LED 150W ARC-COB TM · 2019. 3. 14. · Designed for Easy Installation in New and Existing...

2
Designed for Easy Installation in New and Existing Fixtures, the HyLite LED Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs. With a Lamp Life of up to 60,000 hours, the HyLite LED Arc-Cob Lamps Significantly Reduce Relamping costs, thus decreasing Maintenance and Disposal Costs. The HyLite LED Arc-Cob Lamp enhances vision for better Optical Acuity, and reduces Light Pollution (No Wasted Light). Suitable for Fully Enclosed Fixtures, its Compact Size makes it the ideal Replacement for CFL, MV, HID, and HPS Lamps in Various Applications. • Fully Encapsulated: Shatterproof, High-Shock & High-Vibration Resistant • Instant Start and Restart: No Warm-up Time required • Quick & Easy Installation: No Ballast necessary. Direct Retrofit into existing socket by simply bypassing the Ballast. • Extremely Efficient: High Lumen Efficacy: 140 LpW with High CRI >80 • 350° Rotatable Base for Directional Lighting • Heat & Impact Resistant, UV Protected, Non-yellowing, Optical Grade Lens • Safe & Reliable: Isolated Circuit Design. Integral 1 kV Surge Suppressor and Protection. Includes a Free 20kA in-line Surge Protection Device for added Protection • Good Heat Dissipation with Proprietary-designed Heat Sink • No Electro-Magnetic (EMi) or Radio Frequency Interference (RFi) • Universal Voltage: 100-277V, AC • Ingress Protection: IP65. Complete protection against Contact, Dust Infiltration, and Water Splashes. • No UV Radiation – Does Not Attract Insects • Wide Ambient Operating Temperature: -40°F to +131°F [-40°C to +55°C] • Safe: Contain No Hazardous Materials; RoHS Compliant: No Lead, Mercury, Toxic Metals or Arsenic Gases. No Disposal Requirements. • Environmentally Friendly: 98% of the HyLite LED Lamp is Recyclable Page: 1 of 2 Incandescent HPS/HID CFL HyLite 225W 150W 80W 30W 87% 80% 63% Energy Savings (%)* * Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%! Replace with 30W HL-AC-30W-E39 100~277V, AC HyLite LED High Performance Arc-Cob Lamps - Up to 60,000 hour* Rated Performance Life. Outstanding Quality of Light with Energy Savings of up to 87% over Incandescent, 80% over HPS / MH Lamps and 63% over CFL. ARC-COB TM L E D 4” (102mm) 9” (225mm) Ø 3.6” (90mm) E39 5” (120mm) 1.9” (48.5mm) 30W HL-AC-30W-E39 100~277V, AC Lamp can be oriented in any position - does not affect or diminish the life of the Lamp Universal Burning Positioning Base Up Base Down Base Sideways 150W MH / HPS Equivalent *Depending upon the ambient temperature of the installation location FREE! 20 kA In-line Surge Protection Device Included. Additional Protection for your HyLite Arc-Cob Lamp at no Cost! NO LEAD, MERCURY, HEAVY METALS OR TOXIC GASES 98% RECYCLABLE High Performance LED Arc-Cob Lamp, 30W LED Product Partner Reliable and Long-Lasting Warranty 5 years Beam Angle Vibration and Shock Resistant Solid State Radiation-Free No Humming IR UV No IR/UV No Noise 140 LpW LM-79 Tested High Efficacy LM-80 Tested ISTMT Tested Reliability Reduction of up to 87% Energy Costs Wide & Uniform 120° For Enclosed Luminaires Suitable Zero Interference No EMi / RFi Up to 60,000 Hours Low Voltage Longer Life & Suitable for Damp Locations Enclosed Fixtures

Transcript of LED 150W ARC-COB TM · 2019. 3. 14. · Designed for Easy Installation in New and Existing...

Designed for Easy Installation in New and Existing Fixtures, the HyLite LED Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs. With a Lamp Life of up to 60,000 hours, the HyLite LED Arc-Cob Lamps Significantly Reduce Relamping costs, thus decreasing Maintenance and Disposal Costs.

The HyLite LED Arc-Cob Lamp enhances vision for better Optical Acuity, and reduces Light Pollution (No Wasted Light). Suitable for Fully Enclosed Fixtures, its Compact Size makes it the ideal Replacement for CFL, MV, HID, and HPS Lamps in Various Applications.

• FullyEncapsulated:Shatterproof,High-Shock&High-VibrationResistant

•InstantStartandRestart:NoWarm-upTimerequired

• Quick&EasyInstallation:NoBallastnecessary.DirectRetrofitinto existingsocketbysimplybypassingtheBallast.

• ExtremelyEfficient:HighLumenEfficacy:140LpWwithHighCRI>80

•350°RotatableBaseforDirectionalLighting

• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens

• Safe&Reliable:IsolatedCircuitDesign.Integral1kVSurgeSuppressor and Protection. Includes a Free 20kA in-line Surge Protection Device for added Protection

• GoodHeatDissipationwithProprietary-designedHeatSink

•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)

• UniversalVoltage:100-277V,AC

• IngressProtection:IP65.CompleteprotectionagainstContact, Dust Infiltration, and Water Splashes.

