lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For...
Transcript of lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For...
ContentsC
omm
erci
al
Dom
estic
01
Regulations
Bathroom/ WCKitchen/ Utility Rooms Cooker HoodsWhole house SystemsDomestic/Commercial Inline FansWall and Window fansHeat Recovery Ventilation UnitsCooker HoodsCeiling Sweep FansHand and Hair DryersAir Curtains
AccessoriesWiring diagrams
02
0416263038 404854565860
6470
Ventilation requirements Building RegulationsApproved Document F (2006)
02
The Building Regulations for England and Wales require that all building plans must now provide extract ventilation in every wet room (kitchens, bathrooms, WCs and utility rooms). In Commercial or office buildings alongside the extract ventilation rates for specific rooms there is a minimum air supply rate of 10l/s per person.The required ventilation performance will be achieved by providing the airflow rates set out in Tables 1 & 2. The airflow rates specified are for the performance of the complete installation. Extract ventilation to outside is required in each kitchen, utility room and bathroom and for sanitary accommodation (WCs). The extract can can be either intermittent or continuously operating. The intermittent rate, and for continuous systems the minimum extract airflow rates at the highest and lowest settings, should be no less than specified in Table 1.
The whole dwelling ventilation rate for the supply of air to the habitable rooms in a dwelling should be no less than specified in Table 2.
For current Building Regulations in Scotland check online at www.sbsa.gov.ukFor current Building Regulations in Northern Ireland check online at www.dfpni.gov.uk
Table 1. Extract ventilation rates
Room type Intermittent extract Continuous extract
Minimum rate Minimum Minimum high rate low rate Kitchen 30 l/s (108m3/hr) at hob; or 13 l/s (47m3/hr) Total extract rate should be at least the whole 60 l/s (216m3/hr) elsewhere house or dwelling ventilation rate given in table below Utility room 30 l/s (108m3/hr) 8 l/s (29m3/hr)
Bathroom 15 l/s (54m3/hr) 8 l/s (29m3/hr)
WC or Sanitary 6 l/s (22m3/hr) 6 l/s (22m3/hr) accommodation
Table 2. Whole house or dwelling ventilation rates
Number of bedrooms in dwelling
1 2 3 4 5
Whole house or dwelling 13 17 21 25 29 ventilation rate a,b (l/s) (47m3/hr) (61m3/hr) (76m3/hr) (90m3/hr) (104m3/hr)
Notes: a. In addition, the minimum ventilation rate should not be less than 0.3 l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas.)
b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4 l/s(14.4m3/hr) per occupant.
03
Ventilation systems
System 1 Background ventilators and intermittent extract (LEV) fans. Guidance on minimum provisions forextract andwhole dwelling ventilation is set out in Table 1. above. (See catalogue pages 4 to 25 for Soler & Palau fans and ventilation products to meet these performance requirements)
System 3 Continuous mechanical extract (MEV). Guidance on (MEV) minimum provisions for extract andwhole dwelling ventilationis set out in Table 2. above.(See catalogue pages 26 to 29 for Soler & Palau fans and ventilation products to meet these performance requirements)
Select one of the following four ventilation systems options:
System 2 Passive stack ventilation (PSV).(PSV) Not offered by Soler & Palau.
System 4 Continuous mechanical supply and extract with(MVHR) heat recovery (MVHR).Guidance on minimum provisions for extract and whole dwelling ventilation is set out in Table 2. above.(See catalogue pages 30 to 33 for Soler & Palau fans and ventilation products to meet these performance requirements)
Installation guidelines
• Site fan as far away as possible from air replacement points.• Site fan close to any source of moisture and high on walls or in ceiling.• Ensure there is adequate air replacement into the room to match the extract performance of the fan or ventilation system. This may require the provision of fresh air vents or an undercut to internal doors.• Avoid siting fans near sources of heat.• To prevent condensation forming in any ductwork, insulate ducting that runs through cold roof spaces.
Bathroom/ WC
04 SILENT Series Range of axial extractors with airflow rates of approx.100 m3/h, for connection to 100 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb noise and vibration and create a very low noise level. All the fans are manufac-tured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, energy-saving motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.Ballrace bearings ensure long life at any mounting angle.
IP45 Water protected
26.5 dB (A) Low noise
8Wconsumption
Energy efficient
Model provided with an elec-tronic humidi-stat which can be adjusted to 60, 70, 80 or
90% HR using a key located on the front grille.Four indicators show the desired level of humidity. The extractor operates automatically when the humidity level in theroom is higher than the set level. The extractor will stop automati-cally when the humidity dropsbelow the selected level and after the selected period set on the ad-justable timer (1 and 30 minutes).
Model provided with a PIR (pas-sive infra-red)detector. The unit starts auto-matically when
a movement is detected within a maximum distance of 4 meters from the fan. They are also fitted with an adjustable “run on” timer, from 1 to 30 minutes, to allow the fan contin-ues operating after the initiation of the movement detection.
SILENT-100 12V must be wired to a safety isolating transformer CT-12/14 which must be located out of the reach of the water spray or person using a bath or shower. The transformer is IP21, class II insulation and protected by fuse. Also available, Transformer CT12/14 R, supplied with adjust-able run-on-timer between 1 to 30 minutes.
Model SELV (Safety Extra Low Voltage). Specially designed to operate within the shower or bath volume with total safety. They are rated 12V, Class III and IP57.
SILENT 100 CZ 12V SILENT 100 CDZ SILENT 100 CHZ VISUAL
Ceiling or wall mounted with discharge directly to the outside or through duct system
Installation examples
05
Bathroom/ WC
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100WBack draft shutter
Fixed shutter and telescopic duct (200-400mm)
Window
Quiet operation
SILENT -100 Usual extractorIn most extract fans the vibration is transmitted to the surrounding areas while in SILENT extractor fans the vibrations are absorbed by acoustic mounting blocks.
Dimensions (mm)
PPa mmcda
40
35
30
25
20
15
10
5
0
4
3,5
3
2,5
2
1,5
1
0,5
0
PPa mmcda
m3/h
m3/sQ
0 20 40 60 80 100
0.00 0.01 0.02
90
80
70
60
50
40
30
20
10
0
9
8
7
6
5
4
3
2
1
0 m3/h
m3/sQ
0 50 100 150 200 250 300
0.00 0.02 0.04 0.05 0.08
Performance curves SILENT100
Models features CZ CRZ CRIZ CHZ CHZ CDZ CZ (12V) CZ CRZ
VISUAL SILVER SILVER
Neon light • • • • • • • Backdraft shutter • • • • • • • • • Timer (1-30min) • • • • * • Automatic timer • Adjustable humidistat • • • PIR • Ball bearings • • • • • • • • Silver colour • • •* Using CT-12/14R transformer • • • •
Technical characteristics Model Speed Abs power Voltage Sound Airflow Insulation Weight
at free (V) pressure at free IP
discharge 50Hz level discharge
(W) (dB(A)) (M3/h) (dB(A)) (kg)
SILENT-100 2400 8 230 26.5 95 II / IP45 0,57
SILENT-100 12V 2320 13 12 26.5 95 / IP57 0,57
Bathroom/ WC
06 SILENT-100DESIGN
Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb vibration and offer a very low noise level. All the fans are manufacturedfrom injection moulded plastic, fitted with automatic shutter and singlephase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.
• Elegant design• Very low noise: 26,5 dB(A)• Low power consumption : 8W• IP 45• Backdraftshutter• Versions with electronic run-o n time r (CRZ) and adjustable humidistat (CHZ)• LED Indicator
Back draft shutter
Motor mounted on “Silent-elastic-block” to prevent vibration and noise transmission
Silent-blocks
To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the prescence of the air
IP45 Water protected
26.5 dB (A) Low noise
8Wconsumption
Energy efficient
Quiet operation
SILENT -100 DESIGN Usual extractorIn most extract fans the vibration is are transmitted to the surrounding areas while in SILENT extractor fans the vibrations are absorbed by acoustic mounting blocks
Technical characteristics Model Max. power Supply Sound Airflow Weight Insulation
at free Voltage pressure at free class /
discharge (V-Hz) level* dB(A) discharge IP
(W) (m3/h) (kg)
SILENT-100 DESIGN 8 230V~50Hz 26,5 80 0,65 II / 45
* Sound presure level measured at 3m at free air conditions
SILENT-100DESIGN
07
Bathroom/ WCModels features
CZ CRZ CHZ CZ SILVER CRZ SILVER CHZ SILVER
LED indicator • • • • • • Backdraft shutter • • • • • • Adjustable Run-On-Timer 1-30mins • • • • Adjustable humidistat • • Ball bearings • • • • • • Silver finish • • •
Dimensions (mm) Performance curve SILENT-100 DESIGN
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100WBack draft shutter
Fixed shutter and telescopic duct (200-400mm)
Window
Bathroom/ WC
08 DECOR -100
Slim line axial flow fans for wall or ceiling installation, designed to remove odours and moisture in small rooms, toilets and bathrooms. The DECOR Series are easy to install, aesthetically pleasing, slim line and extremely quiet The DECOR-100 is available with many different integrated control options to accommodate all applications.
Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diam-eter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon light indicator and single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fans are class II insulation, IP44 rated and suitable to operate with air tempera-tures up to 40oC.
Ceiling or wall mounted with discharge directly to the outside or through duct system
Installation examples
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100WBack draft shutter
Wall kit with fixed or auto-matic shutter
Window Kit
To prevent air entry and limitheat leakage when the extractoris not operating. It opens auto-matically when the fan is activated
Back draft shutter
Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight Insulation
absorbed (V) air flow pressure class / IP
power 50Hz level
(rpm) (W) (m3/h) (dB(A))* (kg)
DECOR-100 2500 13 230 95 40 0,44 / IP44
* Sound pressure level at 1.5m
DECOR -100 09
Bathroom/ WC
Models features C CZ CR CRZ CH CHZ CD CDZ 12V C VISUAL
Neon light indicator • • • • • • • • • Automatic back draft shutter • • • • • • • • • Adjustable Run-On-Timer • • • • • • * Adjustable humidistat • • PIR detector • • Ball bearings • • • •
Dimensions (mm) Performance curve
PPa mmcda
40
35
30
25
20
15
10
5
0
4
3,5
3
2,5
2
1,5
1
0,5
0
PPa mmcda
m3/h
m3/sQ
0 20 40 60 80 100
0.00 0.01 0.02
90
80
70
60
50
40
30
20
10
0
9
8
7
6
5
4
3
2
1
0 m3/h
m3/sQ
0 50 100 150 200 250 300
0.00 0.02 0.04 0.05 0.08
To prevent air entry and limitheat leakage when the extractoris not operating. It opens due tothe pressure of the air
Back draft shutter Window kit
EDM-100 12V must be wired to a safety isolating transformer CT-12/14 which must be located out of the reach of the water spray or person using a bath or shower. The transformer is IP21, class II insulation and protected by fuse.Also available: Transformer CT12/14 R, supplied with adjustable run-on-timer between 1 to 30 minutes
CT-12/14 transformer
Model SELV (Safety Extra Low Voltage). Specially designed to operate within the shower or bath zone with total safety. They are rated 12V, Class IIIand IP57
EDM-100 12V SEDM-100 12V C
Bathroom/ WC
10 EDM -100
Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon light indicator (1) and single single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incor-porate long life motors fitted with ball bearings. All the fans are class II insulation (2), IP44 rated (3) and suitable to operate with air temperature up to 40oC.
