Left Ha ow S // Right Ha S /3-/ · C on-Tech Systems was founded in 1985 and is a fam-ily owned...
Transcript of Left Ha ow S // Right Ha S /3-/ · C on-Tech Systems was founded in 1985 and is a fam-ily owned...
INN
ER
ø
d Dø
Left Hand (shown), Sizes 30/16-52/26Right Hand, Sizes 73/53 - 103/78-51
TITAN THREADCTS ®/ TITAN IBO® Hollow Bar
Con-Tech Systems was founded in 1985 and is a fam-ily owned company. Since inception not only have we remained close to our roots with our innovative Strand and Bar products, but we have also developed and pro-moted many other unique and innovative products, in-cluding introducing the CTS®/TITAN IBO® Hollow Bars to the North American market, to allow our customers to complete a variety of many difficult projects.
With this wide selection of products still available to our customers today we are able to service not only large in-ternational contractors but also small owner operators.
Through our several production plants and offices locat-ed across Canada and the USA; from British Columbia to Ontario, from Washington State, to North Carolina and Florida, we are able to service any of your project needs.
... page 2
Contents:
Company Introduction:
CoverCompany Profile......................................... Page 2CTS®/TITAN IBO® Hollow Bars.................... Page 3Our Commitment/Applications................. Page 4Typical Applications.................................... Page 5Applications................................................ Page 6Application Details...................................... Page 7Advantages................................................. Page 8Installation.................................................. Page 9 CTS®/TITAN IBO® Hollow Bar Tech Data..... Page 10CTS®/TITAN IBO® Hollow Bar Tech Data..... Page 11Corrosion Protection.................................. Page 12Sacrificial Steel Loss Tech Data................... Page 13Drill Bits...................................................... Page 14Indicative Grout Body Diameters................ Page 15Accessories................................................. Page 16-17Project photo Gallery.................................. Page 18-19Back Cover: Contact Information
CTS® / TITAN IBO® Hollow Bar
... page 3
CTS®/TITAN IBO® Hollow Bars:
The CTS®/TITAN IBO® (Injection Bore) Hollow Bars were devised in Germany by Mr. Ernst Friedrich Ischebeck in 1983 and introduced into North America by Con-Tech Systems Ltd. Ischebeck Titan’s ground engineering solutions provide engineers in the construction and civil engineering industries with a new dimension in structural and geotechnical reinforcement, retention and stabilization techniques.
The CTS®/TITAN IBO® ground engineering solutions utilize a hollow steel bar which has a continuous thread running along its external surface. A suitable drill bit is fitted to the end of the bar to penetrate the structure or material requiring stabilization and a drill rig is used to install the bar into the desired position. Grout is injected through the hollow bar and ejected from apertures in the drill bit during the drilling. Pressure then forces the grout back along the outside of the bar to form a strong, monolithic stabilizing structure while improving the surrounding ground.
CTS®/TITAN IBO® ground engineering techniques provide solutions for anchor, soil nail, pile, rock bolt or ground improvement applications, with a wide variety of bar sizes, drill bits and accessories available to suit every requirement and condition.
The versatility of the CTS®/TITAN IBO® solution is evident in the number and variety of projects on which it has been used, often providing a more economical, efficient and effective alternative to traditional drilling and engineering methods.Expert technical advice on product selection and scheme design is always available from Con-Tech System’s qualified engineers.
CTS® / TITAN IBO® Hollow Bar
Phoenix Sky Harbour Airport Terminal 4 Expansion
• Contractor: Scheffler Nevada Corp.• Location: Phoenix, AZ
CTS®/TITAN IBO® Micropile Foundation.
... page 4
Our Commitment:Con-Tech Systems is committed to providing our customers with the best quality products and service. We take pride in our strict production process which ensures full customer satisfaction from the moment an order is placed. We have highly trained, professional staff that assist you in selecting the right product for your application.
• Micropiles• Soil Nails• Anchors
Typical Applications:
CTS® / TITAN IBO® Hollow Bar
Woodbridge NJ
Princeton
Atlantic Yards
Devil’s Slide Repair
Albany Medical Center
Kent Ave., Brooklyn NY
Kent Ave., Brooklyn NY Berth 14, Newark, NY
Berth 14, Newark, NY
... page 5
Typical Applications:
CTS® / TITAN IBO® Hollow Bar
Low Level Road, North Vancouver in progress, ... and after completion
Quartz Creek Bridge Foundation Repair
Quartz Creek Bridge
Salmon River Project. Idaho
Quartz Creek Bridge Anchor Testing
Exhumed Pile, NYC
... page 6
Applications:CTS® / TITAN IBO® Hollow Bar
• Soil Nails
• Micropiles
• Anchors
Soil Nailing is a method of earth reinforcement. It is a very economical process which allows a controlled im-provement of the natural stability of the soil. CTS®/TITAN IBO® Hollow Bar Soil Nails provide fric-tion, shear and tension strength in loose materials, combining all into a new monolithic structure.
