Level Measuring Instruments

12
Level Measuring Instruments Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications engineering Engineering systems & solutions © KROHNE 09/2001 7.02316.22.00 GR/PRINTO

Transcript of Level Measuring Instruments

Page 1: Level Measuring Instruments

Level MeasuringInstruments

Variable area flowmeters

Vortex flowmeters

Flow controllers

Electromagnetic flowmeters

Ultrasonic flowmeters

Mass flowmeters

Level measuring instruments

Communications engineering

Engineering systems & solutions

© KROHNE 09/2001 7.02316.22.00

GR/PRINTO

Page 2: Level Measuring Instruments

2

KROHNELevel MeasuringInstruments

KROHNE level production and marketingfacilities are located in Germany, France,England, the United States and other count-ries for a variety of reasons. Primarily to gainan international edge in applications.

We make our products globally applicable.

The latest in quality assurance and a parti-cularly intense KANBAN production help usto drastically improve delivery speed downto a few days for regular products and only afew weeks for specials.

The KROHNE Strategy

KROHNE is present in almost every plantand process in the world. A global player, wereact quickly to your customer’s demands,whatever they ask, whenever they ask.

We are members of all important industrialassociations to ensure we anticipate theindustrial trends of the future, and then setthe benchmarks that others follow.

At KROHNE, we pride ourselves on beingeasy to do business with. Our key objectivesare to offer the best products for your applications, and to ensure that co-operationwith us is as easy as possible, we supportall our sales activities with extensive pre-and post-sales consultancy and technicalassistance.

KROHNE – easy to work with.

We offer a comprehensive and versatile range of level gauges and levelswitches for level measurement.

KROHNE level products are found in all industries, in all types of storagetanks and silos, in hazardous areas, onshore and offshore as well as ontanker ships, road and rail transporters.

Implementation of various measuring principles, advanced technologyand stringent quality control procedures have produced measuringinstruments which guarantee high accuracy even under extreme operating conditions. Applications extend from liquid sulphur at 284°F(140°C) to the storage of liquefied gases; from tanks on oceangoingships to storage tanks in nuclear power stations.

Our experience in the industry enables us to adapt to a wide variety ofapplications in every industry. You can count on KROHNE for accurate,reliable measurements, even under the most difficult conditions, all atan affordable price.

KROHNE level measuring instruments meet the requirements of EMCguidelines and CE directives. All factories are certified to ISO 9001.

Official approvals are available for many of our devices as follows:

� FM and ’Ex’ certificates of conformity

� Approval as part of an overfill protection system

� Approvals in conformity with the German pressure vessel code andvarious other international approvals

Our devices can be fitted with a choice of user-specific processconnections. Various interfaces such as RS 485, Modbus, PROFIBUS-PA, Foundation Fieldbus and HART® are available for intelligent datacommunication.

Page 3: Level Measuring Instruments

Contents

Selection Matrix .............................................................................. 4–5Product Overview .......................................................................... 6–12

Vibration switchesLS 300-Ex/F, LS 3000 ................................................................ 13–24

Capacitive switchesLS 210 / LS 220 ....................................................................... 25–32

Buoyancy switchesBM 34 ....................................................................................... 33–40BW 17 ....................................................................................... 41–48

Ultrasonic sludge level switchUSS 11 ...................................................................................... 49–52

Level -RadarBM 700, BM 70 A, BM 70 P ....................................................... 53–78BM 702 ..................................................................................... 79–88

Level SonicBM 90 ....................................................................................... 89–96

Level TDRBM 100 ................................................................................... 97–106BM 102 ................................................................................. 107–116

Buoyancy levelBM 24 / BM 51 ..................................................................... 117–126LT 100 ................................................................................... 127–136BM 26 ................................................................................... 137–150BW 25 ................................................................................... 151–158

Ultrasonic sludge level meterUSP 10 .................................................................................. 159–163

Pro

duct

Ove

rvie

wU

ltra

soni

cB

uoy

ancy

Cap

acit

ance

Ult

raso

nic

Rad

arU

ltra

soni

cB

uoya

ncy

TDR

Cont

inuous,

non-

cont

act

Sw

itch

es

Vib

rati

on

Cont

inuous,

cont

act

3Level Catalogue

Page 4: Level Measuring Instruments

Switch

4 Level Catalogue

LS 210, LS 220RF (capacitance) level switches for liquids,granules and interfaceTank pressure up to 25 bar / 362 psig