(1) Except “S” Basic model(2) H versions: IP40(3) 12V Versions: IP57, class III insulation
EDM -100 12V EDM -100 C
Models features
S T R H C CT CR EC CH M VM VMH 12V S 12V C
Neon pilot light • • • • • • • • • • • • • Fixed period Run-On-Timer • • Adjustable period Run-On-Timer • • • • • * * Automatic shutter • • • • • • • • • • Photoelectric cell • Adjustable humidistat • • • On/off pull cord switch • • • • • Adaptation for glass • • External fixed shutter • • Safety Extra Low Voltage (SELV) • •
* Adjustable Run-On-Timer between 1 and 30 using CT-12/14 T transformer.
Bathroom/ WC
Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight IP
absorbed (V) air flow pressure
power 50Hz level
(rpm) (W) (M3/h) (dB(A))** (kg)
EDM-100 2450 13 230 95 40 0,48 IP44 *
EDM-100S 12V 2100 7 12 85 37 0,48 IP57
EDM-100C 12V 2100 11 12 85 37 0,48 IP57
* H versions: IP40 ** Sound pressure level at 1.5m
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100WBack draft shutter
Wall kit CAR-100Back draft shutter
30
25
20
15
10
5
0
PPa mmcda
3,5
3
2,5
2
1,5
1
0,5
0m3/h
m3/sQ
0 20 40 60 80
0,020,010,00
30
25
20
15
10
5
0
PPa mmcda
3,5
3
2,5
2
1,5
1
0,5
0m3/h
m3/sQ
0 20 40 60 80
0,020,010,00
Performance curve EDM-100
30
25
20
15
10
5
0
PPa mmcda
3,5
3
2,5
2
1,5
1
0,5
0m3/h
m3/sQ
0 20 40 60 80
0,020,010,00
30
25
20
15
10
5
0
PPa mmcda
3,5
3
2,5
2
1,5
1
0,5
0m3/h
m3/sQ
0 20 40 60 80
0,020,010,00
EDM-100 12V
Dimensions (mm)
11
12 EB -100
Bathroom/ WC
Centrifugal fans suitable for many domestic general ventilation applications where higher system resistance pressures are encountered.The EB models incorporate powerful forward curved centrifugal impeller with single phase 230V50Hz, 2-pole motor Class B insulation are available with a variety of fan function options.
EB-100 S Standard models.EB-100 T Models with adjustable run-on-timer.EB-100 HT Models with internal humidistat and adjustable run-on-timer.
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
MRT-100Circular duct joining piece
A C E
D
B
Dimensions (mm)
EB-100 are fitted with anautomatic back draft shutter toprevent air entry and limit heatleakage when the extractor isnot operating
Back draft shutter
To deliver high airflowperformance with a minimumof noise generation against highstatic pressure system resistance
Forward curvedcentrifugal impeller
140
120
100
80
60
40
20
0
PPa mmcda
14
12
10
8
6
4
2
0m3/h
m3/sQ
0 20 40 60 80
0,0050,000
100 120
0,0150,010 0,0250,020 0,030
PPa mmcda
m3/h
m3/sQ
0 50 100 150 200
0,010,00
250
0,030,02 0,050,04 0,06
280
240
200
160
120
80
40
0
28
24
20
16
12
8
4
0
Performance curveTechnical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP at free (V) at free pressure discharge 50 Hz discharge level (dB(A))
(r.p.m.) (W) (m3/hw) at 1,5 m (kg)
EB-100 2250 30 220-240 110 45,5 1,1 IPX4*
* H version: IPX2
Models features
S T HT
Neon light • • • Backdraft shutter • • • Adjustable Run-On-Timer • • Integral humidistat •
Extract ventila-tion throughthe wall or ceiling
Duct extract ventilation
Installation examples
13EBB -100 NEBB-100 N extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The range comprises three models, S, T and HT. EBB-N models incorporate powerful forward curved centrifu-gal impeller with 2-speed single phase 230V~50Hz, 2-pole motor.
“S” version: Standard model.“T” version: Model with adjustable run-on-timer.“HT” version: Model with internal humidistat and adjustable run-on-timer.
Models features
S T HT
Backdraft shutter • • • Metal filters • • • Two speed • • • Adjustable Run-On-Timer • • Integral humidistat •
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
MRT-100Circular duct joining piece
REBSingle phase electronic speed controllers
Dimensions (mm)
Performance curveTechnical characteristics Model Speed Maximum Voltage Airflow Sound Weight Insulation
absorbed (V) at free pressure class / IP
power 50Hz discharge level
(rpm) (W) (m3/h) (dB(A))* (kg)
HS 1600 35 130 46 EBB-100 N
LS 1050 15 230
75 34 1.88
/ IP44
* Sound pressure level at 1.5 m
Bathroom/ WC
Duct
SILENTUB -100In-line axial fan offering a very low noise leveland specifically designed to work through aduct or to be flush mounted into the wall, idealfor ventilating small areas or to exchange heatbetween adjoining rooms. Fitted with singlephase motors 230V-50Hz, IP44, Class II, withball bearings for enhanced working life andassembled on silent-blocks.
Performance curve
SILENTUB -100 is fitted with an automatic back draft shutter to prevent air entry and limit heat leakage when the extractor is not operating
Back draft shutter
Motor mounted on silent-elastic mounting block to absorb vibrations and reduce noise transmissions
Silent mounting blocks
Dimensions (mm)
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100W Back draft shutter
Mounting Foot PIE-100/120Support for wall fixing (accessory)
Bathroom/ WC
14
Bathroom/ WCTechnical characteristics
Model Speed Maximum Voltage Maximum Sound Weight
absorbed (V) air flow pressure
power 50Hz level
(rpm) (W) (m3/h) (dB(A)) (kg)
SILENTUB-100 2450 12 230V 100 37.5 0,5
MIXVENT -100 KITS
15
Bathroom/ WC
The TD ventilation kits enable the simple andfast installation of a complete ventilationsystem. The kits provide efficient extraction forbathrooms, toilets, washrooms and any otherapplications that require the removal of badodours, stuffy and humid air.3 kits are available:
KIT TD-160/100 N SILENT includes:1 TD-160/100 N SILENT fan+ 4 m of flexible aluminium ducting GSA-100+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA
KIT TD-250/100 includes:1 TD-250/100 fan+ 4 m of flexible aluminium ducting GSA-100+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA
Included:
GSA-100Flexible aluminium ducting
GRA-100Exterior mount grille
BA-50Adhesive aluminium duct tape (10m)
BOR-100Interior circular air valve
Installation and mounting
GRA-100
BOR-100
TD-160/100 N SILENTTD-250/100TD-250/100 T
Bathroom/ WC
WC
Bathroom
Internal WC/Bathroom
KIT TD-250/100T includes:1 TD-250/100 T fan+ 4 m of flexible aluminium ducting GSA+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA
The TD-250 T extractor is fitted with anadjustable Run-On- Timer between 1 and30 minutes, keeping the fan in operation forthe selected period of time after beingswitched off.
Internal WC/Bathroom
IP45 Water protected
Kitchen/Utility Room
16 SILENT-200 Range of axial extractors with airflow rates of approx. 180 m3/h, for connection to 125 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb the vibrations and offer a very low noise level. All the fans are manufactured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperatures up to 40oC.The SILENT-200 CZ and CRZ can be supplied with an aesthetic silver front grille.
Technical characteristics Model Speed Abs power Voltage Sound Air flow Insulation Weight
at free (V) pressure at free IP
discharge level discharge
(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)
SILENT-200 2350 16 230 33 180 II / IP45 0,77
* At 3m
Models features CZ CRZ CHZ
Pilot light • • • Backdraft shutter • • • Adjustable Run-On-Timer • • (1-30min) Adjustable humidistat • Ball bearings • • • Silver front grille • •
17
Kitchen/Utility Room
Dimensions (mm)
0 40 80 120 160
1
2
3
4
5
6
7
8
9
0
10
20
30
40
50
60
70
80
90
0.00 0.01 0.02 0.03 0.04 0.05
0
PPa mmcda
m3/h
m3/sQ
Performance curves SILENT-200
SILENT -200 is fitted with an automatic back draft shutter to prevent air entry
and limit heat leakage when the extractor is not operating
Back draft shutterMotor mounted on acoustic block to absorb vibrations and reduce noise transmissions
Silent-blocks SILENT-200
Accessories
GSA-125Flexible aluminium ducting
GRA-150Exterior mount grille
CX-125Worm drive ducting clip
PER-125WBack draft shutter
Range of axial extractors with airflow rates of approx. 300 m3/h, for connection to 150-160 mm diameter circular ducting.Motor mounted on silent-elastic-blocks (SILENT-300) which absorb the vibrations and offer a very low noise level. All the fans are manufactured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.The SILENT-300 CZ and CRZ can be supplied with an aesthetic silver front grille.
Models features CZ CRZ CHZ CZ PLUS CRZ PLUS CHZ PLUS
Pilot light • • • • • •Backdraft shutter • • • • • •Adjustable Run-On- • • • • Timer (1-30min) Adjustable humidistat • •Ball bearings • • • • • •Silver front grille • •
Technical characteristics Model Speed Abs power Voltage Sound Air flow Insulation Weight
at free (V) pressure at free IP
discharge level discharge
(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)
SILENT-200 1700 29 230 32 280 II / IP45 1,25
SILENT-300 PLUS 2000 17 230 36 320 II / IP45 1,65
* At 3m
Kitchen/Utility Room
18 SILENT-300
REBSingle phase electronic speed controllers
Accessories
GSA-150Flexible aluminium ducting
GRA-150Exterior mount grille
CX-150Worm drive ducting clip
PER-150WBack draft shutter
IP45 Water protected
SILENT -300 is fitted with an automatic back draft shutter to prevent air entry
and limit heat leakage when the extractor is not operating
Back draft shutterMotor mounted on silent-elastic block to absorb vibrations and reduce noise transmissions
Silent-blocks
Dimensions (mm)Performance curves SILENT-300
19
Kitchen/Utility Room
SILENT-300
DECOR -200 Range of axial extractors suitable for utility rooms with airflow rates of approx. 180 m3/h, for connection to 120 mm diameter circular ducting.All the fans are manufactured from injection moulded plastic, fitted with neon light indicator and single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fans are class II insulation, IP44 rated and suitable to operate with air temperatures up to 40oC.
40
30
20
10
0
PPa mmcda
m3/h
m3/sQ
0 40 80 120 160 200
0.00 0.01 0.02 0,03 0,04 0,05
4
3
2
1
0
Performance curves DECOR-200
Accessories
GSA-125Flexible aluminium ducting
GRA-150Exterior mount grille
PER-125WBack draft shutter
Dimensions (mm)
Models features C CZ CR CRZ CH
Neon light indicator • • • • • Automatic back draft shutter • • • • • Adjustable Run-On-Timer • • • Adjustable humidistat • Ball bearings • •
Back draft shutter
To prevent air entry and limitheat leakage when the extractoris not operating. It opens due tothe pressure of the air
Technical characteristics Model Speed Maximum Voltage Sound Maximum Weight IP
absorbed (V) pressure air flow
power level
(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)
DECOR-200 2500 20 230 45.5 185 0,8 IP44
* At 1.5m
20
Kitchen/Utility Room
DECOR - 300 21
Kitchen/Utility Room
Range of axial extractors suitable for kitchens with airflow rates of approx. 280 m3/h, for connection to 150-160 mm diameter circular ducting.All the fans are manufactured from injection moulded plastic and fitted with neon light indicator and single phase 230V-50Hz, class Bmotor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fansare class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.
