LeoniLeoni Gigaline fiber optics cable data sheet

2
INDUSTRY GigaLine ® outdoor cable, central loose tube 2500N Fibre optic outdoor cable, single tube, longitudinally watertight, with corrugated steel tape armour Type KL-A-DQ(ZN)2Y(SR)2Y 1 x m G/E.. Construction: 1) Fibre: single mode fibre E9..10/125 µm multi mode fibre G50/125 µm multi mode fibre G62.5/125µm Colour code: fibres 1-12: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Fibres 13-24 with black ring sign: red, green, blue, yellow, white, grey, brown, violet, turquoise, nature, orange, pink 2) Core: gel-filled loose tube up to 12 fibres Ø 2.9mm, up to 24 fibres Ø 3.5mm 3) Strain-relief aramid yarns/glass rovings 4) Sheath: PE 5) Armour: sheath with corrugated steel tape 6) Sheath: PE, sunlight resistant Colour outer sheath: Jet black RAL-9005 Fibre quality: 0,36F3,5/0,22H18; E9..10 low OH, OS2 3.0B250/0.7F800-GBE500/1000; G62.5/125 OM1e 2,5B600/0,7F1200-GBE750/2000; G50/125 OM2e 2.5B1500/0.7F500-10GBE300; G50/125 OM3 bendable Printing Inkjet: LEONI GigaLine A-DQ(ZN)2Y(SR)2Y n x m $fibre type$ $~~$ $reel no.$ $ $meter mark$ Temperature range Transport and storage -25°C to +70°C During installation -5°C to +50°C After installation -25°C to +60°C Bending radius After installation: 15 x outer diameter During installation: 20 x outer diameter Longitudinal watertightness: IEC 60794-1-2 F5 Halogen acid gas emission: IEC 60754-1 Impact: IEC 60794-1-2 E4 Bending: IEC 60794-1-2 E11 Chemical continuance: Free of hazardous substances acc. to RoHS 2002/95/EG Temperature test: IEC 60794-1-2, method F1 Strain-relief elements: IEC 60794-1-2, method E1 Crush: IEC 60794-1-2, method E3 LEONI Kerpen GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154, Email [email protected], www.leoni-infrastructure-datacom.com Valid except for misprints and errors. Technical values subject to change (without notice). The original document is in German language. In case of doubt or conflict, the German language version will prevail.

description

Leoni Gigaline fiber optics cable data sheet

Transcript of LeoniLeoni Gigaline fiber optics cable data sheet

Page 1: LeoniLeoni Gigaline fiber optics cable data sheet

INDUSTRY

GigaLine ® outdoor cable, central loose tube 2500N

Fibre optic outdoor cable, single tube, longitudinally watertight, with corrugated steel tape armour

TypeKL-A-DQ(ZN)2Y(SR)2Y 1 x m G/E..

Construction:1) Fibre:

single mode fibre E9..10/125 µmmulti mode fibre G50/125 µmmulti mode fibre G62.5/125µmColour code:fibres 1-12: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink Fibres 13-24 with black ring sign: red, green, blue, yellow, white, grey, brown, violet, turquoise, nature, orange, pink

2) Core:gel-filled loose tube up to 12 fibres Ø 2.9mm, up to 24 fibres Ø 3.5mm

3) Strain-reliefaramid yarns/glass rovings

4) Sheath:PE

5) Armour:sheath with corrugated steel tape

6) Sheath:PE, sunlight resistantColour outer sheath:Jet black RAL-9005

Fibre quality:0,36F3,5/0,22H18; E9..10 low OH, OS23.0B250/0.7F800-GBE500/1000; G62.5/125 OM1e2,5B600/0,7F1200-GBE750/2000; G50/125 OM2e2.5B1500/0.7F500-10GBE300; G50/125 OM3 bendable

Printing Inkjet:LEONI GigaLine A-DQ(ZN)2Y(SR)2Y n x m $fibre type$ $~~$ $reel no.$ $ $meter mark$

Temperature rangeTransport and storage -25°C to +70°C During installation -5°C to +50°C After installation -25°C to +60°C

Bending radiusAfter installation: 15 x outer diameter During installation: 20 x outer diameter

Longitudinal watertightness:IEC 60794-1-2 F5

Halogen acid gas emission:IEC 60754-1

Impact:IEC 60794-1-2 E4

Bending:IEC 60794-1-2 E11

Chemical continuance:Free of hazardous substances acc. to RoHS 2002/95/EG

Temperature test:IEC 60794-1-2, method F1

Strain-relief elements:IEC 60794-1-2, method E1

Crush:IEC 60794-1-2, method E3

LEONI Kerpen GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154, Email [email protected], www.leoni-infrastructure-datacom.com

Valid except for misprints and errors. Technical values subject to change (without notice).The original document is in German language. In case of doubt or conflict, the German language version will prevail.

Page 2: LeoniLeoni Gigaline fiber optics cable data sheet

Application:Outdoor cable for laying directly in the ground or in conduits and in case of high risk of damage by rodents, for MAN (city networks) and LAN ( campus/backbone). For installation in generic cabling acc. to ISO/IEC 11801, ISO/IEC 24702, EN 50173-1 and EN 50173-3.Ideal for all applications of Classes OF 300 to OF 10000 (depending on the fiber).Suitable for splicing

Installation:Outdoor, in conduits or on covered cable trays. For automated cable pulling via cable winches the use of tensile-force-recording equipment is obligatory.

INDUSTRY

GigaLine ® KL-A-DQ(ZN)2Y(SR)2Y

Fibre optic outdoor cable, single tube, longitudinally watertight, with corrugated steel tape armour

TypeKL-A-DQ(ZN)2Y(SR)2Y 1 x m G/E..

Dimensions: Outer-Ø: Weight: Strain-relief elements:

Crush resistance: Calorific value:

mm (ca.) kg/km (approx.) N (max.) Long termN / dm (max.)

Short termN / dm (max.)

MJ / m(approx.)

kWh / m(approx.)

1x2 12,5 160 2500 2500 3500 1,80 0,50

1x4 12,5 160 2500 2500 3500 1,80 0,50

1x6 12,5 160 2500 2500 3500 1,80 0,50

1x8 12,5 160 2500 2500 3500 1,80 0,50

1x10 12,5 160 2500 2500 3500 1,80 0,50

1x12 12,5 160 2500 2500 3500 1,80 0,50

1x24 12,5 160 2500 2500 3500 1,80 0,50

Dimensions: Low OH OS2E9...10/125

GBE 750/2000 OM2eG50/125

10GBE300 OM3 bendableG50/125

1x2 LKD8AC700K10000 * *

1x4 LKD8AC700K20000 * *

1x6 LKD8AC700K30000 LKD8AA200K30000 *

1x8 LKD8AC700K40000 * *

1x10 LKD8AC700K50000 * *

1x12 LKD8AC700K60000 LKD8AA200K60000 LKD8AA500K60000

1x24 LKD8AC700K90000 * LKD8AA500K90000

* on request