LED T8 InstantFit Lamp…LED T8 InstantFit Lamp 16.5T8/48-4000 IF 10/1 Philips LED T8 InstantFit...
Transcript of LED T8 InstantFit Lamp…LED T8 InstantFit Lamp 16.5T8/48-4000 IF 10/1 Philips LED T8 InstantFit...
LED T8 InstantFit Lamp16.5T8/48-4000 IF 10/1
Philips LED T8 InstantFit Lamps are an ideal energy saving choice forexisting linear fluorescent fixtures.
Product data
• General CharacteristicsMain Application IndustrialCap-Base G13Rated Avg. Life(Hours)
40000 hr
Nominal Lifetimehours
40000 hr
• Light Technical CharacteristicsColor Code 840Beam Angle 160 DCorrelated ColorTemperature
4000 K
Approximate Lumens 2100 LmCRI 83Rated Luminous Flux 2100 LmLLMF - end nominallifetime
40000 %
Colour consistency 6 stepsRated Beam Angle 160 D
• Electrical CharacteristicsWattage 16.5 WVoltage 200-420 VLine Frequency 50/60 HzPower Factor 0.9 (min) -Dimmable NoRated Wattage 16.5 WStarting Time 0.5 (max) sWarm-up Time to60% Light Outp
instant full light
Energy savingproduct
Yes
Suitable for accentlighting
No
• Temperature CharacteristicsT-case maximum 45 (max) COperating tempera-ture
-20 (min), 45 (max) C
T-Storage -40 (min), 65 (max) C
• Environmental characteristicsEnergy EfficiencyLabel (EEL)
A+
Energy consumptionkWh/1000h
19 kWh
• Measuring ConditionsSwitching cycle 50000X
• Product DimensionsLength A1 1198.0 mmFixing Hole DistanceA2 Length
1205.0 mm
Length A3 1212.0 mmDiameter D 28 mmMounting hole diam-eter
25.68 mm
Circular outlinedimension
28 mm
• Approval & Application CharsVDE marking NoCE marking YesUL certificate NoRoHS compliance Yes
KEMA Keur certifi-cate
Yes
• Product DataProduct number 434886Full product name 16.5T8/48-4000 IF 10/1Short product name 16.5T8/48-4000 IF 10/1
Pieces per Sku 1eop_pck_cfg 10Skus/Case 10Bar code on pack 46677434885Bar code on case 50046677434880Logistics code(s) 929000288204eop_net_weight_pp 0.001 kg
Dimensional drawing
A1
A2
A3
D2
D1
16.5T8/48-4000 IF 10/1Product A1 (Norm) A2 (Norm) A3 (Norm) D1 (Norm) D2 (Norm)
TLED 1200mm 16.5W G13/840 1198.0 1205.0 1212.0 25.68 28
13
G13
Photometric data
200 400300 500 6000
40
80
20
60
700 800
100
[nm]
Inte
nsity (
%)
LEDtube 16.5 W /840 1200 mm T8
LED T8 InstantFit Lamp
© 2014 Koninklijke Philips N.V. (Royal Philips)All rights reserved.
Specifications are subject to change without notice. Trademarks are the property ofKoninklijke Philips N.V. (Royal Philips) or their respective owners.
www.philips.com/lighting
2014, November 29data subject to change
Installation, Ballast & Specification GuidePhilips LED T8 InstantFit Lamp
Please take the time to read this quick installation guide. The guide contains importantinformation and notes regarding the installation and operation.
• Please keep this Quick Installation Guide for future reference.
• Product is not dimmable
• Operates on instant-start ballasts only1.
• Philips LED T8 InstantFit lamps are not compatible with luminaires that use a remote starter.
• Modifications to the product void the warranty.
• Suitable to replace T8 fluorescent lamps as specified on the product label.
1 Please refer to www.philips.com/instantfit for latest ballast compatibility guide.
FF0002
DQD 507 Rev. 2012-05-22 Page 1
Certificate of Compliance Certificate: 2662008 Master Contract: 155397
Project: 2662008 Date Issued: September 27, 2013
Issued to: Philips Lighting Company, A Div. of 200 Franklin Square Dr. Somerset, NJ 08873 USA Attention: J. Cyre
The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent
indicator 'US' for US only or without either indicator for Canada only
Issued by:
Robin Huang
PRODUCTS
CLASS 3426 36 - LUMINAIRES- Luminaire Fittings LED Tubular Lamp Retrofit Kits
LED tubular lamps as direct replacements for 25W/48T8/HF, 28W/48T8/HF, 30W/48T8/HF, 32W/48T8/RS; F32T8, 25W; F32T8, 28W; F32T8, 30W; F32T8, 32W fluorescent lamp type, for dry or damp location use, Models 9290002840, 9290002841, 9290002842, 9290002862.
