EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems Original assembly instructions acc. to EC Dir. 2006/42/EC for partly completed machinery with associated operating instructions Version 03 Schmierung starten Start lubrication Fehler Fault 1 2 3

Transcript of LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in...

Page 1: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

ENLC502 control cubicle for use in

ProFlex/MonoFlex/DuoFlex centralized lubrication systems

Original assembly instructions acc. to EC Dir. 2006/42/EC for partly completed machinery with associated operating instructions

Version 03

Schmierung starten

Start lubrication

FehlerFault

1

2

3

Page 2: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 2 EN

LC502 control cubicle

Notes

Masthead

These original assembly instructions with

associated operating instructions in accordance

with EC Machinery Directive 2006/42/EC are

an integral part of the described product and

must be kept for future use.

These original assembly instructions with as-

sociated operating instructions were compiled

in accordance with the established standards

and rules for technical documentation,

VDI 4500 and EN 292.

© SKF Lubrication Systems Germany GmbH

This documentation is protected by copyright.

SKF Lubrication Systems Germany GmbH re-

serves all rights, including those to the photo-

mechanical reproduction, duplication, and distri-

bution by means of special procedures (e.g., data

processing, data media, and data networks) of

this documentation in whole or in part.

Subject to changes in contents and technical

information.

Service

If you have technical questions, please contact

the following addresses:

SKF Lubrication Systems Germany GmbH

Berlin Plant

Motzener Strasse 35/37

12277 Berlin

Germany

Tel. +49 (0)30 72002-0

Fax +49 (0)30 72002-111

www.skf.com/lubrication

Hockenheim Plant

2. Industriestrasse 4

68766 Hockenheim

Germany

Tel. +49 (0)62 05 27-0

Fax +49 (0)62 05 27-101

www.skf.com/lubrication

Danger!Electrical voltage/current

The door (1) of the LC502 control

cubicle (2) must be opened only when

the basic switch is switched off (3,

position "OFF"). The basic switch (3)

must remain switched off until all

work of any kind on the control cu-

bicle is completed. The basic switch (3)

must not be switched on again even

temporarily while work is carried out.

Schmierung starten

Start lubrication

FehlerFault

1

2

3

OFF

1

2

3

Page 3: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 3 EN

Table of contents

Assembly instructions

Information concerning EC Declaration of Conformity and EC Declaration of Incorporation 4

1. Safety instructions 6

1.1 Intended use 6

1.2 Authorized personnel 6

1.3 Electric shock hazard 7

1.4 System pressure hazard 7

1.5 Assembly work 7

2. Lubricants 8

2.1 General information 8

2.2 Selection of lubricants 8

2.3 Approved lubricants 9

2.4 Lubricants and the environment 9

2.5 Lubricant hazards 10

3. Overview 10

4. Assembly 11

4.1 Setup and attachment 11

4.1.1 Installing the LC502 control cubicle 12

4.2 Connection dimensions, minimum installation dimensions 13

4.2.1 Assembly drawing for LC502 control cubicle 13

4.2 Electrical connection 14

4.2.1 General information 14

4.2.2 Control cubicle (standard design) 15

4.3 Terminal block X1, power supply 16

4.3.1 Power supply 24 VDC 16

4.3.2 Power supply 230 VAC 16

4.3.3 Power supply 400 VAC 3-phase 16

4.3.4 Connection of motor circuit breaker (230VAC/400 VAC 3-phase) 17

4.3.5 Setting the mode of operation on the motor circuit breaker (230 VAC/400 VAC 3-phase) 17

4.4 Assignment of terminal block X2, inputs 18

4.4.1 DuoFlex centralized lubrication system, terminal block X2, assignment of the inputs with analog pressure sensors 18

4.4.2 DuoFlex centralized lubrication system, terminal block X2, assignment of inputs with DDS50/1 20

4.4.3 ProFlex centralized lubrication system, terminal block X2, assignment of

the inputs 22

4.4.4 MonoFlex centralized lubrication system, terminal block X2, assignment of the

inputs with pressure switches 24

4.4.5 MonoFlex centralized lubrication system, terminal block X2, assignment of the

inputs with analog pressure sensors 26

4.5 Assignment of terminal block X3, outputs 28

4.5.1 Terminal block X3, outputs, 24 VDC 28

4.5.2 DuoFlex centralized lubrication system, terminal block X3, outputs, 230/400 VAC 3-phase 28

4.6 Finishing assembly work 29

4.7 Note on the rating plate 29

Instructions associated

1. Safety instructions 32

2. Lubricants 32

3. Transport, delivery, and storage 33

3.1 Lubrication units 33

3.2 Electronic and electrical devices 33

3.3 General notes 33

4. Assembly 34

4.1 Information on assembly 34

5. Design and function 34

5.1 General information 34

6. Control and display elements 34

6.1. Display and control elements of the control screen 35

7. Commissioning 37

7.1 Setting parameters of the LC502 control unit 37

8. Shutdown and disposal 38

8.1 Temporary shutdown 38

9. Maintenance 39

9.1 General information 39

9.2 Changing defective fuses (230/400 VAC 3-phase type only) 40

10. Malfunctions 41

10.1 Program malfunctions, LC502 41

10.2 Commissioning malfunctions 42

10.3 Operational malfunctions. 43

11. Technical data 44

12. Spare parts 44

Table of contents

Page 4: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 4 EN

EC Declaration of Incorporation according to Machinery Directive 2006/42/EC, Annex II Part 1 B

The manufacturer SKF Lubrication Systems Germany GmbH, plant Hockenheim, 2. Industriestraße 4, DE - 68766 Hockenheim, hereby declares that the partly completed machinery:

Designation: control cubicle Type: LC502

Part no.:

24 V DC 230 VAC 400 VDuoFlex 24-1074-2260 24-1074-2230 24-1074-2200

MonoFlex 24-1074-2270 24-1074-2240 24-1074-2210ProFlex 24-1074-2280 24-1074-2250 24-1074-2220

Year of construction: See type identification plate

complies with the following basic requirements of the EC Machinery Directive 2006/42/EC at the time when first being launched in the market.

1.1.2 · 1.1.3 · 1.3.1 · 1.3.2 · 1.3.4 · 1.5.1 · 1.5.2 · 1.5.6· 1.5.8 · 1.6.1 · 1.6.2 · 1.6.3 · 1.6.4 · 1.7.1 · 1.7.2 · 1.7.3 · 1.7.4

The special technical documents were prepared following annex II part B of this directive. Upon justifiable request, these special technical documents can be forwarded electronically to the respective national authorities. The person empowered to assemble the technical documentation on behalf of the manufacturer is the head of standardization; see manufacturer‘s address. Furthermore, the following directives and harmonized standards were applied in the respective applicable areas:

2011/65/EU RoHS II 2014/30/EU Electromagnetic compatibility | Industry

Standard Edition Standard Edition Standard Edition Standard EditionDIN EN ISO 12100 2011 DIN EN 60947-5-1 2010 DIN EN 61000-6-2 2006 DIN EN 61000-6-4 2011DIN EN 50581 2013 DIN EN 61000-6-1 2007 Amendment 2011 DIN EN 60947-5-1 2010DIN EN 60204-1 2007 DIN EN 61000-6-3 2011 DIN EN 61439 2012Amendment 2010 Amendment 2012

The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of the EC Machinery Directive 2006/42/EC and any other applicable directives.

Hockenheim, 2017.10.13

Jürgen Kreutzkämper Manager R&D GermanySKF Lubrication Business Unit

Stefan Schürmann Manager R&D Hockenheim/Walldorf SKF Lubrication Business Unit

Page 5: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 5 EN

Informational symbolsIndicators used with safety instructions

and their signiicance

Hazard symbols

Explanation of symbols

Explanation of symbols and signs

You will ind these symbols, which warn of

speciic dangers to persons, material assets, or

the environment, next to all safety instructions

in these operating instructions.