NEW

Liquid Interface Powder/ Interfaceliquid Granulates sludge

Vibration ✔Max. length 6 m (20 ft)Max. pressure 40 bar (580 psig)Product temp. –40 … +150°C

(–40 … +302°F)

Capacitance ✔ ✔ ✔Max. length 35 m (115 ft)Max. pressure 25 bar (362 psig)Product temp. –40 … +125°C

(–40 … +257°F)

Buoyancy ✔ ✔Max. length 24 m (79 ft)Max. pressure 40 bar (580 psig)Product temp. –200 … +400°C

(–328 … +752°F)

Ultrasonic ✔Max. length 10 m (33 ft)Max. pressure 1 bar (14.5 psig)Product temp. –20 … +80°C

(–4 … +176°F)

cont

act

Page 5: Level Measuring Instruments

5

Pro

duct

Ove

rvie

wU

ltra

soni

cB

uoy

ancy

Cap

acit

ance

Ult

raso

nic

Rad

arU

ltra

soni

cB

uoya

ncy

TDR

Cont

inuous,

non-

cont

act

Sw

itch

es

Vib

rati

on

Cont

inuous,

cont

act

Level Catalogue

Continuous measurement

BM 702 Level-RadarThe first and only FMCWradar level gauge with 2-wire technology nowwith Ex-approval

BM 102 MICROFLEXThe universal 2-wirelevel gauge for liquidsand solids operating onthe TDR principle nowwith Ex-approval

NEW

contact

non-co

ntact

mechanic

ele

ctronic

Liquid Interface Interface Powder/ Pasteliquid sludge Granulates

✔ ✔ ✔ RadarMax. length 100 m (330 ft)Max. pressure 400 bar (5800 psig)Flange temp. –60 … +250°C

(–76 … +482°F)

✔ ✔ UltrasonicMax. length 15 m (50 ft)Max. pressure 1 bar (14.5 psig)Product temp. –40 … +90°C

(–40 … +194°F)

✔ ✔ ✔ ✔ TDRMax. length 60 m (200 ft)Max. pressure 100 bar (1450 psig)Product temp. –200 … +650°C

(–328 … +1202°F)

✔ ✔ BuoyancyMax. length 24 m (80 ft)Max. pressure 40 bar (580 psig)Product temp. –200 … +400°C

(–328 … +752°F)

✔ UltrasonicMax. length 10 m (33 ft)Max. pressure 1 bar (14.5 psig)Product temp. –20 … +80°C

(–4 … +176°F)

Page 6: Level Measuring Instruments

Level Catalogue

Product Overview

6

LS 300-Ex/F, LS 3000 LS 210 / LS 220

LS 300-Ex/F

LS 3000

LS 210

LS 220

BM 34

Product Liquids, solids Liquids, solids, interface LiquidsMax. length 6 m (20 ft) 35 m (115 ft) 6 m (20 ft)Repeatability ± 1 mm (0.04”) ± 2 mm (0.08”) ± 3 mm (0.12”)Operating dataPressure ≤ 25 bar (362 psig) LS 210: ≤ 10 bar (145 psig) ≤ 40 bar (580 psig)

LS 220: ≤ 25 bar (362 psig)Temperature LS 300-Ex/F –40 ... +135°C LS 210: –40 ... +100°C –200 ... +200°C

(–40 ... +275°F) LS 210: (–40 ... +212°F) (–328 ... +392°F)LS 3000 –40 ... +150°C LS 220: –40 ... +125°C

(–40 ... +302°F) LS 210: (–40 ... +257°F)Density (ρ) LS 300-Ex/FViscosity (η) ρ ≥0.6 kg/l (37.5 lb/ft3) εr ≥ 1.5 ρ ≥ 0.4 kg/l (25 lb/ft3)Dielectric constant (εr) η ≤ 10 000 mPa·s η ≤ 5 000 mPa·s

LS 3000ρ ≥ 0.4 kg/l (25 lb/ft3)η ≤ 10 000 mPa·s

Process connection G1A, Flange ≥ DN 50 (2”) ≥ 3/4” NPT, Flange ≥ DN 25 (1”)Flanges ≥ DN 25 (1”)

Materials(Wetted parts) Stainless steel, PVDF, AISI 316 L, PPS Stainless steel, titanium,

Halar Hastelloy, PTFE/hard glass,PVC, PP, hard rubber

Local display ✔ – –Options/accessories Probe lengths up to Probe lengths up to Up to 6 limit switches