A micropile is a small-diameter, drilled and grouted non-displacement pile in which most of the applied load is resisted by the steel reinforcement. A micropile can work in either tension or compression applications. CTS®/TITAN IBO® Hollow Bar Micropiles are a sim-ple, one step solution since the drilling element is also the grout conduit and the steel reinforcement element of the pile. The micropile is usually connected to the structure via a pile cap and is perfect for structural re-pairs and underpinning.
An Anchor is a steel element that is grouted into the ground and is stressed against a structure to resist movement. The CTS®/TITAN IBO® Hollow Bar An-chors can be fitted with special bond breaker material to enable the load transfer to the bond length.
... page 7
Application Details: CTS® / TITAN IBO® Hollow Bar
MicropileSOIL NAILANCHORMICRO PILE
CONCRETE
FINAL GROUT
FLUSHING/STABILIZING GROUT& GROUND IMPROVEMENT
GROUND
AnchorSOIL NAILANCHORMICRO PILE
CONCRETE
FINAL GROUT
FLUSHING/STABILIZING GROUT& GROUND IMPROVEMENT
GROUND
Soil NailSOIL NAILANCHORMICRO PILE
CONCRETE
FINAL GROUT
FLUSHING/STABILIZING GROUT& GROUND IMPROVEMENT
GROUND SOIL
NA
ILA
NC
HO
RM
ICR
O P
ILE
CO
NC
RET
E
FIN
AL
GR
OU
T
FLU
SHIN
G/S
TAB
ILIZ
ING
GR
OU
T&
GR
OU
ND
IMPR
OV
EMEN
T
GR
OU
ND
SOIL
NA
ILA
NC
HO
RM
ICR
O P
ILE
CO
NC
RET
E
FIN
AL
GR
OU
T
FLU
SHIN
G/S
TAB
ILIZ
ING
GR
OU
T&
GR
OU
ND
IMPR
OV
EMEN
T
GR
OU
ND
... page 8
CTS® / TITAN IBO® Hollow Bar
Advantages of CTS®/TITAN IBO® Hollow Bar:
Example of a Reticulated Micropile Wall• Owner: CN Rail• Contractor: Geo-Foundations Contractors Inc.• Location: Ontario, Canada
Installation of an array of 125 micropiles 39.4’ (12 meters deep), with half of them vertical while the other half are inclined towards the core of the embankment. The piles are then tied to a 203’ (62 meter) long reinforced concrete beam. This project was completed without any interruption to the rail traffic.
Geotechnical Benefits:• Extremely low settlement characteristics • Enhanced mechanical bond with surrounding ground (ground improvement)• Minimal disturbance during installation• Works in compression and tension
Material Benefits:• No requirement for double corrosion protection in permanent works• On site fabrication provides design flexibility• Wide variety of drill bits to suit different ground conditions• CTS®/TITAN IBO® Hollow Bars provide a range of working loads.
Production Benefits:• Single step casing free operation significantly improves productivity• Suitable for difficult and restricted access situations• Ability to use smaller drilling rigs reduces mobilization costs• Dramatically increased production rates• Permits top down mini jet grouting in saturated clays and silts complete with reinforcing bar.• Remote de-coupling unit facilitates underwater piling from barges or drill platforms• No harmful vibrations or noise• Minimal spoil
... page 9
Installation:
CTS® / TITAN IBO® Hollow Bar
The CTS®/TITAN IBO® Hollow Bar solution uses the hollow threaded bar as a conduit for either air, water, or grout flushing medi-ums. The medium used is dependent on the ground conditions encountered. For exam-ple: rock would normally require air or wa-ter whereas soft or collapsing ground would require grout.
Grout FlushingThen density of the grout is varied depend-ing on the ground conditions; the greater the need to support the annulus the thicker the grout required. Typically a W/C ratio of between 0.7 and 0.4 would be used.
The flushing head transmits the rotary and percussive forces from the drilling machine to the drill bit, while allowing continuous pumping of the flushing medium through the CTS®/TITAN IBO® Hollow Bar.