Please heed these instructions and proceed

with special care in such cases. Please forward

all safety instructions to other users.

General hazard DIN 4844-2-W000

Electrical voltage/current

Hot surface

Signal word Meaning

Danger! Danger of bodily injury

Warning! Danger of damage to property and the environment

Note! Provides additional informa- tion

Note!

Prompts an action

Used for itemizing

Points out other facts, causes, or consequences Provides additional information

Instructions placed directly on the machines/

grease lubrication pump units, such as:

Rotation arrow

Labels for luid connections

must be followed and kept in fully legible

condition.

You are responsible!

Please read the assembly and operating

instructions thoroughly and follow the safety

instructions.

Danger of being drawn into machinery

DIN 4844-2-W008

DIN 4844-2-W026

BGV 8A

Slipping hazardDIN 4844-2-W028

Environmentally friendly disposal

Page 6: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 6 EN Assembly instructions

1. Safety instructions

The operator of the described product

must ensure that the assembly instruc-

tions are read and understood by all

persons tasked with the assembly,

operation, maintenance, and repair of

the product. The assembly instructions

must be kept readily available.

Note that the assembly instructions

form part of the product and must

accompany the product if sold to a new

owner.

In addition to the assembly instructions,

statutory regulations and other general

regulations for accident prevention

and environmental protection must be

observed and applied.

1.2 Authorized personnel

Only qualified technical personnel may install,

operate, maintain, and repair the LC502 con-

trol cubicle described in the assembly instruc-

tions. Qualified technical personnel are per-

sons who have been trained, assigned and

instructed by the operator of the final product

into which the described product is incorpo-

rated. Such persons are familiar with the rel-

evant standards, rules, accident prevention

regulations, and assembly conditions as a re-

sult of their training, experience, and instruc-

tion. They are authorized to identify and per-

form necessary actions while avoiding any

risks which may arise.

The definition of qualified personnel and the

prohibition against employing non-qualified

personnel are laid down in DIN VDE 0105 and

IEC 364.

The described product is manufactured in ac-

cordance with the generally accepted rules and

standards of industry practice and with occu-

pational safety and accident prevention regu-

lations. Risks may, however, arise from its us-

age and may result in physical harm to

persons or damage to other material assets.

Therefore the product may only be used in

proper technical condition and in observance

of the assembly instructions. In particular, any

malfunctions which may affect safety must be

remedied immediately.

1.1 Intended use

The LC502 control cubicle and the compo-

nents integrated in it are designed for the

control and monitoring of an SKF ProFlex,

MonoFlex or DuoFlex centralized lubrication

system.

Any other usage is deemed non-compliant

with the intended use.

The control cubicle is referred to in the follow-

ing document as the LC502 control cubicle or

as the product.

Page 7: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 7 ENAssembly instructions

1.4 System pressure hazard

Lubrication systems are pressurized

during operation. Centralized lubri-

cation systems must therefore be

depressurized before starting assembly,

maintenance or repair work, or any

system modiications or system repairs.

1.3 Electric shock hazard

Electrical connections for the described prod-

uct may only be established by qualified and

trained personnel authorized to do so by the

operator, and in observance of the local condi-

tions for connections and local regulations

(e.g., DIN, VDE). Significant bodily injury and

property damage may result from improperly

connected products.

Danger!

Performing work on an energized

pump or product may result in serious

injury or death.

Assembly, maintenance and repair work

may only be performed on products

that have been de-energized by

qualiied technical personnel. The

supply voltage must be switched off

(at the basic switch, see page 2, Fig. 1)

before opening any of the product's

components.

1.5 Assembly work

Work on electrical control cubicles and their

components should only ever be carried out

when the power supply is disconnected. Be sure

to follow the procedure for turning off the

electrical switchgear prescribed in the operat-

ing instructions for the centralized lubrication

system. When performing any assembly work

on the electrical control cubicle and its com-

ponents, the local accident prevention regula-

tions as well as the specific operation and

maintenance specifications are to be followed.

Page 8: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 8 EN Assembly instructions

2. Lubricants

2.1 General information

All products from SKF Lubrication

Systems Germany GmbH may be used

only for their intended purpose and in

accordance with the information in the

product's assembly instructions.

Intended use is the use of the products for the

purpose of providing centralized lubrication/

lubrication of bearings and friction points

using lubricants within the physical usage li-

mits which can be found in the documentation

for the devices, e.g., assembly instructions/

operating instructions and the product de-

scriptions, e.g., technical drawings and cata-

logs.

Hazardous materials of any kind, especially

the materials classified as hazardous by CLP

Regulation EC 1272/2008 may only be used

to fill SKF centralized lubrication systems and

components and deliv-ered and/or distributed

with the same after consulting with and recei-

ving written approval from SKF.

No products manufactured by SKF Lubrication

Systems Germany GmbH are approved for

use in conjunction with gases, liquefied gases,

pressurized gases in solution, vapors, or such

fluids whose vapor pressure exceeds normal

atmospheric pressure (1013 mbar) by more

than 0.5 bar at their maximum permissible

temperature.

Other media which are neither lubricant nor

hazardous substance may only be fed after

consultation with and written approval from

SKF Lubrication Systems Germany GmbH .

SKF Lubrication Systems Germany GmbH

considers lubricants to be a component of the

system design which must be factored into the

selection of components and the design of

centralized lubrication systems. The lubricating

properties of the lubricants are critically im-

portant in these considerations.

2.2 Selection of lubricants

Observe the instructions from the

machine manufacturer regarding the

lubricants that are to be used.

Warning!

The amount of lubricant required at

a lubrication point is speciied by the

bearing or machine manufacturer. It

must be ensured that the required

quantity of lubricant is provided to the

lubrication point. The lubrication point

may otherwise not receive adequate

lubrication, which can lead to damage

and failure of the bearing.

The selection of a lubricant suitable for

the lubrication task is made by the machine/

system manufacturer and/or the operator of

the machine/system in cooperation with the

lubricant supplier.

The bearings/friction points that require lubri-

cation, their expected load during operation,

and the expected ambient conditions are taken

into account during selection, with consider-

ation of economic and environmental aspects.

Page 9: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 9 ENAssembly instructions

2.4 Lubricants and the environment

Lubricants can contaminate soil and

bodies of water. Lubricants must be

properly used and disposed of. Observe

the local regulations and laws regarding

the disposal of lubricants.

It is important to note that lubricants are envi-

ronmentally hazardous, flammable substances

which require special precautionary measures

during transport, storage, and processing.

Consult the safety data sheet from the lubri-

cant manufacturer for information regarding

transport, storage, processing, and environ-

mental hazards of the lubricant that will be

used.

The safety data sheet for a lubricant can be

requested from the lubricant manufacturer.

SKF Lubrication Systems Germany

GmbH supports customers

in the selection of suitable components

for feeding the selected lubricant and in

the planning and design of a centralized

lubrication system.

Please contact SKF Lubrication Systems

Germany GmbH if you have further questions

regarding lubricants. Lubricants can be tested

in the company's laboratory for their suitability

for pumping in centralized lubrication systems

(e.g., "bleeding").

You can request an overview of the lubricant

tests offered by SKF Lubrication Systems

Germany GmbH from the company's Service

department.

2.3 Approved lubricants

Only lubricants approved for the prod-

uct may be used. Unsuitable lubricants

can lead to failure of the product and to

property damage.

Different lubricants cannot be mixed, as

mixing may result in damage and ne-

cessitate costly and complicated clean-

ing of the product/lubrication system.

It is recommended that an indication of

the lubricant in use be attached to the

lubricant reservoir in order to prevent

accidental mixing of lubricants.

The product described here can be operated

using lubricants that meet the specifications in

the technical data. Depending on the product

design, these lubricants may be oils, fluid

greases, or greases.

Oils and base oils may be mineral, synthetic,

and/or rapidly biodegradable. Consistency

agents and additives may be added depending

on the operating conditions.

