Learning from the States… Commonwealth of Massachusetts

24
of Massachusetts Department ENVIRONMENTAL PROTECTION Learning from the States… Commonwealth of Massachusetts Paul W. Locke Massachusetts Department of Environmental Protecti Office of Research & Standards One Winter Street, 8 th floor Boston, MA 02108 Phone: (617) 556-1160 Fax: (617) 556-1006 Email: [email protected] WWW: http://www.state.ma.us/dep ncy A. Fitzpatrick ssachusetts Department of Environmental Protection reau of Waste Site Cleanup rtheast Regional Office 5A Lowell Street lmington, MA 01887 one: (978) 661-7728 x: (978) 661-7615 ail: [email protected] W: http://www.state.ma.us/dep/nero

description

Learning from the States… Commonwealth of Massachusetts. Nancy A. Fitzpatrick Massachusetts Department of Environmental Protection Bureau of Waste Site Cleanup Northeast Regional Office 205A Lowell Street Wilmington, MA 01887 Phone: (978) 661-7728 Fax: (978) 661-7615 - PowerPoint PPT Presentation

Transcript of Learning from the States… Commonwealth of Massachusetts

Page 1: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Learning from the States…Commonwealth of Massachusetts

Paul W. LockeMassachusetts Department of Environmental ProtectionOffice of Research & StandardsOne Winter Street, 8th floorBoston, MA 02108

Phone: (617) 556-1160Fax: (617) 556-1006Email: [email protected]: http://www.state.ma.us/dep

Nancy A. FitzpatrickMassachusetts Department of Environmental ProtectionBureau of Waste Site CleanupNortheast Regional Office205A Lowell StreetWilmington, MA 01887

Phone: (978) 661-7728Fax: (978) 661-7615Email: [email protected]: http://www.state.ma.us/dep/nero

Page 2: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Timeline for MADEP Concerns with the Groundwater/Indoor Air Pathway

19891992

19931996

19982000

2001

Hillside School(Microwave Development Lab Site)

Revision of State Waste SiteCleanup Regulations (MCP)(Introduces a Privatized Program)

DEP Regional StaffEvaluate Vapor Intrusion Pathway(Nancy Fitzpatrick & John Fitzgerald)

1999

Evaluation of DEP’sPrivatized Program

“Critical ExposurePathway” RegulationsImplemented

Revision ofGW-2 Stnds(Proposed)

Page 3: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Timeline for MADEP Concerns with the Groundwater/Indoor Air Pathway

19891992

19931996

19982000

2001

Hillside School(Microwave Development Lab Site)

Revision of State Waste SiteCleanup Regulations (MCP)(Introduces a Privatized Program)

DEP Regional StaffEvaluate Vapor Intrusion Pathway(Nancy Fitzpatrick & John Fitzgerald)

1999

Evaluation of DEP’sPrivatized Program

“Critical ExposurePathway” RegulationsImplemented

Revision ofGW-2 Stnds(Proposed)

Page 4: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Key Features of the Massachusetts Contingency Plan

• Privatized process: Licensed Site Professional (LSP) oversees work

• Remediation to level of “No Significant Risk” or “Background” (where feasible)

• Audit program reviews X % of work

Page 5: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Risk Characterization in theMassachusetts Contingency Plan

(310 CMR 40.0900)

3 Options to Assess Risk:– Generic Soil and Groundwater Standards (Method 1),

3 categories eachRisk Limits: Chemical Specific Risk Levels of 1 x 10-6

(cancer), Hazard Index = 0.2

– Modification of Method 1 Standards (Method 2)

– Site-specific Risk Assessment (Method 3)Risk Limits: Cumulative Cancer Risk = 1 x 10-5, Cumulative

Noncancer Risk = HI = 1

Page 6: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Groundwater Standards•GW-1: current or future drinking water source

•GW-2: source of indoor air contamination“Groundwater shall be defined to be in category GW-2 if it is located within 30 feet of an existing occupied building or structure, and the average annual depth to groundwater in that area is 15 feet or less. Category GW-2 groundwater is considered to be a potential source of vapors of oil and/or hazardous material to indoor air.” (310 CMR 40.0932(6))

•GW-3: source of surface water contamination

Page 7: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

GW-2: Groundwater -> Indoor AirNoncancerRisk-basedIndoor Air

Concentration

Cancer Risk-basedIndoor Air

Concentration

50% Odor RecognitionThreshold

Lowest ofThese 3

Indoor AirBackground

Higher of theseas Target Indoor

Air Target Concentration

airgroundwater

Model(Johnson & Ettinger)

Calculated SourceConcentration in Groundwater

Ceiling Concentration

Lower of These 2

GroundwaterBackground

PracticalQuantitation

Limit

Highest of These 3Concentrations Adoptedas MCP GW-2 Standard

Page 8: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

GW-2 Derivation

• Noncancer risk-based concentration:[OHM]air = 0.2 x RfC

• Cancer risk-bsaed concentration:[OHM]air = 10-6/URair

• Attenuation Factor, = 5 x 10-4, applied to all chemicals with an additional adjustment factor, d, applied by DEP:

[OHM]gw = [OHM]air / ( x d x H x C)

Page 9: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Timeline for MADEP Concerns with the Groundwater/Indoor Air Pathway

19891992

19931996

19982000

2001

Hillside School(Microwave Development Lab Site)

Revision of State Waste SiteCleanup Regulations (MCP)(Introduces a Privatized Program)

