Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

74
Lecture 7 • Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Transcript of Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Page 1: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Lecture 7

• Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Page 2: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Mechanical sensors: motivations.

How do we predict materials failure?

Aircraft wings (DC-10 metal fatigue: the wings suddenly

fell off)

Predict cracks and collapse in bridges and

buildings

Strength is the ability to withstand force or stress

Remember stress=force/area

Page 3: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

How do we measure fluid flow?

Beer taps-want to avoid losing the

bubbles

Grain silos-want to predict the rate of static buildup to avoid

explosions, yet maximize the throughput

Chemical reactions-want to ensure fluids

properly mixed

Usually want laminar flow, not

turbulent.

Page 4: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Mechanical Sensors

Mechanical sensors react to stimuli via some mechanical effect

The output may be: Mechanical (e.g. a dial or fluid level)

or

Electrical (e.g. a voltage or current)

• Definitions

• Force and pressure sensors

• Basic pressure sensors

• Medical pressure measurement systems

• Flow and flow-rate sensors.

Overview:

Page 5: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Force and Pressure SensorsHow do we measure an unknown force?

Acceleration Method

Apply force to known mass, measure acceleration.

Example: Force on Pendulum, apply force measure deflection.

Page 6: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

How do we measure hydrostatic pressure in fluids and liquids?

Blood/brain/spinal fluid pressure-how do we measure

non-invasively?

Hydraulic systems-bulldozer arms, car disk brakes/hydraulic lifts

How do divers know how much air they have left in

their tanks?

Page 7: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pressure sensors:

How do we tell when someone is walking down a corridor?

How can we weigh trucks as they pass over a road?

Page 8: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Force and Pressure Sensors

Gravity balance method.

Compare unknown force with action of gravitational force.

Example: Balance scale. (zero-balance method)

Page 9: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 10: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 11: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 12: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 13: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Spring Method

Use force to stretch or compress a spring of known strength, and measure displacement: F=kx , k is the spring constant.

Example: Fruit scales at supermarket

Page 14: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pressure-sensing method.Convert the unknown force to a fluid pressure, which is converted using a pressure sensor. Also known as deadweight sensor-used for weight calibrations.

AFP /

Page 15: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

From H. Norton, ‘Sensor and analyzer handbook’

Note that these all convert a pressure into an angular or

linear displacement. We can then sense the displacement

eledctronically or optically.

Some pressure sensing elements

Page 16: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pressure reference configurations

Page 17: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

If force is constant, pressure is static or hydrostatic:

• Beer in (untapped) keg

• Butane gas bottle.

If force is varying, pressure is dynamic or

hydrodynamic:

• Arterial blood pressure.

Units of Pressure:• 1 Pascal = 1 Newton/m2

• 1 atm (Atmospheric pressure) = 101325 Pa

• 760 torr = 1 atm

Pressure-sensing method.

Page 18: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pascal’s PrinciplePressure applied to an enclosed system is transmitted

undiminished to every portion of the fluid and container walls.

This is the basis of all hydraulics: a small

pressure can be made to exert a large force

by changing the dimensions of the

vessel

Page 19: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Applications of Pascal’s Principle

Disk brakes

Car Lift

Medical applications

Page 20: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Notes on Pascal’s principle

Pascal’s principle neglects the effects of gravity-need to add the contribution ρgh where ρ is the density, g the acceleration due to gravity, and h the height of the fluid.

Also, only true in hydrodynamic systems if change is quasi-static.Quasi-static means that after a small change is made, turbulence is allowed to die down then measurement is made.Examples are hydrodynamic systems where flow is non-turbulent and the pipe orifice is small compared with its length.

Page 21: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Bourdon tube sensorBourdon tube pressure sensor: curved or twisted tube, sealed at one end.

Measure resistance change as the pressure in the active tube

is changed

PVR

RVVout

Can be directly calibrated in Torr

As pressure inside changes, tube uncurls; this displacement can be transduced using

a variable sliding resistior

Page 22: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Membrane pressure sensors

Subdivided into bellows, thin plate and diaphragm sensors.

These work by measuring the deflection of a solid object by

an external pressure.

This displacement is then measured, and converted into a pressure reading

Membrane sensors can be made very small using micromachining; called microelectromechanical

systems (MEMS).

We will be discussing MEMS in more detail later.