The flushing medium exits the apertures of the drill bit under pressure, creating a con-tinuous pressure scouring action against the sides of the drill hole. This action exposes the harder parts of the hole while flushing and removing the softer parts to the sur-face therefore improving the surrounding ground.
When each bar has been drilled to depth it is withdrawn back up the mast and then re-drilled in a reaming action to improve cut-tings return and increase the scouring of the grout flush.
Scouring creates a very rough, irregular shaped grout body with a much greater bond and friction to the soil, providing great-er pull-out resistance and lower settlement characteristics.
Devil’s Slide Repair
INNER ø
d
D ø
Left
Hand
(show
n),
Siz
es
30/1
6-5
2/2
6
Rig
htH
and,S
izes
73/5
3-
103/7
8-5
1
TIT
AN
TH
RE
AD
... page 10
CTS® / TITAN IBO® Hollow Bar
CTS®/TITAN IBO® Hollow Bar Technical Data: PRODUCT SPECIFICATIONS
INN
ER
ø
d Dø
Left Hand (shown), Sizes 30/16-52/26Right Hand, Sizes 73/53 - 103/78-51
TITAN THREAD
1 mm = 0.03937 in 1 m = 3.281 ft 1 kN = 0.225 kips 1 kN/mm2 = 145 ksi 1 kg/m = 0.672 lbs/ft
The CTS®/TITAN IBO® Hollow Bar type denotes external diameter of bar followed by its interal diameter. For example, a TITAN 30/16 Bar has an external diameter of 30mm and an internal diameter of 16mm.
KEY FEATURES:
1. Utilization of a CTS®/TITAN IBO® Hollow Bar as the reinforcing Bar. From the static point of view, a hol-low bar is superior to a solid rod of the same cross sectional area with respect to bending moment, shear resistance and surface bond/friction.
2. The CTS®/TITAN IBO® Hollow Bar is manufactured from high yield micro alloy, high quality structural steel offering high notch toughness > 40J @ -20 Cel-sius. This steel is not affected by hydrogen embrittle-ment or by stress crack corrosion. It has at least the mechanical properties and chemical compositions of ASTM A-706.
3. The threads on the CTS®/TITAN IBO® Hollow Bar are formed much like the ribs on a reinforcing bar fab-ricated according to ASTM-A-706. The deep TITAN threads result in 2.4 times higher bond friction com-pared to standard drill steel rope-threads.
4. Continuous threads guarantee that the CTS®/TITAN IBO® Hollow Bar can be cut or coupled anywhere along its length. A thread pitch of 6 degrees elimi-nates the need for locking nuts at each coupling.
5. Certified to ISO 9001.
For the most current technical information please go to our website: www.contechsystems.com
INNERø
d
Dø
LeftHand(shown),Sizes30/16-52/26
RightHand,Sizes73/53-103/78-51
TITANTHREAD
... page 11
CTS® / TITAN IBO® Hollow Bar
CTS®/TITAN IBO® Hollow Bar Technical Data: PRODUCT SPECIFICATIONS
Bar Size Nominal DiameterEffective
Cross-Section
Load Capacity WeightLeft Hand
/ Right Hand
D Ø / INNER Ø Inside Outside Ultimate YieldD Ø G.U.T.S.
mm in in in² kips kips lbs./lf. Threadmm mm mm² kN kN kg/m
30/16 0.62 1.18 0.53 55.1 42.7 1.8 LEFT16 30 340 245 190 2.7
30/11 0.43 1.18 0.64 72.0 58.5 2.2 LEFT11 30 415 320 260 3.3
40/20 0.78 1.57 1.13 121.4 95.6 3.8 LEFT20 40 730 540 425 5.6
40/16 0.62 1.57 1.40 148.4 118.1 4.8 LEFT16 40 900 660 525 7.2
52/26 1.02 2.05 1.94 208.0 164.2 6.7 LEFT26 52 1250 925 730 9.9
73/53 2.08 2.87 2.50 260.8 218.1 8.9 RIGHT53 73 1615 1160 970 13.2
73/45 1.77 2.87 3.50 356.3 285.5 12.0 RIGHT45 73 2260 1585 1270 17.8
103/78 3.07 4.06 4.87 510.3 404.7 17.0 RIGHT78 103 3140 2270 1800 25.3
Please contact us for availability of the following sizes:73/35 1.38 2.87 4.20 419.3 321.5 14.2 RIGHT
35 73 2710 1865 1430 21.273/56 2.20 2.87 2.11 232.7 186.6 7.3 RIGHT
56 73 1360 1035 830 10.8103/43 1.69 4.06 9.34 934.1 763.9 31.8 RIGHT
43 103 6023 4155 3398 47.3103/51 2.00 4.06 8.80 822.8 600.3 30.0 RIGHT
51 103 5680 3660 2670 44.6127/103 4.05 5.00 5.39 521.6 456.4 19.4 RIGHT
103 127 3475 2320 2030 28.9196/130 5.12 7.72 25.11 2315.5 1607.8 85.7 RIGHT
130 196 16200 10300 7152 127.5Note: Subject to change without notice.