Note that in rare cases, there may be lubri-

cants whose properties are within permissible

limit values but whose other characteristics

render them unsuitable for use in centralized

lubrication systems. For example, synthetic lu-

bricants may be incompatible with elastomers.

Page 10: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Display and controls, Fig. 1

Page 10 EN Assembly instructions

3. Overview

Display and controls

Item Description

1 LC502 control cubicle

2 Basic switch

3 LC502 control display

4 Red fault indicator light

5 "Start control" button (230/400 VAC type only

Schmierung starten

Start lubrication

FehlerFault

1

2

3

1

3

2

4 5

2.5 Lubricant hazards

Centralized lubrication systems must

always be free of leaks. Leaking lu-

bricant is hazardous due to the risk of

slipping and injury. Be mindful of any

lubricant leaking out during assembly,

operation, maintenance, and repair of

centralized lubrication systems. Leaks

must be sealed off without delay.

Lubricant leaking from centralized lubrication

systems is a serious hazard. Leaking lubricant

can create risks that may result in physical

harm to persons or damage to other material

assets.

Follow the safety instructions on the

lubricant's safety data sheet.

Lubricants are a hazardous substance. The

safety instructions on the lubricant's safety

data sheet must be strictly followed. The safety

data sheet for a lubricant can be requested

from the lubricant manufacturer.

Page 11: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 11 ENAssembly instructions

4. Assembly

4.1 Setup and attachment

The product should be protected from humid-

ity and vibration, and should be mounted so

that it is easily accessible, allowing all further

installation work to be done without difficulty.

Make sure there is adequate air circulation to

prevent the product from overheating. For the

maximum permissible ambient temperature,

see "Technical data."

The product is mounted in a vertical position.

The LC502 control cubicle is supplied either as

a separate product or already connected to the

pump unit.

The following points must be observed for

both versions:

During assembly and especially when drilling,

always pay attention to the following:

Existing supply lines must not be dam-

aged by assembly work.

Other units must not be damaged by as-

sembly work.

The product must not be installed within

range of moving parts.

The product must be installed at an ad-

equate distance from sources of heat.

Maintain safety clearances and comply

with local regulations for assembly and

accident prevention.

Ensure the display is easily visible

Ensure there is enough space to open the

control cubicle door

Page 12: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 12 EN Assembly instructions

The LC502 control cubicle is installed either

with 4 socket-head screws (with washers) or

with an external wall mount, SKF order No.

24-0850-2010.

If the unit is to be fastened using M8 thread

holes, the screws must have a minimum

length of 15 mm.

Fastening material to be provided by the

customer:

Socket-head screws (4x) to

DIN 912-M8x-8.8

Washers (4x) to DIN 125-B10.5-St

Hexagon nuts M8 (4x) to DIN 934

Drill assembly holes (or thread M8) accord-

ing to the assembly drawing (Fig. 3) and

the conditions on the surface.

Clean surface to remove drilling chips.

Open the LC502 control cubicle, place it on

the installation surface, and roughly align it

Guide the socket-head screws (4x) (size 6

mm) with their washers (4x) through the

fastener holes on the cubicle inside wall and

bring into contact with the M8 thread/nut

of the installation surface.

Gently tighten the socket-head screws,

and align the LC502 control cubicle

Tighten the socket-head screws (size

6 mm) to following torque:

Torque 25 Nm

4.1.1 Installing the LC502 control cubicle

(separate product)

See following page, Figure 2

The LC502 control cubicle must be installed

on a level surface. The flanging surface must

not be under stress. During installation, be

sure to comply with the minimum installation

dimensions (sufficient clearance) for later service

and maintenance work (see following page).

Warning!

When drilling the assembly holes, you

must be careful of any supply lines or

other units, as well as of other hazards

such as moving parts.

Maintain safety clearances and comply

with local regulations for assembly and

accident prevention.

Warning!

Do not tilt or drop the LC502 control

cubicle.

Page 13: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 13 ENAssembly instructions

300

300

2

3

1

210

ca. 2

20ca

. 330

ca. 340

Schmierung starten

Start lubrication

FehlerFault

26026

0

Ø 8

2020

Connection dimensions, minimum installation dimensions, Fig. 2

4.2 Connection dimensions, minimum installation dimensions

4.2.1 Assembly drawing for LC502 control cubicle

Power supply to control cabinetPower supply to pump motorInput 4 (LC502 control)Input 3 (LC502 control)Input 2 (LC502 control)Input 1 (LC502 control)Fault outputOutput 2 (LC502 control)Output 1 (LC502 control)

Dimension for outer edge of control cubicle

Clearance/minimum installation dimensions

Dimension Min. installation dimension [mm]Width 400Height 400Depth 600

Page 14: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Basic switch, Fig. 3

Page 14 EN Assembly instructions

4.2 Electrical connection

4.2.1 General information

The LC502 control cubicle is designed for a

power supply (input voltage) of 230 VAC or

400 VAC 3-phase. The LC502 control cubicle

is supplied either as a separate unit or already

connected to an SKF pump unit.

The LC502 control cubicle is supplied either as

a separate unit or already connected to an

SKF pump unit. How the control cubicle is in-

tegrated into a lubrication system depends on

the customer's specific application, as does the

configuration of the technical ratings and

characteristics. Responsibility and liability for

these matters lies with the customer or the

system manufacturer.

Danger!

Electrical connections for the LC502

control cubicle may only be established

by qualiied and trained personnel au-

thorized to do so by the operator, and

in observance of the local conditions

for connections and local regulations

(e.g., DIN, VDE). Signiicant bodily injury

and property damage may result from

improperly connected products.

Danger!

The available mains voltage

(supply voltage) must be in accordance

with the speciications on the rating

plate of the motor or of the electrical

components. Check the fuse protection

of the electrical circuit. Use only fuses

with the prescribed amperage, else

bodily injury and property damage may

result.

Consult the rating plate or technical documen-

tation of the motor to be connected for the

electrical characteristics of the motor, such as

rated voltage, rated frequency, and rated

current.

Danger!

Electrical voltage/current

The power supply to the LC502 control

cubicle (1) must be connected only

when the basic switch is switched off

(2, position "OFF"). Other work on the

control cubicle must always be car-

ried out by qualiied technical person-

nel. The basic switch (2) must not be

switched on again even temporarily

while work is carried out.

Schmierung starten

Start lubrication

FehlerFault

1

2

3

OFF

1

2

3

Page 15: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Positioning of connections for control cubicle, types with 24 VDC, 230 VAC, 400 VAC 3-phase, Fig. 4

X 2

X 3

X 1

1 2 3

4 5 6

PEPE

5 6

1 2 3

4

1 2 PE 3 4 PE PE

24

9 10 1112

2322212019181716151413

1 2 3 4 5 6 7 8

242322212019181716151413

9 10 11121 2 3 4 5 6 7 8

PE PE

8-K

4

8-K1M6-Q2

6-F

1

6-Q1

X 2

X 1

X 3

24

9 10 1112

2322212019181716151413

1 2 3 4

5 6 7 8

PE PE

5 6 7 8

1 2 3 4

1 2 3 4 5 6 7 8

242322212019181716151413

9 10 11121 2 3 4 5 6 7 8

L1 L2 L3 N PE U V WPE PE

PE PE

6-K

2

8-K

4

8-K1M

6-Q2

6-T1 6-F

16

-F2

6-Q1

X 2

X 1

X 3

24

9 10 1112

2322212019181716151413

1 2 3 4

5 6 7 8

PE PE

5 6 7 8

1 2 3 4

1 2 3 4 5 6 7 8

242322212019181716151413

9 10 11121 2 3 4 5 6 7 8

L1 N PE 1 2 PE PE

PE PE

6-K

2

8-K

4

8-K1M

6-Q2

6-T1 6-F

16

-F2

6-Q1

24 VDC 230 VAC 400 VAC

X2

X1

X3

Page 15 ENAssembly instructions

4.2.2 Control cubicle (standard design)

Guide individual cable harnesses as shown on Fig. 2 through the cable glands (conduit thread screw unions) (Fig. 3, item 3)

