbeusedforstartandstopofpumpswithalternation.
Shuttle® Level Transmitter / Controller / Indicator
Data Sheet
3
Application Shuttle®iswellsuitedforanyultrasoniclevelmeasurement.Theleveltransmittermayalsobeusedformeasuringandcontroloflevelsintankswithcontaminatedand/oraggressivemedia.Shuttle®has4-20mAoutputincreasingordecreasingwiththelevel,wherebothzerolevelandspancanbeadjustedforthewholerangeofthesensor.
Specifications
Electrical connections
Ultrasonic Sensor
Shuttle® Level Transmitter / Controller / Indicator
Typicalapplicationsaremeasurementandcontrolin:- stormflowtanks- pumpstations- tanksinsewagetreatmentplants- tanksinwaterplants- tanksandvesselsinprocessand
foodindustries
Shuttle® Level Transmitter
Shuttle® Level Transmitter
Range: 0-35ft,0-45ft,0-75ft
Span: From0-4in.to0-75ft
Powersupply: 115VAC±10%10-30VDC
Consumption: Approx.2W
Temperature: -5to+150°F
Input: Fromultrasonicsensor
Accuracy: ±0.2%
Outputs: Analog:4-20mA,max.load500Ω.Digital:2xrelayswithprogrammableNO/NCfunction.Max.1Aresistiveload@50V.
Indication: LCDdisplaywith4digitsandsymbols.
Operation: Functionkeypadbehindfrontpanel.
Enclosure: NEMA4X
Approvals: CE:EN50081-1,EN50082-1UL:FileE194021
Data Sheet
4
Shuttle®Ultrasonic sensors
Shuttle® Ultrasonic Sensor 200570 / 200771
Range: 45ft.(fluids)15ft.(solids)
Frequency: 30kHz
Spread: 3°
Deadband: 14"
Temperature: -5to+150°F
Materials: PP,POM
Cable: Shielded,oilresistantPVCinsulation,length39ft.(Max.300ft.with690010cable.)
Enclosure: NEMA6P,watertight,withstandsmax.30ftsubmersion.
CE-approvals: EN50081-1,EN50082-1
Standard range version
Shuttle® Ultrasonic Sensor: 200640 / 200641
Range: 35ft.(fluids),15ft.(solids)
Frequency: 40kHz
Spread: 7°
Deadband: 14"
Temperature: -5to+150°F
Materials: PTB,GlassreinforcedEpoxy
Cable200640:Cable200641:
Shielded,oilresistantPVCinsulation,length39ft.Shielded,oilresistantPVCinsulation,length164ft.(Max.300ft.with690010cable.)
Enclosure: NEMA6P,watertight,withstandsmax.30ftsubmersion.
CE-approvals: EN50081-1,EN50082-1
Ex-approvals: FMClass1,Div.1,GroupsA-G
Standard rangeversion
Extended range version
Shuttle® Ultrasonic Sensor: 200630 / 200631
Range: 80ft.(fluids),30ft.(solids)
Frequency: 30kHz
Spread: 6°
Deadband: 32"
Temperature: -5to+150°F
Materials: PTB,GlassreinforcedEpoxy
Cable200630:Cable200631:
Shielded,oilresistantPVCinsulation,length39ft.Shielded,oilresistantPVCinsulation,length164ft.(Max.300ft.with690010cable.)
Enclosure: NEMA6P,watertight,withstandsmax.30ftsubmersion.
CE-approvals: EN50081-1,EN50082-1
Ex-approvals: FMClass1,Div.1,GroupsA-G
Shuttle® Ultrasonic Sensor: 200660
Range: 30ft.(fluids),15ft.(solids)
Frequency: 50kHz
Spread: 6°
Deadband: 14"
Temperature: -5to+150°F
Materials: PP,PVDF
Cable: Shielded,oilresistantPVCinsulation,length39ft.(Max.300ft.with690010cable.)
Enclosure: NEMA6P,watertight,withstandsmax.30ft.submersion.
CE-approvals: EN50081-1,EN50082-1
Chemical resistent version
Data Sheet
5
Shuttle®Ultrasonic sensors
9090
6060
3030
0
-40
-30
-20
-10dB
Ultrasonic sensor type 200570 / 200771
Frequency: 30KHz
Range: Upto45ft.influidsand15ft.insolids.
Directivity: Seefigurebelow.
Standard range version
9090
6060
3030
0
-40
-30
-20
-10dB
Ultrasonic sensor type 200640 / 200641
Frequency: 40KHz
Range: Upto35ft.influidsand15ft.insolids.
Directivity: Seefigurebelow.
Standard range version
9090
6060
3030
0
-40
-30
-20
-10dB
Ultrasonic sensor type 200630 / 200631
Frequency: 30KHz
Range: Upto80ft.influidsand30ft.insolids.
Directivity: Seefigurebelow.
Extended range version
Ultrasonic sensor type 200660
Frequency: 50KHz
Range: Upto30ft.influidsand15ft.insolids.
Directivity: Seefigurebelow.
Chemical resistent version
Data Sheet Shuttle® Level Transmitter / Controller / Indicator
Dimensions
Universal bracket
Sensor bracket, standardSensor bracket, short
Shuttle® Level Transmitter
Ultrasonic sensor200570 / 200660 /
200571
Ultrasonic sensor200640 / 200630 / 200641 / 200631
Order numbers Shuttle® Level Transmitter complete with Ultrasonic Sensor
201209 Shuttle®LevelTransmitterwithoutsensor,powersupply115/230VACor10-30VDC
201214 Shuttle®LevelTransmittercompletewithUltrasonicSensor200570and39ft.ofcable,powersupply115/230VACor10-30VDC
201224 Shuttle®LevelTransmittercompletewithUltrasonicSensor200630and39ft.ofcable,powersupply115/230VACor10-30VDC
201234 Shuttle®LevelTransmittercompletewithUltrasonicSensor200640and39ft.ofcable,powersupply115/230VACor10-30VDC
201244 Shuttle®LevelTransmitter,completewithShuttle®UltrasonicSensor200660and39ft.ofcable,powersupply115/230VACor10-30VDC
Accessories
200205 Universalbracket
200219 ShortSensorbracketforUltrasonicSensor
200220 StandardSensorbracketforUltrasonicSensor
200590 ConnectionboxforUltrasonicSensorcable
690010 AdditionalcableforUltrasonicSensor.Canbeextendedto300ft.,specifylength
200570 UltrasonicSensor,30kHz,39ft.ofcable,range:45ft.influids,15ft.insolids
200571 UltrasonicSensor,30kHz,150ft.ofcable,range:45ft.influids,15ft.insolids
200630 UltrasonicSensor,30kHz,39ft.ofcable,range:75ft.influids,30ft.insolids
200631 UltrasonicSensor,30kHz,150ft.ofcable,range:75ft.influids,30ft.insolids
200640 UltrasonicSensor,40kHz,39ft.ofcable,range:35ft.influids,15ft.insolids
200641 UltrasonicSensor,40kHz,150ft.ofcable,range:35ft.influids,15ft.insolids
200660 Ultrasonicsensor,50kHz,39ft.ofcable,range:30ft.influids,15ft.insolids
840010 Shuttle®CommunicationSoftwareforsettingsincl.InterfaceandRS232cable
840011 Shuttle®CommunicationSoftwareforsettingsandFirmware,incl.InterfaceandRS232cable