Imperial values converted from metric values; July 2010
ONE MORE SIZE? 08/04/20151 mm = 0.03937 in 1 m = 3.281 ft 1 kN = 0.225 kips 1 kN/mm2 = 145 ksi 1 kg/m = 0.672 lbs/ft
The CTS®/TITAN IBO® Hollow Bar type denotes external diameter of bar followed by its interal diameter. For example, a TITAN 30/16 Bar has an external diameter of 30mm and an internal diameter of 16mm.
For the most current technical information please go to our website: www.contechsystems.com
... page 12
CTS® / TITAN IBO® Hollow Bar
Corrosion Protection:
The CTS®/TITAN IBO® Hollow Bar ground engi-neering products can be used in permanent appli-cations if the correct installation and anchorage protection are utilized without any additional cor-rosion protection. The high yield steel has a low carbon content that exceeds the Carbon Equiva-lent Value (CEV) of ≤ 0.55% as prescribed in ASTM A706. A result of this low carbon content is that the steel is very ductile and is not susceptible to stress, corrosion cracking, or hydrogen embrittle-ment.
Also, unlike Rope Thread (R-thread), the CTS®/TITAN IBO® Hollow Bar thread is coarse, widely spaced and has a groove taken out of the crown. This thread type conforms to ASTM A706 and in-duces controlled cracking of the grout along the length of the bar.
To prevent corrosion from occurring, a crack width in the protective cementitious barrier must be less than 0.1 mm. Shear friction test in con-junction with crack width measurements have been carried out on the CTS®/TITAN IBO® Hollow Bar thread. The results have shown that the fre-quency of cracking within the grout body can be controlled to such an extent that the crack widths stay well below the permitted 0.1mm, along the anchor length including couplers. Identical tests have also been carried out using the R-thread product. However, the crack width was 0.2mm over the permitted 0.1mm, and therefore grout cannot be considered as an acceptable cementi-tious protective barrier on R Thread Bars.
If highly corrosive soil is encountered, Con-Tech Systems can provide the CTS®/TITAN IBO® Hol-low Bar product with an INOX steel. This is a stainless steel that will not corrode in extremely aggressive environments.
If you are uncomfortable that your anchorage
head zone cannot be properly protected, the bars can be protected with metallic or epoxy coatings. We have also included the sacrificial loss table for the CTS®/TITAN IBO® Hollow Bar product for all of the sizes and various soil conditions on the fol-lowing page. This table is derived from the EN 14199.
... page 13
CTS® / TITAN IBO® Hollow Bar
Sacrifical Steel Loss Technical Data Table 1:
Cross SectionBar Size mm² Ground Aggressivity / Soil Types Diameter
loss [mm]Reduced
area% loss Diameter
loss [mm]Reduced
area% loss Diameter
loss [mm]Reduced
area% loss
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 316 7.18 0.90 304 10.71 1.20 292 14.19
polluted natural soil and industrial grounds 1.50 280 17.64 2.25 251 26.07 3.00 224 34.23
aggressive natural soil (swamp, marsh, peat,...) 1.75 270 20.48 2.50 242 28.82 3.25 215 36.90
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 292 14.19 1.70 272 19.91 2.20 253 25.51
non-compacted and aggressive fills (ashes, slag,...) 3.25 215 36.90 4.50 171 49.79 5.75 129 61.96
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 390 5.93 0.90 378 8.84 1.20 366 11.72
polluted natural soil and industrial grounds 1.50 355 14.56 2.25 326 21.53 3.00 298 28.27
aggressive natural soil (swamp, marsh, peat,...) 1.75 345 16.91 2.50 316 23.80 3.25 289 30.48
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 366 11.72 1.70 347 16.44 2.20 328 21.07
non-compacted and aggressive fills (ashes, slag,...) 3.25 289 30.48 4.50 244 41.13 5.75 203 51.20
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 696 4.67 0.90 679 6.98 1.20 662 9.27
polluted natural soil and industrial grounds 1.50 646 11.54 2.25 605 17.13 3.00 565 22.59