DEP Regional StaffEvaluate Vapor Intrusion Pathway(Nancy Fitzpatrick & John Fitzgerald)

1999

Evaluation of DEP’sPrivatized Program

“Critical ExposurePathway” RegulationsImplemented

Revision ofGW-2 Stnds(Proposed)

Page 10: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

1998 Evaluation of MCPProgram is generally working, but there are areas to

be addressed

Among conclusions:• GW-2 Standards may not be sufficiently protective in some

cases• Focus on current buildings may not be sufficiently protective• Uncertainty/variability in pathway calls for alternative

approach• Soil -> Indoor Air pathway often overlooked

Page 11: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

DEP IntroducesCritical Exposure Pathways

(310 CMR 40.0006 & 40.0414)

…[R]outes by which OHM(s)…are transported, or likely to be transported, to human receptors via:(a) vapor-phase emissions…in the living or working space of a pre-school, daycare, school or occupied residential dwelling; or(b) ingestion, dermal absorption or inhalation …from drinking water supply wells located at and servicing a pre-school, daycare, school or occupied residential dwelling.

Page 12: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Concept (simplified):• “Substantial Release Migration” (impacts to indoor

air/water supply within 1 year) requires notification to DEP

• “Immediate Response Action” (IRA) is implemented to contain/remove OHM

• All IRA’s must eliminate, mitigate or prevent Critical Exposure Pathways, where feasible…regardless of risk posed.

Page 13: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

FY2001 Revisions to Standards

• All Numerical Standards, not just GW-2, under revision

• GW-2 evaluation to include chemical-specific modeling of vapor intrusion using USEPA Johnson & Ettinger model spreadsheets.

• Regulations also to include trigger levels of VOCs in soil to address applicability of Method 1 soil standards.

Page 14: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

GW-2: Driving Force for Remediation?• Current Standards

– GW-2 is lowest standard (of GW-1, GW-2 and GW-3) for 5 of 112 chemicals

– In non-drinking water areas, GW-2 is the lower (of GW-2 and GW-3) standard for 32 of 112 chemicals

• FY 2001 Revisions– GW-2 may be lowest standard (of GW-1, GW-2 and

GW-3) for 20 of 116 chemicals– In non-drinking water areas, GW-2 may be the lower (of GW-

2 & GW-3) standard for 57 of 116 chemicals

Page 15: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

What we’ve learned…

• Majority of documented vapor intrusion cases related to “classic” chlorinated VOC plumes

• Vapor intrusion associated with non-chlorinated VOCs primarily observed at sites with NAPL and/or vapor migration along preferential pathways (i.e.,utility lines, faulty plumbing)

Page 16: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Site Characteristics

• Shallow water tables• Significant [VOCs] in groundwater

and/or soil gas• Permeable soil• Proximity to source• Presence of non-permeable surfaces

between source and receptor

Page 17: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Fresh Water Lens Phenomenon

• Large, unpaved areas between source & receptor (ofetn at base of slope) that allow infiltration of precipitation

• Creates lens of “clean” water in upper portion of water table

• Increases distance for liquid-phase diffusion & limits transport to air phase

Page 18: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Building Characteristics

• Basements • Earthen Floors• Fieldstone foundations, multiple cracks,

sumps• Negative pressure “stack effects”

induced by heating systems; “worst case” winter months

Page 19: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Stoughton, MA

• Residential homes with basements• Very shallow water table• 580 ug/l 1,1,1-TCA measured in sump

water (GW-2 Standard 4,000 ug/l) • Imminent Hazard levels of chlorinated

VOCs measured in indoor air• Various venting systems installed

Page 20: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Burlington, MA

• Residential homes with basements• Relatively shallow water table• Gasoline plume > GW-2 Standards• Significant [BTEX] measured in soil gas

adjacent to sewer lines connecting to homes

• Gasoline odors in home, faulty plumbing

Page 21: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

North Adams, MA

• Residential homes, most with earthen floors and/or fieldstone foundations

• SRM investigation of TCE plume emanating from old landfill

• Water table 7-13 feet bsg, coarse sand• Synoptic gw, soil gas, indoor air data

collected prior to venting systems

Page 22: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

TCE Data - North Adams, MA

• June 1997– 350 ug/l in groundwater– 11,000 ug/m3 in soil gas (HC = 0.004)

• Home #6 (dirt floor, wet) – 330 ug/m3 in indoor air (AC = 3E-2)

• Home #7 (cement floor & walls, sump)– 13.44 ug/m3 in indoor air (AC = 1.2E-3)

Page 23: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

GW to SG Partitioning Data

• 2,000 - 2,300 ug/l TCE in groundwater• 52,000 - 170,000 ug/m3 in soil gas

– Hc partitioning range 0.026 - 0.074• 120 ug/l TCE in groundwater• 53,000 ug/m3 in soil gas

– Hc partitioning = 0.44

Page 24: Learning from the States… Commonwealth of Massachusetts

of Massachusetts Department

ENVIRONMENTAL PROTECTION

Indoor Air/Soil Gas ACs

• Home #5 (dirt floor, water)– 8,800 ug/m3 in soil gas (Dec 1996)– 140 ug/m3 in indoor air (Jan 1997)– AC = 1.6E-2

• Home #16 (concrete floor?)– 15,000 ug/m3 in soil gas (Oct 1997)– 6 ug/m3 in indoor air (Nov 1997)– AC = 4E-4