Thorlabs’ new Dual Channel PM300 Series Optical Power Meterand PM300E Series Power and Energy Meter offer many feauresnot found in handheld devices. They are ideal for precise opticalmeasurements, laser and photodiode characterization, lifecyclemeasurements and many more applications in the lab and on themanufacturing floor. The dual channel design enables differentialand ratiometric measurements. Intuitive manual operation with thelarge graphics display, compatibility to conventional photodiodes,and excellent remote capabilities enable easy system integration.
The PM300 is compatible with all Thorlabs S100 SeriesPhotodiode Sensors (two channels) and S200 Series ThermalSensors (one channel) and allows the connection of unamplifiedanode or cathode grounded photodiodes with up to 10mAphotocurrent and thermal elements with up to 100mV outputvoltage. The PM300E additionally offers energy measurements with all Thorlabs ES100 and ES200 Series Energy Sensors (bothchannels) and dual-channel measurements with the S200 SeriesThermal Sensors as well. Both the PM300 and PM300E Series aresold as a single benchtop device with the sensors ordered separately.It can be combined with any of our power meter sensor heads, oruser-supplied photodiodes that provide a maximum 10mA output.The PM300E Series is additionally compatible with all ES100 andES200 Series Pyroelectric Energy Sensors.
Functionality
The calibrated sensors connect via two sub-D connectors on therear panel, which also provides two analog high bandwidth outputsto allow monitoring of each channel, plus the programmable analogoutput. Optional user-supplied photodiodes connect via two BNCinputs on the front panel, which feature switchable bandwidth anda programmable bias voltage. The input can be switched betweenthe front and rear connectors. The additional BNC output is gain-and-function programmable. It provides an analog voltageproportional to the output of one of the channels or as a differenceor ratio of the two power meter channels. The measurementresolution is 16 bit for all power ranges. The PM300 and PM300ESeries are controlled locally via the front panel, which features alarge 240x128 pixel LCD display, or remotely via USB 2.0.
Common Console Features■ Programmable Channels: Monitor, Difference, Ratio,
Math Functions, Linear and Log Values, Attenuation■ USB 2.0 Interface■ Large Graphics Display: 240 x 128 pixels ■ Compatible Sensors: S100 (Photodiode), S200
(Thermal) Power Meter Sensors, and CommonPhotodiodes
■ Programmable Responsivity for Connection ofPhotodiodes & Thermal Sensors
PM300E Additional Features■ Continuous and Single-Shot Energy Measurement of
Pulsed Laser Sources■ Adjustable Trigger Threshold, Beam Diameter, and
Wavelength■ Display of Energy in J and J/cm2, Average Power in W
and W/cm2, Repetition Rate in Hz■ Externally Triggered Power and Energy Measurements
PM300 Benchtop ConsoleSensors Sold Separately
PM300 Series Dual Channel Power and Energy Meters
PhotodiodeSensorSee page 958
IntegratingSpheres Sensor See page 959
Slim Sensor See page 958
Thermal Sensors See page 960
Pyroelectric Sensors See page 961
Post and PostHolders SoldSeparately
PM300E Benchtop ConsoleSample Display Screen
2_PowerMeters 946-961.qxd.P 7/13/07 8:53 AM Page 956
Laser Lab Instruments
957www.thorlabs.com
ITEM# $ £ € RMB DESCRIPTION
PM300 $ 1,800.00 £ 1,134.00 € 1.674,00 ¥ 17,190.00 Dual Channel Power Meter Console
PM300E $ 2,200.00 £ 1,386.00 € 2.046,00 ¥ 21,010.00 Dual Channel Power and Energy Meter Console
CAL-PM300 $ 200.00 £ 126.00 € 186,00 ¥ 1,910.00 Calibration Service for the PM300 Series Consoles
PM300 Benchtop Power Meter Without Sensor
Compatible With All Thorlabs’ Sensors. Please Refer to the Following 4 Pages.
SpecificationsPower Meter Model PM300 PM300EDetector Compatibility Photodiode Sensors S100 Series Photodiode Sensors S100 Series
Thermal Sensors S200 Series Thermal Sensors S200 SeriesPhotodiodes (Max 10mA) Pyroelectric Sensors ES100/ES200 Series
Thermopiles (Max 100mV) Photodiodes (Max 10mA)Thermopiles (Max 100mV)
Display Graphical LCD 240 x 128 pixels (3.7" x 2.4")
Display Format Numerical, Bar Graph, Trend Graph
Dimensions (H x W x D) Overall 220 x 122 x 325 mm
Photodiode Input CH1 & CH2 CH1 & CH2Units W, dBm, A W, dBm, A, W/cm2
Measurement Ranges 7 Decades; 10nA to 10mA 6 Decades; 100nA to 10mARanges Selectable in W, Sensor Dependent Ranges Selectable in W, Sensor Dependent
Display Resolution 1pA per Responsivity Value (A/W) 10pA per Responsivity Value (A/W)
Accuracy ±0.2% Full Scale (1µA - 10mA) ±0.2% Full Scale (1µA - 10mA)±0.5% Full Scale (10nA - 100nA) ±0.5% Full Scale (100nA)
Polarity AG, CG
Bias Voltage 0 to -10V (CG), 0 to +10V (AG)
Thermopile Power Input 1CH1 ONLY CH1 & CH2Units W, dBm, (V) W, dBm, W/cm2, V
Measurement Ranges 4 Decades; 100µV to 100mV 3 Decades; 1mV to 100mVRanges Selectable in W, Sensor Dependent Ranges Selectable in W, Sensor Dependent
Display Resolution 100nV per Responsivity Value (V/W) 1µV per Responsivity Value (V/W)
Accuracy ±0.5% Full Scale (1mV to 100mV range) ±0.5% Full Scale
Pyroelectric Energy Input N/A CH1 & CH2Units N/A J, J/cm2, W
Measurement Ranges N/A 4 Decades; 100mV to 100VRanges Selectable in J, Sensor Dependent
Display Resolution N/A 100µV per Responsivity Value (V/J)
Accuracy N/A ± 0.5% Full Scale
Maximum Repetition Rate N/A 5 kHz
External TriggerConnector N/A BNC Rear
Programmable Analog OutputSignal Selectable: CH1, CH2, CH1-CH2, CH1/CH2
Voltage Range 0 to ±10V; Programmable Gain and Offset
Bandwidth Up to 500Hz, Dependent on Sensor and Settings
Analog Outputs
Signal CH1, CH2 Amplified Input Signal
Voltage Range 0 to ±10V
Bandwidth Up to 100kHz, Dependent on Sensor and Settings
PM300 Series Dual Channel Power and Energy Meters
1 Channel 2 can be used for a second photodiode based power meter sensor. Please refer to the following 4 pages.
Detectors
Power Meters
CCD Cameras
Optical Chopper
Beam Profliers & Extensions Sets
Spectrometers
Temperature Controller & Shutter
Filter Wheels
2_PowerMeters 946-961.qxd.P 7/20/07 11:14 AM Page 957