PPa mmcda
m3/h
m3/sQ
0 60 120 180 240 300
0,080,060,040,020,00
0
7
6
5
4
3
2
110
0
20
30
40
50
60
70
Performance curves DECOR-300Technical characteristics Model Speed Maximum Voltage Sound Maximum Weight IP
absorbed (V) pressure air flow
power level
(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)
DECOR-300 2200 35 230 47 280 1,44 IP44
* At 1.5m
Dimensions (mm)
Models features S C CZ R CR CRZ H CH
Neon light indicator • • • • • • • • Automatic back draft shutter • • • • • Adjustable Run-On-Timer • • • • • Adjustable humidistat • • Ball bearings • •
Back draft shutter
To prevent air entry and limitheat leakage when the extractoris not operating. It is opened bythe pressure of the air flow
Accessories
GSA-150Flexible aluminium ducting
GRA-150Exterior mount grille
PER-150WBack draft shutter
REBSingle phase electronic speed controllers
Ceiling or wall mounted with discharge directly to the outside or through duct system
Installation examples
Kitchen/Utility Room
22 EBB 175EBB 250
The EBB extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The EBB models incorporate powerful forward curved centrifugal impeller with single phase 230V-50Hz, 4-pole (EBB-175) or 2-pole motor (EBB-250).
EBB-175 S and EBB-250 S: Standard models.EBB-175 T and EBB-250 T: Models with adjustable run-on-timer.
Models features S T DV HM Neon light • • • • Back draft shutter • • • • Adjustable Run-On-Timer • 2 speed • Pullcord • Humidstat •
EBB 175 EBB 250
23
Kitchen/Utility Room
EBB fans are fitted with anautomatic back draft shutter toprevent air entry and limit heatleakage when the extractor isnot operating
Back draft shutter
To deliver high airflowperformances with a minimumof noise generation against highstatic pressure system resistance
Forward curved centrifugal impeller
Performance curves
Technical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP
at free (V) at free pressure
discharge discharge level
(rpm) (W) 50Hz (m3/h) (dB(A))* (kg)
EBB-175 1400 70 230 175 45 2,2 IPX4
EBB-250 1800 125 230 230 52 2,2 IPX4
* At 1.5m
Ceiling or wall mounted with discharge directly to the outside or through duct system
Dimensions (mm) EBB 175 / EBB 250
170
136
7
7
Accessories
GSA-100Flexible aluminium ducting
GRA-70Aluminium exterior grille
CX-80/125Worm drive ducting clip
PER-100WBack draft shutter
Fixed shutter and telescopic duct (200-400mm)
Window
Installation examples
Surface mounted Flush mounted
Kitchen/Utility Room
24 EBB 170NEBB 250N
The EBB-N extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The range is comprised of EBB-170N and EBB-250N, each available in different versions. The EBB-N models incorporate powerful forward curved centrifugal impeller with 2-speed single phase 230V50Hz, 4-pole motors.
“S” version Standard models.“T” version Models with adjustable run-on-timer.“HT” version Models with internal humidistat and adjustable run-on-timer
Technical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP
at free (V) at free pressure
discharge discharge level
(rpm) (W) 50Hz (m3/h) (dB(A))* (kg)
EBB-170 N 1010 48 230 220 42,5 3 IP44
EBB-250 N 1225 51 230 270 46 3 IP44
* At 1.5m
Models features S T HT
Back draft shutter • • • Metal filters • • • Two speed • • • Adjustable Run-On-Timer • • Integral humidstat •
EBB 170NEBB 250N
25
Kitchen/Utility Room
170150
Ø 9
8
284
337
Dimensions (mm) EBB 170 / EBB 250N
Accessories
GSA-100Flexible aluminium ducting
GRA-100Exterior mount grille
MRT-100Circular duct joining piece
REBSingle phase electronic speed controllers
CX-80/125Worm drive ducting clip
Pa mmcda
P
120
110
100
90
80
70
60
50
40
30
20
10
0
12
11
10
9
8
7
6
5
4
3
2
1
0m3/h
m3/sQ
0 40 80 120 160
0,010,00
200 280
0,030,02 0,050,04 0,06
240
0,07
170VL
250VL
170VR
250VR
Performance curves EBB-170 N EBB-250 N
High
High
Low
Low
Cooker Hoods
26 HA-600 SLIMHA-900 SLIM
• Tangential motor/capacitor motor• IIlumination: 2 lamps of 40 W• Professional type metal filters• Frontal, push button, speed selector• Telescopic chimney• Backdraft shutter• Reducer for discharge conduit to 120 mm• Air recirculation through carbon filters• Chrome tray (optional)
Technical characteristics Model Airflow Diameter Motors Speed Voltage Power Current Sound
at free discharge pressure
discharge tube level
(m3/h) (mm) (r.p.m.) (V) (W) (A) (dB(A))*
HA SLIM 700 150 1 3 230 210 0,9 58
* At 1.5m
VERSIONS Stainless / White / BlackHA-600 Slim: 60 cm wideHA-900 Slim: 90 cm wide
Dimensions (mm)
Upper or rear extractionUpper or rear extraction. Easing the outlet installation of smoke and grease
Air recirculation of airCarbon filters allow use of the kitchen hood when the extraction function cannot operate.
Technical characteristics Model Airflow Diameter Voltage Power Absorbed Sound at free discharge current pressure discharge tube level
(m3/h) (mm) (V) (W) (A) (dB (A))
HP-60 300 120 230 130 1,30 47
CEB-60 N 300 120 230 130 1,30 52
GE-350N 300 120 230 130 1,30 51
GET-60NC 230 120 230 180 1,30 45
GET-60NF Plus 525 120 230 205 0,75 65
27
Cooker Hoods
VERSION: WhiteGE-350N: 56,5 cm wide
Dimensions (mm)
256286565
494
16
149
GE-350 N• Flush fitting• 3 speed• 240 W lamps• Metal filter• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)
GET-60 NC• Hood with telescopic glass extension• 3 speed• Safety switch• Illumination: two 40 W lamps• Metal filter• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)VERSION: White
GET-60NC: 60 cm wide
Dimensions (mm)
20
510
Ø120=
=
280
462
600
280
186
40
30
HP-60600
47084
66
150
495
Dimensions (mm)
• 3 speed• Two 40 W lamps• Metal filter• Backdraft shutter• Upper or rear extraction• Air recirculation through carbon filters (optional/available on request)VERSION: White
HP-60: 60 cm wide
GET-60 NF• Hood with telescopic extension filter• Capacitor motor• 3 speed• Safety switch• Illumination: two 20 W halogen lamps• Metal filters• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)
VERSION: StainlessGET-60NF PLUS: 60 cm wide
Dimensions (mm)
28 Extractors Centrifugal extractors manufactured from flameretardant plastic (V0). All extractors are class IIinsulation fitted with centrifugal impeller andsingle phase 230V 50Hz speed controllablemotor. This range consists of three models withairflow ranging up to 625 m3/h.
Metallic Teflon-coated filter
Fitted to the inlet to preventthe build-up of grease withinthe fan and ducting enclosure (CK-40F and CK-60F)
Protection guard
To avoid any contact with theimpeller (CK-25N)
To avoid any contact with theimpeller (CK-25N)
Removeable grease collection tray
CK-60F: 2-speed motor
REGUL-2 speed selector I/II switch to adapt the extractair volume to the needs
All the CK Series extractor parts are easily removable and can be cleaned in the dishwasher.
Easy to dismantle
The efficiency of the kitchen extractors depends on themaintenance and cleaning of the centrifugal impeller.
Cooker Hoods
Dimensions (mm)ØA
E
D
C
G
F
B
Model ØA B C D E F G
CK-25 N 98 34 304 149 218 – 127
CK-40 F 98 42 370 179 266 140 162
CK-60 F 116,5 42 362 180 293,5 145 174
29
To obtain the maximum efficiency of the polluted air extraction, the CK series fans should be installed within a cooker canopy.The airflow required depends upon the canopy width and the distance between the canopy and the cooker. The CK series fans should be installed in vertical position with the grease collection tray at the bottom.
Installation
600
560
520
480
440
400
360
320
280
240
200
160
120
80
40
0
PPa mmcda
m3/h
m3/sQ
0 100 200 300 400 500 600
0 0,025 0,050 0,075 0,1 0,125 0,150 0,175
60
56
52
48
44
40
36
32
28
24
20
16
12
8
4
0
CK-40
CK-25N
CK-60 VR
CK-60 VL
Performance curves SILENT-200
Model features CK-25 N CK-40 F CK-60 F
Grease collection tray • • • Protection guard • Metallic Teflon coated filter • • Removable • • • Washable in a dishwasher • • • Adjustable • • • 2 speed •
Technical characteristics
Model Speed Abs. power Voltage Airflow Sound Weight at free (V) at free pressure discharge 50 Hz discharge level (r.p.m.) (W) (m3/h) (dB(A)) (kg)
CK-25 N 2250 40 230 250 50 1,9
CK-40 F 2350 70 230 360 55 2,7
CK-60 F VR 2475 160 230 625 59 4,7
VL 1740 96 415 54
Canopy size and extractor model recommendations CANOPY RECOMMENDED AIRFLOW EXTRACTION DUCT LENGTH (*)
SIZE (m3/h) 0 to 5 m 5 to 15 m 15 to 30 m
CK-40 F UP TO 60 cm 200-300 CK-25 N CK-35 N CK-50 CK-40 F ECO-500
CK-35 N CK-40 F CK-50 UP TO 90 cm 300-600 CK-40 F CK-50 ECO-500 CK-50 ECO-500 CK-60 F ECO-500 CK-60 F
(*) Expected with an installation with two 90° elbows.
Cooker Hoods
Whole House Systems
30 VENTURIA Extract system ensuring a continuous exhausting of air within residential homes through the extract grilles located in the ‘wet’ rooms (kitchens, toilets, bathrooms, etc) and air inlets located in the main rooms (living room, bedrooms, etc) allowing the input of fresh air.
Equipped with a centrifugal fan and fitted with a two speed, low energy consumption, 230V-50Hz motor, IP44, class B insulation.The Venturia extract system is designed for continuous operation.
Fitted with a two speed switch controlling the maximum airflow
The Venturia extract system ensures the continuous air renewal in residential houses through the extract grilles located in the ‘wet’ rooms (kitchen, toilets, bathrooms) and air inlets located in the main rooms (living room, bedrooms)
Continuous fresh air
Three anti vibration hangingcords enabling to hang the unit in the attic of a house or in false ceilings reducing theradiated noise
Remote location
• 4 exhaust valves of Ø 80 mm for toilets and bathrooms, removable by means of a quarter turn and fitted with two ring clamps allowing a quick and watertight installation of the ducts without tools and clamps. The exhaust valves of Ø 80 mm are regulated automatically: 2 at 15 m3/h and 2 at 30 m3/h.• Exhaust automatically regulated valves for kitchen of Ø 125 mm (45 m3/h and 135 m3/h), with 2 ring clamps for a fast installation.• Discharge port of Ø 125 mm allowing to expel the exhaust air to the outside.• Terminal box fitted• Two plastic covers to blockthe exhaust valves that are notoperating.