• NoUVRadiation–DoesNotAttractInsects

• WideAmbientOperatingTemperature:-40°Fto+131°F[-40°Cto+55°C]

•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements.

•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

Page:1of2

Incandescent HPS/HID CFL HyLite

225W 150W 80W 30W

87% 80% 63% Energy Savings (%)*

* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!

Replacewith

30WHL-AC-30W-E39100~277V, AC

HyLiteLEDHighPerformanceArc-CobLamps-Upto60,000hour*RatedPerformance Life. OutstandingQualityofLightwithEnergySavingsofupto87%overIncandescent,80%overHPS/MHLampsand63%overCFL.ARC-COB TM

LED

4”

(102mm)9”

(225mm)

Ø 3.6” (90m

m)

E39

5”

(120mm)

1.9” (48.5mm)

30WH

L-AC-30W

-E39100~277V, A

C

Lamp can be oriented in any position - does not affect or diminish the life of the Lamp

Universal Burning Positioning

BaseUpBaseDown BaseSideways

150WMH / HPSEquivalent

*Depending upon the ambient temperature of the installation location

FREE!20 kA

In-line Surge Protection Device Included.

Additional Protection for your HyLite Arc-Cob Lamp

at no Cost!

NOLEAD, MERCURY, HEAVY METALS

OR TOXIC GASES

98%RECYCLABLE

HighPerformanceLEDArc-CobLamp,30W

LED Product Partner

Reliable andLong-Lasting

Warranty

5years

Beam Angle

Vibration andShock Resistant

Solid State

Radiation-FreeNo Humming

IRUV

No IR/UV

No Noise

140 LpWLM-79 Tested

High Efficacy

LM-80 TestedISTMT Tested

Reliability

Reduction ofup to 87%

Energy Costs

Wide &Uniform

120°

For Enclosed Luminaires

Suitable

Zero

Interference

No EMi / RFi

Up to 60,000 Hours

Low Voltage

Longer Life&

Suitable for

Damp Locations Enclosed Fixtures

Page:2of2

Model Delivered Suggested InputLine Base Dimensions&Weight(each) No. Watts Lumens Install Height Current Type Diameter Height Weight

HL-AC-30W-E39 30 4200 <20ft.(6m) 108~300mA E39/E40(Mogul) 3.6”(90mm) 9”(225mm) 1.75lb.(780g)

Ideal for high-quality illumination in:

• WallScones • WallPacks

• FloodLights • ParkingGarageLights

• StreetLighting • ParkingLotLighting

• CanopyLights • WalkwayLighting

• LowBayLighting • SecurityLights

• PedestrianTunnels • Freezer&ColdStorageLights

• DrivewayLighting • Stairwells,CorridorsLighting

ARC-COB TM

LEDAs part of the company’s continuous product improvement program, HyLite reserves the right to change materialsor modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

Flux Out: 2297 lm

1 m3.2 ft.

Height

2 m6.5 ft.

3 m9.8 ft.

4 m13.1 ft.

5 m16.4 ft

Angle: 104.58° DiameterEAvg, Emax

415.1/1199 lx38.6/111.4 fc

103.8/299.8 lx9.6/27.9 fc

46.1/133.2 lx4.3/12.4 fc

26.0/75.0 lx2.4/7.0 fc

16.6/48.0 lx1.5/4.5 fc

C0/180, 66.4°, 71.1°

C90/270, 52.4°, 52.3°

Unit: cd0

30

60

90

120

150-/+180

-150

-120

-90

-60

-30

0

300

600

900

1200

1500

High Performance LED Arc-Cob Lamp, 30W

Photometrics

Intensity: (Unit, cd)

Average Beam Angle (50%): 121.1°

259 cm8.5 ft.

517 cm17.0 ft.

776 cm25.5 ft.

1035 cm34.0 ft.

1293 cm42.0 ft.

Warning - Risk of Fire or Electric Shock

• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will create a Hazardous and Fatal Working Environment.

• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.

• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. This will ensure Lumen Maintenance and extend its Working Life. When products are used in Outdoor Fixtures, ensure the space is Waterproof and Well Ventilated.

• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.

• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.

• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.

• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.

©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219

• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)

• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)

• Efficacy:143LpW • CRI:>80 • BeamAngle:120º • Max.THD(%):<20% • UniversalInputVoltage

• PowerFactor:>0.9 • Protection:IP65 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.

• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-30VA-480-240VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/

• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times

*Depending upon the ambient temperature of the installation location

Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast (if equipped) must be bypassed or removed from the fixture before installing the lamp. Eliminating theBallast savesadditional costs related to Maintenance, Energy Consumption and Performance.By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference.ItisSTRONGLYRECOMMENDED that the Reflector in the Fixture be removed for Optimum Thermal Management and better Heat Dissipation. This will ensure Lumen Maintenance and extend its Working Life. The installer MUST also ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.

Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an Electric Shock, or Fire.