Guanri Repeater
Repeater Local Test
User Manual
Guanri Telecom-Tech(Shenzhen) Co., Ltd.3/F, Building R3-B, High Technology Industrial Park,
Shenzhen, China
Tel: 86-755-26520688
Fax: 86-755-26520869
-
7/29/2019 Lacal Test Manual
2/25
2
1 Connect the computer to theMonitor Port of the Monitor Board
with a serial cable.
2 Open the Repeater Test software
on the computer.
3 Select the correct COM Number.
-
7/29/2019 Lacal Test Manual
3/25
3
PLL Setup (Generally, we need not to change the default values which have
been set correctly according to the specified repeater by the testing engineers
in the Guanri manufacture center.):
Operation Steps:
Repeater Operation-PLL Set (the password is: hwthwt)
-
7/29/2019 Lacal Test Manual
4/25
4
Notes: Firstly, we must select the correct repeater type. In thewindow above,64 stands for the 200KHz frequency adjusting step.
-
7/29/2019 Lacal Test Manual
5/25
5
5 Parameters Setup
Repeater Operation-Parameters Setup
-
7/29/2019 Lacal Test Manual
6/25
6
Then display this dialog
-
7/29/2019 Lacal Test Manual
7/25
7
Frequency Parameters Setup
Firstly, select the correct repeater type in the selective frame(displayed in blue in the window above).Secondly, set specified working channels(or working channels and shift
channels).
-
7/29/2019 Lacal Test Manual
8/25
8
UL/DL PA switch states and Attenuation Setup
Click on Other Parameters Setup, the window below will appear.
-
7/29/2019 Lacal Test Manual
9/25
9
Communications Parameters Setup
Click on Communications Parameters. See the window below.Set correct Numbers of the center station and select the correct
communication mode.
-
7/29/2019 Lacal Test Manual
10/25
10
display the Output powers
Firstly, check the real-time value of the output power:
-
7/29/2019 Lacal Test Manual
11/25
11
So the window below will be displayed on the computer
-
7/29/2019 Lacal Test Manual
12/25
12
Then the window below will be displayed on the computer
From the window, we can get all the values and the states displayed:
Especially DL/UL PA Power show we the signal output power of the repeater. If the output
power is not ideal, we can set the UL and UL Attenuation whose maximum values both are 31 dB
to change the output power. Take note that if you adjust the DL Attenuation, you need to adjust
the UL Attenuation too for keeping the balance.
-
7/29/2019 Lacal Test Manual
13/25
13
Check the alarm states
-
7/29/2019 Lacal Test Manual
14/25
14
Firstly, enable all alarms switch
-
7/29/2019 Lacal Test Manual
15/25
15
Then, check the alarms states
Operations: Parameters Query-Alarms Query
-
7/29/2019 Lacal Test Manual
16/25
16
Then the alarm status window display
-
7/29/2019 Lacal Test Manual
17/25
17
And we can adjust some alarm thresholds to change some alarm states.
Operations: Repeater Operation-Parameters Setup-Alarm Threshold Setup
-
7/29/2019 Lacal Test Manual
18/25
18
We can Query the real-time parameters of the repeater
Firstly select Parameters Query Real_time Parameters Query
-
7/29/2019 Lacal Test Manual
19/25
19
Then display the Real-time Parameters Query window
-
7/29/2019 Lacal Test Manual
20/25
20
And we can adjust some alarm thresholds to change some alarm states.
Operations: Repeater Operation-Parameters Setup-Alarm Threshold
Setup
-
7/29/2019 Lacal Test Manual
21/25
21
Adjust the analog values adjustment to change the values
displayed in the following window
-
7/29/2019 Lacal Test Manual
22/25
22
Adjust the values adjustment
Operations: Repeater Operation-Analogs Value Adjusting
Notes: Forward Adjust
means making the
relating values
becoming bigger just in
displaying, but it cant
change the realworking values. And
Reverse Adjust means
making the relating
values less in displaying.
-
7/29/2019 Lacal Test Manual
23/25
23
There are some information which has been set as
default of the repeater in the software, we need not
to change them because they do not effect the
working states of the repeater.
After all the parameters have been set correctly, the
repeater can work normally.
-
7/29/2019 Lacal Test Manual
24/25
24
ServiceYour satisfaction is our priority. Offering a quick and
effective technical support, we always put the customer first.
Please dont hesitate to contact us by the following ways if you
have any questions.
Guanri Telecom-Tech(Shenzhen) Co., Ltd.Address: 3/F, Building R3-B, High-Tech Industrial Park,
Shenzhen, P.R.C.
Post code: 518057
Tel.: 86-755-26712354, 26520688
Fax: 86-755-26548582
E-mail: [email protected]
Website: http://www.guanri.com.cn
mailto:[email protected]://www.guanri.com.cn/http://www.guanri.com.cn/mailto:[email protected] -
7/29/2019 Lacal Test Manual
25/25
25
Thank You!