Standard version
Technical Model Voltage Power absorbed Absorbed
at free discharge current
(rpm) (W) (A)
VENTURIA-SF 230 65/24 0,3/0,2
VENTURIA 31
Whole House Systems
3 opening and closing flanges allowing the dismantling of the assembly motor-extractor without the need of disconnecting the ducts and the exhaust valves
Easy maintenance
Performance curves
260
202
266
Ø12531
2
265
Ø125
Ø80
Dimensions (mm)
Technical Model Voltage Power absorbed Absorbed
at free discharge current
(rpm) (W) (A)
VENTURIA-SF 230 65/24 0,3/0,2
Supplied with the VENTURIA Extract system, 2 exhaust valves designed for bathrooms of O 80mm, 1 exhaust valve for kitchens of Ø 125mm and a 2 speed switch
KIT VENTURIA
Accessories
Model Ø mm
Exhaust valve BOAP-80 80 Exhaust valve BOAP-125 125 Switch VMC 2 V
Whole House Systems
32 MINIFAN
MINIFAN is a whole house extract ventilation unit.The range is suitable for different types ofapplications and installations:• Single and multi-dwelling applications.• Either new building or refurbishment.• Small flats to large houses.• Low or high pressure drop systems.
The MINIFAN consists of 2 moulded plasticcomponents secured with clips to ensure perfectairtightness and to facilitate ease of dismantling.The MINIFAN can be installed in many configurations, it can be fixed either on the wall, in a cupboard, under the ceiling or in an attic. The duct work can run in cupboards, false ceilings, lofts, etc.
We recommend the use of our auto regulating valves in conjunction with the casing, to provide the correct rate of extraction and provide an efficient ventilation system.
The MINIFAN whole house ventilator is designed to improve the comfort and hygiene level in the home, with exhaust valves located in wet rooms: kitchen, bathrooms, toilets, etc. Fresh air is introduced through air inlets in the main rooms such as living room and bedrooms.
The MINIFAN is available in 3 standard model performances: LO, ST, HI.Each model is equipped with a 3 speedmotor.
The MINIFAN features:• 4 spigots in 125 mm.• 1 extract spigot in 125 mm.The unit body and fan motor plate are moulded from shock resistant ABS.Fan motor plate is moulded from heat resistant ABS . Highly durable polypropylene clip lock.An external rotor, class B insulation, IP44 protection.MINIFAN is suitable for continuous operation within temperatures of -20oC to +50oC.
MINIFAN 33
Whole House Systems
271
7183
83
303
326
Ø12
5
Ø125
Ø125
305
Dimensions (mm)
Performance curves
Technical characteristics Model Power supply Current Power Lw in (dB(A))
(A) (W) High speed Medium speed Low speed
MINIFAN LO 230/V~Hz/50Hz 0,29 65 55 * 52 * 43 *
MINIFAN ST 230/V~Hz/50Hz 0,37 80 61 * 56 * 45 *
MINIFAN HI 230/V~Hz/50Hz 0,45 95 62 * 58 * 41 *
* Sound power level radiated with all the spigots connected.
Air flow m3/h Without sleeve With sleeve With claw plasterboard in diameter Sleeve in diameter 125 mm 125 mm for wall installation for ceiling installation
15 BAR 15 BARJ 15 BARP 15
30 BAR 30 BARJ 30 BARP 30
45 BAR 45 BARJ 45 BARP 45
60 BAR 60 BARJ 60 BARP 60
Accessories
BARSelf-adjusting exhaust valves
ROOF OUTLETS Model Version CT 125 P Tulle Tile
CT 125 P Ard Slate
ECASelf-adjusting noise-attenuating Trickle Vent air inlets for installation in joinery elements
Air flow m3/h Model Colour 22 ECA 22 RA* white
30 ECA 30 RA* white
45 ECA 45 RA* white
*Air inlet with acoustic extension piece
Whole House Systems
34 AKOR The Akor Heat Recovery unit provides a balanced ventilation system with air renewal and heat recovery for domestic dwellings. The AKOR heat recovery unit incorporates an efficient cross flow heat exchanger and two direct drive centrifugal fans with 2-speed low power consumption class B, IP44 single phase 230V50Hz motors.
The casing is injection moulded from tough reinforced plastic.
The unit is designed for continuous operation.
Standard Versions
Option 1• 4 circular connection flanges 80 mm diameter for exhaust air from bathrooms, toilets and wet rooms.• 1 circular connection flange 125 mm diameter for exhaust air of the kitchen area.
Option 2
• 1 circular connection flange for exhaust air from bathrooms, WC’s and Utility rooms
Fibreglass thermal insulation Permanent drain to evacuatecondensation water
Easy maintenance and filtercleaning
Plate heat exchanger Efficient cross flow heatexchanger, manufacturedfrom polypropylene plates
All models incorporate inletand discharge circular ductconnection flanges withintegrated air seal
Option 2
Option 1
Technical characteristics Model Voltage Power absorbed Weight at free discharge
(V) (W) (kg)
AKOR-T37 230 115 15
AKOR-GD 230 270 16
* Sound pressure level measured at 1,5m, at the inlet side, in free field.
35
Dimensions (mm)
Connection for condensation drain
Insulation panel
External insulation
FRESH AIR
Interior airto be extracted
INPUT
OUTPUT
Characteristic curves
• Q = Air volume in, m3/hr and m3/s.• Pe = Static pressure in mmWG and Pa.• Dry air at 20oC and 760 mmHg.• Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
80
70
60
50
50 100 150 200 250
Eff
icie
ncy (%
)
Airflow (m3/h)
Heat recovery efficiency
Whole House Systems
Text in
Whole House Systems
36 AKOR
Air flow m3/h Without sleeve With sleeve With claw plasterboard in diameter Sleeve in diameter 125 mm 125 mm for wall installation for ceiling installation
15 BAR 15 BARJ 15 BARP 15
30 BAR 30 BARJ 30 BARP 30
45 BAR 45 BARJ 45 BARP 45
60 BAR 60 BARJ 60 BARP 60
Accessories
BARSelf-adjusting exhaust valves
ROOF OUTLETS Model Version CT 125 P Tulle Tile
CT 125 P Ard Slate
ECASelf-adjusting noise-attenuating Trickle Vent air inlets for installation in joinery elements
Air flow m3/h Model Colour 22 ECA 22 RA* white
30 ECA 30 RA* white
45 ECA 45 RA* white
*Air inlet with acoustic extension piece
Whole House Systems
37
Accessories
Model Diameter (mm) ABE-150/0.5M 150
CD intake grilleDesigned to introduce air into individual houses. It can be installed on a wall, ceiling or on straight or inclined ceiling tiles. Diam-eter 60 mm
BOAP/BOAC plastic extract grill
ABE defrosting unitPrevents the formation of ice from the con-densation on the interchanger plates in the air extract. Made from galvanized steel plate and supplied with polyethylene clips. It has a heat resistance of 500W and control thermostats.
ABE heating unitAllows the temperature of the blown air to be increased. It has a 500W power heating element and control thermostats.
Air inlet forfalse ceilingmounting
Air inlet, wall- mounted
Model Diameter (mm) BOAP 80 80
BOAC 80 80
BOAP 125 125
BOAC 125 125
Sound attenuatorLA 80LA 125
MRT Plastic connection for connecting 2 ducts of the same diameter
Model Diameter (mm) MRT 60 P 80
MRT 80 P 80
MRT 125 P 125 MRT 150 P 150
Duct fittings
Diameters Model A (mm) B (mm) C (mm) D (mm)
DERIV 80-80 P 80 80 80 DERIV 125-60-60-125 P 125 60 60 125 DERIV 125-60-60-60 P 125 60 60 60 DERIV 150-125-125 P 150 125 125
DERIV 150-60-60-125 P 150 60 60 125
Model Diameter (mm) ABE-150/0.5M 150
CT-150 extract roof cowl
Model Diameter (mm) CT 150P TILE 150
CT 150P SLATE 150
GP ISO insulated flexible duct
Model Diameter (mm) GP ISO 60 60
GP ISO 80 80
GP ISO 125 125
GP ISO 125 125
AKOR Plenum10 inlet spigots in 60 mm diameter.Outlet spigot in 150 mm diameter.5 covers.
AKOR switch(Extract/Input)2 extract positions with stop2 input positions with stop
38 TD-ECOWATT Series
Range of Low Profile Mixed flow fans with ball bearings and brushless DC motors, of high efficiency and low powerconsumption. Manufactured in plastic with a removable fan body, and rated as standard 90/260V-50/60Hz,IP44, speed controllable from 10% to 100%. Specially suitable for any kind of ventilationapplication, where the fan must operate continuously allowing a significant energy saving, or on those requiring a Demand Controlled Ventilaton System involving the use of other sensors or controls
The unique design of the sup-port bracket allows the motor and impeller assembly to be fitted or removed without dis-mantling the adjacent ducting
Easy maintainance
The low profile of the TD-ECOWATT fans makes them the most effective solution for installations where the space for installation is limited such as false ceilings.
Low profile
ClassicCentrifugal
CentrífugalIn-line
Ventilationcabinet
Mixed flowTD-ECOWATT
Design characteristics
160 250 350 500 800
Plastic housing • • • • • Plastic impeller • • • • • Insulation Class II II II II II
Non self resetable • • • • • thermal protection
Ball bearings • • • • •
Dimensions (mm)
303
188
176
97
100
80
9060
115
Domestic/ CommercialInline fans
TDM Series 39
Domestic/ CommercialInline fans
Place the impeller and motorFix the support bracket
Easy to mount
Connect the ductsCarry out the wiring connections
Technical characteristics Speed Maximum Maximum Airflow Maximum Sound Ø Weight power absorbed at free operating pressure Duct absorbed current discharge temperature level*
TD-MIXVENT (r.p.m.) (W) (A) (m3/h) (°C) (dB(A)) (mm) (kg)
TD-160/100 ECOWATT 2650 10 0,07 190 60 34 100 1,4
TD-250/100 ECOWATT 2400 22 0,17 275 60 35 100 2,0
TD-350/125 ECOWATT 2420 22 0,17 360 60 34 125 2,0
TD-500/150 ECOWATT 2600 48 0,35 580 60 36 150 2,7
TD-800/200 ECOWATT 2360 105 0,75 1030 60 38 200 4,9
Performance curves
– Q = Air volume in, m3/hr and m3/s.– Pe = Static pressure in mmWG and Pa.– Dry air at 20oC and 760 mmHg.– Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Elegant design harmonises with any environment
40 HV STYLVENT Series
Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase 230V- 50Hz motor. All the fans are class II insulation and IPX4 rated.The HV-STYLVENT series comprises 3 diameters: 150, 230 and 300 mm, including several operating options, making them ideallysuited for a wide range of general, commercial exhaust or supply ventilation applications.
