Levapor Bio Film Technologies and Bio Consulting GmbH

25

description

High Performance Bio Carrier For the Treatment of High Strength Industrial And Municipal Effluents

Transcript of Levapor Bio Film Technologies and Bio Consulting GmbH

Page 1: Levapor Bio Film Technologies and Bio Consulting GmbH
Page 2: Levapor Bio Film Technologies and Bio Consulting GmbH

About us

• We are Levapor Biofilm Technologies and Bio Consulting , GmbH.

• A specialized company providing innovative solutions for the treatment of wastewater and polluted air

• A team with more than 40 years of experience in research and development of fixed film based technologies for industrial and difficult to treat wastewater and polluted air

Page 3: Levapor Bio Film Technologies and Bio Consulting GmbH

What We do • Problem analysis for the treatment of high strength

industrial and municipal wastewater treatment • Define treatment goals and conceptual process

design • Development of optimal process and parameters • Manufacturing of high performance tailor made bio

carriers for the application • Process Start up

Page 4: Levapor Bio Film Technologies and Bio Consulting GmbH

Our Specialization • Anaerobic pre treatment of complex, persistent

industrial wastewater • Nitrification – De nitrification of effluents containing

inhibitory substances• Biological waste gas treatment using BTF(Bio

Trickling Filters) • Biofilm Reactor IFAS/MBBR for industrial and

municipal wastewater • Production and delivery of High Performance Bio

Carriers

Page 5: Levapor Bio Film Technologies and Bio Consulting GmbH

Our Achievements • First full scale nitrification/denitrification plant for

ammonia rich effluents (1978) • Development of high performance bio carriers (1983) • Degradation of toxic effluents by anaerobic bio film

technologies (1985) • Design of full scale process for the anaerobic-aerobic

degradation of toxic effluents (1998) • Indoor bio treatment of polluted air for a ware house

of waste plastic (2002)

Page 6: Levapor Bio Film Technologies and Bio Consulting GmbH

Industries We serve

• Chemicals and Pharmaceuticals• Petrochemicals and Refineries • Pulp and Paper • Coal Conversion : coke plant, coal gasification,

pyrolysis• Textile finishing and Leather manufacturers • Municipal Wastewater Treatment • Special effluents like land fill leachate and sludge

processing unit

Page 7: Levapor Bio Film Technologies and Bio Consulting GmbH

Our Clientele• SAPPI , Germany : 20 MLD anaerobic-aerobic treatment

plant for treatment of high strength pulp and paper mill effluent

• City of Ningan, China : 22 MLD Municipal wastewater treatment plant for COD removal and nitrification

• City of Helsinki : Upgradation of existing municipal wastewater treatment plant

• Ludan Engineering, Middle East : Bio treatment of fine chemicals wastewater

• KERRY Intra, India : Bio treatment of container wash water

Page 8: Levapor Bio Film Technologies and Bio Consulting GmbH

Our Technology

• LEVAPOR Bio Carrier • First synthesized Bio Carrier • Porous, Flexible, Durable PU foam

impregnated with surface active pigments with high surface area

• Due to variability of foam and pigment type and their ratios, tailor made carriers can be produced with varying properties

Page 9: Levapor Bio Film Technologies and Bio Consulting GmbH

Our Technology

Page 10: Levapor Bio Film Technologies and Bio Consulting GmbH

Unique Properties

PROPERTIES • High Adsorbing Surface

• High Porosity

• Fast wetting and water binding

• High surface Area • Higher fluidization ability

ATTRIBUTES• Adsorption of inhibitory

substances and fast colonization • Protection of biomass against

shear, anoxic zone formation • Homogenization of media and

maintenance of bio activity • Lower Degree of Filling (12-

15%)• Less Power consumption

Page 11: Levapor Bio Film Technologies and Bio Consulting GmbH

Advantages • Reversible adsorption of inhibitory substances and slowly

bio degradable pollutants • Short process start up and higher performance compared

to suspended mass based systems (100 to 300%)• Colonization of carrier by more active bio mass and

simultaneous nitrification-de nitrification • Higher process stability and lower sludge yield • Lower degree of filling (12 to 15% compared to 40-65%

for plastic based media) • Remarkable lower power consumption compared to

conventional MBBRs

Page 12: Levapor Bio Film Technologies and Bio Consulting GmbH

Applications• Up gradation/expansion of existing plants • Anaerobic-Aerobic treatment of high strength , slowly

bio degradable pollutants • Nitrification- de nitrification of effluents containing high

ammonia concentrations• Biological Treatment of Polluted air/gas (BTF)• Biofilm reactor MBBR/IFAS for the treatment of

industrial and municipal wastewater • Treatment of hyper saline effluents containing solvents • Treatment of land fill leachate and groundwater

containing PAHs.