Page 23: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Some MEMS sensors

• 1 μm high MEMs capacitive accelerometer: such devices are at the heart of car airbags.• Machined out of single silicon wafer• ‘Proof mass’ is freer to move in response to acceleration forces

Images from www.sensorsmag.com/articles/0203/14/

MEMs gyroscope based on ‘tuning fork’ design

Page 24: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Medical pressure measurement.

This is a major application for sensor technology.

Most common measurement is for blood pressure. More fully:

• Inter-cardiac blood pressure

• Arterial blood pressure

• Spinal fluid pressure• Central venous pressure

• Pulmonary artery pressure• Venous blood pressure

• Intraventricular brain pressure

The difference in these measurements is the range of measurement; we can often use the same sensor for different measurements

Page 25: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Medical students are often told there is an “Ohm’s law for blood”

P=F.R , Where:

• P is pressure difference in torr.

• F is flow rate in millilitres/second.

• R is blood vessel resistance in “periphial resistance units” (PRU) where 1 PRU allows a flow of 1 ml/s under 1 torr pressure.

This is misleading: in fact, blood vessels change diameter from systemic adjustments and from pulsatile pressure wave.

• minimally invasive

• sterile

• electrically insulated

Medical sensors should be:

Medical pressure sensors

Page 26: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

In fact, the flow rate is better given by

Poiseuille’s Law: L

RPF

8

4

Where:• F is flow in cubic centimetres/second

• P is Pressure in dynes per square centimetre

• η is coefficient of viscosity in dynes/square centimetre

• R is vessel radius in centimetre

• L is vessel length in centimetres

Page 27: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Blood Pressure Waveform

Four kinds of pressure:

T2 : Peak Pressure (systolic)

Tf: Minimum pressure (diastolic)

Dynamic Average (1/2 peak minus minimum)

Average pressure (arterial)

http://themodynamics.ucdavis.edu/mustafa/Pulse.htm

Page 28: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Mean arterial pressure is given by:

2

112

1 t

t

dtPtt

P

But clinically (for doctors and nurses in a hospital or sleep lab setting) a much simpler approximation is used:

3/)( 121 PPPP

Where P1 is diastolic Pressure and P2 is systolic pressure

Direct measurement of blood pressure is most accurate but also more dangerous (involves poking tubes into

arteries, very invasive.)

Blood Pressure Analysis

Page 29: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Open Tube Manometer

Sensing tube tube inserted directly into artery; mercury is poisonous, so need saline buffer

Measure pressure by height of sensing column:

Only used in intensive care units.

'sghghPP atm

=density of Manometer fluid

Page 30: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Sphygmomanometry (Korotkoff Method)• Inflatable cuff placed on upper arm and inflated until blood can’t flow

• Sound sensor (stethoscope) placed downstream

• Pressure is released

• When can hear blood squirting (Korotkoff sounds), the cuff pressure equals systolic (higher) pressure

• Hear continuous but turbulent flow when cuff pressure equals diastolic pressure

.

Page 31: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

The diamond Anvil

• One way to get huge pressures is to use diamonds to squeeze a sample

• Can achieve pressures up to 80 GPa (or even higher)

• So, like, is that big?

http://ituwebpage.fzk.de/ACTINIDE_RESEARCH/dac.htm

Page 32: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pressures are given in Atmospheres10-31 |- Non equilibrium "pressure" of hydrogen gas in intergalactic space. 10-28 |-10-25 |-10-22 |- Non equilibrium "pressure" of cosmic microwave background radiation. 10-19 |- Pressure in interplanetary space. 10-16 |-Best vacuum achieved in laboratory. 10-13 |- Atmospheric pressure at altitude of 300 miles. 10-10 |- Pressure of strong sunlight at surface of earth. 10-8 |- 10-7 |- Partial pressure of hydrogen in atmosphere at sea level. 10-6 |-Best vacuum attainable with mechanical pump. Radiation pressure at surface of sun. 10-5 |-Pressure of the foot of a water strider on a surface of water. Osmotic pressure of sucrose at concentration of 1 milligram per liter. 10-4 |-Pressure of sound wave at threshold of pain (120 decibels). Partial pressure of carbon dioxide in atmosphere at sea level. 10-3 |- Vapour pressure of water at triple point of water. 10-2 |-Overpressure in mouth before release of consonant p. Pressure inside light bulb. 10-1 |- Atmospheric pressure at summit of Mount Everest. 1 |-Atmospheric pressure at sea level. Pressure of ice skater standing on ice. 10 |-Maximum pressure inside cylinder of high compression engine. Air pressure in high-pressure bicycle tyre. 102 |-Steam pressure in boiler of a power plant. Peak pressure of fist on concrete during karate strike. 103 |-Pressure at greatest depths in oceans. 104 |-Pressure at which mercury solidifies at room temperature. Pressure at which graphite becomes diamond. 105 |-Highest pressure attainable in laboratory before diamond anvil cell. Radiation pressure of focused beam of pulsed laser light. 106 |-Highest pressure achieved with diamond anvil cell. Pressure at centre of Earth. 107 |-Pressure at centre of Saturn. 108 |-Pressure at centre of Jupiter. Radiation pressure at centre of sun. 1010 |- Pressure at centre of sun. 1013 |- 1016 |-Pressure at centre of red-giant star. Pressure at centre of white-dwarf star. 1019 |- 1022 |- 1025 |- Pressure at centre of superdense star. 1028 |- Pressure at centre of neutron star.