To prevent air entry and prevent heat leakage when the extractor is not operating
Shutter
Extract or Supply operation
Reversible
CommercialWall/ Window
HV STYLVENT Series
41
HV-M versions Manually operated models via integral pull cord
• Single speed (HV-150M) or 2-speed (HV-230M and 300M) operation• Model 230 and 300 are reversible• Natural ventilation position (shutter open, fan off - except HV-150M)• Neon lights indicating the mode of operation
HV-150 M 2 Positions: Fan OFF, shutter closed Fan ON, working as air extract with shutter openHV-230 M 5 Positions:
HV-300 M 1 Fan stopped and shutter closed 2 Fan on high speed working as air extract with shutter open 3 Fan on low speed working as air extract with shutter open 4 Fan stopped and shutter open 5 Fan in reverse high speed supplying air in the room with shutter open
HV-A versions Automatic models operated via control unit CR
• Single speed (HV-150A) or 2-speed (HV-230A and 300A) operation• Model 230 and 300 are reversible• Natural ventilation position (shutter open, fan off)• Neon lights indicating the mode of operation
HV-150 A 3 Positions: Fan OFF, shutter closed Fan OFF, shutter open Fan ON, working as air extract
To operate all these functions use the accessory CR-150HV-230 A 5 Positions:
HV-300 A 1 Fan stopped and shutter closed 2 Fan on high speed working as air extract with shutter open 3 Fan on low speed working as air extract with shutter open 4 Fan stopped and shutter open 5 Fan in reverse high speed supplying air in the room with shutter open To operate all these functions use the accessory CR-300
Standard range
• Single-phase motor 230V50Hz with thermal overload protection• Single speed operation• Class II insulation• Model 230 and 300 are reversible with CR-150 control accessory• Automatic, thermally actuated shutter
HV-150 AE 2 Positions: OFF - Fan OFF, shutter closed ON - fan ON, working as air extract with shutter openHV-230 AE 3 positions (with CR-150 control accessory)
HV-300 AE OFF - Fan OFF/Shutter closed ON - Fan ON/shutter open Fan working as air extract/supplying air
REB-1R control Speed controller including a switch to reverse the airflow direction
HV-AE versions
CommercialWall/ Window
42 HV STYLVENT Series
Radio control range• Two speed operation• Natural ventilation position• All model are reversible• Automatic, thermally actuated shutter• Neon light mode of operation indication
HV-230 RC 6 Positions:
HV-300 RC 1 Fan stopped and shutter open 2 Fan stopped and shutter closed 3 Fan on high speed working as air extract with shutter open 4 Fan on reverse high speed supplying air in the room with shutter open 5 Fan on low speed working as air extract with shutter open 6 Fan in reverse low speed supplying air in the room with shutter open
HV-RC versions
Flush mounted version
HVE-230 AE 3 same positions as HV-230 AEHVE-230 A 5 same positions as HV-230 AHVE-230 RC 6 same positions as HV-230 RC
HVE versions
STYLVENT Product Summary – Operational Specifications
Model Flush Single Two Natural Pull Electrical accessories
Radio
mounted speed speed Reversible ventilation cord REB-1R CR-150 CR-300 control
HV-150 M • • HV-230 M • • • • HV-300 M • • • • HV-150 AE • • HV-230 AE • • • HV-300 AE • • • HV-150 A • • • HV-230 A • • • • HV-300 A • • • • HV-230 RC • • • • HV-300 RC • • • • HVE-230 AE • • • • HVE-230 A • • • • • HVE-230 RC • • • • • Maximum ambient operating temperature for all models: 45oC. One remote control can operate several HV.RC. In that case, the fans must be installed with a minimum distance of 1,5 meters between fans.
CommercialWall/ Window
Technical characteristics Model Speed Maximum Maximum Airflow rate (m3/h) SPL* at 3 m Weight
absorbed absorbed Extraction (dB(A))
power
current
High Low Intake High Low
(rpm) (W) (A) speed speed speed speed (kg)
HV-150 AE 1800 32 0,19 225 - - 39 - 2,0
HV-150 M 1800 32 0,19 225 - - 39 - 2,0
HV-150 A 1800 32 0,19 225 - - 39 - 2,0
HV-230 AE 1250 34 0,15 600 - 330 43 - 3,5
HVE-230 AE 1250 34 0,15 600 - 330 43 - 3,5
HV-230 M 1250 34 0,15 600 450 330 43 37 3,5
HV-230 A 1250 34 0,15 600 450 330 43 37 3,5
HVE-230 A 1250 34 0,15 600 450 330 43 37 3,5
HV-230 RC 1250 34 0,15 600 450 330 43 37 3,5
HVE-230 RC 1250 34 0,15 600 450 330 43 37 3,5
HV-300 AE 1150 68 0,30 1100 - 700 46 - 5,1
HV-300 M 1150 68 0,30 1100 750 700 46 38 5,1
HV-300 A 1150 68 0,30 1100 750 700 46 38 5,1
HV-300 RC 1150 68 0,30 1100 750 700 46 38 5,1
* SPL: Sound Pressure Level measured at 3 m.
G
F
B
C
E
Ø D
A
H
(no vidro)
Dimensions (mm) Model A B C ø D E F G H
Min Max Min Max Min Min
HV-150 230 251 109 187 190 3 25 22 160 150
HV-230 300 325 142 259 262 3 25 22 200 185
HV-300 368 403 150 327 330 3 25 22 230 220
163
173 182356
326
367
337
Dimensions of the HVE “flush mounted” version
CommercialWall/ Window
43
CommercialWall/ Window
44
Stage 1 External grilleOnce in position, the external grille is held bythree rubber plugs which allow the installer toassemble the interior section of the fan.
Installation in glass or panels from 3 to 25 mm thickness
Stage 2 Support frameTo enable easy mounting of the support frame, the holes are tapered and the fixing screws can be located depending on the glass/panel thickness:
3 mm< thickness<10 mm
10 mm<thickness<25 mm
Stage 3 Internal grilleFinally, place the lugs on the top of the support frame into the rectangular slots on the front grilleit into position.
The STYLVENT series of fans are designed for speed of installation in three easy stages.
For a wall mounted installation it is necessary to use the extended threaded rod set (see Installation Accessories) Installation on walls from 25 to 300 mm thick
Before installation, rods must be cut to 5mm less than the thickness of the wall. Cut a hole in the wall in accordance with the dimensions shown in the table (to right). Ensure that internal wall mounting surface is as smooth as possible.
On the interior of the wall, mark the fixing hole positions using the support plate as a template.
Fit the threaded rods to the external guard usingthe threaded sleeves. Place the external grille into position and hold in place with the rubber plugs.
Then, the installation follows the same stages as in the glass installation except for the supportframe installation, which has to be fixed using 2 or 4 screws (HV-150, HV-230 and HV-300 models respectively).
H
L
Ø D
Model ø D
Min Max H* L*
HV-150 187 190 117 121
HV-230 259 262 152 165
HV-300 327 330 322,5 357,3
* There are only two diagonal fixing holes for model HV-150
HV STYLVENT Series
45
CommercialWall/ Window
Threaded Rod setThreaded rods and sleeves for use when installing the HV fanson walls from 25 mm up to 300 mm thick
Installation accessories
Accessories
CR-150Control unit for HV-150 AFitted with:• On/off switch for fan operation. ( - )• On/Off switch for shutter operation• One single CR-150 unit can operate up to 5 HV-150 fans.
CR-300Control unit for HV-230 A,HV-300 A and HVE-230 A Fitted with:• A selector for the different modes of fan operation (0,••,•, )• A reversing switch to change the airflow direction ( , )• One single CR-300 unit can operate up to 5 HV-230 or 300 fans.
REB-1RSpeed controller including a switch to reverse the airflow direction.Only to be used with models HV-230 AE, HV-300 AE andHVE-230 AE Max 1A.
Connection cableA (7) core wire cable for the connec-tion of models HV-230 A andHV-300 A to the remote control unit CR-300. (Supplied on 10m rolls as standard)
Model Electrical supply IP Power Maximum Class Temperature Dimensions Frequency Voltage protection current (mm)
(Hz) (V) (VA) (A) L A H
REB-1R 50 220-240 IP-40 400 1 II ( ) 0-40°C 160 58 88
Control Unit CR-150 88 47 88
Control Unit CR-300 158 57 88
CommercialWall/ Window
46 HCM-N Series Range of axial flow fans designed to exhaust air directly to the outside. All the fans are manufactured from injection moulded plastic and fitted with automatic shutter and single phase 230V-50Hz, class B motor. All the fans are class II insulation and IPX4 rated.
Overpressure shutter
External shutter
Guards fitted at the inlet andoutlet of the fan to prevent the entry of any foreign objects
Safety guards
Installation
Mounting in glassMaximum diameter (3 to 6 mm)Cut hole diameter (mm)HCM-150 N 183 to 188HCM-180 N 220 to 225HCM-225 N 262 to 267
Mounting in wallsCut hole diameter (mm)HCM-150 N 183 to 188HCM-180 N 220 to 225HCM-225 N 262 to 267
Easy installationIn glass use two screws to fix the inner fan assembly to the outer part.For wall mounted installation using 4 screws to fix the winner fan assembly directly on the wall.
HCM-N Series 47
CommercialWall/ Window
Model ØA ØB C D E F
HCM-150 N 214 174 60 88 35 98
HCM-180 N 255 205 86 120 35 135
HCM-225 N 298 248 89 119 35 125
C
D
E
F
Ø B
Ø A
Dimensions (mm) Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight
absorbed (V) airflow pressure
power 50 Hz level*
(r.p.m.) (W) (m3/h) (dB(A)) (kg)
HCM-150 N 1900 25 230 400 40 0,9
HCM-180 N 2000 24,8 230 600 41 1,7
HCM-225 N 1700 40 230 900 45 1,8
* Sound pressure level measured at 1,5m, at the inlet side, in free field.
48 CADB-SSlimline Range of heat recovery units mounted with double skin galvanised sheet steel panels and internally lined with fireproof (M0) fibreglass insulation. They are supplied with a cross flow heat exchanger made of Aluminium with a maximum efficiency of 60%.
All models incorporate single phase direct drive forward curved centrifugal fans, an external IP55 terminal box and are supplied with four mounting feet with antivibration mounts to facilitate the installation and reduce noise transmission.
All models are fitted with inlet and discharge circular duct connection flanges with integrated rubber air seal.Supplied with two G4 grade filters.
MotorsCADB-010 2 speeds, Class B insulation, IP44.CADB-020 Speed controllable by voltage, Class F insulation, IP55. Electrical supply: Single phase 230V 50Hz.
Additional information Heat exchanger removable from the top panel. Filters removable from side panels.
Double skin galvanised sheet steel panels and internally lined with 25 mm thickness of fireproof (M0) fibreglass insulation
Low noise level
Anti-vibration mounts toreduce vibration and noisetransmission to the installation
Air tightness High efficiency filters
All models incorporate inletand discharge circular ductconnection flanges withintegrated rubber air seal
Two G4 grade filters, 90%efficiency and M3 fireresistance
CommercialHeat Recovery
CADB-S 49
CommercialHeat Recovery
All models are supplied withfour mounting feet to facilitate installation
Easy to mount
Permanent drain to removewcondensation water
Condensation drain
IP55 external terminal box
External weatherproof terminal box
Dimensions (mm)
Technical characteristics Model Fan Speed Motor Maximum Maximum Weight type power current drawn flow at 230V (r.p.m.) (W) (A) (m3/h) (kg)
CADB S 010 7/7 1100 2 x 184 2 x 1,5 1200 100
CADB S 020 9/9 1320 2 x 550 2 x 5,5 2000 130
CADB S 010 CADB S 020
A 1030 1100 B 950 1030 C 470 570 Ø D 315 400 E 230 260 F 245 290 G 1120 1220 H 1050 1120
J 970 1050
Characteristic curves The graphs are valid for air density of 1.2 kg/m 3 , with the tubing apparatus for intake and outtake.
Level of acoustic pressure measured in open field at 4m. Intake tubing. Lp in dB (A).
Level of acoustic power radiated at the intake duct. Lw in dB (A).
Level of acoustic power radiated at the outlet duct. Lw in dB (A).
CommercialHeat Recovery
50 CADB-SAccessories
ABEElectric heater batteriesOperationsDefrosting operation: To heat the outside fresh air before going through the heat recovery unit to avoid frost accumulation and sealing of the heat exchanger.Post heating operation: To increase the temperature of the supply air, after the heat exchanger.
AccessoriesKAAFlexible coupling
AFL AND AFR Filters
Electrical accessories
APCDischarge protection guards
Model Screen CADB S 010 APC-135
CADB S 020 APC-400
Model Frame support Spare +Filter Filter CADB S 010 AFL-010 AFR-010
CADB S 020 AFL-020 AFR-020
Model Flexible coupling CADB S 010 KAA-315
CADB S 020 KAA-400
PULSER controllerElectronic controller to regulate the heat outputfor single phase or two phase (200 - 415 V)electric heater battery in order to maintaina constant pre-selected temperature.Depending on the selected temperature, thecontroller pulses the entire power outputand uses a time-proportional control tomaintain that temperature.