Page 16: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

400 VAC 3-phase 24 VDC

Assignment of terminal block X1, 400 VAC

L1 Power supply (L1)L2 Power supply (L2)L3 Power supply (L3)N Power supply (N)PE Protective (earth) conductorL1 Motor (L1)L2 Motor (L2)L3 Motor (L3)PE Protective (earth) conductorPE Protective (earth) conductor

Assignment of terminal block X1, 24 VDC

1 Power supply (+)2 Power supply (-)PE Protective (earth) conductor3 Motor (+)4 Motor (-)PE Protective (earth) conductorPE Protective (earth) conductor

Cabletype Cabletype

Term

inal

blo

ck: X

1

Aim

1

Terminal-No. Bridge

BMK

Connector

Position

Feed in Power supply

3G2,5 3G2,5

1 2 grge

1 2 grge

Fee

d in

Fee

d in

Fee

d in

Mot

or M

otor

Mot

or

Cus

tom

er C

usto

mer

Cus

tom

er 6

-M1

6-M

1 6

-M1

+ - PE

1 2 PE 3 4 PE PE

PE+ -

230 VAC

Assignment of terminal block X1, 230 VAC

L1 Power supply (L1)N Power supply (N)PE Protective (earth) conductorL1 Motor (L1)N Motor (N)PE Protective (earth) conductorPE Protective (earth) conductor

Cabletype CabletypeTe

rmin

al b

lock

: X1

Aim

1

Terminal-No. Bridge

BMK

Connector

Position

Feed in Power supply

3G2,5 3G1,5

sw bl grge

1 2 grge

Fee

d in

Fee

d in

Fee

d in

Mot

or M

otor

Mot

or

Cus

tom

er C

usto

mer

Cus

tom

er 6

-M1

6-M

1 6

-M1

PE

L1 N PE 1 2 PE PE

L1 N PE L1 N

Cabletype Cabletype

Term

inal

blo

ck: X

1

Aim

1

Terminal-No. Bridge

BMK

Connector

Position

Feed in Power supply

5G2,5 4G1,5

sw br sw bl grge

1 2 3 grge

fee

d in

fee

d in

fee

d in

fee

d in

fee

d in

Mot

or M

otor

Mot

or M

otor

Cus

tom

er C

usto

mer

Cus

tom

er C

usto

mer

Kun

de 6

-M1

6-M

1 6

-M1

6-M

1

U V W PE

L1 L2 L3 N PE U V W PE PE

L1 L2 L3 N PE

Page 16 EN Assembly instructions

4.3.1 Power supply 24 VDC 4.3.2 Power supply 230 VAC 4.3.3 Power supply 400 VAC 3-phase

4.3 Terminal block X1, power supply

Page 17: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Settings on the motor circuit breaker, Fig. 5

Page 17 ENAssembly instructions

4.3.4 Connection of motor circuit breaker

(230VAC/400 VAC 3-phase)

The motor circuit breaker is integrated

in the LC502 control cubicle only in the

230 VAC and 400 VAC 3-phase types.

Consult the rating plate or technical docu-

mentation of the motor to be connected for

the electrical characteristics of the motor,

such as rated current.

Determine the maximum permissible

rated current of the pump unit to be

connected

Set the rated current value according to

the rated current specified for the pump

motor on the dial of the thumb wheel

On the thumb wheel (1) on the motor cir

cuit breaker (2), set the maximum permis-

sible rated current value (from the pump

motor).

Check the functioning of the motor circuit

breaker using the test button (4)

1

2

4.3.5 Setting the mode of operation on the

motor circuit breaker

(230 VAC/400 VAC 3-phase)

The protection mode of the motor circuit

breaker (automatic/manual) must be set by

the customer. It is set using the

thumb wheel (3) on the motor circuit

breaker.

Set the mode of operation by turning

the thumb wheel (3) to one of these

two positions on the wheel (3):

Position A = automatic

Position H = manual

3

4

Page 18: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 18 EN Assembly instructions

4.4.1 DuoFlex centralized lubrication system, terminal block X2, assignment of the

inputs with analog pressure sensors

4.4 Assignment of terminal block X2,

inputs

The assignment of the inputs and outputs

varies depending on the lubrication system in

use.

This may be:

DuoFlex for a dual-line

centralized lubrication system with analog

pressure sensors (Chapter 4.4.1)

DuoFlex for a dual-line

centralized lubrication system with differen-

tial-pressure switch DDS50/1

(Chapter 4.4.2)

ProFlex for a progressive

centralized lubrication system

(Chapter 4.4.3)

MonoFlex for a single-line

centralized lubrication system with pressure

switches (Chapter 4.4.4)

MonoFlex for a single-line

centralized lubrication system with analog

pressure sensors (Chapter 4.4.5)

2-wire switch • Switches, buttons, etc. (machine contact) • Cycle switch (2-wire cycle switch only) 177-300-091, -092, -096 • Pressure switch • Differential-pressure switch (requires 2 inputs) • Mech. fill level switch (FF and FB pumps) 3-wire switch • Ultrasonic fill level switch • W2 fill level control (capacitive proximity switch) Analog sensor • Pressure sensor • Analog fill level switch *) When analog sensors are used, a BES6 plug-in jumper (fitted with a 1.0 kΩ, 0.5W resistor) must be inserted between "Signal (-)" and "Power supply (-)" in order to adapt the measurement range.

Terminal diagram X2, 24 VDC/230 V AC/400 VAC

Terminal block X2

Input No. Function 2-wire switch

3-wire switch

Analog sensor

Input

1

1 Not connected

2 Pressure sensor 1 (+24V) X

3 Not connected

13 Pressure sensor 1 (signal) X | *)

14 Pressure sensor 1 (0V) X | *)

15 Not connected

Input

2

4 Not connected

5 Pressure sensor 2 (+24V) X

6 Not connected

16 Pressure sensor (signal) X | *)

17 Pressure sensor 2 (0V) X | *)

18 Not connected

Input

3

7 Delay extension (+) X

8 Not connected

9 Delay extension (-) X

19 Not connected

20 Not connected

21 Not connected

Input

4

10 Not connected

11 Fill level (+24V) X

12 Not connected

22 Fill level (signal) X

23 Fill level (0V) X

24 Not connected

Page 19: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 19 ENAssembly instructions

DuoFlex centralized lubrication system, terminal block X2, inputs with analog pressure sensors

Cabletype Cabletype

Term

inal

blo

ck: X

2

Aim

1

Terminal-No.

Bridge

BMK

Connector

Position

1 2 3 4 5 6 7 8 9 10 11 12 PE PE 13 14 15 16 17 18 19 20 21 22 23 24 PE PE

Pressure sensor, line 1 Pressure sensor, line 2 Delay extension Fill level

3X0,75 3X0,75 2X0,75 3X0,75

1 2 3

1 2 3

1kΩ 1kΩ

1 2

+ D

elay

ext

ensi

on

- D

elay

ext

ensi

on

Cus

tom

er

Cus

tom

er

+ -

+24

V F

ill le

ve

Sig

nal F

ill le

vel

OV F

ill le

vel

1 2 3

Fill

leve

1 2 3 F

ill le

vel

Fill

leve

l

1 341 34

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 2

Pre

ssur

e, li

ne 2

Pre

ssur

e, li

ne 2

Pre

ssu

re s

en

sor

1

Pre

ssu

re s

en

sor 1

Pre

ssu

re s

en

sor

1

Pre

ssu

re s

en

sor

2

Pre

ssu

re s

en

sor

2 P

ress

ure

se

nso

r 2

DuoFlex centralized lubrication system, terminal diagram X2, assignment of the inputs with analog pressure sensors

