Level 1 Report
Transcript of Level 1 Report
Hotel Hallway Analysis
Date: 08 / 20 / 2012Operator: Weber Analytics
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Table of contents
Hotel Hallway AnalysisProject Cover 1Table of contents 2ZUMTOBEL STAFF LIGHTING S5D7108 7108RC S5; S5D; SPEC-5; FORMED STEE...
Luminaire Data Sheet 3OCL ORIGINAL CAST LIGHTING INC - ST. LOUIS, MO IEM-ICS4-10-7-X-2BP-...
Luminaire Data Sheet 4Typical of Four (4) Fixtures in Front of Guest Doors
Summary 53D Rendering 6False Color Rendering 7Room Surfaces
Hallway @ 36"Isolines (E, Perpendicular) 8
Guest Entry Detail @ 36"Isolines (E, Perpendicular) 9
FloorIsolines (E) 10
w w w . w e b e r a n a l y t i c s . c o m Page 2
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
ZUMTOBEL STAFF LIGHTING S5D7108 7108RC S5; S5D; SPEC-5; FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM NO ENCLOSURE. HORIZONTAL LAMP
ORIENTATION. / Luminaire Data Sheet
See our luminaire catalog for an image of the luminaire.
Luminous emittance 1:
200
300
500
cd/klm 63%C0 - C180 C90 - C270
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
Luminaire classification according to CIE: 100CIE flux code: 84 100 100 100 64
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
w w w . w e b e r a n a l y t i c s . c o m Page 3
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
OCL ORIGINAL CAST LIGHTING INC - ST. LOUIS, MO IEM-ICS4-10-7-X-2BP-1 WATTS=51 REFL=87% UNIVERSAL BALLAST #C2642UNVSE & BODINE EMERGENCY
#B94 / Luminaire Data Sheet
See our luminaire catalog for an image of the luminaire.
Luminous emittance 1:
30
45
60
75
cd/klm 30%C0 - C180 C90 - C270
0° 15° 30° 45°
60°
75°
90°
105°
120°
135°150°165°180°165°150°135°
120°
105°
90°
75°
60°
45° 30° 15° 0°
Luminaire classification according to CIE: 54CIE flux code: 15 40 69 54 30
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
w w w . w e b e r a n a l y t i c s . c o m Page 4
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / Summary
1020 2025 25 40
70.00 ft0.00
6.00 ft
0.002.004.00
Height of Room: 9.500 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:153
Surface [%] Eav [fc] Emin [fc] Emax [fc] u0
Workplane / 25 4.94 49 0.198Floor 10 18 3.14 32 0.177Ceilings (11) 75 4.07 1.98 7.12 /Walls (4) 40 9.02 1.59 139 /
Workplane:Height: 2.500 ftGrid: 128 x 8 Points Boundary Zone: 2.001 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.383, Ceiling / Working Plane: 0.163.
Luminaire Parts List
Specific connected load: 1.09 W/sq ft = 0.44 W/sq ft/10 fc (Ground area: 420.01 sq ft)
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
1 4
OCL ORIGINAL CAST LIGHTING INC - ST. LOUIS, MO IEM-ICS4-10-7-X-2BP-1 WATTS=51 REFL=87% UNIVERSAL BALLAST #C2642UNVSE & BODINE EMERGENCY #B94 (1.000)
1094 3600 51.0
2 14
ZUMTOBEL STAFF LIGHTING S5D4312S1 4311RC S5; S5D; SPEC-5; FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM REFLECTOR, NO ENCLOSURE. VERTICAL LAMP ORIENTATION. (1.800)
564 1250 18.0
Total: 12269 Total: 31900 456.0
w w w . w e b e r a n a l y t i c s . c o m Page 5
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / 3D Rendering
w w w . w e b e r a n a l y t i c s . c o m Page 6
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / False Color Rendering
0 1.00 3.00 5.00 10.00 15.00 20.00 25.00 50.00 fc
w w w . w e b e r a n a l y t i c s . c o m Page 7
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / Hallway @ 36" / Isolines (E, Perpendicular)
5 510 10 10
101015 15 15
20 2020 20 20 2025
2525
25
30 3030
30 3035
3535 35 35
4040
40 40 40
4040
70.00 ft0.00
6.00 ft
0.00
Values in Footcandles, Scale 1 : 153Position of surface in room:Marked point:(0.000 ft, 0.000 ft, 3.000 ft)
Grid: 128 x 32 Points
Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax24 2.70 66 0.114 0.041
w w w . w e b e r a n a l y t i c s . c o m Page 8
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / Guest Entry Detail @ 36" / Isolines (E, Perpendicular)
2525
30
30
30
30
30
30
30
35
35
3535
35
35
35
35
35
35
35
40
40
40 40
40
40
40
4040
40
40
4545 45
4545
4545
9.00 ft0.00
6.00 ft
0.00
Values in Footcandles, Scale 1 : 20Position of surface in room:Marked point:(35.500 ft, 0.000 ft, 3.000 ft)
Grid: 32 x 32 Points
Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax34 20 46 0.598 0.446
w w w . w e b e r a n a l y t i c s . c o m Page 9
Hotel Hallway Analysis08 / 20 / 2012
Weber Analytics432 North Main Street, Suite 200Blacksburg, VA 24060
Operator Weber AnalyticsTelephone 540.553.6171
Faxe-Mail [email protected]
Typical of Four (4) Fixtures in Front of Guest Doors / Floor / Isolines (E)
5 10 10 101515
1515 15
2020 20
2020
202025 25 25 25
252525
25
2530 30
30
70.00 ft0.00
6.00 ft
0.00
Values in Footcandles, Scale 1 : 153Position of surface in room:Marked point:(0.000 ft, 0.000 ft, 0.000 ft)
Grid: 128 x 32 Points
Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax18 3.14 32 0.177 0.097
w w w . w e b e r a n a l y t i c s . c o m Page 10