6 m (19.7 ft) 35 m (115 ft); probe protectionApprovals Ex-Zone 0, overfill protection Ex-Zone 0, 10 Ex-Zone 0, overfill protection

SwitchesVibration Capaticance Buoyancy

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

Page 7: Level Measuring Instruments

Pro

duct

Ove

rvie

wU

ltra

soni

cB

uoy

ancy

Cap

acit

ance

Ult

raso

nic

Rad

arU

ltra

soni

cB

uoya

ncy

TDR

Cont

inuous,

non-

cont

act

Sw

itch

es

Vib

rati

on

Cont

inuous,

cont

act

Level Catalogue 7

Product Overview

USS 11BW 17

Liquids Sludge Productnon applicable 10 m (33 ft) Max. lengthSwitching hysteresis 5–32 mm (0.2”–1.26”) Switching hysteresis 2 – 20% Repeatability

Operating data≤ 64 bar (928 psig) Atmospheric Pressure

≤ 300°C (572°F) -20 ... 80°C (-4 ... 176°F) Temperature

ρ ≥ 0.45 kg/l (28 lb/ft3) 0.5 – 8.0% dry matter Density (ρ)η ≤ 100 mPa·s Viscosity (η)

Dielectric constant (εr)

Flange ≥ DN 65 (21/2”) – Process connection

MaterialsStainless steel, PVDF, Titanium, PTFE (Wetted parts)PP, Halar

– – Local displayVarious level extensions Available with either 1 or 2 switching Options/accessoriesDifferent types of switches points (probes, control units)Ex-Zone 0, overfill protection – Approvals

SwitchesBuoyancy Ultrasonic

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

Page 8: Level Measuring Instruments

Product Overview

8 Level Catalogue

BM 700 / BM 70 A / BM 70 P

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

Product Liquids, pastes, slurries, particulate materials liquified gases Liquids, pastes, slurries

Max. length 100 m (330 ft) 20 m (66 ft)Repeatability ± 0.3% – 0.1% ± 1 cm or 0.2%

Operating dataPressure ≤ 400 bar (5800 psig) ≤ 400 bar (5800 psig)Temperature –60 ... +250°C (–4 ... +482°F) flange temp. –60 ... +250°C

(–76 ... +482°F)flange temp.

Density (ρ) – –Viscosity (η)Dielectric constant (εr)Process connection Flange DN 50 – DN 200 (2’’ – 8’’) / G 11/2” Flange DN 50–DN 200,

2’’– 8’’/G 11/2”Materials(Wetted parts) Stainless steel, Hastelloy C4 or B2, Stainless steel, Hastelloy C4

tantalum, titanium, PTFE or B2, tantalum, titanium, PTFE

Local display ✔ ✔

Options/accessories Ex-e/Ex-i current output HART® – Relay output, digital inputdigital output RS 485, PROFIBUS-PA

Approvals Ex-Zone 0, 1 Ex-Zone 0, 1

Continuous, non-contactRadar

BM 702

Page 9: Level Measuring Instruments

9

Product Overview

Pro

duct

Ove

rvie

wU

ltra

soni

cB

uoy

ancy

Cap

acit

ance

Ult

raso

nic

Rad

arU

ltra

soni

cB

uoya

ncy

TDR

Cont

inuous,

non-

cont

act

Sw

itch

es

Vib

rati

on

Cont

inuous,

cont

act

Level Catalogue

BM 90

Liquids, pastes and slurries Liquids, pulverized and Liquids, solids Productgranulated materials and powders

15 m (50 ft) 60 m (200 ft) 24 m (79 ft) Max. length± 0.25% of measured distance Liquids: ± 5 mm (0.2”) Liquids: ± 5 mm (0.2”) Repeatability

+3% of the measured value Powders: ± 20 mm (0.75”) Powders: ± 20 mm (0.79”)

Operating dataAtmospheric ≤ 100 bar (1450 psig) ≤ 40 bar (580 psig) Pressure-40 ... +90°C (-40 ... +194°F) -200 ... +650°C -200 ... +650°C Temperature

(-328 ... +1202°F) (-328 ... +1202°F)

– – – Density (ρ)Viscosity (η)Dielectric constant (εr)

Flange ≥ DN 80, M 20 x 1.5 mm Flange ≥ DN 50 (2”), G 1A G 1”, Flange ≥ DN 50 Process connection

MaterialsPVC, Urethane, PTFE Stainless steel, PTFE, Stainless steel, PTFE, (Wetted parts)