Page 20: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Terminal diagram X2, 24 VDC/230 VAC/400 VAC

Terminal block X2 (400V, 230V, 24V)

Input No. Function 2-wire switch

3-wire switch

Analog sensor

Input 1 1 Differential-pressure switch (1) X

2 Not connected

3 Differential-pressure switch (2) X

13 Not connected

14 Not connected

15 Not connected

Input 2 4 Differential-pressure switch (3) X

5 Not connected

6 Differential-pressure switch (4) X

16 Not connected

17 Not connected

18 Not connected

Input 3 7 Delay extension (+) X

8 Not connected

9 Delay extension (-) X

19 Not connected

20 Not connected

21 Not connected

Input 4 10 Not connected

11 Fill level (+24V) X

12 Not connected

22 Fill level (signal) X

23 Fill level (0V) X

24 Not connected

2-wire switch • Switches, buttons, etc. (machine contact) • Cycle switch (2-wire cycle switch only) 177-300-091, -092, -096 • Pressure switch • Differential-pressure switch (requires 2 inputs) • Mech. ill level switch (FF and FB pumps) 3-wire switch • Ultrasonic ill level switch • W2 ill level control (capacitive proximity switch)

Page 20 EN Assembly instructions

4.4.2 DuoFlex centralized lubrication system, terminal block X2, assignment of inputs with DDS50/1

Page 21: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

DuoFlex centralized lubrication system, terminal block X2, inputs and outputs with differential-pressure switch DDS50/1

Cabletype Cabletype

Term

inal

blo

ck: X

2

Aim

1

Terminal-No.

Bridge

BMK

Connector

Position

Differential-pressure switch 5G0,75

1 2 3 4 5 6 7 8 9 10 11 12 PE PE 13 14 15 16 17 18 19 20 21 22 23 24 PE PE

Delay extension Fill level

1 2

2X0,75 3X0,75

grge3 4

1 2

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 1

+ D

elay

ext

ensi

on

- D

elay

ext

ensi

on

+24

V Fi

ll le

vel

Sig

nal F

ill le

vel

OV F

ill le

vel

Diff

eren

tial-

pre.

sw

.

1 2 3 4

Pre

ssur

e, li

ne 2

Pre

ssur

e, li

ne 2

Cus

tom

er

Cus

tom

er

1 2 3

F F

ill le

vel

1 2 3PE+ -

Fill

leve

l F

ill le

vel

Diff

eren

tial-

pre.

sw

itch

Diff

eren

tial-

pre.

sw

itch

Diff

eren

tial-

pre.

sw

itch

Diff

eren

tial-

pre.

sw

itch

Diff

eren

tial-

pre.

sw

itch

Page 21 ENAssembly instructions

DuoFlex centralized lubrication system, terminal diagram X2, assignment of inputs with DDS50/1

Page 22: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Terminal diagram X2, 24 VDC/230 VAC/400 VAC

Terminal block X2 (400V, 230V, 24V)

Input No. Function 2-wire switch

3-wire switch

Analog sensor

Input 1 1 Cycle switch (+) X

2 Not connected

3 Cycle switch (-) X

13 Not connected

14 Not connected

15 Not connected

Input 2 4 Cycle switch (+) X

5 Not connected

6 Cycle switch (-) X

16 Not connected

17 Not connected

18 Not connected

Input 3 7 Delay extension (+) X

8 Not connected

9 Delay extension (-) X

19 Not connected

20 Not connected

21 Not connected

Input 4 10 Not connected

11 Fill level (+24V) X

12 Not connected

22 Fill level (signal) X

23 Fill level (0V) X

24 Not connected

Page 22 EN Assembly instructions

4.4.3 ProFlex centralized lubrication system, terminal block X2, assignment of the inputs

Page 23: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

ProFlex centralized lubrication system, terminal block X2, inputs and outputs

Cabletype Cabletype

Term

inal

blo

ck: X

2

Aim

1

Terminal-No.

Bridge

BMK

Connector

Position

Cycle switch 1 2X0,75

1 2 3 4 5 6 7 8 9 10 11 12 PE PE 13 14 15 16 17 18 19 20 21 22 23 24 PE PE

Delay extension Fill level

1 2

2X0,75 3X0,75

1 2

1 2

Cyc

le s

w. L

ine

1

Cycl

e sw

. Lin

e 1

+ D

elay

ext

ensi

on

- D

elay

ext

ensi

on

+24

V Fi

ll le

vel

Sig

nal F

ill le

vel

OV F

ill le

vel

1 2 3 4

Cyc

le s

w. L

ine

2

Cyc

le s

w. L

ine

2 C

usto

mer

Cus

tom

er

1 2 3

Fill

leve

l1 2 3+ -

Fill

leve

l F

ill le

vel

Cy

cle

switc

h 1

Cycle switch 2 2X0,75

Cycl

e sw

itch

1

Cycl

e sw

itch

2

Cycl

e sw

itch

2

Page 23 ENAssembly instructions

ProFlex centralized lubrication system, terminal diagram X2, assignment of inputs

Page 24: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Terminal diagram X2, 24 VDC/230 VAC/400 VAC

Terminal block X2 (400V, 230V, 24V)

Input No. Function 2-wire switch

3-wire switch

Analog sensor

Input 1 1 Pressure switch (+) X

2 Not connected

3 Pressure switch (-) X

13 Not connected

14 Not connected

15 Not connected

Input 2 4 Pressure switch (+) X

5 Not connected

6 Pressure switch (-) X

16 Not connected

17 Not connected

18 Not connected

Input 3 7 Delay extension (+) X

8 Not connected

9 Delay extension (-) X

19 Not connected

20 Not connected

21 Not connected

Input 4 10 Not connected

11 Fill level (+24V) X

12 Not connected

22 Fill level (signal) X

23 Fill level (0V) X

24 Not connected

Page 24 EN Assembly instructions

4.4.4 MonoFlex centralized lubrication system, terminal block X2, assignment of the inputs with pressure switches

Page 25: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

MonoFlex centralized lubrication system, terminal block X2, inputs

Cabletype Cabletype

Term

inal

blo

ck: X

2

Aim

1

Terminal-No.

Bridge

BMK

Connector

Position

Pressure switch, line 1 2X0,75

1 2 3 4 5 6 7 8 9 10 11

12

PE

PE

13

14

15

16

17

18

19

20 21

22

23

24

PE

PE

Delay extension Fill level

1 2

2X0,75

3X0,75

1 2

1 2

Pre

ssu

re, l

ine

1

Pre

ssu

re, l

ine

1

+ D

elay

ext

ensi

on

- D

elay

ext

ensi

on

+2

4V

Fill

leve

l

Sig

na

l Fill

leve

lO

V F

ill le

vel

1 2 3 4

Cus

tom

er

Cus

tom

er

1 2 3

Fill

leve

l1 2 3+ -

Fill

leve

l F

ill le

vel

Pre

ssu

re s

wit

ch 1

Pressure switch, line 2 2X0,75

Pre

ssu

re s

wit

ch 1

Pre

ssu

re s

wit

ch2

Pre

ssu

re, l

ine

2

Pre

ssu

re, l

ine

2 P

ress

ure

sw

itch

2

Page 25 ENAssembly instructions

MonoFlex centralized lubrication system, terminal diagram X2, assignment of inputs with pressure switches

Page 26: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Terminal diagram X2, 24 VDC/230 VAC/400 VAC

Terminal block X2 (400V, 230V, 24V)

Input No. Function 2-wire switch

3-wire switch

Analog sensor

Input 1 1 Not connected

2 Pressure sensor 1 (+24V) X

3 Not connected

13 Pressure sensor 1 (signal) X 1)

14 Pressure sensor 1 (0V) X 1)

15 Not connected

Input 2 4 Not connected

5 Pressure sensor 2 (+24V) X

6 Not connected

16 Pressure sensor 2 (signal) X 1)

17 Pressure sensor 1 (0V) X 1)

18 Not connected

Input 3 7 Delay extension (+) X

8 Not connected

9 Delay extension (-) X

19 Not connected

20 Not connected

21 Not connected

Input 4 10 Not connected

11 Fill level (+24V) X

12 Not connected

22 Fill level (signal) X

23 Fill level (0V) X

24 Not connected

1) When analog sensors are used, a BES6 plug-in jumper (fitted with a x.x kΩ, 0.5W resistor) must be inserted between “Signal (-)” and “Power supply (-)” in order to adapt the mea-surement range.

