LED LUMINAIRE · 110 W 14,410 lm DOWNLIGHT 15 Wattage Lumens 15 W 1,100 lm DOWNLIGHT 9 Wattage...
Transcript of LED LUMINAIRE · 110 W 14,410 lm DOWNLIGHT 15 Wattage Lumens 15 W 1,100 lm DOWNLIGHT 9 Wattage...
b b’
c
c’ a
a’
Extremely Low Power
Extremely Low Power
LED T8 TUBE
Fluorescent lamp DLC QPL Min (1,900lm)Kowa T8 Tube Type LED
Wattage
Compare KOWA LED to Fluorescent lamp / Other LED
Characteristics at 25°C
※ Assuming a fixture using three fluorescent lamps consumes 88W.Actual results may vary.
Approx.
60%Energy Savings11.7 W
01 Wattage
160 lm/WOver※ In the case of 120V, 5,000K. Performance varies by the voltage & CCT.
02 Efficacy
03 Energy Savings
Light Distribution Diagrams (cd / 1000 [lm] ) Zonal Lumen Summary
Dimensions
11.7 W29.3 W 19.0 W
FG8C-40T-35/20/11F1
FG8C-40T-40/20/11F1
FG8C-40T-50/20/11F1
FG8C-40T-40/20/11F27
FG8C-40T-35/20/11F1
FG8C-40T-50/20/11F27
11.7 1,950
3,500
4,000
5,000
3,500
4,000
5,000
100-127
200-277
0.122-0.096
0.060-0.045
:a-a’
:b-b’
inchmm
47.1 47.4 47.7 1.0 1.1
A1 A2 A3 D1 D2
1,198 1,205 1,212 25.4 28.0
0-30 310 15.90-60 980 50.30-90 1,530 78.50-120 1,822 93.40-150 1,932 99.10-180 1,950 100.0
Flux (lm)Zone % of lamp
Light Distribution(cd/1,000lm)
0° 45°10° 199 19830° 188 17850° 168 14670° 138 10590° 105 71
Horizontal AngleVerticalAngle 90°
197167115500
Ceiling 20 0Walls 10 0Floor 30 10 30 10 30 10 30 10 30 10 30 10 10 0
55 51 40 38 31 30 35 34 28 28 26 26 21 1865 59 50 47 40 39 43 41 36 35 33 32 27 2473 66 58 54 48 45 50 47 42 41 39 38 32 2980 71 66 60 56 52 56 53 49 47 45 43 38 3486 75 72 65 62 58 62 58 54 52 49 48 42 3894 81 82 73 72 66 69 64 63 59 57 55 49 4499 85 88 78 79 71 74 69 68 64 62 59 54 49
103 88 93 81 85 75 78 72 73 68 66 63 58 52107 91 99 86 92 81 83 76 79 73 71 67 62 57110 93 103 89 97 85 87 79 83 76 74 70 65 60117 98 113 95 109 93 94 85 92 83 82 77 73 67
UTILISATION FACTOR - UF (Floor)
Utilization Factor(×0.01)
RefrectionFactor (%)
80 5070 30 10 50 30
30
2.5345
10
0.60.81
1.251.52
30
Room Index
Information provided is subject to change without notice. All values are design or typical values which measured under laboratory conditions and Kowa makes no warranty or guarantee, expressed or implied, that such performance will be obtained under end-use conditions.
LED LUMINAIRE
Contact us to schedule a lighting assessment. We will create a customized plan with energy-efficient LED solutions and an estimat-ed payback period. We will choose from a broad portfolio of ener-gy-efficient LED solutions including the latest KOWA LED lighting products.
The MathBy converting your existing fluorescent lamps with Kowa LED tubes, one may able to create an average 53-watt saving per fixture (assuming a standard fixture with three 4 ft. T8 fluorescent lamps consumes 88 W). This switch may save about 233 kilowatt hours (kWh) of electricity a year ― approximately a $25.60 utility cost reduction (based on an $0.11 kWh and 4,400 hours of operation). One may also anticipate less maintenance: a user of fixtures with fluorescent lamps may end up replacing old lamps and ballasts each year.
DLC QPL Min35% saving
Kowa+25% saving
HIGH BAY 100 WattageLumens
100 W13,000 lm
HIGH BAY 150 WattageLumens
150 W19,500 lm
HIGH BAY 200 WattageLumens
200 W26,000 lm
HIGH BAY 240 WattageLumens
240 W31,200 lm
HIGH BAY 178 178 W
23,318 lm
HIGH BAY 110 WattageLumens
WattageLumens
WattageLumens
110 W14,410 lm
DOWNLIGHT 15 WattageLumens
15 W1,100 lm
DOWNLIGHT 9 WattageLumens
9 W540 lm
GARAGE LIGHT 40 40 W
4,000 lm
GARAGE LIGHT 60 WattageLumens
60 W5,700 lm ... and more.
Calculations above assume the energy costs of $0.11 per kWh and a burn rate of 4400 hours a year. Actual energy savings may vary based on usage and other reasons.
$0
$50,000
$100,000
$150,000
$200,000
$250,000
1 2 3 4 5year
Flourescent
Kowa
DLC QPL Min
Lamp Type T8 Flourescent DLC QPL Min. KowaLamp Quantity 3 lamps 3 lamps 3 lampsLamp Watts 32 W 19 W 12 WLamp Watts of 3 Lamps 96 W 0 0Ballast Factor & Ballast Loss ▲ 8 W 0 03 Lamp System Wattage 88 W 57 W 35 W
Annual Operating Hours 4,400 hrs. 4,400 hrs. 4,400 hrs.Annual Energy Consumption (kWh) 387.200 kWh 250.800 kWh 154.440 kWhElectrical Cost Per kWh $0.11 /kWh $0.11 /kWh $0.11 /kWhAnnual Electrical Cost Per Fixtuee $42.59 /yr. $27.59 /yr. $16.99 /yr.
Number of Fixturre 1,000 fixtures 1,000 fixtures 1,000 fixturesAnnual Electrical Cost (1,000 Fixture) $42,592.00 /yr. $27,588.00 /yr. $16,988.40 /yr.
5 Year Cumulative Electrical Cost $212,960.00 /5 yrs. $137,940.00 /5 yrs. $84,942.00 /5 yrs.
5 Year Cumulative Electrical Cost Saving $0.00 $75,020.00 $128,018.00