Relative pressure scale

Page 33: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

The Holtz cell

• The Holtz cell is a way to achieve huge pressures in a diamond anvil

• Uses a simple lever system to apply pressure

Page 34: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

The diamond Anvil

A photo of a working

diamond anvil at the institute

for transuranic elements, in

Europe

Page 35: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Lecture 8

Page 36: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Flow and Flow rate.

Laminar flow: smooth, orderly and regular

Turbulent flow: chaotic phenomena (whorls,

eddies, vortices)

Mechanical sensors have inertia, which can integrate out small variations due to turbulence

Flow in a capillary described by Pouiselle’s law.(But beware: only valid for laminar flow)

This begs the question: what makes flow laminar or turbulent?

Page 37: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Laminar and Turbulent flow

Laminar flow is characterised by :• smooth flow lines• all fluid velocity in same direction• flow velocity is zero at tube walls• flow speed increases closer to tube center

Page 38: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Reynolds Number.

DV

R Reynold’s Number R

Where

ρ is the fluid density (kg/m3)

V is the mean fluid velocity (m/s)

D is the capillary/pipe diameter (m)

is the viscosity of the fluid (Ns/m2)

R > 4000, flow is turbulent

R < 2000, flow is laminar

Page 39: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Flow Sensors

Many sensors measure flow rate.

Mass flow rate: mass transferred per unit time (kg/s)

Volumetric flow rate: volume of material per unit time (m3/s)

In gas systems, mass and volume rates are expressed in volume flow.

Mass flow referenced to STP (standard temperature and pressure) and converted to equivalent volume flow (eg sccm = standard cubic centimetres per minute)

Page 40: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Thermal flow Sensor

Hot wire anenometer:Cooling of resistive element by

fluid flow is measured by Voltmeter

Page 41: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Mass Flow controllers • Uses two thermometers which supply heat to the gas as well as measuring temperature• The faster that the gas flows, the more heat is removed from the upstream thermometer• The downstream thermometer also measures the heat flow, increasing accuracy• No contact between sensors and gases (no contamination)

Page 42: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Photo of a Mass Flow controller

• Can see that flow direction is important• Solid-state valves and interface • No moving parts=> no wear• Needs to be calibrated for each gas

Page 43: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

CVD diamond growth reactor

Page 44: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Steven’s MFC anecdote

Page 45: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Turbulence makes a difference!

Page 46: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Different growth

patterns with different flows

Page 47: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Mechanical obstruction sensors

Vane flow meter

Page 48: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Some more mechanical obstruction sensors

All these sensors turn a change in flow

rate into a change in linear or angular

displacement

Page 49: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Rotating mechanical obstruction sensors

sensors (a) and (b) turn a constant

flow rate into a constant angular

velocity

Page 50: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Rotor wheel flow sensor

• The rotating vane can be attached to a coil in a

magnetic field• The current generated

in the coil is proportional to the flow rate

Page 51: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Pressure drop sensorsWhen fluid in a pipe passes through a restriction there is a drop

in pressure.

Total pressure, Pt, after the constriction is Pt = Ps + Pd

• Ps is the static pressure,

• Pd is the dynamic (or impact) pressure

• Pt is sometimes called the stagnation pressure

How does this work?