Page 26 EN Assembly instructions

4.4.5 MonoFlex centralized lubrication system, terminal block X2, assignment of the inputs with analog pressure sensors

Page 27: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

MonoFlex centralized lubrication system, terminal block X2, inputs with pressure sensors

Cabletype Cabletype

Term

inal

blo

ck: X

2

Aim

1

Terminal-No.

Bridge

BMK

Connector

Position

1 2 3 4 5 6 7 8 9 10 11 12 PE PE 13 14 15 16 17 18 19 20 21 22 23 24 PE PE

Pressure sensor, line 1

Pressure sensor, line 2 Delay extension Fill level

3X0,75 3X0,75 2X0,75 3X0,75

1 2 3

1 2 3

1kΩ 1kΩ

1 2

+ D

elay

ext

ensi

on

- PD

elay

ext

ensi

on

Cus

tom

er

Cus

tom

er

+ -

+24

VF il

l lev

el

Sig

nal F

ill le

vel

OV F

ill le

vel

1 2 3

Fill

leve

l1 2 3

Fill

leve

l F

ill le

vel

1 341 34

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 2

Pre

ssu

re s

en

sor

1

Pre

ssu

re s

en

sor 2

Pre

ssur

e, li

ne 1

Pre

ssur

e, li

ne 1

Pre

ssu

re s

en

sor

1 P

ress

ure

se

nso

r 1

Pre

ssu

re s

en

sor 2

P

ress

ure

se

nso

r 2

Pre

ssur

e, li

ne 2

Pre

ssur

e, li

ne 2

Page 27 ENAssembly instructions

MonoFlex centralized lubrication system, terminal diagram X2, assignment of inputs with analog pressure sensors

Page 28: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

X3, 24 VDC

Assignment of terminal block X3 with 24 VDC

1 Output 1 (+)2 Output 2 (+)3 Fault signal (+)4 Output 1 (-)5 Output 2 (-)6 Fault signal (-)PE Protective (earth) conductorPE Protective (earth) conductor

X3, 230 VAC/400 VAC 3-phase

Assignment terminal block X3, 230/400 VAC

1 Output 1 (+)2 Output 2 (+)3 Fault signal (Com)4 Not connected5 Output 1 (-)6 Output 2 (-)7 Fault signal (NC) 8 Fault signal (NO) PE Protective (earth) conductor

Cabletype Cabletype

Term

inal

blo

ck: X

3

Aim

1

Terminal-No. Bridge

BMK

Connector

Position

Valve 1 Valve 2

3G1 3G1

1 2 3 PE PE 4 5 6 PE PE

Fault signal 2X0,75

1 1 PE PE 2 2

1 2

1 2

grge

grge

1 2

Cus

tom

er

Cus

tom

er

Fau

lt si

gnal

Fau

lt si

gnal

+ -

Val

ve, l

ine

1 V

alve

, lin

e 2

Val

ve, l

ine

1 V

alve

, lin

e 2

VVa

lve,

line

1 V

alve

, lin

e 2

Cabletype Cabletype

Term

inal

blo

ck: X

3

Aim

1

Terminal-No. Bridge

BMK

Anschluss

Ort

Valve 1 Valve 2

3G1 3G1

1 2 3 4 PE PE 5 6 7 8 PE PE

Fault signal NC Fault signal NO

2X0,75 2X0,75

1 1 PE PE 2 2

1 2

1 2

grge

grge

1

1

2

2

Cus

tom

er

Cus

tom

er C

usto

mer

Fau

lt si

gnal

Fau

lt si

gnal

Fau

lt si

gnal

Val

ve, l

ine

1 V

alve

, lin

e 2

Val

ve, l

ine

1 V

alve

, lin

e 2

Val

ve, l

ine

1 V

alve

, lin

e 2

Page 28 EN Assembly instructions

4.5.1 Terminal block X3, outputs, 24 VDC

24 VDC type

The fault signal can be programmed

as either an NC contact or an NO contact.

NC = signal is interrupted in case of fault

NO = signal is sent in case of fault

4.5.2 DuoFlex centralized lubrication sys-

tem, terminal block X3, outputs,

230/400 VAC 3-phase

4.5 Assignment of terminal block X3,

outputs

Page 29: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Control cubicle, Fig. 6

Page 29 ENAssembly instructions

4.6 Finishing assembly work

Tighten the cable glands (conduit thread screw

unions) (1) and check for leaks and correct

positioning

Remove any foreign objects such as tools,

parts of cables etc. from the control

cubicle; clean any dirt from the control

cubicle without using cleaning agents

Visually inspect the assembly work that

was carried out

Lock the control cubicle door (2) and hand

the key to the person responsible for it

Switch on the basic switch (3)

Set the LC502 control unit in accordance

with the operating instructions for the

LC502 control cubicle and for the LC502

control unit

Check that the direction of rotation of the

pump motor is correct

Schmierung starten

Start lubrication

FehlerFault

1

2

3

ON

2

3

1

Made in Germany

SKF Lubrication Systems Germany GmbH

4.7 Note on the rating plate

The rating plate on the LC502 control cubicle

provides important data such as the type

designation, order number, barcode, and serial

number.

To avoid loss of this data in case the rating

plate becomes illegible, these characteristics

should be entered in the following table.

Enter key data from rating plate in the fol-

lowing table.

Fig. 9 Key data from rating plate

Serial number

Page 30: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions
Page 31: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Operating instructions associated with assembly instructions according to EC Dir. 2006/42/EC for partly completed machinery

LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex

centralized lubrication systems

Page 32: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 32 EN 1. Safety instructions / 2. Lubricants

1. Safety instructions

Warning!

These operating instructions must be

read and properly understood by the

assembler and the responsible techni-

cal personnel/operator before assembly

and commissioning.

The safety instructions listed in Chapter 1,

"Safety instructions," of the assembly instruc-

tions also apply without restrictions to these

operating instructions.

General information

In addition to the operating instruc-

tions, general statutory regulations and

other binding regulations for accident

prevention and for environmental

protection (recycling/disposal) must be

observed and applied.

2. Lubricants

Warning!

The information on lubricants listed in

Chapter 2, "Lubricants," of the assem-

bly instructions also applies without

restrictions to these operating instruc-

tions.

Disclaimer of liability

SKF Lubrication Systems Germany GmbH

shall not be held liable for damages:

Caused by contaminated or unsuitable

lubricants

Caused by the installation of non-original

SKF components or SKF spare parts

Caused by inappropriate usage

Resulting from improper assembly, con-

iguration, or illing

Resulting from improper response to mal-

functions

Caused by independent modiication of sys-

tem components

Only media approved for these types of

pump units may be used. Unsuitable media

may result in pump unit failure and po-

tentially severe bodily injury and property

damage.

Page 33: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 33 EN

3. Transport, delivery, and storage

Warning!

The product must not be tilted or

dropped.

3. Transport, delivery, and storage

SKF Lubrication Systems Germany GmbH

products are packaged in accordance with

standard commercial practice according to the

regulations of the recipient's country and

DIN ISO 9001. During transport, safe handling

must be ensured and the product must be

protected from mechanical effects such as im-

pacts. The transport packaging must be

marked "Do not drop!".

There are no restrictions for land, air, or sea

transport.

After receipt of the shipment, the product(s)

must be inspected for damage and for com-

pleteness according to the shipping docu-

ments. The packaging material must be pre-

served until any discrepancies are resolved.