PULSER-ADDSupplementary unit for slave control fromanother PULSER to control batteries withpower ratings superior to the PULSER capacity(3600W-230V).superior to the PULSERcapacity (3600W-230V).- Post heating operation: To increase the temperature of the supply air, after the heat exchanger.
TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.
Electrical heater battery accessoriesTo control the heater batteries.
DEFROSTING OPERATION POST HEATING OPERATION* Heat recovery Supply Diameter Power Heater Controller Duct External Controller Duct External Model (mm) (kW) type sensor potentiometer sensor potentiometer
CADB S 010 1~230V 315 3 ABE 315/3M PULSER TGK 310 TBI 10 PULSER TGK 330 TBI 30
CADB S 020 1~230V 400 5 ABE 400/5M PULSER + TGK 310 TBI 10 PULSER + TGK 330 TBI 30
PULSER ADD PULSER ADD
* Other control configurations are possible
51
CommercialHeat Recovery
TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.
PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.
TB-10Potentiometer mounted on the main board panel for setting temperature between -20 and +10oC. Used with the Pulser and a TGK-310 duct sensor to set the minimum air temperature before entering in the heat exchanger.
COM-2Speed switch for CADB S 010.
REB-10Single phase electronic speed controller for CADB S 020.
TB-30Potentiometer mounted on the main board panel for setting temperature between 0 and +30oC. Used with the Pulser and with a TGK-330 duct sensor to set the air temperature after the electric battery in post heating operation.
Acoustic accessories
SILSound attenuators to mount at the inlet and/or discharge of the heat recovery units
ØA ØB C D dB Attenuation
Model Attenuator (mm) (mm) (mm) (mm) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
CADB S 010 SIL 315 315 400 700 860 2 2,2 3,3 9 21,2 7,6 4,1 5,5
CADB S 020 SIL 400 400 500 700 860 1,8 3,1 4 9,5 13,7 5,6 0,4 5,9
CommercialVentilation
52 CADB-S Accessories
Model Frame Support Spare + Filter Filter
CADB S 010 AFL-010 AFR-010
CADB S 020 AFL-020 AFR-020
Mounting accessories
Electrical accessories: Electric heater batteries The heater battery operation must be enslaving to the fan operation. The installation must include a pressure switch to switch off the electric heater battery supplies in case of fan failure.ABEElectric heater batteriesOperations• Defrosting operation: To heat the outside fresh air before going through the heat recovery unit to avoid frost accumulation and sealing of the heat exchanger.• Post heating operation: To increase the temperature of the supply air, after the heat exchanger.
Electrical heater battery accessoriesTo control the heater batteries.
AFL and AFR Filters
Model Flexible coupling
CADB S 010 KAA-315
CADB S 020 KAA-400
KAAFlexible coupling
APCDischarge protection guards
Model Screen
CADB S 010 APC-315
CADB S 020 APC-400
PULSER controllerElectronic controller to regulate the heat outputfor single phase or two phase (200 - 415 V)electric heater battery in order to maintaina constant pre-selected temperature.Depending on the selected temperature, thecontroller pulses the entire power outputand uses a time-proportional control tomaintain that temperature.PULSER-ADDSupplementary unit for slave control fromanother PULSER to control batteries withpower ratings superior to the PULSER capacity(3600W-230V).superior to the PULSERcapacity (3600W-230V).
TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.
DEFROSTING OPERATION POST HEATING OPERATION* Heat recovery Supply Diameter Power Heater Controller Duct External Controller Duct External Model (mm) (kW) type sensor potentiometer sensor potentiometer
CADB S 010 1~230V 315 3 ABE 315/3M PULSER TGK 310 TBI 10 PULSER TGK 330 TBI 30
CADB S 020 1~230V 400 5 ABE 400/5M PULSER + TGK 310 TBI 10 PULSER + TGK 330 TBI 30
PULSER ADD PULSER ADD
* Other control configurations are possible
CADB-S Accessories
53
CommercialVentilation
Acoustic accessories
TBI-10Potentiometer mounted on the main board panel for set-ting temperature between -20 and +10oC. Used with the Pulser and a TGK-310 duct sensor to set the minimum air temperature before entering in the heat exchanger.
4.30 PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.
REB-10Potentiometer mounted on the main board panel for setting temperature between 0 and +30oC. Used with the Pulser and with a TGK-330 duct sensor to set the air temperature after the electric battery in post heating operation.
4.30 PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.
COM-2Speed switch for CADB S 010.
SILSound attenuators to mount at the inlet and/or discharge of the heat recovery units
ØA ØB C D dB Attenuation
Model Attenuator (mm) (mm) (mm) (mm) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
CADB S 010 SIL 315 315 400 700 860 2 2,2 3,3 9 21,2 7,6 4,1 5,5
CADB S 020 SIL 400 400 500 700 860 1,8 3,1 4 9,5 13,7 5,6 0,4 5,9
CommercialVentilationCooker Hoods
54 HS-600/900 • Decorative cooker hoods without motor• Illumination: two 40 W lamps• Professional type metal filters• Fan system speed controllable• Telescopic chimney
Fitted with control panel to adjust the speed of the fan.
Versions Stainless
HS-600 60 cm wide
HS-900 90 cm wide
Dimensions (mm)
GAR-190/150Flexible alumin-ium 190 x150 mm ducting with circular ends.3m long.
BA-50Aluminium adhesive connection tape to fix the accessories for theremote extraction installation.5 m long.
Flange-200Circular duct coupling. For fans CKB-800
Mixed flow in-line fan, type TD-800/200 N with an airflow performance of 800 m3/h.Speed controllable from the cooker hood and designed to be installed at any point of the duct.
55
CommercialVentilationCooker Hoods
Centrifugal roof extract fan with an airflowperformance of 800 m3/h. Controllable from the cooker hood and designed for roof mounted installations either in buildings or in houses.
Model Airflow Diameter Voltage Power Sound at free discharge pressure discharge tube level (m3/h) (mm) (V) (W) (dB (A))
TD-800 800 200 230 140 45
TH-800 800 200 230 140 52
Cooker hood without motor
Extractor fan
Cooker hood without motor
Extractor fan
Roof-mounted fan systemIn-Line fan system
TD-800
A canopy hood, with filter and controls, with a remote mounted duct fan provides enormous flexibility of installation.
A canopy hood, with filter and controls, with a remote mounted duct fan provides enormous flexibility of installation.
TH-800
Mounting Kit “H”To ease the installation of the decorative cooker hoods HS-600 and HS-900 regardless of the fan, a mounting kit with the required accessories is shown below:
56 HTB N STANDARD Series
High performance ceiling fans, silent, easy to install, three-speed control included.80, 100 and 140 cm diameter models.IP44, class B.
CommercialVentilationSweep Fans
Includes: three-speed control.Dimensions LxWxH (mm):68x42x113
ØA
ØB
D
C
ØEDimensions (mm)
Technical characteristics Voltage Power N° Maximum Air Sound Thermal Colour Speed control Weight 50Hz speeds speed flow pressure fuse switch level
Model (V) (W) (r.p.m.) (m3/h) (dB(A)) (Kg)
HTB-75 N 230 45 3 280 6.400 45 • White Included 4,8
HTB-90 N 230 60 3 240 8.650 46 • White Included 5,2
HTB-150 N 230 75 3 220 12.600 47 • White Included 8,2
Model Ø A Ø B C D
HTB-75 N 800 175 395 210
HTB-90 N 1000 175 395 210
HTB-150 N 1405 195 410 210
HTS STANDARD Series
57
CommercialVentilationSweep Fans
Silent ceiling fans, easy to install, metal bladesand body, three-speed control included.90 and 40 cm diameter models. Available inwhite colour paint or chromed finish type (CR).IP44, class B.
ØEDimensions (mm)
Includes; three-speed control.Dimensions LxWxH (mm):68x42x113
Technical characteristics
Voltage Power N° Maximum Air Sound Thermal Colour Speed control Weight 50Hz speeds speed flow pressure fuse switch level
Model (V) (W) (r.p.m.) (m3/h) (dB(A)) (Kg)
HTS-90 230 45 3 380 4.000 45 • White Included 5,2
HTS-140 230 50 3 226 6.000 46 • White Included 5,5
HTS-90 CR 230 45 3 380 4.000 45 • Chrome Included 5,2
HTS-140 CR 230 50 3 226 6.000 46 • Chrome Included 5,5
Model Ø A Ø B C D
HTS-90 905 175 395 210
HTS-140 1387 175 395 210
HTS-90 CR 905 175 395 210
HTS-140 CR 1387 175 395 210
Commercial Hand & Hair Dryers
58 SL Series S&P warm air hand dryers protected against vertical water splash.Fitted with thermal overload protection in the motor and the heating element. Motor Class II (*).(*) Aluminium and 2500 models, Class I
Technical characteristics Model Maximum Voltage Maximum Sound Weight Dimensions Casing On Off Colour
power (V) airflow pressure LxAxH material
absorbed level
(W) 50 Hz (m3/h) (dB(A)) (kg) (mm)
SL-2002 Automatic 1875 230 170 52 2.8 230x145x332 Polycarbonate Infra-red when hands are removed White
SL-2002 A Silver 1875 230 170 52 2.8 230x145x332 Polycarbonate Infra-red when hands are removed Silver
SL-2002 Aluminium 1875 230 170 52 3.8 230x145x332 Aluminium Infra-red when hands are removed White
SL-2002 1875 230 170 52 2.8 230x145x332 Polycarbonate Push button Run-On-Timer 45s White
SL-2500 2600 230 280 55 10 330x190x265 Aluminium Push button Run-On-Timer 50s White
Easy installation
SL-2002 A SILVER SL-2002 AUTOMATIC ALUMINIUM
SL-2002 AUTOMATIC SL-2002
SL-2500
SL-2002 AUTOMATIC / SL-2002 A SILVER
Automatic activation by means of an infrared
sensor • The unit switches off when the hands
are removed • Polycarbonate casing • Safety cut
out device to avoid continued function if exhaust
is blocked.
White (SL-2002 AUTOMATIC)
or SL-2002 A SILVER.
SL-2002 AUTOMATIC ALUMINIUM
Automatic activation by means of an infrared
sensor • The unit is switched off when the hands
are removed • Vandal resistant: Aluminium casing.
• Safety cut out device to avoid continued function
if exhaust is blocked.
White
SL-2500
Activated by means of Touch Control push
button. • Run-On-Timer of 50 seconds • Vandal
resistant casing: Aluminium casing • Two air
guide • Class I motor with self resetting thermal
protection.
SL-2002
Activated by means of a push button.
Run-On-Time of 45 seconds.
Polycarbonate casing.
COMET 59
Commercial Hand & Hair Dryers
Class II, fitted with thermal protection andadjustable airflow. The unit turns on and offautomatically.
Allowing the user to set therequired airflow
Adjustable airflow
When the unit is lifted or replaced back into the cradle
Easy to install
Such as toilets. hotel bath-rooms, gymnasiums chang-ing rooms, washrooms, etc
Once installed, the unit cannot be removed without special tools avoiding stealing or inappropriate use
Automatic switch-off/power-off
Many applications in commercial instalations
118 4 100
228
Dimensions (mm)
SL-2002
Technical characteristics Model Max. power Voltage On Off Weight Colour
at free (V)
discharge (kg)
(W) 50 Hz
COMET 800 230 Automatic Automatic 1.25 White
when lifted when replaced
Commercial Air Curtains
60 COR-S Series
The air curtains of the S range are designed to be installed in reduced spaces to create a barrier between two different areas. Because of the volume/power ratio, they also fulfi ll a purpose as a space heater.