aggressive natural soil (swamp, marsh, peat,...) 1.75 632 13.41 2.50 592 18.96 3.25 552 24.39
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 662 9.27 1.70 635 13.04 2.20 608 16.76
non-compacted and aggressive fills (ashes, slag,...) 3.25 552 24.39 4.50 488 33.16 5.75 426 41.60
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 865 3.89 0.90 848 5.80 1.20 831 7.71
polluted natural soil and industrial grounds 1.50 814 9.59 2.25 772 14.25 3.00 731 18.80
aggressive natural soil (swamp, marsh, peat,...) 1.75 800 11.16 2.50 758 15.77 3.25 717 20.29
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 831 7.71 1.70 802 10.84 2.20 775 13.94
non-compacted and aggressive fills (ashes, slag,...) 3.25 717 20.29 4.50 652 27.61 5.75 588 34.65
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 1,206 3.53 0.90 1,184 5.28 1.20 1,162 7.01
polluted natural soil and industrial grounds 1.50 1,141 8.74 2.25 1,088 13.00 3.00 1,035 17.19
aggressive natural soil (swamp, marsh, peat,...) 1.75 1,123 10.17 2.50 1,070 14.40 3.25 1,018 18.57
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 1,162 7.01 1.70 1,126 9.88 2.20 1,091 12.72
non-compacted and aggressive fills (ashes, slag,...) 3.25 1,018 18.57 4.50 933 25.36 5.75 851 31.96
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 1,549 4.06 0.90 1,517 6.07 1.20 1,485 8.08
polluted natural soil and industrial grounds 1.50 1,452 10.07 2.25 1,372 15.03 3.00 1,293 19.93
aggressive natural soil (swamp, marsh, peat,...) 1.75 1,426 11.73 2.50 1,346 16.67 3.25 1,267 21.55
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 1,485 8.08 1.70 1,431 11.40 2.20 1,378 14.70
non-compacted and aggressive fills (ashes, slag,...) 3.25 1,267 21.55 4.50 1,138 29.57 5.75 1,011 37.43
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 2,173 3.83 0.90 2,141 5.27 1.20 2,109 6.70
polluted natural soil and industrial grounds 1.50 2,076 8.13 2.25 1,996 11.67 3.00 1,917 15.17
aggressive natural soil (swamp, marsh, peat,...) 1.75 2,050 9.31 2.50 1,970 12.84 3.25 1,891 16.33
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 2,109 6.70 1.70 2,055 9.08 2.20 2,002 11.43
non-compacted and aggressive fills (ashes, slag,...) 3.25 1,891 16.33 4.50 1,762 22.06 5.75 1,635 27.68
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 3,047 2.96 0.90 3,001 4.43 1.20 2,955 5.90
polluted natural soil and industrial grounds 1.50 2,909 7.36 2.25 2,794 11.01 3.00 2,681 14.62
aggressive natural soil (swamp, marsh, peat,...) 1.75 2,871 8.58 2.50 2,757 12.21 3.25 2,643 15.82
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 2,955 5.90 1.70 2,878 8.34 2.20 2,802 10.76
non-compacted and aggressive fills (ashes, slag,...) 3.25 2,643 15.82 4.50 2,457 21.76 5.75 2,273 27.62
undisturbed natural soils (sand, silt, clay, schist, ...) 0.60 5,587 1.64 0.90 5,540 2.46 1.20 5,494 3.27
polluted natural soil and industrial grounds 1.50 5,448 4.08 2.25 5,333 6.10 3.00 5,220 8.11
aggressive natural soil (swamp, marsh, peat,...) 1.75 5,410 4.76 2.50 5,295 6.77 3.25 5,182 8.77
non-compacted and non-aggressive fills (clay, schist, sand, silt, ...) 1.20 5,494 3.27 1.70 5,417 4.62 2.20 5,341 5.97
non-compacted and aggressive fills (ashes, slag,...) 3.25 5,182 8.77 4.50 4,995 12.07 5.75 4,810 15.32
30/16 340
50 years 75 years 100 years
52/26 1250
73/53 1615
30/11 415
40/20 730
40/16 900
103/51 5680
73/45 2260
103/78 3140
Note: Table based on: EN 14199 1 mm = 0.03937 in 1 mm2 = .0015 sq in
... page 14
CTS® / TITAN IBO® Hollow Bar
Accessories:
Accessories: Drill Bits
The CTS®/TITAN IBO® Hollow Bar offers a wide variety of accessories to complement the entire Hollow Bar range, providing the flexibility to install the bar in diverse ground conditions with a variety of drill bits to suit different applications. Our comprehensive range of accessories includes Couplers, Dome Nuts, Centralizers, Adaptor Bits, Wedge Discs and Flushing Heads.