SKF Lubrication Systems Germany GmbH

products are subject to the following storage

conditions:

3.1 Lubrication units

Ambient conditions: dry and dust-free

surroundings, storage in well ventilated

dry area

Storage time: max. 24 months

Permissible humidity: < 65%

Storage temperature: 10 - 40°C

Light: avoid direct sun or UVexposure and

shield nearby sources of heat

3.2 Electronic and electrical devices

Ambient conditions: dry and dust-free

surroundings, storage in well ventilated

dry area

Storage time: max. 24 months

Permissible humidity: < 65%

Storage temperature: 10 - 40°C

Light: avoid direct sun or UV exposure

and shield nearby sources of heat

3.3 General notes

The component(s) can be enveloped

in plastic film to provide low-dust storage.

Protect against ground moisture by

storing on a shelf or wooden pallet.

Bright-finished metallic surfaces,

especially wearing parts and assembly

surfaces, must be protected using

long-term anti-corrosive agents before

storage

At approx. 6-month intervals: Check

for corrosion. If there are signs of corrosion,

reapply anti-corrosive agents.

Drives must be protected from

mechanical damage.

Page 34: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Control cubicle, Fig. 1

Key to control and display elements

1 Basic switch To supply or disconnect power between customer's power supply and the LC502 control cubicle

2 LC502 display For programming, monitoring, and fault readout for the LC502 control unit

3 Start button (230/400 VAC type only) To start the programmed centralized lubrication system

4 Fault indicator light (230/400 VAC types only) Lights up when there is an active fault signal

Page 34 EN 4. Assembly/5. Design and function/6. Control and display elements

4.1 Information on assembly

The assembly procedure for the LC502 control

cubicle is described in detail in the assembly

instructions associated with these operating

instructions.

4. Assembly 5. Design and function

5.1 General information

The LC502 control cubicle is designed as a

compact module for simple assembly and con-

tains the LC502 control unit as well as all

components essential for a control cubicle, such

as the basic power switch, motor circuit break-

er (230/400 VAC types), start button, and fault

indicator light.

The display itted to the front can be used to

enter customer-speciic system settings in a

simple and easy-to-follow way. The control

cabinet meets the requirements of the IP54

safety class if the cable glands are assembled/

closed as described in the assembly

instructions.

The LC502 control cubicle and its components

is designed for the control of either dual-line,

progressive, or single-line centralized lubrica-

tion systems, depending on the coniguration.

6. Control and display elements

Schmierung starten

Start lubrication

FehlerFault

1

2

3

2 3

1

4

Page 35: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 35 EN6. Control and display elements

6.1. Display and control elements of

the control screen

The display and control unit is protected from

water splashes and mechanical damage by

a transparent plastic cover. The cover must

be removed to program the unit and then

remounted afterwards.

LC502 control screen

1

2

3

Display and control elements of the control screen

Symbol Description Function

Display Menu display Displays values and parameters Fault notification

FAULT LED Indicates a fault Red LED flashes = fault detected Red LED lights up = fault on a signal input, no fault detected on pump control unit (fault is outside the pump)

PAUSE LED Indicates pause time Yellow LED lights up = active pump pause time on at least one main line

CONTACT LED Indicates contact time (pump operation) Green LED lights up = active pump run time

1 = Output 1 2 = Output 2

Indicator for pump outlet 1 and 2 LED for outlet 1 or 2 lights up = pump outlet 1 or 2 is switched on. Lubricant is delivered via the indi-cated line (1 or 2)

3 = Inputs Indicator for all signal inputs LED lights up = signal change on input port The LED lights up for approx. 1 second each time the signal on the input port changes.

ENTER key To confirm selection To confirm entry and values

2

1

3

Page 36: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 36 EN 6. Control and display elements

Display and control elements of the control screen

Symbol Description Function

Operator keys Operator keys For menu selection (navigation) For editing numerical values

Operator keys Operator keys for menu selection (navigation)(arrow key up/down/left)Go to the selected menu based on direction of arrow

Operator keys for editing numerical values(arrow key up/down) The numerical value is incremented/decremented based on direction of arrow.Press <arrow key right> or <arrow key left> to move the cursor position to the adjacent digit. To exit the editor window without saving the current change, press the key again after reaching the last digit.

Pressing <arrow key up> increments the selected digit by one.Pressing <arrow key down> decrements the selected digit by one.The input value for seconds and minutes can be between 0 and 59; for hours, a value between 0 and 65535 can be programmed.

Operator key for editing numerical values(arrow key right) Pressing the key moves the cursor one position to the right. If the cursor is on the right edge, the edit window closes and the changes are discarded.

DK key Pressing triggers an interim lubrication. Fault notifications are acknowledged and deleted Is ignored if pressed while in configuration mode.

Page 37: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Control cubicle, Fig. 2

Page 37 EN7. Commissioning

7.1 Setting parameters of the LC502

control unit

The LC502 control unit comes in different

types, for dual-line, single-line, and progres-

sive centralized lubrication systems.

The control unit is tailored to the specific lu-

brication system; it is not possible to change

the lubrication system (DuoFlex, ProFlex,

MonoFlex) within the control.

There is a separate LC502 control unit manual

for each of the three lubrication systems; this

manual accompanies the LC502 control cu-

bicle and must be used when programming

the control unit.

Schmierung starten

Start lubrication

FehlerFault

1

2

3

3/4 2

1

7. Commissioning

Warning!

Refer to the operating instructions

provided by the manufacturer of the

lubrication system and follow the pro-

cedures speciied for initial start-up and

commissioning.

These three manuals are as follows:

LC502DuoFlex for dual-line centralized

lubrication systems,

document No. 951-180-007-EN

LC502ProFlex for progressive centralized

lubrication systems,

document No. 951-180-005-EN

LC502MonoFlex for single-line centralized

lubrication systems,

document No. 951-180-004-EN

Switch on the basic switch (1)

Note! The starter button is fitted on the

230/400 VAC types only.

With a 230 VAC/400 VAC type:

Press the starter button (2)

Remove the Plexiglas cover (3) from the

LC502 display screen

Using the LC502 display screen (4), set the

control unit as instructed in the operating

instructions LC502DuoFlex or

LC502ProFlex or LC502MonoFlex

Mount the Plexiglas cover (3)

Page 38: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 38 EN 8. Shutdown and disposal

8. Shutdown and disposal

8.1 Temporary shutdown

The described product can be shut down tem-

porarily by turning the basic switch to the

"OFF" position.

If the product is to be shut down for an ex-

tended period of time, follow the instructions

in Chapter 3, Transport, delivery, and storage.

When recommissioning the product, follow the

safety instructions in Chapter 1 of the assembly

instructions.

It may be necessary to set the parameters of

the control unit as instructed in 7.1, "Setting

parameters of the LC502 control unit."

8.2 Permanent shutdown

If the product will be permanently shut down,

the local regulations and laws regarding dis-

posal must be observed.

The product can also be returned to

SKF Lubrication Systems Germany

GmbH for disposal, in which case the

customer is responsible for reimbursing

the costs incurred.

Page 39: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 39 EN9. Maintenance

9. Maintenance

Warning!

Work on products that have not been

de-energized may result in bodily

injury. Assembly, maintenance and

repair work may only be performed on

products that have been de-energized

by qualiied technical personnel. Supply

voltage must be switched off before

opening any of the product's compo-

nents.

The LC502 control cubicle from SKF

Lubrication Systems Germany GmbH is low-

maintenance. However, all connections and

fittings must be inspected for proper seating

to ensure proper function and to prevent

hazards from arising.

Dismantling of the product or individual

parts thereof is not permitted and voids

any claims.

Arbitrary alterations and manufac-

ture of spare parts

Alterations or modiications to the control

cubicle are not permissible.

Original spare parts and accessories

authorized by the manufacturer serve

to ensure safety. The use of other parts

shall eliminate any liability for conse-

quences thereof.