Page 13: Levapor Bio Film Technologies and Bio Consulting GmbH

Case Studies

• City of NINGAN Wastewater treatment Plant • Heilongjiang Province , China• 4,40,000 Population • Very Cold climate during winter • Difficulty in maintaining nitrification during

winter • Stricter Legal discharge limits

Page 14: Levapor Bio Film Technologies and Bio Consulting GmbH

NINGAN,WWTP

• Solution :• 3200 m3 of aeration tank

volume • 480m3 of Levapor Bio

carrier• 15% Filling • 20 X 20 X 7 mm size

Page 15: Levapor Bio Film Technologies and Bio Consulting GmbH

NINGAN, WWTP

• Legend Dimension Value

Volume of Reactor M3 3200 (4 X 800)

Volume of Levapor M3 480m3

HRT Hours 3.5-3.8

2012 October Nov. Dec.

COD in Mg/lit 294 295 302

COD out Mg/lit 33.7 35.8 37.7

BOD out Mg/lit 11.9 11.9 12.9

TKN in Mg/lit 28.8 35.5 23.2

NH4.N out Mg/lit 2.0 3.3 3.34

NO3.N out Mg/lit 12.5 14.8 11

Temperature Degree C 15.6 13.3 9.6

Page 16: Levapor Bio Film Technologies and Bio Consulting GmbH

NINGAN ,WWTP

Page 17: Levapor Bio Film Technologies and Bio Consulting GmbH

NINGAN,WWTP

Page 18: Levapor Bio Film Technologies and Bio Consulting GmbH

NINGAN,WWTP

• Benefits:• 88-90 % COD and 91-93% NH4.N reduction despite

decreasing temperature and shorter HRTs• Remarkable process stability against temp, COD, TKN

variations • Lower level of nitrate confirming denitrification • Lower capital and operational cost

Page 19: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY• SAPPI EFFLUENT TREATMENT PLANT:• South Africa Pulp and Paper Industry, Ehingen, Germany • Sulfite based pulp and paper industry• Application of Chlorine for bleaching • High Concentration of toxic, weakly bio degradable

chloro-organic compounds • Strong Stream : COD 45 t/d @ 10 MLD • Weak Stream : COD 2.45 t/d @ 3.5 MLD

Page 20: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY

Lab scale testing Anaerobic or Aerobic?• Aerobic treatment with

suspended bio mass • Only 40-45 % COD

elimination • Anaerobic-Aerobic

Treatment ? • Anaerobic reactors using

different bio carriers

Page 21: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY

• 1 :Levapor • 2: Activated Carbon • 3: Unmodified PU foam • 4: Suspended Bio mass

Page 22: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY• Solution :• Anaerobic Treatment Using Levapor Carriers • Reactor Size only 15000 m3 instead of 65000m3 with

suspended bio mass • 1500 m3 of Levapor media • 66-70% COD removal • Further 50% of COD removal in Aerobic Treatment • 50,000 m3 less volume

Page 23: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY

Startup: 1990, only 2 of 3 ANA-reactors were started with LEVAPOR in order to compare the effect of immobilisation. After few weeks a toxic shock has stopped the reactor without LEVAPOR Nowadays: ~ 85 % COD- removal , 4 – 6 t/d sludge, 14.000 m³/d biogas

Page 24: Levapor Bio Film Technologies and Bio Consulting GmbH

SAPPI,GERMANY

0

0,5

1

1,5

2

2,5

3

3,5

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

susp.biomass

May 90 June 90

immob. biomasskgCOD/m³ x day

Page 25: Levapor Bio Film Technologies and Bio Consulting GmbH

Thank You!!!!