The range S is made up of two models of 4 and 6 kW respectively, both with two heating powers, two speeds and ambient thermostat. They can also work at two speeds without heating.They create an effective barrier up to a distance of 1.5 m.The installation of this type of air curtain is recommended in cases such as kiosk windows, service windows that must be opened to assist the public, windows which, due to differences in temperature, have a tendency to steam up and make exterior vision diffi cult. Model COR-6-900 S includes a remote control unit.
Technical characteristics Voltage Heat Motor Speeds Airfl ow Outlet Maximum �ΔT Absorbed Thermal Ambient/ Remote Weight Colour (50 Hz) power power (m3/h) speed (m/s) (°C) current fuse Hot control at 0,05 m air Speed Speed Max. Power Min. Power
Model (V) (kW) (W) high low high low High s. Low s. High s. Low s. (A) (kg)
COR-4-900 S 230 2 / 4 30,5 2 409 316 4,4 3,4 30 38 15 20 18 • A / H 7,15 White RAL 9003
400V + N
COR-6-900 S 230V 3 phase 3 / 6 30,5 2 409 316 4,4 3,4 40 55 20 28 26/15/8,6 • A / H • 7,5 White RAL 9003
230V 3 single ph
Dimensions (mm)
APPLICATIONS OF COR SERIES AIR CURTAINSWhenever there is a loss of warm or cold air due to the opening of doors or windows.To install an air curtain not only creates a barrier between two environments reducing the loss of warm or cool air, but it also prevents insects from entering a room, specially in food preparation areas. All air curtains are fi tted with a special device that activates them when the door is opened.Air curtains are very useful in:Commercial applications: bars, restaurants, cinemas, shops, supermarkets, hypermarkets, workshops, hairdresser’s, theatres, outpatient departments, hospitals, exhibition hall, schools,churches, banks, gyms, changing rooms, pools, sports centres.Industrial applications: entrance goods door in warehouses, halls, cold stores, drying installations, greenhouses.
Air distance / speed
Power heating selector andthermostat COR-4-900 S
Installation height
900 Series
Technical characteristics Voltage Heat Motor Speeds Airfl ow Air output Maximum �ΔT Sound Absorbed Thermal Ambient Ambient Weight Colour (50 Hz) power power (m3/h) speed* (m/s) (°C) pressure current fuse thermostat Hot at 0,05 m level** connection air Speed Speed
Model (V) (kW) (W) High Med Low High Med Low (db(A)) (A) (kg)
COR-F-1000 N 230 100 2 1420 1090 10,5 48 0,5 A 15,2 White RAL 9003
COR-F-1500 N 230 200 2 2675 2060 10,5 50 0,8 A 20 White RAL 9003
COR-3,5-1000 N 230 3,5 100 3 1384 1070 640 10 9 11 18 48 15,5 • • A / H 15,8 White RAL 9003
COR-6-1000 N 3N 400 3 / 6 100 3 1384 1070 750 10 14 18 26 48 8,6 • • A / H 15,8 White RAL 9003
COR-9-1500 N 3N 400 4,5/ 9 200 3 2545 1960 1180 10 13 15 25 50 13 • • A / H 20,8 White RAL 9003
*Maximum speed. ** Measured at 3 m distance, at free air.
COR-N Series 61
Commercial Air Curtains
Air distance / speed
Power selector CR-6/9 NRemote control unit fi tted with the fan to con-trol up to 5 units of the same model in series.The combinations of the following models can be controlled with a single remote control:COR F-1000 N with COR-F-1500 NCOR-6-1000 N with COR-9-15000 N
Designed for wall application in commercial or industrial environments.Characteristics:High performance tangential propeller/impeller giving a low sound level.Can be installed in series. Extra low speed in those fans that need a higher output air temperature (warm air versions)
Installation height
Dimensions (mm)
1000 Series 1500 Series
Commercial Air Curtains
62 COR Series
Designed for wall mounting in commercial and industrial environments.Characteristics:• High performance tangential propeller/impeller giving a low sound level.• Ambient air version: COR-2F• Ambient/Warm air versions: COR-10
Dimensions (mm)
L
208
184
Model L DimensionCOR-2F 2148COR-10 2148Air distance / speedInstallation height
Technical characteristics Voltage Heat Motor Speeds Airflow Output Maximum Sound Absorbed Ambient Manual Ambient / Weight Colour 50/60Hz power power speed* � ΔT pressure current thermostat reset Hot (m/s) level** connection thermal air Model (V) (kW) (W) (m3/h) at 0,05 m (°C) (dB(A)) (A) fuse (kg)
COR-2F 1~230 160 2 2220 8 47,5 1 • • A 25 Ivory RAL 9002
COR-10 3~400+N 5 / 10 160 1 2150 8 13,5 47,5 15 • • A / H 28 Ivory RAL 9002
* Maximum speed. ** Measured at 3 m distance, at free air.
Control unit COR-2F Control unit COR-10
COR-IND M Series
63
Commercial Air Curtains
1390
405
315
Serie 1000
1970
405
315
Serie 1500
Dimensions (mm)
1390
405
315
Serie 1000
1970
405
315
Serie 1500
Designed for wall application in commercial or industrial environments.Characteristics:• High performance tangential impeller giving a low sound level.• Can be installed in series.• Available in ambient or ambient and hot air versions.• For installation at heights from 4 to 6 m.
Ease of installation Fitted with a hinged service cover to ease the wiring.
Technical characteristics
Installation heightAir distance / speed
Voltage Heat Motor Speeds Airflow Outlet Maximum �ΔT Sound Absorbed Thermal Ambient/ Weight Colour (50 Hz) power power (m3/h) speed* (m/s) (°C) pressure current fuse Hot at 0,05 m level** air Speed Max. Power Min. Power
Model (V) (kW) (W) high low High s. Low s. High s. Low s. (db(A)) (A) (kg)
COR-IND M 1000 F 230 267 2 3400 3037 12,84 55 1,2 • A 40 White RAL 9003
COR-IND M 1500 F 230 381 2 4849 4071 14,1 59 1,76 • A 50 White RAL 9003
COR-IND M 1000/18 3N 400 9 / 18 348 2 4955 4375 18.5 12,38 23,34 9,64 11,3 59 1,62 • A / H 45 White RAL 9003
*Maximum air speed **measured at 5m distance at free air
1000 Series
1500 Series
Accessories
CR-20 remote control unit
Remote control model Air curtain modelCR-20 COR-IND M 1000 F COR-IND M 1500 FCR-30 COR-IND M 1000/12 COR-IND M 1500/18Dimensions (mm) CR-20 / CR-30H 120 x W 80 x D 57 Each remote unit can control up to 5 units of the same model in series.The combinations of the following models can be controlled with a single remote control: COR-IND M-1000 F with COR-IND M-1500 F.
Accessories K SERIES
Accessories
64
PER-WBackdraft shutter
GRAAluminium guards
CXWorm drive clips
CM-130Backdraft shutter
CTCowel
GSAFlexiblealuminiumducting
PF-60Filter panel
CARBackdraft shutter
REBSingle phaseelectronic fan speed controlregulators
REGUL 2Two speedselectorswitch
CK-25 N CK-40 F CK-60 F
GSA-100 GSA-100 GSA-125
CX-80/125 CX-80/125 CX-125/215
PER-100 W PER-100 W PER-125 W
CAR-100 CAR-100 CAR-125
CM-130
CK-25 N CK-40 F CK-60 F
GRA-75 GRA-75 GRA-100
CT-125 CT-125 CT-125
PF-60 PF-60 PF-60
RWB-1N RWB-1N RWB-1N
RWB-1N E RWB-1N E RWB-1N E
REGUL-2
K Series
Are fitted with all the elements (extractor and accessories) needed to carry out a successful installation
CK kitchen Exhaust Fan Kits
Includes:1 CK-60 fan3m of GSA-100 flexible aluminium ducting2 Duct connectors CX-125/2151 Backdraft shutter CM-1301 two-speed switch REGUL-2
Includes:1 CK-40 fan3m of GSA-100 flexible aluminium ducting2 Duct connectors CX-80-1251 Backdraft shutter CM-130
Kit CK-40 F Kit CK-60 F
GP GP “COQUE” Series
GRX Series
GP-ISO Series GPX Series
Flame retardant PVC: M1Bending radius: 0,6 x ØWorking temperature: from -18oC to 75oC
WORM DRIVE DUCT CLIPS (CX)
Dimensions Ø Equivalent Length
Model (mm) diameter (mm) (m)
GR 90 x 45 90 x 45 80 6
GR 135 x 70 135 x 70 125 6
GRX 90 x 45 90 x 4580 6
GRX 135 x 70 135 x 70 125 6
Flame retardant PVC: M1Bending radius: 0,6 x ØWorking temperature: from -18oC to 75oCGrey PVC rectangular flexible ducting supplied reinforced with polyester and supplied in 6 m compressed lengths for dwelling ventilation applications.
Dimensions Ø Equivalent Length
Model (mm) diameter (mm) (m)
GR 90 x 45 90 x 45 80 6
GR 135 x 70 135 x 70 125 6
GRX 90 x 45 90 x 4580 6
GRX 135 x 70 135 x 70 125 6
Worm drive flexible duct connection clips of various diameters. Suitable to fix flexible ducting to accessories.
Model Diameters (mm)
CX-80/125 From 80 to 125
CX-125/215 From 125 to 215
CX-250 250
CX-315 315
ALUMINIUM DUCT TAPE (BA-50)
Adhesive aluminium duct tape with 5 m lengths.
PLASTIC CIRCULAR BACK DRAFT SHUTTERS (CM-130)
Small diameter plastic back draft shutter to be installed within a circular duct to prevent back draft of air when the fans are switched off.
Model Diameters (mm)
CM-130 113/122 - 118/127
65
Accessories
Ø118Ø127
Ø122
Ø11
3
Ø133 136
CIRCULAR INLET/OUTLET PROTECTION GUARDS (APC)
protection guards for direct connection to the inlet/outlet fan flange connector
Model ØA B
APC-125 125 232
APC-160 160 252
APC-200 200 275
APC-250 250 304
APC-315 315 342
APC-355 355 365
APC-400 400 391
APC-450 450 420
APC-500 500 449
APC-560 560 483
APC-630 630 524
APC-710 710 570
APC-800 800 622
60°
B
ØA
70 100
CIRCULAR BACK DRAFT SHUTTERS (CAR)
66
Back draft shutters to be installed within circular ducting to prevent back draft of air when the fans are switched off.
Model ØD L L1 L2
CAR-100 100 80 32
CAR-125 125 100 42
CAR-150 150 120 52
CAR-160 160 120 52
CAR-200 200 140 62
CAR-250 250 140 62
CAR-315 315 140 62 45
CAR-355 352 160 198
CAR-400 397 160 223
FLEXIBLE CONNECTOR (MSO)
Circular flexible connectors for fans designed for ventilation applications.
Model Ø(mm)
MSO 125 125
MSO 160 160
MSO 200 200
MSO 250 250
MSO 315 315
MSO 355 355
Model Ø(mm)
MSO 400 400
MSO 450 450
MSO 500 500
MSO 560 560
MSO 630 630
MSO 710 710
CIRCULAR FLEXIBLE CONNECTOR (KAA)
Circular flexible connectors designed for smoke extract fans in fire conditions and certified F400 120.