SKF Lubrication Systems Germany GmbH

shall not be held liable for damages resulting

from improperly performed assembly, mainte-

nance or repair work on the product.

9.1 General information

The LC502 control cubicle is maintenance-

free in principle. However, do not allow any

dirt to enter the interior of the control cubicle.

Depending on the location where the LC502

control cubicle is installed, extreme weather

conditions may cause water condensate to

form inside the control cubicle. In such cases,

the system owner/operator must provide a

remedy (e.g. protection from the effects of

weather).

Page 40: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

X 2

X 1

X 3

24

9 10 1112

2322212019181716151413

1 2 3 4

5 6 7 8

PE PE

5 6 7 8

1 2 3 4

1 2 3 4 5 6 7 8

242322212019181716151413

9 10 11121 2 3 4 5 6 7 8

L1 N PE 1 2 PE PE

PE PE

6-K

2

8-K

4

8-K1M

6-Q2

6-T1 6-F

16

-F2

6-Q1

Control cubicle, Fig. 2

Glass fuse

Description (2) Fuse F1 400V and 230V: miniature slow-blow fuse, 5x20mm, 2A(3) Fuse F2 400V, 230V, and 24V: miniature slow-blow fuse, 5x20mm, 4A

F1 F2

Page 40 EN 9. Maintenance

Change the fuses as follows:

Switch the basic switch (1) to the "OFF"

position

Open the door of the LC502 control cubicle

The fuse holders are opened by pulling out

the upper retainer section of fuse holder 1

and/ or fuse holder 2.

Pull out the upper section of the fuse re-

tainer (2) (3); turn the retainer down

Take the glass fuse out of retainer 2 or 3

and insert a new glass fuse

Turn retainer 2 or 3 back into place and

press the retainer into the fuse holder

9.2 Changing defective fuses

(230/400 VAC 3-phase type only)

1

2 3

"OFF"

Page 41: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Control cubicle, Fig. 3

Page 41 EN

Warning!

Be sure to follow the safety instructions

in Chapter 1 of these operating instruc-

tions and the safety instructions in the

accompanying assembly instructions

(Chapter 1).

Warning!

In cases of functional failure, always

check whether all technical speciica-

tions have been adhered in the existing

operating conditions.

10. Malfunctions

10. Malfunctions

10.1 Program malfunctions, LC502

The fault signals displayed on the LC502

screen vary depending on the lubrication sys-

tem, so refer to the relevant LC502 assembly

instructions in order to remedy the faults.

LC502DuoFlex

for dual-line centralized lubrication systems,

document No. 951-180-007-EN

Chapter 10, Operational and pump faults

LC502ProFlex

for progressive centralized lubrication sys-

tems, document No. 951-180-005-EN

Chapter 10, Operational and pump faults

LC502MonoFlex

for single-line centralized lubrication sys-

tems, document No. 951-180-004-EN

Chapter 10, Operational and pump faults

1

2

3

Program malfunctions-See LC502 assembly instructions, Chapter 10

Page 42: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 42 EN

Malfunctions

Malfunctions Cause Remedy

Short circuits Remedy the cause; check fuses F1 and F2, change if necessary

Display screen is

blank

Power supply is interrupted Check electrical connection provided by the customer

Check that the basic switch is set to the "ON" position

In the case of the 230/400 VAC type: start the program with the

"Control On" button

Check fuses F1 and F2, change if necessary

Fuses F1 and F2: see Chapter 12, Spare parts

Red fault indicator

light is lit

Motor circuit breaker is not set Set the motor circuit breaker as instructed in Chapter 4.3.5

10.2 Commissioning malfunctions

10. Malfunctions

Page 43: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 43 EN10. Malfunctions

Malfunctions

Malfunctions Cause Remedy

Fault signal for

pressure build-up/

cycle switch

(red LED is lit)

Pressure/cycles not reached within

the predefined monitoring time

Differential-pressure switch is defective

Run time is too short

Incorrect run times and pause times

Pressure switch defective

Pressure build-up time is set too short

Progressive feeder is not supplying

lubricant

Faulty cable from the piston detector

Monitoring time was

entered incorrectly

Motor circuit breaker tripped

Fill level is below minimum

Check the lines for leaks, remedy any leaks

DuoFlex

Check the differential-pressure switch, adjust or replace it if nec-

essary

Extend the run time for pressure build-up

Check the parameters for run time and pause time, extend times

if necessary

MonoFlex

Check the pressure switch, adjust or replace it if necessary

Extend the pressure build-up time if necessary

ProFlex

Check the progressive feeder for blockage, replace if necessary

Check the connection of the piston detector, replace the connecting

cable if necessary

Check the piston detector, replace if necessary

Extend the monitoring time

Check the motor voltage, change pump motor if necessary

Fill the lubricant reservoir

Reset the red fault indicator by pressing the display's DK key

10.3 Operational malfunctions

Page 44: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

Page 44 EN

11. Technical data

Characteristics

Installation

Mounting position Vertical, cable terminals pointing downwards Total weight 8.2 kg

Electrical data

Temperature range 0 °C to 60 °C

Control unit LC502DuoFlex or LC502MonoFlex or LC502ProFlex

Rated voltage 24 VDC 230 VAC 400 VAC 3-phase

Rated output 0,16 ... 0,25 kW 0,15 ... 0.85 kW 0.15 kW ... 0.85 kW

Frequency 50 to 60 Hz 50 to 60 Hz

Protection class IP 54

Connection type Terminals

12. Spare parts

Spare parts

Description Order No.

Miniature fuse

slow-blow, 2 A (F1) SM-K26030203

Miniature fuse

slow-blow, 4 A (F2) SM-K26030403

LED element, green "Start control" 44-2392-3600

LED element, red

"Fault indicator light" 44-2392-3601

Other spare parts are listed in the

separate bill of materials accompany-

ing the control cabinet.

11. Technical data / 12. Spare parts

Page 45: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions
Page 46: LC502 control cubicle riinal assembly instructions EN … · EN LC502 control cubicle for use in ProFlex/MonoFlex/DuoFlex centralized lubrication systems riinal assembly instructions

951-170-215-EN

Version 03

The contents of this publication are the copyright of the publisher and may not be reproduced

in whole or in part without permission of SKF Lubrication Systems Germany GmbH . Every

care has been taken to ensure the accuracy of the information contained in this

publication. However, no liability can be accepted for any loss or damage, whether direct,

indirect or consequential, arising out of use of the information contained herein.

All SKF products may be used only for their intended purpose as described in these assembly in-

structions with associated operating instructions. If assembly/operating instructions are sup-

plied together with the products, they must be read and followed. Not all lubricants can be fed

using centralized lubrication systems. SKF can, on request, inspect the feedability of the lubri-

cant selected by the user in centralized lubrication systems. Lubrication systems and their

components manufactured by SKF are not approved for use in conjunction with gases, lique-

fied gases, pressurized gases in solution, vapors or such fluids whose vapor pressure exceeds

normal atmospheric pressure (1013 mbar) by more than 0.5 bar at their maximum permis-

sible temperature.

Particular attention is called to the fact that hazardous substances and mixtures as defined in

Annex I Part 2-5 of the CLP Regulation (EC 1272/2008) may only be filled into SKF central-

ized lubrication systems and components and delivered and/or distributed with such systems

and components after consulting with and obtaining written approval from SKF.

SKF Lubrication Systems Germany GmbH

2. Industriestrasse 4 ·68766 Hockenheim · Germany

Tel. +49 (0)62 05 27-0 · Fax +49 (0)62 05 27-101

www.skf.com/lubrication

SKF Lubrication Systems Germany GmbH

Motzener Strasse 35/37 ·12277 Berlin · Germany

PO Box 970444 · 12704 Berlin · Germany

Tel. +49 (0)30 72002-0 · Fax +49 (0)30 72002-111

www.skf.com/lubrication