The Ballast models that the LED Tubular Lamp can be used with are:
Philips Models: GOPA-2P32-SC, GOPA-4P32-SC, GOPA-2P32-LW-SC, GOPA-4P32-LW-SC, IOPA-2P32-N, IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-LW-N, IOP-2P32-N, IOP-4P32-N, IOP-2P32-LW-N, IOP-4P32-LW-N, ICN-2P32-N, ICN-4P32-N ULT Models: B232I347HP-A, B432I347HP GE Models: GE232MAX347-N, GE432MAX347-N UltraSave Models: UT232347, UT432347
Instructions
1. Switch-off power to the luminaire
2. Remove diffuser (if provided)
3. Remove the existing fluorescent lamps from the luminaire.
- Note: Verify the fluorescent tube type is listed on the label of Philips LED T8 InstantFit lamp.
6. Switch on power to the luminaire.
1 2 Fluorescent 3 Fluorescent 5 LED T8 InstantFit 6 LED T8 InstantFit 6
CAUTION – IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT THE MANUFACTURERCAUTION – RISK OF FIRE. DO NOT INSTALL IN A PRE-HEAT LUMINAIREWARNING: RISK OF FIRE, USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL. SEE INSTRUCTIONS. THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIANTHIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY COMMUNICATIONSEQUIPMENT OR OTHER CRITICAL NAVIGATION OR COMMUNICATION EQUIPMENT OPERATING BETWEEN 0.45 – 30MHZ.
Lamps must be operated within an ambient fixture temperature of -4F (-20c) and 113F (45c) to ensure UL compliance.
MISE EN GARDE – SI LA LAMPE OU LE LUMINAIRE MONTRE UN FONCTIONNEMENT INAPPROPRIÉ (BOURDONNEMENT, CLIGNOTEMENT, ETC.), INTERROMPRE IMMÉDIATEMENT LE COURANT, ENLEVER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT.
MISE EN GARDE – RISQUE D’INCENDIE. NE PAS INSTALLER DANS UN LUMINAIRE DU TYPE À PRÉCHAUFFAGE.
CETTE LAMPE FONCTIONNE SEULEMENT SUR UN BALLAST ÉLECTRONIQUE. SI LA LAMPE NE S’ALLUME PAS LORSQUE LE LUMINAIRE EST MIS SOUS TENSION, RETIRER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT DE LA LAMPE OU UN ÉLECTRICIEN QUALIFIÉ.CE PRODUIT EST SUSCEPTIBLE DE CAUSER DE L’INTERFÉRENCE AVEC LES ÉQUIPEMENTS RADIO ET NE DEVRAIT PAS ÊTRE INSTALLÉPRÈS DES APPAREILS DE COMMUNICATION DE SÉCURITÉ MARITIME OU TOUT AUTRE ÉQUIPEMENT DE COMMUNICATION OU DE LA NAVIGATION QUI FONCTIONNE À UNE BANDE ENTRE 0,45 ET 30 MHZ.
© 2014 Koninklijke Philips N.V. All rights reserved.06/14
www.philips.com
Philips Lighting North America Corporation200 Franklin Square Drive Somerset, NJ 08873Phone: 85 5-486-2216
Philips Lighting281 Hillmount RoadMarkham, OntarioCanada L6C 2S3Phone: 800-555-0050
1 -3 Fluorescent 4 LED T8 InstantFit 6
U - Bend
AVERTISSEMENT: RISQUE D’INCENDIE. UTILISER UNIQUEMENT SUR PLACE DES LAMPES FLUORESCENTES PRÉCISÉES SUR L'ÉTIQUETTE. VOIR LES INSTRUCTIONS
Lampes doivent être exploités dans une température ambiante de fixation de-4F (-20c) et 113F (45c) pour assurer la conformité UL.
CES DISPOSITIFS NE DOIT ÊTRE UTILISÉE QU'AVEC APPAREILS D'URGENCE DE SORTIE OU FEUX D'URGENCE DE SORTIE
THESE DEVICES ARE NOT INTENDED FOR USE WITH EMERGENCY EXIT FIXTURES OR EMERGENCY EXIT LIGHTS.
5 LED T8 InstantFit
4-5. Install the Philips LED T8 InstantFit lamp (One for each fluorescent lamp removed, ensure pins are firmly seated in lampholders).
- For U-bend only, please ensure lamp is secured by clip
- Replace diffuser (if removed in step 2).