Ceramic, Hastelloy, tantalum, Hastelloy, tantalum, titaniumtitanium

✔ ✔ – Local displaycurrent output EExe current output HART® EEx ia HART® Options/accessories5 relays EExi current output HART® loop powered

2 outputs EEx d pendingdigital output RS 485

Ex-Zone 1, 2 Ex-Zone 0, 10 Ex-Zone 0, 10 Approvals

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

Continuous, contactUltrasonic TDR

BM 102BM 100 A

Page 10: Level Measuring Instruments

Product Overview

10 Level Catalogue

BM 24 BM 51 LT 100

BuoyancyContinuous, contact

Product Liquids Liquids LiquidsMax. length 24 m (80 ft) 6 m (20 ft) 6 m (20 ft)Repeatability ± 2 mm (0.08”) ± 3 mm (0.12”) ± 5 mm (0.2”)

of measured value of measured valueOperating dataPressure ≤ 40 bar (580 psig) ≤ 25 bar (363 psig) ≤ 40 bar (580 psig)

Temperature –200 ... +400°C –200 ... +400°C –40 ... +130°C(–328 ... +752°F) (–328 ... +752°F) (–40 ... +266°F)

Density (ρ) ρ ≥ 0.4 kg/l (25 lb/ft3) ρ ≥ 0.4 kg/l (25 lb/ft3) ρ ≥ 0.4 kg/l (25 lb/ft3)Viscosity (η) η ≤ 5 000 mPa·s η ≤ 5 000 mPa·s η ≤ 5 000 mPa·sDielectric constant (εr)Process connection Flange ≥ DN 50 (2”) Flange ≥ DN 50 (2”) G 1“, Flange ≥ DN 50 (2”)Materials(Wetted parts) Stainless steel, Stainless steel, Stainless steel, titanium,

titanium, Hastelloy, PTFE, PVC, PP, PVC, PP, PVDF, PTFEPTFE, PVC, PP, PVDF, hard glass hard glass

Local display ✔ ✔ –Options/accessories Up to 4 limit switches, Up to 4 limit switches, current output

electric or pneumatic data electric or pneumatic data data transmissiontransmission, heating system transmission up to 2000 m (6500 ft)

Approvals Ex-Zone 0, overfill protection Ex-Zone 0, overfill protection Ex-Zone 1

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

Page 11: Level Measuring Instruments

11

Product Overview

Level Catalogue

Liquids Liquids Sludge Product9 m (30 ft) 6 m (20 ft) 10 m (33 ft) Max. length± 5mm (0.2”) ± 1.5% of full scale range Switching hysteresis 2 – 20% Repeatabilityof measured value

Operating data≤ 40 bar (580 psig) ≤ 40 bar (580 psig) atmospheric Pressureoptional 100 bar (1450 psig) optional 700 bar (10000 psig)-200 ... 400°C (-328 ... 752°F) -60 ... 400°C (-76 ... 752°F) -20 ... 80°C (-4 ... 176°F) Temperature

ρ ≥ 0.5 kg/l (31 lb/ft3) ρ ≥ 0.4 kg/l (25 lb/ft3) 0.3 – 10% dry matter Density (ρ)η ≤ 5 000 mPa·s Viscosity (η)

Dielectric constant (εr)Flange DN 15–DN 50 (1/2”–2”) Flange ≥ DN 40 (11/2”) – Process connection

MaterialsStainless steel, titanium, Stainless steel, titanium Titanium, PTFE (Wetted parts)Hastelloy, PTFE, PVC,PVDF/hard glass✔ ✔ ✔ Local displayLimit switches, Up to 2 limit switches, Signal output for sludge Options/accessorieselectric data transmission, reference vessel for lateral concentration, max. 2 inductiveheating system installation ekectric level contacts, variable floow-up

transmission speed of probeEx-Zone 0, overfill protection Ex-Zone 0 – Approvals

Detailed technical data and descriptions can be found in the data sheets for the appropriate instrument.

BM 26 BW 25 USP 10

Continuous, contactBuoyancy Ultrasonic

Pro

duct

Ove

rvie

wU

ltra

soni

cB

uoy

ancy

Cap

acit

ance

Ult

raso

nic

Rad

arU

ltra

soni

cB

uoya

ncy

TDR

Cont

inuous,

non-

cont

act

Sw

itch

es

Vib

rati

on

Cont

inuous,

cont

act

Page 12: Level Measuring Instruments

12

Notes