Standard Cross Cut Bit Button Bit
Carbide Cross Cut BitClay Bit
... page 15
CTS® / TITAN IBO® Hollow Bar
Indicative grout body diameters:
ANCHOR/PILE TYPE
DRILL BITDIAMETER
mmROCK mm
COHESIVE SOIL
SAND AND GRAVEL-SAND
mm
MEDIUM AND COARSE GRAVEL
mm
TITAN 30 hardened clay bit 75 100 125 150
TITAN 30 hardened clay bit 95 120 145 170
TITAN 30 cross cut drill bit 76 100 125 150
TITAN 30 cross cut drill bit 90 115 140 165
TITAN 30 carbide cross cut drill bit 46 46
TITAN 30 button drill bit 51 51
TITAN 30 carbide button drill bit 51 51
TITAN 40 hardened clay bit 110 135 160 185
TITAN 40 hardened clay bit 150 175 200 225
TITAN 40 cross cut drill bit 90 115 140 165
TITAN 40 cross cut drill bit 115 140 165 190
TITAN 40 carbide cross cut drill bit 70 70
TITAN 40 button drill bit 70 70
TITAN 40 carbide button drill bit 70 70
TITAN 40 carbide button drill bit 90 90
TITAN 52 hardened clay bit 130 155 180 205
TITAN 52 hardened clay bit 175 200 225 250
TITAN 52 cross cut drill bit 115 140 165 190
TITAN 52 cross cut drill bit 130 155 180 205
TITAN 52 carbide button drill bit 115 115
TITAN 73 hardened clay bit 200 225 250 275
TITAN 73 cross cut drill bit 130 155 180 205
TITAN 73 cross cut drill bit 175 200 225 250
TITAN 73 carbide cross cut drill bit 130 130 155 180 205
TITAN 73 carbide button drill bit 130 130
TITAN 103 hardened clay bit 220 245 270 295
TITAN 103 hardened clay bit 280 305 330 355
TITAN 103 cross cut drill bit 175 200 225 250
TITAN 103 carbide cross cut drill bit 175 175
TITAN 103 carbide button drill bit 175 175
* Note: Only if our installation procedures are followed as described.
... page 16
Accessories: Couplers & Dome NutsCTS® / TITAN IBO® Hollow Bar
Coupler
Spherical Dome Nut
... page 17
Accessories: Centralizers, Wedge Discs, Flushing HeadCTS® / TITAN IBO® Hollow Bar
Centralizer
Wedge Disc
Flushing Head
... page 18
Project Photo Gallery....CTS® / TITAN IBO® Hollow Bar
Sitka Dock, Alaska
Sitka Dock, AlaskaSalmon River Project, Idaho
Caltrans Highway 92
... page 19
CTS® / TITAN IBO® Hollow Bar
Gaillard Center, Charleston SC
City Point, Brooklyn NY
Gaillard Center
Kosair Hospital, Louisville KY
Limited Overhead
Caltrans, at Gorda
City Point, Brooklyn NY
INNERø
dDø
LeftHand(shown),Sizes30/16-52/26RightHand,Sizes73/53-103/78-51
TITANTHREAD
INN
ER
ø
d Dø
Left Hand (shown), Sizes 30/16-52/26Right Hand, Sizes 73/53 - 103/78-51
TITAN THREAD
Version: January 2017
Memberships:Partnerships:
Website: www.contechsystems.com
Eastern Locations:Sales & Production: • Brockville, ON, Canada
Tel: 613-342-0041• Charlotte, NC, USA
Tel: 704-494-3989Sales: • New Port Richey, FL, USA
Tel: 727-842-5760
Toll Free: 1-888-818-4826Email: [email protected]
Western Location:Sales & Production Plant:• 3736 South Tacoma Way, Tacoma, WA, 98409, USA Tel: 253-237-9008
Toll Free: 1-888-818-4826Email: [email protected]
Head Office: Sales & Production:• 8150 River Road, Delta, B.C. Canada V4G 1B5 Tel: 604-946-5571
Toll Free: 1-888-818-4826Email: [email protected]