Model Ø(mm)
KAA-120 112
KAA-140 125
KAA-160 160
KAA-180 180
KAA-200 200
KAA-225 225
KAA-250 250
KAA-280 280
Model Ø(mm)
KAA-315 315
KAA-355 355
KAA-400 400
KAA-450 450
KAA-500 500
KAA-560 560
KAA-630 630
KAA-710 710
METALLIC ROOF TERMINAL COWL (CT)
Designed for circular duct connection, the CT roof terminal kit enable air discharge or supply through a flat or pitched roof.
Model A B C Ø D E F G H I J Weight
(kg)
CT-125 54 200 250 125 70 500 400 –
CT-150 65 248 300 150 70 500 400 – –
CT-200 100 333 400 200 85 600 600 160 500 500 8
CT-250 100 333 400 250 85 600 600 160 500 500 8
CT-315 112 420 500 315 85 600 600 140 500 750 9
CT-355 200 550 660 355 150 900 750 225 600 750 17
CT-400 200 550 660 400 150 900 750 225 600 750 17
CT-450 200 550 660 450 150 900 750 225 600 750 17
CT-500 245 650 850 500 160 1200 1000 215 780 997 34
CT-630 320 780 1000 630 160 1200 1000 215 780 997 36 Model Discharge Supply
CTM 125 350 165
CTM 150 425 245
CTM 200 900 600
CTM 250 1050 850
CTM 315 1800 1100
CTM 355 2600 1700
CTM 400 3000 2100
CTM 450 3600 2600
CTM 500 4700 3500
CTM 630 8000 4500
USE: Recommended air volumes
(Pressure drop 20 Pa)
Accessories
67
PLASTIC ROOF TERMINAL COWL (CTP)
Designed for circular duct connection, the CTP roof terminal kit enable air discharge or supply through a flat or pitched roof.
Model A B C Ø D E F G H Weight
(kg)
CTP 125 72 203 280 125 80 500 400 140 3,5
CTP 150 72 203 280 150 80 500 400 140 3,5
CTP 160 72 203 280 160 80 500 400 140 3,5
Model Discharge Supply
CTP 125 320 170
CTP 150 320 210
CTP 160 320 210
DUCT CONNECTOR FOR ROOF TERMINAL COWL (BROCHAL)
Duct connector enabling to fit the flexible duct just before the roof terminal cowl.
Models:Brochal 125Brochal 150
ROOF EXTERNAL FRESH AIR GRILLE
External fresh air grille for dwelling ventilation application with heat recovery system.
WALL EXTERNAL FRESH AIR GRILLE
External fresh air grille for dwelling ventilation application with heat recovery system.
150 mm
150 mm
ALUMINIUM GRILLE (GRA)
Aluminium externally / internally mounted discharge / supply air grilles.
Model External Grille dimensions area A B
GRA-70 130 x 130 100 x 100
GRA-100 165 x 165 125 x 125
GRA-150 190 x 190 150 x 150
GRA-200 210 x 210 165 x 165
GRA-300 240 x 240 200 x 200
ALUMINIUM INTERNAL GRILLE (GRI)
Extract louvre grilles manufactured from aluminium and finished with an epoxy polyester paint coating.
Model Available nominal dimensions
GRI-125 125 x 125
GRI-200 200 x 200
GRI-250 250 x 250
GRI-300 300 x 300
GRI-450 450 x 450
TERMINAL CONNECTOR (RP) FOR GRI INTERNAL GRILLE
The RP plenums are manufactured from galvanised sheet steel. Six diameters are available for corresponding GRI grilles.
Model Available nominal dimensions
GRI-125 125 x 125
GRI-200 200 x 200
GRI-250 250 x 250
GRI-300 300 x 300
GRI-450 450 x 450
200
250
125
450
0.180.15
0.125
0.100.080.070.060.05
0.0450.04
0.030.025
0.015
0.02
0.0050.006
0.01
0.035
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 9 10
Q(m3/h)
4000
3000
2000
1500
1000900800700
Air volume and air speed comparison (m/s)
Open surface (m2)
speed (m/s)
Accessories
Accessories
68
ØA
ØB
L1
ØC
Ø
E
L
GCI – CIRCULAR SUPPLY/EXHAUST GRILLES
Air diffuser extract/supply grilles manufactured from aluminium and finished with epoxy-polyester paint coating.
Model A B C Net free area Min. air Max. air
(m2) volume volume
GCI-160 140 250 200 0,0086 70 275
GCI-200 190 300 250 0,0200 120 500
GCI-250 240 350 300 0,0326 200 800
GCI-315 290 400 350 0,0460 275 1100
GCI-350 340 450 400 0,0550 350 1200
GCI-400 390 500 450 0,0702 400 1500
VR mounting accessory for GCI circular grilles
Mounting support to facilitate the installation of the GCI circular grilles and connection to ducting.
Flexible
ducting
INTERIOR AIR EXHAUST VALVE (BOC)
Metallic air exhaust valves for dwelling and commercial applications. All models offer an adjustable central valve to regulate the airflow. They can be used in heating, air conditioning and ventilation system.
Model Ø A Ø B Ø C Ø D Ø E L
BOC-100 100 125 74 75 137 47
BOC-125 125 150 98 100 161 49
BOC-160 160 185 128 149 218 60
BOC-200 200 225 157 157 248 75
INTERIOR AIR EXHAUST VALVE (BOR)
White polystyrene air exhaust valves for dwelling and commercial applications. All models offer an adjustable central valve to regulate the airflow. They can be used in heating, air conditioning and ventilation system.
Duct diameter Duct Plasterboard Paving slab and thick
Ø (mm) mounting valve mounting valve wall mounting valve
Model Model Model
80 BOR 80 BOR 80 P BOR 80 D
100 BOR 100 BOR 100 P BOR 100 D
125 BOR 125 BOR 125 P BOR 125 D
150 BOR 150 BOR 150 P BOR 150 D
160 BOR 160 BOR 160 P BOR 160 D
200 BOR 200 BOR 200 P BOR 200 D
Connector dimensions (mm)
Model Air flow Ø A Ø A1 Ø B Ø B1 C H
BOR 80 from 10 to 100 m3/h 78 77 99 110 100 275
BOR 100 from 15 to 160 m3/h 89 98 130 129 100 250
BOR 125 from 25 to 200 m3/h 122 120 155 155 130 275
BOR 150 from 30 to 250 m3/h 148 145 195 195 100 250
BOR 160 from 30 to 250 m3/h 158 155 195 195 100 250
BOR 200 from 55 to 330 m3/h 198 195 235 235 100 250
Characteristics and dimensions (mm)
3-claw mounting connector
Ø A
C
Ø B
Duct mounting connector with rubber seal
Ø A1 Ø B1
Paving slab and thick wall mounting connector
Ø A
Ø B
HH
69
Accessories
BOAP 80
BOAE 80 BOAC 80
BOAP 125 BOAE 125 BOAC 125
BOAP 80 60
���60
�
A
A
A
A
60
���120
PLASTIC REDUCER (RED)
Model Diameters (mm)
RED-100/80 100-80
RED-125/100 125-100
RED-150/125 150-125
RED 160/125 P 160-125
RED 200/160 P 200-160
RED-250/200 250-200
Plastic sections for the connection of two ducts of different diameters.
PLASTIC DERIVATION (DERIV)
Model
DERIV 80/80 P
DERIV 125-60-60-125 P
DERIV 125-60-60-60 P
DERIV 150-125-125 P
DERIV 150-60-60-125 P
Plastic sections for the connection/adaptation of different duct diameters.
PLASTIC GRILLE (GR-100)
Plastic interior or exterior mounting air discharge grilles. Designed for direct connection to 100 mm diameter ducting.
WALL KIT
Wall kit with fixed grille for use with EDM-80N, EDM-100, DÉCOR-100 and SILENT-100.The kit includes a plastic external grille and a telescopic duct wall liner. The kit allows the fan to be installed in walls of 20-42 mm thickness.
PLASTIC CIRCULAR DUCT JOINING PIECE (MRT)
Plastic pieces allowing the connection of two ducts of the same diameter.
PLASTIC EXHAUST VALVES (BOC)
Plastic exhaust valves manufactured from injection
moulded white polypropylene plastic.
• BOCP are supplied with 3-claw mounting connector
suitable for plasterboard and ceiling tiles installation.
• BOAE are supplied with a large mounting connector
suitable for paving slabs and thick walls
Model Ø Connector type
(mm)
BOCP 80 80 Ht 100 - 3-claw mounting connector
BOCP 125 125 Ht 100 -3-claw mounting connector
BOC 80 80 Ht 275 - Thick wall mounting connector
BOC 125 125 Ht 275 -Thick wall mounting connector
BOC 80 80 Ht 300 - Bent mounting connector
BOC 125 125 Ht 440 - Bent mounting connector
Dimensions (mm)
A 80 129mm125 172mm
Wiring DiagramsGENERAL WIRING DIAGRAMS: Domestic Fans
70MODELS: DV; VM; H CONTROLLED BY INTEGRAL PULLCORD OR SENSOR
230V~50Hz
EXCLUDES SELV 12V FANS AND SYSTEM PRODUCTS
MODELS: T; R; CR; CT; HM; HT CONTROLLED BY REMOTE SWITCHED LIVE
230V~50Hz
CONTROLLED BY REMOTE SWITCHMODELS: EC: C
230V~50Hz
eg. SILENT-100 12V DECOR-100 12V EDM-100 12V
* Also available: CT/1214 R to give adjustable run-on time
SELV TRANSFORMER
230V~50Hz
*
SELV (Safety Extra Low Voltage)
71
Wiring DiagramsHV-STYLVENT options
Fig 1
Fig 3
Fig 2
Fig 1: STYLVENT 150 and STYLVENT 230 & 300 (Pullcord models)Fig 2: STYLVENT 230 and 300 extract/intakeFig 3: STYLVENT 230 and 300 extract or intake only
HV STYLVENT HV-150 M; HV-230 M; HV-300
HV STYLVENT HV-150 M; HV-230 RC; HV-300 RC
1. Fan Stopped; Shutter open
2. Fan Stopped; Shutter closed
3. Fan on High Speed; Shutter open
4. Fan in Reverse (High Speed); Shutter open
5. Fan on Low Speed; Shutter open
6. Fan in Reverse (Low Speed); Shutter open
6
Live
HV STYLVENT; HV-150 A; HV-230 A; HV-300 A
Fig 1
Fig 3
Fig 2
1. Extraction only
2. Intake only
3. Extraction and intake (reversible) with the CRS-150
Wiring DiagramsTD ECOWATT options
72
Fig 1a
TD-ECOWATT 160/100
Fig 1a TD ECOWATT Connection directly to a 230V supplyFig 1b TD ECOWATT Connection to available speed controllerFig 2a TD ECOWATT Connection to a 230V supplyFig 2b TD ECOWATT Variable speed controllerFig 3a TD ECOWATT Connection to other external sensorsFig 3b TD ECOWATT Connection to other external sensorsFig 3c TD ECOWATT Connection to other external sensorsFig 4 TD ECOWATT Directly to a 230V supplyFig 5 TD ECOWATT Variable speed controller
Fig 1b
Fig 2a Fig 2b
TD-ECOWATT 160/100
TD-ECOWATT 250/100; 350/125
Fig 4
TD-ECOWATT 160/100
Fig 3a Fig 3b
Fig 3b
TD-ECOWATT 500/150; 800/200
Fig 5