Page 52: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Bernoulli’s Equation

constantPgzv221

Where:

• ρ is the fluid mass density (Ns2m-1)

• v is the fluid velocity (m/s)

• g is the acceleration due to gravity

• z is the height of fluid (often called head)

• P is the pressure on the fluid

• This is equivalent to saying that an element of fluid flowing along a streamline trades speed for height or for pressures• A consequence is that as flow velocity increases, the pressure on the vessel walls decreases

Page 53: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Differential pressure sensors•These sensors change the cross-sectional area A, which increases the velocity v.• Since the height of the fluid is constant, the pressure must decrease• The amount of material flowing per second does not change, so A1v1=A2v2

• Bernoulli’s equation becomes ½ ρv12+P1= ½ ρv2

2+P2 • Combine these expressions to get

][

2

]1)[(

)(2Pvgzv

2

211

221

2

1

ts

AA

PP

PP

Page 54: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Differential pressure sensors•These sensors change the cross-sectional area A, which increases the velocity v• Since the height of the fluid is constant, the pressure must decrease after the obstruction• The difference in pressures, combined with the cross-sectional area, tells us the velocity before the obstruction

Page 55: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Wire mesh flow sensor

www.fz-rossendorf.de/FWS/publikat/JB98/jb05.pdf

• Used to measure bubble propagation in gases• Uses grid of wires to measure electrical conductivity at wire crossing points

Page 56: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 57: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 58: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 59: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 60: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Images from wire mesh sensor

www.fz-rossendorf.de/FWS/publikat/JB98/jb05.pdf

• Note the area of laminar flow• Light areas are flowing faster

Page 61: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Cannula pressure-drop sensor

Page 62: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Ultrasonic flow sensors

• Ultrasonic waves are sound waves above human hearing (>20 kHz) • Typical frequencies are 20 kHz - 20 MHz.

Several types of ultrasonic sensors are available- the most

common are dynamic or piezoelectric sensors

• A typical dynamic sensor is a thin, low mass diaphragm, stretched over passive electromagnet.

• Such diaphragms operates at frequencies up to 100 kHz

• Good for Doppler shift intruder alarms (demo)

Remember that sound waves are longitudinal pressure waves

caused by vibrations in a medium

Page 63: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Ultrasonic flow sensors

• Many ultrasonic flow sensors consist of pairs of transducers• Each transducer can operate as either a source or a detector of sound waves

Page 64: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Dynamic Ultrasonic Sensors• As a generator of ultrasonic waves: the drive current creates a magnetic field which pushes against the permanent magnet.

• As a detector: the motion of the element induces a current in the drive coil

Page 65: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Piezoelectric ultrasonic transducers• We have encountered piezoelectrics in the context of force sensors

• An extension of this is the use of piezos to convert the compressions and rarefactions of a sound wave into an electrical signal

• Deforms a crystalline structure under potential stimulation

Operated at resonant frequency (quartz crystal reference)

Used in computers and wrist watches as a time reference.

Page 66: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Piezoelectric ultrasonic transducers

•The piezo transmits when an applied potential distorts crystal

• Receives when pressure wave distorts crystal

Page 67: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Measuring the speed of sound in a

crystal using ultrasound

Page 68: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.
Page 69: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Ultrasound baby photos

compsoc.dur.ac.uk/ ~ads/ultrasound.jpg

Page 70: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

The Doppler effect

We can use the Doppler effect to measure the velocity of a fluid.

Doppler effect is a shift in frequency from a moving source of waves.

Page 71: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

sc

ff

)cos(v2

For sound waves reflected off a moving object, there are two shifts:

One shift upon receiving the signal, the second upon transmitting.

The net shift is given by:

f is the Doppler shifted frequency

f is the source frequency

v is fluid velocity the angle between the ultrasonic beam and the fluid velocity

cs is the speed of sound in the fluid.

The Doppler effect

Page 72: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Doppler shift needs “stuff” to reflect off: either optically active molecules (eg Haemoglobin) or turbulence (bubbles)

Does not work with pure liquids.

Used as a non-invasive blood flow monitor

Powerful extra tool when combined with ultra-sonic imaging

Notes on the Doppler Shift

Page 73: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Doppler Blood measurement

• Doppler effect can be used to measure variations in blood flow speed

• Often used for measuring pulses on animals

http://www.indusinstruments.com/oldWebsite/Ultrasonic%20Blood%20Flow%20Measurement/dspw_setup.htm

Page 74: Lecture 7 Demos: U-tube manomoter, Archimedes principle, const fluid height, venturi flowmeter.

Ultrasonic transit-time flowmeter

Transit time TAB between A and B depends on the fluid velocity

)cos(2

2

D

TcV s

difference in transit times : T=TAB-TBA

D distance AB between sensors

angle between transit path and flow

V is velocity of fluidCs speed of sound in fluid